You are on page 1of 2

Drift Check Combinations

Rule Dead Live Roof Live Wind Seismic


1 1.20 1.60 0.50
2 1.20 0.50 0.50 1.00
3 1.20 0.50 1.00
4 0.90 1.00
5 0.90 1.00

Ultimate Strength Design Combinations


Rule Dead Live Roof Live Wind Seismic
1 1.40
2 1.20 1.60 0.50
3 1.20 0.50 1.60
4 1.20 1.60 0.50
5 1.20 0.50 0.50 1.00
6 0.90 1.00
7 1.68 0.50 1.00
8 1.38 1.00
9 0.42 1.00

Allowable Stress Design Combinations


Rule Dead Live Roof Live Wind Seismic
1 1.00
2 1.00 1.00
3 1.00 1.00
4 1.00 0.75 0.75
5 1.00 0.60
6 1.00 0.714

Service Load Combinations for Foundation


Rule Dead Live Roof Live Wind Seismic
1 1.00 1.00 1.00
2 1.00 0.75 0.75 0.45
3 1.00 0.75 0.75 0.536
4 0.60 0.60
5 0.60 0.714
6 1.00 1.00 0.60
7 1.00 1.00 0.714

Basic Load Combinations


Rule Dead Live Roof Live Wind Seismic
1 1.40
2 1.20 1.60 0.50
3 1.20 0.50 1.60
4 1.20 1.60 0.50
5 1.20 0.50 0.50 1.00
6 1.20 0.50 1.00
7 0.90 1.00
8 0.90 1.00

You might also like