www.oblighting.com Medium Intensity White
Obstruction Lighting Standards
(FAA Style D)
& Sample Lighting Kits
Visit the site today to find quality product
information, general industry standards,
technical specifications and troubleshooting Medium Intensity Dual Obstruction
guides. Lighting Standards (FAA Style E)
& Sample Lighting Kits
FG2009B - Red
FG3000B - Dual
LEDGuard - Red
Medium
Intensity
Products
HUG
GHEY
Y & PH
HILLIP
PS, LL
LC.
FlashGuard™
™ 3000BB
Dual Medium
M m Intenssity Stroobe System
FAA Tyype: L-864
4/865 Mediium Intenssity Lightinng
ICAO Type:
T Typee A/B Meddium Intenssity Obstaccle Light
ETL Ceertified:
FAA Advvisory Circu
ular 150/5345-43F
Compliiant to:
ICAO Annnex 14, MIIL-C-7989, DGAC
D of Mexico, CAR
621.19
Use:
Medium intensity ob bstruction ligghting systemms are typicaally used on structures beetween 150’
(45M) annd 500’ (150 0M) above grround level to t provide aviation safetty. The use of
o a medium m
intensity white strobee during the daytime typpically eliminnates the neeed to paint thhe structure with
aviation orange
o and white
w stripess. The use off a red flashiing beacon at
a night proviides a
“communnity friendly y” light. Hugghey & Philliips medium intensity obbstruction ligghts are desiggned
for lighting tall structtures such ass communication, television and raddio towers, chhimneys, cooling
towers, taall buildingss, catenary riiver crossinggs and bridgees.
System
m Features:
• Single flaashhead provvides dual red/white meddium intensitty operation with no movving
parts.
• Dual flashhtubes and dual
d trigger transformers
t s provide nigght time reduundancy - noo
single poiint of failuree in the flashhhead
• Precise op ptics minimiize ground sccatter light
• Alarm con ntacts providded for connnection to anny monitoring system
• Rugged design
d of flasshhead and power
p supplyy is suitable for outdoor installation in
any climaate
Flashheead Features:
• Upper optics provides redd flashing beeacon lightinng
U
• L
Lower optics provides meedium intenssity white strrobe lightingg
• Iddentical strob r and whitte eliminatess extra spare parts
be tube for red
• Innternally trig fo long-life and maximuum efficiencyy,
ggered Xenoon strobe tubbes utilized for
w
without creatiing corrosive ozone
• Parabolic refllector/linear strobe tubess optics com mbination proovides very precise
p opticcs
annd blocks grround scatterr light in botth red and whhite operatioon
• L
Lens raises annd locks in place,
p providding easy acccess to strobbe tubes
• O
Only five commponents used in flashheead - minimaal maintenannce requiredd at top of
sttructure
• D flashtub
Dual bes and triggger transform
mers provide night time redundancy
r
• Safety interlo ock switch inncluded
• N moving parts
No
• H
High temperaature, UV ressistant acrylic flashheadd lens
Power Supply
S Feeatures:
• Provides pow wer electroniccs, timing ciircuitry, and monitoring for lighting system
• A
Automatic daay/night intennsity controll
• M
Manual inten
nsity overridee
• E
Easily accessible componnents
• Plug-in-play circuit
c cardss
• C
Control and monitoring
m fo up two siddelight levells with four steady burniing obstructiion
for
liights
• Fail-safe mon nitoring systeem with up tot five remote alarm conntacts
• Stainless steeel NEMA 4X X enclosure
• L power consumption
Low
Dimenssions:
Specificcations:
Day Mode (White) 20,0000 candela ± 255%
Night Mode (Red) 2,0000 candela ± 25%%
Backup Nighht Mode (Whitte) 2,0000 candela ± 25%%
P
Photometric Beam Spreaad 3° miinimum
Horizontal Coverage
C 360°, omni-directionnal
Ground Scattter <3% Light
L Output at
a -10° Verticall
Flash Rate 40 FPPM Day & Bacckup White Nigght
24FPM M Red Night
Temperaturee -55° to
t +55° C (-67°° F to +130° F))
Will withstaand exposure too 95% relative
r humidity
Environmental Windd-blown rain direction
Salt-laden atmospheere
Windd Speed - 240kpph (150mph)
Weight, Flasshhead 16 kgg (34 lbs)
Weight, Pow
wer Supply 32 kgg (70 lbs)
Mechanical Power Supply Enclosure 304 Stainless
S Steel - standard
316L Stainless Steel - optional
Flashhead Lens
L Material High Temp/UV Ressistant Acrylic
Input Voltagges 120, 230/240,
2 277, 480
4 VAC
24VDDC
Input Frequeencies 50 or 60 Hz
Power Consumption, Day 208 Watts
W
Electrical Power Consumption, Nighht 133 Watts
W
Power Consumption, Backkup 77 Watts
W
Peak Inrush Current 7A @ 120VAC
Available Alarm
A Contacts Poweer Failure, Modde Status, Strobbe Failure,
(form C dry--contact) Sideliight #1 Fail, Siidelight #2 Faill
Flash
hGuard™ 20000B
White
e Mediu
um Inte
ensity Strobe
S S
System
m
Red Medium
M m Intenssity Strrobe Sy
ystem
FAA Tyype: L-864
4 or L-865
5 Medium
m Intensityy Lighting
ICAO Type:
T Typ
pe A or B Medium
M In
ntensity Obstacle
O L
Light
ETL Cerrtified:
FAA Advissory Circular 150/5345-43F
ant to:
Complia
ICAO Ann
nex 14, MIL-C
C-7989, DGAC
C of Mexico, CAR 621.19
Use:
Medium in ntensity obstrruction lightingg systems are e typically use
ed on
structuress between 150 0’ (45M) and 500’ (150M) above a ground d level to
provide avviation safety. The use of a medium inte ensity white strobe
s during
the daytim
me typically elliminates the need to paintt the structure e with aviation
n
orange an nd white stripees. The use ofo a red flashing beacon att night
provides a “community y friendly” light. Hughey & Phillips
P mediu um intensity
obstructio
on lights are designed
d for lighting tall strructures such as
communiccation, televis sion and radio o towers, chim mneys, cooling g towers, tall
buildings, catenary riveer crossings and
a bridges.
