You are on page 1of 26

1703-2C1610

Commercial Air Conditioners 2017/2018

Air Cooled Chillers & AC Fan Coil Units

Commercial Air Conditioner Division


Midea Group
Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China

Postal code: 528311


Midea CAC After-service Application Midea CAC News Application

Tel: +86-757-26338346 Fax: +86-757-22390205

cac.midea.com global.midea.com

Note: Product specifications change from time to time as product improvements and

iOS Version Android Version iOS Version developments are released and may vary from those in this document.
Midea CAC
Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation There are three production bases: Shunde, Chongqing and Hefei.
and air conditioning solutions. Midea CAC has continued with the tradition of innovation upon which it was founded, and MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU.
emerged as a global leader in the HVAC industry. A strong drive for advancement has created a groundbreaking R&D MCAC Chongqing: 14 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled Screw/Scroll Chillers,
department that has placed Midea CAC at the forefront of a competitive field. Through these independent efforts and joint and AHU/FCU.
cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide. MCAC Hefei: 11 product lines focusing on VRF, Chillers, and Heat Pump Water Heaters.

2016 Strategic alliance between Midea and Italy's Clivet


2015 JV with Carrier in China in chiller field, launched the unitary all DC inverter type Aqua Mini Chiller
2014 Launched the Super series chiller, which is adopting H shape condenser
2013 Launched the Power Series with low ambient temperature cooling function
Midea Company Midea CAC 2012 Formed Midea-Carrier JV.Company in India and HK
Introduction Introduction 2010 Built the 3rd manufacturing base in Hefei, Launched the Power Series with V shape condenser and tub-in-tube evaporator
2008 Launched the Power Series with V shape condenser and plate type evaporator
2006 Launched the first VSD centrifugal chiller
2004 Acquired MGRE entered the chiller industry
2001 Cooperated with Copeland to develop the digital scroll VRF system
2000 Developed the first inverter VRF with Toshiba
1999 Entered the CAC field
Introduction

Introduction
Introduction
Midea air-cooled scroll chiller adopts air as the cooling/heating source and water as the cooling/heating medium
to cooling/heating the indoor ambient temperatures through the indoor terminals (AHUs/FCUs). They are
Contents
environment friendly products for the R410A refrigerant adopted, which does no harm to ozone layer. The chiller
system always works at the most high efficiency stage thanks to the advanced technology. Also, the air cooled
chiller system has a lower initial investment cost than water cooled system. It does not require cooling tower,
condenser water pump and associated condenser water chemical treatment system.

Midea air-cooled scroll chillers are divided to Tempo Power series and Tempo Super series according to their
structure and capacity. Single unit’s capacity range is from 30kW to 250kW. Modular design concept makes the
application from single unit to multiple units. Maximum combination air-cooled scroll system’s cooling capacity
ups to 2080kW. 09 Aqua Tempo Power Series
Midea fan coil units are divided to ceiling exposed type, ceiling concealed type, wall-mounted type and
floor-standing type according to their structure design and installation method. The air volume ranges from
150CFM to 2200CFM (255m3/h~3740m3/h). It is a highly versatile product suitable for hospitals, office buildings, 19 Aqua Tempo Super Series
hotels, airports and various other applications.

31 Fan Coil Units

03 04
Reference Projects Hotels & Resorts

Sports
Reference Projects

Reference Projects
Sheraton Bandara Resort Hotel(Five Star)
Country: Indonesia
City: Jakarta
2015 Youth Olympic Games-Dinamp Arena Outdoor Units: Air-cooled screw chiller
Country: Georgia Total Capacity: 1,050RT
City: Tbilisi Completion Year: 2011
Outdoor Units: Air-cooled modular chiller
Indoor Units FCU & AHU
Complex
Total Capacity: 780kW Grand Comfort is the largest material market in middle Asia, the total area is 55,000 square meters. Midea CAC provided 21 air-cooled
power and super modular chillers for the project.
The total capacity is up to 5,780kW.

2015 Youth Olympic Games-Volleyball Arena


Country: Georgia
City: Tbilisi
Outdoor Units: Air-cooled modular chiller
Indoor Units FCU & AHU
Total Capacity: 400kW

Transportation

Grand Comfort Material Market


Jakarta International Airport
Country: Kyrgyzstan
Country: Indonesia Outdoor Units: Air-cooled modular chiller
City: Jakarta Indoor Units FCU & AHU
Outdoor Units: Air-cooled screw chiller Total Capacity: 5,780kW
Indoor Units FCU & AHU Completion Year: 2015
Total Capacity: 1,400kW

05 06
Industry
Reference Projects

Reference Projects
Harvey Nichols Edinburgh
Country: UK
City: Edinburgh
Outdoor Units: Air-cooled modular chiller
Indoor Units FCU
Total Capacity: 255HP

Zetes Power Station


Country: Turkey
City: Zonguldak
Outdoor Units: Precision A/C, VRF, Air-cooled
modular chiller
Indoor Units Duct & Cassette, AHU
Total Capacity: 500HP

Education

City Mall
Country: Tanzania
City: Dar es Salaam
Outdoor Units: Air-cooled modular chiller
Indoor Units FCU & AHU
Total Capacity: 1,560kW
Komar University
Country: Iraq
City: Sulaymaniyah
Outdoor Units: Air-cooled serew & scroll chiller
Indoor Units FCU & AHU
Total Capacity: 2,350kW

07 08
Aqua Tempo Power

Aqua Tempo Power


Air Cooled Scroll Chiller Product Lineup
Aqua Tempo Power Capacity (kW) 30 65 130 200 250

Midea Aqua Tempo Power chillers adopt V shape heat exchanger and single unit’s capacity from 30kW to 250kW. Appearance

They are divided to PS & PS-LA series according to their operation ambient temperature range and inner components.
Series

PS-LA series are products with low ambient temperature cooling function .
50Hz PS (F/D) / / / / /

50Hz PS-LA(F/D) / / / / /

PS: Standard Power Series


PS-LA: Power Series with low ambient temperature cooling function
F: Product adopted fixed speed scroll compressor
D: Product adopted digital scroll compressor

09 10
Features Advanced technology
Digital scroll technology
Wide application range
The digital scroll compressor utilizes axial compliant sealing technology to precisely adjust the axial motion range of the stator
The basic models with cooling capacity ranging from 30kW to 250kW, combination model’s maximum capacity
scroll pan. And there is an additional connecting by-pass between the suction inlet and the pressure bore at the floating sealing
ups to 2000kW.
point of axial stator.
Max 8 modules

PWM valve
Provides 40 million times the average service life of PWM
Discharge solenoid valves, making sure the long life of compressor.
Fixed Scroll Guarantees high efficiency by applying axial-compliant
250kW 250kW 2000kW
Suction sealing technology.
Freely combine with fan coil units and air handling units. Project owners may choose the best types according to their design
Inverter EMC Regulation Digital Scroll System
taste (for interior) or functional needs.
Orbiting Scroll Ampere
5th
7th
Cassette type 11th
Aqua Tempo Power

Aqua Tempo Power


Air handling units 13th
Provides 10% to 100% stepless capacity output to
17th
precisely control room temperature.
19th 0 1 2 3 4 5
Less electromagnetic interference, no EMC problem. EMW

Floor standing Operation Principle of Digital Scroll Compressor

Duct type
When the PWM solenoid valve is open, the pressure in the pressure bore is
released. The pressure in the compression bore is higher than that top of
the stator, then the stator axis of the compressor will move upward a little.
Celling & Floor
So high pressure bore and low pressure inlet is connected and the unload-
Wall mounted ing is achieved.
Wide operation ambient temperature range When the PWM solenoid valve is closed, two stators engage to achieve an
For the Aqua Tempo Power chillers with low ambient temperature cooling function, the running ambient temperature down airtight state and loading functionality.
to -10°C both in cooling and heating. The compressor can adjust the ratio of ON to OFF freely to control the refrig-
46˚C 27˚C -10˚C 27˚C erant output of the compressor.
46˚C 24˚C
COOLING

HEATING

High reliability in high ambient temperatures is guaranteed by the low pressure design of the compressor motor.
-10˚C -10˚C

Effectively cools the compressor motor by suction gas.


