You are on page 1of 119

Fiber Sensor Guide Book

2014.06 panasonic.net/id/pidsx/global
GENERAL TERMS AND CONDITIONS
Please read this document carefully with respect to our product warranty policy before using our Panasonic Industrial Devices
SUNX products (“Products”). If you have any questions or comments regarding do’s and don’ts of the Products, please consult
your local Panasonic Industrial Devices SUNX authorized dealer for the correct use and application of the Products.

1. PRODUCT MODIFICATION & DISCONTINUANCE:


Panasonic Industrial Devices SUNX expressly reserves the right to modify, including the right to discontinue, any of the
Products, prior to their order, from time to time without notice.
2. WARRANTIES:
(1) Subject to the exclusions stated in 3 (EXCLUSIONS) herein below, Panasonic Industrial Devices SUNX warrants the
Products to be free of defects in material and workmanship for a period of one (1) year from the date of shipment under
normal usage in environments commonly found in manufacturing industry.
(2) Any Products found to be defective must be shipped to Panasonic Industrial Devices SUNX with all shipping costs paid
by Purchaser or offered to Panasonic Industrial Devices SUNX for inspection and examination. Upon examination by
Panasonic Industrial Devices SUNX, Panasonic Industrial Devices SUNX will, at its sole discretion, repair or replace at
no charge, or refund the purchase price of, any Products found to be defective.
3. EXCLUSIONS
(1) This warranty does not apply to defects resulting from any cause:
(i) which was due to abuse, misuse, mishandling, improper installation, improper interfacing, or improper repair by Purchaser;
(ii) which was due to unauthorized modification by Purchaser, in part or in whole, whether in structure, performance or specification;
(iii) which was not discoverable by a person with the state-of-the-art scientific and technical knowledge at the time of manufacture;
(iv) which was due to an operation or use by Purchaser outside of the limits of operation or environment specified by
Panasonic Industrial Devices SUNX;
(v) which was due to Force Majeure; and
(vi) which was due to any use or application expressly discouraged by Panasonic Industrial Devices SUNX in 5 (CAUTIONS
FOR SAFE USE) hereunder.
(2) This warranty extends only to the first purchaser for application, and is not transferable to any person or entity which
purchased from such purchaser for application.
(3) The performance data presented in this catalogue is only for guidance and shall not constitute any performance warranty
by Panasonic Industrial Devices SUNX.
4. DISCLAIMERS
(1) Panasonic Industrial Devices SUNX’s sole obligation and liability under this warranty is limited to the repair or
replacement, or refund of the purchase price, of a defective Product, at Panasonic Industrial Devices SUNX’s option.
(2) THE REPAIR, REPLACEMENT, OR REFUND IS THE EXCLUSIVE REMEDY OF THE PURCHASER, AND ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE HEREBY EXPRESSLY DISCLAIMED. IN NO EVENT SHALL PANASONIC INDUSTRIAL DEVICES
SUNX AND ITS AFFILIATED ENTITIES BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE
PRODUCTS, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR
ANY DAMANGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS
OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS.
5. CAUTIONS FOR SAFE USE
(1) The applications shown in this catalogue are only suggestions, and it is Purchaser’s sole responsibility to ascertain the
fitness and suitability of the Products for any particular application, as well as to abide by Purchaser’s applicable local
laws and regulations, if any.
(2) Never use the Products NOT rated or designated as “SAFETY SENSOR” in any application involving risk to life or
property. When such a use is made by Purchaser, such Purchaser shall indemnify and hold harmless
Panasonic Industrial Devices SUNX from any liability or damage whatsoever arising out of or in relation to such use.
(3) In incorporating the Products to any equipment, facilities or systems, it is highly recommended to employ fail-safe
designs, including but not limited to a redundant design, flame propagation prevention design, and malfunction
prevention design so as not to cause any risk of bodily injury, fire accident, or social damage due to any failure of such
equipment, facilities or systems.
(4) The Products are each intended for use only in environments commonly found in manufacturing industry, and, unless
expressly allowed in this catalogue, specification or otherwise, shall not be used in, or incorporated into, any equipment,
facilities or systems, such as those:
(a) which are used for the protection of human life or body parts;
(b) which are used outdoors or in environments subject to any likelihood of chemical contamination or electromagnetic
influence;
(c) which are likely to be used beyond the limits of operations or environments specified by
Panasonic Industrial Devices SUNX in this catalogue or otherwise;
(d) which may cause risk to life or property, such as nuclear energy control equipment, transportation equipment
(whether on rail or land, or in air or at sea), and medical equipment;
(e) which are operated continuously each day for 24 hours; and
(f) which otherwise require a high level of safety performance similar to that required in those equipment, facilities or
systems as listed in (a) through (e) above.
6. EXPORT CONTROL LAWS
In some jurisdictions, the Products may be subject to local export laws and regulations. If any diversion or re-export is to be
made, Purchaser is advised to abide by such local export laws and regulations, if any, at its own responsibility.
7. PURCHASER’S TRASFER OBLIGATIONS
If Purchaser resell or deliver the Products to a third party, Purchaser must provide such third party with a copy of this
document, all specifications, manuals, catalogs, leaflets and written information of any kind provided to Purchaser by
Panasonic Industrial Devices SUNX or its authorized local representative from time to time regarding the Products.
INDEX

Fiber Selection Guide Choose by model 2


Choose by shape/application 3
How to read Model No. 4
Earlier model comparison table 6
New Product Introduction Tough Fiber 8
Fibers Super Quality 10
Threaded Type 12
Square Head Type 14
Cylindrical Type 16
Sleeve 18
Flat Type 20
Small Spot 22
Narrow Beam 24
Wide Beam 25
Convergent Reflective Type 26
Retroreflective Type 27
Chemical / Oil-resistant 28
Heat-resistant 30
Vacuum-resistant 32
Liquid Leak / Liquid Detection 34
Fiber Options 42
Semi-custom Fibers 46
Fiber Dimensions Thru-beam Type 48
Retroreflective Type 55
Reflective Type 56
Others 66
Amplifiers FX-500 series Ver.2 70
FX-100 series 98
INDEX 112
2

New product Fiber Selection Guide


introduction
Tough
Fiber Choose by model
Thru-beam type Retroreflective type
Fiber
Selection Page Page Page
Guide

Model
Model No. Sensing range Model No. Sensing range Model No. Sensing range
Dimensions Dimensions Dimensions
Choose Specifications Specifications Specifications
by shape/
application FT-140 P.12 FT-Z30 FR-KZ22E
How to read P.53
Model No FT-30 P.11 FT-Z30E FR-KZ50E
P.24/P.27 P.55
Earlier models FT-31 P.12 FT-Z30EW FR-KZ50H
comparison
table FT-31S P.19 FT-Z30H FR-Z50HW
P.20
FT-31W P.12 FT-Z30HW
P.48
FT-40 P.11 FT-Z30W P.54
Fibers FT-42 P.12 FT-Z40HBW
Super FT-42S P.19 FT-Z40W
Quality
FT-42W FT-Z802Y P.29
Threaded
Type FT-43 P.12
Square Head FT-45X
Type
FT-A11
Cylindrical
Type FT-A11W
FT-A32 P.25 Reflective type
Sleeve
FT-A32W
Flat P.49 Page Page
Type FT-AL05
FT-E13
Model No. Sensing range Model No. Sensing range
Small
P.16/P.19 Dimensions Dimensions
Spot
FT-E23 Specifications Specifications
Narrow
Beam FT-F93 P.35 FD-30 P.11 FD-H30-KZ1V-S P.32
Wide FT-H13-FM2 FD-31 FD-H30-L32 P.31
Beam P.13
FT-H20-J20-S FD-31W FD-H30-L32V-S P.32
Convergent
Reflective FT-H20-J30-S FD-32G FD-H35-20S P.61
Type P.13/P.23
Retroreflective FT-H20-J50-S FD-32GX FD-H35-M2 P.31
Type P.30 P.56
FT-H20-M1 FD-40 P.11 FD-H35-M2S6
Chemical / Oil-
resistant FT-H20-VJ50-S FD-41 P.13 FD-HF40Y P.35
Heat- FT-H20-VJ80-S P.50 FD-41S FD-L10
resistant P.19
FT-H20W-M1 FD-41SW FD-L11
Vacuum-
resistant FT-H30-M1V-S P.32 FD-41W P.13 FD-L12W
Liquid Leak / FT-H35-M2 FD-42G FD-L20H
Liquid Detection P.30 P.13/P.23
FT-H35-M2S6 FD-42GW FD-L21
P.62
FT-HL80Y P.29 FD-60 P.11 FD-L21W P.26
FT-KS40 FD-61 FD-L22A
Fiber P.13 P.57
Options FT-KV26 FD-61G FD-L23
P.24
FT-KV40 FD-61S P.19 FD-L30A
FT-KV40W FD-61W FD-L31A
Semi-custom FT-L80Y P.29 FD-62 P.13 FD-L32H
fibers P.51
FT-R31 P.15 FD-64X FD-R31G
FT-R40 P.12 FD-A16 FD-R32EG
P.25 P.15/P.23
FT-R41W FD-AL11 FD-R33EG
Fiber P.58
Dimensions FT-R42W P.15 FD-E13 FD-R34EG P.63
P.17/P.19
Thru-beam FT-R43 FD-E23 FD-R41 P.15
Type
FT-R44Y FD-EG30 P.13/P.23 FD-R60 P.13
Retroreflective P.15/P.29
Type FT-R60Y FD-EG30S P.19 FD-R61Y P.15/P.29
Reflective FT-S11 P.16 FD-EG31 P.13/P.23 FD-S21 P.17
Type
FT-S20 P.11 FD-F4 FD-S30 P.11
Others FT-S21 FD-F41 FD-S31
P.16 P.52 P.59
FT-S21W FD-F41Y FD-S32
P.35 P.17
FT-S30 P.11 FD-F71 FD-S32W
P.64
FT-S31W FD-F8Y FD-S33GW
Amplifiers P.16
FT-S32 FD-FA93 FD-S60Y P.29
FX-500
series FT-V23 FD-H13-FM2 FD-V30
FX-100 FT-V24W FD-H18-L31 FD-V30W P.19
series P.19
FT-V25 FD-H20-21 FD-V50
P.31 P.60
FT-V30 FD-H20-M1 FD-Z20HBW
FT-V40 P.16 P.53 FD-H25-L43 FD-Z20W
P.21 P.65
INDEX FT-V80Y P.29 FD-H25-L45 FD-Z40HBW
FT-Z20HBW FD-Z40W
P.20
FT-Z20W FD-Z50HW P.24
3

Fiber Selection Guide New product


introduction

 Choose by shape Tough


Fiber

Threaded Type Square Head Type Cylindrical Type Sleeve Flat Type
S
‌ tandard type which I‌nstalled cleanly on H
‌ as a slender shape S
‌ uitable for sensing ‌ hin and rectangular
T Fiber
Selection
is mounted using the side of a that is mounted in narrow locations shape. Installed directly Guide
nuts. conveyor belt. using set screws. and sensing minute in narrow locations Model
objects. with screws. Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table

Fibers

P.12 P.14 P.16 P.18 P.20 Super


Quality
Threaded
Type

 Choose by beam shape


Square Head
Type
Cylindrical
Convergent
Small Spot Narrow Beam Wide Beam Reflective Type Retroreflective Type Type

Sleeve
S
‌ enses minute N
‌ ot easily affected S
‌ enses in the beam S
‌ enses in the limited I‌ deal for sensing
objects using a spot by surrounding band without missing range only. transparent objects Flat
Type
lens. obstacles. a work.
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
P.22 P.24 P.25 P.26 P.27 Heat-
resistant
Vacuum-
resistant
 Choose by quality  Choose by environment / performance Liquid Leak /
Liquid Detection
Liquid Leak /
Super Quality Chemical / Oil-resistant Heat-resistant Vacuum-resistant Liquid Detection
‌The variance of V
‌ arious kinds of liquids W
‌ ithstands at -60 °C U
‌ sable in high- C
‌ orresponds to
Fiber
beam intensity and can be detected due to -76 °F to 350 °C 662 °F temperatures of various liquid Options
beam axis is the fluorine contained 300 °C 572 °F and events.
extremely small. resin case vacuum
Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
P.10 P.28 P.30 P.32 P.34 Type
Reflective
Type

 Fiber sensor amplifiers guidance Others

Digital fiber sensor Digital fiber sensor


FX-500 series Ver. 2 FX-100 series Amplifiers
A
‌ t the industry's S
‌ uper functionality, FX-500
series
leading edge yet, economical price
FX-100
series

INDEX

P.70 P.98
4

New product Fiber Selection Guide


introduction
Tough
Fiber  How to read Model No.
Applies to the fiber in (P.10~P.35)

F -
Fiber
Selection
Guide
*1 *1
Model
Choose
by shape/
application *1: Excluding liquid leak / liquid detection fiber
How to read Series Name Type Shape, etc. Functions / Features
Model No
Earlier models
comparison
table

Symbol Details Symbol Details Symbol Details


Fibers T Thru-beam type None General-purpose None General-purpose
Super D Reflective type G Coaxial reflective W Sharp bending
Quality R Retroreflective type S Sleeve X Stainless-jacketed
Threaded
Type H Top sensing * Y Chemical-resistant
Square Head E Side sensing *
Type HB Top sensing + Bent *
Cylindrical
Type A Alignment
* is for Flat type (Z and KZ)
Sleeve
only
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam Lead
Symbol Details Details
Convergent No.
Reflective
Type 3 M3
Retroreflective 4 M4
Type None Treaded type
Chemical / Oil-
6 M6
resistant 14 M14
Heat- 4 M4
resistant R Elbow or square head
Vacuum-
6 M6
resistant 1 ø1 mm
Liquid Leak / S Cylindrical type 2 ø1.5 mm
Liquid Detection
3 ø2.5 or ø3 mm
KS Narrow beam 4 ø3.7 mm
Fiber
2 ø2 mm
Options 3 ø2.5 or ø3 mm
V Side-view
4 ø4 mm
5 ø5 mm
Semi-custom 4 ø4 mm
fibers KV Narrow beam / Side-view
2 1.5 × 2 mm
1 Fiber ø0.125 mm
E Ultra small diameter
Fiber
2 Fiber ø0.25 mm
Dimensions EG Coaxial 3 M3
Thru-beam 2 Thickness 2 mm
Type
3 Thickness 3 mm
Retroreflective Z Flat type
Type 4 Thickness 3.5 mm
Reflective 5 Thickness 5.2 mm
Type
2 Thickness 2.2 mm
Others KZ Narrow beam
5 Thickness 5.2 mm
3 Sensing width 32 mm
A Wide beam
1 Sensing width 10 to 19 mm
Amplifiers 1 Sensing width 11.1 mm
AL Array
FX-500
0 Sensing width 5.5 mm
series 1 Sensing range 0 to 10 mm (STD)
FX-100 L Convergent reflective type 2 Sensing range 11 to 30 mm (STD)
series
3 Sensing range 31mm or more (STD)
9 Mountable on pipe
F Liquid leak / Liquid detection
7 Liquid leak
INDEX
5
6

New product Fiber Selection Guide


introduction
Tough
Fiber Earlier Models Comparison Table(The
of old one. Please confirm the specification before use. )
specification of new fiber may be changed from that

Thru-beam type
Fiber
Selection
Page Page
Guide Old fiber New fiber Old fiber New fiber
Sensing range Sensing range
Model Model No. Model No. Dimensions Model No. Model No. Dimensions
Specifications Specifications
Choose
by shape/
application FT-A30 FT-A32 FT-KV40
How to read FT-WKV8 P.24
Model No FT-A8 FT-A11 FT-KV40W
Earlier models
P.25 P.49 P.51
comparison FT-AFM2 FT-WR80 FT-R41W
table FT-AL05 P.15
FT-AFM2E FT-WR80L FT-R42W
FT-B8 FT-43 P.12 P.48 FT-WS3 FT-S31W
Fibers FT-E12 FT-E13 FT-S21
P.16/P.19 FT-WS4
Super FT-E22 FT-E23 P.49 FT-S21W P.16 P.52
Quality
Threaded FT-F902 FT-F93 P.35 FT-WS8 FT-S31W
Type
Square Head
FT-FM10L FT-140 FT-WS8L FT-S32
Type P.12
FT-FM2 FT-42 FT-V25
Cylindrical P.48 FT-WV42 P.19
Type FT-FM2S FT-V24W
FT-42S P.19 P.53
Sleeve FT-FM2S4 FT-WZ4 FT-Z20W
Flat FT-K8 FT-KS40 FT-WZ4HB FT-Z20HBW
Type
Small FT-KV1 FT-KV26 P.24 P.51 FT-WZ7 FT-Z40W
Spot P.54
Narrow
FT-KV8 FT-KV40 FT-WZ7HB FT-Z40HBW
Beam
FT-NFM2 FT-31 P.12 FT-Z30 P.53
Wide FT-WZ8
Beam FT-NFM2S P.48 FT-Z30W P.54
Convergent FT-31S P.19
Reflective
Type
FT-NFM2S4 FT-Z30E P.20 P.53
FT-WZ8E
Retroreflective FT-P2 FT-S21 P.16 P.52 FT-Z30EW
Type
Chemical / Oil- FT-P40 FT-31 FT-Z30H P.54
resistant FT-WZ8H
Heat-
FT-P60 P.48 FT-Z30HW
resistant FT-42 P.12
FT-P80 FT-Z8 FT-Z30
Vacuum- P.53
resistant FT-P81X FT-45X P.49 FT-Z8E FT-Z30E
Liquid Leak /
Liquid Detection FT-PS1 FT-S11 P.16 P.52 FT-Z8H FT-Z30H P.54
FT-R80 FT-R40 P.12 P.51 ― FT-30
P.48
FT-SFM2 ― FT-40
Fiber FT-S32 P.16 P.52 P.11
Options FT-SFM2L ― FT-S20
P.52
FT-SFM2SV2 FT-V30 P.19 P.53 ― FT-S30

Semi-custom FT-SNFM2 FT-S21 P.16 P.52 ― FT-R31


fibers P.15 P.51
FT-T80 FT-42 P.12 P.48 ― FT-R43
FT-V10 FT-V40 P.16 P.53
Fiber FT-V22 FT-V23 P.52
Dimensions P.19
Thru-beam
FT-V41 FT-V25 P.53
Type
FT-31 Retroreflective type
Retroreflective FT-W4
Type FT-31W Page
Reflective P.12 P.48 Old fiber New fiber
Type FT-42 Sensing range
FT-W8 Model No. Model No. Dimensions
Others FT-42W Specifications
FT-A32 FR-KV1 FR-KZ22E
FT-WA30
FT-A32W FR-KZ21 FR-KZ50H
P.25 P.49 P.24/P.27 P.55
Amplifiers FT-A11 FR-KZ21E FR-KZ50E
FT-WA8
FX-500 FT-A11W FR-WKZ11 FR-Z50HW
series
FX-100
series

INDEX
7

Fiber Selection Guide New product


introduction
Reflective type Tough
Fiber
Page Page
Old fiber New fiber Old fiber New fiber
Model No. Model No. Sensing range Model No. Model No. Sensing range
Dimensions Dimensions Fiber
Specifications Specifications Selection
Guide
FD-A15 FD-A16 FD-SFM2SV2 FD-V50 P.19 P.65 Model

FD-AFM2 P.25 P.58 FD-SNFM2 FD-S31 P.17 P.64 Choose


by shape/
FD-AL11 application
FD-AFM2E FD-T40 FD-31 P.56 How to read
Model No.
FD-B8 FD-62 P.13 P.57 FD-61 P.13 P.57 Earlier models
FD-T80 comparison
FD-E12 FD-E13 FD-41 P.56 table
P.17/P.19
FD-E22 FD-E23 P.58 FD-V41 FD-V30 P.64
FD-EG1 FD-EG30 FD-41S P.19
FD-W44 P.56 Fibers
FD-EG2 P.13/P.23 FD-41SW
FD-EG31 Super
FD-EG3 FD-61 Quality
FD-W8 P.13 Threaded
FD-EN500S1 FD-61W Type
FD-EG30S P.19 P.59 P.57
FD-ENM1S1 FD-42G Square Head
Type
FD-WG4 P.13/P.23
FD-F705 FD-F71 FD-42GW Cylindrical
P.35 Type
FD-FA90 FD-FA93 FD-WKZ1 FD-Z50HW P.24 P.65
Sleeve
FD-61 FD-L21
FD-FM2 P.13 FD-WL41 Flat
FD-61G FD-L21W P.26 P.62 Type
Small
FD-FM2S P.57 FD-WL48 FD-L12W Spot
FD-61S P.19
FD-FM2S4 FD-S32 Narrow
Beam
FD-WS8
FD-G4 FD-42G FD-S32W P.17 P.64 Wide
Beam
FD-G6 FD-32G P.13/P.23 FD-WSG4 FD-S33GW Convergent
P.56 Reflective
Type
FD-G6X FD-32GX FD-31
FD-WT4 Retroreflective
FD-L4 FD-L20H FD-31W Type
P.13 P.56 Chemical / Oil-
FD-L41 FD-L21 FD-41 resistant
FD-WT8
FD-L43 FD-L22A FD-41W Heat-
resistant
FD-L44 FD-L11 P.62 FD-V30 Vacuum-
FD-WV42 P.19 P.64 resistant
FD-L44S FD-L10 P.26 FD-V30W Liquid Leak /
Liquid Detection
FD-L45 FD-L30A FD-WZ4 FD-Z20W
FD-L45A FD-L31A FD-WZ4HB FD-Z20HBW
P.21 P.65
FD-L46 FD-L32H P.63 FD-WZ7 FD-Z40W Fiber
Options
FD-L47 FD-L23 P.62 FD-WZ7HB FD-Z40HBW
FD-NFM2 FD-41 P.13 ― FD-30
P.56 Semi-custom
FD-NFM2S P.56 ― FD-40 fibers
FD-41S P.19 P.11
FD-NFM2S4 ― FD-60 P.57
FD-P2 FD-S21 P.17 P.63 ― FD-S30 P.64
Fiber
FD-P40 FD-31 P.13 P.56 ― FD-R31G Dimensions
FD-P50 FD-S32 P.17 P.64 Thru-beam
― FD-R32EG Type
P.15/P.23
FD-P60 FD-41 P.56 ― FD-R33EG P.63 Retroreflective
Type
FD-P80 FD-61 P.57 ― FD-R34EG Reflective
P.13 Type
FD-P81X FD-64X P.58 ― FD-R41 P.15
Others
FD-R80 FD-R60 P.63
FD-S80 FD-S32 P.17 P.64

Amplifiers
FX-500
series
FX-100
series

INDEX
8

Tough Fiber
New product
introduction
Tough
Fiber

Fiber
Unbreakable ! More flexible ! ECO !
Selection
Guide

Model
Conventional 3 types rolled into 1 !!
Choose
by shape/
application
How to read
Model No
Earlier models
comparison
table
Flexible fiber
Flexible durability

1
Fibers
Super
million
Quality times
Threaded
Type
Square Head
Type
Tough Fiber
Cylindrical
Type

Sleeve Sharp bending fiber Unbreakable


Flat
Type
Bending radius
Flexible durability 10 million times (Typical)

~R1
Small
Spot
Narrow
Beam
R2 mm
Bending conditions Bending radius: R10 mm
Reciprocating bending: 180°

Wide
Beam More flexible
Bending radius R2 mm
Convergent ~R4
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
General purpose fiber
Heat- Bending radius
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection
R25mm Stainless
e fi b
steel fittin
e r
gs are us
head of a
ll m o d e
ed
ls.
for th s to RoHS
nform tery
Clearly co d for secondary bat
an b e u se st re n g th
C
Fiber mounting
Improved
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
New tough fibers exceed normal optic fibers!
Type
Tough fibers can be used on moving parts, can be bent with precision, and offer high quality for all purposes.
Retroreflective
Type They go beyond what was commonly thought to be possible.
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
9

Unbreakable ECO New product


introduction
Tough
Fiber

Bending conditions Stainless steel fittings


Bending radius: R10 mm R0.394 in, are used for the fiber head Fiber
Selection
Guide
Reciprocating bending: 180° of all models. Model
● Clearly conforms Choose
by shape/
Flexible durability SUS to RoHS application
How to read
Model No.
● Can be used for
10 million times (Typical)
secondary batteries
● Improved
Earlier models
comparison
table

tightening torque
Fibers

More flexible R2 to R4 mm R0.079 to R0.157 in


Super
Quality
Threaded
Type
Example: FT-31 Example: FT-42 Square Head
Type
Cylindrical
Type
R

R2
Sleeve
M3
mm
R0.079 in
M4
R4 mm
R0.157 in
R Flat
Type
Small
Spot
Narrow
Ø1 mm Ø2.2 mm Beam
Ø0.039 in Ø0.087 in Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
Reduced the time in selecting fiber and in registrating part numbers resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

For Designers High-q For Buyers Low P


uality rice Fiber
Options

● High-qualityin whichever ● Cost savings!


tough fiber you choose! ● Reduced registration of part Semi-custom
fibers

● Easy selection! numbers!


● Reduced maintenance time Fiber
● Reducesrisk of breaking and Dimensions
in keeping stocks and Thru-beam
bending during installation! Type
replacement! Retroreflective
Type
Reflective

Reduced variation in detection


Type

Others

Beams at the fiber aperture are uniform, leading to stable sensing.

Previous Previous sharp Generally flexible fibers and Amplifiers


New fiber The new standard fiber is
flexible fiber bending fiber sharp bending fibers are composed of a single fiber FX-500
composed of multiple fiber series
core, achieving uniform light
cores, often resulting in large intensity. FX-100
series
variations in light intensity. ●Uniform and highly accurate sensing
●Stable sensing even if the fiber is bent

INDEX
10

Super Quality
New product
introduction
Tough
Fiber

It is a fiber with superior light intensity stability and


Fiber
Selection simple digital management when combined with the
Guide
FX-500 series amplifier. FT-40
Model
It offers stable sensing with an extremely small beam
Choose
by shape/
application
axis curvature and gap.
How to read
Model No
Earlier models
comparison Digital management is simple due to small differences in body.
table
When connected with the FX-500 series amplifiers, it has up to
4 times improved stability of incident light intensity compared
Super quality fiber FX-500 series
with traditional fibers. Management is simple even when “Stabilized incident light intensities”
Fibers
replacing amplifiers because the digital display shows the even in multiple units
Super approximate value.
Quality
Threaded Emitter intensity is also stable due to few curvatures and gaps
Type
in the beam axis.
Square Head
Type
Cylindrical
Type

Sleeve

Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective Stable emission amount within ±10 % ø2.2 mm ø0.087 in standard fiber
Type
Chemical / Oil- Variation in emission amount of the fiber core is
New material

resistant
Previous

Heat-
controlled down to less than ±10 %, achieving a
resistant stable detection.
Vacuum-
resistant
● Beam axis deviation: Thru-beam type within ±2°,
Liquid Leak /
Reflective type within ±3° Single core standard fiber In general, high-flexibility
Liquid Detection ● Beam axis centering precision: within ±150 µm with high flexibility types adopt a multi-fiber core,
Expanded temperature range which may result in large
variation in light emission.
Fiber Ambient temperature [–40 to +70 °C –40 to +158 °F in previous model]
Options More flexible! R4

–55 to +80 °C 1.2 times


more than
Bending radius [Previous model is R25 mm R0.984 in]

–67 to +176 °F R4 mm
previous model
Semi-custom
fibers
1/6
of that of

R0.157 in
previous model

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers Integrated high-precision plug More bendable!


FX-500
series The centering precision of
Bending durability [Previous model is 1,000 times]
FX-100 the fiber core attached to the

10 million times 10,000 times


series
inserting plug is doubled.
more than previous model
As the insertion precision is
increased, the variation among * ‌Bending conditions
INDEX Bending radius: R10 mm R0.394 in,
units can be greatly suppressed.
● Centering precision: within ±40 µm Reciprocating bending 180°
11

New product
introduction
Tough
Fiber

Fiber
Selection
Guide

Model
Choose
by shape/
application
How to read
LIST OF FIBERS Model No.
Earlier models
comparison
table
Thru-beam type (one pair set)
Sensing range (mm in) Beam axis
Bending Fiber FX-101 Beam position/ Optical
Shape of fiber head U-LG Ambient Fibers
Type Model No. radius cable (Upper value) axis dia. Inclination transmission Protection temp. Dimensions
(mm) FX-500 series LONG
(mm) length FAST FX-102 (mm) of beam l o ss Super
H-SP (Lower value) axis Quality
7RXJK STD 810 31.890 Threaded
M3 R2 400 15.748 650 25.591 135 5.315 ø0.5 Type
M3

FT-30 Bending
Threaded

HYPR 210 8.268 400 15.748 Square Head


12 durability 1,350 53.150 75 2.953 Type
P.48
7RXJK STD 2,200 86.614
M4 R4 1,200 47.244 1,700 66.929 320 12.598
Cylindrical
Type
M4

FT-40 Bending 530 20.866 870 34.252


ø1
HYPR
15 durability (Note) 3,600 141.732 190 7.480 150 μm –55 to Sleeve
2m ±10 % IP67
7RXJK STD 810 31.890 /±2° +80 °C
ø1.5 R2 400 15.748 650 25.591 135 5.315 ø0.5 Flat
ø1·5

FT-S20 Type
Cylindrical

Bending HYPR 210 8.268 400 15.748


10 durability 1,350 53.150 75 2.953 Small
P.52 Spot
7RXJK STD 2,200 86.614
ø3 R4 1,200 47.244 1,700 66.929 320 12.598
FT-S30 ø1 Narrow
ø3

Bending HYPR 530 20.866 870 34.252 Beam


10 durability (Note) 3,600 141.732 190 7.480
Wide
Note: The fiber cable length practically limits the sensing range. Beam
Convergent
Reflective
Reflective type Type
Retroreflective
Sensing range (mm in) (Note) Beam axis Type
Bending Fiber FX-101 position/ Optical Chemical / Oil-
Shape of fiber head U-LG Ambient resistant
Type Model No. radius cable (Upper value) Inclination transmission Protection Dimensions
(mm) FX-500 series LONG temp.
(mm) length FAST FX-102 of beam loss Heat-
H-SP (Lower value) axis resistant

7RXJK Vacuum-
M3 resistant
M3

FD-30
STD 330 12.992 Liquid Leak /
12 R2 160 6.299 250 9.843 45 1.772 Liquid Detection
Bending P.56
80 3.150 155 6.102
Threaded

7RXJK HYPR
M4 durability 600 23.622 25 0.984
M4

FD-40
14 150 μm –55 to Fiber
2m ±10 % IP67 Options
7RXJK STD 900 35.433 /±3° +80 °C
M6
520 20.472 740 29.134 140 5.512
M6

FD-60 260 10.236 420 16.535


P.57
HYPR
17 R4 1,550 61.024 90 3.543
Bending STD Semi-custom
7RXJK 330 12.992
Cylindrical

ø3 durability 160 6.299 fibers


250 9.843 45 1.772
FD-S30 P.64
ø3

HYPR 80 3.150 155 6.102


10 600 23.622 25 0.984
Note: The sensing range is specified for white non-glossy paper. Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
12

Threaded Type
New product
introduction
Tough
Fiber

It is a standard fiber which is mounted using nuts. It


Fiber
Selection has reasonable pricing while drastically improving
Guide
flexing performance. FT-42
Model
With the lens installable type, long distance sensing and
Choose
by shape/ microscopic object sensing is possible by installing a lens.
application
A protective tube and a sturdy stainless jacket type that <Thru-beam type> F ‌ T-31/31W/43/42/42W
How to read
Model No
prevents disconnection are also prepared. FT-45X/R40
Earlier models
comparison <Reflective type> FD-31/41/62/61/R60
table

Stainless steel fittings are used for the fiber More user-friendly, high quality fiber
head of all models. Improved centering accuracy
Fibers
● Clearly conforms to RoHS SUS The beam axis deviation of each unit is kept
Super
Quality
● Can be used for secondary battery within ±3º and the beam axis centering accuracy
Threaded ● Improved mounting strength is kept within ±150 μm.
Type
Square Head
* Some models not included (FT-140) (Within ±5º and ±90 μm for ultra small diameter fibers)
Type ● Makes beam axis adjustment easier
Cylindrical Coaxial type FD-□G□ in which high- ● Improves mounting hole machining accuracy
Type
precision positioning can be achieved. ● Improves sensing accuracy
Sleeve
It is a coaxial fiber that encloses the circumference of
Flat
Type the emitter fiber at the center with the receiver fiber.
Small
Spot
This is suitable for high-precision positioning. It can
Narrow perform sensing without affecting the approach
Beam
direction of the work. Improved specularity
Wide
Beam High precision polishing is accomplished by
Convergent
Reflective Supports spot using the PCTC polishing technique.
Type
Retroreflective lenses and zoom The specularity of the end face of the fiber is
Type
lenses! 5 times greater.
Chemical / Oil-
resistant ● Light intensity is increased, enabling stable sensing.
Heat-
resistant
Vacuum-
LIST OF FIBERS
resistant
Liquid Leak /
Thru-beam type (one pair set)
Liquid Detection
Fiber Sensing range (mm in) (Note 1) Beam axis
Bending cable FX-101 Beam position/
Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) axis dia. Inclination Protection temp. Dimensions
(mm) : FX-500 series LONG
(mm) FAST FX-102 (mm) of beam
Fiber Free-cut
Options H-SP (Lower value) axis
7RXJK R2 STD 770 30.315
M3 315 12.402 550 21.654 130 5.118 150 μm –55 to
FT-31 Bending 210 8.268 340 13.386
HYPR /±2° +80 °C
12 durability 1,350 53.150 70 2.756
M3

Semi-custom ø0.5
fibers STD 590 23.228
M3 260 10.236 440 17.323 80 3.150 150 μm –40 to
FT-31W R1 HYPR 150 5.906 240 9.449 /±3° +60 °C
12 990 38.976 53 2.087
Lens mountable STD 2,800 110.236
Fiber M4 1,400 55.118 2,100 82.677 350 13.780
Dimensions FT-43 770 30.315 970 38.189 ø1.5
P.48
R4 2 m HYPR
Thru-beam 15 (Note 2) 3,600 141.732 240 9.449 150 μm –55 to
Type Bending
Lens mountable 7RXJK STD 2,050 80.709 /±2° +80 °C
Retroreflective M4 durability 1,130 44.488 1,600 62.992 300 11.811
Type FT-42
Threaded

HYPR 530 20.866 800 31.496


15 (Note 2) 3,600 141.732 190 7.480
Reflective IP67
Type Lens mountable STD 1,900 74.803
M4 800 31.496 150 μm –40 to
1,400 55.118 260 10.236
R1
M4

Others FT-42W 490 19.291 720 28.346


HYPR /±3° +60 °C
15 3,300 129.921 160 6.299
ø1
Lens mountable, Stainless-jacketed STD 1,600 62.992(Note 2)
M4 1,200 47.244 1,600 62.992(Note 2) 340 13.386
FT-45X R4 1m
HYPR 630 24.803 920 36.220 P.49
Amplifiers 20 (Note 2) 1,600 62.992 200 7.874 150 μm –55 to
Lens mountable
15 7RXJK STD 1,750 68.898 /±2° +80 °C
FX-500
Long range Elbow

930 36.614 1,500 59.055 270 10.630


series FT-R40 500 19.685 740 29.134 P.51
R4 2 m HYPR
FX-100 M4 (Note 2) 3,600 141.732 160 6.299
series Bending
With expansion lens STD 19,600 771.654(Note 2)
M14 7RXJK durability (Note 2) 19,600 771.654 19,600 771.654(Note 2) 14,000 551.181 –40 to
M14

FT-140 16,000 629.921


19,600 771.654 ø10 ― P.48
10 m HYPR (Note 2) +70 °C
40 (Note 2) 19,600 771.654 6,300 248.031
INDEX Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
13

Application FIBER OPTIONS New product


introduction
Detecting a presence of a workpiece Lens Lens Tough
(For thru-beam type fiber) (For reflective type fiber) Fiber
FD-32G
P.42 P.43


Fiber
Selection
Guide

Model
Protective tube P.45


Choose
·FTP-□ by shape/
application
·FDP-□
How to read
Model No.
Earlier models
LIST OF FIBERS comparison
table

Reflective type
Fiber Sensing range (mm in) (Note 1, 2) Beam axis
Bending cable position/ Fibers
Shape of fiber head FX-101 Ambient
Type Model No. radius length U-LG (Upper value) Inclination Protection Dimensions
(mm) FX-500 series LONG temp. Super
(mm) : FAST FX-102 of beam Quality
Free-cut H-SP (Lower value) axis Threaded
STD 290 11.417 Type
M3
7RXJK R2 125 4.921 220 8.661 35 1.378 150 μm –55 to Square Head
FD-31 Bending 80 3.150 140 5.512
HYPR /±3° +80 °C Type
12 durability 515 20.276 25 0.984
IP67 Cylindrical
STD 180 7.087 Type
M3 80 3.150 140 5.512 15 0.591 –40 to
FD-31W R1 2 m HYPR 45 1.772 60 2.362 ―
+60 °C Sleeve
12 330 12.992 12 0.472
P.56 Flat
Coaxial, Lens mountable 7RXJK STD 380 14.961 Type
M3 R2 200 7.874 270 10.630 70 2.756
FD-32G Bending 95 3.740 190 7.480 ― Small
17 HYPR
durability 650 25.591 27 1.063 –55 to Spot
M3

Coaxial, Lens mountable, STD 410 16.142 +80 °C Narrow


Stainless-jacketed 200 7.874 Beam
360 14.173 75 2.953
M3 FD-32GX R2 1 m HYPR 100 3.937 210 8.268 ―
Wide
18 (Note 3) 630 24.803 30 1.181 Beam
IP40
Coaxial, Lens mountable STD 130 5.118 Convergent
Ultra-small diameter

M3 48 1.890 –40 to Reflective


110 4.331 20 0.787 Type
FD-EG30 30 1.181 70 2.756 ― P.58
HYPR +70 °C Retroreflective
16 170 6.693 9 0.354 Type
Coaxial, Lens mountable
R4 500 mm
STD 45 1.772
M3 Chemical / Oil-
20 0.787 35 1.378 7 0.276 –20 to resistant
FD-EG31 12 0.472 25 0.984 ― P.59
HYPR +60 °C
16 85 3.346 3.5 0.138 Heat-
resistant
7RXJK STD 290 11.417
M4 R2 125 4.921 220 8.661 35 1.378 150 μm –55 to Vacuum-
FD-41 Bending 80 3.150 140 5.512 resistant
HYPR /±3° +80 °C
14 durability 515 20.276 25 0.984 Liquid Leak /
IP67 P.56 Liquid Detection
STD 630 24.803
M4 270 10.630 –40 to
430 16.929 80 3.150
FD-41W R1 150 5.906 ―
Threaded

HYPR 230 9.055 +60 °C


14 900 35.433 45 1.772
M4

Coaxial, Lens mountable 7RXJK STD 380 14.961 Fiber


M4 R2 200 7.874 270 10.630 70 2.756 –55 to Options
FD-42G Bending 95 3.740 190 7.480 ―
HYPR +80 °C
25 durability 650 25.591 27 1.063
IP40
Coaxial, Lens mountable STD 340 13.386
M4 150 5.906 280 11.024 45 1.772 –40 to Semi-custom
FD-42GW R1 90 3.543 140 5.512 ― fibers
HYPR +60 °C
25 670 26.378 25 0.984
M6
2 m STD 1,000 39.370
520 20.472 940 37.008 170 6.693
FD-62 340 13.386 450 17.717 Fiber
HYPR
17 R4 1,500 59.055 110 4.331 150 μm –55 to Dimensions
Bending P.57
7RXJK STD 840 33.071 /±3° +80 °C Thru-beam
M6 durability Type
450 17.717 670 26.378 120 4.724
FD-61 200 7.874 410 16.142 IP67
HYPR Retroreflective
17 1,400 55.118 70 2.756 Type

M6
STD 630 24.803 Reflective
270 10.630 430 16.929 80 3.150 –40 to Type
FD-61W R1 HYPR 150 5.906 230 9.055

+60 °C
17 900 35.433 45 1.772 Others
M6

Coaxial 7RXJK STD 800 31.496


M6 R4 420 16.535 650 25.591 120 4.724
FD-61G Bending 200 7.874 350 13.780 ―
HYPR
17 durability 1,100 43.307 60 2.362
IP40 Amplifiers
Stainless-jacketed STD 500 19.685
M6 280 11.024 410 16.142 75 2.953 –55 to
FD-64X R4 1 m HYPR 160 6.299 220 8.661

+80 °C
P.58 FX-500
series
22 670 26.378 50 1.969
FX-100
7RXJK STD 600 23.622
15 R4 series
Elbow

290 11.417 550 21.654 110 4.331 150 μm


FD-R60 Bending 2 m HYPR 190 7.480 240 9.449
IP67 P.63
/±3°
M6 durability 1,100 43.307 65 2.559
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper. INDEX
3) The allowable cutting range is 700 mm 27.559 in from the end that the amplifier inserted.
7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
14

Square Head Type


New product
introduction
Tough
Fiber

Compact, space-saving design brings clean installation


Fiber
Selection on the side of a conveyor belt.
Guide
As for lens compatible type fiber head, sensing range M3 Type M4 Type
Model
becomes longer when a lens is attached to the thru-
Choose
by shape/
application
beam type fiber, spot detection is achieved in case of
How to read the reflective type.
Model No
Earlier models
A lens equipped type fiber head is also available.
comparison
table Oil resistant type is also available. Please refer to p.28
Compact installation
Compact, space-saving Square head fiber heads can be installed cleanly on
Fibers
the side of a conveyor belt. The design makes it less
Super
Quality
Fiber can be installed at a minimum pitch of likely for tools and other objects to catch on the fiber
Threaded M3: 6.5 mm 0.256 in or M4: 8.5 mm 0.335 in using cable during installation.
Type
needle-nose pliers.
Square Head
Type FT-R□ / FD-R□ Standard fiber
Cylindrical Wrench Needle-nose pliers
Type Tools and other
objects can catch
Sleeve 3.5 mm 0.138 in on the fiber cable.
Flat Clean installation!
Type
Small Space is
Spot
required.
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type Introducing square R1 mm (R0.039 in) (sharp bending) fiber FT-R41W/R42W
Retroreflective
Type We now offer a sharp bending fiber featuring a low level of light fluctuations, even when bent at R1 mm R0.039 in.
Chemical / Oil-
resistant It is also available with a lens capable of long-range sensing.
Heat- FT-R41W FT-R42W FT-R42W (With lens)
resistant
Vacuum-
resistant • Resistant to dust and par-
Liquid Leak / R1 mm ticulate matter.
Liquid Detection • Tip dimensions can be
R0.039 in Lens shortened.
Fiber head

Fiber
Options

Full-protection type  FT-R60Y (Square head type M6 / thru-beam type)


Semi-custom High environmental Less susceptibility to oil Resistant to oil and coolant
fibers
resistance adhesion thanks to fluorine The fiber head and fiber cable are connected by
The head, nut, and washer resin the “fastening and caulking” method without using
Fiber are made from rust-resistant Fibers deliver stable adhesives. This method eliminates concerns that
Dimensions SUS304. The unbreakable detection, since the sensing adhesives will absorb moisture in high-humidity
Thru-beam
Type tough fiber with high part is sealed with fluorine environments and damage the fiber. The enclosure
Retroreflective durability is covered in a resin, which does not allow achieves IP68G
Type
Reflective
fluorine resin tube. The fiber oil penetration. Additionally, protection, so the
Type head is also covered with a the detection part features fiber can be installed
Others fluorine resin component, a convex design made of around metal
achieving a high level of fluorine resin, achieving processing machines
environmental resistance. lower friction than glass. shrouded in the oil
Amplifiers
mist.
FX-500 Test oil Product
series
M6 Lubricating oil Velocite Oil No. 3
FX-100
series Yushiron Cut Abas KZ201
Non-water-soluble cutting oil
Yushiron Cut UH75
Syntilo 9954 (10% diluted)
Water-soluble cutting oil
Stainless
Yushiroken S50N (2% diluted)
INDEX steel Alcohol-based neutral detergent Super Teepol
Fluorine resin (SUS304) Less susceptible to oil
(PFA) *Yushiron and Yushiroken are registered trademarks of Yushiro
adhesion than glass
Chemical Industry Co., Ltd.
15

Cable-protection type FT-R44Y / FD-R61Y Even stronger than tough fiber


New product
FT-R44Y (Square head type M4 / FD-R61Y (Square head type M6 /
The tough fiber has been reinforced by introduction
thru-beam type) reflective type) covering it with a fluorine resin tube so that Tough
it can be used even in harsh environments Fiber
Compatible with
optional lens where oils and solvents are used. The fiber
Stainless
steel
cable will not harden or break, even if it is
(SUS304) splashed with oil. Fiber
Selection
M6 Guide
Protective structure IP67 Model
M4 Fluorine resin
(PFA)
The head, nut, and washer are made
from rust-resistant SUS304. Choose
by shape/
application
LIST OF FIBERS How to read
Model No.
Thru-beam type (one pair set) Earlier models
comparison
Fiber Sensing range (mm in) (Note 1) table
Beam axis
Bending cable FX-101
Shape of fiber head U-LG dia. Ambient
Type Model No. radius length (Upper value) (Fiber Core) Protection temp. Dimensions
(mm) FX-500 series
: LONG
(mm) FAST FX-102 (mm)
Free-cut H-SP (Lower value) Fibers
7RXJK R2 STD 580 22.835 Super
M3   270 10.630 440 17.323 100 3.937
M3

FT-R31 Bending 160 6.299 340 13.386 ø0.5 Quality


HYPR
W5.5×H8×D16 durability   1,000 39.370 55 2.165 -55 to Threaded
IP67 Type
Lens mountable 7RXJK R4 STD 1,600 62.992 +80 °C
M4   720 28.346 210 8.268
FT-R43 1,100 43.307 Square Head
Bending HYPR 430 16.929 640 25.197 Type
W7×H9×D13.5 durability   3,000 118.110 130 5.118 Cylindrical
ø1 P.51
STD 1,800 70.866 Type
M4
  800 31.496 1,400 55.118 250 9.843
Square head

FT-R41W 460 18.110 710 27.953


HYPR Sleeve
W7×H9×D13.9   3,200 125.984 150 5.906 -40 to
R1
M4

IP40 Flat
With expansion lens
M4
2m STD 3,600 141.732(Note 2) +60 °C
  2,200 86.614 3,500 137.795 510 20.079 Type
FT-R42W 1,300 51.181 2,000 78.740 ø2.2
HYPR Small
W7×H9×D14.4   3,600 141.732
(Note2) 460 18.110 Spot
Cable-protection type
7RXJK STD 1,600 62.992 Narrow
Compatible with lens
  720 28.346 1,100 43.307 210 8.268 IP67 Beam
FT-R44Y 430 16.929 640 25.197 ø1
R4 HYPR (Note 3)
W7×H9.5×D15.5   3,000 118.110 130 5.118 -55 to Wide
Bending P.52 Beam
Full-protection type 7RXJK STD 3,600 141.732(Note 2) +80 °C
durability   2,100 82.677 3,600 141.732 (Note 2) 690 27.165 Convergent
M6

FT-R60Y HYPR 1,260 49.606 1,890 74.409 ø3.5 IP68G Reflective


Type
W10×H11×D21.2   (Note2) 3,600 141.732 400 15.748
Retroreflective
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Type
2) The fiber cable length practically limits the sensing range. Chemical / Oil-
3) The fiber part is oil-resistant. resistant
Reflective type Heat-
resistant
Fiber Sensing range (mm in) (Note 1, 2)
Beam axis Vacuum-
Bending cable FX-101
Shape of fiber head U-LG dia. Ambient resistant
Type Model No. radius length (Upper value) (Fiber Core) Protection temp. Dimensions
(mm) : FX-500 series LONG Liquid Leak /
(mm) FAST FX-102 (mm) Liquid Detection
Free-cut H-SP (Lower value)
Coaxial, Lens mountable
M3
7RXJK R2
STD
  170 6.693
310 12.205
260 10.236 45 1.772
Emitter
-55 to
FD-R31G Bending 85 3.346 ø0.5
2m HYPR 150 5.906 +80 °C Fiber
W5.5×H8×D16   530 20.866
durability 27 1.063
Options
Coaxial, Lens mountable STD 110 4.331 Emitter
M3   45 1.772 92 3.622 20 0.787
FD-R32EG 30 1.181 68 2.677 ø0.25
HYPR
W5.5×H8×D16   170 6.693 9 0.354 -40 to
M3

IP40 Semi-custom
Coaxial, Lens mountable STD 90 3.543 Emitter +70 °C fibers
R4 500mm  HYPR
M3 38 1.496 70 2.756 17 0.669
FD-R34EG
Square head

23 0.906 60 2.362 ø0.175


W5.5×H8×D16   130 5.118 7 0.276
P.63
Coaxial, Lens mountable STD 44 1.732 Emitter
M3   19 0.748 33 1.299 7 0.276 -20 to Fiber
FD-R33EG 11 0.433 ø0.125 Dimensions
HYPR 22 0.866 +60 °C
W5.5×H8×D16   84 3.307 3 0.118 Thru-beam
Type
M4 7RXJK R2 STD
  210 8.268
430 16.929
320 12.598 60 2.362 Retroreflective
M4

FD-R41 Bending 100 3.937 170 6.693 ø0.75 IP67


HYPR Type
W7×H9×D13.5 durability   710 27.953 34 1.339 -55 to
Reflective
Cable-protection type 7RXJK R4 2m STD 610 24.016 +80 °C Type
  280 11.024 435 17.126 85 3.346 IP67
M6

FD-R61Y Bending 160 6.299 185 7.283



HYPR (Note 3) Others
W10×H11×D15.5 durability   990 38.976 50 1.969
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.
3) The fiber part is oil-resistant.
FIBER OPTIONS Amplifiers
FX-500
Lens (For thru-beam type fiber) P.42 Lens (For square head M3 reflective fiber) P.43 series

FX-100
series

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
16

Cylindrical Type
New product
introduction
Tough
Fiber

Has a slender shape which can be mounted in narrow


Fiber
Selection locations using set screws.
Guide
Line up that includes ultra-thin fibers with ø0.25 mm tips.
Model FD-S31
FT-S32
Choose
by shape/
application
How to read
Model No <Thru-beam type> FT-S21/S21W/S31W
Earlier models
comparison
table
<Reflective type> FD-S32/S31
● User-friendly, high quality fiber
● Improved centering accuracy and specularity
Fibers
Super
Quality
Threaded
Stainless steel fittings are used for the fiber
Type head of all models.
Square Head
Type
Cylindrical
● Clearly conforms to RoHS
Type
● Can be used for secondary battery
Sleeve
● Improved mounting strength
Flat
Type
Small
Spot
Narrow
Beam LIST OF FIBERS
Wide
Beam Thru-beam type (one pair set)
Convergent
Reflective Fiber Sensing range (mm in) (Note 1) Beam axis
Type
Bending cable FX-101 Beam axis position/
Retroreflective Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) dia. Inclination Protection Dimensions
Type (mm) : FX-500 series LONG temp.
(mm) FAST FX-102 (mm) of beam
Chemical / Oil- Free-cut
resistant H-SP (Lower value) axis
7RXJK STD 210 8.268
Heat- ø1 90 3.543 160 6.299 40 1.575
ø1

resistant FT-S11 500 mm


60 2.362 90 3.543 ø0.25 ―
R2 HYPR
Vacuum- 6 350 13.780 19 0.748 –55 to
resistant Bending
7RXJK STD 770 30.315 +80 °C
Liquid Leak / ø1.5 durability 315 12.402 550 21.654 130 5.118 150 μm
Liquid Detection FT-S21 210 8.268 340 13.386
IP67
HYPR /±2°
10 1,350 53.150 70 2.756
ø1·5

ø0.5
STD 590 23.228
ø1.5 260 10.236 440 17.323 80 3.150 150 μm –40 to
Fiber
FT-S21W R1 HYPR 150 5.906 240 9.449 /±3° +60 °C
P.52
Options 10 990 38.976 53 2.087
With lens, Long sensing range 2m STD 3,600 141.732(Note 2)
ø2.5 R10 3,100 122.047 3,600 141.732(Note 2) 1,100 43.307 –40 to
ø2·5

FT-S32 ø2 ― IP40
Cylindrical

Bending HYPR 1,800 70.866 3,000 118.110 +70 °C


8 durability (Note 2) 3,600 141.732 600 23.622
Semi-custom
fibers STD 1,900 74.803
ø3 800 31.496 1,400 55.118 260 10.236 150 μm –40 to
R1
ø3

FT-S31W 490 19.291 720 28.346


ø1
HYPR /±3° +60 °C
10 3,300 129.921 160 6.299
Fiber Narrow beam ø0.125mm 7RXJK STD 30 1.181
Side-view Ultra-small diameter

ø0.25 ø3
Dimensions 15 0.591 24 0.945 6 0.236
FT-E13 8 0.315 19 0.748 ø0.125
― IP67
Thru-beam
Sleeve part
5 15 HYPR
cannot be bent. R2 52 2.047 2 0.079 –40 to
Type
ø3

Bending P.49
Narrow beam ø0.25mm
ø0.4 ø3 7RXJK 1m STD 160 6.299 +70 °C
Retroreflective durability 75 2.953 125 4.921 22 0.866 ø0.25
Type FT-E23 42 1.654 80 3.150

Sleeve part
5 15 HYPR
Reflective cannot be bent. 270 10.630 13 0.512
Type
ø4 7RXJK STD 3,600 141.732(Note 2)
R4 3,500 137.795 3,600 141.732(Note 2) 1,000 39.370 –40 to
Others
ø4

3 FT-V40 Bending 2,400 94.488 3,100 122.047


ø2.5 ― IP50 P.53
2m HYPR +60 °C
25 durability (Note 2) 3,600 141.732 850 33.465
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
Amplifiers
FX-500
series
FX-100
series

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
17

New product
introduction
Tough
Fiber

Fiber
Selection
Guide

Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table

Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type

Sleeve

Flat
Type
Small
Spot
Narrow
Beam
Wide
Reflective type Beam
Convergent
Fiber Sensing range (mm in) (Note 1, 2) Beam axis Reflective
Type
Bending cable FX-101 position/
Shape of fiber head U-LG Ambient Retroreflective
Type Model No. radius length (Upper value) Inclination Protection Dimensions
(mm) : FX-500 series LONG temp. Type
(mm) FAST FX-102 of beam
Free-cut Chemical / Oil-
H-SP (Lower value) axis resistant
7RXJK STD 130 5.118 Heat-
ø1.5 R2 80 3.150 110 4.331 25 0.984
ø1·5

FD-S21 1m ― IP40 P.63 resistant


Bending HYPR 37 1.457 70 2.756
10 durability 190 7.480 11 0.433 –55 to Vacuum-
resistant
7RXJK STD 790 31.102 +80 °C
ø3 R4 420 16.535 660 25.984 120 4.724 150 μm Liquid Leak /
FD-S32 Bending 220 8.661 345 13.583 Liquid Detection
HYPR /±3°
15 durability 1,200 47.244 75 2.953
STD 630 24.803
ø3 270 10.630 430 16.929 80 3.150 –40 to
FD-S32W R1 HYPR 150 5.906 230 9.055
― IP67
+60 °C
Fiber
15 900 35.433 45 1.772 Options
ø3

P.64
Cylindrical

7RXJK 2m STD 290 11.417


ø3 R2 125 4.921 220 8.661 35 1.378 150 μm –55 to
FD-S31 Bending 80 3.150 140 5.512
HYPR /±3° +80 °C Semi-custom
10 durability 515 20.276 25 0.984
fibers
Coaxial STD 340 13.386
ø3 150 5.906 280 11.024 45 1.772
FD-S33GW R1 HYPR 90 3.543 140 5.512

15 670 26.378 25 0.984 –40 to Fiber
STD 29 1.142 +60 °C Dimensions
Ultra-small diameter

ø1.5 ø0.48 12 0.472 25 0.984 5 0.197


ø1·5

FD-E13 7 0.276 15 0.591


― IP40 Thru-beam
15 3 HYPR Type
Sleeve part cannot be bent. 50 1.969 2 0.079
R4 1m
STD 120 4.724
P.58 Retroreflective
ø3 ø0.63 Type
55 2.165 80 3.150 20 0.787 –40 to
ø3

FD-E23 30 1.181 70 2.756 ― Reflective


15 5 HYPR +70 °C Type
Sleeve part cannot be bent. 170 6.693 9 0.354
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Others
2) The sensing range is specified for white non-glossy paper.

Amplifiers
FX-500
series
FX-100
series

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
18

Sleeve
New product
introduction
Tough
Fiber

It is suitable for sensing in narrow locations and sensing


Fiber
Selection minute objects because the fiber tip is a thin sleeve. FD-41S
Guide
The 40 mm sleeve type can be bent in any direction.
Model
Choose FT-42S
by shape/
application
How to read
Model No <Thru-beam type> FT-E13 / FT-E23 Ultra-small diameter fiber
Earlier models
comparison
table Centering accuracy of 1/10 mm or less
Ultra-small diameter fibers with a compact head ensure precision centering accuracy* to stably detect minute parts.

Fibers
A B * Tolerance of A + Tolerance of B + Tolerance of C = ±0.09 mm
Super
Quality
Threaded C
Type
Square Head
Type Dimensions UNCLEAR Dimensions CLEAR
Cylindrical Example: FT-E13
Type Screw
Dimensions unclear Dimensions unclear ø3 mm+0.05 +0.002
New ø0.5 mm+0.05 +0.002 ø0.118 in 0
Sleeve Previous ø0.020 in 0
Screw Dimensions clear
general standard
Flat fiber
Type fiber
Small
Spot
Narrow
Beam Extra clearance needs to be added when
Wide designing and machining the mounting hole Highly accurate design and machining are
Beam
Convergent due to unclear dimensions. possible due to clear mounting hole dimensions.
Reflective As a result, mounting variation increases As a result, mounting variation is minimal,
Type
Retroreflective and the beam axis deviates, resulting in a improving sensing accuracy. In addition to this, as
Type decrease in sensing accuracy or causing the the beam axis alignment is not affected when the
Chemical / Oil- sleeve to bend or break. fiber is changed, readjustment is not necessary.
resistant
Heat-
resistant
Vacuum- Minute sensing only possible with ultra small fiber
resistant
Liquid Leak / Detection of fine-pitch connector pins Detection of tiny chips
Liquid Detection
Ultra-small diameter fiber Fiber can be installed with
with ø0.125 mm ø0.005 in only the ø0.25 mm ø0.010
Fiber beam axis is able to detect in sleeve close to the minute
Options
FT-E13
the insertion or bending of section.
fine-pitch connector pins.
FT-E13
Semi-custom
fibers

Stainless steel fittings are used for the fiber


Fiber
Dimensions head of all models.
Thru-beam
Type ● Clearly conforms to RoHS
Retroreflective ● Can be used for secondary battery
Type
Reflective
● Improved mounting strength
Type

Others
Application FIBER OPTION
Fiber bender

Amplifiers ·FB-1 The fiber bender bends the


FX-500 sleeve part of the fiber head
series
FX-100
at the proper radius.
series

Note: Do not bend the sleeve part of any side-view type fiber or ultra-
small diameter head type fiber.
INDEX
19

LIST OF FIBERS New product


introduction
Thru-beam type (one pair set) Tough
Fiber
Fiber Sensing range (mm in) (Note 1, 2)
Bending cable FX-101 Beam
Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) axis dia. Protection Dimensions
(mm) : FX-500 series LONG temp.
(mm) FAST FX-102 (mm) Fiber
Free-cut Selection
H-SP (Lower value) Guide
Sleeve 40mm
M3 7RXJK R2 STD 740 29.134
315 12.402 Model
550 21.654 130 5.118
M3

FT-31S Bending 195 7.677 ø0.5


Threaded

ø0.88 durability HYPR 340 13.386 Choose


10 1,220 48.031 63 2.480 by shape/
(Note 3) –55 to
P.48 application
Sleeve 40mm
M4 7RXJK R4 2m STD 2,050 80.709 +80 °C How to read
1,130 44.488 1,600 62.992 300 11.811 Model No.
M4

FT-42S Bending 530 20.866 800 31.496 ø1


ø1.48
12 durability HYPR Earlier models
(Note 3) (Note 2) 3,600 141.732 190 7.480 comparison
IP67 table
Narrow beam ø0.125mm 7RXJK STD 30 1.181
Ultra-small diameter

ø0.25 ø3
15 0.591 24 0.945 6 0.236
FT-E13 8 0.315 19 0.748 ø0.125
Sleeve part
5 15 HYPR
cannot be bent. R2 52 2.047 2 0.079 –40 to
ø3

Bending P.49
Narrow beam ø0.25mm
ø0.4 ø3 7RXJK 1m STD 160 6.299 +70 °C Fibers
durability 75 2.953 125 4.921 22 0.866
FT-E23 42 1.654 80 3.150 ø0.25 Super
Sleeve part
5 15 HYPR
cannot be bent. 270 10.630 13 0.512 Quality
ø1 ø2 7RXJK STD 1,000 39.370 Threaded
R4 450 17.717 880 34.646 160 6.299 Type
1.1 ø0.75 P.52
FT-V23
Cylindrical

Sleeve part Bending HYPR 280 11.024 400 15.748 Square Head
cannot be bent. 20 15 durability 1,800 70.866 90 3.543 –55 to Type
ø1 ø2 7RXJK STD 550 21.654 +80 °C
R2 Cylindrical
1 240 9.449 480 18.898 95 3.740 Type
ø2

FT-V25 Bending
Side-view

Sleeve part HYPR 140 5.512 260 10.236


cannot be bent. 15 15 durability 900 35.433 45 1.772 Sleeve
ø1 ø2
ø0.5 IP30
2m STD 230 9.055
110 4.331 200 7.874 35 1.378 –40 to Flat
Sleeve part
1 FT-V24W R1 HYPR 60 2.362 90 3.543 +60 °C
P.53 Type
cannot be bent. 15 15 380 14.961 20 0.787 Small
ø1.5 ø2.5 STD 1,200 47.244 Spot
7RXJK R4 680 26.772 1,000 39.370 180 7.087 –55 to
ø2·5

1.3 ø1.0 Narrow


FT-V30 Bending 340 13.386 480 18.898 Beam
Sleeve part HYPR +80 °C
cannot be bent. 20 15 durability 2,200 86.614 100 3.937 Wide
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Beam
2) The fiber cable length practically limits the sensing range. Convergent
Reflective
3) Bending radius of sleeve part is R10 mm R0.394 in or more. Type
Retroreflective
Type
Reflective type
Chemical / Oil-
Fiber Sensing range (mm in) (Note 1, 2) resistant
Bending cable FX-101 Heat-
Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) Protection Dimensions resistant
(mm) : FX-500 series LONG temp.
(mm) FAST FX-102 Vacuum-
Free-cut H-SP (Lower value) resistant
Sleeve 15 mm STD 110 4.331 Liquid Leak /
Ultra-small
diameter

M3 ø0.8 50 1.969 80 3.150 20 0.787 –40 to Liquid Detection


R4
M3

FD-EG30S 1m 30 1.181 70 2.756 IP40 P.59


15 HYPR +70 °C
Sleeve part cannot be bent. 170 6.693 9 0.354
Sleeve 40 mm 7RXJK R2 STD 290 11.417
M4 125 4.921 220 8.661 –55 to Fiber
35 1.378
FD-41S Bending 80 3.150 140 5.512 Options
Threaded

ø1.48 durability HYPR +80 °C


12 (Note 3) 515 20.276 25 0.984
M4

P.56
Sleeve 40 mm STD 180 7.087
M4
FD-41SW
R1 80 3.150 140 5.512 15 0.591 IP67
–40 to
ø1.48 2m HYPR 45 1.772 60 2.362 +60 °C Semi-custom
12 (Note 3) 12 0.472 fibers
330 12.992
Sleeve 40 mm
M6 7RXJK R4 STD 790 31.102
420 16.535 660 25.984 130 5.118 –55 to
M6

FD-61S Bending 220 8.661 360 14.173 P.57


ø2.5 durability HYPR +80 °C
15 (Note 3) 1,200 47.244 75 2.953 Fiber
Dimensions
STD 29 1.142
Ultra-small diameter

ø1.5 ø0.48 12 0.472 Thru-beam


25 0.984 5 0.197 –40 to
ø1·5

FD-E13 7 0.276 15 0.591 Type


15 3 HYPR +60 °C
Sleeve part cannot be bent. 50 1.969 2 0.079 Retroreflective
R4 1m
120 4.724
IP40 P.58 Type
ø3 ø0.63 STD
55 2.165 80 3.150 20 0.787 –40 to Reflective
ø3

FD-E23 30 1.181 70 2.756 Type


15 5 HYPR +70 °C
Sleeve part cannot be bent. 170 6.693 9 0.354
Others
Cylindrical

Small diameter 7RXJK STD 130 5.118


15 15 R2 65 2.559 120 4.724 25 0.984 –55 to
ø3 ø1.5 2 FD-V30 Bending HYPR 35 1.378 75 2.953 +80 °C
Sleeve part cannot be bent. durability 240 9.449 14 0.551
ø3

P.64
Side-view

STD 40 1.575 Amplifiers


15 15 20 0.787 30 1.181 6 0.236 –40 to
ø3 ø1.5 2 FD-V30W R1 2m HYPR 10 0.394 20 0.787
IP30
+60 °C FX-500
Sleeve part cannot be bent. 80 3.150 2 0.079 series
7RXJK STD 220 8.661 FX-100
15 20 R4 120 4.724 210 8.268 40 1.575 –55 to series
ø5

2.3 FD-V50 Bending 75 2.953 P.65


ø5 ø2 HYPR 100 3.937 +80 °C
Sleeve part cannot be bent. durability 370 14.567 25 0.984
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper. INDEX
3) Bending radius of sleeve part is R10 mm R0.394 in or more.
7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
20

Flat Type
New product
introduction
Tough
Fiber

Since it has a thin, rectangular shape, it can be installed


Fiber
Selection in narrow locations. It is also a fiber with good workability FT-Z30H FT-Z30E FT-Z30
Guide
and can be mounted directly with screws.
Model
Choose
by shape/
application
How to read
Model No 1 point mounting Fiber guide system contributes to
Earlier models
comparison space-saving
table The sensor can be mounted on 1 point with either M2
screw or M3 screw. Metal sleeve in the enclosure helps to FT-Z□HBW and FD-Z□HBW is equipped with a fiber guide
be tightened firmly even with a single screw. feature. This enables to mount either way of top sensing
Fibers and side sensing.
Super
Quality Space-saving M2 screw
Top Sensing Side Sensing
Threaded
Type
installation
Square Head FD-Z20HBW
Type
10 mm
Cylindrical 0.394 in
Type 2 mm
0.079 in
Sleeve Boss Equipped with metal sleeve
Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent LIST OF FIBERS
Reflective
Type
Retroreflective
Thru-beam type (one pair set)
Type
Fiber Sensing range (mm in) (Note 1)
Chemical / Oil- Bending cable FX-101 Beam
resistant Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) axis dia. Protection temp. Dimensions
(mm) : FX-500 series LONG
Heat- (mm) FAST FX-102 (mm)
resistant Free-cut H-SP (Lower value)
Vacuum- Top sensing W3 × H8 × D12 7RXJK
resistant R2
FT-Z30H Bending
Liquid Leak / STD 3,600 141.732(Note 2)
Liquid Detection durability 3,500 137.795 3,600 141.732(Note 2) 1,400 55.118 P.54
Top sensing W3 × H8 × D12 HYPR 2,600 102.362 3,200 125.984
(Note 2) 3,600 141.732 810 31.890
FT-Z30HW R1
Fiber 2×3
Options Side sensing W3 × H12 × D8 7RXJK STD 3,600 141.732(Note 2)
R2 3,500 137.795 3,600 141.732(Note 2) 1,200 47.244
FT-Z30E Bending 2,400 94.488 3,200 125.984 P.53
HYPR
durability (Note 2) 3,600 141.732 740 29.134
Semi-custom Side sensing W3 × H12 × D8 2m STD 3,600 141.732(Note 2)
fibers 3,400 133.858 3,600 141.732(Note 2) 1,400 55.118
FT-Z30EW R1 HYPR 2,000 78.740 2,600 102.362 IP40 P.54
(Note 2) 3,600 141.732 630 24.803
Front sensing STD 3,600 141.732(Note 2)
W8.5 × H12 × D3 7RXJK R2 2,100 82.677
Fiber 3,600 141.732(Note 2) 710 27.953
P.53
FT-Z30
Flat

Dimensions Bending HYPR 1,200 47.244 2,300 90.551


durability (Note 2) 3,600 141.732 410 16.142 –40 to
Thru-beam ø2
Type Front sensing STD 3,300 129.921 +60 °C
W8.5 × H12 × D3 1,500 59.055 3,200 125.984 540 21.260
Retroreflective FT-Z30W 1,000 39.370 1,800 70.866 P.54
Type
HYPR
(Note 2) 3,600 141.732 280 11.024
Reflective Front sensing STD 1,500 59.055
Type W10 × H7 × D2 620 24.409 1,100 43.307 280 11.024
FT-Z20W 420 16.535 730 28.740 ø1.5
Others HYPR
(Note 2) 1,600 62.992 130 5.118
P.53
Fiber bending type 1m STD 670 26.378
W2 × H10 × D10 260 10.236 570 22.441 100 3.937
FT-Z20HBW R1 320 12.598 ø0.5 IP67
With boss

HYPR 180 7.087


1,100 43.307 55 2.165
Amplifiers Front sensing
W14 × H7 × D3.5 STD 3,300 129.921
FX-500
1,500 59.055 2,300 90.551 410 16.142
FT-Z40W 900 35.433 1,200 47.244 ø1.5 IP40
series HYPR
(Note 2) 3,600 141.732 290 11.417
FX-100 P.54
series Fiber bending type 2m STD 1,900 74.803
W3.5 × H14 × D11 800 31.496 1,400 55.118 260 10.236
FT-Z40HBW 490 19.291 720 28.346
ø1 IP67
HYPR
3,300 129.921 160 6.299
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
INDEX 2) The fiber cable length practically limits the sensing range.