System Features:
• Single flaashhead provvides white oro red mediuum intensity operation with
w no movinng
parts.
• Precise op ptics minimiize ground sccatter light
• Alarm con ntacts providded for connnection to anny monitoring system
• Rugged design
d of flasshhead and power
p supplyy is suitable for outdoor installation in
any climaate
Flashheead Features:
• Innternally trig fo long-life and maximuum efficiencyy,
ggered Xenoon strobe tubbes utilized for
w
without creatiing corrosive ozone
• Parabolic refllector optics and linear strobe
s tube optics
o combinnation proviides very preecise
opptics and bloocks ground scatter lightt in both red or white operation
• Lens
L raises an
nd locks in place,
p providding easy acccess to strobbe tubes
• Only
O three co
omponents used
u in flashhhead - minim
mal maintenaance requiredd at top of
sttructure
• Safety interlo ock switch inncluded
• No
N moving parts
• High
H temperaature, UV ressistant acrylic flashheadd lens
Power Supply
S Feaatures:
• Provides pow wer electroniccs, timing ciircuitry, and monitoring for lighting system
• Automatic
A daay/night intennsity controll
• Manual
M inten
nsity overridee
• Easily
E accessible componnents
• Plug-in-play circuit
c cardss
• Control
C and monitoring
m fo up two siddelight levells with four steady burniing obstructiion
for
liights
• Fail-safe mon nitoring systeem with up tot five remote alarm conntacts
• Stainless steeel NEMA 4X X enclosure
• Low
L power consumption
Specific
cations:
ETL Certifiied:
E
F
FAA Advisoory Circular AC
A 150/53445-43F
Compliant to:
C t
C
Canadian Avviation Regu
ulation (CAR
R) 621.19
I
ICAO Annexx 14, MIL-C C-7989, DGAAC of Mexicco
Use:
U
H
Hughey & Phhillips flashiing red beacons are designed to meeet internationnal
a
aerial navigaation requiremments for obbstruction ligghting appliccations. FAA
A
a ICAO appplications in
and nclude televvision, radio, communicaations,
m
microwave, t
transmissionn line towerss and other objects
o extennding greaterr
t
than 150' aboove ground level.
l
Design:
D
T optical system
The s consiists of four red Fresnel leenses, designned to provide a definitee360º horizontal
b
beam. The twwo lamp receeptacles are mounted to properly position two 6220 or 700 Watt W Mogul pre-focus
p
b
beacon lampps, thus proviiding correctt beam distriibution in acccordance wiith FAA andd ICAO
s
specification
ns. A three-teerminal connnecting blockk is mountedd in the basee, allowing each lamp to be
individual feed and monittored if desirred. Internal wiring is heeat-resistant insulated fleexible wire thhat
t
terminates att the connectting block. Unless
U otherwwise orderedd, beacons arre furnished with a five--foot
length of #122-3 conducto or Neoprene cable, enterring the basee through a1”” watertight connector. Conduit
C
m be used by removin
may ng the watertight connecttor and discoonnecting the cable. Thee beacon is hinged
h at
t center beetween the up
the pper and low wer lens asseemblies to prrovide readyy access for inspection
i annd lamp
r
replacement. . The hinge rings,
r butterffly gasket, and
a locking clamp
c maintain a weatheerproof centeer seal.
Features:
F
• C Constructed of
o heavy alum minum castiings with staainless steel hardware
h annd heat resisttant
Fresnel glass lenses
• Concave
C basee with drain port at loweest point prevvents moistuure accumulaation
• Neoprene
N gasskets providee long life unnder extremee temperaturres
• Designed
D for easy lamp replacement
• Weatherproof
W f hinge ringss, butterfly gasket
g and loocking clampp
M
Model:
K
KG114F000
01 FA
AA Type L--864, Flashing Red Beaacon, 120/2330V 50/60Hzz
Lamps:
L
LH6220120GE Lamp, Beacon, 620W, 120V
LH7000230HDT Lamp, Beacon, 700W, 230V
Otherr lamps avaiilable upon request
r
S
Specification
ns:
Beam Sp
pread 360° Horizzontal
3° Vertical
Photometric
Effectivee Intensity ≥ 1,600 caandela (ICAO)
2,000 ± 25 5% (FAA)
Temperrature ‐55° C to ++55° C
‐67° F to ++ 130° F
Humiditty 95% relatiive humidity
Enviro
onmental
Will withstand expossure to: Wind‐blow wn rain from any angle
Salt‐laden atmosphere
Wind speeed of 240kph (150mph)
Lens Heat resistant glass, red
Frame Cast aluminum with staainless
steel hardware
Dimensiions 850mm H x 305mm D
Mecchanical
(33.5” H x 12” D)
Weight 33kg (73 lbs)
Mountin
ng Pattern Quantity 4 4 holes @
15.7mm (1 13.25”) bolt ccircle
DL
WT
SK
CB
ETL Certifiied:
E
F
FAA Advisoory Circular AC
A 150/53445-43F
Compliant to:
C t
C
Canadian Avviation Regu
ulation (CAR
R) 621.19
I
ICAO Annexx 14
M
MIL-C-7989 9
D
DGAC of Mexico
M
Use:
U
H
Hughey & Phhillips flashiing red beacons are designed to
m internattional aerial navigation requirements
meet r s for
o
obstruction lighting appllications. FAAA and ICAO O
a
applications include televvision, radioo, communiccations,
m
microwave, t
transmission n line towerss and other objects
o
e
extending grreater than 1550' above grround level.