Creates stronger resistance to the compressor liquid hammer.
Discharge
Wide range of outlet water temperature Provides strong reliability in high ambient temperatures.
For the Aqua Tempo Power chillers with low ambient temperature cooling function, the lowest outlet temperature in cooling
Suction
mode is 0°C.
0°C 17°C 22°C 50°C
Compressor motor

COOLING MODE HEATING MODE

11 12
High performance heat exchanger Flexible installation
Built-in hydraulic module
Reduce air resistance
MGCSL-F (D) 30W/RN1are equipped with a hydraulic module integrated into
the unit chassis, limiting the installation to straight-forward operations like
connection of the power supply, the water supply and the air distribution
terminals.
Original design
New design High efficiency inner-threaded pipe, Hydrophilic fins + inner-threaded pipes Individual hydraulic module optional
enhance heat transfer.
Individual hydraulic module compatible with cooling capacity of 65kW and 130kw is optional. Water box, expansion water tank,
two water pumps are built in the hydraulic box. The integral structure design saves you much installation labor and cost.
The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance heat
exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures HM/II-65S
HM/II-130S
a longer coil service life.

Back-up functions
Aqua Tempo Power

Aqua Tempo Power


Easy control
In a combination system, if one module failed, other modules can be back-up instead of the failed one for continuing operation.
Touch key wire controller as standard accessory to control the chillers.

Master Slave Master Slave

Compliance with ErP directive


30kW and 65kW products are compliance with ErP directive, including both PS series and PS-LA series. The seasonal space heating
energy efficiency classes for 30kW models are A rated and 65kW models are A+ rated.

Remote control functions for convenient operation.


There are ON/OFF, Heat/Cool and Alarm terminals ports on PCB, connect switches from these terminal ports and remote
control functions can be easily realized.

Note: When use the remote control function, the wired controller will be invalid for ON/OFF and mode selection.

13 14
Specifications
50Hz PS & PS-LA series (Fixed type) 50Hz PS & PS-LA series (Digital type)
MGC-F30W/RN1(B) MGB-F65W/RN1(B) MGB-F130W/RN1(B) MGB-F200W/RN1(B) MGC-D30W/RN1(B) MGB-D65W/RN1(B)
Model MGBL-F250W/RN1 Model MGCL-D30W/RN1 MGBL-D65W/RN1
MGCL-F30W/RN1 MGBL-F65W/RN1 MGBL-F130W/RN1 MGBL-F200W/RN1
Power supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 Power supply V/Ph/Hz 380-415/3/50 380-415/3/50

Capacity kW 30 65 130 185 250 Capacity kW 30 65

Input kW 10.0 20.4 40.8 63.0 78.3 Cooling 1


Input kW 10.0 20.4
Cooling1

EER 3.00 3.18 3.18 2.93 3.19 EER 3.00 3.18

Capacity kW 32 69 138 200 270 Capacity kW 32 69

Heating2 Input kW 9.8 21.5 43.0 61.0 80.0 Heating2 Input kW 9.8 21.5

COP 3.27 3.21 3.21 3.27 3.38 COP 3.27 3.21

Max. running current A 21.1 54.5 109 150 200 Max. running current A 21.1 54.5

Type Finned tube Finned tube Finned tube Finned tube Finned tube Type Digital Scroll+Fixed Scroll Digital Scroll+Fixed Scroll
Compressor Compressor
Quantity Pieces 2 2 4 6 8 Quantity Pieces 2 3

Type Fin-coil Fin-coil Fin-coil Fin-coil Fin-coil Type Finned tube Finned tube
Aqua Tempo Power

Aqua Tempo Power


Fan motor type AC Motor AC Motor AC Motor AC Motor AC Motor Fan motor type AC Motor AC Motor
Air side heat exchanger Air side heat exchanger
Quantity of fan motor Pieces 1 2 4 6 8 Quantity of fan motor Pieces 1 2

Air flow m /h
3
12,000 24,000 48,000 72,000 96,000 Air flow m /h
3
12,000 24,000

Type Double-pipe Shell-tube Shell-tube Shell-tube Shell-tube Type Double-pipe Shell-tube

Water pressure drop kPa 60 15 25 30 40 Water pressure drop kPa 60 15


Water side heat exchanger Water side heat exchanger
Volume L 10 42 64 90 131 Volume L 10 42

Water flow volume m3/h 5.2 11.2 22.4 31.8 43 Water flow volume m3/h 5.2 11.2

Type R410A R410A R410A R410A R410A Type R410A R410A

Refrigerant Charged volume kg 7.0 14.0 28.0 42.0 60.0 Refrigerant Charged volume kg 7.0 14.0

Throttle type EXV EXV EXV EXV EXV+Capillary Throttle type EXV EXV

Sound pressure level3 dB(A) 65 67 70 74 74 Sound pressure level3 dB(A) 65 67

Unit net dimension(D×H×W) mm 1,514×1,865×841 2,000×1,880×900 2,000×2,090×1,685 2,850×2,110×2,000 3800×2130×2000 Unit net dimension(D×H×W) mm 1,514×1,865×841 2,000×1,880×900

Packing dimension(D×H×W) mm 1,590×2,065×995 2,106×2,090×998 2,090×2,240×1,755 2,980×2,260×2,135 3900×2200×2100 Packing dimension(D×H×W) mm 1,590×2,065×995 2,106×2,090×998

Net/ Gross weight kg 375/400 580/650 1,150/1,270 1730/2,000 2,450/2,600 Net/Gross weight kg 375/400 610/680

Pipe connections Water inlet/outlet mm DN40 DN100 DN65 DN80 DN100 Pipe connections Water inlet/outlet mm DN40 DN100

Controller Wired controller Wired controller Wired controller Wired controller Wired controller Controller Wired controller Wired controller

Ambient temperature Cooling °C 10~46 10~46 10~46 10~46 10~46 Cooling °C 10~46 10~46
Ambient temperature range
range
Heating °C -10~24 -10~24 -10~24 -10~24 -10~24 Heating °C -10~24 -10~24

Ambient temperature Cooling °C -10~46 -10~46 -10~46 -10~46 -10~46 Cooling °C -10~46 -10~46
Ambient temperature range4
range4
Heating °C -10~24 -10~24 -10~24 -10~24 -10~24 Heating °C -10~24 -10~24

Water outlet temperature Cooling °C 5~17 5~17 5~17 5~17 5~17 Cooling °C 5~17 5~17
Water outlet temperature
range range
Heating °C 40~50 40~50 40~50 40~50 40~50 Heating °C 40~50 40~50

Cooling °C 0~17 0~17


Water outlet temperature Cooling °C 0~17 0~17 0~17 0~17 0~17 Water outlet temperature
range5 range5
Heating °C 22~50 22~50 22~50 22~50 22~50 Heating °C 22~50 22~50

1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB. 1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB.
2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB. 2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.
3. 1m away in open field. 3. 1m away in open field.
4. The date is for PS-LA series. 4. The date is for PS-LA series.
5.The data is for low water outlet temperature function 5.The data is for low water outlet temperature function.
15 16
Dimensions (Unit:mm)
30kW module 200kW module