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
21

New product
introduction
Tough
Fiber

Fiber
Selection
Guide

Model
Choose
by shape/
application
How to read
Model No.
Earlier models
comparison
table

Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type

Sleeve

Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Reflective type Type
Retroreflective
Fiber Sensing range (mm in) (Note 1, 2) Type
Bending cable FX-101 Chemical / Oil-
Shape of fiber head U-LG Ambient resistant
Type Model No. radius length (Upper value) Protection temp. Dimensions
(mm) : FX-500 series LONG
(mm) FAST FX-102 Heat-
Free-cut H-SP (Lower value) resistant
Front sensing STD 150 5.906 2 to 32 Vacuum-
   1 to 65 0.039 to 2.559 130 5.118 0.079 to 1.260 resistant
FD-Z20W 2 to 45 0.079 to 1.772 1 to 80
IP40
Liquid Leak /
HYPR
W10 × H7 × D2    260 10.236 5 to 13 0.197 to 0.512 0.039 to 3.150 Liquid Detection
Fiber bending type 1m STD 1 to 210 0.039 to 8.268 2 to 30
   2 to 85 0.079 to 3.346 1 to 180 0.039 to 7.087 0.079 to 1.181
FD-Z20HBW 2 to 55 0.079 to 2.165 1 to 90 IP67
With boss

HYPR
W2 × H10 × D10    1 to 340 0.039 to 13.386 3 to 15 0.118 to 0.591 0.039 to 3.543 –40 to Fiber
Flat

Front sensing
R1 440 17.323 +60 °C
P.65 Options
STD 1 to 74
  190 7.480 390 15.354 0.039 to 2.913
FD-Z40W 1 to 120 0.039 to 4.724 200 IP40
HYPR
W14 × H7 × D3.5   790 31.102 2 to 35 0.079 to 1.378 7.874
Fiber bending type 2m 540 21.260 Semi-custom
STD 1 to 90 fibers
  260 10.236 470 18.504 0.039 to 3.543
FD-Z40HBW 1 to 160 0.039 to 6.299 0.5 to 240 IP67
HYPR
W3.5 × H14 × D11   760 29.921 2 to 50 0.079 to 1.969 0.020 to 9.449
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Fiber
2) The sensing range is specified for white non-glossy paper. Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
22

Small Spot
New product
introduction
Tough
Fiber

Sensing of minute objects can be performed by


Fiber
Selection combining the fiber and spot lens. The spot diameter
Guide
can also be changed.
Model
Choose
by shape/
application
How to read
Model No Applications
Earlier models
comparison
table
Packing detection Number of IC pins checking Discrimination of 0603 chip direction
FD-42G/42GW FX-MR6 (lens)
+
FD-EG31 FD-EG31 (fiber)
Fibers
IC
Super FX-MR5
Quality FX-MR3
Threaded
Type
Square Head Because it’s a side-view type, it can
Type
Cylindrical
be mounted even in narrow spaces.
Type

Sleeve

Flat
Type
Three optional lenses for reflective type fiber are available.
Small Perfect for chip component detection applications. FX-MR7 / MR8 / MR9
Spot
Narrow
Beam
Finest spot lens FX-MR7 Parallel light lens FX-MR9
Wide
Beam About 3 times more light received (compared to previous models) Long-range parallel light
Convergent
Reflective
Type Since there is a large difference Depending on the fiber with which it
Retroreflective
Type in the amount of light received is used, this lens creates parallel light
Chemical / Oil- in applications such as direction with a spot diameter of approximately
resistant
detection, it is easy to set a threshold ø4 mm ø0.157 in at a sensing range
Heat-
resistant that will allow stable detection. of 0 to 30 mm 0 to 1.181 in.
Vacuum-
resistant Additionally, these products offer an
Liquid Leak / S/N ratio that is 1.3 times better than
Liquid Detection
previous models.
Typical FX-501 erformance (STD mode) All models
Fiber White Black
Options
FX-MR7 + FD-R33EG 3,200 digits 1,030 digits Tightening torque 5 times (compared to previous models)
FX-MR6 (compared to previous models)
+ FD-R33EG
1,000 digits 435 digits The standard aluminum body has been changed to
Semi-custom
fibers stainless steel (SUS 303) to reduce the likelihood of
Zoom lens FX-MR8 damage from over-tightening.

Fiber
Dimensions
Variable spot diameter Standard lens outer diameter of ø4.3 mm (ø0.169 in)
Thru-beam
Type Spot diameters ranging from ø0.4 to Use of the same mounting hardware across the
Retroreflective ø3.5 mm ø0.016 to ø0.138 in can be product line means less inventory and lower costs.
Type
Reflective
achieved by combining the lens with a
Type variety of fibers.
Others

Amplifiers
FX-500
series
FX-100
series

INDEX
23

LIST OF FIBERS New product


introduction
High precision fiber & spot lens
Tough
Lens Applicable fibers Fiber
Shape of head Distance to
Spot diameter Fiber cable Bending
Designation (mm) focal point Ambient Ambient
(mm in) (Note)
Dimensions (mm in) (Note) Model No. temp. Model No. length radius Protection
temp.
Dimensions
: Free-cut (mm)
16 Fiber
–20 to Selection
ø0.1 ø0.004 FD-EG31 P.59 Guide
 ø4 P.68 +60 °C
500 mm R4 Model
–40 to
ø0.2 ø0.008 FD-EG30 P.58
 P.68 +70 °C Choose
by shape/
7RXJK R2 –55 to application
Bending +80 °C
7±0.5 –20 to FD-42G durability P.57
How to read
0.276±0.020 FX-MR6 Model No.
+60 °C –40 to
FD-42GW
2m
R1 +60 °C
Earlier models
comparison
ø0.4 ø0.016 table
7RXJK R2
Bending –55 to
FD-32G durability P.56
+80 °C
FD-32GX 1m R2
Finest spot  P.68 Fibers
15
lens –20 to
ø0.15 ø0.006 FD-EG31 P.59 Super
 P.68 +60 °C
ø4 500 mm R4 Quality
–40 to
ø0.3 ø0.012 FD-EG30 P.58 Threaded
 P.68 +70 °C Type
7RXJK R2 –55 to Square Head
Bending +80 °C Type
7.5±0.5 –40 to FD-42G durability P.57
0.295±0.020 FX-MR3 IP40 Cylindrical
+70 °C –40 to
FD-42GW
2m
R1 +60 °C
Type
ø0.5 ø0.020
7RXJK R2 Sleeve
Bending –55 to
FD-32G durability P.56 Flat
+80 °C Type
FD-32GX 1m R2
 P.68 Small
Spot
7RXJK R2 –55 to
20.2 Bending Narrow
Pinpoint spot 6±1 –40 to FD-42G +80 °C
ø0.5 ø0.020
0.236±0.039 FX-MR1 durability Beam
lens ø4 +70 °C –40 to
 P.67
FD-42GW R1 +60 °C
Wide
Beam
7RXJK R2 –55 to Convergent
27.1 ø0.7 to ø2.0 Approx.18.5 to 43 Bending Reflective
–40 to FD-42G +80 °C Type
Zoom lens ø0.028 to Approx. 0.728 to FX-MR2 durability P.57
ø7.1 ø0.079 1.693 +70 °C 2m –40 to Retroreflective
 P.67
FD-42GW R1 +60 °C
Type
Chemical / Oil-
7RXJK R2 –55 to resistant
Zoom lens ø0.5 to ø3.0 Approx.13 to 30 –40 to Bending +80 °C
W6.3 × H20.3 ø0.020 to Approx. 0.512 to FX-MR5 FD-42G durability Heat-
(Side-view type) × D10.3 ø0.118 1.181 +70 °C –40 to resistant
 P.68
FD-42GW R1 +60 °C Vacuum-
resistant
Square head type M3, Reflective type fiber & spot lens Liquid Leak /
Liquid Detection
Distance to Lens Fiber
Spot diameter
Type focal point Shape (mm in) Emitting fiber
(mm in) (Note) Model No. Shape Model No.
(mm in) (Note) Dimensions core (mm in)
ø0.125 ø0.005 FD-R33EG Fiber
ø0.1 ø0.004 Options
approx.
ø0.125 ø0.005 FD-EG31
ø0.15 ø0.006 ø0.175 ø0.007 FD-R34EG
approx.
Semi-custom
ø0.25 ø0.010 FD-R32EG fibers
ø0.2 ø0.008
approx. 15.3
0.602 ø0.25 ø0.010 FD-EG30
Finest spot 7 ± 0.5 FX-MR7
lens 0.276 ± 0.020 ø5 ø0.197
ø0.5 ø0.020 FD-R31G Fiber
Dimensions
ø0.5 ø0.020 FD-32G Thru-beam
Type
ø0.4 ø0.016 ø0.5 ø0.020 FD-32GX
approx. Retroreflective
Type
ø0.5 ø0.020 FD-42G
Reflective
Type
ø0.5 ø0.020 FD-42GW
 P.68
Others
Sensing Lens Applicable fibers
Spot diameter
Type range Shape Emitting fiber
(mm in) (Note) Model No. Model No.
(mm in) (Note) (mm in) core (mm in)
ø0.4 to ø2.0 ø0.016 to ø0.079 approx. 15 ø0.125 ø0.005 FD-R33EG, FD-EG31 Amplifiers
ø0.4 to ø2.2 ø0.016 to ø0.087 approx. 0.591 ø0.175 ø0.007 FD-R34EG
Zoom lens 10 to 30 FX-MR8 FX-500
ø0.5 to ø2.5 ø0.020 to ø0.098 approx. 0.394 to1.181
ø5 ø0.197
ø0.25 ø0.010 FD-R32EG, FD-EG30 series
ø0.8 to ø3.5 ø0.031 to ø0.138 approx.  P.68 ø0.5 ø0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW FX-100
series
10 ø0.125 ø0.005 FD-R33EG, FD-EG31
0.394 ø0.175 ø0.007 FD-R34EG
Parallel light ø4.0 ø0.157 approx. 0 to 30 FX-MR9
lens 0 to 1.181 ø5 ø0.197
ø0.25 ø0.010 FD-R32EG, FD-EG30
 P.68 ø0.5 ø0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW INDEX
Note: Spot diameter, distance to focal point and sensing range are specified for FX-500/FX-100 series.
7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
24

Narrow Beam
New product
introduction
Tough
Fiber

Since the beam is narrow, it has a feature by which it is


Fiber
Selection not easily affected by surrounding obstacles even in Aperture angle 3°
Guide
long distances.
Model

Applications
Choose
by shape/
application
How to read
Model No
Detection of a transparent tube Mapping of a wafer
Earlier models
comparison
table

FR-KZ50H FT-KV40

Fibers
Super LIST OF FIBERS
Quality
Threaded Thru-beam type (one pair set)
Type
Fiber Sensing range (mm in) (Note 1) Beam axis
Square Head Beam
Type Bending cable FX-101 axis position/
Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) dia. Inclination Protection Dimensions
Cylindrical (mm) : FX-500 series LONG temp.
Type (mm) FAST FX-102 (mm) of beam
Free-cut H-SP (Lower value) axis
Sleeve Aperture angle 2° STD 3,600 141.732(Note 2) 2,200 86.614
ø3.5 ø3.7 7RXJK
(Note 2) 3,600 141.732 3,600 141.732(Note 2) 3,600 141.732
Flat FT-KS40 3,600 141.732(Note 2) ø2.2 ― IP40
Type R2 HYPR (Note 2)
20 (Note 2) 3,600 141.732 1,200 47.244
Small Aperture angle 2° ø4 Bending STD 3,600 141.732(Note 2)
Spot 7RXJK
durability 3,600 141.732
Narrow beam

(Note 2) 3,600 141.732(Note 2)


Narrow FT-KV40 3,600 141.732(Note 2)
3 HYPR
Beam 25 (Note 2) 3,600 141.732 1,200 47.244 2,200 86.614 –40 to
3,600 141.732 ø2.5 ±0.8° P.51
Side-view

Wide Aperture angle 2° ø4 2m STD 3,600 141.732(Note 2) (Note 2) +60 °C


Beam (Note 2) 3,600 141.732 3,600 141.732 (Note 2)
Convergent
FT-KV40W R1 HYPR 3,100 122.047 IP30
3
Reflective (Note 2) 3,600 141.732 940 37.008
Type 25
Retroreflective
Aperture angle 3° 1.5 × 2 7RXJK STD 1,600 62.992
R2 710 27.953 1,200 47.244 135 5.315 X±1°
Type FT-KV26
2
Bending HYPR 440 17.323 560 22.047 ø1 Z±0.5°
Chemical / Oil- 20 durability 2,500 98.425 160 6.299
resistant
Heat-
resistant Retroreflective type
Vacuum- Fiber Sensing range (mm in) (Note 1, 3)
resistant Bending cable
Shape of fiber head FX-101 Ambient
Liquid Leak / Type Model No. radius length U-LG (Upper value) Protection temp. Dimensions
Liquid Detection (mm) : FX-500 series LONG
(mm) FAST FX-102
Free-cut H-SP (Lower value)
STD 100 to 1,400 3.937 to 55.118 100 to 550
Ultra-narrow polarizing

W5.2 × H9.5 × D16


100 to 990 3.937 to 38.976 100 to 1,200 3.937 to 47.244 3.937 to 21.654 –25 to
With

filter

Fiber FR-Z50HW R1 HYPR 100 to 780 3.937 to 30.709 100 to 830 IP40 +55 °C
Options W30 × H30 × D0.5 100 to 1,900 3.937 to 74.803 100 to 490 3.937 to 19.291 3.937 to 32.677
W7.5 × H2.2 × D11.2
Aperture 7RXJK STD 15 to 460 0.591 to 18.110 15 to 200
angle 3° 15 to 310 0.591 to 12.205
beam

Semi-custom 15 to 410 0.591 to 16.142 0.591 to 7.874


fibers
(emitter) FR-KZ22E 15 to 220 0.591 to 8.661 15 to 360
HYPR
15 to 570 0.591 to 22.441 15 to 100 0.591 to 3.937 0.591 to 14.173
P.55
W4 × H2 × D21.5 2m
R2 –40 to
7RXJK IP30
Side sensing Top sensing

W5.2 × H9.5 × D21 Bending


Fiber +60 °C
Narrow beam

Dimensions FR-KZ50H durability


STD 20 to 800 0.787 to 31.496 20 to 200
Thru-beam W10.6 × H28 × D10.1 20 to 300 0.787 to 11.811
Type 20 to 400 0.787 to 15.748 0.787 to 7.874
W9.5 × H25 × D5.2
7RXJK HYPR 20 to 200 0.787 to 7.874 20 to 350
Retroreflective 20 to 1,000 0.787 to 39.370 20 to 200 0.787 to 7.874 0.787 to 13.780
Type FR-KZ50E
Reflective W28 × H10.6 × D10.1
Type

Others Reflective type


Fiber Sensing range (mm in) (Note1)
Bending cable FX-101
Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) Protection temp. Dimensions
(mm) : FX-500 series LONG
Amplifiers (mm) FAST FX-102
Free-cut H-SP (Lower value)
FX-500
series W5.2 × H9.5 × D16 STD 10 to 1,100 0.394 to 43.307 10 to 200
range

10 to 650 0.394 to 25.591 –40 to


Long

10 to 1,000 0.394 to 39.370 0.394 to 7.874


FX-100 FD-Z50HW R1 2m HYPR 10 to 410 0.394 to 16.142 10 to 530 IP40 +60 °C P.65
series 10 to 2,500 0.394 to 98.425 15 to 130 0.591 to 5.118 0.394 to 20.866
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector.
INDEX Refer to P.27 or 38 for the sensing range when FR-Z50HW is used in combination with a reflector (optional).

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
25

Wide Beam
New product
introduction
Tough
Fiber

Senses a workpiece with indefinite shape or position in


the wide beam without missing. It can also be used to Fiber
Selection
Guide
discriminate shape. FT-A11 Model
Choose
by shape/
application
How to read
Applications Model No.
Earlier models
Sensing tiny moving objects Inspecting screw height Control the amount of meandering Confirming presence of slit mask comparison
table

FT-A11 FD-A16
Spot size
2 × 15mm
FT-A32 Fibers
(by a distance of 15mm)
Super
Quality
Threaded
Type
Type : Square Head
With slit mask Type
Cylindrical
Type
Type :
Without slit mask Sleeve

Flat
Type
LIST OF FIBERS Small
Spot
Thru-beam type (one pair set) Narrow
Beam
Fiber Sensing range (mm in) (Note 1)
Beam Wide
Bending cable FX-101 Beam
Shape of fiber head U-LG axis Ambient
Type Model No. radius length (Upper value) Protection Dimensions Convergent
(mm) : FX-500 series LONG dia. temp.
(mm) FAST FX-102 Reflective
Free-cut (mm) Type
H-SP (Lower value) Retroreflective
Type
7RXJK R2 STD 3,600 141.732(Note 2)
Sensing width 3,600 141.732 –40 to Chemical / Oil-
(Note 2) 3,600 141.732(Note 2)
32mm FT-A32 Bending 3,600 141.732(Note 2)
resistant
HYPR +60 °C
W5 × H69 × D20 durability (Note 2) 3,600 141.732 2,100 82.677 3,600 141.732 Heat-
(Note 2) resistant
Allows flexible wiring 3,600 141.732 3.2 × 32 Vacuum-
STD 3,600 141.732(Note 2) (Note 2) resistant
Sensing width
Wide beam

(Note 2) 3,600 141.732 3,600 141.732(Note 2) –40 to


32mm FT-A32W R1 HYPR 3,600 141.732(Note 2) +55 °C
Liquid Leak /
Liquid Detection
W5 × H69 × D20 (Note 2) 3,600 141.732 3,000 118.110

STD IP40 P.49


7RXJK 2m 3,600 141.732(Note 2)
Sensing width R2 3,600 141.732 1,900 74.803 –40 to
(Note 2) 3,600 141.732(Note 2)
11mm FT-A11 Bending 3,600 141.732(Note 2) 3,600 141.732 Fiber
HYPR (Note 2) +70 °C Options
W4.2 × H31 × D13.5 durability (Note 2) 3,600 141.732 1,100 43.307
2.2 × 11
Allows flexible wiring STD 3,600 141.732(Note 2)
Sensing width (Note 2) 3,600 141.732 3,600 141.732(Note 2) 1,700 66.929 –40 to
11mm FT-A11W R1 HYPR 3,600 141.732(Note 2) 3,400 133.858 +55 °C
W4.2 × H31 × D13.5 (Note 2) 3,600 141.732 1,300 51.181 Semi-custom
fibers
Sensing width 7RXJK STD 1,550 61.024
R2 860 33.858
Array

5.5mm 1,500 59.055 250 9.843 –55 to


FT-AL05 Bending HYPR 500 19.685 660 25.984 0.25 × 5.5 +80 °C
W5 × H15 × D15 durability 2,300 90.551 170 6.693
Fiber
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Dimensions
2) The fiber cable length practically limits the sensing range.
Thru-beam
Type
Reflective type Retroreflective
Type
Fiber Sensing range (mm in) (Note 1, 2)
Reflective
Bending cable FX-101 Type
Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) Protection temp. Dimensions
(mm) : FX-500 series LONG Others
(mm) FAST FX-102
Free-cut H-SP (Lower value)
7RXJK STD 200 7.874
R4
beam

200 7.874 200 7.874 –40 to


Wide

120 4.724
FD-A16 Bending 140 5.512 240 9.449
HYPR +60 °C
W7 × H15 × D30 durability Cannot use 75 2.953 Amplifiers
IP40 P.58
7RXJK 2m STD 530 20.866 FX-500
R2 320 12.598
Array

510 20.079 100 3.937 –55 to series


FD-AL11 Bending 180 7.087 285 11.220
HYPR +80 °C FX-100
W5 × H20 × D20 durability 670 26.378 50 1.969 series
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is specified for white non-glossy paper.

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
26

Convergent Reflective Type


New product
introduction
Tough
Fiber

It is a fiber in which the sensing distance is limited to a


Fiber
Selection specific range so it is not easily affected by the
Guide
background. It is effective when a workpiece is accu-
Model
mulated or when the background is near.
Choose
by shape/
application
How to read
Model No
Applications
Earlier models
comparison Detecting a passing glass LCD transportation Mounting in handling arms
table

Mapping fiber FD-L12W


FD-L32H Seating
Fibers
confirmation fiber
Super FD-L11
Quality
FD-L30A
Threaded
Type
Square Head
Type
Cylindrical
Type
Alignment fiber
Sleeve
FD-L22A/L30A/L31A
Flat
Type LIST OF FIBERS
Small
Spot Reflective type
Narrow Fiber Sensing range (mm in) (Note 1, 2)
Beam
Bending cable FX-101
Wide Shape of fiber head U-LG Ambient
Type Model No. radius length (Upper value) Protection temp. Dimensions
Beam (mm) : FX-500 series LONG
(mm) FAST FX-102
Convergent
Reflective Free-cut H-SP (Lower value)
Type
Mapping STD
Retroreflective R4 0 to 87 0 to 3.425 16 to 30
Type 0 to 56 0 to 2.205 0 to 74 0 to 2.913 0.630 to 1.181 –40 to
FD-L32H Bending 1 to 38 0.039 to 1.496 0 to 50 P.63
4m HYPR +60 °C
Chemical / Oil- durability 0 to 110 0 to 4.331 Cannot use 0 to 1.969
resistant W25 × H7.3 × D30

Heat- Alignment 7RXJK STD 0 to 43 0 to 1.693 0 to 40


R2 0 to 43 0 to 1.693 0 to 43 0 to 1.693 0 to 1.575
resistant FD-L30A Bending HYPR 0 to 42 0 to 1.654 0 to 50
Vacuum- W20 × H29 × D3.8 durability 0 to 43 0 to 1.693 0 to 29 0 to 1.142 0 to 1.969
resistant
Alignment 7RXJK 3m STD 4 to 33 0.157 to 1.299 5 to 30
Liquid Leak / R4 4 to 33 0.157 to 1.299 4 to 33 0.157 to 1.299 0.197 to 1.181 0 to
Liquid Detection FD-L31A Bending 4 to 32 0.157 to 1.260 4 to 33
HYPR +70 °C
W23.5 × H29 × D4.5 durability 3 to 35 0.118 to 1.378 5 to 25 0.197 to 0.984 0.157 to 1.299
Alignment 7RXJK STD 0 to 28 0 to 1.102 0 to 19
Glass substrate detection

0 to 24 0 to 0.945 0 to 27 0 to 1.063 0 to 0.748


Fiber FD-L22A 0 to 24 0 to 0.945 0 to 25
Options 2m HYPR
W17 × H29 × D3.8 R2 0 to 31 0 to 1.220 0 to 18 0 to 0.709 0 to 0.984
Seating confirmation 7RXJK Bending STD 0 to 30 0 to 1.181 0 to 28
durability 0 to 29 0 to 1.142 0 to 30 0 to 1.181 0 to 1.102 –20 to
FD-L23 0 to 28 0 to 1.102 0 to 30
Semi-custom 3m HYPR +70 °C
W18 × H29 × D3.8 0 to 30 0 to 1.181 1.5 to 24 0.059 to 0.945 0 to 1.181
fibers IP40
Seating confirmation 7RXJK STD 0 to 10.5 0 to 0.413 0 to 8
0 to 9.5 0 to 0.374 0 to 10 0 to 0.394 0 to 0.315
FD-L11 0 to 9 0 to 0.354 0 to 9
HYPR
W12 × H19 × D3 R4 0 to 11.5 0 to 0.453 0 to 8 0 to 0.315 0 to 0.354
Fiber P.62
Dimensions Seating confirmation 7RXJK Bending STD 0 to 5.5 0 to 0.217 0 to 4.5
durability 0 to 5 0 to 0.197 0 to 5.5 0 to 0.217 0 to 0.177
Thru-beam FD-L10 0 to 4.5 0 to 0.177 0 to 5.5
Type HYPR
W12 × H19 × D3 0 to 6 0 to 0.236 0 to 4 0 to 0.157 0 to 0.217 –40 to
Retroreflective
Type 7RXJK STD 1 to 18 0.039 to 0.709 3 to 15 +60 °C
R2 1.5 to 16 0.059 to 0.630 1 to 18 0.039 to 0.709 0.118 to 0.591
Reflective FD-L21 Bending 2 to 15 0.079 to 0.591 1.5 to 16
Type 2m HYPR
W24 × H21 × D4 durability 1 to 19 0.039 to 0.748 3 to 12 0.118 to 0.472 0.059 to 0.630
Others STD 2 to 15 0.079 to 0.591 7 to 12
3 to 14 0.118 to 0.551 2 to 15 0.079 to 0.591 0.276 to 0.472
FD-L21W R1 HYPR 4 to 14 0.157 to 0.551 3 to 14
W24 × H21 × D4 1.5 to 15 0.059 to 0.591 6.5 to 10 0.256 to 0.394 0.118 to 0.551
7RXJK STD 35 1.378 5 to 15
purpose
General

Amplifiers R2 23 0.906 32 1.260 0.197 to 0.591 –40 to


FD-L20H Bending 2 to 15 0.079 to 0.591 1 to 30
HYPR +70 °C
FX-500 W6 × H18 × D14 durability 45 1.772 5 to 9 0.197 to 0.354 0.039 to 1.181
series
STD 12.5 0.492 1 to 4.5
FX-100 8 0.315 –40 to
Ultla-
small

12 0.472 0.039 to 0.177


series FD-L12W R1 1m HYPR 0.5 to 7 0.020 to 0.276 0.5 to 7 IP30 +60 °C
W7.2 × H7.5 × D2 14 0.551 0.5 to 4 0.020 to 0.157 0.020 to 0.276
Notes: 1) The sensing range is specified for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm
t0.079 in) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 × 100 mm 3.937 × 3.937 in).
INDEX 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
27

Retroreflective Type
New product
introduction
Tough
Fiber

Compared with the thru-beam type, it is easier to


arrange the fibers since one side is a reflector. Sensing Fiber
Selection
Guide
transparent objects is also its advantage.
Model
Choose
by shape/
Applications application
How to read
Model No.
Detecting transparent film Detecting transparent seals on Earlier models
transparent sheet comparison
table
FR-KZ50E

FR-Z50HW
Fibers
Super
Quality
Threaded
Reflector Type
RF-003 Square Head
(Accessory for Type
FR-KZ50E) Cylindrical
Type

Sleeve
LIST OF FIBERS Flat
Type
Retroreflective type Small
Sensing range (mm in) (Note 1, 2) Spot
Fiber
Bending cable FX-101 Narrow
Shape of fiber head U-LG Ambient Beam
Type Model No. radius length (Upper value) Protection Dimensions
(mm) : FX-500 series LONG temp. Wide
(mm) FAST FX-102
Free-cut Beam
H-SP (Lower value)
Convergent
STD 100 to 1,400 3.937 to 55.118 100 to 550 Reflective
polarizing

W5.2 × H9.5 × D16 Type


100 to 990 3.937 to 38.976 100 to 1,200 3.937 to 47.244 3.937 to 21.654 IP40 –25 to
filters
With

FR-Z50HW R1 HYPR 100 to 780 3.937 to 30.709 100 to 830 +55 °C Retroreflective
W30 × H30 × D0.5 100 to 1,900 3.937 to 74.803 100 to 490 3.937 to 19.291 3.937 to 32.677 Type
W7.5 × H2.2 × D11.2 Chemical / Oil-
Ultra-narrow

resistant
7RXJK STD 15 to 460 0.591 to 18.110 15 to 200 Heat-
beam

15 to 310 0.591 to 12.205 15 to 410 0.591 to 16.142 0.591 to 7.874 resistant


FR-KZ22E 15 to 220 0.591 to 8.661 15 to 360
HYPR
15 to 570 0.591 to 22.441 15 to 100 0.591 to 3.937 0.591 to 14.173 Vacuum-
P.55 resistant
W4 × H2 × D21.5 2m
R2 –40 to Liquid Leak /
7RXJK IP30 Liquid Detection
Side sensing Top sensing

W5.2 × H9.5 × D21 Bending +60 °C


Narrow beam

FR-KZ50H durability
STD 20 to 800 0.787 to 31.496 20 to 200
W10.6 × H28 × D10.1 20 to 300 0.787 to 11.811 20 to 400 0.787 to 15.748 0.787 to 7.874
W9.5 × H25 × D5.2
7RXJK HYPR 20 to 200 0.787 to 7.874 20 to 350 Fiber
20 to 1,000 0.787 to 39.370 20 to 200 0.787 to 7.874 0.787 to 13.780 Options
FR-KZ50E
W28 × H10.6 × D10.1

Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. Semi-custom
fibers
Sensing range when FR-Z50HW is used in combination with a reflector (optional)
Sensing range (mm in) Fiber
Reflector Dimensions
FX-500 series
model No. FX-101 FX-102 Thru-beam
HYPR U-LG LONG STD FAST H-SP Type
100 to 19,000 100 to 8,000 100 to 5,000 100 to 3,600 100 to 2,900 100 to 1,400 100 to 2,400 100 to 5,000
RF-230 3.937 to 748.030 3.937 to 314.960 3.937 to 196.850 3.937 to 141.732 3.937 to 114.173 3.937 to 55.118 3.937 to 94.488 3.937 to 196.850
Retroreflective
Type
100 to 8,000 100 to 4,700 100 to 3,500 100 to 3,000 100 to 1,800 100 to 830 100 to 1,300 100 to 2,600
RF-220 3.937 to 314.960 3.937 to 185.039 3.937 to 137.795 3.937 to 118.110 3.937 to 70.866 3.937 to 32.677 3.937 to 51.181 3.937 to 102.362
Reflective
Type
100 to 5,500 100 to 2,700 100 to 2,400 100 to 1,500 100 to 1,200 100 to 530 100 to 980 100 to 1,300
RF-210 3.937 to 216.535 3.937 to 106.299 3.937 to 94.488 3.937 to 59.055 3.937 to 47.244 3.937 to 20.866 3.937 to 38.583 3.937 to 51.181 Others

Note: The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than 100 mm 3.937 in.
However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs,
adjust the threshold value of the amplifier unit before use.
Amplifiers
FIBER OPTION FX-500
series
Reflectors (for FR-Z50HW) P.45

FX-100
series

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
28

Chemical / Oil-resistant
New product
introduction
Tough
Fiber

With the case and fiber sheath made of PFA, the fiber can be used
Fiber
Selection with various types of chemical liquids.
Guide
The fiber core will not harden or break, even in environments where
Model
oil is present.
Choose
by shape/
application
How to read
Model No
Full-protection type FT-R60Y (Square head type M6 / thru-beam type)
Earlier models
comparison High environmental Less susceptibility to oil Resistant to oil and coolant
table
resistance adhesion thanks to fluorine The fiber head and fiber cable are connected by
The head, nut, and washer resin the “fastening and caulking” method without using
are made from rust-resistant Fibers deliver stable detection, adhesives. This method eliminates concerns that
Fibers
SUS304. The unbreakable since the sensing part is sealed adhesives will absorb moisture in high-humidity
Super tough fiber with high durability is with fluorine resin, which environments and
Quality
covered in a fluorine resin tube. does not allow oil penetration. damage the fiber. The
Threaded
Type The fiber head is also covered Additionally, the detection part enclosure achieves
Square Head with a fluorine resin component, features a convex design made IP68G protection,
Type
achieving a high level of of fluorine resin, achieving lower so the fiber can be
Cylindrical
Type environmental resistance. friction than glass. installed around metal
Sleeve
processing machines
shrouded in the oil mist.
Flat
Type M6 Test oil Product
Small Lubricating oil Velocite Oil No. 3
Spot
Yushiron Cut Abas KZ201
Narrow Non-water-soluble cutting oil
Yushiron Cut UH75
Beam
Stainless Syntilo 9954 (10% diluted)
Wide Water-soluble cutting oil
Beam steel Yushiroken S50N (2% diluted)
Fluorine resin (SUS304) Less susceptible to oil
Convergent Alcohol-based neutral detergent Super Teepol
Reflective (PFA) adhesion than glass
Type *Yushiron and Yushiroken are registered trademarks of Yushiro
Retroreflective Chemical Industry Co., Ltd.
Type
Chemical / Oil-
resistant
Heat-
resistant Cable-protection type FT-R44Y / FD-R61Y
Vacuum-
resistant FT-R44Y (Square head type M4 / thru-beam type) FD-R61Y (Square head type M6 / reflective type)
Liquid Leak /
Liquid Detection Compatible with
optional lens
Stainless Stainless
steel steel
(SUS304) (SUS304)
Fiber M6
Options

M4 Fluorine resin Fluorine resin


Semi-custom
fibers (PFA) (PFA)

Fiber
Dimensions Full-protection type FD-S60Y (Cylindrical type / reflective type) Metal-free
Thru-beam
Type Metal-free design Detection in long range and narrow Improved tip flexibility
Retroreflective Since no metal components are used, view The protective tube features a bending radius
Type
there is no need to worry about metal A built-in lens achieves narrow-view of R30 mm R1.181 in, which improved the
Reflective
Type contamination, even if the protective detection with an aperture angle of 30 cable arrangement compared to previous
Others tube is damaged. It is ideal for use in degrees. (R40 mm R1.575 in) designs.
applications such as semiconductor
front-end equipment where a clean
environment is required.
Amplifiers
FX-500
series Metal-free design
R30 mm
FX-100
R1.181 in
series ø4 mm ø0.157 in

ø5.5 mm ø0.217 in
INDEX
29

LIST OF FIBERS New product


introduction
Thru-beam type (one pair set) Tough
Sensing range (mm in) (Note 1) Fiber
Fiber Beam
Bending cable FX-101
Shape of fiber head U-LG axis Ambient
Type Model No. radius length (Upper value) dia. Protection temp. Dimensions
(mm) : FX-500 series LONG
(mm) FAST FX-102 Fiber
Free-cut (mm) Selection
H-SP (Lower value) Guide
Cable-protection type
7RXJK STD 1,600 62.992
Square head type

Compatible with lens Model


720 28.346 1,100 43.307 210 8.268 IP67 –55 to
Oil-resistant

ø1
M4

FT-R44Y 430 16.929 640 25.197


HYPR (Note 4) +80 °C
W7×H9.5×D15.5 R4 3,000 118.110 130 5.118 Choose
by shape/
Bending P.52 application
Full-protection type 7RXJK 2m STD 3,600 141.732(Note 2)
durability 2,100 82.677 3,600 141.732(Note 2) 690 27.165 –55 to How to read
M6

FT-R60Y 1,260 49.606 1,890 74.409 ø3.5 Model No.


HYPR +80 °C
W10×H11×D21.2 (Note 2) 3,600 141.732 400 15.748 Earlier models
comparison
Easy mounting • Rectangular head 7RXJK table
SEMI S2 compliant
STD
Flat type

W7 × H15 × D13
R4 3,600 141.732(Note 2)
Metal-free 3,100 122.047 3,600 141.732(Note 2) 520 20.472 0 to
FT-Z802Y Bending 1,900 74.803 3,100 122.047 P.54
2m HYPR +60 °C
durability (Note 2) 3,600 141.732 470 18.504 Fibers
Super
Heat-resistant 115 °C Quality
Chemical-resistant

Metal-free STD 3,600 141.732(Note 2)


ø5.5
(Note 2) 3,600 141.732 3,600 141.732(Note 2) 990 38.976 ø3.7 IP68G –40 to P.50 Threaded
FT-HL80Y 2,300 90.551 2,340 92.126 Type
HYPR +115 °C
(25) (Note 2) 3,600 141.732 740 29.134 Square Head
Type
Cylindrical type

Metal-free
Cylindrical
STD 3,600 141.732(Note 2) Type
ø5.5 (Note 2) 3,600 141.732 3,600 141.732(Note 2) 1,100 43.307
FT-L80Y R30 2m 2,800 110.236 2,600 102.362 P.51
HYPR Sleeve
(25) (Note 3) (Note 2) 3,600 141.732 920 36.220
–40 to Flat
Side-view STD +70 °C Type
Metal-free 2,800 110.236
1,300 51.181 Small
ø5.5 2,200 86.614 340 13.386
FT-V80Y HYPR 800 31.496 800 31.496 ø2.8 P.53 Spot
(25) (Note 2) 3,600 141.732 240 9.449 Narrow
Beam
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Wide
2) The fiber cable length practically limits the sensing range. Beam
3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted. Convergent
Reflective
4) The fiber part is oil-resistant. Type
Retroreflective
Reflective type Type

Fiber Sensing range (mm in) (Note 1, 2) Chemical / Oil-


Beam resistant
Bending cable FX-101
Shape of fiber head U-LG axis Ambient Heat-
Type Model No. radius length (Upper value) Protection Dimensions
(mm) : FX-500 series LONG dia. temp. resistant
(mm) FAST FX-102
Free-cut (mm) Vacuum-
H-SP (Lower value) resistant
Cable-protection type 7RXJK
Chemical-resistant Oil-resistant
Square head type

R4 STD 610 24.016 Liquid Leak /


280 11.024 435 17.126 85 3.346 IP67 –55 to Liquid Detection
FD-R61Y — P.63
M6

Bending 2m HYPR 160 6.299 185 7.283 (Note 3) +80 °C


W10×H11×D15.5 durability 50 1.969
990 38.976
Metal-free 7RXJK Protective tube
Cylindrical type

R30 mm Fiber STD 590 23.228


ø5.5
–40 to Fiber
FD-S60Y R4 2m
320 12.598 420 16.535 140 5.512
— IP68G P.64 Options
200 7.874 300 11.811 +70 °C
16 Bending (Note 4) HYPR 75 2.953
600 23.622
durability
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut.
2) The sensing range is specified for white, non-glossy paper. Semi-custom
3) The fiber part is oil-resistant. fibers
4) The allowable cutting range is 500 mm 19.685 in from the end that is inserted to the amplifier.

Applications Fiber
Detecting wafer cassette in cleaning tank Sensing a wafer in corrosive environment Dimensions
Thru-beam
Cleaning tank Type
Retroreflective
Wafer Type
cassette FT-Z802Y FT-HL80Y
Reflective
FT-L80Y Type

Others

Wafer

Detecting a container at a chemical Piller Amplifiers


FX-500
series
FX-100
FT-Z802Y series

INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
30

Heat-resistant
New product
introduction
Tough
Fiber

It can be used under environments of -60 to +350 °C


Fiber
Selection -76 to +662 °F.
Guide
A joint type for wider workability is also available.
Model
Choose
by shape/
application
How to read
Model No Applications
Earlier models
comparison
table IC detection within a high Detecting glass substrates
temperature handler
FT-H20W-M1
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type

Sleeve

Flat
Type
Small
Spot LIST OF FIBERS
Narrow
Beam Thru-beam type (one pair set)
Wide Sensing range (mm in) (Note 1)
Beam Beam
Heat- Bending Fiber cable FX-101 axis
Convergent Shape of fiber head U-LG Ambient
Reflective Type resistant Model No. radius length (Upper value) dia. Dimensions
Type (mm) FX-500 series LONG temp.
temp. (mm) : Free-cut FAST FX-102
Retroreflective (mm)
Type H-SP (Lower value)
Lens mountable
Chemical / Oil-
(FX-LE1/LE2/SV1)
resistant M4 FT-H35-M2 R25
Heat- 30
STD 880 34.646
resistant 430 16.929 670 26.378 170 6.693 –60 to
350 °C Sleeve
Sleeve 60
60 mm
mm Fiber 2m 250 9.843 490 19.291 ø1.2
Vacuum- HYPR +350 °C
M4 R25 1,200 47.244 80 3.150
resistant FT-H35-M2S6
ø2.1 27 Sleeve
Liquid Leak /
Liquid Detection R10
Heat-resistant

P.50
Allows flexible wiring
Lens mountable STD 1,000 39.370
470 18.504 840 33.071 100 3.937
(FX-LE1/LE2/SV1)
M4 FT-H20W-M1 R10 HYPR 300 11.811 300 11.811
ø0.8
Fiber (Note 2) 1,600 62.992 90 3.543 –60 to
Options 200 °C 23 1m
+200 °C
Lens mountable STD 1,300 51.181
(FX-LE1/LE2/SV1) M4 540 21.260 960 37.795 210 8.268
FT-H20-M1 330 12.992 540 21.260
ø1.2
HYPR
Semi-custom 23 (Note 2) 1,600 62.992 110 4.331
R25
fibers Lens mountable (FX-LE2 only) STD 1,900 74.803
M4 700 27.559 1,300 51.181 250 9.843 –60 to
130 °C FT-H13-FM2 410 16.142 700 27.559
ø1.5 P.49
2m HYPR +130 °C
16 3,300 129.921 140 5.512
Fiber Lens mountable
Dimensions (FX-LE1/LE2/SV1) FT-H20-J20-S
200 mm
Thru-beam (Note 5)
(Note 3)
Type
STD 1,000 39.370
Retroreflective M4 470 18.504
Type FT-H20-J30-S 790 31.102 135 5.315
300 mm
Heat-resistant (joint)

(Note 5) HYPR 300 11.811 420 16.535


Reflective 23 (Note 3) 1,600 62.992 90 3.543
Type Heat-
resistant
Others FT-H20-J50-S –60 to
200 °C side ø1.2 P.50
(Note 5) +200 °C
R18
(Note 4) 500 mm
Side-view
FT-H20-VJ50-S (Note 3)
Amplifiers ø3.8 (Note 5) STD 1,300 51.181
600 23.622 980 38.583 150 5.906
24
FX-500 ø4 HYPR 390 15.354 500 19.685
series FT-H20-VJ80-S 2,100 82.677 120 4.724
800 mm
FX-100 (Note 5)
(Note 3)
series
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut).
4) Bending durable fiber R4 mm R0.157 in or more for ordinary temperature side.
INDEX
5) Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set.
31

Heat-resistant joint fiber set contents New product


introduction
Tough
Heat-resistant side (–60 to +200 °C –76 to +392 °F) Ordinary temperature side Fiber
Ordinary temperature 100 mm 3.937 in Amplifiers
(–40 to +70 °C –40 to +158 °F) approx.
Fiber
Selection
Guide

Model
Choose
Heat-resistant Ordinary temperature side fiber [FT-42 by shape/
application
side fiber Nut (resin) (Fiber cable length 2m, Free-cut)]
How to read
Nut (metal), Use when securing to a mounting bracket. Model No.
Earlier models
comparison
table
Model No. when ordering individually as spare parts
• Heat-resistant side fiber one pair set
FT-H20-J20, FT-H20-J30, FT-H20-J50, FT-H20-VJ50, FT-H20-VJ80 Fibers
Super
• Ordinary temperature side fiber one pair set Quality
FT-42 Threaded
Type
Square Head
LIST OF FIBERS Type
Cylindrical
Type
Reflective type
Sensing range (mm in) (Note 1, 2) Sleeve
Heat- Bending Fiber cable FX-101 Ambient Flat
Shape of fiber head U-LG
Type resistant Model No. radius length (Upper value) temp. Dimensions Type
(mm) FX-500 series LONG
temp. (mm) : Free-cut FX-102
FAST Small
H-SP (Lower value) Spot
Coaxial Narrow
M6 Beam
FD-H35-M2 R25
Wide
25 STD 540 21.260 Beam
260 10.236 460 18.110 75 2.953
Sleeve 60 mm 2m 150 5.906 280 11.024 Convergent
HYPR Reflective
M6 ø2.8 720 28.346 45 1.772 Type
FD-H35-M2S6 –60 to
350 °C Fiber P.61 Retroreflective
22 +350 °C Type
R25
Sleeve 90 mm Sleeve Chemical / Oil-
STD 550 21.654 resistant
M4 R10 260 10.236 440 17.323 85 3.346 Heat-
FD-H35-20S
Threaded

ø2.1 HYPR 140 5.512 200 7.874 resistant


27 840 33.071 45 1.772
Vacuum-
Coaxial resistant
STD 550 21.654
M6 1m 330 12.992 500 19.685 120 4.724 Liquid Leak /
FD-H20-M1 200 7.874 300 11.811 Liquid Detection
HYPR
28 840 33.071 55 2.165 –60 to
200 °C
+200 °C
Heat-resistant

Coaxial STD 500 19.685


M4 230 9.055 380 14.961 90 3.543
FD-H20-21 130 5.118 280 11.024
P.60 Fiber
HYPR
27 770 30.315 45 1.772 Options
STD 640 25.197
M6 350 13.780 600 23.622 100 3.937 –60 to
130 °C FD-H13-FM2 200 7.874 280 11.024 +130 °C
2m HYPR
21 880 34.646 65 2.559 Semi-custom
fibers
STD 30 1.181 2 to 9
Glass substrate detection convergent reflective

17 0.669 25 0.984 0.079 to 0.354 –60 to


300 °C FD-H30-L32 R25 2m
12 0.472 0 to 17 +300 °C P.61
HYPR
W19 × H27 × D5 40 1.575 1.5 to 6 0.059 to 0.236 0 to 0.669
Fiber
STD 1 to 30 0.039 to 1.181 4 to 16 Dimensions
1.5 to 26 0.059 to 1.024 1 to 28 0.039 to 1.102 0.157 to 0.630 –20 to
FD-H25-L43 1.5 to 24 0.059 to 0.945 4 to 23 +250 °C Thru-beam
W21 × H33.2 × D5
HYPR Type
1 to 31 0.039 to 1.220 2 to 18 0.079 to 0.709 0.157 to 0.906 Ordinary
250 °C 3m Retroreflective
STD 4 to 43 0.157 to 1.693 7 to 35 temp. side: Type
5 to 42 0.197 to 1.654 4.5 to 43 0.177 to 1.693 0.276 to 1.378 –20 to
FD-H25-L45 5 to 40 0.197 to 1.575 7 to 38 +70 °C
P.60 Reflective
W21 × H34.5 × D5
HYPR
4 to 43.5 0.157 to 1.713 6.5 to 34 0.256 to 1.339 0.276 to 1.496 Type
STD 32 1.260 0 to 10 Others
16 0.630 24 0.945 0 to 0.394 –60 to
180 °C FD-H18-L31 13 0.512 0 to 25 +180 °C
2m HYPR
W19 × H27 × D5 60 2.362 2 to 6.5 0.079 to 0.256 0 to 0.984
Notes: 1) The sensing range of reflective type is the value for white non-glossy paper (50 × 50 mm 1.969 × 1.969 in glass substrate for FD-H30-L32,
FD-H18-L31, transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in for FD-H25-L43 and FD-H25-L45). Amplifiers
2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
FX-500
series

FIBER OPTION FX-100


series

Lens (For thru-beam type fiber) P.42


INDEX
32

Vacuum-resistant
New product
introduction
Tough
Fiber

Usable in high-temperatures of 300 °C 572 °F vacuum


Fiber
The leakage of FV-BR1 is still less than a very slight FT-H30-M1V-S
Selection
Guide
1.33 × 10–10 Pa · m3/s [He], so that it can be used in FD-H30-KZ1V-S
Model
vacuums with confidence.
Choose
by shape/ FD-H30-L32V-S
application
How to read
Model No Applications
Earlier models
comparison
table
Detecting an FPD in vacuum chamber Highly resistant to repeated bending
Vacuum resistant
Vacuum resistant convergent long range reflective fiber Because it has a bending durability of over 100,000
reflective fiber
FD-H30-L32V-S
FD-H30-KZ1V-S times (R20 mm R0.787 in), it is highly resistant to
Fibers
Vacuum resistant
expansion lens
repeated bending and is optimal for mounting on
Super
Quality FV-LE1 moving robot hand.
Threaded Vacuum resistant
Type
thru-beam fiber
Square Head FT-H30-M1V-S
Type
Cylindrical
Type

Sleeve

Flat
Type
Vacuum resistant
Small thru-beam fiber
Spot FT-H30-M1V-S
Narrow
Beam Vacuum resistant side-view lens
FV-SV2
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
LIST OF FIBERS
resistant
Thru-beam type (one pair set)
Vacuum-
resistant Sensing range (mm in)
Liquid Leak / Bending Fiber FX-101 Beam
Shape of fiber head U-LG Ambient
Liquid Detection Type Model No. radius cable (Upper value) axis dia. Dimensions
(mm) length FX-500 series LONG temp.
(mm) FAST FX-102 (mm)
H-SP (Lower value)
300 °C
Thru-beam
Vacuum-

STD 590 23.228


resistant

Fiber Lens mountable (FV-LE1/SV2) M4


Options FT-H30-M1V-S 270 10.630 470 18.504 110 4.331 –30 to
R18 1m 160 6.299 280 11.024 ø1.2 P.50
(Note) HYPR +300 °C
30 1,000 39.370 55 2.165

Note: Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
Semi-custom
fibers

Reflective type
Sensing range (mm in)(Note 2)
Fiber
Dimensions Bending Fiber FX-101
Shape of fiber head U-LG Ambient
Type Model No. radius cable (Upper value) temp. Dimensions
Thru-beam (mm) length FX-500 series LONG
Type (mm) FAST FX-102
Retroreflective H-SP (Lower value)
Type 300 °C, Rectangular head
Reflective

STD 10 to 340 0.394 to 13.386 25 to 80


Vacuum-resistant

Reflective FD-H30-KZ1V-S 20 to 200 0.787 to 7.874 15 to 270 0.591 to 10.630 0.984 to 3.150
1m 20 to 120 0.787 to 4.724 10 to 220
Type
W9.5 × H5.2 × D15
(Note 1) HYPR
5 to 500 0.197 to 19.685 20 to 45 0.787 to 1.772 0.394 to 8.661
–30 to
Others R18 P.61
2.5 to 6.5 +300 °C
300 °C, Glass substrate detection
Convergent

STD 12 0.472
reflective

FD-H30-L32V-S 8 0.315 10 0.394 0.098 to 0.256


3m
(Note 1) HYPR 5.5 0.217 0 to 11
W19 × H5 × D27 18 0.709 1.5 to 3 0.059 to 0.118 0 to 0.433
Amplifiers
Notes: 1) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
FX-500 2) The sensing range of reflective type is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in.
series
FX-100
series

INDEX
33

New product
introduction
Tough
Fiber

Fiber
Selection
Guide

Model
Choose
by shape/
application
How to read
Vacuum-resistant fiber set contents Model No.
Earlier models
comparison
Vacuum side Atmospheric side Digital fiber sensor table

Fibers
Super
Vacuum Quality
resistant fibers Atmospheric side fiber (FT-J8)
Chamber wall or flange Threaded
Type
Photo-terminals (FV-BR1) Square Head
(Recommended thickness: 3.0 to 20 mm 0.118 to 0.787 in) Type
Cylindrical
Type
Model No. when ordering individually as spare parts Sleeve

Vacuum resistant fiber ●
Photo-terminal ●
 ounting bracket for FD-H30-KZ1V(-S)
M Flat
FT-H30-M1V (one pair set) FV-BR1 (one pair set) MS-FD-2 Type
FD-H30-KZ1V ●
Atmospheric side fiber Small
Spot
FD-H30-L32V FT-J8 (one pair set)
Narrow
Beam
Wide
Beam
Convergent
FIBER OPTIONS Reflective
Type
Retroreflective
Lens (For thru-beam fiber) Type
Chemical / Oil-
resistant
Designation Model No. Description Heat-
resistant
Increases the sensing range 4 times or more. Vacuum-
• Ambient temperature: –60 to +350 °C –76 to +662 °F (Note 3) resistant
• Beam axis dia: ø3.6 mm ø0.142 in Liquid Leak /
Sensing range (mm in) [Lens on both sides] (Note 4) Liquid Detection
Vacuum
resistant Amplifier FX-500 series FX-100 series
FV-LE1
expansion lens
For thru-beam type fiber

(Note 1) Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
Fiber
3,600 3,600 3,400 1,500 900 370 450 1,600 Options
FT-H30-M1V-S 141.732 141.732 133.858 59.055 35.433 14.567 17.717 62.992
(Note 2) (Note 2)

Beam axis is bent by 90°.


• Ambient temperature: –60 to +300 °C –76 to +572 °F (Note 3) Semi-custom
fibers
• Beam axis dia: ø3.7 mm ø0.146 in
Vacuum Sensing range (mm in) [Lens on both sides] (Note 4)
resistant Amplifier FX-500 series FX-100 series
FV-SV2
side-view lens Fiber
(Note 1) Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 Dimensions
3,600 3,600 3,400 1,500 900 370 450 1,600 Thru-beam
FT-H30-M1V-S 141.732 141.732 133.858 59.055 35.433 14.567 17.717 62.992 Type
(Note 2) (Note 2)
Retroreflective
Type
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the lens, as the beam envelope becomes narrow and alignment is difficult.
2) The fiber cable length practically limits the sensing range. Reflective
Type
3) Refer to previous page for the ambient temperature of fibers to be used in combination.
4) The fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series, in FX-102 take into  Others
account the length of the FT-J8 atmospheric side fiber.

