Ficha Tecnica - Flujometro F-300
Ficha Tecnica - Flujometro F-300
F-300M
Clamp-on Insertion Mount
Dual PN10 / PN16 scale
Features:
! Dual PN10/PN16 scale printed on both sides of the meter. ! One piece machined acrylic body.
! 32mm through 200mm pipe sizes. ! Mounts to existing pipe. No unions or adapters required.
! Flow rates from 30 to 5100 LPM. ! Models for mounting on horizontal pipe.
! Corrosion resistant 316SS or PTFE internal float materials. ! Mounting clamps and gasket included.
Specifications:
Pipe Requirements: ...... Metric pipe size (DIN 8062) Full scale accuracy: .............. +/- 10%
Max. Bar (psi): ............... 10.3 Bar (150 PSI) @ 21o C (70o F) Power requirement: .............. No power required
Fluid temp. range: ........ 32o to 110o F/ 190o F (88o C) @ 0 PSI Enclosure: ............................. IP56 (NEMA 4X)
Ambient temp. range: ...32o to 110o F/ -10o to 43o C Approximate shipping wt: ... 32mm - 110mm units: 0.45 kg (1 lb)
Note: Temperature & Pressure ratings of meter only. Actual pipe rating may vary. 110mm - 200mm units: 0.91 kg (2 lb.)
Materials of Construction:
Meter Body: ...........Cast Acrylic Gasket: .................. Neoprene
Float: ......................Standard range models = 316SS Pipe Clamp: ...........300 series Stainless Steel
Low range models = PTFE Pitot screw: ...........(32mm-110mm models only) 300 series stainless Steel
Installation Requirements:
Minimum Straight Pipe Length Requirements MINIMUM
OUTPUT
LENGTH
elbows, tees, valves, etc., in the flow stream. Install the meter in a
FLOW
straight run of pipe as far as possible from any disturbances. The FLOW I.D.
distance required for accuracy is 10 times the nominal pipe diameter MINIMUM MINIMUM
before the meter and 4 times the nominal pipe diameter after the meter. INPUT
LENGTH
OUTPUT
LENGTH
I.D.
MINIMUM
INPUT
Example of Minimum Straight Pipe Length Requirements F-300 SERIES LENGTH
Nominal Pipe Diameter Minimum Inlet Pipe Length Minimum Outlet Pipe Length
FLOW
MINIMUM
! F-300M series meters must be mounted at the vertical (twelve INPUT
LENGTH
o'clock) position on horizontal pipe only. No Horizontal Mount
! The pipe must be completely full of water at all times.
! FLOW I.D.
See the minimum straight length of pipe requirement chart above.
FLOW
! The meter can accurately measure flow from one direction only. MINIMUM MINIMUM
INPUT OUTPUT
LENGTH LENGTH
Vertical Mount
Blue-White
R
40 110 62 63 152 40
TEMPERATURE
A 50 110 62 Millimeters
o
61 C (142 F)
o
63 110 62 A
75 110 62 o o
48 C (118 F)
FLOW
90 110 62
110 110 62 34oC (94oF)
160 108 62
200 108 62 o o
21 C (70 F)
0 2.1(30) 4.1(60) 6.2(90) 8.3(120) 10.3(150)
Millimeters STATIC PRESSURE BAR (PSI)
B