C
B
C

E
F B

D F A
E
Aqua Tempo Power

Aqua Tempo Power


D A
250kW module
65kW module

C
D F C B

E
D F A
E
A

Model A B C D E F

130kW module MGB-F(D)30W/RN1(B)


1514 841 1865 115 315 172
MGBL-F(D)30W/RN1

MGB-F(D)65W/RN1(B)
2000 900 1880 350 506 1420
MGBL-F(D)65W/RN1

MGB-F130W/RN1(B)
2000 1685 2080 350 506 1420
MGBL-F130W/RN1

MGB-F200W/RN1(B)
2850 2000 2110 347 506 2156
C MGBL-F200W/RN1
D F
B
MGBL-F250W/RN1 3800 2000 2130 1235 573 2156

E
A

17 18
Aqua Tempo Super

Aqua Tempo Super


Air Cooled Scroll Chiller Product Lineup
Aqua Tempo Super Capacity (kW) 35 65 80 130

Appearance
Midea Aqua Tempo Super chillers adopt H shape heat exchanger at air side and single unit’s capacity from 35kW to 130kW. They

are all products with low ambient temperature cooling function. Super chillers SS-LA series accordings to its water side heat

exchanger and inner components. SS series adopt tube-in-tube or shell-tube heat exchanger. Series

SS

SS-LA

SS:Super series adopt tube-in-tube or shell-tube heat exchanger


SS-LA:Super series with low ambient temperature cooling function based on SS series

19 20
Features Advanced technology
Wide application range H shape high performance heat exchanger
4 basic models with cooling capacity ranging from 35kW to130kW, combination model’s maximum capacity ups to 2080kW.
The chillers adopt new structure design, H shape condenser, 360°air intake, increase the heat exchanging area, efficiently enhance
the heat exchange efficiency, and decrease the covering area.
130kW 130kW 2080kW
Max 16 modules

Freely combine with fan oil units and air handling units. Home owners may choose the best types according to their functional
needs.

Newly designed air profile


Big air flow lower noise 1

Cassette type
360° Condenser coil
High efficiency 2
Aqua Tempo Super

Aqua Tempo Super


Air handling units Wall mounted

Removable panel
Easy to maintain 3

Duct type
Transportation hole
Easy to install 4
5 Multi folder frame
Nice and strong
Wide range of ambient temperature

46˚C 27˚C -15˚C 27˚C


H shape condenser adopts inner grooved copper tube and hydrophilic aluminum foil, greatly improve the heat exchange
46˚C 24˚C
efficiency.
COOLING

HEATING

-10˚C -15˚C Inner grooved copper tube Hydrophilic aluminum foil

Wide range of outlet water temperature

0°C 17°C 25°C 50°C

COOLING MODE HEATING MODE

21 22
EXV for more precisely flow control High reliability
Patented liquid distribution components to maximize performance and minimize defrost impact. Alternative cycle duty operation
500 steps EXV plus capillary for stable and accurate gas flow control. In one combination module, all slave units operate as alternative in cycle duty to keep equal running time, realize higher stability,
Fast respond resulting in higher efficiency and improved reliability. better reliability and longer lifespan.
For example, five modules combination, no.1 is master unit, others are slave units.
100%

75%

50%
1 1 1
2 3 3 3
25%
4 2 4 2
5 4 5
0% 5
Back-up functions
In a combination system, if one module failed, other modules can be back-up instead of the failed one for continuing operation.

Tube-in-tube & shell-tube heat exchanger


Master Slave

Chilled water inlet


Refrigerant inlet
Aqua Tempo Super

Aqua Tempo Super


Water dead zone
Flat baffle plate
Master Slave

Chilled water outlet


Refrigerant outlet

Helical baffle

Reliable protections
Multiple protections are adopted to ensure system stable running.
For shell-tube heat exchanger, the module adopts the new helical baffle design to avoid the rectangular place of water dead
zone, greatly improve the heat exchange efficiency.

High/low pressure Power phases Evaporator low temperature System anti-freezing Frequently ON/OFF
protection of Over-current Air discharge temperature System high temperature Water flow protection Sensor malfunction
sequence protection protection in cooling protection in winter protection of compressor
compressor protection protection of compressor protection protection
of compresor

23 24
Intelligent defrosting technology Individual hydronic module optional
Model alternative defrosting technology ensures little fluctuation on water temperature. Individual hydronic module compatible with cooling capacity of 65kW and 130kW is optional.
Manual defrosting program is available for service purpose. Water box, expansion water tank, two water pumps are built in the hydronic box. The integral structure design saves you much
installation labor and cost.
Midea Fast Defrosting Traditional defrosting

HM/II-65S
HM/II-130S
Heating capacity

T min Time
saving
Easy control
Time
7 minutes less! Touch key wire controller as standard accessory to control the chillers.

Flexible installation
Compact structure design
Super power chiller adopts compact structure design, light weight, easy for transportation and installation.

Big air flow but low noise fan


Big torque high efficiency fan motor
Aqua Tempo Super

Aqua Tempo Super


1

Inner grooved copper tube


Capacity & efficiency increase

EXV 7
500 steps Remote control functions for convenient operation
Control box
Easy to maintain
Helical baffle There are ON/OFF, Heat/Cool and Alarm terminals ports on PCB, connect switches from these terminal ports and remote control
Efficiency increase 10% functions can be easily realized.
6
2
Multi folder frame
Low vibration. 5
Durable and stable Scroll compressor
3 High efficiency
4 Low noise

Built-in hydronic module


For SP series, built-in hydraulic module products are available. The modules are fully integrated and built-in expansion tank, plate
heat exchanger, water circulating pump, etc. It saves you much installation space and cost.

Hydraulic Module
Note: When use the remote control function, the wired controller will be invalid for ON/OFF and mode selection.

25 26
SS series & SS-LA series Dimensions (Unit:mm)
Model
MC-SS35/RN1 MC-SS65/RN1 MC-SS80/RN1 MC-SS130/RN1 25/35kW module 65/80kW module
MC-SS35/RN1L MC-SS65/RN1L MC-SS80/RN1L MC-SS130/RN1L

Power supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50

Capacity kW 35 65 80 130

Cooling 1
Input kW 10.0 20.4 20.4 20.4

EER 3.04 3.19 3.10 3.07

Capacity kW 37 69 85 138 D F

C
Heating 2
Input kW 9.8 21.5 21.5 21.5

COP 3.27 3.21 3.21 3.21

Max. running current A 27.0 54.5 65 109

E
Type Fixed Scroll Fixed Scroll Fixed Scroll Fixed Scroll

E
Compressor
Quantity Pieces 1 1 2 2
D F
Type Finned tube Finned tube Finned tube Finned tube

Air side heat Fan motor type AC Motor AC Motor AC Motor AC Motor
exchanger Qualitity of fan motor Pieces 1 2 2 2

Air flow m3/h 13,500 27,000 27,000 50,000

B
Type Double-pipe Shell-tube Shell-tube Shell-tube

Water side heat Water pressure drop kPa 55 30 30 40


exchanger Volume L 10 35 47.5 60 A
Aqua Tempo Super

Aqua Tempo Super


Water flow volume m3/h 6 11.2 13.8 22.4 A
Type R410A R410A R410A R410A

Refrigerant
130kW module
Charged volume kg 5.4 11.5 13 21

Throttle type EXV EXV EXV EXV

Sound pressurer level3 dB(A) 65 67 67 68

Unit net dimension(D×H×W) mm 1,020×1,770×980 2,000×1,770×960 2,000×1,770×960 2,200×2,060×1,120

