Professional Documents
Culture Documents
Conduction Losses
Switching Losses
Multi-level
31% 32%
2- level
26% 74%
Q
Reactive Power Reference
0.20 Q4 98
0.10
0.00 Q3
96
-0.10 V1 V2
V 550Vdc
V3 V4
-0.20 94 650Vdc
LVRT Q2
750Vdc
Zone
Q1 850Vdc
92
950Vdc
0 5 0 5 0
0.9 0.9 1.0 1.0 1.1 90
0 20 40 60 80 100
Grid Voltage Load Capacity (%)
Display
Operation
Panel
Emergency 29.5
Stop Button
Handle
1900
Air Flow
Ventilation
Air Filter
* Dimentions of 1000 kW only.
Floor Level
50
OPEX reduction: High efficiency and low loss with reduced DC current
Reduced footprint
Natural Cool Air
Fan-less Mode
Environmental conditions
Enclosure protection IP44 / IP54 (Electronic Circuit)
Installation Outdoor
Ambient temperature range -20° ~ 50°C* (-4 ~ 122F)
Protective functions
Input (DC) side Ground fault, DC reverse current, Over voltage, Over current
Grid (AC) side Anti islanding, Over current, Over/under voltage, Over/under frequency
Grid assistance Reactive/active power control, Power factor control, Fault ride through (optional)
Fault analysis Fault Event Log, Waveform Acquisition via Memory Card
Compliance IEC-standard
Std. control power supply From Inverter Output and Capacitor Backup Circuit (3 Sec. Compensation)
Real-time data acquisition and role based supervisory High-resolution historical data storage facilitates
control diagnostic analysis and troubleshooting
Historical data collection & analysis and Comprehensive security model allows personalized
user-configurable security mode access based on user login
Communication using all industry standard protocols Modular and scalable to support easy expansion with
minimal engineering effort
REMOTE CONNECTIVITY
1985 1985
1 MW Inverter 150kW PV Inverter
Largest PV Inverter in the world Running satisfactorily till date
More than
660 MW
installed
within India
2015 2016
20 MW Solar Power Pant
Development History
2500kW/1500V IEC
and Outdoor
1000kW IEC 1833kW/1000V IEC
Certification and Outdoor
LSPV-PCS
2012 500kW / 630kW / 750kW
LSPV-PCS
2008 Development Project
20kW-50kW
with Commercial 1997
Freq. Isolation
Transformer-less
1995 PCS for Residence
New Islanding
Protection 1994
1986 Commercial /
1991 High Frequency Isolation
NEDO
Sun Shine Project 1986
TOSHIBA MITSUBISHI
(TOSHIBA (MITSUBISHI
CORPORATION) CORPORATION)
established in established in
1896 1921
Tokyo Electric Co. Ltd. Mitsubishi Electric
Corporation
Our core technologies lie in the power electronics which transforms and control
the required electric power, and the engineering that extends from planning to
operations of the plant as a whole. Our cutting edge technology in these core areas
contributes to production and environment management. “We make production
possible”. We are TMEIC.
Manufacturing Facility
Our world-class manufacturing plant has the state-of-the-art production, testing facility, quality, SCM
capabilities and products that meet IEC standards. It has well trained employees having expertise in
development of UPS systems, PV inverters and M V drives.
It is our endeavour to bring full capabilities of our Japanese operations to India as we take on the new
challenge of building a better tomorrow for India.
TMEIC Industrial Systems India Private Limited
Corporate Office:
The Millenia, Tower A, 10th Floor, #1 & 2, Murphy Road,
Halasuru, Bengaluru 560 008. India.
Tel.: +91 80 675 15599
Registered Office:
Unit #03-01, Third Floor, Block 2, Cyber Pearl, HITEC City,
Madhapur, Hyderabad 500 081. India.
Tel.: +91 40 443 40000
PUNE: BENGALURU:
412-413, Fourth Floor, #85, Kaniminike Village, Kengeri Hobli,
Ganga Osian Square, Wakad, Bangaluru South Tal. 560 074. India.
Pune 411 057. India. Tel.: +91 80 674 66000
Tel.: +91 20 679 05700
TMIND/PV/2016/01
DELHI / GURGAON:
Unit #105, First Floor,
Tower A, Park Centra, Sector 30,
Gurgaon 122 003. India.
Tel.: +91 124 403 4966
Enquiry: pv@tmeic.in
URL: www.tmeic.in Specifications are subject to change without prior notice.