The L864LE
T m be used in conjunctiion with a beeacon flasher or tower lighting contrrol in
ED beacon must
o
order to achiieve the prop
per flash ratee. Hughey & Phillips Serries 800 Beaacon Flashers provide ann
e
economical s
solution and our Mechannical Flasherrs provide a flasher that isi immune too AM towerr RF
f
frequencies. The H&P 9L LC series ligghting controols provide the
t most com mplete solutiion. Hughey &
P
Phillips C series lightiing controls should be used when seeveral beaconns need to flash simultanneously.
9LC
9
9LC controlss also includ
de a photocelll for automaatic day/nighht operation, and providee alarm contacts for
r
remote moniitoring. Speccifications onn any of the above controls are availlable from Hughey
H & Phhillips
O
Obstruction L
Lighting. Viisit www.obllighting.comm for additionnal informattion and speccifications on
o the
9
9LC series.
M
Models:
L
L864LED-0 01 FA
AA Type L--864, LED Flashing
F Red Beacon, 120/230V
1 5/660Hz, 85W
L
L864LED-0 03 FA
AA Type L--864, LED Flashing
F Red Beacon, 24-48VDC
2
M
Mechanical Dimensionss:
S
Specification
ns:
ETL Certifiied:
E
F
FAA Advisoory Circular AC
A 150/53445-43F
Compliant to:
C t
C
Canadian Avviation Regu
ulation (CAR
R) 621.19
Use:
U
H
Hughey & Phhillips L864
4LED-001GP PS is designeed specificallly
f the growiing Wind En
for nergy market. This unit is the lightest
f
fully integratted GPS, Photocell, Monnitored LED D red beacon in the indusstry. The unit utilizes thee FAA
s
standard mouunting bolt pattern
p for eaasy replacem
ment of olderr lighting fixxtures using existing braccket.
Features:
F
• Lightest LED fixturee at under 255 pounds
• Quick annd easy instaallation on neew or existinng Wind Turrbines
• Integrateed GPS SYNNC, Photocell, Power Suppply, & Monnitoring
• Low Pow wer Consump ption
• Built in Surge
S Protecction
• Advanced Data Processor – 6 moonths of dataa captured foor performannce evaluatioons
• Five (5) Warranty
W – Industry’s
I fiist available 10 Year Waarranty (ask for
f details)
Specification
S ns:
Inputt Voltage – 120/240VAC
1 C 50/60 Hz
Wattaage – 48 Waatts
Weigght – 24 pounnds
Dimeensions – 15” H x 10.5” W
Mounnting – FAA A required 133.25” Bolt Paattern
ET
TL Certified
d:
FA
AA Advisoryy Circular AC
C 150/5345-43F
Coompliant to:
Cannadian Aviaation Regulattion (CAR) 621.19
6
ICAAO Annex 14,
1 MIL-C-7 7989,
DGGAC of Mexxico
Usee:
Higgh intensity obstruction lighting systtems
aree typically ussed on structtures taller thhan
5000’ (150M) abbove ground d level to proovide aviatioon safety. Thhe use of a hiigh intensityy lighting sysstem
typpically eliminnates the neeed to paint thhe structure with
w aviationn red and whhite stripes. Honeywell high h
inteensity obstruuction lights are designed for lighting tall structuures such as television annd radio tow wers,
chiimneys, coolling towers, tall buildinggs, catenary river
r crossinngs and bridgges.
Design:
Thee StrobeGuaard™ High Intensity
I Ligghting System m consists off multiple flashheads controlled by a single
lighhting control. The quanttity and locattion of flashheads used is i generally determined
d b the structture’s
by
heiight and diammeter. The StrobeGuard™
S ™ controllerr constantly monitors thee operation ofeach
o flashhhead, and
proovides alarm
m contact clossure upon anny failure. Thhe control auutomaticallyy switches beetween day, twilight,
andd night intennsities by thee use of a callibrated phottocell. StrobeGuard™ flashheads inccorporate a louver
l
sysstem to minim mize ground d scatter lighht, resulting in
i a “commuunity friendlyy” lighting system.
s The
StrrobeGuard™ ™ system can n be combineed with a redd lighting sysstem for areaas where whhite lighting at night
maay be undesirrable.
Feaatures:
• Fail-safe monitoring
m system
s • Eassily accessible replaceabble componennts
• Parabolic Optics miniimize ‘grounnd scatter’ • Pluug-in-play cirrcuit cards
light: < 3%
% of peak in ntensity at -110° • Rem mote alarm contacts
c
• Two-wiree cable for sy ync, mode annd monitorinng • Stainless steel NEMA
N 4X enclosure
e
• Safety intterlocks in eaach flashheaad • Verrtical level inndicator andd adjustment system
• Long-life internally trriggered stroobe tubes • Low w power connsumption
• Automaticc three-levell intensity coontrol • Minnimal wind loading
l and weight
• Manual inntensity overrride
StrobeGuarrd™ Contro
S ol
S
StrobeGuard d™ controls contain the flash
f intervaal and timingg circuits, inttensity selecction controlss and
m
monitoring c
circuitry withh status indiccators. The StrobeGuard
S d™ control system
s is dessigned to opperate up
t 24 flashheeads at a disttance of up to 2500 feet (760 M), usiing a noise-rresistant com
to mmunicationns
f
format. Eachh control is equipped
e witth the necesssary manuallly operated controls
c to teest all modess of
o
operation. Bii-color green
n/red LEDs are a providedd to indicate proper operation or faullt of each flaashhead.