Packing dimension(D×H×W) mm 1,070×1,900×1,030 2,090×1,890×1,030 2,090×1,890×1,030 2,250×2,200×1,180

B
C
Net/Gross weight kg 320/330 530/590 645/710 950/1,020

Pipe connections Water inlet/outlet mm DN40 DN65 DN65 DN65

Controller Wired controller Wired controller Wired controller Wired controller D F


A
Ambient temperature Cooling °C 10~46 10~46 10~46 10~46

E
range Heating -15~24 -15~24 -15~24 -15~24
°C

Ambient temperature Cooling °C -10~46 -10~46 -10~46 -10~46


range4 Model A B C D E F
Heating °C -15~24 -15~24 -15~24 -15~24

Water outlet Cooling °C 5~17 5~17 5~17 5~17


MC-SS35/RN1(L) 1020 980 1770 237 250 400
temperature range
Heating °C 45~50 45~50 45~50 45~50

Water outlet Cooling °C 0~17 0~17 0~17 0~17 MC-SS65/RN1(L)


2000 960 1770 336 506 1420
temperature range5 MC-SS80/RN1(L)
Heating °C 25~50 25~50 25~50 25~50

1. Cooling: Chilled water inlet/outlet temperature: 12/7°C, outdoor ambient temperature 35°C DB. MC-SS130/RN1(L) 2200 1120 2060 390 347 1420
2. Heating: Warm water inlet/outlet temperature: 40/45°C, outdoor ambient temperature 7°C DB/6°C WB.
3. 1m away in open field.
4. The date is for SS-LA series .
5.The data is for low water outlet temperature function

27 28
Control System Standard features/options
Wired controller
Model KJRM-120D/BMK-E(standard) KJR-120A/MBTE(optional) Description Standard features Options

Appearance
Hermetic scroll compressor

Compressor crankcase heaters

Compressor circuit breakers

Main Functions Parameter setting and display. Parameter setting and display. Compressor overload protection
Real time clock control. Real time clock control.
Manual reset. Manual reset.
Remote control icon display. Remote control icon display. Condenser fan-direct drive, axial type
Hysteresis temperature setting. Hysteresis temperature setting.
Touch key operation Weekly timing function.
Condenser fan(Metal)
Applied Range Aqua Tempo Power & Aqua Tempo Super Aqua Tempo Power & Aqua Tempo Super

Condenser fan guard


Max. connection PCBs 16 16

Compatible Gateway Modbus & Lon Works Lon Works Condenser motor circuit breakers

Modbus gateway can be customized by adding X, Y, E ports on wired controller KJRM-120D/BMK-E. It can connect Max. 16 wired Aluminum fins condenser coils
controllers and each controller can control Max. 16 units.
Low pressure switch
Aqua Tempo Super

Aqua Tempo Super


Max. 16 (P Q E) Max. 16 units High pressure switch

Modbus
Wired controller KJRM-120D/BMK-E
(X Y E)
gateway
(P Q E) Max. 16 units Wired controller KJR-120A/MBTE
Modbus

gateway BMS gateway(Lonworks)


(X Y E)

MODBUS gateway

Computer Remote control input

LonWorks gateway Alarm signal output

LonWorks gateway controls the central A/C to facilitate the building management system (BMS). Main settings of LonWorks:
Anti-freezing protection
operation Mode, outlet water temperature, hysteresis temperature and clear alarm.
There are two connection methods for LonWorks: Over-load protection

Connection 1 Connection 2 Power phases sequence protection


LSQ-LONWORKS LSQ-LONWORKS
Anti-corrosion fins
Air-cooled Scroll units:Max. 16 units
Air-cooled Scroll units: Max. 16 units Water flow switch

RS485(P Q E)
LONWORKS RS485(P Q E) RS485(P Q E) LONWORKS
Three phase power protector
NET WORK NET WORK

65kW hydraulic module

BMS SYSTEM 130kW hydraulic module


BMS SYSTEM

29 30
Fan Coil Units
Fan Coil Units

Fan Coil Units Nomenclature


M K T3 - 2200 E G100
Midea Fan Coil Units have ceiling exposed type, ceiling concealed type, wall-mounted type and floor-standing type. The air

volume ranges from 150CFM to 2200CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and

various other applications.


Static Pressure
G12: 12Pa; G:30: 30Pa; G50: 50Pa;
G70: 70Pa; G100: 100Pa;

Fuction Code

Nominal Air Volume (CFM)

Type Code

Chilled Fan Coil Unit

Midea

31 32
Product Lineup
2-Pipe FCUs

High Static
4-Way Cassette Duct
Pressure Duct

4-way Casstte

200

300

400

500

600

750

800

850 Duct

950

1000

Fan Coil Units


Fan Coil Units

1200

1400

1500

1600

1800

2000
High Static Pressure Duct
2200

Note:
The standard power supply for all fan coil units is 220V-240V/50Hz; 208-230V/60Hz can be customized for all fan coil units.

33 34
2-Pipe 4-Way Cassette Specifications

Model Non-AEH MKA-600R MKA-750R MKA-850R

Power supply V/Ph/Hz 220-240/1/50


Air flow (H/M/L) m3/h 1000/850/720 1250/1060/900 1400/1190/1010
CFM 590/500/420 740/620/530 820/700/590

4-way panel Cooling Capacity (H/M/L)


Water flow rate
kW
L/h
5.7/4.73/3.96
980
7/5.62/4.72
1204
7.27/6.46/5.71
1250
Water pressure drop kPa 23.8 25.2 27
Heating Capacity (H/M/L) kW 9.66/7.72/6.27 11.55/9.24/7.51 12.42/9.93/8.07
Water pressure drop kPa 16.4 11.8 14.6
Power input (H/M/L) W 125/84/74 130/102/93 150/124/106

Sound pressure level (H/M/L) dB(A) 45/41/36 46/42/37 47/43/38


Fan motor Type Low noise 3-speed fan motor

Stylish Panel with Large Airflow Outlet Fan


Quantity
Type
1
Centrifugal, forward-curved blades
Quantity 1
Coil Row 2
4-way air supply panel is standard for 4-way cassette. Max. working pressure MPa 1.6
Diameter mm Φ7
Panel Net dimensions (W×H×D) mm 950×45×950
Packing size (W×H×D) mm 1035×90×1035
Net weight kg 6
Gross weight kg 9
Various Accessories Selections Body Net dimensions (W×H×D)
Packing size (W×H×D)
mm
mm
840×230×840
900×260×900
840×230×840
900×260×900
840×300×840
900×330×900
Net weight kg 25 25 30.5
Gross weight kg 30 30 36.2
Safe factory-installed electric heater is optional. Pipe Water inlet/outlet pipe inch RC3/4
Extended drainage pan is optional. connections Drain pipe mm ODΦ32

Wireless controller is standard, and wired controller is optional.


