The Octave-band method of hearing protection calculation uses:


• Octave-band attenuation and standard deviation data (available from the
• Octave-band workplace noise levels (un-weighted values)
HEARING PROTECTOR Make/Model:

Frequency (Hz) 63 (opt.) 125 250 500 1000 2000 4000 8000
Mean attenuation (dB) 13.3 9.6 12.5 25.3 33.4 33.3 37.0 33.7
Standard deviation (dB) 4.1 3.1 3.7 4.3 1.5 2.5 3.4 4.9
Assumed protection (dB) 9.2 6.5 8.8 21.0 31.9 30.8 33.6 28.8

WORKPLACE NOISE Location/Machine:

Frequency (Hz) 63(opt.) 125 250 500 1000 2000 4000 8000
Unprotected Spectrum (dB) 75.0 84.0 86.0 88.0 97.0 99.0 97.0 96.0
Protected Spectrum (dB) 65.8 77.5 77.2 67.0 65.1 68.2 63.4 67.2

Unprotected noise level at the ear LA 104.0 dB(A)


Protected noise level at the ear L' A 74.7 dB(A)
HSE recommended value for the
L' + 4 79 dB(A)
likely noise level at the ear A
Protection rating: Good