Flashhead Advantages
F A
E
Each StrobeGGuard™ Flaashhead conttains a flashttube, reflectoor assembly,, power suppply and triggger
c
circuitry osure. All circuit boards are plug-in--play, meetinng all physiccal and electrical
in a single enclo
r
requirements s of MIL-I-440658B incluuding conforrmal coatingg for weatherr resistance. StrobeGuardd™
F
Flashheads a supplied with lightninng arrestors capable of withstanding
are w g repeated 100,000-amperrecurrent
s
surges. The flashheads
f utilize
u an inteernally triggeered strobe tube
t that elim
minates ozonne, a corrosivve agent
t can dam
that mage wiring and
a circuitryy over time.
S
Specification
ns:
E
ETL Certifiied: FAA AC
C 150/5345--43F
C
Compliant t ICAO An
to: nnex 14, CA
AR 621.19,
MIL-C-79
989
Use:
U
T Hughey & Phillips L-810
The L Obstruuction Lightt low intensitty
o
obstruction lighting prodducts are dessigned to meet
internationall aerial navig
gation requirrements for obstruction
o
lighting appllications. Appplications innclude televiision, radio,
c
communicati ions, microwwave, transmmission line towers,
t windd
c
cones and othher objects requiring
r navvigational orr obstructionn
lighting. Thee family of lo
ow-intensityy lighting prooduct consistts
o single andd double ligh
of hts with varioous features to meet youur
s
specific appllication needds.
M
Models
OB20A31
O Sin
ngle, 3/4” Boottom Hub
O
OB20A41 Sin
ngle, 1” Botttom Hub
O
OB21A31 Sin
ngle, 3/4” Side Hub
O
OB21A41 Sin
ngle, 1” Sidee Hub
O
OB22A31 Doouble, 3/4” Bottom
B Hub
O
OB22A41 Doouble, 1” Botttom Hub
O
OB24A31 Doouble, 3/4” Side
S Hub
O
OB24A41 Doouble, 1” Sidde Hub
O
OB22A41TM
M1 Doouble, 1” Botttom Hub, Transfer
T Relaay
O
OB24A41TM
M1 Doouble, 1” Sidde Hub, Trannsfer Relay
S
Spare Paarts & Acccessoriess
LH116120G
L GE Lammp, 116W, 120V
L
LH116120SY
YL Lammp, 116W, 120V
L
LH116230D T Lammp, 116W, 230V
2
F
FL02B02810
0 Lenns, Red, Fresnel
X
XLCB4S2000 Lammp Socket, 120V or 2300V
A
A6A0008AGG Neeoprene Gaskket
B
B6A0008AAA Lenns Holder with
w 7” Chainn
6
6A0013SK3 Traansfer Relayy Assembly w/relay
w & soockets
O
OBRL100 Traansfer Relayy
Photometricc Specificatiions
P
Beam
B Spreadd: 360° Horizzontal, 3° Minimum
M Verrtical
Effective
E Inteensity: ≥ 32 Candela
Mechanical Specificatio
M ons
Base
B Materiaal: Cast Alumminum with aviation
a red powder coaat
Lens:
L Heat reesistant clearr glass
Single: 8” x 5.5”
5 x 5.5” (H H x W x L), 4 lbs.
Double:
D 8” x 5.5” x 11.5”” (H x W x L),
L 8.25 lbs.
Environmen
E ntal Specificcations:
Temperature:
T : ±55°C
Humidity:
H 95% relative humidity
h
Will
W withstan nd exposure to
t wind-blow
wn rain from
m any directiion, salt-ladeen atmospherre and
w
wind speeds of
o 240 kph (150 mph).
E
ETL Certifiied: FAA AC
C 150/5345--43F
C
Compliant t ICAO An
to: nnex 14, CA
AR 621.19, MIL-C-7989
M
Use:
U
T Hughey & Phillips L-810
The L Obstruuction Lightt provides ann LED
b
based solutioon to the FAAA L-810 styyle of steady burning lighhts. The
L
L-810 LED is i currently available
a in both
b single and
a double
c
configurationns operating at 120V, 2440V, 277VA AC and also ini a range
o 9-48 VDC
of C. Both conffigurations are a available as original equipment
e
o as a directt replacemen
or nt to the exissting socket/llamp/lens onn H&P L-
8 Incandesscent OB2x Series obstru
810 ruction lightss.
Features:
F
LED based ob
L bstruction ligghts last oveer 15 times loonger than an
a incandesccent light
A
Approximate ly 94% less power than 116 Watt staandard incanndescent lam mp
6 Watt Powerr Consumptiion
A
Available in both
b side andd bottom connduit hubs ata ¾” and 1” NPT
W
Weather resisstant lamp asssembly & housing
h
Self containedd wiring com mpartment on o double unnits eliminatees additionall boxes
O
Operates as a steady burnn or flashing light
R
Resistant to shock
s and vibbration
D
Direct replaceement for exxisting incanndescent fixtuures
5 Year Warraanty
Photometricc Specificatiions
P
Beam
B Spreadd: 360° Horizzontal, 3° Minimum
M Verrtical
Effective
E Inteensity: ≥ 32 Candela
Mechanical Specificatio
M ons
Base
B Materiaal: Cast Alumminum with aviation
a red powder coaat
Lens:
L Heat reesistant clearr glass
Single: 8” x 5.5”
5 x 5.5” (H H x W x L), 2 lbs.
Double:
D 8” x 5.5” x 11.5”” (H x W x L),
L 6 lbs.