Non-AEH MKA-950R MKA-1200R MKA-1500R
Model
Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 1600/1360/1150 2000/1700/1440 2550/2170/1840
CFM 940/800/680 1180/1000/850 1500/1280/1080
Cooling Capacity (H/M/L) kW 8.22/7.39/6.54 10.39/9.25/8.2 12.9/11.51/10.21
Water flow rate L/h 1414 1787 2219
Water pressure drop kPa 31.2 44 40

Fan Coil Units


Fan Coil Units

Heating Capacity (H/M/L) kW 13.85/11.08/9 17.58/14.06/11.42 17.6/14.08/11.44


Water pressure drop kPa 14.8 34.7 36.7
Power input (H/M/L) W 155/131/106 190/127/109 190/136/109

R05 (Standard) RM12A (Option) KJR-12B (Option) KJR-29B (Option) Sound pressure level (H/M/L) dB(A) 48/44/39 49/45/40 50/46/41
Fan motor Type Low noise 3-speed fan motor
Quantity 1
Fan Type Centrifugal, forward-curved blades
High-lift Drain Pump 750mm
Coil
Quantity
Row 2
1
2 3
Max. working pressure MPa 1.6
Standard built-in drain pump with 750mm pump head for normal Diameter mm Φ7
Panel Net dimensions (W×H×D) mm 950×45×950
size and 500mm for compact size. Packing size (W×H×D) mm 1035×90×1035
Net weight kg 6
Gross weight kg 9
Body Net dimensions (W×H×D) mm 840×300×840
Packing size (W×H×D) mm 900×330×900

Fresh Air Intake Net weight


Gross weight
kg
kg
30.5
36.2
30.5
36.2
31.8
36
Pipe Water inlet/outlet pipe inch RC3/4
Fresh air can enter through the cassette unit so you can enjoy even connections Drain pipe mm ODΦ32

fresher air in a room. Notes:


1. H: High fan speed; M: Medium fan speed; L: Low fan speed.
2. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB.
Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.
3. Noise is tested in a semi-anechoic test room.

35 36
2-Row Duct
Duct Series
Various Selections MKT2-200G12 MKT2-300G12 MKT2-400G12 MKT2-500G12 MKT2-600G12
Model Non-AEH MKT2-200G30 MKT2-300G30 MKT2-400G30 MKT2-500G30 MKT2-600G30
Versions for 2 pipe systems. Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 340/255/170 510/385/255 680/510/340 850/640/425 1020/765/510
Versions for normal/large temperature difference systems. CFM 200/150/100 300/225/150 400/300/200 500/375/250 600/450/300
2, 3 or 4 rows coil for 2-pipe systems. Standard external static pressure Pa G12 models: 12; G30 models: 30
Cooling Capacity (H/M/L) kW 2/1.74/1.52 2.7/2.31/2.03 3.6/3.11/2.66 4.4/3.74/3.25 5.5/4.58/4.09
Large range of available static pressure. Water flow rate l/h 344 464 619 757 946
Water pressure drop kPa 5 11 19 22 14
Wired controller is optional. Heating Capacity (H/M/L) kW 3.2/2.75/2.37 4.3/3.74/3.23 5.4/4.64/4.05 6.8/5.78/5.07 8.1/6.77/5.92
Four fan speeds are avaliable: low, medium, high and one reserved for more choice. Water pressure drop kPa 4.2 9.5 15.5 18.3 11.8
Power input 12Pa (H/M/L) W 31/25/22 50/40/35 60/48/42 80/64/56 97/78/68
30Pa (H/M/L) W 45/36/32 60/48/42 67/54/47 89/71/62 110/88/77

High Efficiency Sound 12Pa (H/M/L) dB(A) 36/34/29 38/33/29 38/35/31 39/36/32 40/36/33
pressure level 30Pa (H/M/L) dB(A) 41/37/31 41/37/32 42/39/33 45/41/34 46/41/35
Fan motor Type Low noise 3-speed fan motor
Highly efficient heat exchange for complete contranatant flow. Quantity 1
Fan Type Centrifugal, forward-curved Blades
Quantity 1 2 2 2 2
Coil Row 2
Flexible Installation Max. working pressure
Diameter
MPa
mm
1.6
Φ9.52
Net dimensions (W×H×D) mm 741×241×522 841×241×522 941×241×522 941×241×522 1161×241×522
Left and right hand piping connections are optional, flexible installation. Packing size (W×H×D) mm 790×260×550 890×260×550 990×260×550 990×260×550 1210×260×550
Net weight kg 13.9 16.5 19.2 19.2 22
Gross weight kg 16.2 19 21.6 21.6 25
Water inlet/outlet pipe Inch RC3/4
Drain pipe mm ODΦ24

MKT2-800G12 MKT2-1000G12 MKT2-1200G12 MKT2-1400G12


Model Non-AEH MKT2-800G30 MKT2-1000G30 MKT2-1200G30 MKT2-1400G30
Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 1360/1020/680 1700/1275/850 2040/1530/1020 2380/1785/1190
CFM 800/600/400 1000/750/500 1200/900/600 1400/1050/700
Standard external static pressure Pa G12 models: 12; G30 models: 30
Cooling Capacity (H/M/L) kW 7.5/6.33/5.68 8.9/7.61/6.41 10.8/9.13/7.93 12.3/10.46/9.27
Water flow rate l/h 1290 1531 1858 2116
Water pressure drop kPa 14 22 39 46

Fan Coil Units


Fan Coil Units

Heating Capacity (H/M/L) kW 11/9.48/8.25 13.5/11.72/10.03 16.5/14.05/12.24 19.5/16.85/14.63


Standard Return Air Plenum and Filter Water pressure drop kPa 12.5 19 32.6 40.1
Power input 12Pa (H/M/L) W 140/112/98 172/138/120 205/164/144 216/173/151
30Pa (H/M/L) W 130/104/91 171/137/120 212/170/148 249/200/174
Standard return air plenum and filter guarantees clean air supply and stable air flow rate.
Sound 12Pa (H/M/L) dB(A) 42/37/33 44/39/34 46/40/35 48/42/37
pressure level 30Pa (H/M/L) dB(A) 46/41/36 47/43/37 48/44/38 49/44/39
Fan motor Type Low noise 3-speed fan motor
Quantity 2
Fan Type Centrifugal, forward-curved Blades
Fresh Air Intake Coil
Quantity
Row
4
2
Max. working pressure MPa 1.6
Fresh air can enter through the duct unit so you can enjoy even Diameter mm Φ9.52
Net dimensions (W×H×D) mm 1461×241×522 1566×241×522 1856×241×522 2022×241×522
fresher air in a room. Packing size (W×H×D) mm 1510×260×550 1615×260×550 1905×260×550 2070×260×550
Net weight kg 30.9 33.4 38.5 42.1
Gross weight kg 34.5 37 42 47.5
Water inlet/outlet pipe Inch RC3/4
Drain pipe mm ODΦ24

Notes:
1. H: High fan speed; M: Medium fan speed; L: Low fan speed.
2. The data are test under standard external static pressure.
3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB.
Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.
4. Noise is tested in a semi-anechoic test room.

