Control systems
Local PC
• column library Remote PC ÄKTAexplorer 10 XT
• scouting schemes
• method templates Room 2
Real-time overview of the system Fig. 1. UNICORN control system – a complete control,
and separation evaluation and reporting system.
New method templates are created easily and conventional Fig. 2. A Media screening (HiTrap™ HIC Test Kit, 1 ml
method programming can be used to fine tune the method. columns) during purification development of a recombinant
antigen binding fragment. B Scale up (200 ml column) of the
Complete manual programming control of systems is also an
optimized purification of the recombinant antigen binding
option.
fragment. Purification can now be transferred to a BioProcess
system.
User selected
scouting parameters
▲
Scouting schemes. User defined questions
Select technique
Select template
▲
▲
Fig. 5A. User defined Start Protocols to follow Standard
Select column Operating Procedures.
▲
▲ Run
User selected
monitor values
User selected
▲
real-time display
▲
Flow path and Fig. 8. Rapid identification of result files using QuickView.
valve positions
An optional UNICORN analysis module includes additional System control and data access via a PC network are easy to
quantification options, such as a unique molecular weight use, providing an overview of operations and security of
estimation for proteins separated by gel filtration and results. User levels from Administrator to Process Operator
calculations using internal/external standards for reference. can be defined and each user is password protected. All
functions are subject to user access set up by the user
Procedures and reports are easily customized to suit
company (Figure 10). Operators supervise and control any
individual needs. Reports can be generated in formats
system in the network in real time, from a remote or local
suitable for presentation (Figure 9). Curves and tables can
PC, switching smoothly between supervised systems during
be copied into other office programmes such as Word or
runs.
Powerpoint for presentation.
All run data are stored in a single, unalterable Result File,
Systems control, network overview and together with the method, start protocols and run log
complete data security (Figure 11). The system audit trail is stored separately. Data
includes records of manual interactions and all other events
UNICORN controls ÄKTAdesign and BioProcess systems occurring during the run. Results are saved automatically on
from Amersham Pharmacia Biotech, but may be adapted to the local computer or on the server in networked
control other liquid handling process units and to connect installations. Evaluation and generation of reports can be
to other control systems or Plant Management systems. made locally or at remote PCs. If network communication
UNICORN controls up to four systems from one PC, fails during a run, the run will continue and the result will be
simultaneously, independently or in a pre-programmed saved on the local PC.
sequence. UNICORN network support allows control and
monitoring of systems from any connected UNICORN
workstation, subject to access rights defined by the system
administrator. Figure 1 (front page) illustrates how Fig. 11. All run data in a single result file.
UNICORN control can be applied in a fully networked
system. UNICORN is specifically designed for a Windows
NT operating system. An “open connection interface” (Figure 12) gives the
possibility to communicate with any other Control and Data
Acquisition or Archiving system. For implementation of this
communication UNICORN includes a driver that has been
developed according to OPC specification 1.0A*. Amersham
Pharmacia Biotech can undertake customer ordered projects
to assist with the establishment of such communication
systems.
Open Connection
Interface Module
Define access level
Interface for Other systems
specific driver
System
Fig. 10. Defined user access levels for added security.
Reduces time and costs for preparation Documentation is available for review in a formal vendor
audit at Amersham Pharmacia Biotech. This includes
of submissions to authorities
requirement including requirement specification, system
specification, test protocol and report, source code listing
Complete documentation and protection and reviews of Standard Operating Procedures for the
software development model.
Logbook
Logbook Installation Qualification and Operational Qualification
(IQ/OQ) services are available. For further information
please contact your local representative.
Method Method System Result
editor Evaluation
control
Control System Description
UNICORN control systems is based on a dedicated
controller and I/O interface with a computer based graphical
user interface. This graphical user interface is an integral part
Controlled user access Report of the control system.
functionality
• Determination of molecular weight by gel filtration
chromatography system
System strategies include all information needed by the Main Menu Method Editor System Control Evaluation
UNICORN PC
Control Control Control Control
unit unit unit unit
Electrical CAN/
cabinet Optomux Optomux
I/O P-line
module monitor
Network requirements
Supported network cards:
3COM Etherlink III
Compaq™ Netelligent 10/100 TX Embedded UTP Controller
Compaq Integrated NetFlex-3 Controller
AMD PCNET PCI Ethernet Adapter (Integrated)
Novell™ NetWare™ version 4.50.819 or later, alternatively
Windows NT Server 4.0
A valid network connection
* Available specification for industrially hardened screens.
to order:
Asia Pacific Tel: +852 2811 8693 Fax: +852 2811 5251 Australasia Tel: +61 2 9894 5152 Fax: +61 2 9899 7511 Austria Tel: 01 576 0616 20 Fax: 01 576 0616 27 Belgium Tel: 0800 73 888 Fax: 03 272 1637
Canada Tel: 1 800 463 5800 Fax: 1 800 567 1008 Central, East, South East Europe Tel: +43 1 982 3826 Fax: +43 1 985 8327 Denmark Tel: 45 16 2400 Fax: 45 16 2424 Finland Tel: 09 512 3940 Fax: 09 512 1710
France Tel: 0169 35 67 00 Fax: 0169 41 9677 Germany Tel: 0761 4903 401 Fax: 0761 4903 405 Italy Tel: 02 27322 1 Fax: 02 27302 212 Japan Tel: 81 3 5331 9336 Fax: 81 3 5331 9370 Latin America
Tel: +55 11 3667 5700 Fax: +55 11 3667 87 99 Middle East and Africa Tel: +30 (1) 96 00 687 Fax: +30 (1) 96 00 693 Netherlands Tel: 0165 580 410 Fax: 0165 580 401 Norway Tel: 2318 5800 Fax: 2318 6800
Portugal Tel: 01 417 7035 Fax: 01 417 3184 Russian Federation Tel: +7 (095) 232 0250,956 1137 Fax: +7 (095) 230 6377 South East Asia Tel: 60 3 724 2080 Fax: 60 3 724 2090 Spain Tel: 93 594 49 50
Fax: 93 594 49 55 Sweden Tel: 018 612 19 00 Fax: 018 612 19 10 Switzerland Tel: 01 802 81 50 Fax: 01 802 81 51 UK Tel: 0800 616 928 Fax: 0800 616 927 USA Tel: +1 800 526 3593 Fax: +1 800 329 3593
UNICORN, BioProcess, HiTrap, FPLC and ÄKTA are trademarks of Amersham Pharmacia Biotech Limited or its subsidiaries. Amersham is a trademark of Nycomed Amersham plc. Pharmacia and Drop Design
Produced by Wikströms, Sweden 991726, Nov., 1999
are trademarks of Pharmacia & Upjohn. Compaq is a trademark of Compaq Computer Corporation. Novell and Netware are trademarks of Novell Inc. OPC is a trademark of the OPC Foundation. Windows NT is
a trademark of Microsoft Corporation. Amersham Pharmacia Biotech AB Björkgatan 30, SE-751 84 Uppsala, Sweden. Amersham Pharmacia Biotech UK Limited Amersham Place, Little Chalfont, Buckinghamshire
HP7 9NA, England. Amersham Pharmacia Biotech Inc 800 Centennial Avenue, PO Box 1327, Piscataway, NJ 08855 USA. Amersham Pharmacia Biotech Europe GmbH Munzinger Strasse 9, D-79111 Freiburg,
Germany. All goods and services are sold subject to the terms and conditions of sale of the company within the Amersham Pharmacia Biotech group that supplies them. A copy of these terms and conditions
is available on request. © Amersham Pharmacia Biotech AB 1999 – All rights reserved.
Printed matter. Licence 341 051