COUPLING LENGTH

COUPLING
COUPLINGLENGTH
LENGTH

MAKE-UP LOSS
MAKE-UPLOSS
MAKE-UP LOSS

WALL
WALL
WALL
THICKNESS
THICKNESS PIPE
THICKNESS PIPE
PIPE ID
IDID
PIPE
PIPE
OD
PIPE
OD
OD
COUPLING
COUPLING
COUPLING
OD
OD
OD

TIMING
LINES

5.495 '' OD - 20.22 lb/ft


SEAL-LOCK HT
L-80
PIPE
PLAIN END WALL INSIDE DRIFT PLAIN END LONGITUDINAL INTERNAL COLLAPSE
WEIGHT THICKNESS DIAMETER DIAMETER AREA PLAIN END YIELD YIELD
LB / FT INCHES INCHES INCHES SQ. INCHES LB PSI PSI

20.02 0.365 4.765 4.640 5.882 470,600 9,300 9,030

STANDARD O.D. CONNECTION PERFORMANCE RATINGS


COUPLING COUPLING MAXIMUM MAXIMUM LONGITUDINAL LONGITUDINAL
OUTSIDE CRITICAL BEND COMPRESSION YIELD PARTING LEAK RESISTANCE LIMIT
DIAMETER AREA RATE LOAD STRENGTH LOAD INTERNAL EXTERNAL
INCHES SQ. INCHES DEG/100FT LB LB LB PSI PSI

5.950 5.399 50 316,500 1


431,900 2
512,900 14,030 12,610

TORQUE
*MILL END WINDOW FIELD END MAKE-UP YIELD
MINIMUM MAXIMUM MINIMUM OPTIMUM MAXIMUM MINIMUM
FT-LB FT-LB FT-LB FT-LB FT-LB FT-LB

1,200 5,800 5,700 6,500 7,300 16,400


*NOTE: MILL END IS TO BE MADE UP TO POSITION. FINAL TORQUE SHOULD FALL WITHIN THE
WINDOW SHOWN ABOVE. MAKEUP TORQUE MAY BE INCREASED TO 80% OF MINIMUM YIELD TORQUE
FOR HIGH TORQUE APPLICATIONS.
CONNECTION DATA
PIN
COUPLING MAKE-UP THREAD FLANK
CRITICAL
LENGTH LOSS AREA
AREA
INCHES INCHES SQ. INCHES SQ. INCHES

8.534 4.267 5.882 10.146

1
BASED ON 80 KSI MINIMUM YIELD STRENGTH
2
BASED ON 95 KSI MINIMUM TENSILE STRENGTH

BOSSRATE.XLS - V.2 Rev. Date: 10/26/2011