37 38
3-Row Duct 4-Row Duct

Model MKT4-200G30 MKT4-300G30 MKT4-400G30 MKT4-500G30 MKT4-600G30 MKT4-800G30


MKT3-200G12 MKT3-300G12 MKT3-400G12 MKT3-500G12 MKT3-600G12
Model Non-AEH Power supply V/Ph/Hz 220-240/1/50
MKT3-200G30 MKT3-300G30 MKT3-400G30 MKT3-500G30 MKT3-600G30
Air flow (H/M/L) m3/h 340/255/170 510/385/255 680/510/340 850/640/425 1020/765/510 1360/1020/680
Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 340/255/170 510/385/255 680/510/340 850/640/425 1020/765/510 CFM 200/150/100 300/225/150 400/300/200 500/375/250 600/450/300 800/600/400
CFM 200/150/100 300/225/150 400/300/200 500/375/250 600/450/300 Standard external static pressure Pa 30
Standard external static pressure Pa G12 models: 12; G30 models: 30 Cooling Capacity (H/M/L) kW 2.5/2.16/1.87 3.3/2.85/2.47 4.4/3.72/3.22 4.8/4.18/3.64 6.2/5.38/4.65 8.8/7.43/6.57
Cooling Capacity (H/M/L) kW 2.2/1.9/1.68 3.1/2.7/2.3 4/3.4/2.95 4.6/3.96/3.45 5.8/4.88/4.45 Water flow rate l/h 430 568 757 826 1066 1514
Water flow rate l/h 378 533 688 791 998 Water pressure drop kPa 2.6 5 8.1 9.8 15.4 12.3
Water pressure drop kPa 14 26 18 24 36
Heating Capacity (H/M/L) kW 4.1/3.51/3.03 5.8/5.05/4.35 7.1/6.11/5.33 8.5/7.04/6.28 10.5/9.03/7.77 14.5/12.38/10.88
Heating Capacity (H/M/L) kW 3.5/3.08/2.59 5.3/4.61/3.98 6.8/5.85/5.1 7.9/6.95/6 9.8/8.6/7.4
Water pressure drop kPa 10.5 21.8 16.9 22.3 31.6 Water pressure drop kPa 2.2 4.2 6.9 8.1 12.7 10
Power input 12Pa (H/M/L) W 33/25/22 53/41/35 66/53/48 87/53/44 100/65/55 Power input (H/M/L) W 50/40/35 65/52/46 80/64/56 98/78/69 110/88/77 155/124/109
30Pa (H/M/L) W 49/37/33 64/49/42 75/61/54 93/56/47 114/74/63 Sound pressure level dB(A) 37/33/27 38/34/28 38/35/29 40/35/30 41/36/31 42/37/32
Fan motor Type Low noise 3-speed fan motor
Sound 12Pa (H/M/L) dB(A) 35/32/26 36/33/27 37/34/28 40/36/30 42/38/32
Quantity 1 1 1 1 1 2
pressure level 30Pa (H/M/L) dB(A) 41/37/31 42/38/32 43/39/33 44/40/34 45/41/35
Fan motor Type Low noise 3-speed fan motor Fan Type Centrifugal, forward-curved Blades
Quantity 1 Quantity 1 2 2 2 2 4
Fan Type Centrifugal, forward-curved Blades Coil Row 4
Quantity 1 2 2 2 2 Max. working pressure MPa 1.6
Coil Row 3
Diameter mm Φ9.52
Max. working pressure MPa 1.6
Net dimensions (W×H×D) mm 741×241×522 841×241×522 941×241×522 941×241×522 1161×241×522 1461×241×522
Diameter mm Φ9.52
Net dimensions (W×H×D) mm 741×241×522 841×241×522 941×241×522 941×241×522 1161×241×522 Packing size (W×H×D) mm 790×260×550 890×260×550 990×260×550 990×260×550 1210×260×550 1510×260×550
Packing size (W×H×D) mm 790×260×550 890×260×550 990×260×550 990×260×550 1210×260×550 Net weight kg 15.3 17.5 20.7 20.7 23.5 32.9
Net weight kg 14.6 17 20.2 20.2 23 Gross weight kg 17.6 20 23.1 23.1 26.5 36.5
Gross weight kg 16.9 19.5 22.6 22.6 26 Water inlet/outlet pipe Inch RC3/4
Water inlet/outlet pipe Inch RC3/4
Drain pipe mm ODΦ24
Drain pipe mm ODΦ24

Model MKT4-1000G30 MKT4-1200G30 MKT4-1400G30 MKT4-1500 MKT4-2000


MKT3-800G12 MKT3-1000G12 MKT3-1200G12 MKT3-1400G12
Model Non-AEH Power supply V/Ph/Hz 220-240/1/50
MKT3-800G30 MKT3-1000G30 MKT3-1200G30 MKT3-1400G30
Air flow (H/M/L) m3/h 1700/1275/850 2040/1530/1020 2380/1785/1190 2550/2100/1300 3400/2550/1700
Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 1360/1020/680 1700/1275/850 2040/1530/1020 2380/1785/1190 CFM 1000/750/500 1200/900/600 1400/1050/700 1500/1240/760 2000/1500/1000
CFM 800/600/400 1000/750/500 1200/900/600 1400/1050/700 Standard external static pressure Pa 30 30 30 30
Standard external static pressure Pa G12 models: 12; G30 models: 30 Cooling Capacity (H/M/L) kW 9.5/8.18/7.06 11.8/9.82/8.74 13/11.23/9.83 13.5/11.5/10.1 18/15.3/13.5
Cooling Capacity (H/M/L) kW 8.2/6.88/6.25 9/7.8/6.57 11/9.8/8.35 12.5/10.8/9.44 Water flow rate l/h 1634 2030 2236 2322 3096
Water flow rate l/h 1410 1548 1892 2150 Water pressure drop kPa 18 21.2 24.7 11.5 26.2
Water pressure drop kPa 39 32 39 45

Fan Coil Units


Fan Coil Units

Heating Capacity (H/M/L) kW 16.3/13.45/12.05 16.5/14.05/12.23 17/14.31/12.69 17.5/14.9/13.2 23.4/19.8/17.5


Heating Capacity (H/M/L) kW 13.6/11.97/10.2 16/14.24/12 20.1/18.27/15.43 21/18.7/15.75
Water pressure drop kPa 33.8 30.7 34.6 40.1 Water pressure drop kPa 15.4 17.6 20.8 10 24.3
Power input 12Pa (H/M/L) W 145/121/108 180/114/97 210/140/120 222/179/155 Power input (H/M/L) W 180/144/126 220/176/154 275/220/193 236/189/165 360/288/252
30Pa (H/M/L) W 154/129/114 180/114/97 220/147/126 278/224/194 Sound pressure level dB(A) 44/39/33 45/40/34 47/42/36 48/44/39 50/46/41
Auxiliary electric heater (AEH) W 2200 2200 3200 3200 Fan motor Type Low noise 3-speed fan motor
Sound 12Pa (H/M/L) dB(A) 43/39/33 45/41/35 46/42/36 48/44/38
Quantity 2 2 2 1 1
pressure level 30Pa (H/M/L) dB(A) 46/42/36 47/43/37 48/44/38 49/45/39
Fan motor Type Low noise 3-speed fan motor Fan Type Centrifugal, forward-curved Blades
Quantity 2 Quantity 4 4 4 2 3
Fan Type Centrifugal, forward-curved Blades Coil Row 4
Quantity 4 Max. working pressure MPa 1.6
Coil Row 3
Diameter mm Φ9.52
Max. working pressure MPa 1.6
Net dimensions (W×H×D) mm 1566×241×522 1856×241×522 2022×241×522 1369×342×612 1500×342×612
Diameter mm Φ9.52
Net dimensions (W×H×D) mm 1461×241×522 1566×241×522 1856×241×522 2022×241×522 Packing size (W×H×D) mm 1615×260×550 1905×260×550 2070×260×550 1421×381×619 1552×381×619
Packing size (W×H×D) mm 1510×260×550 1615×260×550 1905×260×550 2070×260×550 Net weight kg 35.4 40.5 44.1 46 57
Net weight kg 31.9 34.4 39.5 43.1 Gross weight kg 39.1 44 49.4 49.8 61
Gross weight kg 35.5 38.1 43 48.4 Water inlet/outlet pipe Inch RC3/4
Water inlet/outlet pipe Inch RC3/4
Drain pipe mm ODΦ24
Drain pipe mm ODΦ24

Notes: Notes:
1. H: High fan speed; M: Medium fan speed; L: Low fan speed. 1. H: High fan speed; M: Medium fan speed; L: Low fan speed.
2. The data are test under standard external static pressure. 2. The data are test under standard external static pressure.
3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB.
Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.
4. Noise is tested in a semi-anechoic test room. 4. Noise is tested in a semi-anechoic test room.