Environmen
E ntal Specificcations:
Temperature:
T : ±55°C
Humidity:
H 95% relative humidity
h
Compliant to:
C t FAA AC C 150/5345-443F,
ICAO O Annex 14,, CAR 621.19
Use:
U
9
9LC series liighting contrrols combinee the finest inn
d
digital circuiitry with rugged electrom mechanical
h
hardware to yield
y the ind
dustry’s mosst
c
comprehensi ive obstruction lighting controls.
c
S
Standard moodels are avaailable for alll common FA AA
a ICAO appplications. The
and T 9LCs modular
m desiggn
a
allows for cuustom contro ols for almosst any
c
combination of flashing red beacons and sidelighhts.
A models innclude a NE
All EMA 4 outdooor housing and a
a calibrated photocell
p forr automatic day/night
d sw
witching. A photocell
p override switchh is standardd on all
s
systems, faciilitation trou ubleshooting or maintenaance. All conntrols providde compreheensive status
indicators annd alarm con ntacts for eassy connectionn to remote monitoring
m s
systems.
Features:
F
Contrrols for multtiple beacons flash all beeacons simulltaneously per FAA and ICAO
speciifications
Lighttning protecttion provided by:
– Circuit brreaker protecction to all toower lightingg circuits.
– MOV surrge suppressoors on all inpputs, outputss, and photoccell lines
– Torroidal current senssors isolate tower
t lines from
f monitoring circuitryy
Loadd balance resistor capabillity is availabble
Moduular design allows
a custom
mization forr nearly any application
Dozeens of modells already deeveloped for control of up u to 14 beaccons
Standdard with NEEMA 4 encloosures (NEM MA 4X optioonal upgradee)
M
Models – Paartial listing only
o – Pleasse contact Huughey & Phiillips for more configuraations
Structure Input V
Voltage Sideligh
ht LBR
Moodel # System Lighting Typee Height (50/60Hz) Beacons Strobbes Levelss Capability
9LCA0001000AA FAA A‐0 In
ncandescent 0 ‐ 1500' 12
20V 0 1 No
9LCA1111L00AA FAA A‐1 In
ncandescent 151' ‐ 35
50' 12
20V 1 1 Yes
9LCA2333L00AA FAA A‐2 In
ncandescent 351' ‐ 70
00' 12
20V 3 2 Yes
9LCA3554L10AA FAA A‐3 In
ncandescent 701' ‐ 10
050' 12
20V 5 3 Yes
9LCA4774L10AA FAA A‐4 In
ncandescent 1051' ‐ 14
400' 12
20V 7 4 Yes
9LCD111000AA FAA D‐1 Strobe
S 200' ‐3550' 12
20V 1 No
9LCD2331000AA FAA D‐2 Strobe
S 351' ‐ 50
00' 12
20V 3 No
9LCE11
11L0BAA FAA E‐1 In
nc/Strobe 200' ‐3550' 12
20V 1 1 Yes
9LCE23
33L0BAA FAA E‐2 In
nc/Strobe 351' ‐ 50
00' 12
20V 3 3 Yes
9LCIA0
06000AA I
ICAO A‐0 In
ncandescent 0 ‐ 1500' 23
30V 1 No
9LCIB1
16L00AA I
ICAO A‐1 In
ncandescent 151' ‐ 35
50' 23
30V 1 1 Yes
9LCR00
01000AA FAA A‐0 LED
L 0 ‐ 1500' 12
20V 1 No
9LCR11
11000AA FAA A‐1 LED
L 151' ‐ 35
50' 12
20V 1 1 No
9LCR23
31000AA FAA A‐2 LED
L 351' ‐ 70
00' 12
20V 3 2 No
9LCR35
54000AA FAA A‐3 LED
L 701' ‐ 10
050' 12
20V 5 3 No
AUTO-DAY-AUTO-NIGHT-AUTO
GND
120VAC L1 BEACON #3 BEACONS:
- TWO (2) 620W, 120V or
RED
120VAC L2 - TWO (2) 700W, 230V or
BEACON #2
WHITE
NEUTRAL - ONE (1) LED-type L-864
BLACK
BEACON #1
TOWER SIDELIGHTS:
NEUTRAL SIDELIGHT LEVEL #2 - 1 to 4 116W, 120V or
- 1 to 4 116W, 230V or
SIDELIGHT LEVEL #1 - 1 to 4 LED-type L-810
PHOTOELECTIC
CONTROL
SWITCH SETTINGS
Use:
U
T Hughey & Phillips SERIES
The S 8000 PhotoContrroller and
B
Beacon Flashher providess a low cost, high reliabillity solution
t your lightiing needs. This
to T unalarm med system allows
a for
t user to addd an inline system to thheir conduit run
the r on the
t
tower to conttroller the in
nstalled FAA A beacons annd sidelights.
T systems are factory calibrated annd never neeed
The
a
adjustment. Each systemm utilizes surrge and transsient
c
components and addition nal input linee protection. Normally
c
closed solid state relay configurationn assures “Liights ON” coondition eveen if the circuuitry fails. Red
R LED
p
provides quicck visual verrification off field operattion. And wiith its modullar design, itt allows for quick
q
f
field installattion or retroffit to existinng system is ever
e damageed.