Amplifiers
FX-500
series
FX-100
series

INDEX
34

Liquid Leak / Liquid Detection


New product
introduction
Tough
Fiber

It corresponds to various liquid events, from the contact (wetted) type to the pipe
Fiber
Selection mounting type, and up to leak detection.
Guide

Model
Choose
by shape/
application
How to read
Model No For detecting the upper limit of liquid For detecting the lower limit of liquid
Earlier models
comparison surface level, sensor that receives beam surface level, sensor that receives beam
table
when “liquid is absent” is recommended. when “liquid is present” is recommended.
The sensor will turn OFF during abnormal conditions The sensor will turn OFF during abnormal conditions (insuf-
Fibers (excess fluid, fiber disconnection, etc.)! ficient liquid, fiber disconnection, etc.) !
Liquid absent: Beam received (Output ON) Liquid present: Beam received (Output ON)
Super
Quality Liquid present / fiber is cutoff: Beam not received (Output OFF) Liquid absent / fiber is cutoff: Beam not receired (Output OFF)
Threaded
Type
FD-FA93 Strong against air bubbles FT-F93 Thru-beam
Square Head
Type Applicable pipe: Transparent pipe, Outer diameter ø8 mm
Cylindrical ø0.315 in or more
Type (When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in)

Sleeve
FD-F41
Flat FD-F41 FT-F93
Type Standard type
FD-F4
Small
Spot
Narrow
FD-F4
Beam
For 1 mm 0.039 in thick pipes
Wide manufactured by PFA
Beam
Convergent
Reflective
Type
Retroreflective
Type Full-protection type FD-HF40Y / FD-F41Y (Liquid level sensing) Metal-free
Chemical / Oil-
resistant FD-HF40Y FD-F41Y
Heat-
resistant Small R10 mm R0.394 in R10 mm R0.394 in
Vacuum- diameter Sheath: Polyethylene Primary sheath: Polyethylene
resistant Secondary sheath: Fluorine resin
Liquid Leak /
type 2,000 mm 2,000 mm
Liquid Detection (ø4 mm ø0.157 in) 78.740 in 78.740 in
Bends easily with
its small bending
radius, protective R20 mm R0.787 in R20 mm R0.787 in
Fiber tube is cuttable ø4 mm ø0.157 in protective ø4 mm ø0.157 in protective
Options and extendable tube (fluorine resin) tube (fluorine resin)

500 mm 500 mm
Semi-custom 19.685 in 19.685 in
fibers (Cuttable*) (Cuttable*)
Heat-resistant Heat-resistant
+105 °C +221 °F +70 °C +158 °F
Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type * The range of 50 mm 1.969 in from the fiber tip cannot be cut. Also, fiber length can be extended using MS-FX-02Y (optional).
Reflective
Type

FD-F71 (Liquid level sensing) SEMI S2 compliant


Others
Full-protection type
Detect chemical leaks in semiconductor and LCD manufacturing processes.
Amplifiers Compact, space-saving
FX-500 Side-mountable fiber head as slim as 10 mm 0.394 in is good to use in
series
FX-100
confined spaces.
series
Ideal for use with chemicals and volatile materials
This fiber type sensor is safer to use with volatile materials (SEMI S2
compliant). The fluorine resin fiber head makes it ideal for use with
INDEX
chemicals.
35

LIST OF FIBERS New product


introduction
Reflective type / Thru-beam type
Tough
Description Fiber
Bending Fiber cable
Shape of fiber head Ambient
Type Model No. radius length FX-500 series FX-101 Protection Dimensions
(mm) temp.
(mm) : Free-cut (STD mode) FX-102
Fiber
Heat resistant 125 °C Protective tube ø6 mm ø0.236 in Selection
Fluorine resin coating –40 to Guide
R40 Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable)
ø6 FD-F8Y 2m IP68 P.59
Fiber Liquid surface not contacted: Beam received, +125 °C Model
Liquid level sensing

R15 (Note 1) Liquid surface contacted: Beam not received


Choose
Heat resistant 105 °C ø4 mm ø0.157 in by shape/
Fluorine resin coating application
Metal-free FD-HF40Y Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) –40 to
P.61 How to read
Contact type

ø4 (Note 2) Protective tube Liquid surface not contacted: Beam received, +105 °C Model No.
R20 Liquid surface contacted: Beam not received Earlier models
Fiber IP68G comparison
Heat resistant 70 °C 2m ø4 mm ø0.157 in table
Fluorine resin coating throughout the fiber
Metal-free FD-F41Y R10 Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) –40 to
ø4 (Note 2) Liquid surface not contacted: Beam received, +70 °C
Liquid surface contacted: Beam not received
SEMI S2 compliant 7RXJK Fibers
leak

W20 × H30 × D10 Liquid leak detection


detection

FD-F71
R4 Leak absent: Beam received, Leak present: Beam interrupted IP67
–20 to Super
Liquid level sensing Liquid

Bending durability 5m Compatible amplifire: FX500 series only


+60 °C Quality
Threaded
Standard Type
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in
W25 × H13 × D20 transparent pipe [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, P.59 Square Head
FD-F41 Type
glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
Liquid absent: Beam received, Liquid present: Beam not received –40 to Cylindrical
For 1 mm thick PFA pipe
R10 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to

+100 °C Type
Pipe-mountable type

ø1.024 in transparent pipe [PFA (fluorine resin) or equivalently Sleeve


W25 × H13 × D20 FD-F4
transparent pipe, wall thickness 1 mm 0.039 in]
Liquid absent: Beam received, Liquid present: Beam not received Flat
Mountable on pipe·array fiber 7RXJK Type
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more
2m
W6.5 × H28.3 × D17 FD-FA93 R4 transparent pipe (When used with the tying bands: ø8 to ø80 mm –40 to Small
Liquid sensing

ø0.315 to ø3.150 in) [PFA (fluorine resin), including translucent] Spot


Bending durability +70 °C
Liquid absent: Beam received, Liquid present: Beam not received Narrow
Beam
SEMI S2 compliant 7RXJK Protective tube R20 Applicable pipe diameter: Outer dia. ø3 to ø10 mm ø0.118 to IP40
Fiber ø0.394 in transparent pipe [PFA (fluorine resin) or equivalently Wide
–40 to Beam
FT-F93 transparent pipe, wall thickness 0.3 to 1 mm 0.012 to 0.039 in] P.49
R2 Liquid absent: Beam not received, Liquid present: Beam received
+60 °C Convergent
W23 × H20 × D17 Reflective
Bending durability Compatible amplifire: FX500 series only Type
Notes: 1) The allowable cutting range is 1,000 mm 39.370 in from the end that the amplifier inserted. Retroreflective
2) Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint is available. Type
Chemical / Oil-
Accessories for additional supply resistant

MS-FD-F7-1 ●
MS-FD-F7-2 Heat-
resistant
(SUS mounting bracket for FD-F71) (PVC mounting bracket for FD-F71)
Vacuum-
resistant
FIBER OPTIONS Liquid Leak /
Liquid Detection

Designation Model No. Description


Liquid inflow This joint suppresses false operations due to Fiber
prevention joint MS-FX-01Y Options
(Note) liquid slip-in from the top of the protective tube.
Applicable fibers

Protective tube
FD-HF40Y
extension joint MS-FX-02Y The protective tube can be extended.
FD-F41Y Semi-custom
(Note)
fibers
Fiber mounting
joint MS-FX-03Y The joint is used for mounting fibers on a tank.
(Note)
Note: The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage. Fiber
Dimensions
Liquid inflow prevention joint
MS-FX-01Y Protective tube extension joint
MS-FX-02Y Fiber mounting
MS-FX-03Y joint Thru-beam
Type
MS-FX-01Y
• MS-FX-01Y MS-FX-02Y
• MS-FX-02Y MS-FX-03Y
• MS-FX-03Y
MS-FX-01Y MS-FX-02Y MS-FX-03Y Retroreflective
Union nut
Type
Body Union nut
Ferrule (MS-FX-YF)
Body Union nut
Ferrule (MS-FX-YF) Reflective
Union
Ferrule nut
(MS-FX-YF) Type
Body Union nut Union nut
Ferrule
Union nut(MS-FX-YF) Ferrule (MS-FX-YF)
Ferrule (MS-FX-YF) Ferrule (MS-FX-YF) Ferrule (MS-FX-YF)
Body
Union nut Ferrule (MS-FX-YF) Others
Union nut Body Body
Body
Ferrule (MS-FX-YF)
Body
Ferrule Body
Union nut(MS-FX-YF)
Ferrule (MS-FX-YF)
Union nut
Applications Union nut Amplifiers

Detecting liquid level in a tank Leak detection for use in semiconductor FX-500
series
device manufacturing FX-100
series

FD-F71
INDEX

7RXJK : Refers
‌ to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°) and more flexible (bending radius:
R4 mm R0.157 in or less) features.
36
Fibers are listed in alphabetic order.
New product SENSING RANGE Refer to p. 2~ for details of each fiber.
introduction
Tough Thru-beam type (one pair set)
Fiber

Sensing range (mm in) (Note 1)

Fiber
Selection Model No. FX-500 series FX-100 series Dimensions
Guide

Model HYPR U-LG LONG STD FAST H-SP FX-101 FX-102


Choose 19,600 19,600 19,600 19,600 16,000 6,300 14,000 19,600
by shape/ FT-140 P.48
application 771.652 (Note 2) 771.652 (Note 2) 771.652 (Note 2) 771.652 (Note 2) 629.920 248.031 551.180 771.652 (Note 2)
1,350 810 650 400 210 75 135 400
How to read FT-30 P.48
Model No 53.150 31.890 25.591 15.748 8.268 2.953 5.315 15.748
1,350 770 550 315 210 70 130 340
Earlier models FT-31 P.48
comparison 53.150 30.315 21.654 12.402 8.268 2.756 5.118 13.386
table 1,220 740 550 315 195 63 130 340
FT-31S P.48
48.031 29.134 21.654 12.402 7.677 2.480 5.118 13.386
990 590 440 260 150 53 80 240
FT-31W P.48
38.976 23.228 17.323 10.236 5.906 2.087 3.150 9.449
3,600 2,200 1,700 1,200 530 190 320 870
Fibers FT-40 P.48
141.732 (Note 2) 86.614 66.929 47.244 20.866 7.480 12.598 34.252
3,600 2,050 1,600 1,130 530 190 300 800
Super FT-42 P.48
Quality 141.732 (Note 2) 80.709 62.992 44.488 20.866 7.480 11.811 31.496
3,600 2,050 1,600 1,130 530 190 300 800
Threaded FT-42S P.48
141.732 (Note 2) 80.709 62.992 44.488 20.866 7.480 11.811 31.496
Type 3,300 1,900 1,400 800 490 160 260 720
FT-42W P.48
Square Head 129.921 74.803 55.118 31.496 19.291 6.299 10.236 28.346
Type 3,600 2,800 2,100 1,400 770 240 350 970
FT-43 P.48
Cylindrical 141.732 (Note 2) 110.236 82.677 55.118 30.315 9.449 13.780 38.189
Type 1,600 1,600 1,600 1,200 630 200 340 920
FT-45X P.49
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 47.244 24.803 7.874 13.386 36.220
Sleeve 3,600 3,600 3,600 3,600 3,600 1,100 1,900 3,600
FT-A11 P.49
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 43.307 74.803 141.732 (Note 2)
Flat 3,600 3,600 3,600 3,600 3,600 1,300 1,700 3,400
FT-A11W P.49
Type 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 51.181 66.929 133.858
Small 3,600 3,600 3,600 3,600 3,600 2,100 3,600 3,600
FT-A32 P.49
Spot 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 82.677 141.732 (Note 2) 141.732 (Note 2)
3,600 3,600 3,600 3,600 3,600 3,000 3,600 3,600
Narrow FT-A32W P.49
Beam
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 118.110 141.732 (Note 2) 141.732 (Note 2)
2,300 1,550 1,500 860 500 170 250 660
FT-AL05 P.49
Wide 90.551 61.024 59.055 33.858 19.685 6.693 9.843 25.984
Beam 52 30 24 15 8 2 6 19
FT-E13 P.49
Convergent 2.047 1.181 0.945 0.591 0.315 0.079 0.236 0.748
Reflective
Type 270 160 125 75 42 13 22 80
FT-E23 P.49
10.630 6.299 4.921 2.953 1.654 0.512 0.866 3.150
Retroreflective
Type Applicable pipe diameter: Outer dia. ø3 to ø10 mm ø0.118 to ø0.394 in transparent pipe
Chemical / Oil- [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 0.3 to 1 mm 0.012 to 0.039 in]
FT-F93 P.49
resistant Liquid absent: Beam interrupted, Liquid present: Beam received
Heat- Compatible amplifier: FX-500 series only
resistant 3,300 1,900 1,300 700 410 140 250 700
FT-H13-FM2 P.49
Vacuum-
129.921 74.803 51.181 27.559 16.142 5.512 9.843 27.559
resistant FT-H20-J20-S (Note 3) 1,600 1,000 790 470 300 90 135 420 P.50
62.992 39.370 31.102 18.504 11.811 3.543 5.315 16.535
Liquid Leak / 1,600 1,000 790 470 300 90 135 420
Liquid Detection FT-H20-J30-S (Note 3) P.50
62.992 39.370 31.102 18.504 11.811 3.543 5.315 16.535
FT-H20-J50-S (Note 3) 1,600 1,000 790 470 300 90 135 420 P.50
62.992 39.370 31.102 18.504 11.811 3.543 5.315 16.535
1,600 1,300 960 540 330 110 210 540
FT-H20-M1 P.50
Fiber 62.992 (Note 2) 51.181 37.795 21.260 12.992 4.331 8.268 21.260
Options FT-H20-VJ50-S (Note 3) 2,100 1,300 980 600 390 120 150 500 P.50
82.677 51.181 38.583 23.622 15.354 4.724 5.906 19.685
FT-H20-VJ80-S (Note 3) 2,100 1,300 980 600 390 120 150 500 P.50
82.677 51.181 38.583 23.622 15.354 4.724 5.906 19.685
Semi-custom 1,600 1,000 840 470 300 90 100 300
FT-H20W-M1 P.50
62.992 (Note 2) 39.370 33.071 18.504 11.811 3.543 3.937 11.811
fibers
FT-H30-M1V-S (Note 4) 1,000 590 470 270 160 55 110 280 P.50
39.370 23.228 18.504 10.630 6.299 2.165 4.331 11.024
1,200 880 670 430 250 80 170 490
FT-H35-M2 P.50
47.244 34.646 26.378 16.929 9.843 3.150 6.693 19.291
Fiber 1,200 880 670 430 250 80 170 490
Dimensions FT-H35-M2S6 P.50
47.244 34.646 26.378 16.929 9.843 3.150 6.693 19.291
Thru-beam 3,600 3,600 3,600 3,600 2,300 740 990 2,340
FT-HL80Y P.50
Type 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 90.551 29.134 38.976 92.126
3,600 3,600 3,600 3,600 3,600 1,200 2,200 3,600
Retroreflective FT-KS40 P.51
Type 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 47.244 86.614 141.732 (Note 2)
2,500 1,600 1,200 710 440 160 135 560
Reflective FT-KV26 P.51
98.425 62.992 47.244 27.953 17.323 6.299 5.315 22.047
Type 3,600 3,600 3,600 3,600 3,600 1,200 2,200 3,600
FT-KV40 P.51
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 47.244 86.614 141.732 (Note 2)
Others
3,600 3,600 3,600 3,600 3,100 940 2,200 3,600
FT-KV40W P.51
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 122.047 37.008 86.614 141.732 (Note 2)
3,600 3,600 3,600 3,600 2,800 920 1,100 2,600
FT-L80Y P.51
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 110.236 36.220 43.307 102.362
1,000 580 440 270 160 55 100 340
FT-R31 P.51
Amplifiers 39.370 22.835 17.323 10.630 6.299 2.165 3.937 13.386
3,600 1,750 1,500 930 500 160 270 740
FX-500 FT-R40 P.51
141.732 (Note 2) 68.898 59.055 36.614 19.685 6.299 10.630 29.134
series 3,200 1,800 1,400 800 460 150 250 710
FT-R41W P.51
FX-100 125.984 70.866 55.118 31.496 18.110 5.906 9.843 27.953
series 3,600 3,600 3,500 2,200 1,300 460 510 2,000
FT-R42W P.51
141.732 (Note 2) 141.732 (Note 2) 137.795 86.614 51.181 18.110 20.079 78.740
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
INDEX 3) Heat-resistant joint fibers and ordinary-temperature fibers (FT-42) are sold as a set.
4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
37
Fibers are listed in alphabetic order.
SENSING RANGE Refer to p. 2~ for details of each fiber. New product
introduction
Thru-beam type (one pair set) Tough
Fiber

Sensing range (mm in) (Note 1)

Model No. FX-500 series FX-100 series Dimensions Fiber


Selection
Guide
HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 Model
3,000 1,600 1,100 720 430 130 210 640
FT-R43 118.110 62.992 43.307 28.346 16.929 5.118 8.268 25.197 P.51 Choose
by shape/
3,000 1,600 1,100 720 430 130 210 640 application
FT-R44Y 118.110 62.992 43.307 28.346 16.929 5.118 8.268 25.197 P.52
How to read
3,600 3,600 3,600 2,100 1,260 400 690 1,890 Model No.
FT-R60Y 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 82.677 49.606 15.748 27.165 74.409 P.52
Earlier models
350 210 160 90 60 19 40 90 comparison
FT-S11 13.780 8.268 6.299 3.543 2.362 0.748 1.575 3.543 P.52 table

1,350 810 650 400 210 75 135 400


FT-S20 53.150 31.890 25.591 15.748 8.268 2.953 5.315 15.748 P.52
1,350 770 550 315 210 70 130 340
FT-S21 53.150 30.315 21.654 12.402 8.268 2.756 5.118 13.386 P.52
Fibers
990 590 440 260 150 53 80 240
FT-S21W 38.976 23.228 17.323 10.236 5.906 2.087 3.150 9.449 P.52
Super
3,600 2,200 1,700 1,200 530 190 320 870 Quality
FT-S30 141.732 (Note 2) 86.614 66.929 47.244 20.866 7.480 12.598 34.252 P.52
Threaded
3,300 1,900 1,400 800 490 160 260 720 Type
FT-S31W 129.921 74.803 55.118 31.496 19.291 6.299 10.236 28.346 P.52
3,600 3,600 3,600 3,100 1,800 600 1,100 3,000 Square Head
FT-S32 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 122.047 70.866 23.622 43.307 118.110 P.52 Type
1,800 1,000 880 450 280 90 160 400 Cylindrical
FT-V23 70.866 39.370 34.646 17.717 11.024 3.543 6.299 15.748 P.52 Type
380 230 200 110 60 20 35 90
FT-V24W 14.961 9.055 7.874 4.331 2.362 0.787 1.378 3.543 P.53 Sleeve
900 550 480 240 140 45 95 260
FT-V25 35.433 21.654 18.898 9.449 5.512 1.772 3.740 10.236 P.53 Flat
Type
2,200 1,200 1,000 680 340 100 180 480
FT-V30 86.614 47.244 39.370 26.772 13.386 3.937 7.087 18.898 P.53 Small
3,600 3,600 3,600 3,500 2,400 850 1,000 3,100 Spot
FT-V40 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 94.488 33.465 39.370 122.047 P.53
Narrow
3,600 2,800 2,200 1,300 800 240 340 800 Beam
FT-V80Y 141.732 (Note 2) 110.236 86.614 51.181 31.496 9.449 13.386 31.496 P.53
Wide
1,100 670 570 260 180 55 100 320
FT-Z20HBW 43.307 26.378 22.441 10.236 7.087 2.165 3.937 12.598 P.53 Beam
Convergent
1,600 1,500 1,100 620 420 130 280 730
FT-Z20W 62.992 (Note 2) 59.055 43.307 24.409 16.535 5.118 11.024 28.740 P.53 Reflective
Type
3,600 3,600 3,600 2,100 1,200 410 710 2,300 Retroreflective
FT-Z30 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 82.677 47.244 16.142 27.953 90.551 P.53
Type
3,600 3,600 3,600 3,500 2,400 740 1,200 3,200
FT-Z30E 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 94.488 29.134 47.244 125.984 P.53 Chemical / Oil-
resistant
3,600 3,600 3,600 3,400 2,000 630 1,400 2,600
FT-Z30EW 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 133.858 78.740 24.803 55.118 102.362 P.54 Heat-
3,600 3,600 3,600 3,500 2,600 810 1,400 3,200 resistant
FT-Z30H 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 102.362 31.890 55.118 125.984 P.54
Vacuum-
3,600 3,600 3,600 3,500 2,600 810 1,400 3,200 resistant
FT-Z30HW 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 102.362 31.890 55.118 125.984 P.54
Liquid Leak /
3,600 3,300 3,200 1,500 1,000 280 540 1,800 Liquid Detection
FT-Z30W 141.732 (Note 2) 129.921 125.984 59.055 39.370 11.024 21.260 70.866 P.54
3,300 1,900 1,400 800 490 160 260 720
FT-Z40HBW 129.921 74.803 55.118 31.496 19.291 6.299 10.236 28.346
P.54
3,600 3,300 2,300 1,500 900 290 410 1,200
FT-Z40W 141.732 (Note 2) 129.921 90.551 59.055 35.433 11.417 16.142 47.244 P.54 Fiber
3,600 3,600 3,600 3,100 1,900 470 520 3,100 Options
FT-Z802Y 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 122.047 74.803 18.504 20.472 122.047 P.54

Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
38
Fibers are listed in alphabetic order.
New product SENSING RANGE Refer to p. 2~ for details of each fiber.
introduction
Tough
Fiber Retroreflective type

Sensing range (mm in) (Note 1, 2)

Fiber Model No. FX-500 series FX-100 series Dimensions


Selection
Guide

Model HYPR U-LG LONG STD FAST H-SP FX-101 FX-102


Choose 15 to 570 15 to 460 15 to 410 15 to 310 15 to 220 15 to 100 15 to 200 15 to 360
FR-KZ22E P.55
by shape/
application
0.591 to 22.441 0.591 to 18.110 0.591 to 16.142 0.591 to 12.205 0.591 to 8.661 0.591 to 3.937 0.591 to 7.874 0.591 to 14.173
How to read 20 to 1,000 20 to 800 20 to 400 20 to 300 20 to 200 20 to 200 20 to 200 20 to 350
FR-KZ50E P.55
Model No 0.787 to 39.370 0.787 to 31.496 0.787 to 15.748 0.787 to 11.811 0.787 to 7.874 0.787 to 7.874 0.787 to 7.874 0.787 to 13.780
Earlier models 20 to 1,000 20 to 800 20 to 400 20 to 300 20 to 200 20 to 200 20 to 200 20 to 350
comparison FR-KZ50H P.55
table 0.787 to 39.370 0.787 to 31.496 0.787 to 15.748 0.787 to 11.811 0.787 to 7.874 0.787 to 7.874 0.787 to 7.874 0.787 to 13.780
100 to 1,900 100 to 1,400 100 to 1,200 100 to 990 100 to 780 100 to 490 100 to 550 100 to 830
FR-Z50HW P.55
3.937 to 74.803 3.937 to 55.118 3.937 to 47.244 3.937 to 38.976 3.937 to 30.709 3.937 to 19.291 3.937 to 21.654 3.937 to 32.677
Notes: 1) Note
‌ that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Fibers The sensing range of FR-Z50HW is specified for the RF-13. The sensing range of FR-KZ50H and FR-KZ50E is specified for the
attached reflector RF-003. The sensing range of FR-KZ22E is specified for the attached reflector.
Super 2) ‌The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range
Quality
for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber
Threaded head. If this occurs, adjust the threshold value of the amplifier unit before use.
Type
Square Head
Type
Cylindrical
Sensing range when FR-Z50HW is used in combination with a reflector (optional)
Type

Sleeve Sensing range (mm in)


Reflector
Flat FX-500 series FX-100 series
Type Model No.
HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
Small
Spot 100 to 19,000 100 to 8,000 100 to 5,000 100 to 3,600 100 to 2,900 100 to 1,400 100 to 2,400 100 to 5,000
RF-230
3.937 to 748.03 3.937 to 314.960 3.937 to 196.850 3.937 to 141.732 3.937 to 114.173 3.937 to 55.118 3.937 to 94.488 3.937 to 196.850
Narrow
Beam 100 to 8,000 100 to 4,700 100 to 3,500 100 to 3,000 100 to 1,800 100 to 830 100 to 1,300 100 to 2,600
RF-220
3.937 to 314.960 3.937 to 185.039 3.937 to 137.795 3.937 to 118.110 3.937 to 70.866 3.937 to 32.677 3.937 to 51.181 3.937 to 102.362
Wide
Beam 100 to 5,500 100 to 2,700 100 to 2,400 100 to 1,500 100 to 1,200 100 to 530 100 to 980 100 to 1,300
RF-210
Convergent 3.937 to 216.535 3.937 to 106.299 3.937 to 94.488 3.937 to 59.055 3.937 to 47.244 3.937 to 20.866 3.937 to 38.583 3.937 to 51.181
Reflective
Type Note: 1) The
‌ sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than 100 mm 3.937
Retroreflective in. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this oc-
Type curs, adjust the threshold value of the amplifier unit before use.
Chemical / Oil-
resistant
Heat-
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
39
Fibers are listed in alphabetic order.
SENSING RANGE Refer to p. 2~ for details of each fiber. New product
introduction
Tough
Reflective type Fiber

Sensing range (mm in) (Note 1, 2)

Model No. FX-500 series FX-100 series Dimensions Fiber


Selection
Guide
HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 Model
600 330 250 160 80 25 45 155
FD-30 23.622 12.992 P.56 Choose
9.843 6.299 3.150 0.984 1.772 6.102 by shape/
515 290 220 125 80 25 35 140 application
FD-31 P.56
20.276 11.417 8.661 4.921 3.150 0.984 1.378 5.512 How to read
330 180 140 80 45 12 15 60 Model No.
FD-31W P.56
12.992 7.087 5.512 3.150 1.772 0.472 0.591 2.362 Earlier models
comparison
650 380 270 200 95 27 70 190 table
FD-32G P.56
25.591 14.961 10.630 7.874 3.740 1.063 2.756 7.480
630 410 360 200 100 30 75 210
FD-32GX P.56
24.803 16.142 14.173 7.874 3.937 1.181 2.953 8.268
600 330 250 160 80 25 45 155
FD-40 P.56
23.622 12.992 9.843 6.299 3.150 0.984 1.772 6.102 Fibers
515 290 220 125 80 25 35 140
FD-41 P.56
20.276 11.417 8.661 4.921 3.150 0.984 1.378 5.512 Super
515 290 220 125 80 25 35 140 Quality
FD-41S P.56
20.276 11.417 8.661 4.921 3.150 0.984 1.378 5.512 Threaded
330 180 140 80 45 12 15 60 Type
FD-41SW P.56
12.992 7.087 5.512 3.150 1.772 0.472 0.591 2.362
Square Head
900 630 430 270 150 45 80 230 Type
FD-41W P.56
35.433 24.803 16.929 10.630 5.906 1.772 3.150 9.055
650 380 270 200 95 27 70 190 Cylindrical
FD-42G P.57 Type
25.591 14.961 10.630 7.874 3.740 1.063 2.756 7.480
670 340 280 150 90 25 45 140
FD-42GW P.57 Sleeve
26.378 13.386 11.024 5.906 3.543 0.984 1.772 5.512
1,550 900 740 520 260 90 140 420
FD-60 P.57 Flat
61.024 35.433 29.134 20.472 10.236 3.543 5.512 16.535 Type
1,400 840 670 450 200 70 120 410
FD-61 P.57 Small
55.118 33.071 26.378 17.717 7.874 2.756 4.724 16.142
1,100 800 650 420 200 60 120 350 Spot
FD-61G P.57
43.307 31.496 25.591 16.535 7.874 2.362 4.724 13.780 Narrow
1,200 790 660 420 220 75 130 360 Beam
FD-61S P.57
47.244 31.102 25.984 16.535 8.661 2.953 5.118 14.173 Wide
900 630 430 270 150 45 80 230 Beam
FD-61W P.57
35.433 24.803 16.929 10.630 5.906 1.772 3.150 9.055 Convergent
1,500 1,000 940 520 340 110 170 450 Reflective
FD-62 P.57
59.055 39.370 37.008 20.472 13.386 4.331 6.693 17.717 Type
670 500 410 280 160 50 75 220 Retroreflective
FD-64X P.58 Type
26.378 19.685 16.142 11.024 6.299 1.969 2.953 8.661
FD-A16 200 200 200 140 75 120 240 Chemical / Oil-
P.58
7.874 7.874 7.874 5.512 2.953 4.724 9.449 resistant
670 530 510 320 180 50 100 285
FD-AL11 P.58 Heat-
26.378 20.866 20.079 12.598 7.087 1.969 3.937 11.220
resistant
50 29 25 12 7 2 5 15
FD-E13 P.58
1.969 1.142 0.984 0.472 0.276 0.079 0.197 0.591 Vacuum-
170 120 80 55 30 9 20 70 resistant
FD-E23 P.58
6.693 4.724 3.150 2.165 1.181 0.354 0.787 2.756 Liquid Leak /
170 130 110 48 30 9 20 70 Liquid Detection
FD-EG30 P.58
6.693 5.118 4.331 1.890 1.181 0.354 0.787 2.756
170 110 80 50 30 9 20 70
FD-EG30S 6.693 4.331 3.150 1.969 1.181 0.354 0.787 2.756 P.59
85 45 35 20 12 3.5 7 25
FD-EG31 P.59 Fiber
3.346 1.772 1.378 0.787 0.472 0.138 0.276 0.984
Options
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe
FD-F4 [PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in] P.59
Liquid absent: Beam received, Liquid present: Beam interrupted
Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe Semi-custom
FD-F41 [PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in] P.59 fibers
Liquid absent: Beam received, Liquid present: Beam interrupted
ø4 mm ø0.157 in
FD-F41Y (Note 3) Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) P.59 Fiber
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted Dimensions
Liquid leak detection Thru-beam
Type
FD-F71 Leak absent: Beam received, Leak present: Beam interrupted P.59
Compatible amplifier: FX-500 series only Retroreflective
Type
ø6 mm ø0.236 in Reflective
FD-F8Y Protective tube: Fluorine resin, length 1,000 mm 39.370 in (not cuttable) P.59 Type
Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted
Others
Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe
(When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in)
FD-FA93 P.59
[PFA (fluorine resin), including translucent]
Liquid absent: Beam received, Liquid present: Beam interrupted
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Amplifiers
2) ‌The sensing range is specified for white non-glossy paper. FX-500
3) ‌Liquid inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to page 35 for details. series
FX-100
series

INDEX
40
Fibers are listed in alphabetic order.
New product SENSING RANGE Refer to p. 2~ for details of each fiber.
introduction
Tough
Fiber Reflective type

Sensing range (mm in) (Note 1, 2)


Fiber Model No. FX-500 series FX-100 series Dimensions
Selection
Guide

Model HYPR U-LG LONG STD FAST H-SP FX-101 FX-102


880 640 600 350 200 65 100 280
Choose FD-H13-FM2 25.197 23.622 13.780 7.874 2.559 3.937 11.024 P.60
by shape/ 34.646
application
FD-H18-L31 60 32 24 16 13 2 to 6.5 0 to 10 0 to 25 P.60
How to read 2.362 1.260 0.945 0.630 0.512 0.079 to 0.256 0 to 0.394 0 to 0.984
Model No 770 500 380 230 130 45 90 280
Earlier models
FD-H20-21 30.315 19.685 14.961 9.055 5.118 1.772 3.543 11.024 P.60
comparison
table FD-H20-M1 840 550 500 330 200 55 120 300 P.60
33.071 21.654 19.685 12.992 7.874 2.165 4.724 11.811
FD-H25-L43 (Note 3) 1 to 31 1 to 30 1 to 28 1.5 to 26 1.5 to 24 2 to 18 4 to 16 4 to 23 P.60
0.039 to 1.220 0.039 to 1.181 0.039 to 1.102 0.059 to 1.024 0.059 to 0.945 0.079 to 0.709 0.157 to 0.630 0.157 to 0.906
FD-H25-L45 (Note 3) 4 to 43.5 4 to 43 4.5 to 43 5 to 42 5 to 40 6.5 to 34 7 to 35 7 to 38 P.60
Fibers 0.157 to 1.713 0.157 to 1.693 0.177 to 1.693 0.197 to 1.654 0.197 to 1.575 0.256 to 1.339 0.276 to 1.378 0.276 to 1.496

Super
FD-H30-KZ1V-S (Note 3, 4) 0.197 to519.685
to 500 10 to 340 15 to 270 20 to 200 20 to120
0.394 to 13.386 0.591 to 10.630 0.787 to 7.874 0.787 to 4.724
20 to 45
0.787 to 1.772
25 to 80 10 to 220
0.984 to 3.150 0.394 to 8.661 P.61
Quality 40 30 25 17 12 1.5 to 6 2 to 9 0 to 17
FD-H30-L32 1.575 1.181 0.984 0.669 0.472 0.059 to 0.236 0.079 to 0.354 0 to 0.669 P.61
Threaded
Type FD-H30-L32V-S (Note 3, 4) 18 12 10 8 5.5 1.5 to 3 2.5 to 6.5 0 to11 P.61
0.709 0.472 0.394 0.315 0.217 0.059 to 0.118 0.098 to 0.256 0 to 0.433
Square Head
Type FD-H35-20S 840 550 440 260 140 45 85 200 P.61
33.071 21.654 17.323 10.236 5.512 1.772 3.346 7.874
Cylindrical 720 540 460 260 150 45 75 280
Type FD-H35-M2 28.346 21.260 18.110 10.236 5.906 1.772 2.953 11.024 P.61

FD-H35-M2S6 720 540 460 260 150 45 75 280 P.61


Sleeve 28.346 21.260 18.110 10.236 5.906 1.772 2.953 11.024
Flat ø4 mm ø0.157 in
Type FD-HF40Y (Note 5) Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) P.61
Small Liquid surface not contacted: Beam received, Liquid surface contacted: Beam not received
Spot 0 to 6 0 to 5.5 0 to 5.5 0 to 5 0 to 4.5 0 to 4 0 to 4.5 0 to 5.5
FD-L10 (Note 3) 0 to 0.236 0 to 0.217 0 to 0.217 0 to 0.197 0 to 0.177 0 to 0.157 0 to 0.177 0 to 0.217 P.62
Narrow
Beam FD-L11 (Note 3) 0 to 11.5 0 to 10.5 0 to 10 0 to 9.5 0 to 9 0 to 8 0 to 8 0 to 9 P.62
0 to 0.453 0 to 0.413 0 to 0.394 0 to 0.374 0 to 0.354 0 to 0.315 0 to 0.315 0 to 0.354
Wide
Beam FD-L12W (Note 3) 14 12.5 12 8 0.5 to 7 0.5 to 4 1 to 4.5 0.5 to 7 P.62
0.551 0.492 0.472 0.315 0.020 to 0.276 0.020 to 0.157 0.039 to 0.177 0.020 to 0.276
Convergent
Reflective FD-L20H 45 35 32 23 2 to 15 5 to 9 5 to 15 1 to 30 P.62
Type 1.772 1.378 1.260 0.906 0.079 to 0.591 0.197 to 0.354 0.197 to 0.591 0.039 to 1.181
Retroreflective FD-L21 (Note 3) 1 to 19 1 to 18 1 to 18 1.5 to 16 2 to 15 3 to 12 3 to 15 1.5 to 16 P.62
Type 0.039 to 0.748 0.039 to 0.709 0.039 to 0.709 0.059 to 0.630 0.079 to 0.591 0.118 to 0.472 0.118 to 0.591 0.059 to 0.630
Chemical / Oil- FD-L21W (Note 3) 1.5 to 15 2 to 15 2 to 15 3 to 14 4 to 14 6.5 to 10 7 to 12 3 to 14 P.62
resistant 0.059 to 0.591 0.079 to 0.591 0.079 to 0.591 0.118 to 0.551 0.158 to 0.551 0.256 to 0.394 0.276 to 0.472 0.118 to 0.551
FD-L22A (Note 3) 0 to 31 0 to 28 0 to 27 0 to 24 0 to 24 0 to 18 0 to 19 0 to 25 P.62
Heat- 0 to 1.220 0 to 1.102 0 to 1.063 0 to 0.945 0 to 0.945 0 to 0.709 0 to 0.748 0 to 0.984
resistant
FD-L23 (Note 3) 0 to 30 0 to 30 0 to 30 0 to 29 0 to 28 1.5 to 24 0 to 28 0 to 30 P.62
Vacuum- 0 to 1.181 0 to 1.181 0 to 1.181 0 to 1.142 0 to 1.102 0.059 to 0.945 0 to 1.102 0 to 1.181
resistant 0 to 43 0 to 43 0 to 43 0 to 43 0 to 42 0 to 29 0 to 40 0 to 50
FD-L30A (Note 3) 0 to 1.693 0 to 1.693 0 to 1.693 0 to 1.693 0 to 1.654 0 to 1.142 0 to 1.575 0 to 1.969 P.62
Liquid Leak /
Liquid Detection FD-L31A (Note 3) 3 to 35 4 to 33 4 to 33 4 to 33 4 to 32 5 to 25 5 to 30 4 to 33 P.62
0.118 to 1.378 0.157 to 1.299 0.157 to 1.299 0.157 to 1.299 0.157 to 1.260 0.197 to 0.984 0.197 to 1.181 0.157 to 1.299
FD-L32H (Note 3) 0 to 110 0 to 87 0 to 74 0 to 56 1 to 38 - 16 to 30 0 to 50 P.63
0 to 4.331 0 to 3.425 0 to 2.913 0 to 2.205 0.039 to 1.496 0.630 to 1.181 0 to 1.969
FD-R31G 530 310 260 170 85 27 45 150 P.63
Fiber 20.866 12.205 10.236 6.693 3.346 1.063 1.772 5.906
Options 170 110 92 45 30 9 20 68
FD-R32EG 6.693 4.331 3.622 1.772 1.181 0.354 0.787 2.677 P.63

FD-R33EG 84 44 33 19 11 3 7 22 P.63
3.307 1.732 1.299 0.748 0.433 0.118 0.276 0.866
Semi-custom FD-R34EG 130 90 70 38 23 7 17 60 P.63
fibers 5.118 3.543 2.756 1.496 0.906 0.276 0.669 2.362
FD-R41 710 430 320 210 100 34 60 170 P.63
27.953 16.929 12.598 8.268 3.937 1.339 2.362 6.693
FD-R60 1,100 600 550 290 190 65 110 240 P.63
43.307 23.622 21.654 11.417 7.480 2.559 4.331 9.449
Fiber
Dimensions 990 610 435 280 160 50 85 185
FD-R61Y 11.024 P.63
38.976 24.016 17.126 6.299 1.969 3.346 7.283
Thru-beam 190 130 110 80 37 11 25 70
Type FD-S21 7.480 5.118 4.331 3.150 1.457 0.433 0.984 2.756 P.63
Retroreflective FD-S30 600 330 250 160 80 25 45 155 P.64
Type 23.622 12.992 9.843 6.299 3.15 0.984 1.772 6.102
Reflective FD-S31 515 290 220 125 80 25 35 140 P.64
Type 20.276 11.417 8.661 4.921 3.15 0.984 1.378 5.512
FD-S32 1,200 790 660 420 220 75 120 345 P.64
Others 47.244 31.102 25.984 16.535 8.661 2.953 4.724 13.583

Notes: 1) N
 ote that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) ‌The sensing range of reflective type is the value for white non-glossy paper (as for FD-H30-L32 and FD-H18-L31 50 × 50 mm 1.969 × 1.969 in glass
substrate).
3) ‌The sensing range is specified for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm
Amplifiers
t0.079 in) [FD-L10: silicon wafers 100 × 100 mm 3.937 × 3.937 in].
FX-500 4) Sold
‌ as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8).
series 5) Liquid
‌ inflow prevention joint, protective tube extension joint, fiber mounting joint are available. Please refer to page 35 for details.
FX-100
series

INDEX
41
Fibers are listed in alphabetic order.
SENSING RANGE Refer to p. 2~ for details of each fiber. New product
introduction
Tough
Reflective type Fiber

Sensing range (mm in) (Note 1, 2)

Model No. FX-500 series FX-100 series Dimensions Fiber


Selection
Guide
HYPR U-LG LONG STD FAST H-SP FX-101 FX-102 Model
900 630 430 270 150 45 80 230
FD-S32W P.64 Choose
35.433 24.803 16.929 10.630 5.906 1.772 3.150 9.055 by shape/
670 340 280 150 90 25 45 140 application
FD-S33GW P.64
26.378 13.386 11.024 5.906 3.543 0.984 1.772 5.512 How to read
600 590 420 320 200 75 140 300 Model No.
FD-S60Y P.64
23.622 23.228 16.535 12.598 7.874 2.953 5.512 11.811 Earlier models
comparison
240 130 120 65 35 14 25 75
FD-V30 P.64 table
9.449 5.118 4.724 2.559 1.378 0.551 0.984 2.953
80 40 30 20 10 2 6 20
FD-V30W P.64
3.150 1.575 1.181 0.787 0.394 0.079 0.236 0.787
370 220 210 120 75 25 40 100
FD-V50 P.65
14.567 8.661 8.268 4.724 2.953 0.984 1.575 3.937 Fibers
FD-Z20HBW 1 to 340 1 to 210 1 to 180 2 to 85 2 to 55 3 to 15 2 to 30 1 to 90 P.65
0.039 to 13.386 0.039 t 8.268 0.039 to 7.087 0.079 to 3.346 0.079 to 2.165 0.118 to 0.591 0.079 to 1.181 0.039 to 3.543 Super
260 150 130 1 to 65 2 to 45 5 to 13 2 to 32 1 to 80 Quality
FD-Z20W P.65
10.236 5.906 5.118 0.039 to 2.559 0.079 to 1.772 0.197 to 0.512 0.079 to 1.260 0.039 to 3.150 Threaded
760 540 470 260 1 to 160 2 to 50 1 to 90 0.5 to 240 Type
FD-Z40HBW P.65
29.921 21.260 18.504 10.236 0.039 to 6.299 0.079 to 1.969 0.039 to 3.543 0.020 to 9.449
Square Head
790 440 390 190 1 to 120 2 to 35 1 to 74 200
FD-Z40W P.65 Type
31.102 17.323 15.354 7.480 0.039 to 4.724 0.079 to 1.378 0.039 to 2.913 7.874
10 to 2,500 10 to 1,100 10 to 1,000 10 to 650 10 to 410 15 to 130 10 to 200 10 to 530 Cylindrical
FD-Z50HW (Note 3) P.65 Type
0.394 to 98.425 0.394 to 43.307 0.394 to 39.370 0.394 to 25.591 0.394 to 16.142 0.591 to 5.118 0.394 to 7.874 0.394 to 20.866
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Sleeve
2) ‌The sensing range is specified for white non-glossy paper (except for FD-Z50HW).
3) ‌The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. Flat
Refer to P.38 for the sensing range when FR-Z50HW is used in combination with a reflector (optional). Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
42

New product FIBER OPTIONS Refer to p.66~ for details of lens dimensions.
introduction
Lens (For thru-beam type fiber)
Tough
Fiber Designation Model No. Description
Increases the sensing range by 5 times or more. • Ambient temperature: -60 to +350 °C -76 to +662 °F (Note 4) • Beam dia: ø3.6 mm ø0.142 in
Sensing range (mm in) [Lens on both sides]
Fiber Amplifier FX-500 series FX-100 series
Selection Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
Guide
FT-43 3,600 3,600 3,600 3,600 3,600 1,600 2,400 3,600
Model 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 62.992 94.488 141.732 (Note 2)
FT-42 3,600 3,600 3,600 3,600 3,600 2,200 3,400 3,600
Choose FT-42W 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 86.614 133.858 141.732 (Note 2)
by shape/
application FT-45X 1,600 1,600 1,600 1,600 1,600 1,500 1,600 1,600
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 59.055 62.992 (Note 2) 62.992 (Note 2)
How to read
Model No FT-R40 3,600 3,600 3,600 3,600 3,600 1,900 3,100 3,600
Expansion 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 74.803 122.047 141.732 (Note 2)
Earlier models
comparison
lens FX-LE1 3,600 3,600 3,600 3,600 3,600 2,200 3,400 3,600
FT-R42W
table (Note 1) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 86.614 133.858 141.732 (Note 2)
FT-R43 3,600 3,600 3,600 3,600 1,900 670 1,300 3,600
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 74.803 26.378 51.181 141.732 (Note 2)
FT-H35-M2 3,600 3,600 3,600 3,600 3,300 1,400 2,000 3,500
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 129.921 55.118 78.740 137.795 (Note 2)
Fibers FT-H20W-M1 1,600 1,600 1,600 1,600 1,600 850 1,300 1,600
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 33.465 51.181 62.992 (Note 2)
Super FT-H20-M1 1,600 1,600 1,600 1,600 1,600 1,200 1,600 1,600
Quality 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 47.244 62.992 (Note 2) 62.992 (Note 2)
Threaded FT-H20-J50-S
FT-H20-J30-S 3,600 3,600 3,500 2,000 1,600 500 1,000 3,500
Type 141.732 (Note 2) 141.732 (Note 2) 137.795 78.740 62.992 19.685 39.370 137.795 (Note 2)
FT-H20-J20-S
Square Head
Type Tremendously increases the sensing range with large diameter lenses. • Ambient temperature: -60 to +350 °C -76 to +662 °F (Note 4) • Beam dia: ø9.8 mm ø0.386 in
Sensing range (mm in) [Lens on both sides]
Cylindrical
Type Amplifier FX-500 series FX-100 series
Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
Sleeve FT-43
FT-42 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,600
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
Flat FT-42W
Type 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600
FT-45X 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2)
Small
Spot FT-R40 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,600
Super- 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
Narrow expansion 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,600
Beam FX-LE2 FT-R42W 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
lens
Wide (Note 1) FT-R43 3,600 3,600 3,600 3,600 3,600 3,600 3,600 3,600
Beam 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2)
Convergent FT-H35-M2 3,600 3,600 3,600 3,600 3,600 3,600 3,500 3,500
Reflective 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2)
Type FT-H20W-M1 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600
Retroreflective FT-H20-M1 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2)
Type FT-H13-FM2 3,600 3,600 3,600 3,600 3,600 3,600 3,500 3,500
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2)
Chemical / Oil-
resistant FT-H20-J50-S
FT-H20-J30-S 3,600 3,600 3,600 3,600 3,600 3,600 3,500 3,500
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 137.795 (Note 2) 137.795 (Note 2)
Heat- FT-H20-J20-S
resistant
Beam axis is bent by 90°. • Ambient temperature: -60 to +300 °C -76 to +572 °F (Note 4) • Beam dia: ø2.8 mm ø0.110 in
Vacuum- Sensing range (mm in) [Lens on both sides]
resistant Amplifier FX-500 series FX-100 series
Liquid Leak / Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
Liquid Detection
FT-43 3,600 3,400 2,600 1,700   970 310 510 1,400
141.732 (Note 2) 133.858 102.362 66.929 38.189 12.205 20.079 55.118
FT-42 3,600 3,600 3,600 2,100 1,150 370 500 1,700
141.732 (Note 2) 141.732 (Note 2) 141.732 (Note 2) 82.677 45.276 14.567 19.685 66.929
Fiber FT-42W 3,600 3,500 2,700 1,800   990 320 480 1,300
141.732 (Note 2) 137.795 106.299 70.866 38.976 12.598 18.898 51.181
Options
FT-45X 1,600 1,600 1,600 1,400   800 210 540 1,600
62.992 (Note 2) 62.992 (Note 2) 62.992 (Note 2) 55.118 31.496 8.268 21.260 62.992 (Note 2)
Side-view
FX-SV1 3,600 3,500 2,700 1,800 990 320 1,400 1,000
lens FT-R42W 141.732 (Note 2) 137.795 106.299 70.866 38.976 12.598 55.118 39.370
Semi-custom FT-R43 3,200 1,800 1,300 950 510 160 310 930
fibers 125.984 70.866 51.181 37.402 20.079 6.299 12.205 36.614
FT-H35-M2 3,500 1,600 1,200   780   500 150 280   800
137.795 62.992 47.244 30.709 19.685 5.906 11.024 31.496
FT-H20W-M1 1,600 1,600 1,500   950   560 190 140   400
62.992 (Note 2) 62.992 (Note 2) 59.055 37.402 22.047 7.480 5.512 15.748
Fiber 1,600 1,600 1,300   780   500 150 280   840
FT-H20-M1
Dimensions 62.992 (Note 2) 62.992 (Note 2) 51.181 30.709 19.685 5.906 11.024 33.071
Thru-beam FT-H20-J50-S
FT-H20-J30-S 1,600   960   740   450   290 80 150   410
Type 62.992 (Note 2) 37.795 29.134 17.717 11.417 3.150 5.906 16.142
FT-H20-J20-S
Retroreflective
Type Sensing range increases by 4 times or more. • Ambient temperature: -60 to +350 °C -76 to +662 °F (Note 4) • Beam dia: ø3.6 mm ø0.142 in
Expansion Sensing range (mm in) [Lens on both sides] (Note 3)
Reflective lens for
Type Amplifier FX-500 series FX-100 series
vacuum FV-LE1 Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
Others fiber 3,600 3,600 3,400 1,500 900 370 450 1,600
(Note 1) FT-H30-M1V-S
141.732 (Note 2) 141.732 (Note 2) 133.858 59.055 35.433 14.567 17.717 62.992

Beam axis is bent by 90°. • Ambient temperature: -60 to +300 °C -76 to +572 °F (Note 4) • Beam dia: ø3.7 mm ø0.146 in
Vacuum- Sensing range (mm in) [Lens on both sides] (Note 3)
resistant Amplifier FX-500 series FX-100 series
Amplifiers side-view FV-SV2 Fiber Mode HYPR U-LG LONG STD FAST H-SP FX-101 FX-102
lens
FX-500 FT-H30-M1V-S 3,600 3,600 3,400 1,500 900 370 450 1,600
series (Note 1) 141.732 (Note 2) 141.732 (Note 2) 133.858 59.055 35.433 14.567 17.717 62.992
FX-100 Notes: 1) Be careful sure to use it only after you have adjusted it sufficiently when installing the thru-beam type fiber equipped with the expansion lens, as the
series
beam envelope becomes narrow and alignment is difficult.
2) The fiber cable length practically limits the sensing range.
3) The fiber cable length for the FT-H30-M1V-S is 1 m 3.28 ft. The sensing ranges in HYPR, U-LG and LONG of FX-500 series and in FX-102 are speci-
fied considering the length of the FT-J8 atmospheric side fiber.
INDEX 4) Refer to p.12, p.15, p.30 and p.32 for the ambient temperature of fibers to be used in combination.
43

FIBER OPTIONS Refer to p.66~ for details of lens dimensions. New product
introduction
Tough
Lens (For reflective type fiber) Fiber

Designation Model No. Description


Fiber
Selection
Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks. Guide
Pinpoint
spot lens
FX-MR1 • Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in • Applicable fibers: FD-42G, FD-42GW Model
• Ambient temperature: -40 to +70 °C -40 to +158 °F (Note) Choose
by shape/
The spot diameter is adjustable from ø0.7 to ø2 Sensing range for FX-500/FX-100 series application
Screw-in mm ø0.028 to ø0.079 in according to how much How to read
depth
the fiber is screwed in. Screw-in depth Distance to focal point Spot diameter Model No.
• Applicable fibers: FD-42G, FD-42GW 7 mm 18.5 mm approx. ø0.7 mm Earlier models
Zoom lens FX-MR2 comparison
Distance to • Ambient temperature:-40 to +70 °C table
focal point
-40 to +158 °F (Note) 12 mm 27 mm approx. ø1.2 mm
Spot • Accessory: MS-EX3 (mounting bracket)
diameter 14 mm 43 mm approx. ø2.0 mm

Extremely fine spot of ø0.15 mm ø0.006 in Sensing range for FX-500/FX-100 series Fibers
approx. achieved. Fiber model No. Distance to focal point Spot diameter
• Applicable fibers: Super
Quality
For reflective type fiber

Finest spot FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-EG31 7.5 ± 0.5 mm ø0.15 mm approx.
lens
FX-MR3 FD-32G, FD-32GX Threaded
FD-EG30 7.5 ± 0.5 mm ø0.3 mm approx. Type
• Ambient temperature: -40 to +70 °C
-40 to +158 °F (Note) FD-42G/42GW Square Head
7.5 ± 0.5 mm ø0.5 mm approx. Type
FD-32G/32GX
Distance to Cylindrical
focal point Type
Extremely fine spot of ø0.1 mm ø0.004 in Sensing range for FX-500/FX-100 series
approx. achieved. Fiber model No. Distance to focal point Spot diameter Sleeve
Spot diameter
• Applicable fibers:
FD-EG31, FD-EG30, FD-42G, FD-42GW, FD-EG31 7 ± 0.5 mm ø0.1 mm approx. Flat
Finest spot Type
lens
FX-MR6 FD-32G, FD-32GX
FD-EG30 7 ± 0.5 mm ø0.2 mm approx.
• Ambient temperature: -20 to +60 °C Small
-4 to +140 °F (Note) FD-42G/42GW Spot
7 ± 0.5 mm ø0.4 mm approx.
FD-32G/32GX Narrow
Beam

Sensing range for FX-500/FX-100 series Wide


Screw-in FX-MR2 is converted into a side-view type and
depth Beam
can be mounted in a very small space. Screw-in depth Distance to focal point Spot diameter Convergent
Zoom lens • Applicable fibers: FD-42G, FD-42GW Reflective
side-view FX-MR5 • Ambient temperature: -40 to +70 °C 8 mm 13 mm approx. ø0.5 mm
Type

type Distance to Retroreflective


focal point -40 to +158 °F (Note) 10 mm 15 mm approx. ø0.8 mm Type
Spot diameter 14 mm 30 mm approx. ø3.0 mm Chemical / Oil-
resistant
Note: Refer to p.13 or p.23 for the ambient temperature of fibers to be used in combination. Heat-
resistant
Vacuum-
resistant
Lens (For square head M3 reflective fiber) Liquid Leak /
Distance to Lens Fiber Liquid Detection
Spot diameter
Type focal point Shape Emitting fiber
(mm in) (mm in) Model No. Shape Model No.
(mm in) core (mm in)
ø0.125 ø0.005 FD-R33EG Fiber
ø0.1 ø0.004 Options
approx.
ø0.125 ø0.005 FD-EG31
For Square head M3 reflective fiber

ø0.15 ø0.006 ø0.175 ø0.007 FD-R34EG


approx.
Semi-custom
ø0.25 ø0.010 FD-R32EG fibers
ø0.2 ø0.008
approx. 15.3
0.602 ø0.25 ø0.010 FD-EG30
Finest spot 7 ± 0.5 FX-MR7
lens 0.276 ± 0.020 ø5 ø0.197
ø0.5 ø0.020 FD-R31G Fiber
Dimensions
ø0.5 ø0.020 FD-32G Thru-beam
ø0.4 ø0.016 Type
approx. ø0.5 ø0.020 FD-32GX
Retroreflective
Type
ø0.5 ø0.020 FD-42G
Reflective
ø0.5 ø0.020 FD-42GW Type

Others
Sensing Lens Applicable fibers
Spot diameter
Type range Shape Model No. Emitting
(mm in) fiber
(mm in) Model No.
(mm in) core (mm in)
ø0.4 to ø2.0 ø0.016 to ø0.079 approx. 15 ø0.125 ø0.005 FD-R33EG, FD-EG31 Amplifiers
Zoom lens

ø0.4 to ø2.2 ø0.016 to ø0.087 approx. 0.591 ø0.175 ø0.007 FD-R34EG


For Square head M3

10 to 30 FX-MR8 FX-500
ø0.5 to ø2.5 ø0.020 to ø0.098 approx. 0.394 to1.181
ø5 ø0.197 series
reflective fiber

ø0.25 ø0.010 FD-R32EG, FD-EG30


ø0.8 to ø3.5 ø0.031 to ø0.138 approx. ø0.5 ø0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW FX-100
series
10 ø0.125 ø0.005 FD-R33EG, FD-EG31
light lens
Parallel

0.394 ø0.175 ø0.007 FD-R34EG


ø4.0 ø0.157 approx. 0 to 30 FX-MR9
0 to 1.181 ø5 ø0.197
ø0.25 ø0.010 FD-R32EG, FD-EG30
INDEX
ø0.5 ø0.020 FD-R31G, FD-32G, FD-32GX, FD-42G, FD-42GW
44

New product FIBER OPTIONS


introduction
Tough
Fiber Model No. when ordering heat-resistant fibers individually as replacement parts
• FT-H20-J20 (one pair set) • FT-H20-J30 (one pair set) • FT-H20-J50 (one pair set)

Fiber
• FT-H20-VJ50 (one pair set) • FT-H20-VJ80 (one pair set)
Selection
Guide
Model No. when ordering vacuum-resistant fibers individually as replacement parts
Model
Choose
• Vacuum-resistant fiber • Photo-terminal • Mouting bracket for FD-H30-KZ1V(-S)
by shape/ FT-H30-M1V (one pair set) FV-BR1 (one pair set) MS-FD-2
application
FD-H30-KZ1V
How to read
FD-H30-L32V • Fiber at atmospheric side
Model No
FT-J8 (one pair set)
Earlier models
comparison
table

Model No. when ordering accessories additionally • RF-003 • RF-13 • FX-CT2 • FX-CT3
Fibers • RF-003 (FR-KZ50E/KZ50H exclusive reflector)
Super • RF-13 (FR-Z50HW reflective tape)
Quality • FX-CT2 (Fiber cutter)
Threaded • FX-CT3 (FD-H40Y/F41Y fiber cutter)
Type • FX-AT2 • FX-AT3 • FX-AT4 • FX-AT5 • FX-AT6
• FX-AT2 (Attachment for fixed-length fiber, Orange)
Square Head
Type • FX-AT3 (Attachment for ø2.2 mm ø0.087 in fiber, Clear orange)
Cylindrical • FX-AT4 (Attachment for ø1 mm ø0.039 in fiber, Black)
Type • FX-AT5 (Attachment for ø1.3 mm ø0.051 in fiber, Gray)
Sleeve

Flat
( mixed fiber, Black / Gray
• FX-AT6 Attachment for ø1 mm ø0.039 in / ø1.3 mm ø0.051 in
) • MS-FD-2

Type • MS-FD-2 (Fiber mounting bracket)


Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
45

FIBER OPTIONS New product


introduction
Tough
Others Protective tube Fiber

• FTP-□
Designation Model No. Description
• FDP-□ Fiber
Selection
Guide
FTP-500 (0.5 m 1.640 ft)
FT-42 FT-43
For M4 Model
FTP-1000 (1 m 3.281 ft) FT-42S FT-H13-FM2
thread
FT-42W Choose
Protective tube FTP-1500 (1.5 m 4.921 ft) by shape/
for thru-beam Fiber bender application

type fiber FTP-N500 (0.5 m 1.640 ft) How to read


FT-31 FD-31 • FB-1 Model No.
For M3
FTP-N1000 (1 m 3.281 ft) FT-31S FD-31W

Applicable fibers
Earlier models
thread The protective comparison
FT-31W tube, made of non- table
FTP-N1500 (1.5 m 4.921 ft) corrosive stainless
steel, protects the
FDP-500 (0.5 m 1.640 ft) FD-61 FD-62
inner fiber cable from
For M6 FD-61G FD-H13-FM2 any external forces.
FDP-1000 (1 m 3.281 ft) thread FD-61S Fibers
Protective tube FDP-1500 (1.5 m 4.921 ft) FD-61W Super
for reflective Universal sensor mounting stand Quality
type fiber FDP-N500 (0.5 m 1.640 ft) Using the arm which enables adjustment in Threaded
For M4 FD-41 FD-41S the horizontal direction, sensing can also be Type
FDP-N1000 (1 m 3.281 ft) thread FD-41W FD-41SW done from above an assembly line. Square Head
FDP-N1500 (1.5 m 4.921 ft) • MS-AJ1-F Type

360° rotation Cylindrical


The fiber bender bends the sleeve part of the fiber head at the proper Type
Fiber bender FB-1 radius. (Note 1)
Forward / back Sleeve
Universal sensor MS-AJ1-F Horizontal mounting type
Mounting stand assembly for fiber (For M3,
adjustment:
mounting stand 130 mm Height Flat
M4 or M6 threaded head fiber) 5.118 in approx. adjustment: Type
(Note 2) MS-AJ2-F Vertical mounting type
150 mm 5.906 in Small
Liquid inflow approx. Spot
This joint suppresses false operations
prevention 360° Mounting hole
joint
MS-FX-01Y due to liquid slip-in from the top of the rotation 20° for M6 screw Narrow
protective tube. 20° Beam
Applicable fibers

(Note 2) Angle adjustment: ±20° Wide


Protective tube Beam
extension joint MS-FX-02Y FD-HF40Y The protective tube can be extended. Convergent
(Note 2)
FD-F41Y Reflective
• MS-AJ2-F Type
360° rotation Retroreflective
Fiber The joint is used for mounting fibers on a Type
mounting joint MS-FX-03Y Chemical / Oil-
tank. Forward / back
(Note 2) adjustment: resistant
Height
The incident light intensity may vary when using a multi-core fiber or a 130 mm
adjustment: Heat-
Single core 5.118 in approx. resistant
FX-AT15A thin type sharp bending fiber. This holder suppresses the variation in 150 mm 5.906 in
holder the incident light intensity. (Brown) approx. Vacuum-
360° resistant
20° Mounting hole
rotation
RF-210 20° for M6 screw Liquid Leak /
Used with FR-Z50HW. Angle adjustment: ±20° Liquid Detection
Reflector RF-220 Refer to p.27 or p.38 for the sensing range of FR-Z50HW to be used
in combination.
RF-230 Single core holder Fiber
Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber. Options
2) The joint internal ferrule (MS-FX-YF) is available as a spare part. A distorted ferrule may result in leakage. • FX-AT15A

Liquid inflow prevention joint Protective tube extension joint Fiber mounting joint Semi-custom
MS-FX-01Y MS-FX-02Y MS-FX-03Y fibers
• MS-FX-01Y • MS-FX-02Y • MS-FX-03Y
MS-FX-01Y MS-FX-02Y MS-FX-03Y
MS-FX-01Y MS-FX-02Y MS-FX-03Y
Body Union nut Union nut
Ferrule (MS-FX-YF) Ferrule (MS-FX-YF)
Fiber
Body Union nut Ferrule (MS-FX-YF)
Union nut Dimensions
Union nut Body Union nut Union nut
Ferrule (MS-FX-YF) Ferrule (MS-FX-YF) Thru-beam
Ferrule (MS-FX-YF) Ferrule (MS-FX-YF) Ferrule
Body(MS-FX-YF)
Union nut Type
Ferrule (MS-FX-YF)
Union nut Body Body Retroreflective
Ferrule (MS-FX-YF) Body Type
Body
Union
Ferrule nut
(MS-FX-YF)Body Reflective
Ferrule (MS-FX-YF) Type
Union nut
Union nut Others
Reflector
• RF-210 • RF-220 • RF-230 8.3 mm
11 mm 8.3 mm
33.3 mm 35.3 mm 50.3 mm
Amplifiers
12.8
mm FX-500
series
42.3 FX-100
mm
series
59.3
mm

INDEX
46

New product Semi-custom fibers that flexibly meet diverse needs


introduction
Tough Guide to interchanging fiber length and sleeve length
Fiber
Custom-ordered products are available with different fiber lengths and sleeve lengths in order to respond quickly to different
requirements.
Fiber Contact us more in formation.
Selection
Guide

Model
Fiber length change Sleeve length change
Choose It is possible to extend up to 30 m 98.425 ft Extension is possible up to 120 mm 4.724 in
by shape/
application in units of 1 m 3.281 ft, varying depending on in units of 10 mm 0.394 in. Applicable models
How to read the model. Refer to the table on the next page are sleeve extension-type models indicated by
Model No for applicable models. in the table on the next page.
Earlier models
comparison
table

Fibers
Fiber cable length L
Super
Quality
Threaded
Type
Sleeve length ℓ
Square Head
Type
Note that the model number differs from
Cylindrical previous models with changed lengths.
Type Note that the model number differs from
previous models with changed lengths.
Sleeve

Flat
Type • Attenuation ratio characteristics for fiber cable length and sensing range
Small
Spot Note that the longer the fiber cable length, the shorter the sensing range.
Narrow
Beam
Typical example: ‌Bending radius R4 mm/R2 mm Typical example: ‌Bending radius R1 mm
Wide
Beam (Tough fiber) (Sharp bending fiber FT- □W/FD- □W)
Convergent
Reflective 1.0 1.0
Type
Retroreflective
Type 0.9 0.9
Chemical / Oil- Bending radius R4 mm R0.157 in
resistant 0.8 0.8
Beam axis diameterφ1 mm φ0.039 in
Sensing range coefficient

Sensing range coefficient

Heat-
resistant 0.7 0.7
Vacuum- Bending radius R1 mm 0.0395 in
resistant 0.6 0.6
Beam axis diameterφ1 mm φ0.039 in
Liquid Leak /
Liquid Detection 0.5 0.5

0.4 0.4

Fiber 0.3 Bending radius R2 mm R0.079 in 0.3


Options Beam axis diameterφ0.5 mm φ0.020 in
0.2 0.2

0.1 0.1 Bending radius R1 mm 0.0395 in


Semi-custom Beam axis diameterφ0.5 mm φ0.020 in
fibers
0 0
2 10 20 30 2 10 20 30
6.562 32.808 65.617 98.425 6.562 32.808 65.617 98.425
Fiber cable length L (m ft) Fiber cable length L (m ft)
Fiber
Dimensions
Thru-beam
Type Note: Because infrared types are easily affected by humidity, please ask assistance when using them in a humid environment or in an
Retroreflective
environment with varying humidity.
Type
Reflective
Type Extended protective tube
Others The chemical-resistant cover and stainless jacket can be extended in accordance with the fiber cable length.
Applicable models are indicated in the table as follows.
: Models which can have extended protective tube (fluorine resin)
: Models which can have extended stainless jacket sheath
Amplifiers
FX-500
series
FX-100 Protective tube
Fiber
series

INDEX
47

New product
introduction
Tough
Fiber

Applicable models
Thru-beam type Reflective type
Fiber
Applicable Applicable Selection
Basic specifications Basic specifications Guide
fiber length fiber length
Fiber cable Protective Sensing range Fiber cable Protective Sensing range Model
Sleeve Max. Unit Sleeve Max. Unit
length tube (mm) length tube (mm)
Model No. length (m) (m) Model No. length Choose
: extension FX-500 series : extension FX-500 series (m) (m) by shape/
(mm) (mm)
Free-cut length (STD)(Note 1) Free-cut length (STD)(Note 1) application
 FT-140 10 m 19,600 (Note 2) 30 1  FD-31 2m 125 30 1 How to read
 FT-31 2m 315 30 1  FD-31W 2m 80 20 1 Model No.
FT-31S 2m 40 (Note 3) 315 30 1  FD-32G 2m 200 30 1 Earlier models
comparison
 FT-31W 2m 260 20 1 FD-32GX 1m 300 mm (Note 4) 200 30 1 table
 FT-42 2m 1,130 30 1  FD-41 2m 125 30 1
FT-42S 2m 40 (Note 3) 1,130 30 1 FD-41S 2m 40 (Note 3) 125 30 1
 FT-42W 2m 800 30 1 FD-41SW 2m 40 (Note 3) 80 20 1
 FT-43 2m 1,400 30 1  FD-41W 2m 270 20 1 Fibers
 FT-45X 1m 1,200 10 0.5  FD-42G 2m 200 30 1
 FT-A11 2m 3,600 (Note 2) 10 1  FD-42GW 2m 150 20 1 Super
 FT-A11W 2m 3,600 (Note 2) 10 1  FD-61 2m 450 30 1 Quality
 FT-A32 2m 3,600 (Note 2) 10 1  FD-61G 2m 420 30 1 Threaded
 FT-A32W 2m 3,600 (Note 2) 10 1 FD-61S 2m 40 (Note 3) 420 30 1 Type
 FT-AL05 2m 860 20 1  FD-61W 2m 270 30 1 Square Head
 FT-E13 1m 5 15 10 0.5  FD-62 2m 520 30 1 Type
 FT-E23 1m 5 75 10 0.5  FD-64X 1m 280 10 0.5 Cylindrical
FT-F93 2m 1 m (Note 4) 30 1  FD-A16 2m 200 30 1 Type
 FT-H13-FM2 2m 700 30 1  FD-AL11 2m 320 20 1
 FT-H20-J50-S 500 mm (Note 5) 470 6.5 0.1 Sleeve
 FD-E13 1m 3 12 3 0.1
 FT-H20-M1 1m 540 6.5 0.1
 FD-E23 1m 5 55 3 0.1 Flat
  FT-H20-VJ80-S 800 mm (Note 5) 600 6.5 0.1
 FD-EG30 500 mm 48 3 0.1 Type
 FT-H20W-M1 1m 470 6.5 0.1
 FD-EG30S 1m 15 50 3 0.1 Small
 FT-H30-M1V-S 1m 270 6.5 0.1
 FD-EG31 500 mm 20 3 0.1 Spot
 FT-H35-M2 2m 430 6.5 0.1
 FT-H35-M2S6 2m 430 6.5 0.1  FD-F4 2m 10 1 Narrow
FT-HL80Y 2m (Note 6) 1.5 m (Note 4) 3,600 (Note 2) 30 1  FD-F41 2m 10 1 Beam
 FT-KS40 2m 3,600 (Note 2) 10 1 FD-F71 5m 3 m (Note 4) 20 1
Wide
 FT-KV26 2m 710 10 1  FD-FA93 2m 10 1 Beam
 FT-KV40 2m 3,600 (Note 2) 10 1  FD-H13-FM2 2m 350 30 1 Convergent
 FT-KV40W 2m 3,600 (Note 2) 10 1  FD-H18-L31 2m 16 5 1 Reflective
Type
FT-L80Y 2m (Note 6) 1.5 m (Note 4) 3,600 (Note 2) 30 1  FD-H20-21 1m 230 6.5 0.1
 FD-H20-M1 1m 330 6.5 0.1 Retroreflective
 FT-R31 2m 270 30 1 Type
 FT-R43 2m 720 30 1  FD-H25-L43 3m 1.5 to 26 6.5 0.1
 FD-H25-L45 3m 5 to 42 6.5 0.1 Chemical / Oil-
 FT-R40 2m 930 30 1 resistant
 FT-R41W 2m 800 30 1   FD-H30-KZ1V-S 1m 20 to 200 6.5 0.1
 FD-H30-L32 2m 17 5 1 Heat-
 FT-R42W 2m 2,200 30 1 resistant
 FT-R44Y 2m 720 30 1   FD-H30-L32V-S 3m 8 6.5 0.1
 FT-R60Y 2m 2,100 30 1  FD-H35-20S 1m 260 6.5 0.1 Vacuum-
resistant
 FT-S11 500 mm 90 30 1  FD-H35-M2 2m 260 6.5 0.1
 FT-S21 2m 315 30 1  FD-H35-M2S6 2m 260 6.5 0.1 Liquid Leak /
 FT-S21W 2m 260 20 1  FD-L10 2m 0 to 5 5 1 Liquid Detection
 FT-S31W 2m 800 30 1  FD-L11 2m 0 to 9.5 5 1
 FT-S32 2m 3,100 30 1  FD-L12W 1m 8 5 1
 FT-V23 2m 20 450 30 1  FD-L20H 2m 30 5 1
 FT-V24W 2m 15 110 10 1  FD-L21 2m 1.5 to 16 5 1 Fiber
 FT-V25 2m 15 240 30 1 Options
 FD-L21W 2m 3 to 14 5 1
 FT-V30 2m 20 680 30 1  FD-L22A 2m 0 to 24 5 1
 FT-V40 2m 3,500 30 1  FD-L23 3m 0 to 29 5 1
FT-V80Y 2m (Note 6) 1.5 m (Note 4) 3,600 (Note 2) 30 1  FD-L30A 3m 0 to 43 5 1
 FT-Z20HBW 1m 260 20 1 Semi-custom
 FD-L31A 3m 4 to 33 5 1 fibers
 FT-Z20W 1m 620 20 1  FD-L32H 4m 0 to 56 5 1
 FT-Z30 2m 2,100 30 1  FD-R31G 2m 170 30 1
 FT-Z30E 2m 3,500 30 1  FD-R32EG 500 mm 45 3 0.1
 FT-Z30EW 2m 3,400 20 1  FD-R33EG 500 mm 19 3 0.1
 FT-Z30H 2m 3,500 30 1 Fiber
 FD-R34EG 500 mm 38 3 0.1 Dimensions
 FT-Z30HW 2m 3,500 20 1  FD-R41 2m 210 30 1
 FT-Z30W 2m 1,500 20 1 Thru-beam
 FD-R60 2m 290 30 1 Type
 FT-Z40HBW 2m 800 20 1  FD-R61Y 2m 280 30 1
 FT-Z40W 2m 1,500 20 1 Retroreflective
 FD-S21 1m 80 20 1 Type
 FT-Z802Y 2m 3,100 30 1
 FD-S31 2m 125 30 1
Reflective
Retroreflective type  FD-S32 2m 420 30 1 Type
 FD-S32W 2m 270 20 1
Applicable
Basic specifications  FD-S33GW 2m 150 20 1 Others
fiber length
 FD-S60Y 2m (Note 6) 1.5 m (Note 4) 320 30 1
Fiber cable Protective Sensing range
Sleeve Max. Unit  FD-V30 2m 15 65 30 1
length tube (mm)
Model No. length (m) (m)  FD-V30W 2m 15 20 10 1
: extension FX-500 series
(mm)  FD-V50 2m 20 120 30 1
Free-cut length (STD)(Note 1)
 FR-KZ22E 2m 15 to 310 10 1  FD-Z20HBW 1m 2 to 85 20 1 Amplifiers
 FR-KZ50E 2m 20 to 300 10 1  FD-Z20W 1m 1 to 65 20 1
FX-500
 FR-KZ50H 2m 20 to 300 10 1  FD-Z40HBW 2m 260 20 1 series
 FR-Z50HW 2m 100 to 990 30 1  FD-Z40W 2m 190 20 1
 FD-Z50HW 2m 10 to 650 30 1 FX-100
: Models which can have extended sleeve series
: Models which can have extended protective tube (fluorine resin)
: Models which can have extended stainless jacket sheath
Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range.
3) Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in. INDEX
4) Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft. (however, FD-32GX is in units of 0.1 m 0.328 ft.)
5) Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut).
6) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.
48
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Thru-beam type fibers and reflective type, and in alphabetic order of the Model No.