39 40
A4 Type Duct High Static Pressure Duct

Model Non-AEH MKT3H-800G70 MKT3H-1000G70 MKT3H-1200G70 MKT3H-1400G70


Model MKT3-800G50-A4 MKT4-800G50-A4 MKT3-1000G50-A4 MKT4-1000G50-A4
Power supply V/Ph/Hz 220-240/1/50 Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 1500/1412/1265 1400/1342/1200 1700/1664/1554 1650/1527/1405 Air flow (H/M/L) m3/h 1360/1220/1090 1700/1530/1380 2040/1880/1610 2380/2120/1860
CFM 882/831/745 824/790/706 1000/980/915 970/900/827 CFM 800/720/640 1000/900/810 1200/1105/950 1400/1250/1095
Standard external static pressure Pa 50 Standard external static pressure Pa 70
Cooling Capacity (H/M/L) kW 6.97/6.66/6.28 7.92/7.56/7.09 7.77/7.58/7.33 8.15/7.93/7.54 Cooling Capacity (H/M/L) kW 6.6/6.37/6.12 8.8/8.19/7.57 10/9.44/8.53 12/11.47/10.24
Water flow rate l/h 1198 1363 1336 1402 Water flow rate l/h 1135 1514 1720 2064

Water pressure drop kPa 19.0 13.5 24.5 21.4 Water pressure drop kPa 8 24 24 36
Heating Capacity (H/M/L) kW 9.7/8.54/7.18 13.2/11.48/9.9 15/12.9/11.25 17.9/15.75/13.6
Heating Capacity (H/M/L) kW 9.57/9.09/8.43 10.42/9.89/9.12 10.61/10.25/9.82 11.25/10.72/10.06
Water pressure drop kPa 8.4 25 23.4 34.2
Water pressure drop kPa 16.9 39.7 21.1 23.3
Power input (H/M/L) W 320/300/285 350/320/300 350/320/290 350/300/285
Power input (H/M/L) W 151/130/111 144/124/105 174/147/130 176/146/128
Sound pressure level dB(A) 49.7/47.8/45.6 48.4/47.9/46.6 50.1/48/45.8 49.5/48.1/47.3
Sound pressure level dB(A) 49/42/35 50/43/36 51/44/37 52/45/38
Fan motor Type Low noise 3-speed fan motor
Fan motor Type Low noise 3-speed fan motor
Quantity 1
Quantity 1
Fan Type Centrifugal, forward-curved Blades
Fan Type Centrifugal, forward-curved Blades
Quantity 2
Quantity 1
Coil Row 3 4 3 4
Coil Row 2 3 3 4
Max. working pressure MPa 1.6 Max. working pressure MPa 1.6
Diameter mm Φ9.52 Diameter mm Φ9.52
Net dimensions (W×H×D) mm 1180x340x612 Net dimensions (W×H×D) mm 946×400×816
Packing size (W×H×D) mm 1310x380x693 Packing size mm Left connection: 1075×480×857/1075×480×925 Right connection: 1015×480×857/1015×480×925
Net weight kg 38.3 39.3 39.8 40.8 Net weight kg 50/53 52/55 52/55 54/57
Gross weight kg 47.2 47 48.6 49.6 Gross weight kg 55/58 57/60 57/60 59/62
Water inlet/outlet pipe Inch RC3/4 Water inlet/outlet pipe Inch RC3/4
Drain pipe mm ODΦ24 Drain pipe mm ODΦ32

Model Non-AEH MKT3H-1600G100 MKT3H-1800G100 MKT3H-2200G100


Model MKT4-1200G50-A4 MKT4-1400G50-A4 MKT4-1600G50-A4 MKT4-1800G50-A4 MKT4-2000G50-A4
Power supply V/Ph/Hz 220-240/1/50 Power supply V/Ph/Hz 220-240/1/50
Air flow (H/M/L) m3/h 2040/1851/1666 2420/1851/1666 2430/1917/1742 3380/2239/1878 3670/2544/2199 Air flow (H/M/L) m3/h 2720/2450/2170 3060/2750/2450 3740/3360/2990
CFM 1200/1090/981 1424/1090/981 1431/1128/1025 1990/1318/1105 2160/1497/1294 CFM 1600/1440/1280 1800/1620/1440 2200/1980/1760
Standard external static pressure Pa 50 Standard external static pressure Pa 100
Cooling Capacity (H/M/L) kW 10.8/10.17/9.55 12.14/10.17/9.55 12.19/10.54/9.87 16.16/12.35/11.01 17.34/13.75/12.44 Cooling Capacity (H/M/L) kW 14.1/13.03/11.87 15.8/14.6/13.46 19.9/18.58/17.24
Water flow rate l/h 1890 2089 2096 2779 2983 Water flow rate l/h 2425 2718 3423

Fan Coil Units


Fan Coil Units

Water pressure drop kPa 27.8 32.5 33.4 58.3 61.5 Water pressure drop kPa 52 90 130
Heating Capacity (H/M/L) kW 21.2/18.23/15.69 23.8/20.94/17.85 30/26.7/22.5
Heating Capacity (H/M/L) kW 14.3/13.23/12.22 16.08/13.23/12.22 16.55/13.83/12.9 21.7/15.79/13.91 23.4/17.92/16.08
Water pressure drop kPa 51 85 121
Water pressure drop kPa 24.8 29.2 30.0 52.3 52.9
Power input (H/M/L) W 550/520/500 800/680/620 950/860/760
Power input (H/M/L) W 320/284/250 392/284/250 482/338/296 538/358/308 583/387/334
Sound pressure level dB(A) 50.9/50/48.5 51.7/50/49.5 52.9/50.7/50 53.6/51.1/50.2 54.4/52.7/51.6
Sound pressure level dB(A) 54/47/40 60/53/46 61/54/47
Fan motor Type Low noise 3-speed fan motor
Fan motor Type Low noise 3-speed fan motor
Quantity 1
Quantity 1
Fan Type Centrifugal, forward-curved Blades
Fan Type Centrifugal, forward-curved Blades
Quantity 2 2 2 3 3
Quantity 2
Coil Row 4
Coil Row 3
Max. working pressure MPa 1.6 Max. working pressure MPa 1.6
Diameter mm Φ9.52 Diameter mm Φ9.52
Net dimensions (W×H×D) mm 1369x340x612 1369x340x612 1369x340x612 1500x340x612 1500x340x612 Net dimensions (W×H×D) mm 1290×400×809
Packing size (W×H×D) mm 1490x380x693 1490x380x693 1490x380x693 1620x380x693 1620x380x693 Packing size (W×H×D) mm Left connection: 1448×460×877/1448×460×950 Right connection: 1383×422×877/1368×460×950
Net weight kg 46.3 46.3 46.3 54.8 54.8 Net weight kg 76
Gross weight kg 56.4 56.4 56.4 64.6 64.6 Gross weight kg 83
Water inlet/outlet pipe Inch RC3/4 Water inlet/outlet pipe Inch RC3/4
Drain pipe mm ODΦ24 Drain pipe mm ODΦ32
Notes: Notes:
1. H: High fan speed; M: Medium fan speed; L: Low fan speed. 1. H: High fan speed; M: Medium fan speed; L: Low fan speed.
2. The data are test under standard external static pressure. 2. The data are test under standard external static pressure.
3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB. 3. Cooling conditions: entering water 7°C, temperature rise 5°C, entering air temperature 27°C DB/19°C WB.
Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions. Heating conditions: entering water 50°C, entering air temperature 20°C DB, the same water flow as the cooling conditions.
4. Noise is tested in a semi-anechoic test room. 4. Noise is tested in a semi-anechoic test room.