S
Specification
ns: M
Mounting R
Requiremen
nts:
Input Voltagee 120VAC or 2 230VAC, 50/6 60Hz External Dimenssions 4‐1//2" x 4‐1/2" xx 3"
Power Ratingg 2000 Watts continuous d duty Con
nduit Mounteed 1" N
NPT
Peak Currentt Surge 320 Amps, 1 100ms
650 Amps, 1 1 cycle @ 60HHz
Operation Teemperature ‐55° to +55°° C
2.5kV @ 10m ms
Transient Suppression componentss to case
Reliability MTBF over 5 500,000 hrs
Photo Contro ol ON/OFF ON at or abo ove 35 foot candles
OFF at or beelow 58 foot ccandles
Beacon Flash h Rate 30FPM: 2/3 ON, 1/3 OFF
P
Part Numbeers:
S800PC120 – Ph
hoto Controoller, 120VA
AC
S800PC240 – Ph
hoto Controoller, 240VA
AC
S800BF120 – Beeacon Flasher, 120VACC
S800BF240 – Beeacon Flasher, 240VACC
R
Reason for Use:
U
The proper opeeration of electrrical and electrronic devises inn general is bassed on the avaiilability of a reelatively steadyy line
T
v
voltage. This condition
c is usuually met withoout special precaution when the t several connnected loads all a consume a steady
s
a
amount of pow wer. If one or more
m of the loadds are of a varyying or pulsatinng nature, thenn the degree of steadiness of thet line
v
voltage (i.e. linne voltage regulation) will be dependent upoon several factoors – such as:
(1) Thhe voltage regu ulation of the power
p service to
t the installatiion (i.e. is the power
p service a firm-heavy source with
addequate capacity or a soft souurce at the end of a rural line))
(2) Thhe size of the conductors
c betwween the poweer service and the t connected load. l In many cases the size is not
addequate for thee load, thus cauusing a large vooltage drop.
(3) Thhe size and volltage regulationn of the standbby generator.
(4) Thhe relative sizee of the pulsating load as relaated to the totall connected loaad at site.
A of prime importance
Also i is the
t relative sennsitivity of the electronic
e or raadio equipment to the variatioons in the line voltage.
T rules of thee FCC and FAA
The A require the 300mm
3 Beaconn to flash ON anda OFF at a raate between 200 and 40 flashes per
m
minute. The beeacon normally y uses two 620 watt lamps, thhus a pulsating load of 1240 watts. w Assuming a rate of 300 FPM, the
1
1240 watt load is ON for 1-1//3 seconds and OFF for 2/3 seeconds. Due too some inrush current when the t lamps are ON,O the
e
effect on the linne voltage may y be slightly moore severe thann flashing a ressistive load of 1240
1 watts. In some installatiions, the
1
1240 watt pulsaating load may y represent a suubstantial portioon of the total connected loadd. In these cases the variationns in the
liine voltage maay be quite seveere and some corrective
c meanns must be connsidered. Fortuunately, a relatively simple annd quite
e
effective correcctive means is available – a Load
L Balance Resistor.
R This consists
c of a 12200 watt resisttive load whichh is
s
switched ON ass the Beacon lo oad is switchedd OFF and vicee versa.
E
Ease of Installation:
G
General:
The base moounting ring is an aluminnum casting, tapped to acccept the thrreaded rod. The
T T rod is faabricated
f
from 7/8” diaameter mateerial threadedd at one end for insertionn into the moounting ring. The rod iss
s
specially treaated after fab
brication to withstand
w weathering.
Ordering:
O
Lighttning Rod Assembly
A LRB
B58L7510M
M
Lighttning Rod A6A
A0302A13
Mounnting Ring A6A
A0302AA2
Jam Nut
N NH
H7510CB2
KG0910M
K M001
M
Medium In
ntensity Lighting
L Fiixture Sid
de Mount Bracket
B
Fits round
r tower legs from 1--1/4” to 4-1//2”
KG0910M
K M002-02
M
Medium In
ntensity Lighting
L Fiixture Ice Shield Brracket
Fits round
r tower legs from 1--1/4” to 4-1//2
Note:
N Ordeer one brack
ket part num
mber per flaashhead.
J
Junction B
Box: JB00
0000000 Juncttion Box: JC000000000
Specification
S ns Speciffications
I
Inside Dimennsions: 5-3/8
8” Dia., 2-5//8” Depth Inside Dimensionss: 4-7/8” L x 7” W x 4” D
C
Capacity – Seven
S (7) Buuchanan Term minals Capacity – Ten (100) Buchanann Terminals
M Hub Taap – 1” Cond
Max. duit Size Max. Hub
H Tap – 1-1/2” Conduuit Size
J
Junction B
Box: JE00
0000000
Specifications
Insidde Dimensioons: 7-1/2” L x 9” W x 5”
5 D
Capacity – Twelve (12) Bucchanan Term minals
Maxx. Hub Tap –
Right/Leeft – 1” Condduit Size
Top/Botttom – 2” Coonduit Size
J
Junction B
Box: JF00
0000000
Specification
S ns
I
Inside Dimennsions: 10” L x 9” W x 5”
5 D
C
Capacity – 24 Buchanan n Terminals
M Hub Taap –
Max.
Rightt/Left – 1” Conduit
C Size
Top/BBottom – 2”” Conduit Sizze
J
Junction B
Box: JG00
0000000
Specification
S ns
I
Inside Dimennsions: 15” L x 9” W x 5”
5 D
C
Capacity – 36 Buchanan n Terminals
M Hub Taap –
Max.
Rightt/Left – 1” Conduit
C Size
Top/BBottom – 2”” Conduit Sizze
Meth
hod of Speciffying Condu
uit Hub Tap
ps
CO
ONDUIT SIZE
E SYMBOLS
Ordering Sym
mbol 2 3 4 5 6 7
EX
XAMPLE: JC J Type Boxx to have 1-11/4” hubs
top/bottom
m and ¾” leftt side only with
w cable
support and threee (3) terminaal blocks.
