DOC No: NPD-Accessories-88-(ELRD)-2018-02-0017 rev R01

SPECIFICATION SHEET

Product : Accessories Model : ELRD 1552A Date (Org): 20.02.2018

Document category : Marketing TPL No. : Z01481 Date (Rev): 31.05.2018

S.No Description Unit Data


1 Air flow rate at nominal condition * cfm 1550
o
2 Pressure Dew Point at nominal condition * C 2 to 4
o
3 Nominal ambient temperature C 35
o
4 Min... Max ambient temperature C 5...50
o
5 Nominal inlet air temperature (max) C 45 (60)
6 Nominal inlet air pressure Bar.g 7
7 Max...inlet air pressure Bar.g 16
8 Air pressure drop-Δp bar 0.2
9 Inlet -Outlet connections -- 5"NB ANSI B16.5 150# Flg
10 Refrigerant type -- R134a
11 Refrigerant quantity kg 9.0
12 Cooling air fan flow m³/h 5415
13 Standard Power Supply Ph/V/Hz 3/415/50
14 Nominal electrical consumption kW 8.379
15 Full Load Amperage FLA A 29.92
16 Max noise level at 1m dbA 80
17 Weight kg 650
18 Overall size mm 1300 x 1800 x 1650

Note:

* - The nominal condition refers to an ambient temperature of +35°C with inlet pressure at 7 bar g
and air inlet temperature +45°C

Prepared by Saminathan C Approved by Subramanian K


All data and information in this sheet are confidential and property of ELGi EQUIPMENTS LIMITED
This is a System Generated Document and hence Signature is not required
Page 1 of 1