41 42
Dimensions Duct
Dimensions (unit: mm)
F
4-way cassette A
B (Air return)
241
180

2-pipe 4-way cassette

241
180
Dimensions (unit: mm)

262
Terminal box

522
470
water inlet
Tubing side Drain side C water outlet
air release valve

170

258
Drain port
4-10×16 hanger slots

128
56
116 D 10
E 50 140
680(Hook-location)

2-pipe duct
950(Panel)
840(Body)

Size A B C D E F

A
200CFM 545 485 513 485 741 583

D
B

C
300CFM 645 585 613 585 841 683

400CFM 745 685 713 685 941 783

500CFM 745 685 713 685 941 783


780(Hook-location)
600CFM 965 905 933 905 1161 1003
840(Body)
950(Panel) 800CFM 1265 1205 1233 1205 1461 1303
Size
A B C D
Model 1000CFM 1370 1310 1338 1310 1566 1408
MKA-600R(A) 1200CFM 1660 1600 1628 1600 1856 1698
230 170 135 185
MKA-750R(A)
MKA-950R(A) 1400CFM 1826 1766 1794 1766 2022 1864
MKA-1200R(A) 300 190 145 195
MAK-1500R(A)

Air filter A J Model MKT3-800/1000G50-A4 MKT4-1200/1400/ MKT4-1800/


B Size MKT4-800/1000G50-A4 1500/1600G50-A4 2000G50-A4
Terminal box Drain port ZG3/4” A 960 1085 1277
Service Space (unit: mm) B 900 1135 1327
Water inlet RC3/4” C 910 1112 1308

H
Water outlet RC3/4” D 885 1085 1277
0 0 E 1180 1369 1500

I
Drain pipe joint C Air release valve

Fan Coil Units


Fan Coil Units

Water pipe joint F 150 160 160

G
4-10×16 hanger slots G 195 195 195

145
0 0 K

58
H 335 335 335
F D 40 19 L 10
E M I 612 612 612
>1000

J 342 342 342


>1000 K 231 231 231
L 230 230 230
>330

Notes:
M 340 340 340
This figure is for reference only, actual product may differ.
The dotted line in the figure is the dimension for air return plenum.
Units with air return plenum is standard, unis without air return plenum can be customized.
Ceiling
Ceiling
Outlet
Outlet Inlet Inlet Outlet Panel
>2500

880 (ceiling
(ceilinghole) High static pressure duct
>1000

600mm hole)
>1000 Model MKT3H-800G70
MKT3H-1600G100
MKT3H-1000G70
MKT3H-1800G100
Dimensions (unit:mm) Size MKT3H-1200G70
MKT3H-2200G100
MKT3H-1400G70
Ground
Ground A 946 1290
Drain port ZG5/4” B 816 809
2-pipe 4-way cassette K (Air return) C 400 400
Air release valve
D 778 1118
E 767 765
Water outlet RC3/4” F 306 900
water inlet RC3/4” G 219 249

B
E
H 88 88
Terminal box I 37 39
J 338 320
K 512 995
G F
C D H
A

43 44
Control Devices Accessories
Wireless Remote Controllers PC Board Control Kit for FCU
Available for all non-PCB FCUs.
Model Appearance Function Descriptions Applicable FCUs
Flexibility installation: can be attached to the unit, mounted on a wall or hung under a ceiling.
External installation making maintenance more convenient.
R05/BGE
LCD display screen 4-way Cassette (standard) Functions: three fan speeds control, Water pump control, Long-distance ON/OFF control, ALARM function,
Mode control electric heater control.
Fan speeds control
Operating status can be displayed by wired controller lamp indicator.
Time setting / Temp. setting / Swing setting Cassette series (optional)
RM12/E Centralized control function.
BMS control function through Modbus protocol.
Centralized control
Wired Controllers
Model Appearance Function Descriptions Applicable FCUs

LCD display screen


Mode control
KJRP-86A1-E Duct without electric heater (optional)
Fan speeds control
X,Y,E X,Y,E X,Y,E
Timer setting / Temp. setting

Mechanical thermostat X,Y,E


Mode control
KJR-18B/E Duct without electric heater (optional)
Fan speeds control
Temp. setting
Centralized controller
LCD display screen
Mode control / Fan speeds control BMS control function through Modbus protocol
KJR-21B/D Duct with electric heater (optional)
Electric heater control
Temp. setting
Receiving remote signal
Mode control
KJR-29B Cassette series (optional)
Fan speeds control
Adress. setting

Swing function P,Q,E P,Q,E


P,Q,E
Mode control

Fan Coil Units


Fan Coil Units

KJR-12B Cassette series (optional)


Fan speeds control P,Q,E RS232 Pin hole BMS
Temp. setting
Modbus
P
Q R+
R- Modbus
E E

USB port

Model CE-FCUKZ-03 CE-FCUKZ-04


Centralized Controllers Applicable appliance 2-pipe FCUs 4-pipe FCUs

Power supply V-Ph-Hz 220~240-1-50/60


Model Appearance Function Descriptions Applicable FCUs
Operation range Room temp. C
o
17-30
Large LCD display screen
Max. of 64 FCUs can be controlled by a CCM03 Inlet water temp. C
o
3-75
CCM03 FCUKZ-03 FCUKZ-04
Mode control / fan speed control Temp. controlling precision C
o
±1
Time setting / temp. setting / swing setting
Net dimension W×H×D mm 296×66×212
All FCUs
Weekly schedule function Packing size W×H×D mm 410×115×262
CCM09 (Compact 4-way cassette FCUs need adding NIM01 module,
Basic functions are same as CCM03 non-PCB FCUs need adding PC board control kit) Net weight kg 1.4

Gross weight kg 2.5

Touch-style keys
CCM30
Basic functions are same as CCM03

45 46
Network Module
Achieve centralized control through XYE connection;
Application of Central Control &
Software Control
XYE terminals
Only available for FCU Cassette Series;
Address setting should be same as connecting FCU; LED Side port
connect to
There LEDs display: operation indicator lamp, communication indicator lamp CN20 of
FCU PCB Up to 64 units
and malfunction indicator lamp.
Address setting
Centralized
MD-NIM01 controller
PCB Kit NIM01
Centralized wiring
Centralized controller

Up to 16 systems
XYE XYE XYE XYE XYE
Up to 64 units
Up to 64 FCUs

Centralized
CN20 on PCB CN20 on PCB CN20 on PCB CN20 on PCB CN20 on PCB controller

PCB Kit PCB Kit

Valve Kit
Working Voltage: AC230±10%, 50/60Hz (24V can be customized).
PC Access
Power Consumption: 4W M-interface
LAN

Fan Coil Units


Fan Coil Units

Nominal Pressure: 1.6MPa. Laptop Access

Applied Medium: Cold or hot water, 50% glycol water liquor. M-net

Medium Temperature: 2 - 15°C (DDSTF-01), -20 - 1°C (DDSTF-04/05). Pad Access

Environment Temperature: -5 - 50°C (DDSTF-01), 0 - 50°C (DDSTF-04/05). DDSTF-01


Cloud Servers 4th generation monitoring system

Model DN(mm) Inner Screw Thead Applicable Appliance Data converter


PC
CCM15
DDSTF-01 20 3/4” 2-pipe cassette/duct/floor standing, 4-pipe duct
Router
Internet
DDSTF-04 15 1/2” 4-pipe cassette (for hot water)
DDSTF-04 BMS BACnet
BMS gateway
Modubus
DDSTF-05 20 3/4” 2-pipe ceiling & floor, 4-pipe cassette (for cold water) DDSTF-05 LonWorks

PC in LAN
TCP/IP network

47 48
Selection Software Selection Interface

Features

Select by entering air and water conditions as well as fan speed.


Easy to operate interface and visual display. Report Data Interface
Powerful project management function.

Main Interface

Fan Coil Units


Fan Coil Units

49 50

You might also like