You are on page 1of 6

S.

No Name of the Standards Units Technical Specifications


Equipment

1. Grammage Sample ISO 3801, ASTM Grammage Sample Cutter is


Cutter D3776 / 2646, BS used to quickly and precisely cut
(Hydraulic/automatic) 3424 / 2471 samples of standard area.
It is the special sample taker of
grammage measurement for
paper and cardboards.
Sample Area: 100cm²
Accuracy: ±0.35cm²
Sample Thickness: (0.1~1.0) mm
.
2. Tear Tester - Digital IS 1060; ISO Selectable • Purpose: To measure the force
Model 1974,6383-2, [Percentage required to propagate an
9290; ASTM (%), existing slit a fixed distance to
D295, D752, Millinewtons the edge of the test sample.
D1424, D1922, (mN), Grams- • 7” full-color digital touch
D5734 ASTM force (gf), screen display
D1922; TAPPI Pounds-force • Standard Impact Head:
T414, T496 (lbf)] • Radius: 0.5 inches (12.7 mm)
• Diameter: 0.75 inches (19.0
mm)
• O-Ring Clamp: Inside
Diameter: 89 mm
• Sample Size: 5 x 5 in (127 x
127 mm) square
• 5.25 in (133.35 mm) diameter
circle
• Air Clamp Assembly: Min. 60
PSI
• Pendulum: Universal with
interchangeable weights (200,
400, 800, 1600, 3200 and 6400
gram)
• Pneumatic clamps and
pendulum release
• Automatic calibration of
pendulum
• Sample statistics: Average,
High/low results, Standard
deviation
• Output: USB flash drive, USB
ESC/POS printer, RS232
• Power: Single phase; 220/240
V; 50/60 Hz
• Storage and editing of up to
200 readings
• Report printout with optional
printer
3. Puncture Resistance IS 4006 (Part-II), To measure Puncture Resistance
Tester (digital) IS 2771 (Part II), of various packaging materials
TAPPI T 803 om- like paper & corrugated
99 boards/boxes etc. Micro
Processor-based control panel;
digital display.
4. Moisture Content ISO 712:2009 Spectralab Volumetric Karl
Fischer Titrator has been
designed water ranging from
10 ppm to 100% of moisture
by Volumetric method.
Analysis of ppm level moisture
in hydrocarbon samples.

5. Ash Content ASTM D 5630, An Ash test is used to


D4218, D790, determine if a material is
D2974, D4218 filled. The Ash test result is
expressed as % ash. The
total ash content equals
the weight of the ash
divided by the weight of the
original sample multiplied
by 100%.
Size of muffle furnace : 4”
X 4” X 9” deep.
· Heating Load : 2 KW.
· Temperature Range :
Ambient to 1000°C.
· Temperature Controller :
Digital micro controller
· Resolution : 1°C &
Accuracy of ±1°C.
· Table Top Model
· Power Supply : 1 Phase,
230 VAC, 50 HZ
· Paint : Powder coating

6. Smoothness Tester IS 9894, TAPPI T- • Measuring range: 5-3000


(Porosity Tester) 251, ASTM D-737 ml/min
and ISO 5636/1 • Measuring accuracy: ± 0.5 % of
the final value
• Accuracy of test duration: ±
0.5 s
• Able to Calculate mean and
Standard deviation
automatically
• Should be able to measure the
porosity (or air-permeability) of
materials like non-woven or
woven textiles, filter and cloth
felts, some types of blotting,
saturating and absorbent bag
papers, meshes, etc.
• Calibration certificate from
NABL accredited laboratory
.Three years warranty plus five
years AMC after the warranty
period.
7. Brightness Test
TAPPI T 452 Brightness of pulp, paper, and
paperboard
(directional reflectance at 457 nm)