FT-140 Free-cut FT-30


Fiber <with FX-AT3> <with FX-AT2>
Selection
Guide ø23 ø0.906 ø10 ø0.394 Lens (PMMA) 2 2,000
19 0.748 ø6.5 10 78.740
Model
ø0.256 0.079
17 1.8 Resin plug(ABS) (19.7)
ø10 23 0.906 10,000 393.701 0.394 (0.776) 10.2
ø0.394 0.669 2.7 0.071
Choose 8 8 0.106 ø2 ø1 (ø4.33)(ø0.170) 0.402
by shape/ 3.5 (20) (0.3)
application 0.138 0.315 0.315 ø2.2 ø0.087 ø0.079 (0.787) ø0.039
(30) (0.012)
How to read (1.181)
Model No
(ø3.2)(ø0.126) Model No. tube (m-PPE) ø2.2 ø1.8
ø3 ø0.118 -0.10 -0.004
Earlier models ø4.5
comparison M14 × 1 0.039 ø0.177 ø1 ø0.039 fiber core × 1 (PMMA) -0.13 -0.005 (ø2) (ø0.079) Model No. tube (m-PPE) ø0.087 ø0.071
table Mounting reference surface (Screw periphery)
Holder (ABS)
ø7 ø0.276 Sheath ø2.2 ø0.087 (Polyethylene) Toothed lock washer M3 [Brass (Nickel plated)]
Protector (PVC) End bracket [Brass (Nickel plated)]
Toothed lock washer M14 Opposing faces 5.5 0.217 thickness 1.8 0.071 [Brass (Nickel plated)]
[Iron (Chromed)] Hexagon nut M14 M3 × 0.5 0.020
[Brass (Nickel plated)]
Fibers
Super
Quality FT-31 Free-cut FT-31S Free-cut
Threaded <with FX-AT4> <with FX-AT4>
Type 2
0.079 ø6.5 40 1.575 10 2,000 78.740
Square Head ø6.5 10 2,000 ø0.256 0.394
0.394 78.740 5.5
Type ø0.256 1.8 0.217 5
ø2 0.071 ø1 2.7 Allowable 0.197 1.8 0.071
Cylindrical 2.7 (30)
0.106 ø0.079 ø0.039 0.106 10 bending 10 (30) ø1 ø0.039
Type (1.181) 0.394 range 0.394 (1.181)

Sleeve ø0.88
ø0.5 ø0.020 fiber core × 1 (Acrylic) ø0.035 ø2 ø0.079 (ø2)(ø0.079) Model No. tube (m-PPE)
Sleeve
Sheath ø1 ø0.039 (Polyethylene)
Flat ø3 ø0.118 -0.10 -0.004 [Stainless steel (SUS304)] M3 × 0.5 0.020 ø0.5 ø0.020 fiber core × 1 (PMMA)
Type -0.13 -0.005 (ø2) (ø0.079) Model No. tube (m-PPE) Sheath ø1 ø0.039 (Polyethylene)
Mounting reference surface (Screw periphery) End bracket [Stainless steel (SUS303)]
Toothed lock washer M3 [Stainless steel (SUS304)] Hexagon nut M3
Small End bracket [Stainless steel (SUS303)] Toothed lock washer M3 [Stainless steel (SUS304)] [Stainless steel (SUS304)]
Spot Opposing faces 5.5 0.217 thickness 1.8 0.071 [Stainless steel (SUS304)]
M3 × 0.5 0.020
Narrow
Beam
Wide FT-31W Free-cut FT-40
Beam
Convergent <with FX-AT4> <with FX-AT2>
Reflective
Type ø6.5 10 2,000
2 2,000 78.740 12
Retroreflective
ø0.256 0.394 ø8.5 3 0.118 78.740
5.5 0.079 0.472 (19.7)
Type
1.8 0.071
ø1 ø0.335 2.4 0.094 Resin plug (ABS) (0.776) 10.2
0.217 3.5
2.7 (30)(1.181) ø0.039 1 (ø4.33) 0.402
Chemical / Oil- 0.106 0.138 ø2 0.039 (20) ø2.2 (ø0.170)
resistant ø0.079 (0.787) ø0.087 (0.3)
(0.012)
Heat- -0.1 -0.004 (ø2)(ø0.079)Model No. tube(m-PPE)
ø3 ø0.118 -0.13 -0.005
resistant ø0.5 ø0.020 fiber core × 1 (PMMA)
Mounting reference surface ø2.2 ø1.8
Vacuum- (Screw periphery)
Sheath ø1 ø0.039 (Polyethylene) ø4 ø0.157 -0.10 -0.004 (ø3.2) (ø0.126) Model No. tube (m-PPE) ø0.087 ø0.071
ø2 ø0.079 -0.13 -0.005
resistant End bracket [Stainless steel(SUS303)] Mounting reference surface (Screw periphery) FT-31S Toothed lock washer M4 [Brass (Nickel plated)]
M3 × 0.5 0.020 End bracket [Brass (Nickel plated)]
Liquid Leak / Hexagon nut M3 Opposing faces 7 0.276 thickness 2.4 0.094 [Brass (Nickel plated)]
Toothed lock washer M3 [Stainless steel(SUS304)]
Liquid Detection [Stainless steel(SUS304)] M2.6 × 0.45 0.018 M4 × 0.7 0.028

Fiber FT-42 Free-cut FT-42S Free-cut


Options
<with FX-AT3> <with FX-AT3>
3
ø8.5 FT-140 0.118 12 2,000 ø8.5
ø0.335 0.472 78.740 ø0.335 12 2,000 78.740
40 1.575
1 0.039 2.4 0.094 7 0.472
Semi-custom ø2 ø2.2 0.276 5
3.5 0.138
fibers ø0.079 (30) ø0.087 3.5
Allowable 0.197 2.4 (30) ø2.2
(1.181) 0.138
10 bending 10
0.094 ø0.087
0.394 range 0.394 (1.181)

ø1 ø0.039 fiber core × 1 (Acrylic)


Sheath ø2.2 ø0.087 (Polyethylene) ø1.48 ø0.058 ø2.5 ø0.098
Fiber ø4 ø0.157 -0.1 0.004 (ø3.2)(ø0.126) Model No. tube (m-PPE)
-0.13 0.005 (ø3.2) (ø0.126) Model No. tube (m-PPE) Sleeve [Stainless steel (SUS304)] M4 × 0.7 0.028 ø1 ø0.039 fiber core × 1 (PMMA)
Dimensions Mounting reference surface (Screw periphery) Toothed lock washer M4 [Stainless steel (SUS304)] Sheath ø2.2 ø0.087 (Polyethylene)
Toothed lock washer M4 [Stainless steel(SUS304)]
Thru-beam End bracket [Stainless steel(SUS303)] Hexagon nut M4 End bracket [Stainless steel (SUS303)]
Type Opposing faces 7 0.276 thickness 2.4 0.094 [Stainless steel(SUS304)] [Stainless steel (SUS304)]
M2.6 × 0.45 0.018
Retroreflective M4 × 0.7 0.028
Type
Reflective
Type FT-42W Free-cut FT-43 Free-cut
Others <with FX-AT3> <with FX-AT3>
ø8.5 3 12 ø8.5
ø0.335 0.472 2,000 78.740 ø0.335 3 12 2,000 78.740
7 0.276 0.118 2.4 7 0.276 0.118 0.472
3.5 0.138 1 0.094 (30) ø2.2 ø0.087 ø2.2
0.039 3.5 0.138 1 2.4 (30)
(1.181) 0.039 0.094 ø0.087
(1.181)
Amplifiers
ø2 (ø3.2)(ø0.126) Model No. tube (m-PPE) ø2 (ø3.2)(ø0.126) Model No. tube (m-PPE)
FX-500 -0.1 -0.004
ø4 ø0.157 -0.13 -0.005 ø0.079
-0.1 -0.004
ø4 ø0.157 -0.13 -0.005
ø1 ø0.039 fiber core × 1 (PMMA) ø0.079
series ø1.5 ø0.059 fiber core × 1 (PMMA)
Mounting reference surface Sheath ø2.2 ø0.087 (Polyethylene) Mounting reference surface Sheath ø2.2 ø0.087 (Polyethylene)
FX-100 (Screw periphery) M2.6 × 0.45FT-31W0.018 End bracket [Stainless steel (SUS303)]
(Screw periphery)
M4 × End bracket [Stainless steel (SUS303)]
series M4 × 0.75 0.030 M2.6 × 0.45 0.018 0.7 0.028
Hexagon nut M4 Hexagon nut M4
[Stainless steel (SUS304)] Toothed lock washer M4 [Stainless steel (SUS304)] [Stainless steel (SUS304)]
Toothed lock washer M4 [Stainless steel (SUS304)]

INDEX
49
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Thru-beam type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FT-45X FT-A11 Free-cut


<with FX-AT5> Fiber
<with FX-AT2> Selection
20 0.787 Guide
1,000 39.370 Center of beam axis Lens (Norbornene resin)
3 0.118 12 8
7 1 0.039 0.472 (2.5)(0.098) 19.7 0.776 0.315
Sensing face (2.2 × 11) (0.087 × 0.433) Model
0.276 2.4 0.094 ø2.6 ø0.102 (ø4.33)(ø0.170)
(30) 10.2 Choose
M2.6 × 0.45 0.018 (1.181) by shape/
0.402 4 0.157
27 1.063 2,000 78.740 application
ø8.5 ø2 ø0.079
ø2.2 ø0.087
4.2
(8)
Beam axis 4 0.157 ø1.3 How to read
ø0.335 (ø4)(ø0.157) 0.165 5.2 0.205 Model No.
M4 × 0.7 0.028 Model No. tube (m-PPE) Resin plug (ABS) (0.315) ø0.051
Details of Toothed lock washer M4 Earlier models
sensing part [Stainless steel (SUS304)] Protective tube (13.5) 9.5 0.374 comparison
Polyolefin tube included (0.531) ø0.75 ø0.030 fiber core × 1 (PMMA) table
3.5 0.138 Hexagon nut M4 SUS304 spiral tube Sheath ø1.3 ø0.051 (Polyethylene)
[Stainless steel (SUS304)] End bracket

57
Crimping part

.1
[Stainless steel 2-ø3.2 ø0.126 ø6.0 ø0.236 countersinking (on both sides)

R0
(SUS303)]

R4
19 Enclosure (PC)
ø1 ø0.039 fiber core × 1 (PMMA) 4

2-
0.157 0.748 Fibers
FT-A11W Free-cut FT-A32 Free-cut Super
Quality
<with FX-AT5> <with FX-AT5>
Threaded
8 Center of beam axis 19 0.748
Center of beam axis ø0.75 ø0.030 fiber core × 1 (PMMA) Type
Sheath ø1.3 ø0.051 (Polyethylene)
0.315 Square Head
Lens (Norbornene resin) Type
Sensing face (2.2 × 11) (0.087 × 0.433) 4 0.157
27 1.063 2,000 78.740 Sensing face (3.2 × 32)(0.126 × 1.260) Lens (Norbornene resin) Cylindrical
Beam axis 4 0.157 4 0.157 Type
4.2 0.165 (8)(0.315) 5.2 0.205 5 65 2.559 2,000 78.740
ø1.3 ø0.051 0.197 Beam axis Enclosure (PC)
(19) 5.2 0.205
Sleeve
(13.5) 9.5 (0.748) ø1.3
(0.531) 0.374 ø1 ø0.039 fiber core × 1 (PMMA) 7.3 0.287
ø0.051
Sheath ø1.3 ø0.051 (Polyethylene) 16 Flat
57

(20) 0.630 Type


0.1

2-ø3.2 ø0.126 ø6.0 ø0.236


4R

countersinking (on both sides) (0.787) Small


4 19 0.748
2-R

0.157 Enclosure (PC)


2-ø3.2 ø0.126 ø6 ø0.236 Spot
157 12 45 1.772 countersinking (on both sides)
4 R0. 0.472 Narrow
2-R
Beam
Wide
FT-A32W Free-cut FT-AL05 Free-cut Beam
<with FX-AT5> <with FX-AT3> Convergent
Reflective
FT-45X
Type
Center of beam axis 15 0.591 2,000 78.740
19 0.748 8 Retroreflective
5 0.197 2.5 0.098
0.315 Type
ø1 ø0.039 fiber core × 1 (PMMA) Head block
2-M3 × 0.5 0.020 ø2.2
Sensing face (3.2 × 32) (0.126 × 1.260) Sheath ø1.3 ø0.051 (Polyethylene) (LCP) 15 10 0.394 ø0.087
Chemical / Oil-
Lens (Norbornene resin) 0.591 resistant
5 65 2.559 4 0.157 4.5 0.177
2,000 78.740 Heat-
0.197 Beam Enclosure (PC) 5.2
(19)
axis 0.205 Details of 2.5 0.098 4.5 resistant
(0.748) ø1.3 0.177 ø0.25 ø0.010 fiber core × 16 (PMMA)
ø0.051 sensing part 1 0.039 Sheath ø2.2 ø0.087 (Polyethylene) Vacuum-
16 7.3 0.287 Enclosure (PPS) resistant
(20) 0.630
(0.787) 5.25 0.207
Liquid Leak /
2-ø3.2 ø0.126 ø6 ø0.236 Liquid Detection
.157 countersinking (on both sides)
4 R0 12 45 1.772 FT-A11
2-R 0.472 FT-A11W Sensing part (ø0.25 fiber core ø0.010 × 16)

Fiber
Options
FT-E13 Free-cut FT-E23 Free-cut

1,000
<with FX-AT4> <with FX-AT4>
15 39.370 1,000
0.591 ø1 15 Semi-custom
0.591 39.370 ø1
fibers
5±0.5 (30) ø0.039 5±0.5 (30) ø0.039
0.197±0.020 (1.181) 0.197±0.020 (1.181)

Sleeve [Stainless steel (SUS304)] Sleeve [StainlessFT-A32


steel (SUS304)]
ø0.5 ø0.020 ø0.5 ø0.020 × 1 fiber core (PMMA) Fiber
End bracket [Stainless steel (SUS303)] End bracket [Stainless steel (SUS303)] Sheath ø1 ø0.039 (Polyethylene)
fiber core × 1 (PMMA) Dimensions
Sheath ø1 ø0.039 (Polyethylene)
Details of ø3 ø0.118 0 0 Details of 0 0
ø3 ø0.118 -0.1 -0.004 (ø2) (ø0.079) Model No. tube (m-PPE)
-0.1 -0.004 Thru-beam
sensing part Mounting reference surface (Periphery) (ø2) (ø0.079) Model No. tube (m-PPE) sensing part Mounting reference surface (Periphery) Type
ø0.125 ø0.005 fiber core × 1 (PMMA) ø0.25 ø0.010 fiber core ×1 (PMMA) Retroreflective
Type
Reflective
Type
ø0.25 ø0.010 0 0 0 0
ø0.4 ø0.016 -0.1 -0.004
-0.1 -0.004
Others

FT-F93 Free-cut FT-H13-FM2 Free-cut


<with FX-AT4> <with FX-AT3>
20 0.787 2,000 78.740 3 13 2,000 Amplifiers
12 1,000 Beam-emitting side 3.5 0.118 78.740
2-ø1 ø0.039 0.138 0.512
0.472 39.370 (Gray) 12 FX-500
0.472 series
7.2 0.283
Beam-receiving side FX-100
23
0.906 10.3 0.406 6 0.236 (Black) ø3 series
Enclosure ø0.25 ø0.010 × 4 fiber core (PMMA) ø0.118 ø2.2 ø0.087
ø1.5 ø0.059
5.5 0.217 (ABS) Sheath ø1 ø0.039 (Polyethylene) fiber core × 1 (Fluorine resin)
M4 × 0.7 0.028
ø3.1 ø0.122 Protective tube [PFA(Fluorine resin)] Opposing faces 7 0.276, thickness 2.4 0.094
6 0.236 Screw tightening face
ø3.1 ø0.122 Toothed lock washer ø8.5 ø0.335
FT-A32W
17 9 0.354
INDEX
0.669
50
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Thru-beam type fibers and reflective type, and in alphabetic order of the Model No.

FT-H20-J20-S  FT-H20-J30-S  FT-H20-J50-S Free-cut (Note) FT-H20-VJ50-S  FT-H20-VJ80-S Free-cut (Note)


Fiber
Selection <with FX-AT3> <with FX-AT3>
Guide
Heat-resistant side unit diagram (side view) Heat-resistant side unit diagram (side view)
Model 23 0.906 A 24
12 Joint bracket A Joint bracket
Choose 3 0.118 0.945
by shape/ 0.472 [Brass (nickel plated)] Heat & cold-resistant Ordinary temperature [Brass (nickel plated)]
application 2.5 0.098 Heat & cold-resistant Ordinary temperature specifications specifications
specifications specifications
How to read 9.3
M2.6 × 0.45 0.018 ø4 ø0.157 (100) (3.937) 0.366 Beam axis ø4 9.3
Model No (100) (3.937)
ø0.157 0.366
Earlier models
comparison
table M4 × 0.7 0.028 Opposing faces7 0.276, 5.4 ø3.5 ø0.138 ø3.8 ø0.150
End bracket thickness 2.4 0.094 5.4 ø3.5 ø0.138
[Brass (nickel plated)] 0.213 Lock nut (polycarbonate)
Toothed lock washer ø2.7 ø0.106 Liner + braid tube 0.213 Lock nut (polycarbonate)
ø8.5 ø0.335 ø2.7 ø0.106 Liner + braid tube [Stainless steel (SUS)] [stainless steel (SUS304)]

Fibers Ordinary temperature side fiber (FT-42) connection diagram (front view) Ordinary temperature side fiber (FT-42) connection diagram (front view)
B (25.8) (1.016) 2,000 78.740
Super 17 24 0.945 B (25.8) (1.016) 2,000 78.740
Quality 0.669 30 12 17 30
ø2.2 8 0.315 0.472
1.181 0.669 1.181 ø2.2
Threaded 6 0.236 ø0.087 2.2 0.087 Set screw 6 0.236 M4 × 0.7 0.028 ø0.087
Type tightening range
Square Head
Type (ø3.2) (ø0.126)
Spring washer [Stainless steel (SUS)] Model No. tube (m-PPE) Head [Brass (Nickel plated)] (ø3.2) (ø0.126)
Cylindrical M4 × 0.7 0.028 Prism (BK7) Spring washer [Stainless steel (SUS)] Model No. tube (m-PPE)
Type Opposing faces 7 0.276,
thickness 3.2 0.126 ø1 ø0.039 fiber core × 1 (Acrylic) Opposing faces 7 0.276,
(Polypropylene) Outer sheath ø2.2 ø0.087 (Polyethylene) Holder thickness 3.2 0.126 ø1 ø0.039 fiber core × 1 (Acrylic)
Sleeve [Brass (Nickel plated)] (Polypropylene) Outer sheath ø2.2 ø0.087 (Polyethylene)

Flat
Type Model No. A B
Model No. A B
Small FT-H20-J20-S 200 +25
0 7.874 +0.984
0 185 +30
0 7.284 +1.181
0
Spot
FT-H20-VJ50-S 500 +25
0 19.685 +0.984
0 485 +30
0 19.095 +1.181
0
Narrow FT-H20-J30-S 300 +25
0 11.811 +0.984
0 285 +30
0 11.221 +1.181
0 +55
Beam FT-H20-VJ80-S 800 +50
0 31.496 +1.969
0 785 0 30.906 +2.165
0
Wide FT-H20-J50-S 500 +25
0 19.685 +0.984
0 485 +30 +1.181
0 19.095 0
Beam Note: Ordinary temperature side fiber (FT-42) only.
Convergent Note: Ordinary temperature side fiber (FT-42) only.
Reflective
Type
Retroreflective FT-H20-M1 FT-H20W-M1
Type <with FX-AT2>
3 0.118 20
Chemical / Oil- 0.787 1,000 39.370
Heat & cold-resistant Ordinary temperature 3 20
resistant specifications specifications 0.118 0.787
1,000 39.370

Heat- 3.5 150 16.7 18.3


Heat & cold-resistant Ordinary temperature
0.138 12 specifications specifications
resistant 0.472 5.906 0.657 0.720 150
3.5 ø2.5 19.5
Screw tightening face ø1.6 5.906 0.768
Vacuum- 0.138 ø0.098 ø0.063 10
resistant ø2.2
ø2.9 ø0.114 (Silicone) ø0.087
0.394
ø1.1 ø0.043 fiber
Liquid Leak / core bundle × 1 ø4 ø0.157 [Brass (Nickel plated)] ø2.2
Liquid Detection Toothed lock ø0.087
Screw tightening face ø5 ø0.197 Fixing bracket [Brass (nickel plated)] Fixing plug (PA) M2.6 × 0.45 0.018 washer ø8.5 ø0.335 ø4.33 ø0.170 (PA)
M2.6 × 0.45 0.018 Opposing faces 7 0.276, thickness 2.4 0.094 ø0.8 ø0.031 fiber M4 × 0.7 0.028 Protective tube (PTFE)
M4 × 0.7 0.028 Toothed lock washer ø8.5 ø0.335 core bundle × 1 Opposing faces 7 0.276, thickness 2.4 0.094
Fiber
Options FT-H30-M1V-S FT-H35-M2

30 1.181 1,000 39.370 3 27


1.063 2,000 78.740
17 0.118 Heat & cold-resistant Ordinary temperature
Semi-custom 0.669 30 1.181 specifications specifications
fibers 3 0.118
End bracket 4 0.157 17
2.5 0.098 150 16.7 18.3
ø4 [Stainless steel (SUS)] 11
ø4 ø0.157 0.669 5.906 0.657 0.720
ø0.157 0.433

ø2.2
Fiber ø3.6 ø2.9 ø0.114 ø0.087
Opposing faces 7 0.276, M2.6 × 0.45 [Stainless steel (SUS)]
Dimensions thickness 3.2 0.126 ø0.142 Mounting cap nut opposing faces 0.018 Fixing plug (PA)
M2.6 × 0.45 0.018 [Stainless steel (SUS)] 8 0.315 [Stainless steel (SUS)] M4 × 0.7 ø4 ø0.157 [Stainless steel (SUS)] ø5 ø0.197 Fixing bracket
Thru-beam 0.028
Type M4 × 0.7 0.028 Joint [Stainless steel (SUS)] [Brass (Nickel plated)]
Toothed lock washer ø7.6 ø0.299 ø1.2 ø0.047 fiber
[Stainless steel (SUS)] Liner+braid tube [Stainless steel (SUS)] core bundle × 1 Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
Retroreflective
Type Toothed lock washer ø8.5 ø0.335 [Stainless steel (SUS)]
Note: The FT-H30-M1V-S is a set with the FT-H30-M1V, photo-terminal,
Reflective and atmospheric side fiber. Refer to p.66 for dimensions of the
Type
atmospheric side fiber and photo-terminals.
Others
FT-H35-M2S6 FT-HL80Y Free-cut
<with FX-AT3>
60 27
1.063 2,000 78.740 2,000
2.362 Heat & cold-resistant Ordinary temperature 78.740
Amplifiers specifications specifications 1,500 500
59.055 19.685
ø1.2 ø0.047 fiber 5 17 150 16.7 18.3 (25) (Allowable cutting range)
FX-500 core bundle × 1 0.197 0.669 5.906 0.657 0.720 (0.984)
series
FX-100 ø2.2
series ø5 ø0.197 Fixing bracket ø0.087 ø5.5
ø2.2
ø2.1 ø0.083 [Stainless steel (SUS)] [Brass (nickel plated)] ø0.087
ø0.217
ø3 ø0.118 [Stainless steel (SUS)] ø2.9 ø0.114 [Stainless steel (SUS)] Fixing plug (PA) (ø4) (ø0.157) protective tube
ø4 ø0.157 [Stainless steel (SUS)] (Fluorine resin)
M4 × 0.7 0.028
[Stainless steel (SUS)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
INDEX Toothed lock washer ø8.5 ø0.335 [Stainless steel (SUS)]
51
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Thru-beam type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FT-KS40 Free-cut FT-KV26 Free-cut


<with FX-AT4> Fiber
<with FX-AT4> Selection
Guide
20 0.787 2,000 78.740
8
(Set screw tightening range) Beam axis Mounting reference surface Model
0.315 (30) ø1 ø0.039
(1.181) 20 0.787 2,000 78.740 Choose
by shape/
1.5 1.3
18 0.709 application
ø3.5 ø0.138 ø3.7 (ø2) (ø0.079) Model No. tube (m-PPE) (0.5) (0.020) (30) ø1
0.059 0.051 39 (1.181) How to read
Holder (PC) ø0.146 ø0.5 ø0.020 fiber core × 1 (PMMA) Prism (PC) ø1 0.0 ø0.039
Beam axis ø Model No.
End bracket Sheath ø1 ø0.039 (Polyethylene)
[Stainless steel (SUS303)] (ø2) (ø0.079) Model No. tube (m-PPE) Earlier models
4-C0.15 C0.006 End bracket comparison
1.7
0.067 [Stainless steel ø0.5 ø0.020 fiber core × 1 (PMMA) table
2 0.079 (SUS303)] Sheath ø1 ø0.039 (Polyethylene)

FT-KV40, FT-KV40W Free-cut FT-L80Y Free-cut Fibers


<with FX-AT4> <with FX-AT3> Super
2,000 Quality
78.740
25 0.984 2,000 78.740 1,500 500 Threaded
7
ø0 4
.15

59.055 19.685 Type


ø

3.7 (25) (Allowable cutting range)


(30) ø1
0.146 3 0.118
ø0.039
(0.984) Square Head
(1.181)
Type
ø2.5 ø2.2 Cylindrical
ø0.098 Enclosure (ø2) (ø0.079) Model No. tube (m-PPE) ø5.5 Type
ø0.087
Holder (PC) (LCP) ø0.5 ø0.020 fiber core × 1 (PMMA) ø0.217
Prism (PC) (ø4) (ø0.157) protective tube
Sheath ø1 ø0.039 (Polyethylene) (Fluorine resin) Sleeve

Assembly dimensions with MS-FD-3 (attached mounting bracket) Flat


25 0.984 2,000 78.740
FT-R31 Free-cut Type
Prism (PC) 10 0.394 <with FX-AT4> Small
3 3.2 0.126 Spot
Complete thread 10.8 0.425 or more
0.118
3.2 0.126
6.5 3.3 0.130
3.3 (30)
5.5
0.217 8
Cap [Stainless steel (SUS304-CSP)] Narrow
ø1 ø0.039
0.256 0.130 (1.181) 3.7 0.315 2,000 78.740 Beam
0.146 1.7 0.067
4.7 0.185 ø2.5 Wide
6.5 ø0.098 (ø2) (ø0.079) Model No. tube (m-PPE) 3.5 0.138
Beam
R

M3 × 0.5 0.020 Enclosure [ZDC2 (Nickel plated)]


0.256 Holder (PC) FT-KS40 ø0.5 ø0.020 fiber core × 1 (PMMA) 11.3 0.445 Convergent
Mounting bracket Sheath ø1 ø0.039 (Polyethylene) Toothed lock washer M3 [Stainless steel (SUS304)] Reflective
4.1 12.5 0.492 Type
[Stainless steel (SUS304)]
098

0.161 Enclosure (LCP) Hexagon nut M3 [Stainless steel (SUS304)]


1.8 0.071
Retroreflective
R0.

C1 C0.039 5 0.197 ø2.3 ø0.091 Type


2.5

5 0.197 3.8 (ø2) (ø0.079) Model No. tube (m-PPE)


2-R

0.150 (30)
(1.181)
ø1 ø0.039 Chemical / Oil-
ø6.5 5.5 resistant
ø0.256 0.217
FT-KV25 Heat-
Sheath ø1 ø0.039 (Polyethylene) resistant
2.1 0.083
Vacuum-
resistant
FT-R40 Free-cut FT-R41W Free-cut Liquid Leak /
<with FX-AT3> <with FX-AT3> Liquid Detection
2,000 78.740
ø1.2 ø0.047 Stainless pipe 25 ø2.7 ø0.106
[Stainless steel (SUS304)] 0.984 ø2.2 Enclosure 9
20 (30) ø0.087 [Zinc die-cast (ZDC2)] 0.354 2,000 78.740 Fiber
2.4 0.787 (1.181) 6 0.236 Options
0.094 7 0.276 (30)
5 0.197 (1.181)
ø1 ø0.039 fiber core × 1 (PMMA)
R5 1 ±0

Sheath ø2.2 ø0.087 (Polyethylene) 4.4 0.173


±
R0 .03

1 0.039

12 0.472 8 0.315 (ø3.2) (ø0.126) Model No. tube (m-PPE)


.1 9

9.5 0.374
(ø3.2) (ø0.126) Model No. tube (m-PPE) Semi-custom
°±
97

Toothed lock washer M4 [Stainless steel (SUS304)]


90

Fixing bracket [Stainless steel (SUS303)] 2.4 0.094 Hexagon nut M4 fibers
3 0.118 1 0.039 M4 × 0.7 0.028 [Stainless steel (SUS304)]
Toothed lock washer M4 [Stainless steel (SUS304)]
7 0.276 ø2.2 ø0.087
ø2 ø0.079 Hexagon nut M4
[Stainless steel (SUS304)]
ø4 ø0.157 -0.1 -0.004
End bracket [Stainless steel (SUS303)] ø8.5 ø0.335 ø1 ø0.039 fiber core × 1 (PMMA) Fiber
-0.13 -0.005
3.2 0.126 Sheath ø2.2 ø0.087 (Polyethylene) Dimensions
Mounting reference surface M4 × 0.7 0.028
(Screw periphery) Thru-beam
M2.6 × 0.45 0.018 Type

ø8.5 ø0.335 7 0.276 Retroreflective


Type
3.2 0.126 Reflective
Type

FT-R42W Free-cut FT-R43 Free-cut Others


<with FX-AT3> <with FX-AT3>
Complete thread 6.5 0.256 or more Cap [Stainless steel (SUS304-CSP)]
7 9 2,000 78.740
Enclosure 0.276 0.354
7 FT-KV40W
[Zinc die-cast (ZDC2)] 9 2,000 78.740
5.2 2 (30) Amplifiers
0.276 0.205 0.079 (1.181)
0.354
6 (30) 2.4 0.094
0.236 (1.181)
3.5 0.138 FX-500
4.4 0.173 7 0.276
(ø3.2) (ø0.126) Model No. tube (m-PPE) series

8 0.315 10 0.394
1 0.039 (ø3.2) (ø0.126) Model No. tube (m-PPE) M4 × 0.7 0.028 3 0.118
Enclosure [ZDC2 (Nickel plated)] FX-100
Toothed lock washer M4 [Stainless steel (SUS304)] M2.6 × 0.45 0.018 Toothed lock washer M4 [Stainless steel (SUS304)] series
2.4 0.094 Hexagon nut M4 1 0.039
ø2 ø0.079 Hexagon nut M4 [Stainless steel (SUS304)]
M4 × 0.7 0.028 0.5 0.020 [Stainless steel (SUS304)] FT-R41W
Lens 1.8 ± 0.1
(PMMA) 7 0.276 ø2.2 ø0.087 0.071 ± 0.004 4.2 0.165 ø2.2 ø0.087

ø8.5 ø0.335
7 0.276 INDEX
ø8.5 ø0.335 ø1 ø0.039 fiber core × 1 (PMMA)
3.2 0.126 Sheath ø2.2 ø0.087 (Polyethylene) ø1 ø0.039 fiber core × 1 (Acrylic)
3
0.118 Sheath ø2.2 ø0.087 (Polyethylene)
52
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Thru-beam type fibers and reflective type, and in alphabetic order of the Model No.

FT-R44Y Free-cut FT-R60Y Free-cut


Fiber
Selection <with FX-AT3> <with FX-AT3>
Guide

Model
Choose
by shape/ 6 mm 0.236 in or more Cap [stainless steel (SUS304-CSP)]
12.5 mm 0.492 in or more Cap [stainless steel (SUS304-CSP)]
application (complete thread) 9.5 (complete thread)
0.374 2,000 78.740 11
How to read 7 3.5 0.433 2,000 78.740
0.276
Model No 0.138 10 5
5.5 0.394 0.197
Earlier models 0.217 5.5
comparison ø2.2 ø0.087
0.217
table 7 0.276 Head [stainless steel (SUS304)] ø2.2 ø0.087
2.4 0.094 1 0.039
Toothed lock washer M4 14 Head [stainless steel (SUS304)]
3 0.118 [stainless steel (SUS304)] 0.551 Toothed lock washer M6
1.8±0.1 [stainless steel (SUS304)]
M4 × 0.7 0.028 Hexagon nut M4 [stainless steel (SUS304)]
0.071±0.004 M6 × P0.75
Fibers ø2 ø0.079 M2.6 × 0.45 0.018 Hexagon nut M6 [stainless steel (SUS304)]
(1.7 0.067)
Cover [PFA (Fluorine resin)]
Super 7
ø8.5 ø0.335 0.276
Quality ø1.0 ø0.039 fiber core × 1 (PMMA) ø11 ø0.433 10
Outer sheath ø2.2 ø0.087 [PFA (Fluorine resin)] 0.394
Threaded Inner sheath ø1.8 ø0.071 (Polyethylene)
Type
Square Head
Type FT-S11 FT-S20
Cylindrical <with FX-AT2> <with FX-AT2>
Type
6 500 19.685
Sleeve 3
0.236
Set screw 19.5 0.768 2,000
tightening range 0.118 2 8
Flat (30) 0.079 0.315 78.740 (19.7)
10 Set screw (0.776)
Type (1.181) 3 Resin plug (ABS) 10.2
0.394 tightening range 0.118 0.402
Small ø1 (20) (0.3)
ø0.039 (0.787)
Spot ø1 ø0.039 ø2.2 ø0.087 (0.012)
Narrow End bracket [Stainless steel(SUS303)] (ø4.33) (ø0.170)
Beam ø1 (ø4.33)(ø0.170)
ø0.25 ø0.010 fiber core × 1 (PMMA) Resin plug (PA) ø1.5 ø0.059 -0.07 -0.003 ø0.039 ø2.2 ø1.8
Sheath ø0.7 ø0.028 (Polyethylene) -0.10 -0.004 ø0.087 ø0.071
Wide (ø1.5) (ø0.059) Model No. tube (m-PPE)
Mounting reference surface (Periphery) (ø2) (ø0.079) Model No. tube (m-PPE)
Beam
End bracket [Stainless steel (SUS303)]
Convergent
Reflective
Type
Retroreflective
Type FT-S21 Free-cut FT-S21W Free-cut
Chemical / Oil- <with FX-AT4>
resistant <with FX-AT4>
Heat- 2 8
0.079 2,000 2 0.079 2,000 78.740
resistant 8 0.315
0.315 78.740 (Set screw tightening range)
Vacuum- ø1 3 0.118 (Set screw tightening range) ø1
3 0.118 ø1 ø0.039
resistant ø0.039 (30) ø0.039 (30) (1.181)
(1.181)
Liquid Leak /
Liquid Detection ø1 ø0.039 (ø2) (ø0.079) Model No. tube (m-PPE)
ø1.5 ø0.591 -0.07 -0.003 ø1.5 ø0.059 -0.07 ø0.5 ø0.020 fiber core × 1 (PMMA)
-0.003
-0.1 -0.004 -0.1 -0.004 Sheath ø1 ø0.039 (Polyethylene)
(ø2) (ø0.079) Model No. tube (m-PPE) Mounting reference surface
Mounting reference surface (Periphery) End bracket [Stainless steel (SUS303)]
(Screw periphery)
ø0.5 ø0.020 Fiber core × 1 (Acrylic)
Fiber End bracket [Stainless steel (SUS303)] Sheath ø1.0 ø0.039 (Polyethylene)
Options

FT-S30 FT-S31W Free-cut


Semi-custom
fibers <with FX-AT2> <with FX-AT3>
8
2 8 2,000 2 0.079
0.315
2,000 78.740
0.079 78.740 (19.7)
Set screw 0.315 (0.776)
(Set screw tightening range)
5 10.2
5 ø2.2 ø0.087
tightening range 0.197 Resin plug (ABS)
Fiber 0.402 0.197 (30)(1.181)
ø2 (20)
Dimensions ø0.079 (0.787)
(0.3)
(0.012)
Thru-beam (ø3.2) (ø0.126) Model No. tube (m-PPE)
Type ø3 ø0.118 -0.07 -0.003
-0.1 -0.004
ø2.2 (ø4.33)(ø0.170) ø2.2 ø1.8 ø1 ø0.039 fiber core × 1 (PMMA)
Retroreflective ø3 ø0.118 -0.07 -0.003 ø0.087
Mounting reference surface Sheath ø2.2 ø0.087 (Polyethylene)
Type -0.10 -0.004 ø0.087 ø0.071 (Periphery)
Mounting reference surface (Periphery) (ø3.2) (ø0.126) Model No. tube (m-PPE) End bracket [Stainless steel (SUS303)]
ø2 ø0.079
Reflective End bracket [Stainless steel (SUS303)]
Type

Others

FT-S32 Free-cut FT-V23 Free-cut


<with FX-AT3> <with FX-AT5>
Amplifiers FT-S11 8 10 Set screw tightening range
Screw tightening range 1.8 0.071
0.315 2,000 78.740 0.394
FX-500 (excluding crimping part)
2 0.079 ø2.2 View A
series ø2 ø0.079 ø0.087 1.1 0.043 Beam axis
(30)
FX-100
ø0 0.8
31

(1.181) 20 0.787 15 0.591 2,000 78.740


.0

series
ø

ø1 (30)
Lens (PMMA) A ø0.039 (1.181) ø1.3 ø0.051
ø2.5 ø0.098 (ø3.2)(ø0.126) Model No. tube (m-PPE)
End bracket [Stainless steel (SUS303)] ø1 ø0.039 fiber core × 1 (PMMA) ø2 ø0.079 (ø2.5) (ø0.098) Model No. tube (m-PPE)
Crimping part Sheath ø2.2 ø0.087 (Polyethylene) Sleeve [Stainless steel (SUS304)]
INDEX End bracket [Stainless steel (SUS303)] ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
53
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Thru-beam type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FT-V24W Free-cut FT-V25 Free-cut


<with FX-AT4> <with FX-AT4> Fiber
Selection
Guide
View A 10 Set screw tightening range View A 1.8 0.071 10 Set screw tightening range
1
1.8 0.071 0.394 0.394 Model
1 0.039
0.039 2
Choose
0.02 Beam axis Beam axis by shape/

.0 5
55 ø

22
ø0 0.5
ø0. 15 0.591 15 0.591 2,000 78.740 application

ø
15 0.591 15 0.591 2,000 78.740
ø1 (30) ø2 ø0.079
(30) How to read
A ø0.039 ø2 ø0.079 ø1 ø0.039 A (1.181) ø1 ø0.039 Model No.
(1.181)
Earlier models
Sleeve ø1 (ø2) (ø0.079) Model No. tube (m-PPE) comparison
(ø2) (ø0.079) Model No. tube (m-PPE) table
Sleeve [Stainless steel (SUS304)] [Stainless steel (SUS304)] ø0.039
ø0.5 ø0.020 fiber core × 1 (PMMA) ø0.5 ø0.020 fiber core × 1 (PMMA)
End bracket [Stainless steel (SUS303)] Sheath ø1 ø0.039 (Polyethylene)
Sheath ø1 ø0.039 (Polyethylene) End bracket [Stainless steel (SUS303)]

Fibers
Super
Quality
FT-V30 Free-cut FT-V40 Free-cut Threaded
<with FX-AT3> <with FX-AT3> Type
Square Head
View A 2.3 0.091 10 Set screw tightening range Type

57
1.3 0.394
43

ø0 4
.1
.0 25 0.984 2,000 78.740 Cylindrical

ø
0.051
ø0 3.7 0.146 (Set screw tightening range) Type
.1 Beam axis 12
ø1 3 0.118 0.472 ø2.2
(30) ø0.087
20 0.787 15 0.591 2,000 78.740 (8) (0.315) (1.181) Sleeve
FT-V24W
ø1.5 (30) Prism
ø0.059 ø2.2 ø0.087
ø2.5
ø0.098 (ø3.2) (ø0.126) Model No. tube (m-PPE)
Flat
A (1.181) (PC) Type
FT-V25
ø0.75 ø0.030 fiber core × 1 (PMMA)
ø2.5 (ø3.2) (ø0.126) Model No. tube(m-PPE) Window name plate (Polyester) Sheath ø2.2 ø0.087 (Polyethylene) Small
Sleeve [Stainless steel (SUS304)]
ø0.098 End bracket [Stainless steel (SUS303)] Spot
ø1 ø0.039 fiber core × 1 (PMMA) Holder (PC)
End bracket [Stainless steel (SUS303)]
Sheath ø2.2 ø0.087 (Polyethylene) Narrow
Beam
Wide
Beam
FT-V80Y Free-cut FT-Z20HBW Free-cut Convergent
Reflective
<with FX-AT3> <with FX-AT4> Type

2,000 10 Retroreflective
1,000 39.370
78.740
ø2.2 ø0.087 hole, ø3.6 ø0.142 0.394 3.5 Type
1,500 500 spot facing, 1.4 0.055 deep 4-R1 R0.039
59.055 19.685 0.138 Enclosure (PC) Chemical / Oil-
0.5 2 0.079
(25) (Allowable cutting range)
0.020 ø1 resistant
(0.984) 1.05 0.041 (30)
4.5 ø0.039
0.177 (1.181) Heat-
5 0.197 10 0.394 2.5 resistant
ø2.2 0.098 (ø2.0) (ø0.079) Model No. tube (m-PPE)
Sensing part ø5.5 ø0.087 Vacuum-
ø1.5 Inner pipe [Stainless resistant
ø0.217 (ø4) (ø0.157) protective tube steel (SUS304)]
Beam axis mark ø0.059 1 ø0.5 ø0.020 fiber core × 1 (PMMA)
(Fluorine resin) 7 0.039 2.1 Sheath ø1 ø0.039 (Polyethylene) Liquid Leak /
0.276 0.083 Liquid Detection
Beam axis
0.6 0.024

Fiber
Options
FT-Z20W Free-cut FT-Z30 Free-cut
<with FX-AT4> <with FX-AT5>
7 Semi-custom
<Left>
0.276 1,000 39.370
ø0.75 ø0.030 fiber core × 1 (PMMA) fibers
3.5 0.138 Enclosure (PC)
FT-V30
1.2 0.047 ø2.2 ø0.087 hole, ø3.6 ø0.142 Sheath ø1.3 ø0.051 (Polyethylene)
0.5 2 2.5 spot facing, 1.4 0.055 deep
0.020 0.079 0.098 4-R1 R0.039
(30) (1.181) ø1 ø0.039 Beam axis (ø2.5) (ø0.098) Model No. tube (m-PPE) Fiber
5 0.197 10 0.394 FT-Z20HBW
11 0.433
Dimensions
(ø2) (ø0.079) 0.5
Model No. tube (m-PPE) 3 0.118 0.020
7.5
0.5 0.020 Thru-beam
ø1.5 Prism 1.75 2-ø2.2 ø0.087 hole Type
Inner pipe [Stainless steel (SUS304)] 0.069 0.295 ø1.3
ø0.059 (PMMA) (30) ø0.051
Enclosure (PC) 8.5 3.9 0.154 (1.181) Retroreflective
Beam axis 1.05 0.041 0.335 Type
(ø2.5) (ø0.098)
5.5
0.217
Reflective
ø0.5 ø0.020 fiber core × 1 (PMMA) 2.2 0.087 4.3 0.169 Type
Reflector (PC) 12 2,000 78.740
Sheath ø1 ø0.039 (Polyethylene) 0.472
Center of beam axis Others

FT-Z30E Free-cut
<Right> 12
Reflector (PC) 0.472
2,000 78.740
2-ø2.2 ø0.087 hole ø1.3
<with FX-AT5> 5.5
2.2 0.087 0.217 (30) ø0.051
(1.181)
12 2,000 78.740 8.5 Amplifiers
3 0.118 0.472 (30) (1.181) 3.9 0.154
11 3.4 (ø2.5) 0.335 (ø2.5) (ø0.098)
0.433 0.134 ø1.3 4.3 FX-500
(ø0.098) ø0.051 ø0.75 ø0.030 fiber core × 1 (PMMA)
1.75 7.5 0.169
Sheath ø1.3 ø0.051 (Polyethylene) series
3 0.069 0.295
8 0.315 3.5 0.138 0.118 0.5 0.5 0.020 FX-100
ø0.75 ø0.030 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene) 0.020 11 series
Beam 0.433
axis 2 0.079 5.5 2-ø2.2 ø0.087 hole
0.217 Beam axis Enclosure (PC)
Reflector (PMMA) 1.75 0.069 7.5 (ø2.5) (ø0.098) Model No. tube (m-PPE)
0.295

Lens (PMMA) Enclosure (PC) (ø2.5) (ø0.098) Model No. tube (m-PPE) INDEX
FT-V40

FT-Z30
54
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Thru-beam type fibers and reflective type, and in alphabetic order of the Model No.

FT-Z30EW Free-cut FT-Z30H Free-cut


Fiber <with FX-AT5> <with FX-AT5>
Selection
Guide
12 2,000 78.740 12 2,000 78.740
3 0.118 2-ø2.2 ø0.087 0.472 3.4 3 0.118 0.472
Model 11 (ø2.5)
(30) (1.181) Beam
11 3.4 (30) (1.181)
hole axis (ø2.5)
0.433 0.134 (ø0.098)
ø1.3
ø0.051 0.433 0.134 (ø0.098)
ø1.3
ø0.051
Choose
by shape/
application 8 0.315 3.5 0.138 8 0.315 3.5 0.138
ø1 ø0.039 fiber core × 1 (PMMA) ø0.75 ø0.030 fiber core × 1 (PMMA)
How to read Sheath ø1.3 ø0.051 (Polyethylene) Sheath ø1.3 ø0.051 (Polyethylene)
Model No 2 0.079 5.5
Beam axis 2 0.079 0.217
Reflector 5.5 0.217 2-ø2.2 ø0.087 hole
Earlier models 7.5
comparison (PMMA) 1.75 0.069 7.5 0.295 (ø2.5) (ø0.098) Model No. tube (m-PPE) Lens (PMMA) 1.75 0.295
table
0.069

Lens (PMMA) Enclosure (PC) Enclosure (PC) (ø2.5) (ø0.098) Model No. tube (m-PPE)

Fibers
Super FT-Z30HW Free-cut FT-Z30W Free-cut
Quality
<with FX-AT5> <with FX-AT5>
Threaded
Type 12 2,000 78.740 <Left> ø1 ø0.039 fiber core × 1 (PMMA)
0.472
Square Head 3 0.118 (30) Enclosure (PC) Sheath ø1.3 ø0.051 (Polyethylene)
Type 11 3.4 (1.181)
0.433 0.134 (ø2.5)(ø0.098) ø1.3 ø0.051
Cylindrical
Type 8 0.315 Beam 3.5 0.138 Beam axis (ø2.5) (ø0.098) Model No. tube (m-PPE)
axis ø1 ø0.039 fiber core × 1 (PMMA)
11
Sleeve Sheath ø1.3 ø0.051 (Polyethylene)
3 0.118 0.5 0.020 0.433 0.5
Lens 2 0.079 5.5 0.020 (30) (1.181)
0.217 2-ø2.2 ø0.087 hole 1.75 0.069 7.5
Flat (PMMA) 0.295 4.3
Type
1.75 0.069 7.5 0.295 0.169 (ø2.5) ø1.3
(ø0.098) ø0.051
8.5 0.335 3.9 0.154
Small Enclosure (PC) (ø2.5) (ø0.098) Model No. tube (m-PPE)
Spot 2-ø2.2 ø0.087 hole
Narrow Reflector (PC) 2.2 0.087 5.5
Beam FT-Z30H 0.217
Center of 12 2,000 78.740
Wide FT-Z40HBW Free-cut <Right> beam axis 0.472
12
Beam 0.472 2,000 78.740
Convergent <with FX-AT5> Reflector (PC) 5.5 2-ø2.2 ø0.087 hole
Reflective 2.2 0.087 0.217 (30) ø1.3
Type
ø0.051
ø3.2 ø0.126 hole, ø5.6 ø0.220 11 (1.181)
2,000 78.740
Retroreflective spot facing, 2.2 0.087 deep 0.433 3.5 8.5 0.335 3.9 0.154
Type 1 0.039 3.5 0.138 0.138 4-R1 R0.039 (ø2.5) (ø0.098)
1.05 0.041 Enclosure (PC) 4.3 ø1 ø0.039 fiber core × 1 (PMMA)
Chemical / Oil- (30) 1.75 0.069 7.5 0.169
Sheath ø1.3 ø0.051 (Polyethylene)
resistant 3.5 0.138
(1.181)
ø1.3 ø0.051 0.295
7 14 3 0.118 0.5 0.020 0.5 0.020
11
Heat- 0.276 0.551 0.433
(ø2.5) (ø0.098) Model No. tube (m-PPE)
resistant 1.6 Enclosure (PC) Beam axis (ø2.5) (ø0.098) Model No. tube (m-PPE)
0.063 Inner pipe [Stainless steel(SUS304)]
Vacuum- 7 2.7 0.106
resistant ø2.4 ø0.094 0.276

Liquid Leak / Beam ø1 ø0.039 fiber core × 1 (PMMA)


axis
Liquid Detection 0.6 Sheath ø1.3 ø0.051 (Polyethylene)
0.024

Fiber FT-Z40W Free-cut FT-Z802Y Free-cut


Options
<with FX-AT5> <with FX-AT3>
15 2,000
7 0.276 2,000 78.740 0.591 (5.8) 78.740
3.5 0.138 4
ø3.2 ø0.126 hole, ø5.6 ø0.220 (0.228)
Semi-custom 1.2 0.047
spot facing, 2.2 0.078 deep
3 0.157 7.5
0.295
fibers 1 3.5 0.118 2-ø3.2 ø0.126
0.039 0.138 4-R1 R0.039
ø1.3 (7.3) (0.287)
3.5 0.138 (30) (1.181) ø0.051 13 0.512
7 14 FT-Z30W
0.276 0.551 6 ø2.2
Fiber (ø2.5) (ø0.098) Model No. tube (m-PPE)
(1) 0.236 ø0.087
Dimensions Prism Inner pipe [Stainless steel (SUS304)] (0.039)
ø2.4 7 0.276
Thru-beam ø0.094 (PMMA) Enclosure (PC)
Type Beam axis 1.05 0.041 Beam axis

Retroreflective
Type ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø1.3 ø0.051 (Polyethylene)
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
55
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Retroreflective type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FR-KZ22E Free-cut FR-KZ50E Free-cut


<with FX-AT4> <with FX-AT4> Fiber
Selection
Reflector Fiber Guide
15.8 0.622 5.2 0.205 25 0.984 2,000 78.740
0.7 0.028
14.7 0.579 3 0.118 (3.7) Model
1.95 0.077 (30) 2-ø1 ø0.039
(0.146) (1.181)
1.45 0.057 5 Choose
0.197 2-M1.4 × 0.3 0.012 by shape/
9.5 0.374 3.7 0.146 application

11 9 Mounting bracket [Stainless steel (SUS303)] (ø2) (ø0.079) Model No. tube (m-PPE) How to read
0.433 0.354 7.5 Prism Enclosure (ABS) Model No.
0.295 Base (ABS) (PC)
ø0.5 ø0.020 fiber core × 1 (PMMA) Earlier models
Reflector (PMMA) Beam axis comparison
11.2 Sheath ø1 ø0.039 (Polyethylene) table
2.2 0.087 0.441

Fiber
Beam axis
2 0.079
21.5 0.846
7.5
2,000 78.740 Assembly dimensions with MS-FD-2 (attached mounting bracket) Fibers
0.295 .039 2-ø1
1 2 0.079 ) ø0 (30) ø0.039 25 0.984 2,000 78.740
0.039 1.5 (2-ø1 (1.181) 3 0.118 (3.7) Super
0.059 Beam-receiving
(0.146)
(30) 2-ø1 ø0.039 Quality
side (Black) (1.181)
4 0.157
Beam-emitting 9.5 12.2 3.7 0.146 Threaded
1.9 2 0.079 4 side (Gray) Type
2 0.075 0.157 0.374 0.480
0.079 (ø2) (ø0.079) Model No. tube (m-PPE) (ø2) (ø0.079) Model No. tube (m-PPE)
0.7 0.028 Square Head
ø0.5 ø0.020 fiber core × 1 (PMMA)
Prism (PC) 1.5 Sheath ø1 ø0.039 (Polyethylene) 10.2 Type
0.059 5 0.402 4 0.157 3.3 0.130
2 0.079
0.197 Head block [Stainless steel (SUS303)] 5 0.197 Cylindrical
4 9 2-M1.4 × 0.3 0.012 3.3
2-M3 × 0.5 0.020 Type
0.157 0.354 1.2 0.047 0.130 4 MS-FD-2 Mounting bracket
6 0.157
0.236
[Stainless steel (SUS304)] Sleeve
Beam 14 0.551
axis 7
0.276 Flat
Type
FR-KZ50H Free-cut 5.2
0.205 Small
<with FX-AT4> ø0.5 ø0.020 fiber core × 1 (PMMA) Spot
Fiber Prism (PC) Sheath ø1 ø0.039 (Polyethylene)
Enclosure(ABS) Narrow
21 0.827 2,000 78.740 Beam
5.2 0.205 (3.7) (30) Reflector RF-003 (Accessory for FR-KZ50E)
3.7 0.146 (0.146) (1.181)
2-ø1 ø0.039 Wide
10.1
10.6 Beam
9.5 0.398
0.374 5 0.197 0.417 Convergent
Beam axis 10 0.394 Reflective
(ø2) (ø0.079) Model No. tube (m-PPE) 1.1 0.043 Type
(Effective reflector width)
Retroreflective
Type
Enclosure (ABS) ø0.5 ø0.020 fiber core × 1 (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
28 19 Chemical / Oil-
(2-R) 1.102 0.748 (2-R) 10 0.394 resistant
(Effective reflector width)
Assembly dimensions with MS-FD-2 (attached mounting bracket) Heat-
1 0.039 Reflector resistant
21 0.827 2,000 78.740 (Norbornene resin)
(3.7) Vacuum-
(30) 2-ø1 ø0.039 resistant
(0.146) (1.181) Cover [Stainless steel
(SUS304)] 3.2
9.5 12.2 3.7 0.146 0.126 4.3 0.169 Liquid Leak /
0.374 0.480 Liquid Detection
(ø2) (ø0.079) Model No. tube (m-PPE)

10.2 4 0.157 3.3 0.130


5 0.197 0.402

3.3 2-M3 × 0.5 0.020 FR-Z50HW Free-cut Fiber


0.130 MS-FD-2 Mounting bracket Options
1.2 0.047 4
0.157 [Stainless steel (SUS304)] <with FX-AT3>
6FR-KZ22E 14 Fiber
0.236 0.551 1 0.039
7 Lens (BK7) 15 2,000 78.740
0.591
0.276 Semi-custom
5.2 fibers
0.205 4.6 0.181 9.5 0.374
Beam ø0.5 ø0.020 fiber core × 1 (PMMA)
axis Enclosure(ABS) Sheath ø1 ø0.039 (Polyethylene) Enclosure(PC)
2-ø2.2 ø0.087
Reflector RF-003 (Accessory for FR-KZ50H) 5.2 Fiber
10.1 0.205 Dimensions
10.6 Beam axis ø1 ø0.039 fiber core × 1 (PMMA)
0.398 0.417 FR-KZ50E Sheath ø2.2 ø0.087 (Polyethylene)
5 0.197 Thru-beam
10 0.394 Type
1.1 0.043 (Effective reflector width) Assembly dimensions with MS-FD-2 (attached mounting bracket) Retroreflective
Lens (BK7) 15 0.591
1 0.039
2,000 78.740 Type
4.6 0.181 2-M3 × 0.5 0.020
10 0.394 Reflective
28 19
1.102 0.748 (2-R) (Effective reflector width) 9.5 12.2 Type
(2-R) 0.374 0.480
Others
Reflector 10.2
(Norbornene resin) 0.402 4 0.157 3.3 0.130
1 5 0.197
Cover [Stainless steel 0.039 3.3 0.130 MS-FD-2 Mounting bracket
3.2 4.3 [Stainless steel (SUS304)]
(SUS304)] 0.126 4 0.157
0.169 1.2 0.047 14 0.551 2-ø2.2
6 7 0.276 Enclosure (PC) ø0.087 Amplifiers
0.236
5.2
0.205 FX-500
Beam axis ø1 ø0.039 fiber core × 1 (PMMA) series
Sheath ø2.2 ø0.087 (Polyethylene)
FX-100
Reflective tape RF-13 (Accessory for FR-Z50HW) series

0.5 0.020 30 1.181

FR-Z50W
30 INDEX
1.181
Rear surface
(pressure-sensitive adhesive)
Reflective surface (Acrylic)

FR-KZ50H
56
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Reflective type fibers and reflective type, and in alphabetic order of the Model No.