O
ORDERED A Junctionn Box #JC50053C03B
AS:
Use:
U
C
Combining t
technology with
w ease-of--use, Hugheyy
& Phillips thhird-generation GPS unitt combines
f
flash synchroonization and day-night sensing, andd
c be installed with justt one plug-inn cable. Thiss eliminates the
can t need to mount
m a sepaarate GPS unnit,
a
antenna, juncction box annd wiring. Reeliable, glitchh-free operaation is assurred, using a crystal
c and the
5
50/60Hz powwer line as a zero-drift timming referennce if the sattellite signall is momentaarily lost. Annd two
d
different flassh modes aree provided: fixed
f 40FPM M or bit-switcch selectablee 24, 30, 40 or 60 FPM. The unit
e
easily mountts with four screws
s to anny surface, orr pole mounnt using the optional
o braccket. Installaation
interconnect cable with quick
q connecct plugs fromm GPS unit to t controller unit. LEDss indicate Poower,
S
Sync and GP PS Lock statu us. With ruggged metal weatherproof
w f and a batterry-free desiggn, Hughey &
P
Phillips GPS S unit will prrovide years of reliable service
s for yoour wind farrm.
S
Specification
ns:
Input Voltagee 100‐132VAC C 50/60Hz, 100W max. EExternal Dimeensions 6‐1/4" x 6‐1//4" x 4‐1/8"
Enclosure NEMA 4 Painted Aluminu um M
Mounting Dimmensions 5‐1/8" x 6‐3//4"
Operation Teemperature ‐40° to +55°° C (4) #8 Holes
Indicators Power (Greeen) O
Optional Mou nting 1‐1/4" to 2‐3
3/4" Pole
GPS Loack (YYellow) B
Bracket
SYNC (Flashing Red)
SYNC Outputt 15‐27VDC, 1 100mA, 3ms p pulse
SYNC Adjustmments Day: 40FPMM
Night: 24, 300, 40, 60 FPM
M
Backup SYNC C Internal Crystal Clock or
AC Line
P
Part Numbeers:
40002075-001 GPS
G SYNC Module 400002074-003 GPS Cable,
C 100’
*77-32599 Photocell,
P 1220V, 35-60 ft-cd
f 400002074-004 GPS Cable,
C 150’
400020744-001 GPS
G Cable, 25’ 400002074-005 GPS Cable,
C 350’
400020744-002 GPS
G Cable, 50’ 400002082-001 Pole Mounting
M Kiit
Use:
U
L
LSPD devicees are designned to protecct all the
T
TM
F
FlashGuard medium in ntensity stroobe lighting
s
systems. The LSPD prov vides both a grounding solution
s
a surge supppression fo
and or these instaallations. Thee LSPD
m
minimizes exxposure to liightning dam mage throughh tower
light wiring, a lightning path
p that is commonly
c
o
overlooked a communiccations sites. Without thee use of
at
a LSPD, the interconnectting cable beetween the strobe’s
s
f
flashhead and the power supply provvides a directt path
t can allow
that w damaging surges and transients
t too enter
t shelter. Sites
the S with LSSPDs installeed have provven
r
reliability. S
Sites with preevious lightnning problem ms have
r
recorded hunndreds of lightning strikees after LSPD D
installation, with
w no dam mage to the power supplyy or
c
communicati ion equipmeent.
IInstallation::
L
LSPD units are
a installed between thee flashhead and a the poweer
s
supply, providing protection for bothh the lightingg power suppply
a the teleccommunicatiions equipmeent installedd at the site.
and
T LSPD unnits are supp
The plied in a fibberglass NEM MA 4X outddoor
e
enclosure. T protectorrs should be mounted onn the tower
The
a
above the icee bridge, beffore the cable turns to ennter the sheltter.
T first leveel of protectiion forces anny induced voltage
The v on thhe
c
cable’s shieldd to tower grround. All lines
l then paass through a
s
surge suppreession devicee before conttinuing to thhe power
s
supply. Detaailed installattion instructiions are inclluded with each
u and shouuld be adherred to for opttimum proteection.
unit
Specification
S ns:
• Response
R Tim me: Less thhan 5µs.
• Current
C Witthstand: 40 kA per modde; IEEE
C
C62.41 8x20µµs short circcuit waveformm.
• Circuitry:
C The
T LSPD is series wiredd with
parallel protection. Robuust MOVs prrotect all
ciircuits. A laarge ground plane
p bondeed to a #2
coopper grounnd lug providdes a strong electrical/
e
m
mechanical discharge
d poiint.
SiteGuard® monitoring services hanndles all of thhe time depeendent monittoring tasks without requuiring
S
y
your interacttion: If a ligh
ht “burns outt”, Hughey & Phillips’s system doess the followiing:
• Dry contact
c outpu ut is read intto the SiteGuuard System
m
• SiteGGuard initiatees alarm calll over a GSM M wireless coonnection
• Alarm m received at a ProtectionN Net Networkk operationss center, withh operators providing
p aroound the
clockk, 365 days a year service
• ProteectionNet iniitiates an FA AA Notice to Airmen (NO OTAM) for any approprriate lightingg failure
• The client
c is notified of the faailure via tellephone, voicemail, pageer, fax or em
mail
• With the NOTAM M in place, you
y can now w work at youur own scheddule to repaiir the light ouutage
• If afteer 14 days we w have not heard
h from you,
y we will contact youu to determinne the status of your
towerr
• We will
w file the NOTAM
N exttension if necessary or we
w will removve the NOTA AM, with noo
additional work fromf you
Use:
U
T SiteGuaard WC-60 caan be used inn conjunctioon with the entire
The e line off Hughey & Phillips
P conttrollers
a power suupplies rangiing from ourr 9LC controollers to our most used FlashGuard
and F s
series strobe
c
controllers. The SiteGuaard WC-60 isi a very costt effective annd maintenaance free alarrming systemm that
w allow thhe flexibility needed to allarm the systems at site without
will w the worry of exppensive com mputer
b
based prograammed systeems that requuire costly uppgrades.