8. Gloss Meter for Paper TAPPI T -480, ISO Angle of Measurement : 20 Deg
and Paper Board at 75 8254, ASTM D & 75 Deg
deg & 20 Deg 523, ASTM D Measurement Range: 0-2000 GU
(Specular gloss of 2457, ASTM E (Gloss Units)
paper and paperboard 430, ISO 2813, Repeatability: 0.2 GU (Gloss
at 75 degrees) - ISO 13803, DIN Units)
Imported 67530. Reproducibility: 0.5 GU (Gloss
Units)
Measurement Range: 10-2500
HU (Haze Units)
Repeatability: 1 Hu (Haze Unit)
Reproducibility: 7 HU (Haze
Units)
Measurement Range - Ø Light
transmittance: 0 ~ 100%; Ø
Haze: 0-30% (absolute
measurement);
Ø Haze: 30.1% ~ 99% (relative
measurement)
Resolution: 0.1
Accuracy – light
transmittance:≤1;
Haze: ≤0.5%: ≤±0.3%
Repeatability - Light
transmittance: 0.5%;
Haze: ≤0.5%: 0.1% .
9. Bursting Strength ASTM D 3786 Range: Upto 60 kg/cm2 Least
Tester (digital) and IS 1060 Part Count: 0.01 kg/cm2
1 Clamp: Pneumatic
The diaphragm used in the
equipment should be 0.35-0.45
mm thick and the pressure
required to bulge the diaphragm
5 mm above the top plane of
the lower clamping surface of
the test instrument should not
be more than 0-0.7 kg/cm2.
10. Dennison Wax Pick-up IS 1060 (Part 3), Unitless. Apparatus should be comprised
Tester TAPPI T 459 of:
1. Heating device, such as:
Bunsen burner, alcohol lamp,
propane torch, or electric heat
element.
2. Wooden block, about 90 × 40
× 10 mm having a 30 mm
diameter hole with an edge
about 3 mm from one end.
3. Work surface that is smooth,
hard, and a poor conductor of
heat, such as wood.
11. Die Punch for Sample IS 1060, IS 2508, To obtain specimen by
Preparation (Tensile ASTM D 638, punching, using hollow dies of
Strength, Folding ASTM D 882 different sizes and contours.
Endurance etc.) Interchangeable socket punches
/Automatic Sample with different profiles and size
Cutter as per according to the customer
ISO/ASTM needs.
Should be made of steel with
hand finished cutting edges and
provided with ejector for easy
removal of the specimen after
punching.
12. Scuff Proofness Tester IS 4006 (Part 1) The scuff tester can be used in
Paper & Packaging industries to
evaluate color transfer from
printed or coated surfaces
during rubbing. It is designed
and produced according to
ASTM Standard and measures
the number of double strokes
required to cause Fuzz
(distortion of appearence) and
Peel (actual rupture of the
surface).
13. COBB Tester TAPPI T 441 Cobb Test describes a
procedure for determining the
quantity of water absorbed by
non-bibulous paper, paperboard,
and corrugated fiberboard in a
specified time under
standardized conditions.
It is based on studies by
Cobb and Lowe, Cobb and other
investigators. For testing
unsized and absorbent paper or
paperboard.
14. Opacity Tester TAPPI T 519 • Range : 0 - 99.9 % opaque.
• Direct display : % opaque.
• Paint : Powder coated.
• Power : 230 Volts, 50Hz, single
phase.
It is a measure of diffuse opacity
(paper backing) of white and
near-white papers, previously
known as “printing opacity.” The
method may be employed for
colored papers on condition that
their reflectance (paper backing) is
greater than 20% and their diffuse
opacity (paper backing) is greater
than 45%.

15. Folding Endurance TAPPI Method T Specimen Size: 15 x 150 mm


Tester (Schopper 511 and ASTM Counter: 0-999,999 Load
Type) D2176 Precision: ±0.5 Folding Angle:
135±0.5°, 90±0.5° Speed:
Variable - From 20 cpm to
175±10 cpm Width of folding
head: 19±1 mm Arc radius of
folding surface: 0.25±0.02 mm,
0.38±0.02 mm, 3.5±0.02 mm
Clamping thickness of folding
head: 0.25, 0.5, 0.75, 1.0,
1.25mm
16. Compression IS 4006-1 (1985) This method covers the
Resistance Test. measurement of the resistance
of paperboard to edgewise
compression. Corrugated and
solid fibreboard containers are
subjected to crushing forces in
shipment. This test is used for
two purposes in the evaluation
of the paperboard to be used as
components of such fibreboard
containers: (a) to indicate
edgewise rigidity of the board so
that manufacturing processes
may be controlled to secure the
desired results, and (b) to
indicate the probable crushing
resistance of the finished
container. This method is
intended only for paperboard
not exceeding 0.49 mm in
thickness.
17. Multimeter (Ph, Unitless.
Temperature and
Humidity)

You might also like