FD-30 FD-31 Free-cut


Fiber
Selection <with FX-AT2> 2 <with FX-AT4>
Guide 2 2,000 0.079 2,000
10 78.740 ø6.5 10
ø6.5 0.079 (19.7) ø0.256 78.740 ø1
Model ø0.256 2.7 0.394 Resin plug(ABS) (0.776) 10.2 0.394
1.8 2.7 (30) ø0.039
0.106 ø2 0.071 0.402 0.106 ø2 1.8
Choose (20) (0.3) 0.071 (1.181)
ø0.079 (0.787) ø0.079
by shape/ (0.012)
application
How to read
Model No (ø2) (ø0.079) Model No. tube (m-PPE)
ø3 ø0.118 -0.1 -0.004
Earlier models ø3 ø0.118 -0.10 -0.004 ø1 -0.13 -0.005
comparison -0.13 -0.005 M3 × 0.5 ø2.2 ø1.8 ø0.5 ø0.020 Fiber core × 1 (Acrylic)
Mounting reference surface (Screw periphery) ø0.039 (ø4.33) ø0.087 ø0.071 Mounting reference surface (Screw periphery)
table 0.020 Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)] (ø0.170) (ø2) (ø0.079) Model No. tube (m-PPE) End bracket [Stainless steel (SUS303)]
Toothed lock washer M3 M3 × 0.5 0.020
Opposing faces 5.5 0.217 [Stainless steel (SUS)] Opposing faces 5.5 0.217
thickness 1.8 0.071 [Stainless steel (SUS)] thickness 1.8 0.071 [Stainless steel (SUS304)] Toothed lock washer M3 [Stainless steel (SUS304)]

Fibers
FD-31W Free-cut FD-32G Free-cut
Super
Quality <with FX-AT4> <with FX-AT6>
Threaded ø6.5 2 0.079 ø6.5 17 0.669 2,000 78.740
Type ø0.256 10 2,000 78.740 ø0.256 12 0.472 30 ø1
5.5 0.394 5.5 1.2 1.181 ø0.039 Beam-emitting
0.217 (30)
Square Head (1.181)
0.217 0.047 1.8
0.071
side
Type 2.7 1.8 0.071
0.106 (ø2) (ø0.079) Model No. tube(m-PPE) Beam-receiving
Cylindrical ø2.3
2-ø1 ø0.039 ø0.091 side
Type Details of
ø2 M3 × 0.5 ø3 ø0.118 Sheath ø1.3 ø0.051 ø1.3 ø0.051
Sleeve End bracket ø0.079 M3 × 0.5 (ø2) (ø0.079) sensing part 0.020 End bracket (Polyethylene)
[Stainless steel (SUS303)] 0.020 Model No. tube (m-PPE) 2.8 0.110 [Stainless steel (SUS303)] Sheath ø1 ø0.039 (Polyethylene)
Flat ø0.5 ø0.020 fiber core × 1 (PMMA) Hexagon nut M3
Type Hexagon nut M3 Sheath ø1 ø0.039 (Polyethylene) [Stainless steel (SUS304)]
[Stainless steel (SUS304)]
Toothed lock washer M3 [Stainless steel (SUS304)] Toothed lock washer M3 [Stainless steel (SUS304)]
Small
Spot Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Narrow Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
Beam
Wide
Beam FD-32GX Free-cut FD-40
Convergent
Reflective
<with FX-AT6> <with FX-AT2>
Type
18 0.709 1,000 39.370 2,000
Retroreflective 2 12
12 0.472 300 11.811 700 27.559 ø8.5 0.079 78.740
Type 1.2 6 (Allowable cutting range) ø0.335 3.5 0.472 Resin plug(ABS)
(19.7)
(2.5) 0.236 (0.776) 10.2
ø6.5 0.047 2.4
Chemical / Oil- (0.098) ø4.5 ø1 0.138 (20) 0.402
ø0.256 ø4.5 (2.5) ø0.177 ø0.039 Beam-emitting ø2.5 0.094 (0.3)
resistant 5.5 ø0.177 ø3.8 (30)
(0.098) side ø0.098 (0.787) (0.012)
0.217 ø2.3 ø0.091 ø0.150 (1.181)
Heat- ø1.3
resistant ø0.051 Beam-receiving
side
Vacuum- Crimping
ø4 ø0.157 -0.10 -0.004
M3 × 0.5 0.020 Crimping
part part Sheath ø1 ø0.039 M4 × 0.7 ø1 ø2.2 ø1.8
resistant -0.13 -0.005
ø0.039 (ø4.33)
End bracket FD-31W ø0.087 ø0.071
(Polyethylene) 0.028
[Stainless steel (ø5.1) (ø0.201) Mounting reference surface (Screw periphery) (ø0.170) (ø2) (ø0.079) Model No. tube (m-PPE)
Liquid Leak / (SUS303)] Model No. tube (m-PPE) Sheath ø1.3 ø0.051
Liquid Detection Hexagon nut M3 End bracket [Brass (Nickel plated)]
Toothed lock washer [Stainless steel (SUS304)]
(Polyethylene) Toothed lock washer M4 [Brass (Nickel plated)]
M3[Stainless steel Intermediate fixing bracket Opposing faces 7 0.276
(SUS304)] [Stainless steel (SUS303)] thickness 2.4 0.094 [Brass (Nickel plated)]
Protective tube
Details of sensing part (Polyolefin tube included SUS304 spiral tube)
Fiber
Options
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)
Semi-custom
fibers
FD-41 Free-cut FD-41S Free-cut
2 <with FX-AT4> <with FX-AT4>
0.079 12 2,000
ø8.5 ø8.5
Fiber 0.472 78.740 ø1 ø0.335 40 1.575 12 0.472 2,000 78.740
Dimensions ø0.335 2.4 ø0.039 7 0.276 5 (30) 2-ø1
ø2.5 (30) Allowable
10 0.197
2.4 ø0.039
3.5 ø0.098 0.094 3.5 10 bending 0.094 (1.181)
Thru-beam 0.138 (1.181) 0.138 0.394 range 0.394
Type (ø2) (ø0.079) Model No. tube (m-PPE)
ø2.5
Retroreflective ø1.48 ø0.098
ø0.058 Sleeve [Stainless
Type -0.1 -0.004 (ø2) (ø0.079) Model No. tube (m-PPE) M4 × 0.7
ø0.5 ø0.020 fiber core × 1 (PMMA)
ø4 ø0.157-0.13 steel (SUS304)] Sheath ø1 ø0.039 (Polyethylene)
-0.005 0.028
Reflective ø0.5 ø0.020 Fiber core × 1 (Acrylic)
Type Mounting reference surface (Screw periphery) Toothed lock washer M4 [Stainless steel (SUS304)]
End backet [Stainless steel (SUS303)] Sheath ø1 ø0.039 (Polyethylene)
Hexagon nut M4 [Stainless steel (SUS304)]
Others Opposing faces 7 0.276 M4 × 0.7 0.028
thickness 2.4 0.094 [Stainless steel (SUS304)] End bracket [Stainless steel (SUS303)]
FD-32G
Toothed lock washer M4
[Stainless steel (SUS304)]
FD-32GX

Amplifiers
FD-41SW Free-cut FD-41W Free-cut
<with FX-AT4> <with FX-AT5>
FX-500
series ø8.5 ø8.5 2 0.079 12 0.472 2,000 78.740
ø0.335 40 1.575 12 0.472 2,000 78.740 ø0.335
7 7 0.276 (30)
FX-100 0.276
5
(30) 2-ø1 2.4 0.094 (1.181)
series Allowable 0.197 2.4 ø0.039 3.5 0.138
3.5 10 10 (1.181)
0.138 bending 0.094
0.394 range 0.394 2-ø1.3 ø0.051
ø3 ø0.118
ø1.48 ø2.5 ø0.098 M4 × 0.7 (ø2.5) (ø0.098) Model No. tube (m-PPE)
ø0.058 (ø2) (ø0.079) End bracket [Stainless steel (SUS303)] 0.028
INDEX Sleeve [Stainless steel M4 × 0.7 0.028 Model No. tube (m-PPE) Toothed lock washer M4 [Stainless steel (SUS304)] ø1 ø0.039 fiber core × 1 (PMMA)
(SUS304)] Toothed lock washer M4 [Stainless steel (SUS304)] Sheath ø1.3 ø0.051 (Polyethylene)
ø0.5 ø0.020 fiber core × 1 (PMMA) Hexagon nut M4
Hexagon nut M4 [Stainless steel (SUS304)] Sheath ø1 ø0.039 (Polyethylene) [Stainless steel (SUS304)]
End bracket [Stainless steel (SUS303)]
57
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Reflective type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FD-42G Free-cut FD-42GW Free-cut


Fiber
<with FX-AT6> <with FX-AT6> Selection
Guide
25 0.984 2,000 78.740 25 0.984 2,000 78.740
5 12 0.472 ø8.5 5 Model
ø8.5 0.197 (30) ø0.335 0.197 12 0.472 2.4 (30)
ø0.335 2.4 ø1 ø1
1.2 0.094 (1.181) ø0.039 7 0.094 (1.181) ø0.039 Choose
7 0.047 0.276 1.2 by shape/
0.276 0.047 Beam-emitting application
Beam-emitting side
side ø1.3 ø0.051 How to read
ø1.3 ø0.051
ø2.3 ø2.3 Beam-receiving Model No.
Beam-receiving ø0.091 ø4 side
ø0.091 ø4 side Earlier models
ø0.157 (ø2) (ø0.079) Model No. tube (m-PPE) comparison
ø0.157 (ø2) (ø0.079 ) Model No. tube (m-PPE) M3 × 0.5 0.020 table
M3 × 0.5 0.020 Sheath ø1 ø0.039 (Polyethylene)
M4 × 0.7 0.028
M4 × 0.7 0.028 Sheath ø1 ø0.039 (Polyethylene) Sheath ø1.3 ø0.051 (Polyethylene)
Toothed lock washer M4 Sheath ø1.3 ø0.051 (Polyethylene) End bracket [Stainless steel (SUS303)]
[Stainless steel (SUS304)] Hexagon nut M4
End bracket [Stainless steel (SUS303)]
3.5
[Stainless steel (SUS304)] Fibers
Hexagon nut M4 0.138 Toothed lock washer M4 [Stainless steel (SUS304)]
3.5
0.138
[Stainless steel (SUS304)] Super
Details of Quality
Details of sensing part Threaded
sensing part Type
Square Head
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA) Type
Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)
Cylindrical
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA) Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA) Type

Sleeve

Flat
FD-60 FD-61 Free-cut Type
Small
<with FX-AT2> 2
<with FX-AT3> Spot
ø11 0.079 15 2,000
2,000 ø0.433 Narrow
ø11 2 15 0.591 78.740
0.591 78.740 (19.7) 5.5 2 0.079 ø2.2 Beam
ø0.433 0.079 ø4.5 (30) ø0.087
5.5 Resin plug (ABS) (0.776) 0.217
ø0.177 (1.181)
0.217 ø4.5
2 10.2 Wide
0.079 (20) (0.3) 0.402 Beam
ø0.177 (0.787) (0.012) Convergent
Reflective
Type
-0.1 -0.004
ø6 ø0.236-0.13 (ø3.2) (ø0.126) Model No. tube (m-PPE) Retroreflective
-0.005
ø2.2 ø1.8 Type
ø6 ø0.236 -0.10 -0.004 ø2.2
(ø4.33) Mounting reference surface (Screw periphery) ø1 ø0.039 Fiber core × 1 (Acrylic)
-0.13 -0.005 M6 × 0.75 ø0.087 (ø0.170) ø0.087 ø0.071 Sheath ø2.2 ø0.087 (Polyethylene)
(ø3.2) (ø0.126) Model No. tube (m-PPE) End bracket [Stainless steel (SUS303)] Chemical / Oil-
Mounting reference surface (Screw periphery) 0.030 resistant
Opposing faces 10 0.394 M6 × 0.75 0.030
End bracket [Brass (Nickel plated)] Toothed lock washer M6 [Brass (Nickel plated)] thickness 2 0.079 [Stainless steel (SUS304)]
Heat-
Opposing faces 10 0.394 Toothed lock washer M6 resistant
thickness 2 0.079 [Brass (Nickel plated)] [Stainless steel (SUS304)]
Vacuum-
resistant
Liquid Leak /
FD-61G Free-cut FD-61S Free-cut Liquid Detection

<with FX-AT3> <with FX-AT3>


2 15 2,000 78.740 40 1.575 15 2,000 78.740
ø11 ø0.433 0.079
2
0.591 (30) 2-ø2.2 ø0.087 ø11 ø0.433 0.591 2-ø2.2 ø0.087 Fiber
ø4.5
10 0.394
ø0.177 0.079
(1.181) 10 0.394 Allowable 5 0.197 2 (30) Options
5.5 10 bending 10 (1.181)
0.217 0.394 0.079
(ø3.2) (ø0.126) Model No. tube (m-PPE) range 0.394

ø3.5
Hexagon nut M6 [Stainless steel (SUS304)] Sheath ø2.2 ø0.087
ø2.5 ø0.098 ø0.138 Semi-custom
(Polyethylene) Sleeve [Stainless steel (SUS304)] M6 × 0.75 0.030 (ø3.2) (ø0.126) fibers
Details of Model No. tube (m-PPE)
sensing part Toothed lock washer M6 [Stainless steel (SUS304)] Toothed lock washer M6 [Stainless steel (SUS304)]
Hexagon nut M6 [Stainless steel (SUS304)] ø1 ø0.039 fiber core × 1 (PMMA)
End bracket [Stainless steel (SUS303)] Sheath ø2.2 ø0.087 (Polyethylene)
5.5
0.217
M6 × 0.75 0.030
End bracket Fiber
[Stainless steel (SUS303)] Dimensions
Thru-beam
Type
Beam-receiving ø0.25 ø0.010 fiber core × 16 (PMMA)
Retroreflective
Beam-emitting ø1 ø0.039 fiber core × 1 (PMMA)
Type
Reflective
Type

Others
FD-61W Free-cut FD-62 Free-cut
<with FX-AT3> <with FX-AT3>
ø11 ø0.433 ø11 ø0.433 2 15 2,000 78.740
2 15 2,000 78.740 10 0.394 0.079 0.591 2-ø2.2 ø0.087
10 0.394 0.079
2
0.591
(30) (1.181)
2-ø2.2 ø0.087 5.5 0.217 2 (30) (1.181) Amplifiers
5.5 0.217 0.079
0.079
FX-500
(ø3.2) (ø0.126) Model No. tube (m-PPE) series
(ø3.2) (ø0.126) ø4.5
Model No. tube (m-PPE) ø0.177
ø4.5 FX-100
ø0.177 -0.1 -0.004 Hexagon nut M6 ø1.5 ø0.059 fiber core × 1 (PMMA) series
ø6 ø0.236-0.13 [Stainless steel (SUS304)] Sheath ø2.2 ø0.087 (Polyethylene)
Hexagon nut M6 M6 × 0.75 0.030 ø1 ø0.039 fiber core × 1 (PMMA) -0.005
[Stainless steel (SUS304)] End bracket Sheath ø2.2 ø0.087 (Polyethylene) Mounting reference End bracket [Stainless steel (SUS303)]
[Stainless steel (SUS303)] surface (Screw periphery) Toothed lock washer M6 × 0.75 0.030
Toothed lock washer M6
[Stainless steel (SUS304)] M6 [Stainless steel (SUS304)]
INDEX
58
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Reflective type fibers and reflective type, and in alphabetic order of the Model No.

FD-64X FD-A16 Free-cut


Fiber
Selection <with FX-AT3>
Guide
ø3.8 Lens 2 0.079
ø4.5 ø4.5 2-ø2.2 ø0.087 28 1.102 2,000 78.740
Model ø0.177 ø0.177
ø0.150 (30) (Norbornene resin) 3.6 0.142
4.5 0.177 5.1 0.201 2-ø2.2 ø0.087
(1.181) 8 0.315
Choose B
by shape/ Protective tube 15 Beam-receiving side
application
0.591 9 0.354
Polyolefin tube included (ø5.1) Beam axis
How to read SUS304 spiral tube (ø0.201) Resin plug (ABS) A
Model No 22 Beam-emitting side
1,000 39.370 2-ø3.3 ø0.130
Earlier models 2 0.866 6 0.236
comparison 0.079 15 (2.5) 10.7 0.421 Enclosure (PC)
table 10 0.591 (0.098)
0.394 2 (5.8) (0.228)
Details of 0.079 7 0.276
sensing part 7 11 11.6 Sheath ø2.2 ø0.087 (Polyethylene)
0.276 0.433 0.457
5.5 ø11 ø0.433 Crimping part
Fibers 0.217 End bracket M6 × 0.75 0.030 (ø5.1) (ø0.201) Model No. tube (m-PPE) View A View B
[Stainless steel (SUS303)]
Hexagon nut M6 [Stainless steel (SUS304)] Beam-emitting ø1 ø0.039 fiber core Beam-receiving ø0.25 ø0.010 fiber core
Super Toothed lock washer M6 × 1 (PMMA) × 16 (PMMA)
Quality [Stainless steel (SUS304)]
ø0.25 ø0.010 fiber core × 9 (PMMA)
Threaded (each beam-emitting part and beam-receiving part)
Type
Square Head
Type
Cylindrical
FD-AL11 Free-cut FD-E13
Type <with FX-AT3>
Sleeve 20 4 0.157 (Set screw tightening range) 2-ø2.2 ø0.087
0.787 2,000 78.740 4.5 0.177 5.1 0.201
5 0.197 13 (30)
Flat 2.5 0.098
ø1.5 ø0.059 ø0.9 ø0.035
(1.181)
Type 0.512

Small 2-M3 × 0.5 0.020 ø0.48 ø0.019 (ø2.5) (ø0.098)


20 15 2-ø2.2
Spot Head block 0.787 0.591 ø0.087
(LCP) 5 0.197
3 15 1,000 39.370
Narrow 0.118 0.591 6 0.236
Beam (1) (0.039) 10.7
Details of 2.5 0.421
Wide sensing part 0.098 5 ø0.25 ø0.010 × 16 fiber core (PMMA)
Beam 0.197 Sheath ø2.2 ø0.087 (Polyethylene) (3.1) (0.122)
1 0.039
Convergent Enclosure (PPS)
Reflective 7 11 11.6
Type 0.276 0.433 0.457
Retroreflective 10.85 0.427
Sleeve [Stainless steel
Type (SUS304)]
Resin plug (ABS)
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Chemical / Oil- Details of
Sensing part ø0.25 ø0.010 fiber core × 32
resistant (emitter / receiver alternating line)
(ø0.9) (ø0.035) Protective tube (Polyolefin)
sensing part End bracket
Heat- [Stainless steel (SUS303)]
resistant
Vacuum-
resistant ø0.125 ø0.005 fiber core × 2 (PMMA)
(each beam-emitting part and beam-receiving part)
Liquid Leak /
Liquid Detection

FD-E23 FD-EG30
Fiber
Options
2-ø2.2 ø0.087 2-ø2.2 ø0.087
ø3 ø0.118 (30) 4.5 0.177 5.1 0.201 (30)
(1.181) 4.5 0.177
(1.181)

Semi-custom 5.1 0.201


ø0.63 ø0.025 (ø3)
fibers (ø0.118)
Resin plug (ABS)
(ø3)
(ø0.118) Resin plug (ABS)
(ø1.6) (ø0.063) Protective tube (Polyolefin) (ø1.6) (ø0.063) Protective tube (Polyolefin)
16 500 19.685
0.630 FD-E13 6 0.236
Fiber 5 0.197 5.5 1.2
(1) (0.039) 10.7
0.421
Dimensions 15 1,000 39.370 0.217 0.047 1.8 (3.6) (0.142)
Beam-receiving
0.591 6 0.236 0.071
Thru-beam (1) (0.039) 10.7 7 11 11.6 side
Type 0.421 ø6.5 ø2.3 0.276 0.433 0.457 Beam-emitting
(3.4) (0.134) ø0.256 ø0.091 M3 × 0.5 0.020 side
Retroreflective Beam-receiving
End bracket (ø3) (ø0.118) Model No. tube (m-PPE)
Type 7 11 11.6 side Details of sensing part [Stainless steel (SUS303)]
0.276 0.433 0.457 Beam-emitting 2.8
Reflective End bracket side 0.110 Hexagon nut M3
Type [Stainless steel (SUS303)] [Stainless steel (SUS304)]
(ø3) (ø0.118) Model No. tube (m-PPE)
Details of Toothed lock washer M3 [Stainless steel (SUS304)]
Others Sleeve [Stainless steel (SUS304)]
sensing part
Beam-emitting ø0.25 ø0.010 fiber core × 1 (PMMA)

Beam-receiving ø0.125 ø0.005 fiber core × 9 (PMMA)


Beam-receiving ø0.125 ø0.005 fiber core × 9 (PMMA)
Amplifiers
FX-500 Beam-emitting ø0.25 ø0.010 fiber core × 1 (PMMA)
series
FX-100
series

INDEX
59
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Reflective type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FD-EG30S FD-EG31
Fiber
Selection
Guide
2-ø2.2 ø0.087 2-ø2.2 ø0.087
ø2.3 ø0.091 (30) 4.5 0.177 Model
ø0.8 ø0.031 (30) 4.5 0.177 5.1 0.201 (1.181)
(1.181)
5.1 0.201 Choose
by shape/
(ø3) (ø2.5) application
Sleeve (ø0.098) Resin plug (ABS)
[Stainless steel (SUS304)] (ø0.118) Resin plug (ABS) How to read
(ø1.6) (ø0.063) Protective tube (Polyolefin) (ø1.2) (ø0.047) Protective tube (Polyolefin) Model No.
16 500 19.685
15 0.630 6 0.236 Earlier models
15 0.591 1,000 39.370 5.5 comparison
6 0.236 10.7 1.3 0.051 1.8 (1) (0.039) 10.7
0.591 1.8 (1) (0.039) 0.217 table
0.071 0.421 0.071 (3.1) (0.122) 0.421
5.5
0.217 (3.6) (0.142) Beam-receiving Beam-receiving
7 11 11.6 side
7 11 11.6 side 0.276 0.433 0.457 Beam-emitting
ø6.5 0.276 0.433 0.457 Beam-emitting M3 × 0.5 0.020
ø0.256 M3 × 0.5 0.020 ø6.5 ø0.256 side
side
(ø3) (ø0.118) Model No. tube (m-PPE)
(ø2.5) (ø0.098) Model No. tube (m-PPE) Fibers
Hexagon nut M3
Details of sensing part End bracket [Stainless steel (SUS303)]
Details of sensing part 2.8 0.110 Hexagon nut M3 Super
[Stainless steel (SUS304)] Quality
2.7 0.106 [Stainless steel (SUS304)]
Toothed lock washer M3 [Stainless steel (SUS304)]
Toothed lock washer M3[Stainless steel (SUS304)] Threaded
End bracket [Stainless steel (SUS303)] Type

Beam-emitting ø0.25 ø0.010 fiber core × 1 (PMMA) Beam-emitting ø0.125 ø0.005 fiber core × 1 (PMMA) Square Head
Type
Beam-receiving ø0.125 ø0.005 fiber core × 6 (PMMA)
Beam-receiving ø0.125 ø0.005 fiber core × 9 (PMMA) Cylindrical
Type

Sleeve
FD-F4, FD-F41 Free-cut FD-F41Y Free-cut
<with FX-AT4> <with FX-AT4> Flat
20 Type
0.787
8 2,000
0.315 78.740 Small
5 2-ø3.2 ø0.126 mounting holes 500 Spot
0.197 19.685
(50)
6 0.236
(ø3) (ø0.118) (1.969) Protective tube Narrow
13.5 Model No. tube (m-PPE) Range where cutting is not possible ø1 ø0.039 × 2 Beam
25 0.531 14 ø1 ø0.039 × 2 (0.8) (17) Bending prohibited range Primary sheath: Polyethylene
0.984 0.551 (4.44) (0.669) Secondary sheath: [PFA (fluorine resin)] Wide
(0.031) Beam
(0.175) (10) Crimping part
(1.0) (0.039) Convergent
(20) (0.039) Reflective
14 (0.787) 2,000 Type
0.551 78.740 (ø4) (ø0.157) Protective tube Retroreflective
4 (ø1.15) [PFA (fluorine resin)]
0.157 Type
(ø0.045)
13 Chemical / Oil-
0.512 resistant
10 FD-EG31 Heat-
0.394 resistant
Vacuum-
resistant
FD-F71 Free-cut FD-F8Y Free-cut Liquid Leak /
<with FX-AT4> <with FX-AT3> Liquid Detection
Fiber 1,000 1,000
5,000 196.850 2-ø1 39.370 39.370
Emission indicator 3,000 118.110 (26) (1.024) (Allowable cutting range)
30 1.181 ø0.039
7.8 0.307
Beam-emitting side (Bending prohibited range) Fiber
10 (Gray) 8 16 Options
Beam-receiving side 0.315 0.630
20 0.394
0.787 (Black)
ø0.25 ø0.010 fiber core × 4 (PMMA)
Outer sheath ø1 ø0.039 (Polyethylene)
[PFA(Fluorine resin)]
(ø3.1) (ø0.122) Protective tube Semi-custom
[PFA(Fluorine resin)] ø2.2 ø0.087 × 2 fibers
10 (ø6) (ø0.236) protective tube (Fluorine resin)
0.394
22 0.866

Fiber
Dimensions
SUS mounting bracket SUS mounting bracket (FD-71) FD-FA93 Free-cut Thru-beam
17 mounting diagram <with fiber attachment> Type
0.669
10 6.2 0.244 30 1.181 Retroreflective
0.394 0.3
0.012 10
Details of sensing part Type
15 0.394
17.7 12.2 0.480 0.591 Reflective
5.5 0.217 Mounting holes (for tying band)
0.697 11 0.433 17 8.75 Type
FD-F71
11.5
0.669 0.344
ø4.2 ø0.165 thru-holes
0.453 SUS mounting bracket Others
Material: [PFA(Fluorine resin)] 2.5
(9.4) 6.5 3 0.118
Material: Stainless steel (SUS316) 10.3 0.406 (0.370) 0.098
0.256 0.9 0.035 Sensing part
(emitter / receiver
0.3 0.012 7.8 0.307 5.2 0.205 alternating line)
20.3 17.1
22.2 0.673 (ø0.25 ø0.010 fiber core × 18)
28.3 0.799 0.874 Amplifiers
1.114
Enclosure (ABS) FX-500
PVC mounting bracket PVC mounting bracket 5.2 0.205 series
(FD-71) mounting diagram ø0.25 ø0.010 fiber core × 9 (PMMA) FX-100
12 Sheath ø1.3 ø0.051 (Polyethylene) series
0.472 30 1.181
10 5.7 10 2,000
0.394 0.224 0.394 78.740
25 2.5
15.5 10.5 0.413 0.984 3 0.118
FD-F71 2-ø1.3 0.098
0.610
4 0.157
ø0.051 INDEX
11 11.5 PVC mounting bracket
Welding part 0.453
0.433
Material: PVC
10 0.394
60
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Reflective type fibers and reflective type, and in alphabetic order of the Model No.

FD-H13-FM2 Free-cut FD-H18-L31 Free-cut


Fiber
Selection <with FX-AT3> <with FX-AT3>
Guide
Details of 7 20 2,000
5 16 0.276 0.787 78.740
Model sensing part 0.197 0.630
2,000
78.740 10.75 6.5
5.5 15 0.423 0.256
Choose ø1.5 ø0.059
by shape/ fiber core × 2 0.217 0.591 2.7
application 0.106
How to read 19 A
Model No 0.748 A
Earlier models Screw tightening ø2.2 ø0.087 × 2 ø2.2 ø0.087 × 2
comparison face ø5 (Fluorine resin) End bracket (Brass)
table
8 (Fluorine resin)
ø0.197 Opposing faces 10 0.394, thickness 2 0.079 0.315 2-M3 × 0.5 0.020
Toothed lock washer ø11 ø0.433 4 Head [Stainless steel (SUS)]
M6 × 0.75 0.030 0.157 Holder [Stainless steel (SUS)]
5
0.197
Fibers
Super
Quality
ø4.6 View A
Threaded ø0.181
Emitter / Receiver fiber
Type ø1.5 ø0.059 × 1
Square Head
Type
Cylindrical
Type

Sleeve
FD-H20-21 FD-H20-M1
Flat
Type
Details of Details of Heat & cold-resistant Ordinary temperature
Small specifications specifications
Spot
sensing part 27 1,000
sensing part Joint [Brass (Nickel plated)]
1.063 39.370 60 35 ø2.2
Beam-receiving part: 20 30 ø0.087 Beam-receiving part: 28 1,000
Narrow ø50 µm ø1.969 mil × 440 ø3.1
2.362 1.378
inside diameter ø1.1 ø0.043
0.787 1.181 1.102 39.370
Beam Beam-emitting part: ø0.122 ø10 16.7 18.3 Beam- outside diameter ø1.6 ø0.063 150 25 60 ± 5
5 0.657 0.720 emitting 16.7 18.3
Wide ø50 µm ø1.969 mil × 440 0.197 5 ø0.394
side fiber core bundle × 1 5 15 5.906 0.984 2.362 ± 0.197 0.657 0.720 Beam-
Beam 0.197 ø5 ø0.197 5.5 0.197 0.591 receiving
Emitter mark 0.217 D side
Convergent 3.5 ø4 Beam- ø2.2 ø0.087
Reflective ø0.157 ø5 ø0.197 receiving
Type 0.138 side P Beam-
ø3 ø0.118 ø2.9 ø0.114 Screw ø9 ø0.354 emitting
M4 × 0.7 Liner + braid tube ø6 ø4.2 ø0.165 (Silicone)
Retroreflective Toothed lock washer ø8.5 ø0.335 0.028 [Stainless steel (SUS)] Joint tightening face
ø0.236 side
Type ø5 Fixing plug (PA)
Beam-emitting part: ø3.5
[Stainless steel (SUS)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)] End bracket
Chemical / Oil- ø1.1 ø0.043 fiber ø0.138 [Brass (Nickel plated)] ø0.197 Fixing bracket
resistant core bundle × 1 [Brass (Nickel plated)]
M6 × 0.75 Opposing faces 10 0.394,
0.030 thickness 2 0.079 ø2.9 ø0.114 (Silicone)
Heat-
resistant Toothed lock washer ø11 ø0.433
Vacuum-
resistant
Liquid Leak /
Liquid Detection

FD-H25-L43 FD-H25-L45
Fiber
Options <with FX-AT2> <with FX-AT2>
33.2 3,000 34.5 3,000
1.307 6.5 118.110 19.5
1.358 118.110
21.7 6.5 19.5
0.256 Ordinary 0.768 23 0.256 Ordinary
0.854 Heat-resistant temperature 0.906 0.768
Heat-resistant temperature
Semi-custom specifications specifications specifications specifications
4.5 ø2.9 ø2.9
fibers 5 ø0.114 (150) 10 5 4.5
ø0.114 (150) 10
0.177 (5.906) 0.394 Beam- 0.177 0.394
0.197 0.197 (5.906) Beam-
A emitting side A emitting side
21 (ø4.33) (ø0.170) Beam- 21 (ø4.33) (ø0.170) Beam-
0.827 0.827
Fiber A receiving side A receiving side
2 0.079 2
Dimensions ø2.2 ø0.087 × 2 ø2.2 ø0.087 × 2
ø3.8 ø0.150 0.079 ø3.8 ø0.150
Thru-beam
Type Tube [Stainless steel (SUS)] Tube [Stainless steel (SUS)]
Retroreflective 2-mounting holes for M3 countersunk head screw 2-mounting holes for M3 countersunk head screw
Type Fiber holder (Heat-resistant resin)
Prism (BK7) Prism (BK7) Fiber holder (Heat-resistant resin)
Reflective Enclosure (Heat-resistant resin)
Type Enclosure (Heat-resistant resin)
Slit mask [Stainless steel (SUS)] Slit mask [Stainless steel (SUS)]
ø5 (24.2) View A View A
ø0.197 ø5
Others Beam axis (0.953) ø1.2 ø0.047 (Beam-receiving fiber ø0.197 (24.2) ø1.2 ø0.047 (Beam-receiving fiber
Beam axis (0.953) ø1.5 ø0.059) fiber core × 1
ø1.5 ø0.059) fiber core × 1

Resin plug (PA) Resin plug (PA)

Amplifiers Fixing bracket [Brass (Nickel plated)] Fixing bracket [Brass (Nickel plated)]

FX-500
series
FX-100
series

INDEX
61
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Reflective type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FD-H30-KZ1V-S FD-H30-L32
Fiber
15
0.591 (0.854
21.7
) 1,000 39.370
30 1.181
7
0.276
20
0.787 16.7
2,000
78.740
Selection
Guide
11 4 0.157 0.657 16.7
0.433 ø4 ø0.157 10.75 6.5 0.657 Model
18.3
ø4 0.423 0.256 0.720
Glass lens (BK7) ø0.157 ø4 ø2.9 ø5
ø0.197 Choose
ø0.157 ø0.114 by shape/
ø3.6 Mounting cap nut opposing faces application
9.5 ø0.142 8 0.315 [Stainless steel (SUS)] A
0.374 19 8 How to read
Joint [Stainless steel (SUS)] 0.315
End bracket 0.748 A Model No.
4.6 0.181 [Stainless steel (SUS)] ø2.2 ø0.087 × 2 Earlier models
2-ø1 ø0.039 vent holes Enclosure [Stainless steel (SUS)] Fixing plug (PA) comparison
Fixing bracket table
Liner + braid tube
[Stainless steel (SUS)] 4 [Brass (Nickel plated)]
0.157 Tube [Stainless steel (SUS)]
5.2 ø2.7 ø0.106 End bracket [Stainless steel (SUS)]
0.205
2-M3 × 0.5 0.020 Fibers
Assembly dimensions with MS-FD-2 (attached mounting bracket) Head [Stainless steel (SUS)]
5 Super
2-M3 × 0.5 0.020 0.197 Holder [Stainless steel (SUS)] Quality
15
0.591 ø4 ø0.157
Threaded
9.5 12.2 Type
0.374 0.480
ø4.6 View A Square Head
10.2 3.3 0.130 ø0.181 Type
4.6 0.402 Emitter / Receiver fiber
0.181 ø1.2 ø0.047 fiber core × 1 Cylindrical
t 1.2 t 0.047 4 4 0.157 Type
0.157 3.3 0.130
6 0.236
14 Sleeve
0.551 Mounting bracket (MS-FD-2)
7 0.276 [Stainless steel (SUS)]
Flat
5.2 Type
0.205
Small
Spot
Note: The FD-H30-KZ1V-S is a set with the FD-H30-KZ1V, photo-terminal,
and atmospheric side fiber. Refer to p.66 for dimensions of the Narrow
Beam
atmospheric side fiber and photo-terminals.
Wide
Beam
FD-H30-L32V-S FD-H35-20S Convergent
Reflective
Type
7 20
3,000 118.110 90 27 1,000 Retroreflective
0.276 0.787 Type
16.7
(0.657 ) 30 1.181
4 0.157
Details of Allowable 3.543 1.063
20
39.370
60 35
bending range
10.75 6.5 11 ø4 ø0.157 sensing part 5 0.787 ø4 30 2.362 1.378 Chemical / Oil-
0.423 0.256 0.433
10 0.197 ø0.157 1.181 16.7 18.3 resistant
ø4 Beam-receiving part: 0.394 10 5 0.657 0.720 ø2.2
(1.2 0.047) 0.197 ø0.087 Heat-
ø0.157 ø50 µm ø1.969 mil × 380 0.394 ø5 ø0.197
ø3.6 Mounting cap nut opposing faces resistant
ø0.142 ø2.9 ø0.114 Resin plug (PA)
19 8 8 0.315 [Stainless steel (SUS)] ø2.1 ø0.083 [Stain- Vacuum-
0.748 0.315 less steel (SUS)] ø10 ø0.394 resistant
Joint [Stainless steel (SUS)] ø3.1 Joint
ø3 ø0.118 ø5 ø0.197
ø0.122 Liquid Leak /
Rod prism (BK7) End bracket M4 × 0.7 0.028 Liner + braid tube [Stainless steel (SUS)] Liquid Detection
[Stainless steel (SUS)] Opposing faces 7 0.276, thickness 2.4 0.094 [Stainless steel (SUS)]
Beam-emitting part:
4 0.157 2-M3 × 0.5 0.020 Liner + braid tube ø50 µm ø1.969 mil × 380 Toothed lock washer ø8.5 ø0.335 [Stainless steel (SUS)]
ø4.6 Enclosure [Stainless steel (SUS)] [Stainless steel (SUS)]
ø0.181 Holder [Stainless steel (SUS)]
Fiber
Options
3.4
5
0.197
(0.134 ) ø2.7 ø0.106
FD-H35-M2
Note: The FD-H30-L32V-S is a set with the FD-H30-L32V, photo-terminal,
and atmospheric side fiber. Refer to p.66 for dimensions of the Details of Heat & cold-resistant Ordinary temperature Semi-custom
atmospheric side fiber and photo-terminals. sensing part specifications specifications fibers
3 22 2,000
Beam-receiving part: 0.118 0.866 78.740
inside diameter ø1.8 ø0.071 150 30 60 ± 5 16.7 18.3
outside diameter ø2.2 ø0.087 5.906 1.181 2.362 ± 0.197 0.657 0.720 Beam-
fiber core bundle × 1 17 5
0.669 0.197 D
receiving Fiber
ø5 ø0.197
side
ø2.2 ø0.087 Dimensions
ø5 ø0.197 Beam- Thru-beam
ø4 ø0.157 ø10 P Type
[Stainless steel (SUS)] [Stainless ø0.394 ø3 ø0.118 emitting
steel (SUS)] side
ø5 ø0.197 (Silicone) Retroreflective
FD-H35-M2S6
M6 × 0.75 0.030 Fixing plug (PA)
[Stainless steel (SUS)] ø3.8 ø0.150 Fixing bracket Type
[Stainless steel (SUS)] [Brass (Nickel plated)] Reflective
Details of Heat & cold-resistant Ordinary temperature
Beam-emitting part:
ø1.3 ø0.051 fiber Opposing faces 10 0.394, thickness 2 0.079 [Stainless steel (SUS)] Type
sensing part specifications specifications core bundle × 1 Toothed lock washer ø11 ø0.433 [Stainless steel (SUS)]
60 22 2,000 Others
ø1.8 ø0.071 fiber
78.740
FD-HF40Y
core bundle × 1 2.362 0.866
emitting and
150 30 60 ± 5 Free-cut
5.906 1.181 2.362 ± 0.197 16.7 18.3
receiving 5
0.197
17
0.669
5 0.657 0.720 <with FX-AT4>
0.197
ø5 ø0.197 Amplifiers
ø5 ø10 ø0.394 2,000
ø2.8 ø0.110 ø0.197
Joint [Brass 500 78.740 FX-500
ø2.2
[Stainless steel (SUS)] ø3 ø0.118
(Nickel plated)] (Silicone) ø0.087 19.685 series
(50)
ø4 ø0.157 (1.969) Protective tube FX-100
ø3.8 ø0.150 Range where cutting is not possible
[Stainless steel (SUS)] Fixing plug (PA) series
[Stainless steel (SUS)] ø1 ø0.039 × 2
M6 × 0.75 0.030 [Stainless steel (SUS)] (0.8) (17) Bending prohibited range
ø5 ø0.197 Fixing bracket (4.44) (0.669) (Polyethylene)
(0.031)
Toothed lock washer [Stainless steel (SUS)] [Brass (Nickel plated)] (0.175) (10) Crimping part
ø11 ø0.433 [Stainless steel (SUS)] Opposing faces 10 0.394, (1.0) (0.394)
(0.039)
thickness 2 0.079 [Stainless steel (SUS)]
INDEX
(ø1.15) (ø4) (ø0.157) Protective tube
(ø0.045) [PFA (fluorine resin)]
62
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Reflective type fibers and reflective type, and in alphabetic order of the Model No.

FD-L10 Free-cut FD-L11 Free-cut


Fiber
Selection <with FX-AT6> <with FX-AT6>
Guide
19 0.748 2,000 78.740 ø0.75 ø0.030 fiber core × 1 (PMMA) 19
Lens (PMMA) Sheath ø1.3 ø0.051 (Polyethylene) 0.748 2,000 78.740 ø0.75 ø0.030 fiber core × 1 (PMMA)
Model 7 0.276 3.5 0.138 3.5 Sheath ø1.3 ø0.051 (Polyethylene)
2 0.079 ø1.3 ø0.051 ø1 ø0.039 Lens (PMMA) 7 0.276
2 0.079 0.138 ø1.3 ø0.051 ø1 ø0.039
Choose
by shape/ Beam-receiving side
application 12 4.5 0.177 (7) (0.276) Beam-receiving side
0.472 12 8 (7) (0.276)
Beam-emitting side 0.472 0.315
How to read ø0.5 ø0.020 fiber core × 1 (PMMA) Beam-emitting side
Model No Slit mask [Stainless steel
(SUS304-CSP-H)] Sheath ø1 ø0.039 (Polyethylene) ø0.5 ø0.020 × 1 fiber core (Acrylic)
Earlier models 2.5 0.6 2.9 Sheath ø1 ø0.039 (Polyethylene)
comparison 0.8 0.031 0.098 2-mounting holes for M3 countersunk head screw 0.024 0.114
table 3 0.118 2-mounting holes for M3 countersunk head screw
Enclosure (PC)
3 0.118 Beam (1.15) (0.045)
axis
Enclosure (PC) (1.15) (0.045)
Fibers
Super
Quality
FD-L12W Free-cut FD-L20H Free-cut
Threaded <with FX-AT4> <with FX-AT4>
Type 7 0.276 14 0.551
0.5 0.020 1,000 39.370 2,000 78.740
Square Head 2.5 0.098 (30) 2.5 0.098
Type 1.5 0.059 (5) (0.197) (1.181)
Cylindrical 18 13 0.512
7.2 2-ø1 ø0.039
Type 0.283 Enclosure 0.709
(PC) (ø2) (ø0.079) Model No. tube (m-PPE)
Sleeve ø0.5 ø0.020 fiber core × 1 (PMMA)

2-ø 0.11
Prism Mounting holes for M2 countersunk head screw
Lens (PMMA) Sheath ø1 ø0.039 (Polyethylene)

ø
3 8
(PC) 2 0.079 2-ø1 ø0.039
Flat Beam axis
Type Enclosure (ABS)

Small 1.5 0.059 ø0.5 ø0.020 fiber core × 1 (PMMA) 6 0.236


0.5 Sheath ø1 ø0.039 (Polyethylene)
Spot 0.020 ø1.6 ø0.063
Narrow
Beam
Wide
FD-L21 Free-cut FD-L21W Free-cut
Beam <with FX-AT4> <with FX-AT4>
Convergent
Reflective 21 0.827 2,000 78.740 21 0.827 2,000 78.740
Type 6.5 7 2-mounting holes for M3 6.5 7 2-mounting holes for M3
3 0.118 2-ø1 ø0.039 3 0.118 2-ø1 ø0.039
Retroreflective 0.256 0.276 countersunk head screw 0.256 0.276 countersunk head screw
Type
Chemical / Oil- 24 16 (19) (0.748) ø0.5 ø0.020 fiber core × 1 (PMMA) 24 16
resistant 0.945 0.630 Sheath ø1 ø0.039 (Polyethylene) 0.630
(19) (0.748) 0.5 ø0.020 × 1 fiber øcore (Acrylic)
0.945 Sheath ø1 ø0.039 (Polyethylene)
Heat-
resistant
FD-L10 Front film (Polyester)
Vacuum- Front film (Polyester) 4 0.157
resistant Enclosure (ABS) Beam axis (2) (0.079)
Beam axis (2) (0.079)
Liquid Leak /
Liquid Detection 4 0.157
Enclosure (ABS)

Fiber
FD-L22A Free-cut FD-L23 Free-cut
Options <with FX-AT5> <with FX-AT5>
29 1.142 2,000 78.740 29 1.142 3,000 118.110
18 0.709 6.5 18 0.709 6.5 2-ø1.3 ø0.051
2-ø1.3 ø0.051 2.5
2.5 0.098 0.256 0.256
0.098
Semi-custom Beam-emitting Beam-emitting
fibers side (Gray) side (Gray)
17 12 (15.3) 18 (16.3) (0.642)
0.669 0.472 10 0.394 (0.602) 0.709
Beam-receiving Beam-receiving
side (Black) (4.8) (0.189) side (Black)
2 0.079 2-mounting holes for M3
Fiber Enclosure (ABS) (4.88) (0.192) countersunk head screw ø0.25 ø0.010 fiber core × 9 (PMMA)
Dimensions 2-mounting holes for M3 ø0.25 ø0.010 fiber core × 9 (PMMA) Sheath ø1.3 ø0.051 (Polyethylene)
Sheath ø1.3 ø0.051 (Polyethylene) 3.8 0.150 Beam axis
countersunk head screw
Thru-beam
Type 3.8 0.150 Beam axis (1.8) (0.071)
Retroreflective Enclosure (PC)
(1.8) (0.071)
Type
Reflective
Type
FD-L30A Free-cut FD-L31A Free-cut
Others
<with FX-AT5> FD-L20H <with FX-AT3>
29 1.142 3,000 118.110 29 1.142 3,000 118.110
18 0.709 6.5 18 0.709 6.5 (2.1) (0.083)
2.5 0.098 0.256 2-ø1.3 ø0.051 3 0.256 2-ø2.2 ø0.087
0.118
Amplifiers Beam-emitting Beam-emitting
side (Gray) side
FD-L11
FX-500 20 (17.3) (0.681) 23.5
series 0.787 0.925 (19.4) (0.764)
Beam-receiving
FX-100 (5.3) (0.209) side (Black)
FD-L21W Beam-receiving
series side
2-mounting holes for M3 ø0.25 ø0.010 fiber core × 9 (PMMA)
countersunk head screw Sheath ø1.3 ø0.051 (Polyethylene) ø1 ø0.039 fiber core × 1 (PMMA)
2-mounting holes for M3 Sheath ø2.2 ø0.087 (Polyethylene)
3.8 0.150 countersunk head screw
Beam axis (1.95) (0.077) ø0.25 ø0.010 fiber core × 16 (PMMA)
4.5 0.177 Sheath ø2.2 ø0.087 (Polyethylene)
FD-L21 Beam axis
INDEX
Enclosure (ABS)
Enclosure (ABS)
(2.3) (0.091)
63
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Reflective type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FD-L32H Free-cut FD-R31G Free-cut


Fiber
<with FX-AT3> FD-R31G outline drawing
<with FX-AT6> Selection
Complete thread 10.8 0.425 or more Cap [Stainless steel (SUS304-CSP)] (ø2) (ø0.079) Model No. tube (m-PPE) Guide
30 1.181 4,000 157.480
6.5 0.256 4.5 0.177 5.5
0.217 8 2,000 78.740 Model
0.315 (30) ø1
3.7 1.7 ø0.039
0.146 0.067 (1.181) Choose
2-ø2.2 ø0.087 Beam-emitting side by shape/
25 (16.7) 3.5 0.138 Beam-receiving side application
(8) (0.315) (0.657) M3 × 0.5 0.020
0.984 11.3 0.445 Sheath ø1.3 ø0.051 How to read
ø1.3 ø0.051 Sheath
12.5 0.492 (Polyethylene) ø1 ø0.039 Model No.
ø1.5 ø0.059 fiber core × 1 (PMMA) 1.8 0.071 (Polyethylene) Earlier models
Enclosure (ABS) Sheath ø2.2 ø0.087 (Polyethylene) ø2.3 ø0.091 comparison
Enclosure [ZDC2 (Nickel plated)] table
Lens (Norbornene resin) 2-ø3.2 ø0.126 mounting holes, ø5.7 ø0.224
15 spot facing, 2.6 0.102 deep Toothed lock washer M3 [Stainless steel (SUS304)]
0.591
7.5 15 0.591
0.295 Hexagon nut M3 [Stainless steel (SUS304)]
7.3
0.287
Fibers
3.8 0.150
3-ø3.2 ø0.126 (0.5 0.020 deep, on both sides) ø6.5 5.5 Super
ø0.256 0.217 Quality
2.1 0.083 Threaded
Type
FD-R32EG,
FD-R32EG outlineFD-R34EG
drawing FD-R33EG
FD-R33EG outline drawing
Square Head
Type
Complete thread Cap [Stainless steel (ø3) (ø0.118) Complete thread Cap [Stainless steel (ø3) (ø0.118) Cylindrical
10.8 0.425 or more (SUS304-CSP)] Model No. tube (m-PPE) 10.8 0.425 or more (SUS304-CSP)] Model No. tube (m-PPE) Type
5.5 8 500 19.685 5.5
0.217 0.315 (1) (0.039) 0.217 8 500 19.685
3.7 1.7 0.067 (30) 6 10.7 3.7 0.315 (1) (0.039) Sleeve
0.146 (1.181) 0.236 0.421 0.146 1.7 0.067 (30) 6 10.7
4.5 5.1 M3 × (1.181) 0.236 0.421
M3 × 3.5 0.138 0.177 0.201 0.5 0.020 3.5 0.138 4.5 5.1 Flat
0.5 0.020 Protective tube 0.177 0.201 Type
11.3 0.445 ø1.6 ø0.063 (Polyolefin) ø2.2 Protective tube
1.8 11.3 0.445 ø2.2
12.5 0.492 ø0.087
0.071 12.5 0.492
ø1.2 ø0.047 (Polyolefin) ø0.087 Small
Enclosure [ZDC2 (Nickel plated)] Spot
Enclosure [ZDC2 (Nickel plated)]
1.8 0.071 Toothed lock washer M3
ø2.3 [Stainless steel (SUS304)] ø2.3 ø0.091 Toothed lock washer M3 [Stainless steel (SUS304)] Narrow
ø0.091 Hexagon nut M3 Hexagon nut M3 Beam
Resin plug (ABS)
[Stainless steel (SUS304)] Resin plug (ABS)
[Stainless steel (SUS304)] Wide
Beam- Beam- Beam
3.8 0.150 3.8 0.150 receiving
receiving
side side Convergent
ø6.5 5.5 ø6.5 5.5 Reflective
ø0.256 0.217 ø0.256 0.217 Beam-
Beam- emitting Type
emitting side
2.1 0.083 7 side 7 Retroreflective
11 0.433 0.276 2.1 0.083 Type
11.6 0.457 11.6 0.457 11 0.433 0.276
Chemical / Oil-
FD-R41 Free-cut FD-R60 Free-cut resistant

<with FX-AT5> <with FX-AT3> Heat-


resistant
Complete thread 6.5 0.256 or more Cap [Stainless steel (SUS304-CSP)] 2,000 78.740 Vacuum-
25 0.984
7 9 2,000 78.740 20 0.787 resistant
0.276 0.354
FD-L32H 2 2-ø2.2 ø0.087 Liquid Leak /
5.2 (30) Liquid Detection
0.205 0.079 (1.181)
2.4 0.094 3.5 0.138 (30)
Fixing bracket (1.181)
7 0.276 (ø2.5) (ø0.098) [Stainless steel (SUS303)] (ø3.2) (ø0.126) Model No. tube (m-PPE)
ø1.2
Model No. tube (m-PPE) R5±1
10 0.394 M6 × 0.75 0.030
Hexagon nut M6
ø0.047 R0.197±0.039 ø5 ø0.197 Fiber
M4 × 0.7 0.028 Enclosure [ZDC2 (Nickel plated)] [Stainless steel Options
ø3 ø0.118 Toothed lock washer M4 (SUS304)] 5 0.197
[Stainless steel (SUS304)] ø1 ø0.039 fiber core × 1 (PMMA)
Toothed lock 13 Sheath ø2.2 ø0.087 (Polyethylene)
Hexagon nut M4 washer M6 0.512
ø1.2 ø0.047 Stainless steel pipe
[Stainless steel (SUS304)] 2 [Stainless steel 90°±5
[Stainless steel (SUS304)]
Semi-custom
(SUS304)]
0.079 fibers
4.2 0.165 ø1.3 ø0.051 ø4.5 End bracket [Stainless steel (SUS303)]
ø0.177 -0.1 -0.004 2 0.079
ø6 ø0.236-0.13 -0.005 5 0.197
ø8.5 ø0.335 7 0.276 Mounting reference
surface ø11 ø0.433
(Screw periphery) Fiber
3 ø0.75 ø0.030 fiber core × 1 (Acrylic)
10 0.394 Dimensions
0.118 Sheath ø1.3 ø0.051 (Polyethylene)
Thru-beam
Type
Retroreflective
FD-R61Y Free-cut FD-S21 Type
<with FX-AT3> Reflective
Type
(Set screw tightening range) 2-ø2.2 ø0.087
4 0.157 5.1 0.201
(30) Others
(1.181)
7 mm 0.276 in or more Cap [stainless steel (SUS304-CSP)] ø1 ø1
(complete thread) 11 ø0.039 ø1.5 ø0.059 ø0.039 (ø2.5) (ø0.098)
0.433 2,000 78.740 4.5 0.177
10 5 2 8 1,000 39.370
0.394 2-ø2.2 ø0.087 0.079 0.315 (1) (0.039) 6 10.7
0.197 0.236 0.421 Amplifiers
5.5 (3.1) (0.122)
0.217
7 11 11.6 FX-500
Head [stainless steel (SUS304)]
8 0.315 0.276 0.433 0.457 series
Sheath
Toothed lock washer M6 [stainless steel (SUS304)] ø1 ø0.039 FX-100
2 0.079 Hexagon nut M6 [stainless steel (SUS304)] Details of (Polyethylene) Resin plug (ABS) series
M6 × 0.75 0.030 End bracket (ø2.5) (ø0.098) Model No. tube (m-PPE)
sensing part [Stainless steel (SUS303)]

10
ø11 ø0.433 0.394
ø1.0 ø0.039 fiber core × 1 (PMMA) INDEX
Outer sheath ø2.2 ø0.087 [PFA (Fluorine resin)]
Inner sheath ø1.8 ø0.071 (Polyethylene)
ø0.25 ø0.010 fiber core × 2 (PMMA)
(each beam-emitting part and beam-receiving part)
64
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough Dimensions are listed in the order of thru-beam type, retroreflective type,
Fiber Reflective type fibers and reflective type, and in alphabetic order of the Model No.

FD-S30 FD-S31 Free-cut


Fiber
Selection <with FX-AT2> <with FX-AT4>
Guide
2 2,000 2
Model 0.079 8 78.740 0.079
(19.7) (0.776) 8 2,000
Set screw 4 0.315 Resin plug (ABS) 78.740
10.2 0.402 0.315
Choose tightening range 0.157 (20) 4 0.157 (Set screw tightening range) ø1
by shape/ ø2 (0.3) (0.012)
ø0.079 (0.787) (30) ø0.039
application ø2.2 ø2
ø0.087 ø0.079 (1.181)
How to read
Model No
Earlier models
comparison ø3 ø0.118 -0.07 -0.003 ø1 (ø4.33) (ø0.170)
-0.10 -0.004 ø1.8
table
Mounting reference surface ø0.039 (ø2) (ø0.079) Model No. tube (m-PPE) ø3 ø0.118 -0.07 -0.003 (ø2) (ø0.079) Model No. tube (m-PPE)
ø0.071 -0.1 -0.004
(Periphery) Mounting reference surface (Periphery) ø0.5 ø0.020 Fiber core × 1 (Acryic)
Sheath ø1 ø0.039 (Polyethylene)
End bracket [Stainless steel (SUS303)] End bracket [Stainless steel (SUS303)]

Fibers
FD-S32 Free-cut FD-S32W Free-cut
Super
Quality <with FX-AT5> <with FX-AT5>
Threaded
Type 2.7 2.7 15 0.591 2,000 78.740
0.106 2,000 78.740 0.106
Square Head 15 0.591 (30) (1.181)
(30) 7
Type 7 (1.181)
2-ø1.3 ø0.051 0.276
0.276 2-ø1.3 ø0.051
Cylindrical
Type
ø3 ø0.118
(ø2.5) (ø0.098) Model No. tube (m-PPE)
Sleeve ø3 ø0.118 End bracket
(ø2.5) (ø0.098) Model No. tube (m-PPE) [Stainless steel ø1 ø0.039 fiber core × 1 (PMMA)
End bracket
Flat [Stainless steel ø1 ø0.039 fiber core × 1 (PMMA) (SUS303)] Sheath ø1.3 ø0.051 (Polyethylene)
Type (SUS303)] Sheath ø1.3 ø0.051 (Polyethylene)
Small
Spot
Narrow
Beam
Wide FD-S33GW Free-cut FD-S60Y Free-cut
Beam
<with FX-AT6> <with FX-AT5>
Convergent
Reflective
Type 15 0.591 2,000 78.740 2,000 78.740
Retroreflective 7 (30) (1.181) 1,500 59.055
Type 0.276 ø1 ø0.039 16 ø4 ø0.157
Beam-emitting 0.630
Chemical / Oil- side
resistant ø1.3 ø0.051
ø5.5
ø0.217
Heat- Beam-receiving
resistant ø3 ø0.118 side Protective tube
End bracket (ø2) (ø0.079) Model No. tube (m-PPE) [PFA (Fluorine resin)] 2-ø1.3 ø0.051
Vacuum- [Stainless steel FD-S32W
resistant (SUS303)]
Sheath ø1 ø0.039 (Polyethylene) Cover [PFA (Fluorine resin)]
Details of Sheath ø1.3 ø0.051 (Polyethylene)
Liquid Leak / sensing part
Liquid Detection ø1.0 ø0.039 fiber core × 1 (PMMA)
2.7 Outer sheath ø1.3 ø0.051 (Polyethylene)
0.106

Fiber Beam-receiving ø0.25 ø0.010 fiber core × 9 (PMMA)


FD-S32
Options
Beam-emitting ø0.5 ø0.020 fiber core × 1 (PMMA)

Semi-custom
fibers
FD-V30 Free-cut FD-V30W Free-cut
<with FX-AT4> <with FX-AT4>
10 Set screw tightening range 10 Set screw tightening range
Fiber 2.8 0.110 0.394 2.8 0.110 0.394
Dimensions
Thru-beam Beam Beam
Type axis axis
15 0.591 15 0.591 2,000 78.740 15 0.591 15 0.591 2,000 78.740
Retroreflective (30) (1.181) 2-ø1 ø0.039
2-ø1 ø0.039
Type ø1.5 ø3 ø0.118 (30) (1.181)
ø0.059 ø1.5
A A ø0.059 ø3 ø0.118
Reflective
Type
Sleeve [Stainless Sleeve [Stainless End bracket
Others steel (SUS303)] (ø2) (ø0.079) Model No. tube (m-PPE) steel (SUS304)] [Stainless steel (ø2) (ø0.079) Model No. tube (m-PPE)
End bracket (SUS303)]
[Stainless steel ø0.5 ø0.020 fiber core × 1 (PMMA) ø0.5 ø0.020 fiber core × 1 (PMMA)
View A (SUS303)] Sheath ø1 ø0.039 (Polyethylene) View A Sheath ø1 ø0.039 (Polyethylene)
2 0.079 2 0.079
2.5 0.098 2.5 0.098
Amplifiers 1.3 0.051
1.3 0.051
FX-500
series Shielding plate (Polyester)
Shielding plate (Polyester)
FX-100
series

INDEX

FD-S33GW
65
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Dimensions are listed in the order of thru-beam type, retroreflective type, Tough
Reflective type fibers and reflective type, and in alphabetic order of the Model No. Fiber

FD-V50 Free-cut FD-Z20HBW Free-cut


Fiber
<with FX-AT3> <with FX-AT4> Selection
Guide
10 Set screw tightening range 10 0.394 1,000 39.370
4.5 0.177 0.394 0.5 0.020 2 ø2.2 ø0.087 hole, ø3.6 ø0.142 Model
0.079 3.5 0.138 spot facing, 1.4 0.055 deep
1.05 0.041 2.5 0.098
2.2 4-R1 R0.039 (30) 2-ø1 Choose
0.087 ø0.039 by shape/
Beam (1.181) application
axis 5 0.197 10 4 0.157
20 0.787 15 0.591 2,000 78.740 0.394 How to read
(30) (1.181) 2-ø2.2 ø0.087 (2.2) (0.087) (ø2) (ø0.079) Model No. tube (m-PPE) Model No.
Inner pipe
A ø5 ø0.197 ø1.5 [Stainless steel (SUS304)] Earlier models
ø2 ø0.079 ø0.059 Enclosure (PC) comparison
7 1 0.039 table
0.276 2.1 0.083

Sleeve [Stainless Beam axis ø0.5 ø0.020 fiber core × 1 (PMMA)


End bracket 0.6 0.024 Sheath ø1 ø0.039 (Polyethylene)
steel (SUS304)] [Stainless steel (ø3.2) (ø0.126) Model No. tube (m-PPE)
(SUS303)] ø0.75 ø0.030 fiber core × 1 (PMMA) Fibers
Sheath ø2.2 ø0.087 (Polyethylene)
View A Super
Quality
2.3 0.091
3 0.118 Threaded
Type
1.7 0.067
Square Head
Type
Shielding plate
(Polyester) Cylindrical
Type

FD-Z20W Free-cut FD-Z40HBW Free-cut Sleeve

<with FX-AT4> <with FX-AT5> Flat


Type
ø3.2 ø0.126 hole, ø5.6 ø0.220
7 1,000 39.370
spot facing, 2.2 0.087 deep 11 0.433 Small
0.276 2,000 78.740 Spot
0.5 3.5 0.138 ø2.2 ø0.087 hole, ø3.6 ø0.142 3.5 4-R1 R0.039
0.020 2 0.079 spot facing, 1.4 0.055 deep 1 3.5 0.138 0.138
1.2 0.047 0.039 1.05 0.041 Enclosure (PC) Narrow
2.5 0.098 4-R1 R0.039 Beam
2-ø1 (30) 2-ø1.3
(30) (1.181) ø0.039 3.5 0.138 (2.2)
2.2 0.087 ø0.051
10 7 14 6.5 0.256 (0.087) (1.181) Wide
5 0.197 0.394 4 0.157 0.276 0.551 Beam
(ø2) (ø0.079) Model No. tube (m-PPE)
(ø2.5) (ø0.098) Model Convergent
2.2 0.087 2.7 Reflective
Inner pipe [Stainless steel (SUS304)] ø2.4 ø0.094 0.106 No. tube (m-PPE)
ø1.5 Prism 7 Type
ø0.059 (PMMA) Enclosure (PC) 0.276 1.6 0.063
Inner pipe Retroreflective
Beam axis 1.05 0.041 FD-Z20HBW [Stainless steel (SUS304)] Type
Beam axis ø1 ø0.039 fiber core × 1 (PMMA)
0.9 Sheath ø1.3 ø0.051 (Polyethylene) Chemical / Oil-
ø0.5 ø0.020 fiber core × 1 (PMMA) 0.035 resistant
Sheath ø1 ø0.039 (Polyethylene)
Heat-
resistant
Vacuum-
FD-Z40W Free-cut FD-Z50HW Free-cut resistant
Liquid Leak /
<with FX-AT5> <with FX-AT3> Liquid Detection
7 1 0.039
0.276 2,000 78.740 Lens (BK7) 15 2,000 78.740
3.5 0.138 ø3.2 ø0.126 hole, ø5.8 ø0.228 0.591
1.2 0.047 spot facing, 2.2 0.078 deep
1 3.5
0.039 0.138 4-R1 R0.039 4.6 0.181 9.5 0.374 Fiber
3.5 0.138 (30) (1.181)
2-ø1.3 Options
ø0.051
7 14 6.5 Enclosure (PC) 2-ø2.2
0.276 0.051 0.256 ø0.087

2.2
(ø2.5) (ø0.098) Model No. tube (m-PPE) 5.2 0.205
ø2.4 ø0.094 0.087 Inner pipe [Stainless steel (SUS304)] Beam axis ø1 ø0.039 fiber core × 1 (PMMA) Semi-custom
Prism (PMMA) Enclosure (PC) Sheath ø2.2 ø0.087 (Polyethylene) fibers
Beam axis 1.05 0.041
Assembly dimensions with MS-FD-2 (attached mounting bracket)
ø1 ø0.039 fiber core × 1 (PMMA) Lens (BK7) 15 1 0.039
0.591 2,000 78.740 Fiber
Sheath ø1.3 ø0.051 (Polyethylene) 2-M3 × 0.5 0.020
Dimensions
9.5 12.2 0.480
0.374 4.6 0.181 Thru-beam
Type
10.2 Retroreflective
0.402 4 0.157 3.3 0.130 Type
5 0.197
3.3 0.130 MS-FD-2 Mounting bracket Reflective
4 0.157 [Stainless steel(SUS304)] Type
1.2 0.047 14 0.551 2-ø2.2
FD-V50 6 Enclosure (PC) ø0.087 Others
0.236 7 0.276
5.2 0.205
Beam axis FD-Z40HBW ø1 ø0.039 fiber core × 1 (PMMA)
Sheath ø2.2 ø0.087 (Polyethylene)

Amplifiers

FR-Z50W FX-500
series
FX-100
series

INDEX
66
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough
Fiber Vacuum-resistant Atmospheric side fiber

FT-J8 Free-cut
Fiber (Accessory for vacuum-resistant fiber) <with FX-AT3>
Selection
Guide
Photo-terminal side Amplifier side
Model 2,000 78.740

Choose 10
by shape/ 0.394 ø3.6 11 ø2.2
application 4 0.157 ø0.142 0.433 ø0.087
How to read
Model No
ø4 Mounting cap nut opposing faces 8 0.315
Earlier models ø0.157 [Stainless steel (SUS)]
comparison
table Joint [Brass (C3604) (Nickel plated)]

Fibers
Super
Quality
Threaded
Type
Square Head
Type FB-1 Fiber bender (Optional) FTP-□  FDP-□ Protective tube (Optional)
Cylindrical
Type
52
2.047 FTP-□, FDP-N□
40 L
Sleeve 1.575 15 15 ø15
0.591 0.591 ø0.591
3
Flat 20 0.118
Type 0.787
Small 8.6
Spot 0.341
Narrow ø4.5 ø0.177 spiral tube
Beam [Stainless steel (SUS)]
M8 × 1 0.039 thread
Wide Material: PP (Containing steel blade) ø6 ø0.236 [Brass (Nickel plated)] [Brass (Nickel plated)]
Beam M4 × 0.7 0.028 internal thread, 5 0.197 deep
Convergent FV-BR1 Photo-terminal (for vacuum-resistant) (with vacuum-resistant fiber)
Reflective
Type FTP-N□ L
36 15 15 ø11
Retroreflective 1.417 0.591 2 0.591 ø0.433
Type 6 5 14 0.079
Mounting hole 0.236 0.197 0.551
Chemical / Oil-
resistant Chamber wall or flange 2
0.079
Heat- ø3.8 ø0.150 spiral tube
resistant Hole
[Stainless steel (SUS)]
ø5 ø0.197 [Brass (Nickel plated)] M6 × 0.75 0.030 thread
Vacuum- ø5.5 to ø6.0 [Stainless steel (SUS)]
resistant ø0.217 to ø0.236 O-ring M5 × 0.8 0.031 thread M3 × 0.5 0.020 internal thread, 5 0.197 deep

Liquid Leak / M5 × 0.8 0.031 thread Spring washer ø10 ø0.394


Liquid Detection [Stainless steel (SUS)] Opposing faces 8 0.315, thickness 3 0.118 FDP-□
ø18
L
15 15 ø0.709
FV-LE1 Vacuum-resistant expansion lens (Optional) 0.591 3 0.591
0.118
Fiber 9.2
0.362
Options 6 3.7
0.236 0.146
4
0.157 ø7 ø0.276 spiral tube
[Stainless steel (SUS)]
ø4 3.7
Semi-custom ø0.157 0.146 ø8 ø0.315 [Brass (Nickel plated)] M10 × 1 0.039 thread
fibers M6 × 0.75 0.030 internal thread, 5 0.197 deep [Brass (Nickel plated)]
ø3.6 ø0.142 lens
ø1 ø0.039 vent hole M2.6 × 0.45 0.018 internal
thread, 3 0.118 deep
• Length L
Fiber Material: Enclosure........Aluminum alloy Model No. Length L
Dimensions (A6061-T6)
Lens...............BK-7 FTP-500, FTP-N500, FDP-N500, FDP-500 500 +100 19.685 +0.394
0
Thru-beam
Type
FV-SV2 Vacuum-resistant side-view lens (Optional) FTP-1000, FTP-N1000, FDP-N1000, FDP-1000 1,000 +100 39.370 +0.394
0
Retroreflective
Type FTP-1500, FTP-N1500, FDP-N1500, FDP-1500 1,500 +100 59.055 +0.394
0
Reflective
Type Enclosure Heat resistant adhesive
[Stainless steel (SUS)]
Others 4.5
9.5 0.374
Lens (BK7) 7.3 0.287 2-ø3.1 ø0.122
0.177 3.6
0.142

4.7 2.8 0.110


0.185 6.6
Amplifiers 10.5
0.260
5.5
0.413 0.217
FX-500
series
FX-100
series
ø1 ø0.039 vent hole M2.6 × 0.45 0.018,
3.6 3.2 0.126 deep
0.142

INDEX
67
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Tough
FX-AT2 Attachment for fixed-length fiber (Accessory for fixed-length fiber) FX-AT3 Attachment for ø2.2 mm ø0.087 in fiber Fiber

8
(Accessory for ø2.2 mm ø0.087 in fiber)
6 0.315 9.1
0.236 0.358
2-ø2.3 8.2 Fiber
ø0.091 7.5 0.323 Selection
0.295 Guide
4 5
7 13 14 0.197
0.276 0.512 0.551
0.157 Model
Choose
7 11.2 16 by shape/
0.276 0.441 0.630 application
Material: POM 7 How to read
0.276 Material: Polycarbonate
Model No.
Earlier models
comparison
table