Features:
F
256-b bit AES Enccryption Intelligentt Supervisioon
Advaanced encryp ption standarrd used for Any messaage generated serves as a
securre communiccations. supervisionn message per optional 24 2 hour
Duall-Path Techn nology or 30 day intervals.
i Thhis feature efffectively
Uses GPRS (Gen neral Packet Radio limits requuired messagges to be sentt.
Serviice) as primaary digital ceellular path Six Input Zones
Z
and automatically
a y switches too SMS (Shorrt Digital proocessing for improved
i deetection
Messsage Service)) if GPRS iss unavailablee. and false alarm
a protecttion
Diagnostic LEDs Tamper Protected
P Ennclosure
Proviide signal strrength and status Built-in tammper sends a report wheen a
indications. tamper conndition is dettected and a restore
QOS S when clearred.
Qualiity of Servicce diagnosticcs via Built-in Poower Supplyy
AlarmmNet supply y vital inform
mation Onboard chharging circuuit design
including when a message waas received, accommoddates back-upp battery. Includes
batterry voltage, in
nput voltagee, signal primary poower and batttery superviision.
strenggth and message path. Back-Up Battery
B
Web--Based Prog gramming 6V 3.1Ah supplied
s to deliver
d up too 24
Allowws complete interactive programmin
p ng hours of standby operaation.
from AlarmNet Direct.
D
S
System com
mponents:
• Celluular transceiv
ver
• Plug in power paack
• Remoovable cellullar antenna
• 25’ cable for easee of mountinng
• All necessary wirring points
• Batteery backup
S
Specification
ns
Electrical
E
Inputt Operating Voltage:
V 10.5 – 14.3VDC C or 9 – 16.55VAC transfformer incluuded
Backkup Battery: 6V 3.1A (244hrs. standbyy)
Curreent Requirem
ments: 60mA A standby, 4000mA durinng transmissiion
Transsmission Powwer: 850MH Hz 1Watt, 1900MHz
1 2 Watts
W
Mechanical
M
Dimeensions: 8” H x 7.5” W x 1.86” D
Operating Tempeerature: -30°° to 60° C
Humiidity: 0% to 90% non-coondensing
U Listing
UL
UL 365 – Police Station Connnected Burgglar Alarms
UL 1610 – Centrral Station Buurglar Alarm
ms
UL 1625 Digital Alarm Com mmunicator Systems
S
UL 985
9 – Househhold Fire Waarning Systeems
O
ORDERING
G
OBM
MISC215 Digitall Cellular Coommunicatoor (SiteGuardd WC-60)
OBM
MISC236 GSM Antenna,
A outtdoor, GSM-ANT3DB, omni-directiional
SMIS
SC234 GSM Adapter
A Cabble, WA76266-CA SMA to
t N Adapteer
• No Monthly Fees
Sensaphone 800
Features Applications
When an alarm is detected, the 400 can notify four people Agriculture
by making voice phone calls. It will continue to make phone
calls until someone responds to the call. The 400 also in-
cludes nonvolatile memory and a 24-hour battery backup
with user-installed batteries.
Notes:
1. The overall height of the structure including all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels.
2. The red obstruction lighting system is composed of flashing omnidirectional beacons (L-864) and/or steady
burning (L-810) lights. When one or more levels is comprised of flashing beacon lighting, the lights should flash
simultaneously.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in
accordance with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 5, and 12.
Notes:
1. The height of the main structure excluding all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels. Note: Any appurtenances over 40 feet (12 meters) requires additional
lighting, consisting of a Medium Intensity L-865 White Strobe, see FAA Style C.
2. When high intensity white lights are operated 24 hours a day, other methods of marking and lighting may be
omitted. This system should not be recommended on structures 500 feet (153 meters) AGL or less unless an FAA
aeronautical study shows otherwise.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in
accordance with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 7, and 12.
Notes:
1. The height of the main structure excluding all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels. Note: Any appurtenances over 40 feet (12 meters) requires additional
lighting, consisting of a Medium Intensity L-865 White Strobe.
2. When high intensity white lights are operated 24 hours a day, other methods of marking and lighting may be
omitted. This system should not be recommended on structures 500 feet (153 meters) AGL or less unless an FAA
aeronautical study shows otherwise.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in
accordance with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 7, and 12.
Notes:
1. The overall height of the structure including all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels.
2. The medium intensity flashing white light system is normally composed of flashing omnidirectional lights. This
system is not normally recommended on structures less than 200 feet AGL.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in
accordance with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 6, and 12.
Notes:
1. The overall height of the structure including all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels.
2. The dual lighting system includes red lights (L-864) for nighttime and medium intensity flashing white lights (L-865)
for daytime and twilight use. This lighting system may be used in lieu of operating a medium intensity flashing white
lighting system at night. Some populated areas where the use of white medium intensity at night may cause
significant environmental concerns, the use of the dual lighting system should reduce/mitigate those concerns.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in accordance
with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 8, and 12.
Notes:
1. The height of the main structure excluding all appurtenances such as rods, antennas, obstruction lights, etc.,
determines the number of light levels. Note: Any appurtenances over 40 feet (12 meters) requires additional
lighting, consisting of a Medium Intensity L-865 White Strobe and a L-864 Red Beacon.
2. This dual lighting system includes red light (L-864) for nighttime and high intensity flashing lights (L-856) for
daytime and twilight use. This lighting system may be used in lieu of operating a high intensity flashing white
lighting system at night. There may be some populated areas where the use of high intensity lighting may cause
significant environmental concerns. The use of the dual lighting system should reduce/mitigate those concerns.
3. The chart above illustrates the requirements for standard lighting of towers and supporting structures in
accordance with FAA Advisory Circular 70/7460-1; Chapters 3, 4, 9, and 12.