FX-AT4 Attachment for ø1 mm ø0.039 in fiber FX-AT5 Attachment for ø1.3 mm ø0.051 in fiber
(Accessory for ø1 mm ø0.039 in fiber) (Accessory for ø1.3 mm ø0.051 in fiber) Fibers
20.5 20.5
0.807 6.5 0.807 6.5 Super
3 3.5 3 3.5 0.256 Quality
0.118 0.138 2 0.256 ø1.1 0.118 0.138 2 ø1.4
4 ø2.2 0.079 ø0.043 4 ø2.2 0.079 ø0.055 Threaded
0.157 ø0.087 0.157 ø0.087 Type
ø1.1 ø1.4
5 0.197 ø0.043 5 0.197 Square Head
ø0.055
15 7 15 7 Type
Material: 0.591 0.276 0.591 0.276
Cylindrical
Holder.....PA (Nylon 66) 5 0.197 1.7 5 0.197 1.7 Type
Ground...POM 0.067 0.067
ø2.2 ø2.2
ø0.087 Material: Holder..............PA (Nylon 66) ø0.087 Sleeve
Ground.............POM
Flat
Type
Small
FX-AT6 Attachment for ø1 mm ø0.039 in / ø1.3 mm ø0.051 in mixed fiber FX-CT2 Fiber cutter (Accessory for free-cut type fiber) Spot
(Accessory for ø1 mm ø0.039 in / ø1.3 mm ø0.051 in mixed fiber) Narrow
Beam
20.5 14.6
0.807 6.5 0.575 Wide
3 3.5 0.256 45 8 Beam
0.118 0.138 2 ø1.1
ø2.2 0.079 ø0.043 1.772 0.315 Convergent
4
ø0.087 Reflective
0.157 Type
ø1.4
5 0.197 ø0.055 Retroreflective
15 7 25 Type
0.591 0.276 0.984
5 0.197 Chemical / Oil-
1.7 resistant
0.067
ø2.2 Heat-
Material: H
 older..............PA (Nylon 66) ø0.087 Material: ABS resistant
Ground.............POM
Vacuum-
resistant

FX-LE1 Expansion lens (Optional) FX-LE2 Super-expansion lens (Optional) Liquid Leak /
Liquid Detection

ø4 Lens 22.2
ø0.157 0.874
17
0.669 Fiber
9.2 Knurled surface 8 Options
ø9
0.362
ø0.354 5 0.315 6
0.197 0.236
ø4.3 ø12 ø10.2 ø7
ø0.169 M2.6 × 0.45 0.018 internal ø0.472 ø0.402 ø0.276 Semi-custom
Material: Enclosure............ Brass thread, 3 0.118 deep fibers
(Nickel plated)
M4 × 0.7 0.028 internal
Lens.................... Glass thread, 6 0.236 deep
Material: Enclosure............ Stainless steel (SUS303)
Lens.................... Glass Fiber
Dimensions
Thru-beam
Type
FX-MR1 Pinpoint spot lens (Optional) FX-MR2 Zoom lens (Optional) Retroreflective
Type
Lens 27.1 Reflective
Lens Effective dia.: Mounting drawing 1.067 Type
ø4 ø3.3 ø0.130 20 7
ø0.157 with FD-42G 0.787 4.5 0.276
Others
0.177
ø7.1 ø8
ø0.280 ø0.315
20.2 ℓ = 36 to 37
0.795 1.417 to 1.457
11
0.433 Note: In order to obtain a ø0.5 mm M4 × 0.7 0.028 internal Amplifiers
ø0.02 in spot, it is necessary to keep thread, 6 0.236 deep
FX-500
ø6
M4 × 0.7 0.028 internal “ ℓ ”, in the above figure, within the series
thread, 6 0.236 deep specified range. Material: Enclosure............ Aluminum (Black ALMITE)
ø0.236
Lens.................... Glass FX-100
Material: Enclosure............ Aluminum (Black ALMITE) series
Lens.................... Glass

INDEX
68
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
New product
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough
Fiber FX-MR3 Finest spot lens (Optional) FX-MR5 Zoom lens (Optional)

Mounting drawing with FD-EG30 6.3


Fiber 0.248 ø5 ø0.197
Selection lens 10.3
Guide 0.406

Model 15
0.591 ℓ = 27.5 1.083 3.3 20.3
Choose 0.130 0.799
by shape/ 5 4
application 0.197 0.157 8 0.315
How to read 3 0.118 2-M3 × 0.5 0.020
ø4 ø0.157 M3 × 0.5 0.020 4.5 0.177 2.5
Model No thru-hole threads
internal thread 0.098 7
Earlier models
comparison Knurled 0.276
table
Material: E
 nclosure............ Aluminum (Black ALMITE)
Lens.................... Glass M4 × 0.7 0.028 internal
3.15 thread, 11 0.433 deep
0.124
Note: When inserting the fiber, insert fully till it stops. Material: Enclosure............ PBT (Black)
Lens.................... Glass
Fibers
NT-FX-MR5 (exclusive nut) is attached.
Super
Quality
Threaded
Type FX-MR6 Finest spot lens (Optional) FX-MR7 Finest spot lens (Optional)
Square Head
Type Mounting drawing with FD-EG31 Caulking part 15.3
0.602
Cylindrical 5
Type M3×0.5 0.020
0.197

Sleeve ø4.3 ø5
ℓ = 28.5 1.122 ø0.169 ø0.197
Flat Lens Flat knurl M3 × 0.5 0.020
Type Holder [Stainless steel
ø4 ø5 ø0.197 Lens (Acrylic) (SUS303)] Laurette of straight pattern
Small ø0.157
Spot 5
Narrow 0.197
Beam
16 Mounting drawing with FD-R31G/R32EG/R33EG/R34EG
0.630
ℓ=27.8 1.094
Wide
Beam Material: Enclosure............ Aluminum (Black ALMITE)
Lens.................... Acrylic
Convergent
Reflective Note: When inserting the fiber, insert fully till it stops.
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
resistant FX-MR8 Zoom lens (Optional) FX-MR9 Parallel light lens (Optional)
Vacuum-
resistant Caulking part Caulking part
15 10
Liquid Leak / 0.591 0.394
Liquid Detection 5 5 M3×0.5 0.020
M3×0.5 0.020 0.197
0.197
ø4.3 ø5 ø4.3 ø5
ø0.169 ø0.197 ø0.169 ø0.197

Fiber Holder [Stainless steel


Options Holder [Stainless steel
Lens (BK7) (SUS303)] Laurette of straight pattern
Lens (BK7) (SUS303)] Laurette of straight pattern

Semi-custom Mounting drawing with FD-R31G/R32EG/R33EG/R34EG Mounting drawing with FD-R31G/R32EG/R33EG/R34EG


fibers ℓ=22.8 to 27.5 ℓ=22.5 0.886
0.898 to 1.083

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
69
Refer to the FX-500 series (p.96), FX-100 series (p.110) for dimensions of the amplifiers.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. New product
introduction
Tough
FX-SV1 Side-view lens (Optional) MS-EX3 Mounting bracket for FX-MR2 (Accessory for FX-MR2) MS-FD-2 Fiber mounting bracket Fiber

0.5 4
Accessory for FD-Z50HW, FR-KZ50E/KZ50H/Z50HW, FD-H30-KZ1V-S
0.020 0.157 2-M3 × 0.5 0.020
ø4
ø0.157 Fiber
Rod prism Selection
8.7 0.343 9.8 12.2 4 3.3
Guide
0.386 0.480 0.157 0.130
8 Knurled surface 10.2 Model
0.8 8.5 4.9 0.402
0.315 2.5 0.031 0.335 Anti-slip rubber sheet (8 × 9.5 × 1) 0.193 Choose
0.098 2-ø3.5 ø0.138 mounting holes (0.315 × 0.374 × 0.039) 5 4
0.197 3.3 0.157 by shape/
t1.2 0.130 application
6 7
M2.6 × 0.45 0.018 internal 10 0.236 How to read
0.394 0.276
thread, 3 0.118 deep Model No.
16 Earlier models
0.630 14 comparison
Material: Enclosure............ Brass (Nickel plated) 23 0.551 table
Lens.................... Glass 0.906 Material: Brass (Nickel plated) Material: Stainless steel (SUS304)

Fibers
MS-FD-3 Fiber mounting bracket RF-003 Reflector for FR-KZ50E/KZ50H Super
Accessory for FT-KV40/FT-KV40W Accessory for FR-KZ50E/KZ50H Quality

10.1 10.6 Threaded


(11) Type
(0.433) 5 0.398 0.417 10 0.394
3.3 0.130 3.3 0.130 0.197 (Effective reflector width) Square Head
3.2 3-R0.5 R0.020 (2-R)
C1 C0.039 0.126 Type
(2-R) Cylindrical
5 0.197 5 19 1.1 10 0.394 19 28
0.197 10 Type
0.748 0.043 (Effective reflector width) 0.748 1.102
0.394
Sleeve
R2.5 R0.098
R1.6 3.2 0.126
R0.063 3.2 1 0.039 Flat
0.126 Type
Cover 4.3 Reflector
3.9 0.154 [Stainless steel (SUS304)] 0.169 (Norbornene resin) Small
(88°) (88°) Spot
(90°) (90°)
Narrow
3.5 0.138 Beam
0.4 6.9 6.9 Wide
0.272 0.272 Beam
0.016
Material: Stainless steel (SUS304) Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
RF-13 Reflective tape for FR-Z50HW RF-210 Reflector (Optional) resistant
Accessory for FR-Z50HW Heat-
33.3 resistant
0.5 30 1.311
0.020 1.181 Vacuum-
resistant
12.8
0.504 Liquid Leak /
30 Liquid Detection
Rear surface 1.181 M3 nut mounting holes
(Pressure-sensitive Reflector (for mounting at the back)
adhesive)
11
Reflective surface (Acrylic) 0.433 Base Fiber
Options
Material : Acrylic (Reflective surface) 2-ø3.4 ø0.134 thru-holes
3.2 (for mounting at the side)
0.126 25
0.984
10 2-ø3.4 ø0.134 holes,
0.394 6 0.236 deep Semi-custom
(for mounting at the back) fibers

2-M3 nut mounting holes


(for mounting at the side) Fiber
Material: A
 crylic (Reflector) Dimensions
ABS (Base)
Thru-beam
Two M3 (length 8 mm 0.315 in) screws with washers and two nuts are attached. Type
Retroreflective
RF-220 Reflector (Optional) RF-230 Reflector (Optional) Type
Reflective
Type
35.3 50.3
1.390 1.980 Others

34.3
42.3 1.350
1.665 49.3 Amplifiers
(21)
(0.827) 59.3 1.941
2.335 FX-500
8 0.315 (30) series
4 0.157 (1.181)
3.3 FX-100
0.130 series
10
25 2-ø3.6 ø0.142 0.394 5 0.197
mounting holes 8.3
0.984 0.327 3.3
2-ø4.6 ø0.181 0.130
Material: Acrylic (Reflector) 40 mounting holes INDEX
ABS (Base) 1.575 8.3
0.327
Material: Acrylic (Reflector)
ABS (Base)
70
Digital Fiber Sensor
FX-500 SERIES Ver.2
New product
introduction
Tough
Fiber

Fiber
Selection
Guide
At the industry’s leading edge
Model
Choose
by shape/
application
How to read Conforming to
Model No Ver.2 EMC Directive
Listing

Earlier models
comparison
table

Certified

Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type PNP output Timer Interference Light intensity
type available prevention monitor
Sleeve

Flat * There is no change in Model No. and price due to version upgrade.
Type * Cover opened state is shown.

Small Automatic Test input External sync.


Spot sensitivity setting

Narrow Improved the operability and visibility of the operation keys


Beam
Wide Operation keys (setting switch and MODE key) have been renewed to be easy to operate. Also, the color of the keys
Beam
Convergent
has been changed from black to light gray to achieve good visibility in dim light.
Reflective
Type
Retroreflective Previous Upgraded (Ver. 2)
Type
Chemical / Oil-
resistant Setting switch MODE key Setting switch MODE key
Heat- Clicking touch!
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

High stability!
Semi-custom
fibers When the FX-500 series is used together with our super quality fiber, the incident light intensity variation among units
is decreased to only 1/4 of that of conventional models.
By being close to absolute values instead of modified digital values, changes in detection that could not be found in
the past can now be monitored.
Fiber
Dimensions
Thru-beam Super quality fiber FX-500 series
Type Incident light intensity
Retroreflective Incident light
Type Threshold Incident light
value intensity intensities are
Reflective stable.

1/4
Type
Can control by
Others Unify the threshold value
incident light using just one
intensity variation threshold value.
[from previous]

Amplifiers
FX-500 Threshold Incident light
series value intensity Incident light intensity
Previous amplifier
L D

FX-100 MODE

series Large variation in


Variation in the threshold value incident
L D
MODE
light intensity.

L D
Requires setting
MODE
different
INDEX threshold values
L D for each sensor.
MODE
71

A quality that surpassed that of standard fibers! New product


introduction
New fibers developed using a new manufacturing method adopted by our own factory along with a persistent quality Tough
control system. Fiber
The basic performance of a standard fiber is greatly enhanced!

Fiber
Selection
Guide

Model
Choose
Stable emission amount ± 10 ø2.2 mm ø0.087 in standard fiber by shape/
application
How to read

New material
Variation in emission amount of the fiber core
Model No.

Previous
is controlled down to less than ±10 %,
Earlier models
achieving a stable detection. comparison
• Beam axis deviation: Thru-beam type within ±2 °, table
Reflective type within ±3 ° Single core standard fiber In general, high-flexibility
• Beam axis centering precison: within ± 150 μm with high flexibility types adopt a multi-fiber core,
which may result in large
variation in light emission.
Fibers
Expanded temperature range More flexible! R4 Super
Quality
Ambient temperature [–40 to +70 °C –40 to +158 °F in previous model] Bending radius [Previous model is R25 mm R0.984 in] Threaded
Type

– 55 to +80 °C 1.2 times


more than
R4 mm 1/6
of that of
Square Head
Type

– 67 to +176 °F previous model


R0.157in previous model Cylindrical
Type

Sleeve
Integrated high-precision plug More bendable! Flat
Type
The centering precision of Bending durability [Previous model is 1,000 times] Small
the fiber core attached to the Spot
inserting plug is doubled.
As the insertion precision is 10 million 10,000 times Narrow
Beam
increased, the variation among
units can be greatly suppressed.
times more than previous model
Wide
* Bending conditons Beam
• Centering precision: within ± 40 μm Bending radius: R10 mm R 0.394 in, Convergent
Reciprocating bending 180° Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
H y p e r resistant
Max. 25 μs response time HYPR mode incorporated Vacuum-
resistant
FX-500 with its high response time contributes to FX-500 in combination with small diameter fibers which Liquid Leak /
Liquid Detection
improve productivity. can handle challenging detections, allows long sensing
range.

FX-500
7RXJK
FD-41
Max.
5.7 times! (Note)
longer than the previous model
Fiber
Options

HYPR mode

Previous FD-NFM2 Semi-custom


FX-301 (LONG mode)
fibers

Performing minute object detection when using a small Note: When using FD-NFM2.
diameter fiber is now possible with a high response time
Fiber
and longer sensing range. Dimensions
Thru-beam
Type

So accurate! Sharp detection with suppressed hysteresis Retroreflective


Type
Reflective
FX-500 with its • Long range detection of small objects with small • Highly accurate detection while Type
accurate detection difference in light intensity H-02 mode avoiding saturation H-01 mode Others
catches fractional
differences in
light intensity, achieving
high precision and
Amplifiers
solving low-hysteresis
applications. FX-500
series
FX-100
Retroreflective
FR-Z50HW series
type fiber

INDEX
FT-A11
Reflector
72

New product Flat display with wide viewing angle


introduction
Tough The large and high-contrast 7-segment display of high Pr
ev
Fiber luminance provides clear visibility from a wide angle of i ou
s
view. sp

ac
e
re
Fiber

qu
Selection

i re
Guide

me
Compact cover does not get in the way
Model

nt
Choose
Reduced to 1/3 of the previous model’s size
by shape/
application Clearly visible even
How to read from sideways
Model No
Earlier models
comparison
table
R23 mm
R0.906 in
Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type

Sleeve
Resolves variation in displayed incident light
intensity Display
Flat adjustment
Type Display adjustment setting setting
Small
Spot
The variation in display can be adjusted to random
Narrow values. This helps to define proper instruction in a work
Beam
Wide
order.
Beam
Convergent Current incident light intensity Unify incident light intensity into any value
Reflective
Type
Retroreflective
Type Stable detection over long and short periods Saves maintenance time
Chemical / Oil-
resistant Stabilized emission amount Threshold tracking function
Heat-
resistant The “four-chemical emitting element”, which we are the This function performs automatic setting to threshold
Vacuum- first to incorporate to maintain a stable level of light emis- value by checking the incident light intensity at desired
resistant
sion, has now become an industry standard. FX-500 intervals in order to follow the changes in the light
Liquid Leak /
Liquid Detection series continues to adopt the same emitting element as amount resulting from changes in the environment over
well as the “APC (Auto Power Control) circuit” which im- long periods (such as dust). This contributes to reduction
proves stability in short periods such as when the power in maintenance hours.
is turned on.
Fiber
Options
Suitable for preventative maintenance FX-502(P) ■ ‌Detect deterioration in light intensity
(e.g. Useful in dusty environment)
Self-diagnosis output FX-505(P)-C2
Semi-custom
fibers
FX-502(P) / 505(P)-C2 can set Output 2 as a self-
diagnosis output. When the teaching of Output
1’s threshold value is carried out, Output 2 is set
Fiber concurrently with the setting randomly shifted by the
Dimensions
amount of surplus of threshold value. Light intensity
Thru-beam
Type deterioration due to fiber breakage or dust accumulation
Self-diagnosis can be used with the threshold
Retroreflective can be notified as an alarm output.
Type tracking function for added effectiveness.
Reflective
Type Stable detection while being eco-friendly
Others Emission power & gain setting
In cases when the incident Detecting a transparent sheet
light intensity is saturated,
Amplifiers the light emitting amount Normal AUTO

FX-500 can be adjusted to the opti-


series mal level by AUTO without Object present
FX-100 changing the response time.
series
This allows stable detection
with an optimal S/N ratio
and saves energy by con- Object absent

INDEX trolling the emitting electric Saturated


current.
Auto mode (AUTO) and 3-level manual mode (H / M / L [fine-adjustable]) are incorporated.
73

Built-in logic functions New product


No PLC necessary, saving material and programming costs introduction
Tough
Fiber
Logical calculation functions Equipped with 5 timer types
3 logical calculations (AND, OR, Calculation of two neighboring amplifiers A wide variety of timer control
XOR) are available with fiber operations can be carried out by Fiber
sensor only. 3 logical operations Lower side Output 1 Calculation result fiber sensors only. Selection
Guide
output
can be selected against Output 1. Upper side Output 1 Normal operation Model
Time chart Set to L-ON
Additional controller is not Communication direction (Up to 12 units) Beam-
received Choose
required so both wire-saving and Sensing Beam- by shape/
interrupted application
cost reduction can be achieved. Calculation of two outputs in one amplifier FX-502(P) / 505(P)-C2 condition
ON
T1 How to read
ON-delay OFF Model No.
Detection fiber T1 T1
ON Earlier models
Output 1 Calculation result output OFF-delay OFF comparison
table
Output 2 Normal output operation ON
T1 T1
One-shot OFF

T1
ON
Calculation of one amplifier and external input FX-502(P) / 505(P)-C2 ON/OFF T2
OFF
-delay Fibers
ON-delay/ T1 T2
ON
One-shot OFF Super
External input
(sensor, contact, PLC, etc.) Quality
Synchronization fiber
Output 1 Calculation result output Timer period: 0.05 ms to 32 s Threaded
Output 1 has ON / OFF-delay and ON-delay / One-shot timers are available. Type
Square Head
Type
Cylindrical
Analog output cable type FX-505(P)-C2 Smooth setup changes by 8 data banks Type

Sleeve
To monitor the sensing of objects, a 4 to 20 mA analog The number of data banks used for saving the setup
current is output in respond to the digital value of the conditions of the amplifirer is increased to eight. Setup Flat
Type
incident light intensity. conditions can be saved and loaded to make setup
changes easy at a worksite where multiple models are Small
Spot
20
Edge tracking of film or sheet manufactured. Narrow
Beam
Wide
Actual position
Remote control improves work FX-502(P)
Output current (mA)

Drift position Beam

efficiency by external input FX-505(P)-C2 Convergent


Reflective
Type
Retroreflective
Work efficiency can be improved by operating via PLC Type
4
output or other external signal. Chemical / Oil-
0 Incident light intensity (digit) 4,000/8,000 (FX-502(P) can operate via external signal when resistant
switching from Output 2 to external input.) Heat-
resistant
Vacuum-
Functions operable by external input resistant
The drifting path can be monitored as
Full-auto / Limit / 2-point teaching Display adjustment setting Liquid Leak /
the light intensity changes. Liquid Detection
Data bank load / save Logical calculation (self-unit only)
Emission halt Copying function lock (self-unit only)
Fiber
Options

An optical communication function allows No need to specify a main unit or sub unit
sensors to be adjusted simultaneously All FX-500 amplifiers can be used as either a main unit Semi-custom
fibers
The data that is currently set can be copied and saved or a sub unit. Just use a main cable or a sub cable to
all at once for all amplifiers connected together from the distinguish the two. This reduces the costs of inventory
right side thanks to the optical communication function. management.
Fiber
This greatly reduces troublesome setup tasks and Dimensions
makes setup much smoother. Thru-beam
Type
Retroreflective
The same part number Type
can be used as either Reflective
a main unit or sub unit! Type
Single copy & save operation
for all amplifiers Others

Sub cable
Optical communication
window
Amplifiers
Main cable (3-core) FX-500
FX-501□
CN-73-C□ series
Sub cable (1-core)
CN-71-C□ FX-100
Main cable (4-core) series
CN-74-C□
FX-502□ Main cable Disconnection is possible without
Sub cable (2-core)
CN-72-C□ moving the amplifier sideways

INDEX
74

New product ORDER GUIDE


introduction
Tough
Fiber Amplifiers Quick-connection cable is not supplied with FX-501(P) and FX-502(P). Please order it separately.

Emitting
Type Appearance Model No. Output External input
Fiber element
Selection
Guide
FX-501 NPN open-collector transistor
Standard

Model
type


Choose
by shape/
application FX-501P PNP open-collector transistor
How to read
Model No
2-output type

Earlier models
FX-502 NPN open-collector transistor 2 outputs
comparison Incorporated
table Red LED
(Switchable with Output 2)
FX-502P PNP open-collector transistor 2 outputs

NPN open-collector transistor 2 outputs,


Cable type

Fibers FX-505-C2 analog output


Incorporated
Super PNP open-collector transistor 2 outputs,
Quality FX-505P-C2 analog output
Threaded
Type
Square Head Quick-connection cables
Type
Cylindrical For FX-501(P) Quick-connection cable is not supplied with the amplifier. Please order it separately.
Type
Main cable
Sleeve
Type Model No. Description
• CN-73-C□
Flat
Type
CN-73-C1 Length: 1 m 3.281 ft
Small 0.2 mm2 3-core cabtyre cable, with connector
Spot Main cable
(3-core)
CN-73-C2 Length: 2 m 6.562 ft on one end
Narrow Cable outer diameter: ø3.3 mm ø0.130 in
Beam CN-73-C5 Length: 5 m 16.404 ft Sub cable
Wide
Beam CN-71-C1 Length: 1 m 3.281 ft 0.2 mm 1-core cabtyre cable, with connector
2
• CN-71-C□
Convergent Sub cable on one end
Reflective (1-core)
CN-71-C2 Length: 2 m 6.562 ft
Cable outer diameter: ø3.3 mm ø0.130 in
Type
Retroreflective CN-71-C5 Length: 5 m 16.404 ft Connectable to a main cable up to 15 cables.
Type
Chemical / Oil-
resistant For FX-502(P) Quick-connection cable is not supplied with the amplifier. Please order it separately.
Heat-
resistant Main cable
Vacuum- Type Model No. Description
• CN-74-C□
resistant
Liquid Leak / CN-74-C1 Length: 1 m 3.281 ft
Liquid Detection 0.2 mm2 4-core cabtyre cable, with connector
Main cable
(4-core)
CN-74-C2 Length: 2 m 6.562 ft on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-74-C5 Length: 5 m 16.404 ft Sub cable
Fiber
Options CN-72-C1 Length: 1 m 3.281 ft 0.2 mm2 2-core cabtyre cable, with connector • CN-72-C□
Sub cable on one end
(2-core)
CN-72-C2 Length: 2 m 6.562 ft
Cable outer diameter: ø3.3 mm ø0.130 in
CN-72-C5 Length: 5 m 16.404 ft Connectable to a main cable up to 15 cables.
Semi-custom
fibers
End plates End plates are not supplied with the amplifier. Please order them separately when the amplifiers are mounted in cascade.

Fiber
Dimensions Appearance Model No. Description
Thru-beam
Type
When amplifiers are mounted in cascade, or when
Retroreflective an amplifier moves depending on the way it is
Type installed on a DIN rail, these end plates clamp
Reflective MS-DIN-E amplifiers into place on both sides. Make sure to
Type use end plates when cascading multiple amplifiers
together.
Others
Two pcs. per set

Amplifiers
FX-500
series
FX-100
series

INDEX
75

OPTIONS New product


introduction
Tough
Amplifier mounting bracket Fiber
Designation Model No. Description
• MS-DIN-2

Amplifier Fiber
MS-DIN-2 Mounting bracket for amplifier Selection
mounting bracket Guide

Model
Choose
Accessory Communication by shape/
application
window seal
• FX-MB1 (Amplifier protection seal) How to read
Model No.
10 sets of 2 communication window Earlier models
seals and 1 connector seal comparison
table
Connector seal

Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type

Sleeve

Flat
Type
Small
Spot
Narrow
Beam
Wide
Beam
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
76

New product SPECIFICATIONS


introduction
Tough
Fiber
Type Standard type 2-output type Cable type (Analog output type)
Model No.

NPN output FX-501 FX-502 FX-505-C2


Fiber Item PNP output FX-501P FX-502P FX-505P-C2
Selection
Guide +10
Supply voltage 12 to 24 V DC-15 % Ripple P-P 10 % or less
Model
Normal operation: 960 mW or less (current consumption 40 mA or less at 24 V supply voltage, excluding analog output of cable type)
Choose Power consumption
by shape/ ECO mode: 680 mW or less (current consumption 28 mA or less at 24 V supply voltage, excluding analog output of cable type)
application
How to read <NPN output type> <PNP output type>
Model No NPN open-collector transistor PNP open-collector transistor
Output • Maximum sink current: 100 mA
Earlier models • Maximum source current: 100 mA
comparison (2-output type and cable type: (2-output type and cable type are 50 mA) (Note 2)
table (2-output type and cable type are 50 mA) (Note 2)
Output 1, Output 2) • Applied voltage: 30 V DC or less (between output and 0 V) • Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (Note 3) (at maximum sink current) • Residual voltage: 2 V or less (Note 3) (at maximum source current)

Output points 1 point 2 points


Fibers
Output operation Switchable either Light-ON or Dark-ON by L/D mode
Super
Quality Short-circuit protection Incorporated
Threaded
Type Response time H-SP: 25 μs or less, FAST: 60 μs or less, STD: 250 μs or less, LONG: 2 ms or less, U-LG: 4 ms or less, HYPR: 24 ms or less, selectable
Square Head Output current: 4 to 20 mA approx. [H-SP, FAST, STD: At 0 to 4,000 digits, LONG: At 0 to 8,000 digits (Note 4)], Response time: 2 ms or
Type Analog output (Cable type only)
less, Zero point: Within 4 mA ±1 % F.S., Span: Within 16 mA ±5 % F.S., Linearity: Within ±3 % F.S., Load resistance: 0 to 250 Ω
Cylindrical
Type <NPN output type> <PNP output type>
NPN non-contact input PNP non-contact input
Sleeve External input • Signal condition • Signal condition
(2-output type only, switchable – High: +8 V to +V DC or Open High: +4 V to +V DC
Flat
Type with Output 2) Low: 0 to +1.2 V DC (at 3 mA sink current)
(at 0.5 mA source current) Low: 0 to +0.6 V DC or Open
Small • Input impedance: 10 kΩ approx. • Input impedance: 10 kΩ approx.
Spot
Narrow Emission halt / Teaching (Full-auto, Limit, 2-point) / Logic operation setting / Copy
Beam Possible external input function –
lock / Display adjustment / Data bank load / Data bank save, selectable
Wide
Beam Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching / Manual adjustment
Convergent
Reflective Incident light intensity display range H-SP / FAST / STD: 0 to 4,000, LONG: 0 to 8,000, U-LG / HYPR: 0 to 9,999
Type
Retroreflective <Output 1>
Type Incorporated with variable OFF-delay / ON-delay /One-shot / ON OFF-delay /
Incorporated with variable OFF-delay /
Chemical / Oil- ON-delay /One-shot / ON OFF-delay / ON-delay • One-shot timer, switchable either effective or ineffective
resistant Timer function
ON-delay • One-shot timer, switchable <Output 2>
Heat- either effective or ineffective Incorporated with variable OFF-delay / ON-delay /One-shot timer, switchable either
resistant
effective or ineffective
Vacuum-
resistant Timer range “ms”: 0.5 ms approx., 1 to 9,999 ms approx., 1 ms approx.,
Liquid Leak / Timer period Timer range “sec.”: 0.5 s approx., 1 to 32 s approx., 1 s approx.,
Liquid Detection Timer range “1/10 ms”: 0.05 ms approx., 0.1 to 999.9 ms approx., 0.1 ms approx., each output is set individually
Light emitting amount selection function Incorporated, 3 levels (each level 25 to 100 %) + Auto setting [1 level (25 to 100 %) when using H-SP mode]

Interference prevention function Incorporated (Note 5), selectable either automatic interference prevention or different frequency
Fiber
Options Hysteresis setting / Shift amount setting / Emission power setting / Display turning setting / ECO setting / Data bank loading
Various settings
saving setting / Copying setting / Code setting / Reset setting / Logical calculation setting / Threshold tracking setting, etc.

Protection IP40 (IEC)


Semi-custom
fibers -10 to +55 °C +14 to +131 °F [If 4 to 7 units are mounted in cascade: -10 to +50 °C +14 to +122 °F or if 8 to 16 units (cable type: 8 to 12 units)
Ambient temperature
are mounted in cascade: -10 to +45 °C +14 to +113 °F] (No dew condensation or icing allowed), Storage: -20 to +70 °C -4 to +158 °F

Emitting element (modulated) Red LED (Peak emission wavelength: 643 nm 0.025 mil)
Fiber Material Enclosure, Case cover: Polycarbonate, Switch: TPEE
Dimensions
Thru-beam Cable – 0.2 mm2 6-core cabtyre cable, 2 m 6.562 ft long
Type
Extension up to total 100 m 328.084 ft is
Retroreflective Cable extension – possible with 0.3 mm2, or more, cable.
Type
(however, supply voltage 12 V DC)
Reflective
Type Weight Net weight: 15 g approx., Gross weight: 70 g approx. Net weight: 60 g approx., Gross weight: 100 g approx.
Others Accessory FX-MB1 (Amplifier protection seal): 1 set
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) 50 mA max. if 5 or more standard types are connected together. (25 mA in case of 2-output type and cable type)
3) In case of using the quick-connection cable (cable length 5 m 16.404 ft) (optional).
Amplifiers 4) If display adjustment was conducted, it is not in this range.
5) Number of sensor heads which is possible to be mounted closely in auto interference prevention function depends on response time as shown in table below.
FX-500 Number of sensor heads which is possible to be mounted closely in different frequency Interference prevention function is up to 3 units.
series
● Number of sensor heads mountable closely (Unit: set)
FX-100
series Response time H-SP FAST STD LONG U-LG HYPR
IP-1 0 2 4 8 8 12

INDEX
77

I/O CIRCUIT AND WIRING DIAGRAMS New product


introduction
Tough
FX-501 NPN output type Fiber

I/O circuit diagram Terminal No. Wiring diagram Color code of quick-connection cable
Color code of quick-connection cable
Brown (Note 1) Fiber
(Brown) +V (Note 1) Selection
1 Guide
Load
Model
Sensor circuit

Load Black + 12 to 24 V DC
(Black) Output + 12 to 24 V DC –  
+10
%
2 -15 Choose
–  
+10
% by shape/
-15
100 mA max. (Note 2) Blue (Note 1) application

(Blue) 0 V (Note 1) Note: The quick-connection sub cable does not have a brown and a blue How to read
3 Model No.
lead wire.
Earlier models
comparison
Internal circuit User’s circuit table
Terminal arrangement diagram
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V
(blue). The power is supplied from the connector of the main cable. 1 +V
2) 50 mA max., if five amplifiers or more, are connected together.
2 Output Fibers
Super
0V
Quality
3

Threaded
FX-501P PNP output type Type
Square Head
I/O circuit diagram Terminal No. Wiring diagram Color code of quick-connection cable
Type
Color code of quick-connection cable
Cylindrical
Brown (Note 1)
(Brown) +V (Note 1) Type
1

Sleeve
Sensor circuit

Black + 12 to 24 V DC
100 mA max. (Note 2) + 12 to 24 V DC  
+10
2 – -15
% Flat

+10
(Black) Output – -15
% Load Type
Load Blue (Note 1)
Small
3
(Blue) 0 V (Note 1) Note: The quick-connection sub cable does not have a brown and a blue Spot
lead wire. Narrow
Internal circuit User’s circuit Beam
Terminal arrangement diagram Wide
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V Beam
(blue). The power is supplied from the connector of the main cable. 1 +V Convergent
2) 50 mA max., if five amplifiers or more, are connected together. Reflective
2 Output Type
Retroreflective
Type
3 0V
Chemical / Oil-
resistant
FX-502 NPN output type Heat-
resistant
I/O circuit diagram Terminal No. Wiring diagram Color code of quick-connection cable
Vacuum-
Color code of quick-connection cable resistant
Brown (Note 1)
(Brown) +V (Note 1) Liquid Leak /
1 Load Load Liquid Detection
White
Sensor circuit

Load Load +
(White) Output 2 / External input 12 to 24 V DC
4  
+10
+ 12 to 24 V DC Black – -15
%
50 mA max. (Note 2)  
+10
(Black) Output 1 – -15
% External
2
External Blue (Note 1) input Fiber
50 mA max. (Note 2) input
Note: The quick-connection sub cable does not have a brown and a blue Options
3
(Blue) 0 V (Note 1) lead wire.
Internal circuit User’s circuit
Terminal arrangement diagram Semi-custom
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V fibers
(blue). The power is supplied from the connector of the main cable. 1 +V
2) 25 mA max., if five amplifiers or more, are connected together. 2 Output 1 4 Output 2 / External input

Fiber
3 0V Dimensions
Thru-beam
FX-502P PNP output type Type
Terminal No. Color code of quick-connection cable Retroreflective
I/O circuit diagram Wiring diagram Type
Color code of quick-connection cable
Brown (Note 1) Reflective
(Brown) +V (Note 1) Type
1 External
50 mA max. (Note 2) External Black input
input + Others
Sensor circuit

2 12 to 24 V DC
(Black) Output 1 + 12 to 24 V DC White –  
+10
%
50 mA max. (Note 2) -15
–  
+10
% Blue Load Load
4 -15
(White) Output 2 / External input (Note 1)
Load Load
Note: The quick-connection sub cable does not have a brown and a blue Amplifiers
3
(Blue) 0 V (Note 1) lead wire.
FX-500
Internal circuit User’s circuit series
Terminal arrangement diagram
Notes: 1) The quick-connection sub cable does not have +V (brown) and 0 V FX-100
(blue). The power is supplied from the connector of the main cable. 1 +V series
2) 25 mA max., if five amplifiers or more, are connected together.
2 Output 1 4 Output 2 / External input

3 0V INDEX
78

New product I/O CIRCUIT AND WIRING DIAGRAMS


introduction
Tough
Fiber FX-505-C2 NPN output type

I/O circuit diagram Wiring diagram


Color code
Fiber (Brown) +V
Selection
Guide Brown
Load
(Pink) External input
Model Load
Sensor circuit

(Black) Output 1 Load Black


Choose + 12 to 24 V DC Load
by shape/ –
10
%
application 15 White
(White) Output 2 + 12 to 24 V DC
How to read Pink 10
Model No – 15
%
(Blue) 0 V
Earlier models Blue
comparison Load (0 to 250 Ω)
table (Gray) Analog output (4 to 20 mA)
Load (0 to 250 Ω)
Gray
Internal circuit User’s circuit

Fibers
Super
Quality
Threaded
Type FX-505P-C2 PNP output type
Square Head
Type I/O circuit diagram Wiring diagram
Color code
Cylindrical (Brown) +V
Type
Brown
Sleeve (Black) Output 1
Sensor circuit

Pink
Flat (White) Output 2 + 12 to 24 V DC
Type Load –
10
%
(Pink) External input
15 Black
Small + 12 to 24 V DC
Spot Load White –
10
%
(Blue) 0 V Load 15
Narrow Load
Beam (Gray) Analog output (4 to 20 mA) Load (0 to 250 Ω) Blue
Wide Load (0 to 250 Ω)
Beam Gray
Internal circuit User’s circuit
Convergent
Reflective
Type
Retroreflective
Type
Chemical / Oil-
resistant
Heat-
resistant
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
79

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Tough
Thru-beam type Parallel deviation  Sensing characteristics are listed in the alphabetic order of the Model No. Fiber

FT-140 Thru-beam type FT-30 Thru-beam type FT-31 Thru-beam type FT-31S Thru-beam type
Fiber
20,000 1,500 1,500 1,500 Selection
Guide
787.400 HYPR 59.055 HYPR 59.055 HYPR 59.055 HYPR
Model
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


15,000 STD Choose
590.550 1,000 1,000 1,000 by shape/
39.370 39.370 39.370 application
How to read
10,000
393.700 H-SP
Model No.
Fiber STD Fiber Fiber Fiber Earlier models
head 500 head 500 head 500 head comparison
ℓ 19.685 ℓ 19.685 STD ℓ 19.685
STD ℓ table
5,000
196.850 L L L H-SP L
Fiber H-SP H-SP Fiber
Fiber Fiber head
head head head
0 0 0 0
1,500 1,000 500 0 500 1,000 1,500 600 400 200 0 200 400 600 800 600 400 200 0 200 400 600 800 600 400 200 0 200 400 600 Fibers
59.055 39.370 19.685 19.685 39.370 59.055 23.622 15.748 7.874 7.874 15.748 23.622 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 23.622 15.748 7.874 7.874 15.748 23.622
Left Center Right Left Center Right Left Center Right Left Center Right Super
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Quality
Threaded
Type
FT-31W Thru-beam type FT-40 Thru-beam type FT-42 Thru-beam type FT-42S Thru-beam type
FTA225 Square Head
FTA219 FTA186 Type
1,200 FTA187 4,000 3,500 3,000 Cylindrical
47.244 157.480 137.795 118.110
HYPR HYPR HYPR HYPR Type
1,000 3,000 2,500
Setting distance L (mm in)

Sleeve
118.110
Setting distance L (mm in)

39.370 98.425
Setting distance L (mm in)

Setting distance L (mm in)


3,000
118.110 2,500
800 2,000
31.496
98.425
78.740 Flat
2,000 Type
600 2,000 78.740 STD 1,500
23.622 78.740 1,500 59.055 STD Small
STD Fiber
head
STD Fiber
59.055
Fiber Fiber Spot
400 head head 1,000 head
15.748 ℓ
1,000 ℓ 1,000 ℓ 39.370 H-SP ℓ Narrow
L 39.370 L
39.370 L L Beam
200 500
H-SP 500 Wide
Fiber H-SP H-SP Fiber
7.874 Fiber 19.685 Fiber 19.685 head
head head head Beam
0 0 0
2,000 Convergent
0
300 200 100 0 100 200 300 2,000 1,000 0 1,000 2,000 2,000 1,000 0 1,000 2,000 2,000 1,000 0 1,000
11.811 7.874 3.937 3.937 7.874 11.811 78.740 39.370 39.370 78.740 78.740 39.370 39.370 78.740 78.740 39.370 39.370 78.740 Reflective
Type
Left Center Right Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Retroreflective
Type
Chemical / Oil-
resistant
FT-42W Thru-beam type FT-43 Thru-beam type FT-45X Thru-beam type
FTA221 Heat-
FTA180 FTA224 resistant
4,000 2,500 1,500 FTA185
157.480 98.425 59.055 HYPR Vacuum-
resistant
HYPR HYPR
2,000 Liquid Leak /
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

3,000 78.740 STD


118.110 Liquid Detection
STD 1,000
1,500 39.370
59.055
2,000
78.740 Fiber Fiber Fiber
STD 1,000
head
39.370 head head Fiber
ℓ 500
H-SP ℓ 19.685
H-SP ℓ Options
1,000 L
39.370 500 L L
H-SP Fiber 19.685 Fiber Fiber
head head head
0 0
1,500 1,000 500 0 500 1,000 1,500 2,000 1,000 0 1,000 2,000
0
1,500 1,000 500 0 500 1,000 1,500 Semi-custom
59.055 39.370 19.685 19.685 39.370 59.055 78.740 39.370 39.370 78.740 59.055 39.370 19.685 19.685 39.370 59.055 fibers
Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

Fiber
FT-A11 Thru-beam type FT-A11W Thru-beam type Dimensions
FTA183 FTA192 Thru-beam
Horizontal direction
FTA179 Vertical direction Horizontal direction Vertical direction Type

4,000 4,000 4,000 4,000 Retroreflective


157.480 157.480 157.480 157.480 Type
HYPR HYPR HYPR HYPR
Reflective
Type
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)
Setting distance L (mm in)

3,000 STD 3,000 STD 3,000 STD 3,000 STD


118.110 118.110 118.110 118.110
Others
H-SP H-SP
2,000 2,000 2,000 2,000
78.740 Fiber 78.740 Fiber 78.740 Fiber 78.740 Fiber
H-SP head H-SP head head head

ℓ 8mm ℓ ℓ 8mm ℓ
1,000 1,000 0.315in L 1,000 1,000 0.315in L Amplifiers
39.370 L 39.370 39.370 L 39.370
Fiber Fiber Fiber Fiber FX-500
head head head head series
0 0 0 0
400 300 200 100 0 100 200 300 400 400 300 200 100 0 100 200 300 400 600 400 200 0 200 400 600 600 400 200 0 200 400 600 FX-100
15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 23.622 15.748 7.874 7.874 15.748 23.622 23.622 15.748 7.874 7.874 15.748 23.622 series
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

INDEX
FTA162 FTA162 FTA217 FTA217
80

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No.
(Models with same sensing characteristics are grouped together.)
FT-A32 Thru-beam type FT-A32W Thru-beam type
Fiber
Selection
Guide
Horizontal direction Vertical direction Horizontal direction Vertical direction
4,000 4,000 4,000 4,000
Model 157.480 157.480 157.480 157.480
HYPR HYPR HYPR HYPR
Choose STD STD
by shape/
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


application
Setting distance L (mm in)

3,000 STD 3,000 STD 3,000 3,000


118.110 118.110 118.110 118.110
How to read H-SP H-SP
Model No H-SP H-SP Fiber
head
Earlier models 2,000 2,000 2,000 2,000
comparison 78.740 Fiber 78.740 Fiber 78.740 ℓ 78.740 Fiber
table head head head
L
ℓ 19mm ℓ 19mm ℓ
1,000 1,000 0.748in L 1,000 1,000 0.748in L
39.370 L 39.370 39.370 39.370
Fiber
Fiber Fiber head Fiber
Fibers head
0
head
0 0
head
0
300 200 100 0 100 200 300 300 200 100 0 100 200 300 300 200 100 0 100 200 300 300 200 100 0 100 200 300
Super 11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811
Quality Left Center Right Down Center Up Left Center Right Down Center Up
Threaded Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Type
Square Head
Type FT-AL05 Thru-beam type
FTA216
FT-E13 Thru-beam type FT-E23 Thru-beam type
FTA218
Cylindrical FTA216 FTA218
Type Horizontal direction Vertical direction
Sleeve 2,500 2,500 60 300
98.425 HYPR 98.425 HYPR 2.362 HYPR 11.811 HYPR
Flat 50 250
Type 2,000 2,000
Setting distance L (mm in)

Setting distance L (mm in)


1.969 9.843
Setting distance L (mm in)

Setting distance L (mm in)

78.740 78.740
Small 40 200
Spot 1,500 1,500 1.575 7.874
59.055 59.055
Narrow STD STD 30 STD 150 STD
Beam Fiber 1.181
Fiber
5.906
Fiber
1,000 Fiber 1,000 head
Wide 39.370 head 39.370 20 head 100 head
Beam ℓ 0.787 ℓ 3.937 ℓ
H-SP H-SP 36mm ℓ
Convergent 500 L 500 1.417in L
10
L
50
L
Reflective 19.685 Fiber 19.685
0.394 H-SP Fiber 1.969
H-SP Fiber
Type head Fiber head head
head
Retroreflective 0 0 0 0
Type 1,500 1,000 500 0 500 1,000 1,500 1,500 1,000 500 0 500 1,000 1,500 30 20 10 0 10 20 30 150 100 50 0 50 100 150
59.055 39.370 19.685 19.685 39.370 59.055 59.055 39.370 19.685 19.685 39.370 59.055 1.181 0.787 0.394 0.394 0.787 1.181 5.906 3.937 1.969 1.969 3.937 5.906
Chemical / Oil- Left Center Right Down Center Up Left Center Right Left Center Right
resistant Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Heat-
resistant
Vacuum- FT-H13-FM2 Thru-beam type FT-H20-J20-S  FT-H20-J30-S Thru-beam FT-H20-M1 Thru-beam type
resistant FTA215 FT-H20-J50-S FTA215 type FTA222 FTA223
Liquid Leak / 4,000 2,000 2,000
Liquid Detection 157.480 Fiber 78.740 Fiber
head
78.740
head HYPR
ℓ ℓ
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

3,000 L 1,500 L 1,500


118.110 Fiber 59.055 Fiber 59.055
head head
Fiber HYPR STD
Options 2,000 HYPR 1,000 1,000
78.940 39.370 STD 39.370
Fiber
STD head
1,000 500 H-SP 500 ℓ
Semi-custom 39.370 H-SP 19.685 19.685 H-SP L
fibers Fiber
head
0 0 0
1,000 500 0 500 1,000 800 400 0 400 800 2,000 1,000 0 1,000 2,000
39.370 19.685 19.685 39.370 31.496 15.748 15.748 31.496 78.740 39.370 39.370 78.740
Left Center Right Left Center Right Left Center Right
Fiber Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Dimensions
Thru-beam
Type
FT-H20-VJ50-S  FT-H20-VJ80-S Thru-beam type FT-H20W-M1 Thru-beam type FT-H30-M1V-S Thru-beam type
Retroreflective
Type
Reflective
Horizontal direction Vertical direction Horizontal direction Vertical direction
Type 2,000
Fiber head 78.740
Others HYPR
ℓ L
2,000 2,000 1,000
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

78.740 HYPR 78.740 Fiber head 1,500 39.370


59.055
HYPR
HYPR
STD
STD
Amplifiers Fiber STD
1,000
39.370
1,000 STD Fiber
1,000 head 500
FX-500 39.370

39.370 Fiber 19.685 head
series H-SP head ℓ
500 H-SP
L H-SP
19.685 ℓ L
FX-100 H-SP L
series Fiber Fiber Fiber
head head head
0 0 0 0
400 200 0 200 400 400 200 0 200 400 800 400 0 400 800 800 400 0 400 800
15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748 31.496 15.748 15.748 31.496 31.496 15.748 15.748 31.496
Left Center Right Down Center Up Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
INDEX
81

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Thru-beam type Parallel deviation Sensing characteristics are listed in the alphabetic order of the Model No. Tough
Fiber
(Models with same sensing characteristics are grouped together.)
FT-H35-M2 FT-HL80Y Thru-beam type FT-KS40 Thru-beam type
Thru-beam type
FT-H35-M2S6 Fiber
2,000 4,000 4,000 Selection
Guide
78.740 157.480 157.480 HYPR
HYPR Model
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)
1,500 3,000 3,000 STD Choose
59.055 HYPR 118.110 118.110 by shape/
STD application
How to read
1,000 2,000 2,000 Fiber Model No.
39.370 STD 78.740 78.740 head
H-SP H-SP Earlier models
Fiber Fiber comparison
head head
ℓ table
500 1,000 1,000
19.685 H-SP ℓ 39.370 ℓ 39.370 L
L L Fiber
Fiber Fiber
head head head
0 0 0
1,000 500 0 500 1,000 800 400 0 400 800 100 50 0 50 100 Fibers
39.370 19.685 19.685 39.370 31.496 15.748 15.748 31.496 3.937 1.969 1.969 3.937
Left Center Right Left Center Right
Super
Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Quality
Threaded
Type
FT-KV26 Thru-beam type FT-KV40 FTA208 Thru-beam type
Square Head
Type
Horizontal direction Vertical direction Horizontal direction Vertical direction Cylindrical
3,000 3,000 4,000 4,000 Type
118.110 118.110 157.480 157.480
HYPR HYPR HYPR HYPR Sleeve
2,500 2,500
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

98.425 98.425
Flat

Setting distance L (mm in)


3,000 STD 3,000 STD
2,000 2,000 118.110 118.110 Type
78.740 78.740
Small
1,500 STD 1,500 STD 2,000 H-SP 2,000 H-SP Spot
59.055 59.055 78.740 78.740
Fiber Fiber
Fiber Fiber Narrow
1,000 ℓ
head 1,000 head

head head Beam
39.370 39.370
H-SP H-SP
ℓ L
1,000 1,000
ℓ L Wide
Beam
500 L 500 39.370 L 39.370
19.685 Fiber 19.685 Fiber Fiber Fiber
head head head Convergent
0
head
0 Reflective
0
80 60 40 20 0 20 40 60 80
0
80 60 40 20 0 20 40 60 80 100 50 0 50 100 100 50 0 50 100 Type
3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 3.937 1.969 1.969 3.937 3.937 1.969 1.969 3.937 Retroreflective
Left Center Right Down Center Up Left Center Right Down Center Up Type
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Chemical / Oil-
resistant
Heat-
FT-KV40W FTA209 Thru-beam type
FTA209 FT-L80Y Thru-beam type
FTA205 FT-R40 Thru-beam type
FTA205 resistant
Vacuum-
Horizontal direction Vertical direction resistant
4,000 4,000 4,000 4,000 Liquid Leak /
157.480
HYPR
157.480
HYPR
157.480 157.480 HYPR Liquid Detection
HYPR
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

3,000 STD 3,000 STD 3,000 3,000


118.110 118.110 118.110 STD 118.110
Fiber
2,000 2,000 2,000
H-SP
2,000 Options
H-SP H-SP
78.740 78.740 78.740 78.740
Fiber Fiber Fiber
head head Fiber head
ℓ STD ℓ
1,000 1,000 1,000 head 1,000
39.370 39.370 ℓ L 39.370 ℓ 39.370 L Semi-custom
L L
Fiber Fiber Fiber H-SP Fiber fibers
head head head head
0 0 0 0
100 50 0 50 100 100 50 0 50 100 800 400 0 400 800 1,500 1,000 500 0 500 1,000 1,500
3.937 1.969 1.969 3.937 3.937 1.969 1.969 3.937 31.496 15.748 15.748 31.496 59.055 39.370 19.685 19.685 39.370 59.055
Left Center Right Down Center Up Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Fiber
Operating point ℓ (mm in)
Dimensions
Thru-beam
Type
FT-R41W FTA206 Thru-beam type FT-R42W Thru-beam type
Retroreflective
FTA206 Type
Horizontal direction Vertical direction Horizontal direction Vertical direction
FTA184
Reflective
3,500 3,500 4,000 4,000 Type
137.795 HYPR 137.795 HYPR 157.480 HYPR 157.480 HYPR
3,000 3,000 Others
118.110 118.110
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

3,000 STD 3,000 STD


2,500 2,500 118.110 118.110
98.425 98.425
2,000 2,000
78.740 78.740 2,000
78.740
2,000
78.740 Amplifiers
1,500 Fiber 1,500 Fiber H-SP Fiber H-SP Fiber
59.055 head 59.055 head head
STD STD head FX-500
1,000 ℓ 1,000
ℓ 1,000 ℓ 1,000 ℓ series
39.370 H-SP L 39.370 H-SP 39.370 L 39.370 L
500 500
L FX-100
19.685
Fiber
19.685 Fiber Fiber Fiber series
head head head head
0 0
0 1,500 1,000 500 0 500 1,000 1,500 0 1,500 1,000 500 0 500 1,000 1,500 1,000 500 0 500 1,000 1,000 500 0 500 1,000
59.055 39.370 19.685 19.685 39.370 59.055 59.055 39.370 19.685 19.685 39.370 59.055 39.370 19.685 19.685 39.370 39.370 19.685 19.685 39.370
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
INDEX

FTA193 FTA194 FTA194


FTA193
82

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber Thru-beam type Parallel deviation  Sensing characteristics are listed in the alphabetic order of the Model No.
FT-R44Y Thru-beam type FT-R60Y Thru-beam type
Fiber
Selection
Guide
Horizontal direction Vertical direction Horizontal direction Vertical direction
3,000 3,000 4,000 4,000
Model 118.110 118.110 157.480 157.480
HYPR HYPR HYPR HYPR
Choose
by shape/
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


application 3,000 3,000
118.110 118.110
How to read 2,000
78.740
2,000
78.740
Model No
Earlier models 2,000 2,000
comparison 78.740 78.740
STD STD
Fiber Fiber STD Fiber STD Fiber
table head head head head
1,000 1,000
39.370 ℓ
39.370 ℓ 1,000 ℓ 1,000 ℓ
L L 39.370 L 39.370 L
H-SP Fiber H-SP Fiber H-SP Fiber H-SP Fiber
head head head head
Fibers 0 0 0 0
1,200 800 400 0 400 800 1,200 1,200 800 400 0 400 800 1,200 1,000 500 0 500 1,000 1,000 500 0 500 1,000
Super 47.244 31.496 15.748 15.748 31.496 47.244 47.244 31.496 15.748 15.748 31.496 47.244 39.370 19.685 19.685 39.370 39.370 19.685 19.685 39.370
Quality Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Threaded
Type
Square Head
Type FTA227 FTA227 FTA226 FTA226
FT-S11 Thru-beam type FT-S20 Thru-beam type FT-S21 Thru-beam type FT-S21W Thru-beam type
Cylindrical
Type
400 1,500 1,500 1,200
Sleeve 15.748 HYPR 59.055 HYPR 59.055 HYPR 47.244 HYPR
1,000
Flat

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

300 39.370
Type 11.811
1,000 1,000 800
Small 39.370 39.370 31.496
Spot 200 600
Fiber Fiber Fiber
Narrow 7.874
STD Fiber STD head head 23.622 head
Beam head
500 500 400
ℓ ℓ
STD ℓ STD ℓ
Wide 100 19.685 19.685 15.748
Beam 3.937
H-SP
L L L 200 H-SP
L
Fiber H-SP H-SP
Convergent head
Fiber Fiber 7.874 Fiber
Reflective 0 head 0
head head
Type 150 100 50 0 50 100 150
0 0
600 400 200 0 200 400 600 800 600 400 200 0 200 400 600 800 300 200 100 0 100 200 300
Retroreflective 5.906 3.937 1.969 1.969 3.937 5.906 23.622 15.748 7.874 7.874 15.748 23.622 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 11.811 7.874 3.937 3.937 7.874 11.811
Type Left Center Right
Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Chemical / Oil- Operating point ℓ (mm in)
resistant
Heat-
resistant FT-S30 Thru-beam type
FTA178 FT-S31W Thru-beam type
FTA227 FT-S32 Thru-beam type
FTA182
Vacuum-
resistant FTA220
4,000 4,000 4,000
Liquid Leak / 157.480 HYPR 157.480 HYPR 157.480 HYPR
Liquid Detection
STD
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)

3,000 3,000 3,000


118.110 118.110 118.110

Fiber 2,000 2,000 2,000


Options 78.740 Fiber
head
78.740 78.740
H-SP
STD Fiber Fiber
head head
ℓ STD ℓ ℓ
1,000 1,000 1,000
39.370 L 39.370 L 39.370 L
H-SP
Semi-custom H-SP Fiber Fiber Fiber
fibers 0
head
0
head
0
head

2,000 1,000 0 1,000 2,000 1,500 1,000 500 0 500 1,000 1,500 1,000 500 0 500 1,000
78.740 39.370 39.370 78.740 59.055 39.370 19.685 19.685 39.370 59.055 39.370 19.685 19.685 39.370
Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Fiber
Dimensions
Thru-beam
Type FT-V23 Thru-beam type FT-V24W Thru-beam type
FTA226 FTA177
Retroreflective FTA181
Type Horizontal direction Vertical direction Horizontal direction Vertical direction
Reflective 2,000 2,000 400 400
Type 78.740
HYPR
78.740
HYPR
15.748 15.748
HYPR HYPR
Others
Setting distance L (mm in)
Setting distance L (mm in)
Setting distance L (mm in)
Setting distance L (mm in)

1,500 1,500 300 300


59.055 59.055 11.811 11.811
STD
1,000 STD 1,000 STD 200 200
39.370 39.370 7.874 7.874 STD
Amplifiers Fiber Fiber Fiber Fiber
head
head head head
ℓ ℓ ℓ ℓ
FX-500 500 500 100 100
series 19.685 H-SP L 19.685 H-SP L 3.937 H-SP L 3.937 H-SP L
Fiber Fiber
FX-100 head
Fiber
head head
Fiber
head
series 0 0 0 0
800 600 400 200 0 200 400 600 800 800 600 400 200 0 200 400 600 800 200 100 0 100 200 200 100 0 100 200
31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 7.874 3.937 3.937 7.874 7.874 3.937 3.937 7.874
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

INDEX
FTA190 FTA188 FTA188
FTA190
83

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Tough
Thru-beam type Parallel deviation  Sensing characteristics are listed in the alphabetic order of the Model No. Fiber

FT-V25 Thru-beam type FT-V30 Thru-beam type


Fiber
Horizontal direction Vertical direction Horizontal direction Vertical direction Selection
Guide
1,000 1,000 2,500 2,500
39.370 39.370 98.425 98.425 Model
HYPR HYPR HYPR HYPR
Choose
800 800 2,000 2,000 by shape/

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


31.496 31.496 78.740 78.740 application
How to read
600
23.622
600
23.622
1,500 1,500 Model No.
STD STD 59.055 59.055
STD STD Earlier models
comparison
400 Fiber 400 Fiber 1,000 Fiber 1,000 Fiber table
15.748 head 15.748 ℓ
head 39.370 head 39.370 head
ℓ ℓ ℓ
200 H-SP L 200 H-SP L 500 H-SP 500 H-SP L
7.874 7.874 L
19.685 19.685
Fiber Fiber Fiber Fiber
0
head
0 head
0
head
0
head Fibers
300 200 100 0 100 200 300 300 200 100 0 100 200 300 1,000 500 0 500 1,000 1,000 500 0 500 1,000
11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811 39.370 19.685 19.685 39.370 39.370 19.685 19.685 39.370 Super
Left Center Right Down Center Up Left Center Right Down Center Up Quality
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Threaded
Type

FTA189 Square Head


FTA191 Type
FT-V40 FTA189 Thru-beam type FT-V80Y FTA191 Thru-beam type
Cylindrical
Type
Horizontal direction Vertical direction Horizontal direction Vertical direction
4,000 4,000 4,000 4,000 Sleeve
157.480 157.480 157.480 157.480
HYPR HYPR HYPR HYPR Flat
Type
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)


3,000 3,000 3,000 3,000
Small
STD STD
118.110 118.110 118.110 118.110
STD STD Spot

2,000 2,000 2,000 Narrow


78.740
H-SP 2,000
78.740
H-SP
78.740 78.740 Beam
Fiber
Wide
Fiber H-SP
head head
1,000

1,000
H-SP Fiber head
ℓ 1,000 Fiber head Beam
1,000
39.370 39.370 ℓ L 39.370 39.370 ℓ Convergent
L
L L Reflective
Fiber Fiber Type
head head Fiber head Fiber head
0 0 0 0 Retroreflective
300 200 100 0 100 200 300 300 200 100 0 100 200 300 800 400 0 400 800 800 400 0 400 800 Type
11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811 31.496 15.748 15.748 31.496 31.496 15.748 15.748 31.496
Left Center Right Down Center Up Left Center Right Down Center Up Chemical / Oil-
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) resistant
Heat-
resistant
FT-Z20HBWFTA207
Thru-beam type FT-Z20W Thru-beam type Vacuum-
FTA207 resistant

Horizontal direction Vertical direction Liquid Leak /


Liquid Detection
1,200 2,000 2,000
47.244 HYPR 78.740 HYPR 78.740 HYPR
1,000
Setting distance L (mm in)

39.370
Setting distance L (mm in)

Setting distance L (mm in)

1,500 1,500 Fiber


800 59.055 59.055 Options
31.496
600 Fiber 1,000 STD 1,000 STD
23.622 head 39.370 Fiber 39.370 Fiber
head head
400 STD ℓ Semi-custom
15.748 ℓ ℓ fibers
H-SP L 500 500 1.2mm L
19.685 L 19.685 0.047in
200
7.874 Fiber H-SP Fiber H-SP
Fiber
head head head
0 0 0
600 400 200 0 200 400 600
23.622 15.748 7.874 7.874 15.748 23.622
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748
400 300 200 100 0 100 200 300 400
15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 Fiber
Left Center Right Left Center Right Down Center Up Dimensions
Operating point ℓ (mm in) Operating point ℓ (mm in)
Operating point ℓ (mm in) Thru-beam
Type
Retroreflective
FTA294
FT-Z30 FTA203 Thru-beam type FT-Z30E FTA294 Thru-beam type Type
Reflective
Type
Horizontal direction Vertical direction Horizontal direction Vertical direction
4,000 4,000 4,000 4,000 Others
157.480 HYPR 157.480 HYPR 157.480 HYPR 157.480 HYPR
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

3,000 STD 3,000 STD 3,000 STD 3,000 STD


118.110 118.110 118.110 118.110
Amplifiers
2,000 2,000
2,000 2,000
78.740 Fiber 78.740 Fiber FX-500
78.740 Fiber 78.740 Fiber series
H-SP H-SP H-SP head H-SP ℓ head
head head
ℓ ℓ ℓ FX-100
1,000 1,000 1,000 1,000 L series
L L 39.370 L 39.370 5.5mm
39.370 2.2mm 39.370 5.5mm 0.217in
0.087in 0.217in Fiber Fiber
Fiber Fiber
head head head
head 0 0 0
0
1,000 500 0 500 1,000 1,000 500 0 500 1,000 300 200 100 0 100 200 300 300 200 100 0 100 200 300
11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811
39.370 19.685
Left Center
19.685
Right
39.370 39.370 19.685
Down Center
19.685
Up
39.370
Left Center Right Down Center Up INDEX
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FTA198
FTA198 FTA163 FTA163
84

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber Thru-beam type Parallel deviation  Sensing characteristics are listed in the alphabetic order of the Model No.
FT-Z30EW Thru-beam type FT-Z30H Thru-beam type
Fiber
Selection
Guide
Horizontal direction Vertical direction Horizontal direction Vertical direction
4,000 4,000 4,000 4,000
Model 157.480 157.480 157.480 157.480
HYPR HYPR HYPR HYPR
Choose
by shape/
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)
application 3,000 STD 3,000 STD 3,000 STD 3,000 STD
118.110 118.110 118.110 118.110
How to read
Model No
Earlier models 2,000 2,000 2,000 2,000 Fiber
comparison 78.740 Fiber 78.740 Fiber 78.740 Fiber 78.740 head
table H-SP head H-SP ℓ head H-SP head H-SP

ℓ ℓ
1,000 1,000 L 1,000 1,000 L
5.5mm 39.370 5.5mm
39.370 L 39.370 39.370 L 0.217in
0.217in
Fiber Fiber Fiber Fiber
head
Fibers 0 0
head
0
head
0
head

400 200 0 200 400 400 200 0 200 400 400 200 0 200 400 400 200 0 200 400
Super 15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748
Quality Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Threaded
Type
Square Head FTA200
Type FT-Z30HW FTA200 Thru-beam type FT-Z30W FTA201 Thru-beam type
FTA201
Cylindrical
Type Horizontal direction Vertical direction Horizontal direction Vertical direction
Sleeve 4,000 4,000 4,000 4,000
157.480 HYPR 157.480 HYPR 157.480 HYPR 157.480 HYPR
Flat
Type

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

3,000 STD 3,000 STD 3,000 STD 3,000 STD


Small 118.110 118.110 118.110 118.110
Spot
Narrow 2,000 2,000 Fiber 2,000 2,000
Beam 78.740 Fiber 78.740 head 78.740
H-SP Fiber 78.740
H-SP Fiber
H-SP head H-SP head
head
Wide ℓ ℓ ℓ

Beam 1,000 1,000 L 1,000 1,000
5.5mm L L
Convergent 39.370 L 39.370
0.217in
39.370 2.2mm 39.370 5.5mm
Reflective Fiber 0.087in Fiber 0.217in
Type head
Fiber
head
Fiber
head head
Retroreflective 0 0 0 0
Type 400 200 0 200 400 400 200 0 200 400 1,000 500 0 500 1,000 1,000 500 0 500 1,000
15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748 39.370 19.685 19.685 39.370 39.370 19.685 19.685 39.370
Chemical / Oil- Left Center Right Down Center Up Left Center Right Down Center Up
resistant Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Heat-
resistant
Vacuum- FT-Z40W Thru-beam type FT-Z40HBWFTA199
Thru-beam type FT-Z802Y FTA199
Thru-beam type
resistant
FTA202 FTA202
Liquid Leak / Horizontal direction Vertical direction
Liquid Detection
4,000 4,000 4,000 4,000
157.480 HYPR 157.480 HYPR 157.480 HYPR 157.480
HYPR
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

3,000 3,000 3,000 3,000


Fiber 118.110 118.110 118.110 118.110 STD
Options
2,000 STD 2,000 STD 2,000 Fiber 2,000 H-SP
78.740 Fiber 78.740 Fiber 78.740 head 78.740
head head Fiber
ℓ STD head
Semi-custom ℓ ℓ
fibers 1,000
L
1,000 1.2mm
0.047in

L
1,000
39.370
H-SP L 1,000
39.370 L
39.370 39.370
H-SP Fiber H-SP Fiber Fiber
Fiber head
head head head
0 0 0 0
800 600 400 200 0 200 400 600 800 800 600 400 200 0 200 400 600 800 1,500 1,000 500 0 500 1,000 1,500 800 400 0 400 800
Fiber 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 31.496 23.622 15.748 7.874 7.874 15.748 23.622 31.496 59.055 39.370 19.685 19.685 39.370 59.055 31.496 15.748 15.748 31.496
Dimensions Left Center Right Down Center Up Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Thru-beam
Type
Retroreflective
Type Retroreflective type Parallel deviation  Sensing characteristics are listed in the alphabetic order of the Model No.
Reflective FTA295 FTA295 FTA204
Type FR-KZ22E Retroreflective type FR-KZ50E Retroreflective type
Others
Horizontal direction Vertical direction Horizontal direction Vertical direction
600 600 1,200 1,200
23.622 HYPR 23.622 HYPR 47.244 47.244
HYPR HYPR
500 500 1,000 1,000
Amplifiers
Setting distance L (mm in)

19.685 19.685 39.370 39.370


Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)

400 400 800 800


FX-500 15.748
STD
15.748
STD
31.496 31.496
series
300 300 600 600
FX-100 11.811 11.811 Reflector 23.622 STD Reflector 23.622 STD
Reflector
series Reflector RF-003 RF-003
400 ℓ ℓ
200 H-SP 200 H-SP ℓ 400
7.874 ℓ 7.874 15.748 H-SP 15.748 H-SP 3mm
L 0.118in L
L L
100 100 200 200
3.937 Fiber 3.937 Fiber 7.874 7.874 Fiber
head Fiber
head head
INDEX 0 0
head
0
0
20 10 0 10 20 20 10 0 10 20 10 5 0 5 10 10 5 0 5 10
0.787 0.394 0.394 0.787 0.787 0.394 0.394 0.787 0.394 0.197 0.197 0.394 0.394 0.197 0.197 0.394
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FRA014
85

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Tough
Retroreflective type Parallel deviation  Sensing characteristics are listed in the alphabetic order of the Model No. Fiber

FR-KZ50H Retroreflective type


Fiber
Horizontal direction Vertical direction Selection
Guide
1,200 1,200
47.244 47.244 Model
HYPR HYPR
1,000 1,000 Choose
by shape/
Setting distance L (mm in)

39.370 39.370

Setting distance L (mm in)


application
800 800 How to read
31.496 31.496 Model No.
600 600 Earlier models
23.622 STD Reflector 23.622 STD Reflector comparison
RF-003
RF-003 table
400 ℓ 400 ℓ
15.748 H-SP 15.748 H-SP
L L
200 200
7.874 Fiber 7.874 Fiber
head head Fibers
0 0
20 10 0 10 20 20 10 0 10 20
0.787 0.394 0.394 0.787 0.787 0.394 0.394 0.787 Super
Left Center Right Down Center Up Quality
Operating point ℓ (mm in) Operating point ℓ (mm in)
Threaded
Type
FR-Z50HW Retroreflective type Square Head
FRA013 Type
With Reflective tape RF-13 (attached) FRA013 With reflector RF-230 (optional) Cylindrical
Type
Horizontal direction Vertical direction Horizontal direction Vertical direction
2,000 2,000 4,000 4,000 Sleeve
78.740 HYPR 78.740 HYPR 157.480 HYPR 157.480 HYPR
Flat
Type

Setting distance L (mm in)


Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)

1,500 1,500 3,000 3,000


59.055 STD 59.055 STD 118.110 STD 118.110 STD Small
Spot
Narrow
1,000
39.370
1,000
39.370
2,000
78.740
H-SP 2,000
78.740
H-SP Beam
H-SP H-SP Reflective tape Reflector
Wide
Reflective tape Reflector
RF-13 RF-13 RF-230 RF-230
ℓ ℓ ℓ ℓ Beam
500 500 1,000 1,000
19.685 19.685 L 39.370 39.370 L Convergent
L L Reflective
Fiber Fiber Fiber Fiber Type
head head head head
0 0 0 0 Retroreflective
150 100 50 0 50 100 150 150 100 50 0 50 100 150 400 300 200 100 0 100 200 300 400 400 300 200 100 0 100 200 300 400 Type
5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748 15.748 11.811 7.874 3.937 3.937 7.874 11.811 15.748
Down Center Up Chemical / Oil-
resistant
Left Center Right Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Heat-
resistant
Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No. Vacuum-
FRA010 FRA010 resistant
FRA011
FD-30 Reflective type FD-31 FRA011 Reflective type Liquid Leak /
Liquid Detection
Horizontal direction Vertical direction Horizontal direction Vertical direction
800 800 600 600
31.496 31.496 23.622 23.622
HYPR HYPR HYPR HYPR Fiber
500 500 Options
Setting distance L (mm in)

Setting distance L (mm in)

19.685 19.685
Setting distance L (mm in)
Setting distance L (mm in)

600 600
23.622 23.622 400 400
15.748 15.748
400 STD White 400 STD White 300 STD White 300 STD White Semi-custom
non-glossy paper
15.748 non-glossy paper 15.748 11.811 non-glossy paper 11.811 non-glossy paper fibers
ℓ ℓ ℓ ℓ
200 200
L L 7.874 L 7.874 L
200 200
7.874 Fiber 7.874 Fiber Fiber Fiber
H-SP head H-SP head 100 H-SP head 100 H-SP head
Up 3.937 3.937 Up Fiber
0
Left Right
0 Down
0
Left Right
0
Down Dimensions
150
5.906
100 50
3.937 1.969
0 50 100
1.969 3.937
150
5.906
150
5.906
100 50
3.937 1.969
0 50 100
1.969 3.937
150
5.906
150
5.906
100 50
3.937 1.969
0 50 100
1.969 3.937
150
5.906
150
5.906
100 50
3.937 1.969
0 50 100
1.969 3.937
150
5.906 Thru-beam
Type
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Retroreflective
Type
Reflective
FD-31W Reflective type FD-32G Reflective type Type
FDA256 FDA256
Horizontal direction
FDA262 Vertical direction
FDA262 Others

400 400 800


15.748 HYPR 15.748 HYPR 31.496 HYPR
Setting distance L (mm in)
Setting distance L (mm in)

Amplifiers
Setting distance L (mm in)

300 300 600


11.811 11.811 23.622
FX-500
STD STD STD series
200 White 200 White 400 White
7.874 non-glossy paper 7.874 non-glossy paper 15.748 non-glossy paper FX-100
ℓ ℓ ℓ series
H-SP
H-SP L H-SP L L
100 100 200
3.937 Fiber 3.937 Fiber 7.874 Fiber
head head head
Up
Left Right Left Right
0 0 Down
0 INDEX
60 40 20 0 20 40 60 60 40 20 0 20 40 60 200 100 0 100 200
2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 7.874 3.937 3.937 7.874
Left Center Right Down Center Up Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FDA233
86

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No.
FD-32GX Reflective type FD-40 Reflective type
Fiber
Selection
Guide
Horizontal direction Vertical direction
800 800 800
Model 31.496 31.496 31.496
HYPR HYPR HYPR
Choose
by shape/

Setting distance L (mm in)


application

Setting distance L (mm in)


600 600 600
Setting distance L (mm in)

23.622 23.622 23.622


How to read
Model No White
Earlier models 400 STD 400 STD non-glossy paper 400 STD White
comparison 15.748 White
15.748 15.748 non-glossy paper
table non-glossy paper ℓ
ℓ ℓ
H-SP L
L L
200 200 Fiber 200
7.874 Fiber 7.874 7.874 Fiber
head head head
H-SP H-SP
Up
Fibers 0
Left Right
0
Left Right
0 Down
200 100 0 100 200 150 100 50 0 50 100 150 150 100 50 0 50 100 150
Super 7.874 3.937 3.937 7.874 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906
Quality Left Center Right Left Center Right Down Center Up
Threaded Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Type
Square Head FD-41 Reflective type FD-41S Reflective type
Type FDA261
Cylindrical
FDA234
Horizontal direction Vertical direction Horizontal direction Vertical direction
Type FDA261
600 600 600 600
White non-glossy paper
Sleeve 23.622 HYPR 23.622 HYPR 23.622 HYPR 23.622 HYPR ℓ
500 500 500 500
Flat
L
19.685 19.685 19.685 19.685
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Type Fiber
head
400 400 400 400
Small 15.748 15.748 15.748 15.748 Up
Spot STD STD STD STD
Down
300 White 300 White 300 White 300
Narrow 11.811 non-glossy paper 11.811 non-glossy paper 11.811 non-glossy paper 11.811
Beam 200

200

200

200
Wide 7.874 L 7.874 L 7.874 H-SP L 7.874 H-SP
Beam 100
Fiber
head 100
Fiber
head 100
Fiber
head 100
H-SP H-SP
Convergent 3.937 3.937 Up 3.937 3.937
Reflective
Type Left Right Down Left Right
0 0 0 0
150 100 50 0 50 100 150 150 100 50 0 50 100 150 100 50 0 50 100 100 50 0 50 100
Retroreflective 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 3.937 1.969 1.969 3.937 3.937 1.969 1.969 3.937
Type Left Center Right Down Center Up Left Center Right Down Center Up
Chemical / Oil- Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
resistant
Heat-
resistant FD-41SW FDA258 Reflective type
FDA258 FD-41W Reflective type
Vacuum- FDA223 FDA223
resistant Horizontal direction Vertical direction Horizontal direction Vertical direction
Liquid Leak / 400 400 1,000 1,000
Liquid Detection 15.748 15.748 39.370 39.370
HYPR HYPR HYPR HYPR

800 800
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)

300 300 31.496 31.496


Setting distance L (mm in)

11.811 11.811
Fiber 600 600
Options 23.622 23.622
200 STD 200 STD STD White STD White
7.874 White non-glossy paper 7.874 White non-glossy paper non-glossy paper non-glossy paper
ℓ ℓ 400 ℓ 400 ℓ
15.748 15.748
L L L L
Semi-custom 100
Fiber
100
Fiber 200 Fiber 200 Fiber
3.937 3.937
fibers H-SP head H-SP head 7.874 H-SP head 7.874 H-SP head
Up Up
Left Right Down Left Right Down
0 0 0 0
40 20 0 20 40 40 20 0 20 40 150 100 50 0 50 100 150 150 100 50 0 50 100 150
1.575 0.787 0.787 1.575 1.575 0.787 0.787 1.575 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906
Fiber Left Center Right Down Center Up Left Center Right Down Center Up
Dimensions Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Thru-beam
Type
Retroreflective FD-42G Reflective type FD-42GW Reflective type FD-60 Reflective type
Type FDA224 FDA218
FDA224 FDA218
Reflective Horizontal direction Vertical direction
Type
800 800 2,000 2,000
31.496 31.496 78.740 78.740
Others HYPR HYPR HYPR HYPR
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)

600 600 1,500 1,500


Setting distance L (mm in)

23.622 23.622 59.055 59.055

Amplifiers 400 STD


White
400 STD
White
1,000 STD White 1,000 STD White
15.748 15.748 39.370 non-glossy paper 39.370 non-glossy paper
non-glossy paper non-glossy paper
FX-500 ℓ ℓ ℓ ℓ
series H-SP H-SP
L L L L
200 200 500 500
FX-100 7.874 Fiber 7.874 Fiber 19.685 Fiber
head 19.685 Fiber
head
head head
series H-SP H-SP
Up
Left Right
0
Left Right Left Right 0.000 Down
0 0 0
200 100 0 100 200 100 50 0 50 100 400 200 0 200 400 400 200 0 200 400
7.874 3.937 3.937 7.874 3.937 1.969 1.969 3.937 15.748 7.874 7.874 15.748 15.748 7.874 0.000 7.874 15.748
Left Center Right Left Center Right Left Center Right Down Center Up
INDEX Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FDA203
FDA235 FDA260 FDA260
87

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Tough
Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No. Fiber

FD-61 Reflective type FD-61G Reflective type


Fiber
Horizontal direction Vertical direction Selection
Guide
1,500 1,500 1,200
59.055 59.055 47.244 Model
HYPR HYPR HYPR
1,000 Choose
39.370 by shape/
application
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)
1,000 1,000 800 How to read
39.370 39.370 31.496 Model No.
White White White
STD non-glossy STD non-glossy 600 STD non-glossy Earlier models
paper paper 23.622 paper comparison
ℓ table
ℓ ℓ
500 500 400
19.685 L 19.685 L 15.748 H-SP L
Fiber Fiber Fiber
H-SP head H-SP head 200 head
Up 7.874
0 Left Right 0 Down Left Right Fibers
0
600 400 200 0 200 400 600 600 400 200 0 200 400 600 600 400 200 0 200 400 600
23.622 15.748 7.874 7.874 15.748 23.622 23.622 15.748 7.874 7.874 15.748 23.622 23.622 15.748 7.874 7.874 15.748 23.622 Super
Left Center Right Down Center Up Left Center Right Quality
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Threaded
Type
FD-61S Reflective type FD-61W Reflective type Square Head
FDA259 FDA200 Type
Horizontal direction FDA259
Vertical direction Horizontal direction Vertical direction Cylindrical
Type
1,500 1,500 1,000 1,000
59.055 HYPR 59.055 HYPR 39.370 HYPR 39.370 HYPR Sleeve
800 800 Flat
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

31.496 31.496
Type
1,000 1,000
39.370 39.370 600 STD 600 Small
STD White STD
White
non-glossy
23.622 23.622
STD Spot
White White
Narrow
non-glossy paper paper non-glossy paper non-glossy paper
400 400
500

500

15.748

15.748
ℓ Beam
Wide
19.685 L 19.685 L L L
Fiber
head
Fiber
head
200 Fiber 200 Fiber
head Beam
H-SP H-SP 7.874 H-SP head 7.874 H-SP
Up Up Convergent
Left Right Reflective
Type
Left Right Down Down
0 0 0 0
400 200 0 200 400 400 200 0 200 400 150 100 50 0 50 100 150 150 100 50 0 50 100 150
15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 Retroreflective
Left Center Right Down Center Up Left Center Right Down Center Up Type
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Chemical / Oil-
resistant
Heat-
FD-62 Reflective type FD-64X Reflective type resistant
FDA222 FDA216 Vacuum-
FDA222
Horizontal direction Vertical direction FDA216
Horizontal direction Vertical direction resistant

2,000 2,000 800 800 Liquid Leak /


78.740 78.740 31.496 31.496 Liquid Detection
HYPR HYPR HYPR HYPR
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

1,500 1,500 600 600


59.055 59.055 23.622 23.622
Fiber
White Options
1,000 STD White 1,000 STD White 400 STD White 400 STD non-glossy
39.370 non-glossy paper 39.370 non-glossy paper 15.748 non-glossy paper 15.748 paper
ℓ ℓ ℓ ℓ
L L L L
500
19.685 Fiber
500
19.685 Fiber
200
7.874 Fiber
200
7.874 Fiber Semi-custom
head head head head fibers
H-SP H-SP H-SP H-SP
Up Up
Left Right Down Left Right Down
0 0 0 0
600 400 200 0 200 400 600 600 400 200 0 200 400 600 300 200 100 0 100 200 300 300 200 100 0 100 200 300
23.622 15.748 7.874 7.874 15.748 23.622 23.622 15.748 7.874 7.874 15.748 23.622 11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811
Left Center Right Down Center Up Left Center Right Down Center Up Fiber
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Dimensions
Thru-beam
Type
FD-A16 Reflective type FD-AL11 FDA248 Reflective type Retroreflective
FDA220 FDA248 Type
FDA220
Horizontal direction Vertical direction Horizontal direction Vertical direction Reflective
Type
250 250 800 800
9.843 9.843 31.496 31.496
HYPR HYPR Others
STD STD
200 200
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

600 600
Setting distance L (mm in)

7.874 7.874
23.622 23.622
150 150
5.906 5.906 White
White non-glossy 400 STD 400 STD
White Amplifiers
non-glossy paper paper 15.748 White 15.748
non-glossy
200mm 200mm paper
100 100 non-glossy
3.937
H-SP
7.874in 3.937
H-SP
7.874in paper FX-500
ℓ series
ℓ ℓ ℓ
200 H-SP 200 H-SP
50 L 50 L 7.874 L 7.874 3.6mm FX-100
0.142in L
1.969 Fiber 1.969 Fiber Fiber series
head head head Fiber
head
0 0 0 0
60 40 20 0 20 40 60 60 40 20 0 20 40 60 300 200 100 0 100 200 300 300 200 100 0 100 200 300
2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) INDEX

FDA225 FDA252 FDA252


FDA225
88

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No.
FD-E13 Reflective type FD-E23 Reflective type FD-EG30 Reflective type
Fiber
Selection
Guide
Horizontal direction Vertical direction
60 60 200 200
Model 2.362 2.362 7.874 7.874
HYPR HYPR HYPR HYPR
Choose 50 50
by shape/ 1.969 1.969
Setting distance L (mm in)
Setting distance L (mm in)

application

Setting distance L (mm in)


Setting distance L (mm in)
150 150
5.906 5.906
How to read 40 White 40 White
Model No 1.575 non-glossy
paper
1.575 non-glossy
paper White
White
Earlier models 30 STD 200mm 30 STD 200mm 100 STD non-glossy 100 STD non-glossy
paper
comparison 1.181 7.874in 1.181 7.874in 3.937 paper 3.937
table ℓ ℓ 200mm 200mm
20 20 7.874in 7.874in
H-SP H-SP H-SP H-SP ℓ
0.787 L 0.787 L ℓ
Fiber Fiber
50 50
10 head 10 head 1.969 L 1.969 L
0.394 0.394 Up Fiber Fiber
head
Fibers Left Right Down 0
head
0
0 0
15 10 5 0 5 10 15 15 10 5 0 5 10 15 40 20 0 20 40 60 40 20 0 20 40 60
Super 0.591 0.394 0.197 0.197 0.394 0.591 0.591 0.394 0.197 0.197 0.394 0.591 1.575 0.787 0.787 1.575 2.362 1.575 0.787 0.787 1.575 2.362
Quality Left Center Right Down Center Up
Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Threaded Operating point ℓ (mm in)
Type
Square Head
Type FD-EG30S FDA242
Reflective type FD-EG31 FDA242
Reflective type FD-H13-FM2 Reflective type FDA246
Cylindrical FDA243
Type 200 100
7.874 HYPR 3.937 HYPR White non-glossy paper
Sleeve ℓ
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)

80 1,000 L
Flat 150 3.150 39.370 Fiber
Type 5.906 head
60
Small White 2.362 White HYPR
Spot 100 STD non-glossy STD non-glossy
3.937 paper paper STD
Narrow 200mm 40 200mm 500
Beam H-SP 7.874in 1.575 H-SP
7.874in 19.685
ℓ ℓ H-SP
Wide
50
1.969 20 L
Beam
L
Fiber
0.787 Fiber
Convergent head head
Reflective 0 0 0
Type 60 40 20 0 20 40 60 30 20 10 0 10 20 30 400 200 0 200 400
Retroreflective 2.362 1.575 0.787 0.787 1.575 2.362 1.181 0.787 0.394 0.394 0.787 1.181 15.748 7.874 7.874 15.748
Type Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Chemical / Oil-
resistant
Heat-
resistant FD-H18-L31   Reflective type FD-H20-21 Reflective type FD-H20-M1 Reflective type
Vacuum-
resistant Horizontal direction Vertical direction
Liquid Leak / 80
Transparent glass
80
Liquid Detection 3.150
100mm, (t=0.7mm)
3.150 Transparent glass White non-glossy paper
100mm,(t=0.7mm) ℓ
3.937in, (t=0.028in) 3.937in,(t=0.028in) HYPR
Setting distance L (mm in)
Setting distance L (mm in)

HYPR 1,000 L 1,000


Setting distance L (mm in)

Setting distance L (mm in)

60 60 39.370 39.370
2.362 ℓ 2.362 ℓ Fiber
4mm L HYPR Emitter L head
Fiber 0.157in HYPR
Options 40 40
1.575 1.575 STD STD
STD
500 STD 500 White
19.685 19.685 non-glossy paper
20 20 H-SP ℓ
Semi-custom 0.787 H-SP 0.787 H-SP H-SP
L
fibers Fiber
head
0 0 0 0
4 2 0 2 4 4 2 0 2 4 200 100 0 100 200 200 100 0 100 200
0.157 0.079 0.079 0.157 0.157 0.079 0.079 0.157 7.874 3.937 3.937 7.874 7.874 3.937 3.937 7.874
Left Center Right Left Center Right Left Center Right
Fiber Operating point ℓ (mm in)
Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in)
Operating point ℓ (mm in)
Dimensions
Thru-beam
Type
FD-H25-L43 Reflective type
Retroreflective
Type
Horizontal direction Vertical direction
Reflective
Type 40 40
1.575 Transparent glass 100mm, (t=0.7mm) 1.575 Transparent glass
100mm, (t=0.7mm)
Others
HYPR 3.937in, (t=0.028in)
HYPR 3.937in, (t=0.028in)
Setting distance L (mm in)
Setting distance L (mm in)

30 4.5mm ℓ L 30
1.181 0.177in 1.181 Emitter ℓ L
STD
STD
20 20
Amplifiers 0.787 0.787 H-SP
FX-500 H-SP
series 10 10
0.394 0.394
FX-100
series
0 0
4 2 0 2 4 4 2 0 2 4
0.157 0.079 0.079 0.157 0.157 0.079 0.079 0.157
Left Center Right Down Center Up
INDEX Operating point ℓ (mm in) Operating point ℓ (mm in)
89

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Reflective type Sensing field Sensing characteristics are listed in the alphabetic order of the Model No. Tough
Fiber
(Models with same sensing characteristics are grouped together.)
FD-H25-L45 Reflective type FD-H30-L32 Reflective type
Fiber
Horizontal direction Vertical direction Horizontal direction Vertical direction Selection
Guide
80 80
Transparent glass Transparent glass 3.150 3.150 Transparent glass Model
HYPR 100mm, (t=0.7mm) HYPR 100mm, (t=0.7mm) Transparent glass
100mm, (t=0.7mm)
3.937in, (t=0.028in) 3.937in, (t=0.028in) 100mm
3.937in, (t=0.028in) Choose

Setting distance L (mm in)


by shape/

Setting distance L (mm in)


40 40 3.937in

Setting distance L (mm in)


(t=0.7mm) application
Setting distance L (mm in)

1.575 1.575 60 60
4.5mm ℓ L STD Emitter ℓ L 2.362 (t=0.028in) 2.362 ℓ
0.177in HYPR
Emitter L How to read
HYPR
ℓ Model No.
STD 40
L
40 Earlier models
H-SP STD comparison
1.575 STD 1.575
20 20 table
0.787 H-SP 0.787
H-SP
20 H-SP 20
0.787 0.787

0 0 0
Fibers
0
4 2 0 2 4 4 2 0 2 4 2 1 0 1 2 2 1 0 1 2
0.157 0.079 0.079 0.157 0.157 0.079 0.079 0.157 0.079 0.039 0.039 0.079 0.079 0.039 0.039 0.079 Super
Left Center Right Down Center Up Left Center Right Down Center Up Quality
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Threaded
Type
Square Head
FD-H30-L32V-S Reflective type FD-H35-20S Reflective type FD-H35-M2 Reflective Type
FD-H35-M2S6 type Cylindrical
Horizontal direction Vertical direction Type

Transparent glass White non-glossy paper


800
White non-glossy paper Sleeve
Transparent glass 31.496
100mm, (t=0.7mm) ℓ ℓ
HYPR 100mm, (t=0.7mm)
3.937in, (t=0.028in) Flat
Type
20 3.937in, (t=0.028in) 20 1,000 L L

Setting distance L (mm in)


Setting distance L (mm in)
Setting distance L (mm in)
Setting distance L (mm in)

0.787 0.787 39.370 600


HYPR ℓ
Small

Fiber head 23.622 Fiber head
Emitter L
Spot
L
HYPR HYPR
STD STD 400 Narrow
500
15.748 STD Beam
10 10
0.394 H-SP 0.394 19.685 STD Wide
H-SP H-SP 200 Beam
7.874 Convergent
H-SP
Reflective
Type
0
0 0 0
200 100 0 100 200 Retroreflective
2
0.079
1
0.039
0 1
0.039
2
0.079
2
0.079
1
0.039
0 1
0.039
2
0.079
400
15.748
200
7.874
0 200
7.874
400
15.748 7.874 3.937 3.937 7.874 Type
Left Center Right Down Center Up Left Center Right Left Center Right Chemical / Oil-
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) resistant
Heat-
resistant
FD-L10 Reflective type FD-L11 Reflective type Vacuum-
resistant
Horizontal direction Vertical direction Horizontal direction Vertical direction Liquid Leak /
8 8 15 15 Liquid Detection
0.315 0.315 Transparent glass 0.591 Transparent glass 0.591 Transparent glass
HYPR HYPR 100mm, (t=0.7mm) HYPR 100mm HYPR 100mm
3.937in, (t=0.028in) 3.937in 3.937in
STD STD STD (t=0.7mm) STD (t=0.7mm)

Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

6 6 2mm (t=0.028in) (t=0.028in)


0.236 0.236 0.079in L 10 ℓ 10 ℓ Fiber
H-SP H-SP 0.394 H-SP 0.394 H-SP 2mm Options
L 0.079in L
4 Transparent 4
0.157 glass 0.157
100mm
3.937in 5 5
(t=0.7mm)
0.197 0.197 Semi-custom
2
0.079
(t=0.028in) 2
0.079 fibers

L
0 0 0 0
3 2 1 0 1 2 3 3 2 1 0 1 2 3 4 2 0 2 4 4 2 0 2 4
0.118 0.079 0.039 0.039 0.079 0.118 0.118 0.079 0.039 0.039 0.079 0.118 0.157 0.079 0.079 0.157 0.157 0.079 0.079 0.157 Fiber
Left Center Right Down Center Up Left Center Right Down Center Up Dimensions
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Thru-beam
Type

FDA232 Retroreflective
FD-L12W Reflective type FD-L20H FDA231 FDA231
Reflective type Type
FDA232 Reflective
Horizontal direction Vertical direction Horizontal direction Vertical direction Type
15
0.591 Transparent glass
15
0.591 Transparent glass
50
1.969
50
1.969
Others
HYPR 100mm HYPR 100mm
HYPR HYPR
3.937in 3.937in
(t=0.7mm) 40 40
Setting distance L (mm in)

(t=0.7mm)
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)

(t=0.028in) (t=0.028in) 1.575 1.575


10 ℓ 10 ℓ STD STD
0.394 STD 0.394 STD 1.5mm 30
L 0.059in L 1.181
30 Amplifiers
White 1.181
non-glossy paper White non-glossy paper FX-500
20 200mm 200mm
0.787 7.874in
20 series
5 H-SP 5 H-SP 0.787 7.874in

0.197 0.197 H-SP H-SP ℓ FX-100
10 L 10 L series
0.394 Fiber 0.394
head Fiber
head
0 0 0
1 0.5 0 0.5 1 1 0.5 0 0.5 1 15 10 5 0 5 10 15 0
0.039 0.020 0.020 0.039 0.039 0.020 0.020 0.039 0.591 0.394 0.197 0.197 0.394 0.591 15 10 5 0 5 10 15
Down Center Up 0.591 0.394 0.197 0.197 0.394 0.591 INDEX
Left Center Right Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FDA226 FDA226
FDA251 FDA251
90

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No.
FD-L21 Reflective type FD-L21W Reflective type
Fiber
Selection
Guide
Horizontal direction Vertical direction Horizontal direction Vertical direction
20 20 20 20
Model 0.787 Transparent glass 0.787 0.787 Transparent glass 0.787
HYPR 200mm, (t=2.0mm) HYPR HYPR 200mm, (t=2.0mm)
HYPR
Choose 7.874in, (t=0.079in) 7.874in, (t=0.079in)
by shape/ ℓ STD STD

Setting distance L (mm in)


Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)


application 15 STD 15 STD 15 15
0.591 0.591 0.591 0.591
How to read
L L
H-SP H-SP
Model No H-SP Emitter H-SP
Transparent
glass
Earlier models 10 10 200mm 10 10 Transparent
comparison 0.394 0.394 7.874in 0.394 0.394
glass
table (t=2.0mm) 200mm
(t=0.079in) 7.874in
(t=2.0mm)
5 5 ℓ 5 5 (t=0.079in)
0.197 0.197 3mm 0.197 0.197
0.118in L ℓ
3mm
Fiber 0.118in L
Fibers head 0
0 0 0
6 4 2 0 2 4 6 3 2 1 0 1 2 3 4 2 0 2 4 2 1 0 1 2
Super 0.236 0.157 0.079 0.079 0.157 0.236 0.118 0.079 0.039 0.039 0.079 0.118 0.157 0.079 0.079 0.157 0.079 0.039 0.039 0.079
Quality Left Center Right Down Center Up Left Center Right Down Center Up
Threaded Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Type
Square Head
Type FD-L22A Reflective type FD-L23 FDA228 Reflective type
FDA228
FDA227
Cylindrical FDA227
Type Horizontal direction Vertical direction Horizontal direction Vertical direction
Sleeve 35 35 35 Transparent
35
1.378 HYPR 1.378 HYPR 1.378 HYPR glass 1.378 HYPR
Flat 30 30 30 100mm 30
Type 1.181 STD 1.181 STD 1.181 STD 3.937in 1.181 STD
Setting distance L (mm in)
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


(t=0.7mm)
25 25 25 25
Small 0.984 0.984 0.984
(t=0.028in)
0.984
Spot H-SP H-SP H-SP ℓ H-SP
20 20 20 20
Narrow 0.787 0.787 Transparent
glass
0.787 L 0.787 Transparent
glass
Beam 15 15 100mm 15 15 100mm
Transparent glass
0.591 0.591 0.591 0.591
Wide 100mm, (t=0.7mm) 3.937in 3.937in
(t=0.7mm) (t=0.7mm)
Beam 10 3.937in, (t=0.028in) 10 (t=0.028in) 10 10 (t=0.028in)
0.394 ℓ 0.394 0.394 0.394
Convergent ℓ ℓ
Reflective 5 L 5 2.5mm 5 5 2.5mm
Type 0.197 0.197 0.098in L 0.197 0.197 0.098in L
Retroreflective 04 04 0 06
Type 2 0 2 4 2 0 2 4 6 4 2 0 2 4 6 4 2 0 2 4 6
0.157 0.079 0.079 0.157 0.157 0.079 0.079 0.157 0.236 0.157 0.079 0.079 0.157 0.236 0.236 0.157 0.079 0.079 0.157 0.236
Chemical / Oil- Left Center Right Down Center Up Left Center Right Down Center Up
resistant Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Heat-
resistant
Vacuum- FD-L30A Reflective type FD-L31A Reflective type
FDA205
resistant FDA201 FDA201
FDA205
Liquid Leak / Horizontal direction Vertical direction Horizontal direction Vertical direction
Liquid Detection
50 50 40 40
1.969 1.969 1.575 Transparent glass 1.575
HYPR HYPR HYPR 100mm, (t=0.7mm) HYPR
3.937in, (t=0.028in)
40 STD 40 STD STD ℓ STD
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

1.575 1.575 30 30
Fiber 1.181 L 1.181
Options 30 H-SP 30 H-SP H-SP H-SP
1.181 Transparent 1.181 Transparent
20 20 glass
glass Transparent glass 0.787 0.787
20 100mm 20 100mm 100mm
0.787 3.937in 0.787 3.937in 3.937in
Semi-custom (t=0.7mm) (t=0.7mm) (t=0.7mm)
fibers 10
(t=0.028in)
10
(t=0.028in) 10 10 (t=0.028in)
ℓ ℓ 0.394 0.394 ℓ
0.394 0.394 2.5mm 3mm
L L 0.118in L
0.098in
0 0 0 0
6 4 2 0 2 4 6 6 4 2 0 2 4 6 6 4 2 0 2 4 6 6 4 2 0 2 4 6
Fiber 0.236 0.157 0.079 0.079 0.157 0.236 0.236 0.157 0.079 0.079 0.157 0.236 0.236 0.157 0.079 0.079 0.157 0.236 0.236 0.157 0.079 0.079 0.157 0.236
Dimensions Left Center Right Down Center Up Left Center Right Down Center Up
Thru-beam Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Type
Retroreflective FDA202
Type FD-L32H Reflective type FD-R60 FDA229
Reflective type
Reflective FDA229
Type FDA202
Horizontal direction Vertical direction Horizontal direction Vertical direction
Others 120
Transparent glass
120 1,200 1,200
4.724 HYPR 4.724 HYPR 47.244 HYPR 47.244 HYPR
100mm
100 3.937in 100 Transparent 1,000 1,000
(t=0.7mm)
Setting distance L (mm in)
Setting distance L (mm in)

3.937 3.937 39.370 39.370


Setting distance L (mm in)

glass
Setting distance L (mm in)

(t=0.028in) 100mm
80 STD R edge(R0.35 R0.014) 80 STD 3.937in 800 800
Amplifiers 3.150 3.150 (t=0.7mm) 31.496 31.496
(t=0.028in) White White
60 60 600 STD non-glossy 600 STD non-glossy
ℓ R edge
FX-500 2.362 L 2.362 (R0.35 23.622 paper 23.622 paper
series R0.014) ℓ ℓ
40 40 400 400
FX-100 1.575 1.575 15.748 L 15.748 L
series ℓ L Fiber Fiber
20 20 200 H-SP head 200 H-SP head
0.787 0.787 7.874 7.874 Up
Left Right Down
0 0 0 0
10 5 0 5 10 10 5 0 5 10 300 200 100 0 100 200 300 300 200 100 0 100 200 300
0.394 0.197 0.197 0.394 0.394 0.197 0.197 0.394 11.811 7.874 3.937 3.937 7.874 11.811 11.811 7.874 3.937 3.937 7.874 11.811
INDEX Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FDA230 FDA240 FDA240


FDA230
91

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Tough
Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No. Fiber

FD-R61Y Reflective type FD-S21 Reflective type


Fiber
Horizontal direction Vertical direction Horizontal direction Vertical direction Selection
Guide
1,000 1,000 200 200
39.370 39.370 7.874 7.874 Model
HYPR HYPR HYPR HYPR
Choose
800 800 by shape/

Setting distance L (mm in)

Setting distance L (mm in)


application

Setting distance L (mm in)


Setting distance L (mm in)

31.496 31.496 150 150


5.906 5.906
White
White How to read
600 STD 600 non-glossy
non-glossy
paper Model No.
23.622 23.622 paper
White STD White 100 STD
200mm 100 STD 200mm Earlier models
non-glossy paper non-glossy paper 3.937 3.937 7.874in comparison
400 ℓ 400 ℓ
7.874in
ℓ table
15.748 15.748 ℓ
L H-SP H-SP L
L L
Fiber
50 50
200 Fiber 200 1.969 1.969 Fiber
7.874 head 7.874 head Fiber head head
H-SP H-SP
Up Up
Left Right Down 0 Left Right
0 Down Fibers
0 0
150 100 50 0 50 100 150 150 100 50 0 50 100 150 60 40 20 0 20 40 60 60 40 20 0 20 40 60
5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 Super
Left Center Right Down Center Up Left Center Right Down Center Up Quality
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Threaded
Type
Square Head
FD-S30 Reflective type FD-S31 FDA245 Reflective type Type
FDA216 FDA245
Cylindrical
FDA216
Horizontal direction Vertical direction Horizontal direction Vertical direction Type
800 800 600 600 Sleeve
31.496 HYPR 31.496 HYPR 23.622 HYPR 23.622 HYPR
500 500 Flat
Type
Setting distance L (mm in)

19.685 19.685
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

600 600
23.622 23.622 400 400 Small
White
non-glossy 15.748 15.748 Spot
White White
400 STD non-glossy 400 STD paper
300 STD non-glossy
300 STD Narrow
15.748 paper
15.748 ℓ 11.811
paper
11.811 White non-glossy paper Beam
ℓ ℓ

Wide
L
200 L 200
Beam
L L
200 200 Fiber 7.874 7.874
Fiber head Fiber Fiber
7.874 head 7.874 100 head 100 head Convergent
H-SP H-SP Up
3.937
H-SP
3.937
H-SP Reflective
Down
Up Type
Left Right Left Right
Retroreflective
0 Down
0 0 0
150 100 50 0 50 100 150 150 100 50 0 50 100 150 150 100 50 0 50 100 150 150 100 50 0 50 100 150 Type
5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906
Left Center Right Down Center Up Left Center Right Down Center Up Chemical / Oil-
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) resistant
Heat-
resistant
FD-S32 FDA263 Reflective type
FDA263 FD-S32W FDA257 Reflective type Vacuum-
FDA257 resistant
Horizontal direction Vertical direction Horizontal direction Vertical direction Liquid Leak /
Liquid Detection
1,500 1,500 1,000 1,000
59.055 HYPR 59.055 HYPR 39.370 HYPR 39.370 HYPR

800 800
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

31.496 31.496
Fiber
1,000 1,000
39.370 39.370 600 600
Options
23.622 23.622
STD White STD White STD White
STD White
non-glossy paper non-glossy paper non-glossy paper non-glossy paper
ℓ ℓ 400 ℓ
400 ℓ
500 500 15.748 15.748
19.685 L 19.685 L L L Semi-custom
200 200 fibers
Fiber head Fiber head 7.874 Fiber head 7.874 Fiber head
H-SP H-SP H-SP H-SP
Up Up
Left Right Down Left Right Down
0 0 0 0
400 200 0 200 400 400 200 0 200 400 150 100 50 0 50 100 150 150 100 50 0 50 100 150
15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906 Fiber
Left Center Right Down Center Up Left Center Right Down Center Up Dimensions
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Thru-beam
Type
Retroreflective
FD-S33GW Reflective type FD-S60Y Reflective type
FDA219 Type
FDA221
FDA221 FDA219 Reflective
Horizontal direction Vertical direction Type
800
White non-glossy paper
600 600 Others
31.496 HYPR 23.622 HYPR 23.622 HYPR

L
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

600
23.622 Fiber head 400 400
Left Right
15.748 15.748 Amplifiers
400 STD STD White STD White
15.748 non-glossy paper non-glossy paper FX-500
ℓ ℓ series
H-SP 200 200
200 7.874 L 7.874 L FX-100
7.874 series
H-SP Fiber head H-SP Fiber head
Up
0 Left Right 0 Down
0
100 50 0 50 100 50 25 0 25 50 50 25 0 25 50
3.937 1.969 1.969 3.937 1.969 0.984 0.984 1.969 1.969 0.984 0.984 1.969
Left Center Right Left Center Right Down Center Up INDEX
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FDA236 FDA221
FDA221
92

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber Reflective type Sensing field  Sensing characteristics are listed in the alphabetic order of the Model No.
FD-V30 Reflective type FD-V30W Reflective type
Fiber
Selection Horizontal direction Vertical direction Horizontal direction Vertical direction
Guide
250 250 100 100
Model 9.843 HYPR 9.843 HYPR 3.937 HYPR 3.937 HYPR
Choose 200 200 80 80
by shape/
Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


application 7.874 7.874 3.150 3.150
How to read 150 150 60 60
Model No 5.906 5.906 2.362 2.362
White
STD White STD STD STD non-glossy
Earlier models non-glossy
White paper
comparison paper
non-glossy paper
White non-glossy paper 200mm
table 100
200mm
100 200mm 40
200mm
40
7.874in
3.937 H-SP 3.937 H-SP 7.874in 1.575 H-SP 1.575 H-SP
7.874in 7.874in ℓ
ℓ ℓ
ℓ L
50 50 L 20 20
1.969 L 1.969 0.787 L 0.787
Fiber Fiber Fiber head
Fibers 0
head
0
Fiber head
0
head
0
80 60 40 20 0 20 40 60 80 80 60 40 20 0 20 40 60 80 20 10 0 10 20 20 10 0 10 20
Super 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 0.787 0.394 0.394 0.787 0.787 0.394 0.394 0.787
Quality Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Threaded
Type
Square Head FDA238
Type FD-V50 Reflective type
FDA237 FD-Z20HBW
FDA238 Reflective type
FDA237
Cylindrical
Type Horizontal direction Vertical direction Horizontal direction Vertical direction
Sleeve 400 ℓ 400 400
White non-glossy paper
400
White non-glossy paper
15.748 White 15.748 HYPR 15.748 HYPR 15.748 HYPR
L non-glossy paper ℓ ℓ
Flat 3.5mm
Type L 0.138in L
Setting distance L (mm in)

Setting distance L (mm in)

Fiber head
Setting distance L (mm in)

Setting distance L (mm in)


300 300 300 300
Small 11.811 11.811 11.811 Fiber 11.811 Fiber
HYPR head head
Spot
Narrow 200 STD 200 STD 200 STD 200 STD
Beam 7.874 7.874 White 7.874 7.874
H-SP H-SP non-glossy
Wide paper
H-SP H-SP
Beam 100 100 ℓ 100 100
Convergent 3.937 3.937 L 3.937 3.937
Reflective
Type
Fiber head
Retroreflective 0 0 0 0
Type
100 50 0 50 100 100 50 0 50 100 60 40 20 0 20 40 60 60 40 20 0 20 40 60
3.937 1.969 1.969 3.937 3.937 1.969 1.969 3.937 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362
Chemical / Oil- Left Center Right Down Center Up Left Center Right Down Center Up
resistant Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

Heat-
resistant
FDA239
Vacuum- FD-Z20W FDA239 Reflective type FD-Z40HBW FDA249
Reflective type
resistant FDA249
Liquid Leak / Horizontal direction Vertical direction Horizontal direction Vertical direction
Liquid Detection
300 300 800 800
11.811 HYPR 11.811 HYPR 31.496 HYPR 31.496 HYPR
250 250
9.843 9.843
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)
Setting distance L (mm in)

600 600
Fiber 23.622 23.622
200 200
Options 7.874 7.874
150 STD White 150 STD 400 STD 400 STD
5.906 non-glossy 5.906 White 15.748 White 15.748 White
paper non-glossy paper non-glossy non-glossy
100 100 paper paper
Semi-custom 3.937 ℓ 3.937 ℓ ℓ

fibers 3.5mm L
1.2mm
0.047in L
200 H-SP 200 H-SP
4mm
50 0.138in 50 7.874 L 7.874 0.158in L
1.969 H-SP 1.969 H-SP Fiber Fiber
Fiber Fiber
head head head head
0 0 0 0
30 20 10 0 10 20 30 30 20 10 0 10 20 30 150 100 50 0 50 100 150 150 100 50 0 50 100 150
Fiber 1.181 0.787 0.394 0.394 0.787 1.181 1.181 0.787 0.394 0.394 0.787 1.181 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906
Dimensions Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Thru-beam
Type
Retroreflective FDA250
Type FD-Z40W Reflective type FD-Z50HWFDA250 Reflective type
FDA436 FDA346
Reflective
Type Horizontal direction Vertical direction Horizontal direction Vertical direction
Others 800
White non-glossy paper
800 3,000 3,000

31.496 31.496 118.110 White non-glossy paper 118.110 HYPR White non-glossy
ℓ HYPR HYPR L paper

4.0mm L 2,500 2,500
0.158in 98.425 L 98.425 Fiber head
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

600 600
23.622 Fiber head 23.622 2,000 Fiber 2,000
head
Amplifiers HYPR
78.740 78.740
400 400 STD White 1,500 STD 1,500 STD
FX-500 15.748 15.748 non-glossy 59.055 59.055
series STD paper
1,000 1,000
FX-100 200 200
ℓ 39.370 39.370
series 1.2mm L H-SP H-SP
7.874 7.874 0.047in 500 500
H-SP H-SP
Fiber head
19.685 19.685
0 0 0 0
80 60 40 20 0 20 40 60 80 80 60 40 20 0 20 40 60 80 60 40 20 0 20 40 60 60 40 20 0 20 40 60
3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 3.150 2.362 1.575 0.787 0.787 1.575 2.362 3.150 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362
INDEX Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)

FDA241 FDA241
FDA347 FDA347
93

PRECAUTIONS FOR PROPER USE Refer to the “PRO mode operation manual” on our website for details. New product
introduction
Tough
Others Fiber
• Never use this product as a sensing device
for personnel protection. • Our products have been developed / produced for
• In case of using sensing devices for industrial use only.
Fiber
personnel protection, use products which • The specification may not be satisfied in a strong Selection
Guide
meet laws and standards, such as OSHA, magnetic field.
Model
ANSI or IEC etc., for personnel protection • The ultra long distance (U-LG, HYPR) mode is more
applicable in each region or country. likely to be affected by extraneous noise since the Choose
by shape/
sensitivity of that is higher than the other modes. Make application

sure to check the environment before use. How to read


Model No.
Wiring • Do not use during the initial transient time (H-SP, FAST, Earlier models
comparison
• Make sure that the power supply is OFF while adding or STD: 0.5 sec., LONG, U-LG, HYPR: 1 sec.) after the table

removing the amplifiers. power supply is switched ON.


• Note that if a voltage exceeding the reted range is • These sensors are only for indoor use.
applied, or if an AC power supply is directly connected, • Avoid dust, dirt, and steam. Fibers
the product may get burnt or damaged. • Make sure that the product does not come in contact with
Super
• Note that short-circuit of the load or wrong wiring may oil, grease, organic solvents such as thinner, etc., strong Quality
burn or damage the product. acid or alkaline. Threaded
• This product cannot be used in an environment Type
• Do not run the wires together with high-voltage lines or
containing inflammable or explosive gases. Square Head
power lines, or put them in the same raceway. Type
This can cause malfunction due to induction. • Never disassemble or modify this product. Cylindrical
• Verify that the supply voltage variation is within the rating. • This product adopts EEPROM. Settings cannot be done Type

• If power is supplied from a commercial switching a million times or more because of the EEPROM's Sleeve
regulator, ensure that the frame ground (F.G.) terminal of lifetime.
Flat
the power supply is connected to an actual ground. Type
• In case noise generating equipment (switching regulator, Small
Spot
inverter motor, etc.) is used in the vicinity of this
product, connect the frame ground (F.G.) terminal of the Narrow
Beam
equipment to an actual ground. Wide
• Make sure to use the quick-connection cable (optional) Beam
Convergent
for the connection of the controller. Reflective
Type
Extension up to total 100 m 328.084 ft is possible with
Retroreflective
0.3 mm2 or more, cable. Type
However, in order to reduce noise, make the wiring as Chemical / Oil-
short as possible. resistant
• Make sure that stress by forcible bending or pulling is not Heat-
resistant
applied to the sensor cable joint and fiber cable.
Vacuum-
resistant
Liquid Leak /
Liquid Detection

Fiber
Options

Semi-custom
fibers

Fiber
Dimensions
Thru-beam
Type
Retroreflective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
94

New product PRECAUTIONS FOR PROPER USE


introduction
Tough Abstract from “PRO MODE OPERATION MANUAL” Part description Symbol explanation
Fiber
SET
SET key (Confirm) : Press the SET key.
UP (+) key (Select) DOWN (-) key (Select) +, -
: Press the UP (+) key or
MODE key DOWN (-) key.
Fiber (Select, cancel) Automatic
Selection : Automatically move to next
Guide
MODE indicator: PRO (Yellow)
Model PRO mode
Choose Response time
by shape/
application
<PRO1> SET setting (Note 1) SET 250μs or less +, - 2ms or less +, - 4ms or less +, -
Data bank
How to read <PRO3> SET loading setting SET 1 ch +, -
YES
+, -
good
<PRO5>
Model No +, -
+, - +, -
+, -
Changeable 1 to
Earlier models Blink Blinks
comparison 60μs or less 25μs or less 24ms or less +, - 8ch in + or - Automatic
3 times
table Notes: 1) Display of incident light intensity depends on the re-
Data bank saving
sponse time.
setting YES good
+, - SET 1 ch +, - +, -
Response time Incident light intensity
“ ”, “ ”, “ ” Max. 4,000 Changeable 1 to
Blink Blinks
“ ” Max. 8,000 +, - 8ch in + or - Automatic
3 times
Fibers “ ”, “ ” Max. 9,999
Back up setting Back up ON Back up OFF
SET +, -
Super OFF-delay ON-delay +, - +, -
Quality Timer setting SET No timer +, - timer +, - timer
+, -
Threaded
Type Only displayed in FX-502□
+, - +, -
+, - +, -
Input / output setting SET Sensing output 2 +, - External input
Square Head ON-delay / One-shot ON / OFF-delay
Type One-shot timer timer timer
(Except sensing output 2) (Except sensing output 2)
Cylindrical Notes: 2) When using time, be sure to set the time range.
Type +, - Since the setting time depends on timer range as table
below, set the setting time after selecting the timer YES good
SET Copy setting
Sleeve range. <PRO4> SET +, - Automatic

Timer range Timer period


2 turns
Flat “ms” Approx. 0.5ms, Approx. 1 to 9,999ms +, - Automatic
Type “sec.” Approx. 0.5 sec., Approx. 1 to 32 sec.
Copy action Display Display
Small
“1/10ms” Approx. 0.05ms, Approx. 0.1 to 999.9ms
setting adjustment Display copy +, - adjustment OFF
Hysteresis SET +, -
Spot setting Standard +, - Large +, - Small
SET
Narrow +, - +, -
Beam +, -
+, - +, -
Copy lock setting Copy lock OFF Copy lock ON
Wide SET +, -
Beam Displayed in Incident light
+, - Shift amount
setting percentage intensity (Note 3)
SET +, -
Convergent +, -
Reflective
Type Communication Communication Communication
Retroreflective protocol setting mode emission halt
Notes: 3) Incident light intensity setting depends on the response times.
SET +, -
Type
Response time Incident light intensity
“ ”, “ ”, “ ” Max. 4,000
Chemical / Oil- “ ” Max. 8,000
+, -

resistant “ ”, “ ” Max. 9,999 Only displayed in FX-502□ or FX-505□-C2


Heat- +, - External input
resistant setting (Note 6) SET Only one unit SET Emission OFF +, - Teaching
Saturation correction SET SET SET Correcting
Vacuum-
resistant Automatic
+, -
Automatic
Liquid Leak / <RUN mode> +, -
Limit +
Liquid Detection +, -
In case saturation
correction is NG, +, - <PRO6> (
it is not displayed. +, -
Emission power
setting (Note 4) Copy lock Limit -
SET High emission power +, - Middle emission power +, - Low emission power

Fiber +, -
+, - +, -
Options Notes: 4) In case the response time setting is set to “ ” when the
+, - hysteresis setting is “ ” , the emitting power becomes Display adjustment Logic setting
low sensibility (“ ”) whichever selecting “ ”, “ ” or
“ ”.
+, - +, -
+, -
Timer range
Semi-custom setting ms +, - sec. +, - 1/10ms
Data bank Data bank
fibers SET save +, - load

+, -
All SET Emission OFF +, - Teaching

Teaching lock
Fiber <PRO2> SET setting Lock OFF +, - Lock ON
+, -
Dimensions
SET
Limit +
+, -
Thru-beam +, -
Type +, -
Setting items in Incident light Displayed in Peak /
Retroreflective digital display setting SET intensity percentage +, - bottom value Display adjustment Limit -
Type +, -

Reflective +, - +, - +, -
Type
+, -

Data bank Data bank


Setting of digital
save load
Others display turning SET Turning OFF +, - Turning ON +, -

+, -
+, - Notes: 6) The signal input time from outside is as follows.
Input time
ECO setting SET Eco OFF +, - Eco ON +, - Full 2 point teaching

Amplifiers +, - Limit teaching 20 to under 500ms


Display adjust
+, - +, -
Full auto teaching 600ms or more (sampling during input)
FX-500 Emission OFF, Logic setting
2ms or more (conducted during inputting)
series Time period hold Copy lock
setting (Note 5) SET Hold OFF +, - Hold ON Input pulse of the specified channel number
FX-100 Data bank loading
Data bank saving
(1 pulse: 16 to 300ms).
series However, the pulse cycle is under 500ms.

Notes: 5) In order to clear the value, set the time period holding
function to OFF once. Turning the power OFF can also
clear the value.

INDEX
95

PRECAUTIONS FOR PROPER USE New product


introduction
ion Abstract from “PRO MODE OPERATION MANUAL” Tough
Fiber
y.

key or

Fiber
ve to next Selection
Guide

Model
Choose
by shape/
application
+, - +, -

good
<PRO5> SET Code setting SET Logic operation Between How to read
<PRO7> SET
setting
SET
adjacent amplifier
SET Invalid +, - and Model No.
Blinks Earlier models
3 times
+, -
comparison
+, -
+, -
+, -
table
Display Target setting +, -
good adjustment setting SET (Note 7)
OFF +, - Confirm +, -
xor or

Only displayed in FX-502□ or FX-505□-C2


Blinks +, -
3 times Between external
<When selecting target setting> input Invalid +, - and
Fibers
SET
Display
Target setting SET 0 SET adjustment setting Super
+, -
+, -
+, -
+, - Quality
+, -
Confirm SET Threaded
SET
xor or
Type
Between sensing output 1
Square Head
+, - SET -
and sensing output 2 Invalid +, - and
Type
SET
Incident light Confirm Confirm
intensity
Notes 7) Target setting of display adjust setting depends on the re- +, - +, - Cylindrical
sponse time as table below.
+, - Type
good Response time Target setting +, - xor or
“ ”, “ ”,“ ” From -1,999 to 4,000 Sleeve
“ ” From -1,999 to 8,000 Setting of threshold Setting of threshold
+, -
“ ”, “ ” From -1,999 to 9,999
value tracking SET tracking cycle SET OFF +, - 1 sec. Flat
+, -
Reset setting Automatic Type
y SET SET
ment OFF <RUN mode>
+, -
+, - Small
Blink Blinks 3 times Sensing output
Spot
+, -
setting SET OFF +, - ON
Narrow
Response time Emission power Hysteresis Beam
CUSTOM setting SET setting +, - setting +, - setting
Wide
+, -

+, -
+, - Storage cycle Beam
+, -
setting OFF +, - 1 time Convergent
SET
Interference
Reflective
Type
prevention setting SET Default +, -
Retroreflective
Algorithm setting Type
+, - (Note 12) Limit teaching Auto teaching
Chemical / Oil-
SET +, -
Different frequency setting SET Emission frequency 1 +, - Emission frequency 2
resistant
Notes: 12) In case setting to “ ”, conduct the limit teaching for the Heat-
resistant
+, - +, -
Teaching changed incident light intensity.
Shift direction of the threshold differs depending on the com-
Emission frequency 3 bination of the sensing output status and the sensing output Vacuum-
+, - operation. resistant
Limit +
Window Sensing output status
Sensing output
Shift direction Liquid Leak /
Liquid Detection
operation
comparator mode Rising differential Trailing differential
Sensing output ON Light-ON -
+, - <PRO6> (Note 8) SET Normal mode +, - (Except sensing output 2) +, - mode (Note 9) +, - mode (Note 9)
Sensing output ON Dark-ON +
Limit - Sensing output OFF Light-ON +
+, - +, - <PRO1>
Sensing output OFF Dark-OFF -

+, - Forced OFF Hysteresis Fiber


output mode In case FX-502□ or FX-505□-C2, by mode Options
ic setting pressing down MODE key long time,
sensing output 1 or 2 can be changed
+, - to another. +, -
+, -
Only displayed in Only displayed in
Forced ON
bank output mode
FX-505□-C2 FX-502□ or FX-505□-C2 Semi-custom
+, - +, -
fibers
Answer back output Self-diagnosis
Teaching mode (Note 10) output mode
(Except sensing output 1) (Except sensing output 1)

+, -
<Window comparator mode or Hysteresis mode> Fiber
Limit +
(The following diagram shows in selecting the window comparator mode.) Dimensions
Shift amount setting
SET (Displayed in percentage) SET
Thru-beam
+, - Type
Limit - +, - +, - Retroreflective
SET SET Type
+, - Shift amount setting (Note 11) Reflective
Type
+, - +, -

bank

Notes: 8) : Set the sensing output setting after input / output setting for FX-502□. Others
9) In case using in differential mode, set threshold value 20 or more when the hys-
teresis setting is “ ” and set threshold value 80 or more when the hysteresis
setting is “ ” or “ ”.
10) After external input, the time given until an answer back output is as follows. However, in case
timer of the sensing output 2 is valid, the output time is different from the following table.

2 point teaching
Input time
After 20ms from the input end, the answer back
Amplifiers
Limit teaching output is read out when result of the teaching is “
ng)
Full auto teaching ”. FX-500
Display adjust
After 20ms from the input end, the answer back series
number output is read out.
After 520ms from rising of last input pulse, the an- FX-100
ms. Data bank loading
Data bank saving
swer back output (pulse) of the number of channel in series
the data bank is read out.
11) Incident light intensity depends on the response time as table below.
Response time Incident light intensity
“ ”, “ ”, “ ” Max. 4,000
“ ” Max. 8,000
INDEX
“ ”, “ ” Max. 9,999
96
Refer to p.48 ~ for details of fiber dimensions.
New product DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough
Fiber FX-501(P)  FX-502(P) Amplifier FX-505-C2  FX-505P-C2 Amplifier
62.5 2.461 9.95 Output selection indicator 62.5 2.461 9.95
Output selection indicator 0.392 8.2 0.392
(Yellow) (Note 1) 8.2 2 0.079 (Yellow) 2 0.079
0.323 0.323 MODE key
Digital display (Green / Red)
Fiber
Selection Output 1 operation indicator
Guide Output 1 operation indicator (Orange)
(Orange) (Note 2)
Model Setting switch MODE key Output 2 operation indicator Digital display (Green / Red) Setting switch
Output 2 operation indicator (Orange)
Choose (Orange) (Note 1)
by shape/
application
How to read 27.8 1.094
Model No 27.8 1.094 1.1 0.043
ø4 ø0.157
Communication window 22.7 0.894 22.7 0.894
Earlier models 10 7 0.276 10 Communication window 7 cable 2 m 6.562 ft
comparison Beam- 0.394
table Beam- 0.394 0.276
emitting emitting
part part

32 32 28
Beam-
Beam- 1.260 28 20.8 receiving
1.260 1.102 20.8
10.5
Fibers 1.102 10.5 7 0.276 0.819
receiving 7 0.276 0.819 part 0.413 9.2
0.413 0.362
part 5.7 0.224
Super 5.7 0.224
24 0.945 36.5 1.437
Quality 24 0.945 36.5 1.437 3 3.95
3 3.95 0.118 0.156
75 2.953
Threaded 0.118 0.156 75 2.953 2.8 0.110
Type Suitable for 35 mm 1.378 in width DIN rail (Note 3)
Suitable for 35 mm 1.378 in width DIN rail
Square Head
Type Notes: 1) FX-502(P) only
2) FX-501(P): Operation indicator
Cylindrical
Type 3) FX-501(P): 3-pin, FX-502(P): 4-pin

Sleeve

Flat CN-73-C□  CN-74-C□ Main cable (Optional) CN-71-C□  CN-72-C□ Sub cable (Optional)


Type
Small • Length L • Length L
Spot 50 50
Model No. Length L L 1.969 Model No. Length L L 1.969
Narrow (Note 2) (Note 2)
Beam
CN-73/74-C1 1,000 39.370 CN-71/72-C1 1,000 39.370
Wide
Beam CN-73/74-C2 2,000 78.740 CN-71/72-C2 2,000 78.740
ø3.3 ø0.130 cable ø3.3 ø0.130 cable
Convergent
Reflective CN-73/74-C5 5,000 196.850 CN-71/72-C5 5,000 196.850 10
Type 10
0.394 3 0.394
Retroreflective
Type
(0.551
14
) ( )6
0.236 (0.551
14
) 0.118 6
( )
0.236
Chemical / Oil-
2.54
0.100
(0.114
2.9
) 2.54
0.100 (0.114
2.9
)
resistant
Heat-
resistant
(0.472) 0.413
12 10.5
(0.472) 0.413
12 10.5
(Note 1) (Note 1)
Vacuum- 2.54
resistant 0.100 7 2.54 7
0.2 3 2.65 0.100 0.2 3
2.65 0.008 0.276 0.276
Liquid Leak / 0.118 0.104 0.008 0.118
0.104 10 7.2 10 7.2
Liquid Detection 0.394 0.394 0.283
0.283 13.6
13.6
0.535 0.535
Notes: 1) CN-74-C□ only Notes: 1) CN-72-C□ only
2) CN-73-C□: 3-core 2) CN-71-C□: 1-core
Fiber
Options
MS-DIN-2 Amplifier mounting bracket (Optional) MS-DIN-E End plate (Optional)

21.6 0.850 2.75


Semi-custom 5.2 3.2 0.108
16 0.630
fibers 0.205 0.126

8.5 10
0.335 0.394 M3 (length 18 mm 0.709 in) pan head screws
3.2 5.2 3 60 3
Fiber 0.126 0.205 5 0.118 15 2.362 0.118 5.6 M3 square nut
Dimensions 0.197 0.591 0.220
35
Thru-beam 0.4 2 1.378
Type 0.016 ø1.8 0.079 2 24.7
Retroreflective ø0.071 0.079 0.972
Type 7.5
0.295 4.2 0.165
Reflective t1 32 4
Type t 0.039 1.6
1.260 0.157
2-ø3.2 ø0.126 holes 27 0.063
Suitable for 35 mm 1.378 in width DIN rail
Others 1.063
Material: Polycarbonate
Material: C
 old rolled carbon steel (SPCC)
(Uni-chrome plated)

Amplifiers
FX-500
series
FX-100
series

INDEX
97
98
Digital Fiber Sensor
FX-100 SERIES
New product
introduction
Tough
Fiber

Fiber
Selection
Guide
Taking fiber sensors to the next level
Model
Choose
by shape/
application
How to read Conforming to
Listing
Model No EMC Directive
Earlier models
comparison
table

Fibers
Super
Quality
Threaded
Type
Square Head
Type
Cylindrical
Type
PNP output Timer Interference Light intensity
type available prevention monitor
Sleeve * The FX-100 series has been changed to Panasonic brand from production in and after July 2011.
* Cover opened state is shown.
Flat
Type
Small Automatic Test input
Spot sensitivity setting

Narrow
Beam
Wide
Beam
Convergent
Good dual digital display
Reflective
Type
Retroreflective
The threshold value and incident light intensity can
Type be both confirmed at the same time, bringing good
Chemical / Oil- operability when making changes of each setting.
resistant Threshold value Incident light intensity
Heat-
resistant
Vacuum-
resistant
Liquid Leak / Commercially-available connectors reduce lead time and spare part numbers
Liquid Detection
Compatible with commercially-available connectors, so that
processing costs and lead time required for processing after
Fiber purchase can be greatly reduced. The connection parts same as
Options the DP-100 series digital pressure sensors and the PM-64 series
micro photoelectric sensors can be commonly used. Commercially-available
connector
Semi-custom Commercially-available crimping connectors are used, so that
fibers
the processing costs for connection cables can be greatly
reduced.

Fiber Conventional (cable type) Conventional lead time


Dimensions ● Harness processing by outside order is needed after sensor preparation.
Thru-beam
Type Customer Sensor preparation Sensor installation
Retroreflective Purchase and preqaration of sensor Harness
Type Harness processing by outside order processor Harness processing
Sensor installation
Reflective
Type From now on (built-in connector type) Lead time from now on
Others ● Harness processing can be done by outside order at the
same time of sensor preparation. No need junction connector.
Customer Sensor preparation Sensor installation Reduced
Purchase and preqaration of sensor
Harness processing by outside order Harness Harness processing
Sensor installation processor
Amplifiers
Using cables with connectors Lead time further reduced
FX-500
series ● Harness processing by outside order is not needed.
FX-100 Lead time and spare part numbers can be reduced.
Reduced
series Purchase and preqaration of lead time
sensors and cable with connectors Customer Sensor preparation Sensor installation Reduced
Sensor installation

INDEX
99

Saving-space with a width of 9 mm 0.354 in Improved stability over long terms New product
introduction
Very slim body at only 9 mm 0.354 in. This is much Utilizes “Four-chemical emitting element” for light Tough
thinner than existing fiber sensors. This makes a very emission. The light emission is guaranteed to be stable Fiber
large difference when using many units, even if the over long periods of time.
difference of one unit is small.
Fiber
[Stable sensing comparison] Selection
FX-100 Guide

9 mm Three-chemical Model
0.354 in emitting element
Choose

Light-emitting
by shape/
Incident light intensity application
How to read

amount
Threshold value Long-term
Model No.
stability
Earlier models
comparison
Time table

Simple operation due to clear configuration system Fibers


Super
Continued to use the configuration system of digital pressure sensor DP-100 series, which has received high Quality
popularity since its release. We have separated the settings into three levels: RUN mode, SET mode, and PRO Threaded
mode, making operation simpler and easier. Type
Square Head
Functions used during normal operation Type
RUN mode Cylindrical
Type
• Changing threshold values • Key lock
Sleeve
• Quick settings • Code settings
Flat
Functions used when initializing Type
Simple setting
the sensor and carrying out maintenance Small
Spot
SET mode Narrow
• Teaching • L-ON / D-ON setting Beam
• Timer setting • Emission amount Wide
Beam
• Emission frequency setting Convergent
Reflective
Equipped with a full complement Type
of digital fiber sensor functions Retroreflective
Type
PRO mode Chemical / Oil-
resistant
Special and detailed setting • Shift setting • External input
Heat-
• Reset • GETA resistant
• ECO • Inverting display
Vacuum-
• Threshold value margin • Copy resistant
• Threshold value follow-up cycle Liquid Leak /
Liquid Detection

Quick code input function  RUN mode

Simply imputing the default setting “code (number)” Fiber


Options
will enable sensor settings. Even if the settings are
accidentally changed, imputing the code will restore the
default settings.
Quick setting: Press and simultaneously for 2 sec. Semi-custom
Confirmation can be carried out smoothly via telephone fibers
by simply quoting numbers. This can be of great Code setting: Press and simultaneously for 4 sec.
assistance when dealing with foreign country customers.
Fiber
Dimensions
Quick setting numbers (abstract) Thru-beam
Output Emission amount Type
No Timer
operation setting Retroreflective
None OFF Type
Dark-ON
Reflective
Dark-ON None ON Type

Dark-ON OFF-delay 10 ms OFF Others

Dark-ON OFF-delay 10 ms ON
Light-ON ON-delay 40 ms ON
Light-ON ON-delay 40 ms OFF Amplifiers

ON-delay 10 ms FX-500
Light-ON ON series
Light-ON ON-delay 10 ms OFF FX-100
series

Refer to “Quick setting function” and “Code setting function”


in “PRECAUTIONS FOR PROPER USE” for details.
INDEX
100
100

New product Teaching with ON / OFF keys  SET mode Resolves variation in incident light intensity display
introduction GETA function  PRO mode
Tough Simply press the ON key when an object is present, and
Fiber
OFF when it is not, and teaching is completed. There is Even when performing the same sensing operation,
no need to consider difference between Light-ON and there may be variances in the digital values of the fiber
Dark-ON. amp. There is no problem with the sensor itself, but the
Fiber
Selection
Guide <Setting example> operator may find it troubling.
Thru-beam type / Retroreflective type
Given value can be corrected with the GETA function, so
Model
the apparent variation can be eliminated and the creation
Choose
by shape/
application
of operation manuals can proceed smoothly.
How to read
Model No Variations in the amount of light received
Earlier models
comparison
table Object present ON Object absent OFF

Fibers
Super
Quality Reflective type
Unify at 500 using
Threaded
Type the GETA function
Square Head
Type
Cylindrical
Type

Sleeve
Object present ON Object absent OFF
Flat
Type
Small
Spot
Narrow Example of current incident light intensity display of ‘ ’ is
Beam adjusted to ‘ ’
Wide 4,000
Beam [digits]
Convergent
Because the original
Reflective Teaching even without an object 4,000
Incident light intensity

value is 500, sensor


Type
— Limit teaching function [digits] displays 500 for the
Retroreflective lower limit value
Type Threshold value can be set by performing teaching only and 4,000 for the

Chemical / Oil- when an object is absent (when the incident light amount upper limit value.
resistant is stable). This is useful when there are other objects in
Heat- the background also when defecting a minute objects. 500 1,000
resistant
Teaching can also be carried out using external input.
current value
Vacuum- 0
resistant 500
Not
Liquid Leak / displayed
Liquid Detection 0

Fiber
Options
Threshold value follow-up cycle Emission amount setting
setting function  PRO mode function  SET mode
Semi-custom
fibers This function performs automatic setting to threshold Emission amount can be reduced in order to achieve
value by checking the incident light intensity at desired stable detection when the receiving light level is
intervals in order to follow the changes in the light saturated, such as detection at close range and
Fiber amount resulting from changes in the environment over detection of transparent or minute objects. Previously,
Dimensions long periods (such as dust). Contributes to reduction in the emission amount level was only one, but from
Thru-beam maintenance hours. production in December 2007, four level setting (three
Type
level + auto setting) has become available. This function
Retroreflective * Effective when the output Current value
brings easier settings than before.
Type Incident light
Incident light intensity

operation is set to Dark-ON, intensity when an


Reflective and when using thru-beam type object is absent.
Type
or retroreflective type fibers. 【Light receiving level saturated】 【Stable sensing】
Others
Incident light

Actual digit difference: C


intensity

Threshold value
A
Upper display limit
Actual digit difference: C
4000 Light emitting ,
amount decreased A
B
Amplifiers
Time Saturated digit ,
Incident light

difference: D B
FX-500
intensity

series
FX-100
series

INDEX
101
101

Emission frequency setting mode  SET mode Setting copy function to reduce man-hours New product
and human error  PRO mode introduction
Mutual interference is prevented for max. 3 units for Tough
Fiber
standard type FX-101□ and max. 4 units in case of long By connecting a fiber sensor to the master fiber sensor,
sensing range type FX-102□. the master sensor settings can be copied along with
During setting of interference prevention, emitter and data communications. When the same settings are
output indicator both flash, so it is convenient to confirm input to several units, trouble from setting errors can be Fiber
Selection
which fiber is in the setting process at a glance. Emitter prevented, also changes to the work order will be small Guide

flashes even when an amplifier is not installed close when equipment design is changed. Model
together. Choose
by shape/
* When the emission frequency is changed, a response time is also application
<Wiring to copy settings>
changed. Color of lead wire of attached connector cable How to read
Model No.
Earlier models
Master side (Brown) +V comparison
table
(Black) Output
+ 12 to 24 V DC
(White) External input – ±10 %
(Blue) 0 V
Copy Fibers
Slave side (Brown) +V
Super
(Black) Output Quality
The emitter and output indicator flash Threaded
at the same frequency. (White) External input
Type
(Blue) 0 V Square Head
Type
External input setting mode  PRO mode
Cylindrical
These settings can be copied Type
External input can be selected from emission halt, limit
teaching / full-auto teaching / 2-level teaching, ECO Threshold value, output operation, timer operation, timer
Sleeve
or emission amount test. Threshold value set at each emission amount, shift, external input, threshold value-
teaching is also memorized. storing, ECO inverting digital display, and threshold value Flat
Type
margin
* 2-level teaching, emission amount test and threshold value storing Small
setting are available in amplifiers manufactured after December 2007. Spot
Narrow
Beam
Without mounting bracket
Color of lead wire of attached connector cable

(Brown) +V Wide
Beam
(Black) Output
Selectable either mounting on DIN rail or direct mounting Convergent
Reflective
(White) External input
PLC etc. with through hole. Type
(Blue) 0 V Direct mounting brings stability even on a movable parts or Retroreflective
Type
installation of a single unit.
External input lines are Chemical / Oil-
equipped as standard resistant
Heat-
resistant
Digital display inversion setting  PRO mode
Vacuum-
resistant
The viewing orientation of the digital display can be
Liquid Leak /
inverted in accordance with the setting direction of the Liquid Detection
amplifier.
Previous products
(without inversion function) FX-100 SERIES Fiber
ø3.2 mm 0.126 in mounting holes Options
Can be mounted with M3 screws.
Turn OFF
Semi-custom
fibers
Available from standard type or long
Turn ON
sensing range type
Fiber
Alert function  PRO mode Standard type and long sensing range type are available Dimensions

When the amount light received approaches the which has various response time and sensing range. Thru-beam
Type
threshold value, the display can be made to blink in order The model best meet application needs can be selected.
Retroreflective
to alert the operator. Type
Model No. Type Sensing range Response time
(FT-B8) Reflective
<When using at a shift amount of 20% and a threshold value of 1,000> Type
FX-101 Standard type 400 mm 15.748 in Max. 250 μs
The amount of light received ranges from about 900 to 1,100 Others
when the digital indicator flashes. FX-102 Long sensing range type 1,150 mm 45.276 in Max. 2.5 ms

Range of the digital indicator flashing


(margin: small)
Incident light intensity

Amplifiers
Power consumption saving with
FX-500
1,100 approx.
Threshold value ECO mode ECO series
of 1,000 FX-100
900 approx.
series
When there is no key operations in approximately 20
seconds, digital display turns off and power consumption
can be reduced to 600mW or less (720mW in normal
mode). INDEX

The digital indicator flashes.


102
102

New product ORDER GUIDE


introduction
Tough Amplifiers
Fiber
Accessory
Emitting
Type Appearance Model No. Output
element • CN-14A-C2
Fiber Connector attached
Selection NPN open-collector
Guide FX-101 (Note 2) transistor
cable 2 m 6.562 ft
Model * Only include cable set type
M8 plug-in

NPN open-collector
connector

Choose FX-101-Z (Note 3) transistor


type

by shape/
application
Standard type

PNP open-collector
How to read FX-101P (Note 2)
Model No transistor
Earlier models
M8 plug-in

PNP open-collector
connector

comparison FX-101P-Z (Note 3)


table transistor
type

NPN open-collector
FX-101-CC2
Cable set
(Note 1)

transistor
Fibers PNP open-collector
FX-101P-CC2 collector transistor
Super Red LED
Quality • FC-FX-1 (Protection cover)
NPN open-collector
FX-102 (Note 2) transistor * It have been attached from the
Threaded
Type production at July, 2011.
M8 plug-in

NPN open-collector
connector
Long sensing range type

Square Head FX-102-Z (Note 3) transistor


type

Type
Cylindrical PNP open-collector
Type FX-102P (Note 2) transistor
Sleeve
M8 plug-in

PNP open-collector
connector

FX-102P-Z (Note 3) transistor


type

Flat
Type NPN open-collector
FX-102-CC2
Cable set
(Note 1)

Small transistor
Spot
PNP open-collector
Narrow FX-102P-CC2 transistor
Beam
Wide Notes: 1) The connector attached cable 2 m CN-14A-C2 is supplied with the amplifier.
Beam  ake sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd.
2) M
Convergent (contact: SPHD-001T-P0.5, housing: PAP-04V-S)
Reflective
Type 3) Make sure to use the optional M8 connector attached cable CN-24A-C□.
Retroreflective
Type
Chemical / Oil-
OPTIONS
resistant
Heat- M8 connector attached cable
resistant
Designation Model No. Description • CN-24A-C□
Vacuum-
resistant 31.4 ø4
Liquid Leak / CN-14A-C1 1 m 3.281 ft 1.236 ø0.157
Liquid Detection
Connector CN-14A-C2 (Note) 2 m 6.562 ft
attached cable CN-14A-C3 3 m 9.843 ft ø9 M8 connector
ø0.354 attached cable
CN-14A-C5 5 m 16.404 ft 0.2 mm2 4-core cabtyre cable with connector CN-24A-C□
Fiber on one end
Options CN-14A-R-C1 1 m 3.281 ft Cable outer diameter: ø3.7 mm ø0.146 in
Connector CN-14A-R-C2 2 m 6.562 ft
attached cable Fixing ring
(Flexible type) CN-14A-R-C3 3 m 9.843 ft
Semi-custom
fibers CN-14A-R-C5 5 m 16.404 ft
For M8 plug-in connector type
Amplifier mounting
M8 connector CN-24A-C2 2 m 6.562 ft
The connector on one end bracket
attached cable CN-24A-C5 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in • MS-DIN-4
Fiber
Dimensions Connector CN-14A Set of 10 housings and 40 contacts
Thru-beam Amplifier
Type mounting bracket
MS-DIN-4 Mounting bracket for amplifier
Retroreflective
Type MS-DIN-E When it moves depending on the way it is installed on a DIN rail,
End plates these end plates ensure that all amplifiers are mounted together
Reflective Two pcs. per set in a secure and fully connected manner.
Type
Note: The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□-CC2.
Others
Connector
attached cable
• CN-14A(-R)-C□
Amplifiers Recommended connector
FX-500 Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
series Connector
Note: Contact the manufacturer for details of the recommended products.
FX-100 • CN-14A
series
Contact
Recommended crimping tool
Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)
INDEX Note: Contact the manufacturer for details of the recommended products.
Housing
103
103

SPECIFICATIONS New product


introduction
Tough
Standard type Long sensing range type Fiber
Type
Cable set Cable set
Model No.

NPN output FX-101(-Z) (Note 5) FX-101-CC2 FX-102(-Z) (Note 5) FX-102-CC2 Fiber


Selection
Item PNP output FX-101P(-Z) (Note 5) FX-101P-CC2 FX-102P(-Z) (Note 5) FX-102P-CC2 Guide

Supply voltage 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Model


Choose
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) by shape/
Power consumption application
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
How to read
Model No.
<NPN output type> <PNP output type>
Earlier models
NPN open-collector transistor PNP open-collector transistor comparison
• Maximum sink current: 100 mA • Maximum source current: 100 mA table
Output
• Applied voltage: 30 V DC or less (between output and 0 V) • Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 1.5 V or less (at 100 mA sink current) • Residual voltage: 1.5 V or less (at 100 mA source current)

Output operation Selectable either Light-ON or Dark-ON, at SET mode Fibers


Short-circuit protection Incorporated Super
Quality
<NPN output type> <PNP output type> Threaded
NPN non-contact input PNP non-contact input Type
• Signal condition • Signal condition Square Head
External input High: +8 V to +V DC or Open High: +4 V to +V DC Type
Low: 0 to +2 V DC (Sink current 0.5 to 3 mA)
Cylindrical
(Source current 0.5 mA or less) Low: 0 to +0.6 V DC or Open Type
• Input impedance: 10 kΩ approx. • Input impedance: 10 kΩ approx.
Sleeve
Emission frequency 0: 250 µs or less (factory default setting) Emission frequency 1: 2.5 ms or less (factory default setting)
Flat
Emission frequency 1: 450 µs or less Emission frequency 2: 2.8 ms or less Type
Response time
Emission frequency 2: 500 µs or less Emission frequency 3: 3.2 ms or less
Emission frequency 3: 600 µs or less Emission frequency 4: 5.0 ms or less Small
Spot
Sensitivity setting 2-point teaching / Limit teaching / Full-auto teaching Narrow
Beam
Operation indicator Orange LED (lights up when the output is ON)
Wide
Digital display 4 digits (green) + 4 digits (red) LCD display Beam
Convergent
Fine sensitivity adjustment function Incorporated Reflective
Type
ON-delay / OFF-delay timer, switchable either effective or ineffective Retroreflective
Timer function Type
[Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms]
Chemical / Oil-
Emission amount setting function 3-level + Auto setting (from production in December 2007) resistant

Incorporated Incorporated Heat-


Interference prevention resistant
Emission frequency selection method (Note 2) Emission frequency selection method (Note 2)
function Vacuum-
(Functions at emission frequency 1, 2 or 3) (Functions at emission frequency 1, 2, 3 or 4)
resistant
–10 to +55 °C +14 to +131 °F (If 4 to 7 units are mounted close together: –10 to +50 °C +14 to +122 °F, if 8 to 16 units are mounted close together: Liquid Leak /
Ambient temperature Liquid Detection
Environmental resistance

–10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face
Fiber
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3) Options
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3)
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Semi-custom
Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each fibers
Emitting element (modulated) Red LED (Peak emission wavelength: 643 nm 0.025 mil)
Material Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT
Connecting method Connector (Note 4) Fiber
Dimensions
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm , or more, cable.
2
Thru-beam
Type
Net weight: 15 g approx. Net weight: 15 g approx. Net weight: 15 g approx. Net weight: 15 g approx.
Weight Retroreflective
Gross weight: 35 g approx. Gross weight: 75 g approx. Gross weight: 35 g approx. Gross weight: 75 g approx. Type

FC-FX-1 FC-FX-1 Reflective


Type
FC-FX-1 (Protection cover): 1 pc. (Note 6) FC-FX-1 (Protection cover): 1 pc. (Note 6)
Accessory
(Protection cover): 1 pc. (Note 6) CN-14A-C2 (Protection cover): 1 pc. (Note 6) CN-14A-C2 Others
(Connector attached cable, 2 m 6.562 ft long): 1 pc. (Connector attached cable, 2 m 6.562 ft long): 1 pc.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to
different frequency values. Amplifiers
However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2.
3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. FX-500
series
4) Connector attached cable CN-14A-C2 is not attached to the models that have no “-CC2” at the end of the model Nos.
Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd. FX-100
series
(contact: SPHD-001T-P0.5, housing: PAP-04V-S).
5) Model Nos. having the suffix “-Z” are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□.
6) Protection cover FC-FX-1 has been attached from production in July, 2011.

INDEX
104
104

New product I/O CIRCUIT AND WIRING DIAGRAMS


introduction
Tough
Fiber FX-10□(-Z/-CC2) NPN output type

I/O circuit diagram Terminal arrangement diagram


Fiber Terminal No.
Selection Connector type
Guide
Color code of cable with connector
Model
Choose
(Brown) +V Terminal No. Function
1
by shape/ D
application Load +V
(Black) Output 1
Sensor circuit

How to read Tr 2
Model No +8 V 100 mA max. + 12 to 24 V DC 2 Output
ZD
Earlier models (White) External input – ±10 % 3
comparison 3 External input
table *1 4
(Blue) 0 V 0V
4

Internal circuit Users’ circuit


Fibers
M8 plug-in connector type
Super Symbols … D : Reverse supply polarity protection diode
Quality
ZD: Surge absorption zener diode
Threaded Tr : NPN output transistor Terminal No. Function
Type
Square Head +V
* 1 1
Type 2
Output
Cylindrical Non-voltage contact or NPN open-collector transistor
Type
External input
4
Sleeve or 3
0V
Flat
Type High (+8 V to +V DC, or open): Ineffective
Low [0 to +2 V DC (source current 0.5 mA or less)]: Effective
Small
Spot
Narrow
Beam
FX-10□P(-Z/-CC2) PNP output type
Wide
Beam I/O circuit diagram Terminal arrangement diagram
Convergent
Reflective
Type Terminal No.
Connector type
Retroreflective
Type Color code of cable with connector
Chemical / Oil- (Brown) +V Terminal No. Function
resistant 1
*1
Heat- (White) External input 1 +V
Sensor circuit

resistant 3
+ 12 to 24 V DC 2 Output
Vacuum- ZD
100 mA max.
resistant – ±10 % 3
Tr 2 External input
Liquid Leak / (Black) Output 4
Liquid Detection Load
D (Blue) 0 V 0V
4

Internal circuit Users’ circuit

Fiber M8 plug-in connector type


Options Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor Terminal No. Function
Semi-custom +V
fibers 1
2
* 1 Output
Non-voltage contact or PNP open-collector transistor External input
4
Fiber 3
or 0V
Dimensions
Thru-beam
Type High [ +4 V to +V DC (sink current 0.5 to 3 mA)]: Effective
Retroreflective Low (0 to +0.6 V DC, or open): Ineffective
Type
Reflective
Type

Others

Amplifiers
FX-500
series
FX-100
series

INDEX
105
105

SENSING CHARACTERISTICS (TYPICAL) New product


introduction
Tough
FT-31S Thru-beam type FT-31W Thru-beam type FT-42S Thru-beam type FT-42W Thru-beam type Fiber

Parallel deviation Parallel deviation Parallel deviation Parallel deviation


400 250 1,000 800 Fiber
15.748 9.843 39.370 31.496 Selection
Guide

Model
FX-102 200 FX-102 800 FX-102

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)
300 7.874 31.496 600
11.811 23.622
FX-102 Choose
150 600 by shape/
FX-101 5.906 23.622 application
200 FX-101 400 FX-101
7.874 Fiber 15.748 Fiber How to read
Fiber 100 head 400 FX-101 Fiber head Model No.
head 3.937 ℓ 15.748 head
ℓ Earlier models
ℓ ℓ comparison
100 200
3.937 L 50
L
200 L 7.874
L table
Fiber 1.969 Fiber 7.874 Fiber Fiber
head head head head
0 0 0 0
300 200 100 0 100 200 300 100 50 0 50 100 600 400 200 0 200 400 600 400 200 0 200 400
11.811 7.874 3.937 3.937 7.874 11.811 3.937 1.969 1.969 3.937 23.622 15.748 7.874 7.874 15.748 23.622 15.748 7.874 7.874 15.748
Left Center Right Left Center Right Left Center Right Left Center Right Fibers
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Super
Quality
FT-43 Thru-beam type
FTA235 FT-45X Thru-beam type FT-A11 Thru-beam type Threaded
FTA230 FTA229 Type
Parallel deviation Parallel deviation FTA234
Parallel deviation Square Head
Type
• Horizontal direction • Vertical direction
Cylindrical
1,200 1,000 4,000 4,000 Type
47.244 39.370 157.480 157.480
1,000 FX-102 FX-102 FX-102 FX-102 Sleeve
800
Setting distance L (mm in)

39.370

Setting distance L (mm in)


Setting distance L (mm in)
Setting distance L (mm in)

31.496 3,000 3,000


118.110 118.110 Flat
Type
800
31.496 600 FX-101
Small
23.622 FX-101 FX-101
600 2,000 2,000
23.622
FX-101
Fiber Fiber 78.740 Fiber 78.740 Fiber Spot
head 400 head head head
400 15.748 Narrow
ℓ ℓ
15.748 ℓ 8mm ℓ Beam
L L 1,000 1,000 0.315in L
200
200 39.370 L 39.370 Wide
Beam
Fiber 7.874 Fiber
7.874 head head Fiber Fiber
0 0
head
0
head Convergent
0 400 200 0 200 400 Reflective
1,000 500 0 500 1,000 1,000 500 0 500 1,000 400 200 0 200 400 Type
39.370 19.685 19.685 39.370 39.370 19.685 19.685 39.370 15.748 7.874 7.874 15.748 15.748 7.874 7.874 15.748
Left Center Right Left Center Right Left Center Right Down Center Up Retroreflective
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Type
Chemical / Oil-
resistant
FT-S21W Thru-beam type FT-S31W FTA236
Thru-beam type FD-32G Reflective type FD-32GX FTA237
Reflective type
FTA237 Heat-
resistant
FTA233
Parallel deviation Parallel deviation Sensing field Sensing field
Vacuum-
250 800 250 250 White non-glossy paper resistant
9.843 31.496 9.843 ℓ White non-glossy paper 9.843 200mm 7.874in
L 200mm 7.874in ℓ Liquid Leak /
200 FX-102 FX-102 200 Fiber 200 L Liquid Detection
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

Setting distance L (mm in)

7.874 600 7.874 head 7.874 Fiber


23.622 head
Left Right
150 150 150 FX-102 Left Right
5.906 5.906 FX-102 5.906
400 Fiber
100 FX-101 Fiber
15.748 FX-101
Fiber 100 FX-101 100 FX-101 Options
3.937 head head 3.937 3.937
ℓ ℓ
200
50 L 7.874 L 50 50
1.969 1.969 1.969
Fiber
head
Fiber
head
Semi-custom
0 0 0 0
fibers
100 50 0 50 100 400 200 0 200 400 60 40 20 0 20 40 60 40 20 0 20 40
3.937 1.969 1.969 3.937 15.748 7.874 7.874 15.748 2.362 1.575 0.787 0.787 1.575 2.362 1.575 0.787 0.787 1.575
Left Center Right Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Fiber
Dimensions
FTA231 Thru-beam
FD-41S FTA232 Reflective type FD-41W FDA273
Reflective type Type
FDA272
Retroreflective
Sensing field Sensing field Type
• Horizontal direction • Vertical direction • Horizontal direction • Vertical direction Reflective
Type
150 150 250 250
5.906 5.906 9.843 9.843 Others
200 200
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

FX-102 7.874 7.874


FX-102 FX-102 White
100 White 100 White FX-102 White
non-glossy non-glossy non-glossy
3.937 3.937 150 non-glossy 150 paper
paper paper paper
200mm 200mm
5.906
200mm
5.906 200mm Amplifiers
7.874in 7.874in
FX-101 FX-101 7.874in
7.874in
ℓ ℓ 100 ℓ 100 ℓ FX-500
FX-101 FX-101 3.937 3.937
50
L
50
L L series
1.969 1.969 L
Fiber Fiber 50 Fiber 50
Fiber
head FX-100
head head
1.969 head 1.969 series
Up Up
Left Right Down Left Right Down
0 0 0 0
40 20 0 20 40 40 20 0 20 40 60 40 20 0 20 40 60 60 40 20 0 20 40 60
1.575 0.787 0.787 1.575 1.575 0.787 0.787 1.575 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362
Left Center Right Down Center Up Left Center Right Down Center Up
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) INDEX

FDA269 FDA266
FDA269 FDA266
106
106

New product SENSING CHARACTERISTICS (TYPICAL)


introduction
Tough
Fiber FD-42G Reflective type FD-42GW Reflective type FD-61G Reflective type

Sensing field Sensing field Sensing field


Fiber 250 150 400
Selection 9.843 5.906 15.748
Guide

Model 200 FX-102


Setting distance L (mm in)

Setting distance L (mm in)

Setting distance L (mm in)


7.874 FX-102 300
11.811
Choose White 100 White
by shape/ 150 non-glossy 3.937 FX-102 non-glossy
application 5.906 paper paper
White non-glossy 200
How to read 200mm
FX-101
paper
7.874
200mm
Model No 100 FX-101 7.874in 200mm 7.874in FX-101 7.874in
3.937 ℓ 50 ℓ ℓ
Earlier models
comparison L 1.969 L 100 L
table 50 Fiber Fiber 3.937 Fiber
1.969 head head head

Left Right Left Right Left Right


0 0 0
60 40 20 0 20 40 60 30 20 10 0 10 20 30 80 40 0 40 80
2.362 1.575 0.787 0.787 1.575 2.362 1.181 0.787 0.394 0.394 0.787 1.181 3.150 1.575 1.575 3.150
Fibers Left Center Right Left Center Right Left Center Right
Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Super
Quality
Threaded FD-61W FDA271 Reflective type FD-62 Reflective type
Type FDA274 FDA270
Square Head Sensing field Sensing field
Type
• Horizontal direction • Vertical direction • Horizontal direction • Vertical direction
Cylindrical
Type 250 250 500 500
9.843 9.843 19.685 19.685
Sleeve
200 200 400 400
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

7.874 7.874 15.748 15.748


Flat FX-102 White FX-102 White
Type
White FX-102 White
non-glossy FX-102 non-glossy non-glossy non-glossy
150 150 paper 300 paper
300 paper
paper
Small 5.906 5.906 200mm 11.811
200mm
11.811
200mm
Spot
200mm
FX-101 7.874in FX-101 7.874in 7.874in FX-101 7.874in
100 100 ℓ 200 FX-101 200
ℓ ℓ ℓ
Narrow 3.937 3.937 7.874 7.874
Beam L L L L
Fiber
Wide 50 Fiber 50 100 Fiber 100 Fiber
head head head head
Beam 1.969 1.969
Up
3.937 3.937
Up
Convergent Left Right Down Left Right Down
Reflective 0 0 0 0
Type 60 40 20 0 20 40 60 60 40 20 0 20 40 60 150 100 50 0 50 100 150 150 100 50 0 50 100 150
2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 5.906 3.937 1.969 1.969 3.937 5.906 5.906 3.937 1.969 1.969 3.937 5.906
Retroreflective Left Center Right Down Center Up Left Center Right Down Center Up
Type Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in) Operating point ℓ (mm in)
Chemical / Oil-
resistant
FD-64X Reflective type FD-S32W Reflective type
Heat-
resistant FDA265 FDA265 FDA268 FDA268
Sensing field Sensing field
Vacuum-
resistant • Horizontal direction • Vertical direction • Horizontal direction • Vertical direction
Liquid Leak / 250 250 250 250
Liquid Detection 9.843 9.843 9.843 9.843 White non-glossy paper 200mm 7.874in

200 200 200 200 L
Setting distance L (mm in)
Setting distance L (mm in)

Setting distance L (mm in)


Setting distance L (mm in)

7.874 7.874 7.874 7.874 Fiber


White head
FX-102
Fiber 150 FX-102 150 FX-102 150 FX-102 non-glossy
paper
150 Up
Options 5.906 White non-glossy
paper
5.906 White non-glossy
paper
5.906
200mm
5.906 Down

FX-101 200mm 7.874in FX-101 200mm 7.874in FX-101 7.874in FX-101


100 ℓ 100 ℓ 100 ℓ 100
3.937 3.937 3.937 3.937
L L L
Semi-custom 50 Fiber
head
50 Fiber
head
50 Fiber
head
50
fibers 1.969 1.969
Up
1.969 1.969
Left Right Down Left Right
0 0 0 0
60 40 20 0 20 40 60 60 40 20 0 20 40 60 60 40 20 0 20 40 60 60 40 20 0 20 40 60
2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362 2.362 1.575 0.787 0.787 1.575 2.362
Left Center Right Left Center Right Down Center Up
Fiber Operating point ℓ (mm in) Operating point ℓ (mm in)
Left Center Right
Operating point ℓ (mm in)
Dimensions Operating point ℓ (mm in)

Thru-beam
Type FD-S33GW FDA276
Reflective type
FDA276 FDA267 FDA267
Retroreflective
Type Sensing field
Reflective 150
Type 5.906

Others
Setting distance L (mm in)

100 FX-102
3.937
White non-glossy
paper
Amplifiers FX-101 200mm 7.874in

50
FX-500 1.969 L
series Fiber
head
FX-100
series Left Right
0
30 20 10 0 10 20 30
1.181 0.787 0.394 0.394 0.787 1.181
Left Center Right
Operating point ℓ (mm in)
INDEX

FDA275
107
107
Refer to the “Operation Guide” on our website for details pertaining to
PRECAUTIONS FOR PROPER USE operating instructions for the amplifier. New product
introduction
Tough
Wiring Fiber
• Never use this product as a sensing device
for personnel protection. • Make sure that the power supply is OFF while adding or
• In case of using sensing devices for removing the amplifiers. Fiber
Selection
personnel protection, use products which • Note that if a voltage exceeding the reted range is applied, Guide
meet laws and standards, such as OSHA,
or if an AC power supply is directly connected, the product Model
ANSI or IEC etc., for personnel protection
applicable in each region or country. may get burnt or damaged. Choose
by shape/
application
• Note that short-circuit of the load or wrong wiring may burn
How to read
or damage the product. Model No.
Using in combination with the FX-300 / FX-410 series • Do not run the wires together with high-voltage lines or Earlier models
comparison
table
• The FX-100 series does not use the horizontal power lines, or put them in the same raceway. This can
connectors that are used with the FX-300 / FX-410 cause malfunction due to induction.
series. Please note that horizontal connection cannot be • Verify that the supply voltage variation is within the rating.
performed using a connector attached cable. In addition, • If power is supplied from a commercial switching regulator, Fibers
the optical communication function is not equipped on ensure that the frame ground (F.G.) terminal of the power Super
the FX-100 series, so it is unable to perform interference Quality
supply is connected to an actual ground.
prevention for use with the FX-300 / FX-410 series. Threaded
• In case noise generating equipment (switching regulator, Type
If using the FX-100 series together with the FX-300 / Square Head
inverter motor, etc.) is used in the vicinity of this product,
FX-410 series side-by-side, please set the same models Type
connect the frame ground (F.G.) terminal of the equipment Cylindrical
together in groups.
to an actual ground. Type

Mounting • Make sure to use the quick-connection cable (optional) for Sleeve
the connection of the controller.  Flat
<When using a DIN rail>
Extension up to total 100 m 328.084 ft is possible with 0.3 Type
How to mount the amplifier mm2 or more, cable. However, in order to reduce noise, Small
Spot
make the wiring as short as possible.
Fit the rear part of the mounting Narrow
Beam
section of the amplifier on a 35 mm
1.378 in width DIN rail. Wide
Part description Beam
Press down the rear part of the ON key / OFF key / Convergent
Reflective
mounting section of the unit on the 2
Operation indicator
Setting value UP key Setting value DOWN key Type
1
35 mm 1.378 in width DIN rail and (Orange) MODE key Retroreflective
Type
fit the front part of the mounting 35 mm 1.378 in width DIN rail
Chemical / Oil-
section to the DIN rail. resistant

How to remove the amplifier Digital display (Green) Digital display (Red) Heat-
(Threshold value) (Incident light intensity) resistant

Push the amplifier forward. 1 Vacuum-


2 resistant
Lift up the front part of the Setting mode Liquid Leak /
amplifier to remove it. • Setting mode appears after the MODE key is pressed for
Liquid Detection

2 sec. in RUN mode.


Note: Take care that if the front part is lifted without pushing the amplifier
forward, the hook on the rear portion of the mounting section is likely Setting item Factory setting Description Fiber
to break. Options
Teaching Threshold value can be set in 2-point teaching,
mode limit teaching, or full-auto teaching.
<When using screws with washers>
Semi-custom
• Use M3 screws with washers Output fibers
for mounting. The tightening operation Light-ON or Dark-ON can be set.
[Dark-ON]
torque should be 0.5 N·m or setting
less.
Fiber
Timer Dimensions
Without timer, ON delay timer, or OFF delay
operation
[Without timer] timer can be set. Thru-beam
setting
Type

When setting ON delay timer or OFF delay Retroreflective


Type
M3 screw Timer [ON-delay timer: 10 ms] timer in the timer operation setting mode, timer
with washer delays delays can be set. Reflective
Type
setting • When timer is not set, this mode is not
[OFF-delay timer: 10 ms] displayed.
Others

Emission
In case incident light intensity is saturated,
amount
* [Level 3] emission amount can be reduced.
setting
Amplifiers
FX-101□
When using the fiber heads in parallel, FX-500
series
0 (Response time: interference can be prevented by setting
Emission 250 µs or less) FX-100
different emission frequency. However, when
frequency FX-102□ series
emission frequency 0 is set, interference
setting
cannot be prevented. Response time
1 (Response time: corresponds to emission frequency.
2.5 ms or less)

* Indicated as“ ”before production in November 2007. INDEX


108
108
Refer to the “Operation Guide” on our website for details pertaining to
New product PRECAUTIONS FOR PROPER USE operating instructions for the amplifier.
introduction
Tough PRO mode Setting copy function
Fiber
• PRO mode appears after the MODE key is pressed for 4 • This can copy the settings of the master side amplifier to
sec. in RUN mode. the slave side amplifier.
Fiber Setting item Factory setting Description
Selection
Guide
• Be sure to use the setting copy function between the
Shift amount can be selected from 0 to 80 % in identical models (Between FX-101□ models or FX-102□
Model Shift the limit teaching. Select 0 % when it is desired
setting
models).
Choose [Shift amount 15 %] to set the present incident light intensity as a
by shape/ threshold value. This function cannot be used between different
application
External input can be selected from emission models.
How to read
Model No halt, limit teaching [+], limit teaching [-], full-auto • Only one sensor can be connected on slave side with a
Earlier models teaching, ECO (Note 1), 2-point teaching or master side sensor for the setting copy function.
comparison emission amount test. When setting the incident
table
External light intensity test “ ”, output turns ON / • Threshold value, output operation setting, timer
input OFF every 100ms when the rate of incident operation setting, timer setting, light-emitting amount
setting [Emission halt] light intensity and threshold value is less than setting, shift setting, external input setting, threshold
half of the set shift amount (for example, when
Fibers the rate of incident light intensity and threshold
value margin setting, ECO setting, digital display
value is within ±10 % for 20 % of shift amount) inversion setting, and threshold value margin setting
Super at external input. can be copied.
Quality
Threaded Threshold value set at the limit teaching,
Type Threshold full-auto teaching or 2-point teaching by <Setting procedures>
value-storing external input is stored. When selecting
Square Head
setting mode Auto in the emission amount setting Set the setting copy mode of the master side amplifier to
Type [OFF]
(Note 2) mode, the set emission amount level is “Copy sending ON”, and press the MODE key so that
Cylindrical also stored. “ ” is shown on the digital display and the
Type
Threshold When incident light intensity exceeds threshold sensor is in copy ready state. For the setting method,
Sleeve value value, this mode can change the threshold value refer to “Operation guide”.
follow-up with each set cycle depending on variations of the
Flat
cycle incident light intensity. The follow-up shift amount Turn off the master side amplifier.
Type [OFF]
setting is same as the one set in the shift setting mode. Connect the master side amplifier with the slave side
Small (Note 3) However, the threshold value is not stored.
Spot amplifier as shown below.
Variations can be reduced by correcting the
Narrow Color code of cable with connector
Beam present incident light intensity in each amplifier
GETA to a target value. Target value to offset incident Master side amplifier (Brown) +V
Wide function light intensity can be selected from 0 to 2,000
Beam (Black) Input
setting [OFF] by 100 unit each. For example, if the target + 12 to 24V DC
Convergent
Reflective (Note 4, 5) value is set to 2,000 when the incident light (White) External input – ±10 %
Type intensity is 1,500, the incident light intensity
(Blue) 0 V
Retroreflective becomes 2,000.
Type
It is possible to light up / turn off the digital Slave side amplifier (Brown) +V
Chemical / Oil- display. When ECO setting mode is ON, the
resistant ECO (Black) Input
display turns off in 20 sec. approx. in RUN
setting [OFF] (White) External input
Heat- mode. To light up the display again, press any
resistant key for 2 sec. or more. (Blue) 0 V
Vacuum- Digital display
resistant
inversion Digital display can be inverted. Turn on the master side amplifier and the slave side
Liquid Leak / setting [OFF]
Liquid Detection amplifier at the same time. (Note)
Margin for threshold value to the present “ ” is shown on the green digital display of the master
incident light intensity can be checked. When
there is no margin, it is possible to make the side amplifier and 4-digit code is shown on the red
Fiber digital display blink. digital display of it, then the copying starts. During copy
Options : Set to “OFF”: does not function. communication, “ ” is shown on the green digital
Threshold : Green blinks. display of the slave side amplifier, and the ongoing copy
value : Red blinks.
margin : Red and green blink. communication indicator (“ ”→“ ”→“ ”→
[OFF]
Semi-custom setting : When conducting limit teaching or 2-point “ ”→“ ”→“ ”→“ ”→“ ”) is displayed on
fibers teaching by external input, in case the rate of reference the red digital display.
incident light intensity and threshold value after teaching When the copying is completed, “ ” is shown on the
is 200% or more, or in case it is less than half of the shift
green digital display of the slave side amplifier, while the
amount, output turns ON / OFF every 100 ms. (Note 6)
Fiber 4-digit code (the same code as the master side amplifier)
Dimensions The settings of the master side amplifier can is shown on the red digital display of it.
Thru-beam Setting
be copied to the slave side amplifier. Turn off the power of the master side amplifier and the
Type copy [NO]
For details, refer to “Setting copy function”.
Retroreflective slave side amplifier and disconnect the wire.
Type Reset Returns to default settings (factory settings.)
[NO] * If copying the settings to another amplifier repeatedly, follow the steps
Reflective to .
Type Notes: 1) When ECO is selected at the external input setting mode, key
operation on the main body is invalid during external input. Note: Take care that if the power is not turned on at the same time, the
Others 2) This mode is not indicated unless any of “ ”, “ ”, setting contents may not be copied.
“ ” or “ ” is set at the external input setting mode.
(Incorporated from production in December 2007.)
3) If the incident light intensity becomes “300” or less, the follow-up <To cancel the setting copy mode of the master side amplifier>
operation stops. In that condition, threshold value [digital display W
 hile the slave side amplifier is disconnected, turn on
Amplifiers (green)] blinks. This function can be used when thru-beam type or the power of the master side amplifier.
retroreflective type fiber is applied to this product. If reflective type fiber
FX-500 Press the MODE key for 2 sec. approx.
series is applied, the function cannot be used depending on use conditions.
FX-100 4) If MODE key is pressed in RUN mode when GETA function is
series used, the incident light intensity before setting GETA function is
displayed on the red digital display for 2 sec. approx.
5) When GETA function is used in saturation of incident light intensity
(4,000 or more,) “ ” is indicated on the red digital display.
INDEX Correction value is up to 4,000.
6) This mode does not operate unless any of “ ”, “ ” or
“ ” is set at the external input setting mode.
(Incorporated from production in December 2007.)
109
109
Refer to the “Operation Guide” on our website for details pertaining to
PRECAUTIONS FOR PROPER USE operating instructions for the amplifier. New product
introduction
Others Code setting function Tough
Fiber
• Our products have been developed / produced for • The code setting function makes it possible to set the
industrial use only. output operation, timer operation, amount of light emitted,
• Do not use during the initial transient time (0.5 sec.) after frequency of light emitted, ECO setting, external input, Fiber
the power supply is switched on. and amount of shift by selecting a code of one’s choice. Selection
Guide
• Take care that the product is not directly exposed • While in the RUN Mode, pressing and holding both Model
to fluorescent lamp from a rapid-starter lamp, a high the ON key ( ) and OFF key ( ) simultaneously for 4
Choose
frequency lighting device or sunlight etc., as it may affect seconds will switch to the code setting function. by shape/
application
the sensing performance. How to read
<Code table> Model No.
• This product is suitable for indoor use only.
Earlier models
• Avoid dust, dirt, and steam. comparison
table
• Take care that the product does not come in contact with
oil, grease, organic solvents, such as thinner, etc., strong
acid or alkaline. 1st digit 2nd digit 3rd digit 4th digit
• This product cannot be used in an environment Fibers
Emission Emission
containing inflammable or explosive gases.

Code
frequency Super
• Never disassemble or modify this product. Output Timer amount External Shift Quality
ECO
operation (Note 1) setting input (Note 1) Threaded
• EEPROM is adopted to this product. It is not possible to (Note 2) FX-101□ FX-102□ Type
conduct teaching 100 thousand times or more, because Square Head
of the EEPROM’s lifetime. Emission
Type
non 0 1 5% Cylindrical
halt
Quick setting function Type

• The quick setting function makes it possible to set Limit Sleeve


ond 10 ms 1 2 10 %
the content of the SET Mode (output operation, timer teaching [+]
Flat
Level 3
operation, amount of light emitted, and frequency of light (OFF) Type
emitted) simply by selecting a setting number. D-ON ond 40 ms 2 3 OFF Limit 15 % Small
teaching [-] Spot
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 2 Narrow
Beam
seconds will switch to the quick setting function. Full-auto
ofd 10 ms 3 4 20 % Wide
teaching
Beam
<Table of quick setting numbers> Convergent
Reflective
No. Output operation Timer Emission amount setting (Note) ofd 40 ms 0 1 ECO 25 % Type
Retroreflective
D-ON non Level 3 (OFF) Type
D-ON non Level 2 (ON) Emission Chemical / Oil-
non 1 2 30 %
resistant
halt
D-ON ofd 10 ms Level 3 (OFF) Level 2
Heat-
D-ON ofd 10 ms Level 2 (ON) (ON) resistant
Limit
D-ON ofd 40 ms Level 3 (OFF) ond 10 ms 2 3 35 % Vacuum-
teaching [+]
resistant
D-ON ofd 40 ms Level 2 (ON)
Liquid Leak /
D-ON ond 10 ms Level 3 (OFF) Limit Liquid Detection
L-ON ond 40 ms 3 4 ON 40 %
teaching [-]
D-ON ond 10 ms Level 2 (ON)
D-ON ond 40 ms Level 3 (OFF)
Full-auto
D-ON ond 40 ms Level 2 (ON) ofd 10 ms 0 1 45 % Fiber
teaching
Options
L-ON ond 40 ms Level 2 (ON)
L-ON ond 40 ms Level 3 (OFF) ofd 40 ms 1 2 ECO 50 %
L-ON ond 10 ms Level 2 (ON)
Level 1 Semi-custom
L-ON ond 10 ms Level 3 (OFF) 2-point fibers
L-ON ofd 40 ms Level 2 (ON) 2 3
teaching
L-ON ofd 40 ms Level 3 (OFF) OFF
L-ON ofd 10 ms Level 2 (ON) Incident light Fiber
3 4
intensity test Dimensions
L-ON ofd 10 ms Level 3 (OFF)
Thru-beam
L-ON non Level 2 (ON) 2-point Type
L-ON non Level 3 (OFF) 0 1 Retroreflective
teaching
Type
Note: Until production in November 2007, OFF or ON was selectable. The ON
Reflective
emission amount of Level 2 (ON) is about 40% of that of Level 3 Incident light Type
1 2
(OFF). intensity test
Auto Others
Difference between previous model and upgraded one
2 3
• For upgraded ones (production in and after December
2007), “P” is marked near the beam-emitting inlet.
Previous ones have no marking. Appearance and Amplifiers
3 4
functions have been changed. FX-500
series
<After upgrade> <Previous> Notes: 1) When the present setting is out of the code setting range, “ ” is shown.
When “ ” is selected, the set content of the digit is not changed. FX-100
series
2) Until production in November 2007, OFF or ON was selectable.
The emission amount of Level 2 is about 40% of that of Level 3.
“P” indication The emission amount of Level 1 is about 20% of that of Level 3.
3) The factory setting is “ ”.
INDEX
Beam-emitting inlet
110
110
Refer to p.48~ for details of fiber dimensions.
New product DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website.
introduction
Tough
Fiber
FX-101□   FX-102□ Amplifier FX-101(P)-Z  FX-102(P)-Z Amplifier

6 0.236 6 0.236 10.85


Fiber 48 1.890 6 0.236 6 0.236 0.427
Selection 48 1.890
30 1.181
Guide 0.8 13.2 20 2.7 0.7 30 1.181
0.031 0.787 0.106 0.028 0.8 13.2 20 2.7
0.520
0.031 0.520 0.787 0.106
Model
0.7 0.028
Choose 4.1 OFF key / Setting value DOWN key
by shape/ 4.1 OFF key / Setting value DOWN key
application Operation indicator (Orange) 0.161 ON key / Setting value UP key Operation indicator (Orange) 0.161 ON key / Setting value UP key
How to read Digital display (Green, Red) MODE key
Digital display (Green, Red) MODE key
Model No
Earlier models
comparison
table

0.75 0.030 0.75 0.030

Fibers
66.2 66.2 1
9 2 0.079 9 2.606
Super 2.606 0.354 0.039
0.354
Quality
6 0.236
6 0.236 ø6.5
Threaded 2 1.1 ø0.256
Type 1.1 0.043 0.8
0.043 0.8 0.079 0.031
0.031 7 10 30
Square Head 7 10 30 0.276 4 0.157 3 0.118 0.3941.181
0.276 4 0.157 3 0.118 0.394 1.181
Type 10
10 8.1 0.394
Cylindrical 0.394 0.319 ø3.2
Type ø3.2 ø0.126 3.2 8.1
ø0.126 3.2 6.5 2 0.126 0.319
50 1.969
6.5 2 0.126 0.256 0.079
Sleeve 0.256 50 1.969 0.079 14.5 35 1.378
14.5 35 1.378 0.571
65.5 2.579
Flat 0.571
65.5 2.579 Suitable for 35 mm 1.378 in width DIN rail
Type Suitable for 35 mm 1.378 in width DIN rail
Small Note: The protection cover has been attached from the production at July, 2011. Note: The protection cover has been attached from the production at July, 2011.
Spot
Narrow
Beam
MS-DIN-4 Amplifier mounting bracket (Optional) Previous dimensions (production before November 2007)
Wide
Beam 47 1.850 6 6
ø7.2 mm ø0.283 in ø3.2 ø0.126 3.2 7.2 mm 0.283 in 0.236 0.236
Convergent spot facing, 4 0.157 deep 29 1.142
Reflective 0.126 spot facing, 4 0.157 deep 0.8 12.2 20 0.787 2.7 0.7
Type 0.031 0.480 0.106 0.028
Retroreflective
Type
4.1 OFF key / Setting value DOWN key
Chemical / Oil- 1
0.039 Operation indicator (Orange) 0.161 ON key / Setting value UP key
resistant 9.25 15 Digital display (Green, Red) MODE key
0.364 0.591 6.2 mm 0.244 in
Heat-
resistant ø6.2 mm ø0.244 in spot facing, 3 0.118 deep 1
9
spot facing, 3 0.118 deep 9 0.354 0.039
Vacuum- ø3.2 ø0.126 3.2
0.354
resistant 0.126
1.1 0.8
Liquid Leak / 11.5 0.043 0.031
Liquid Detection 0.453 10 30
7 0.276 4
0.157 0.394 1.181
4 1 10 0.394 8.1
0.157 0.039 0.319
5 24.5 ø3.2
ø0.126 3 3.2
Fiber 0.197 0.965
0.118 2 0.126
Options 35 5.5 0.217 0.079
1.378 50 1.969
Material: PBT 13.5 35 1.378
0.531
64.5 2.539
Suitable for 35 mm 1.378 in width DIN rail

Semi-custom
fibers
MS-DIN-E End plate (Optional) CN-14A-C□   CN-14A-R-C□ Connector attached cable (Optional)
CN-14A-C2 is attached FX-101(P)-CC2 / FX-102(P)-CC2
Fiber L
M3 (Iength 18 mm 0.709 in) pan head screws 35 50
Dimensions 2.75 0.108
8
(1.378 ) (1.969)
60 ( )
Thru-beam
Type 0.118
3
15
2.362 3 0.118
M3 square nut
0.315 (0.3158 )
5.6
0.591 0.220
Retroreflective
Type ø3.7 ø0.146 cable
24.7
Reflective 0.972 • Length L
Type

Others
Model No. Length L
1.6 32 4
0.063 1.260 0.157 CN-14A(-R)-C1 1,000 39.370
Suitable for 35 mm 1.378 in width DIN rail
CN-14A(-R)-C2 2,000 78.740
Material: Polycarbonate CN-14A(-R)-C3 3,000 118.110
Amplifiers CN-14A(-R)-C5 5,000 196.850
FX-500
series
FX-100
series

INDEX
111
112
112

New product INDEX


introduction

C FD-E13
Tough p.17/p.19/p.39/
Fiber Cylindrical / Sleeve Fiber
FD-E23 p.58/p.88
CN-14A FX-100 Connector p.102 Threaded / p.13/p.23/p.39/
FD-EG30
Fiber CN-14A-C1 p.102/p.110 Small Spot Type Fiber p.58/p.88
Selection
Guide p.102/p.103/ p.19/p.39/p.59/
CN-14A-C2 FX-100 FD-EG30S Sleeve Fiber
Model p.110 p.88
Connector Attached Cable
Choose CN-14A-C3 Threaded / p.13/p.23/p.39/
by shape/ FD-EG31
application CN-14A-C5 Small Spot Type Fiber p.59/p.88
How to read CN-14A-R-C1 FD-F4
Model No p.102/p.110
Earlier models CN-14A-R-C2 FX-100 Connector FD-F41
comparison
table CN-14A-R-C3 Attached Cable (Flexible) FD-F41Y Liquid Leak /
p.35/p.39/p.59
CN-14A-R-C5 FD-F71 Liquid Detection Fiber
CN-71-C1 FD-F8Y
Fibers CN-71-C2 FD-FA93
Super
CN-71-C5 FD-H13-FM2
Quality CN-72-C1 FD-H18-L31
p.31/p.40/p.60/
Threaded CN-72-C2 FD-H20-21
Type p.88
Square Head
CN-72-C5 FX-500 FD-H20-M1 Heat-resistant Fiber
p.74/p.96
Type CN-73-C1 Quick-connection Cable FD-H25-L43
Cylindrical CN-73-C2 p.31/p.40/p.60/
Type FD-H25-L45
CN-73-C5 p.89
Sleeve
CN-74-C1 FD-H30-KZ1V p.33/p.44
Vacuum-resistant Fiber
Flat CN-74-C2 FD-H30-KZ1V-S p.32/p.40/p.61
Type
CN-74-C5 p.31/p.40/p.61/
Small FD-H30-L32 Heat-resistant Fiber
Spot p.89
Narrow FD-H30-L32V p.33/p.44
F
Beam
Vacuum-resistant Fiber p.32/p.40/p.61/
Wide FD-H30-L32V-S
Beam p.89
Convergent
Reflective FB-1 Fiber Bender p.18/p.45/p.66 FD-H35-20S
Type p.31/p.40/p.61/
FD-H35-M2 Heat-resistant Fiber
Retroreflective FC-FX-1 FX-100 Protection Cover p.102/p.103 p.89
Type FD-H35-M2S6
p.11/p.39/p.56/
Chemical / Oil- FD-30 Super Quality Fiber FD-HF40Y Liquid Leak / Liquid Detection Fiber p.35/p.40/p.61
resistant p.85
FD-L10
Heat- FD-31 p.13/p.39/p.56/
resistant Threaded Type Fiber FD-L11 p.26/p.40/p.62/
FD-31W p.85
Vacuum- FD-L12W p.89
resistant p.13/p.23/p.39/
Liquid Leak /
FD-32G FD-L20H
Threaded / p.56/p.85/p.105
Liquid Detection FD-L21 p.26/p.40/p.62/
Small Spot Type Fiber p.13/p.32/p.39/
FD-32GX FD-L21W Convergent Reflective Type p.90
p.56/p.86/p.105
FD-L22A Fiber
p.11/p.39/p.56/
Fiber FD-40 Super Quality Fiber FD-L23 p.26/p.40/p.62/
Options p.86
FD-L30A p.90
p.13/p.39/p.56/
FD-41 Threaded Type Fiber FD-L31A
p.86
p.26/p.40/p.63/
Semi-custom p.19/p.39/p.56/ FD-L32H
fibers FD-41S p.90
p.86/p.105
Sleeve Fiber FD-R31G
p.19/p.39/p.56/
FD-41SW FD-R32EG Square Head / p.15/p.23/p.40/
p.86
Fiber FD-R33EG Small Spot Type Fiber p.63
Dimensions p.13/p.39/p.56/
FD-41W Threaded Type Fiber FD-R34EG
Thru-beam p.86/p.105
Type FD-R41 Square Head type Fiber p.15/p.40/p.63
Retroreflective
FD-42G Threaded / p.13/p.23/p.39/
p.13/p.40/p.63/
Type FD-42GW Small Spot Type Fiber p.57/p.86/p.106 FD-R60 Threaded Type Fiber
p.90
Reflective p.11/p.39/p.57/
Type FD-60 Super Quality Fiber Square Head / Chemical / p.15/p.29/p.40/
p.86 FD-R61Y
Others Oil-resistant Fiber p.91
p.13/p.39/p.57/
FD-61 p.17/p.40/p.63/
p.87 FD-S21 Cylindrical Fiber
Threaded Type Fiber p.91
p.13/p.39/p.57/
FD-61G p.11/p.40/p.64/
Amplifiers p.87/p.106 FD-S30 Super Quality Fiber
p.91
p.19/p.39/p.57/
FX-500 FD-61S Sleeve Fiber FD-S31 p.17/p.40/p.64/
series p.87
FD-S32 p.91
FX-100 FD-61W p.13/p.39/p.57/ Cylindrical Fiber
series FD-S32W p.17/p.41/p.64/
FD-62 p.87/p.106
Threaded Type Fiber FD-S33GW p.91/p.106
p.13/p.39/p.58/
FD-64X Chemical / Oil-resistant p.29/p.41/p.64/
p.87/p.106 FD-S60Y
INDEX Fiber p.91
FD-A16 p.25/p.39/p.58/
Wide Beam Fiber
FD-AL11 p.87
113
113

INDEX New product


introduction
FD-V30 p.19/p.41/p.64/ p.30/p.36/p.50/ Tough
FT-H13-FM2 Fiber
FD-V30W p.92 p.80
Sleeve Fiber
p.19/p.41/p.65/ FT-H20-J20 p.31/p.44
FD-V50
p.92 p.30/p.36/p.50/ Fiber
FT-H20-J20-S Selection
p.21/p.41/p.65/ p.80 Guide
FD-Z20HBW
p.92 FT-H20-J30 p.31/p.44 Model
FD-Z20W Flat Type Fiber p.30/p.36/p.50/ Choose
p.21/p.41/p.65/ FT-H20-J30-S by shape/
FD-Z40HBW p.80 application
p.92
FD-Z40W FT-H20-J50 Heat-resistant Fiber p.31/p.44 How to read
Model No.
p.24/p.41/p.65/ FT-H20-J50-S p.30/p.36/p.50/ Earlier models
FD-Z50HW Narrow Beam Fiber comparison
p.92 FT-H20-M1 p.80 table
FDP-1000 FT-H20-VJ50 p.31/p.44
FDP-1500 p.30/p.36/p.50/
FT-H20-VJ50-S
FDP-500 Protective Tube p.80 Fibers
p.45/p.67
FDP-N1000 (For Reflective Type Fiber) FT-H20-VJ80 p.31/p.44
Super
FDP-N1500 FT-H20-VJ80-S p.30/p.36/p.50/ Quality
FDP-N500 FT-H20W-M1 p.80 Threaded
Type
FR-KZ22E p.24/p.27/p.38/ FT-H30-M1V p.33/p.44
Square Head
FR-KZ50E p.55/p.84 Vacuum-resistant Fiber p.32/p.36/p.50/ Type
FT-H30-M1V-S
Narrow Beam / p.24/p.27/p.38/ p.80 Cylindrical
FR-KZ50H Type
Retroreflective Type Fiber p.55/p.85 FT-H35-M2 p.30/p.36/p.50/
Heat-resistant Fiber Sleeve
p.24/p.27/p.38/ FT-H35-M2S6 p.81
FR-Z50HW
p.55/p.85 Chemical / Oil-resistant p.29/p.36/p.50/ Flat
FT-HL80Y Type
p.12/p.36/p.48/ Fiber p.81
FT-140 Threaded Type Fiber Small
p.79 Spot
FT-J8 Fiber for Atmospheric Side p.33/p.44/p.66
Narrow
p.11/p.36/p.48/
FT-30 Super Quality Fiber Beam
p.79 FT-KS40 Wide
p.12/p.36/p.48/ FT-KV26 p.24/p.36/p.51/ Beam
FT-31 Threaded Type Fiber Narrow Beam Fiber Convergent
p.79 FT-KV40 p.81 Reflective
Type
p.19/p.36/p.48/ FT-KV40W
FT-31S Sleeve Fiber Retroreflective
p.79/p.105 Chemical / Oil-resistant p.29/p.36/p.51/ Type
FT-L80Y
p.12/p.36/p.48/ Fiber p.81 Chemical / Oil-
FT-31W Threaded Type Fiber resistant
p.79/p.105 FT-R31 Square Head Type Fiber p.15/p.36/p.51
Heat-
p.11/p.36/p.48/ p.12/p.36/p.51/ resistant
FT-40 Super Quality Fiber FT-R40 Threaded Type Fiber
p.79 p.81 Vacuum-
resistant
p.12/p.31/p.36/ FT-R41W p.14/p.15/p.36/
FT-42 Threaded Type Fiber Liquid Leak /
p.48/p.79 FT-R42W Square Head Type Fiber p.51/p.81 Liquid Detection
p.19/p.36/p.48/ FT-R43 p.15/p.37/p.51
FT-42S Sleeve Fiber
p.79/p.105 FT-R44Y Square Head / Chemical / p.15/p.29/p.37/
FT-42W p.12/p.36/p.48/ FT-R60Y Oil-resistant Fiber p.52/p.82 Fiber
Options
FT-43 p.79/p.105 p.16/p.37/p.52/
Threaded Type Fiber FT-S11 Cylindrical Fiber
p.12/p.36/p.49/ p.82
FT-45X
p.79/p.105 p.11/p.37/p.52/
FT-S20 Super Quality Fiber Semi-custom
p.25/p.36/p.49/ p.82 fibers
FT-A11
p.79/p.105 p.16/p.37/p.52/
FT-S21
p.25/p.36/p.49/ p.82
FT-A11W Cylindrical Fiber
Wide Beam Fiber p.79 p.16/p.37/p.52/ Fiber
FT-S21W Dimensions
FT-A32 p.82/p.105
Thru-beam
p.25/p.36/p.49/
FT-A32W p.11/p.37/p.52/ Type
p.80 FT-S30 Super Quality Fiber
FT-AL05 p.82 Retroreflective
Type
FT-E13 p.16/p.19/p.36/ p.16/p.37/p.52/
Cylindrical / Sleeve Fiber FT-S31W Reflective
FT-E23 p.49/p.80 p.82/p.105 Type
Cylindrical Fiber
FT-F93 Liquid Leak / Liquid Detection Fiber p.35/p.36/p.49 p.16/p.37/p.52/ Others
FT-S32
p.82
p.19/p.37/p.52/
FT-V23
p.82
Amplifiers
p.19/p.37/p.53/
FT-V24W Sleeve Fiber
p.82 FX-500
series
FT-V25 p.19/p.37/p.53/ FX-100
FT-V30 p.83 series
p.16/p.37/p.53/
FT-V40 Cylindrical Fiber
p.83
Chemical / Oil-resistant p.29/p.37/p.53/ INDEX
FT-V80Y
Fiber p.83
114
114

New product INDEX


introduction
Tough FT-Z20HBW p.74/p.96/
Fiber MS-DIN-E End Plate
FT-Z20W p.20/p.37/p.53/ p.102/p.110
FT-Z30 p.83 MS-EX3 FX-MR2 Mounting Bracket p.69
Fiber FT-Z30E
Selection MS-FD-2 p.33/p.44/p.69
Guide FT-Z30EW Fiber Mounting Bracket
Flat Type Fiber
Model FT-Z30H MS-FD-3 p.69
Choose FT-Z30HW p.20/p.37/p.54/ MS-FD-F7-1 FD-F71 SUS Mounting Bracket
by shape/ p.35
application FT-Z30W p.84 MS-FD-F7-2 FD-F71 PVC Mounting Bracket
How to read FT-Z40HBW MS-FX-01Y Liquid Inflow Prevention Joint
Model No
Earlier models FT-Z40W MS-FX-02Y Protective Tube Extension Joint
comparison p.35/p.45
table Chemical / Oil-resistant p.29/p.37/p.54/ MS-FX-03Y Fiber Mounting Joint
FT-Z802Y
Fiber p.84 MS-FX-YF Joint Internal Ferrulre
FTP-500
Fibers FTP-1000
Super
Quality
FTP-1500
FTP-N500
Protective Tube
(For Thru-beam Type Fiber)
p.45/p.66 R
FR-KZ50E/KZ50H
Threaded FTP-N1000 RF-003
Type Exclusive Reflector p.44/p.69
FTP-N1500
Square Head RF-13 Reflective Tape
Type Photo-terminal for
FV-BR1 p.33/p.44/p.66 RF-210
Cylindrical Vacuum-resistant Fiber
Type RF-220 Reflector p.45/p.69
FV-LE1 Vacuum-resistant Expansion Lens
Sleeve p.33/p.42/p.66 RF-230
FV-SV2 Vacuum-resistant Side-view Lens
Flat FX-101
Type
Small
FX-101-CC2
Spot FX-101P
Narrow FX-101P-CC2 Digital Fiber Sensor p.102/p.103/
Beam
FX-102 FX-100 series p.104/p.110
Wide
Beam FX-102-CC2
Convergent
Reflective FX-102P
Type
Retroreflective
FX-102P-CC2
Type FX-501
Chemical / Oil- FX-501P p.74/p.76/p.77/
resistant
Heat-
FX-502 Digital Fiber Sensor p.96
resistant FX-502P FX-500 series
Vacuum- FX-505-C2 p.74/p.76/p.78/
resistant
Liquid Leak /
FX-505P-C2 p.96
Liquid Detection FX-AT15A Fiber Single-core Holder p.45
FX-AT2
FX-AT3
Fiber FX-AT4 Fiber Attachment
Options p.44/p.67
FX-AT5
FX-AT6
Semi-custom
FX-CT2
Fiber Cutter
fibers FX-CT3 p.44
FX-LE1 Lens for Thru-beam Type
p.42/p.67
FX-LE2 Fiber
Fiber FX-MB1 FX-500 Fiber Amplifier Protection Seal p.75/p.76
Dimensions
Thru-beam
FX-MR1
p.23/p.43/p.67
Type FX-MR2
Lens for Reflective Type
Retroreflective FX-MR3
Type Fiber
Reflective
FX-MR5
Type FX-MR6
p.23/p.43/p.68
Others FX-MR7 Square Head Type M3,
FX-MR8 Reflective Type Fiber &
FX-MR9 Spot Lens
Side-view Lens for
Amplifiers FX-SV1 p.42/p.69
Thru-beam Type Fiber
FX-500
series

M
FX-100
series

MS-AJ1-F Universal Sensor Mounting


p.45
MS-AJ2-F Stand
INDEX
MS-DIN-2 FX-500 Amplifer Mounting Bracket p.75/p.96
MS-DIN-4 FX-100 Amplifer Mounting Bracket p.102/p.110
115
116
Communication Unit for Open Network

The digital sensor can be connected directly


to the 3 types of open network!
Other types of analog input sensors can also be connected!

Fiber Sensor Guide Book


Scattered digital sensors can be centrally managed and set through an open network.

Applicable Digital Fiber Sensor Digital Laser Sensor Digital Pressure Sensor
Digital Sensor

GA-311 GH series

DPS-400 DPH-100
LS series

FX-500

Please contact ..........


Panasonic Industrial Devices SUNX Co., Ltd.

All Rights Reserved Panasonic Industrial Devices SUNX Co., Ltd. 2014

No. CE-FIBERGUIDE-1-7 June, 2014 Specifications are subject to change without notice. Printed in Japan

You might also like