You are on page 1of 1

300 Results

C, kPa 13.9
f, deg 33.2
Tan(f) 0.65

200
Fail. Stress, kPa

100

0
0 100 200 300 400 500 600

Normal Stress, kPa

300
Sample No. 1 2 3
Water Content, % 21.6 18.4 22.4
250
Dry Density, kN/m3 12.52 12.11 11.35
Initial

Saturation, % 60.3 48.0 51.1


200 3
Void Ratio 0.8411 0.9026 1.0301
Shear Stress, kPa

Diameter, mm. 59.9 59.9 59.9


Height, mm. 27.2 27.2 27.2
150
Water Content, % N/A N/A N/A
Dry Density, kN/m3
At Test

100 Saturation, %
2 Void Ratio
Diameter, mm.
50 1
Height, mm.
Normal Stress, kPa 70.2 140.4 280.9
0 Fail. Stress, kPa 75.7 81.7 205.3
0 5 10 15 20 Strain, % 2.7 5.3 7.7
Strain, % Ult. Stress, kPa
Strain, %
Strain rate, mm./min. N/A N/A N/A

Sample Type: Client: FACULTAD DE INGENIERIA CIVIL


Description: ARENA BIEN GRADUADA
Project: CONSTRUCCION DE MUSEO DE TRES PLANTAS
LL= 20 PL= 5 PI= 20
Specific Gravity= 2.65
Remarks:
Proj. No.: 10 Date Sampled:
DIRECT SHEAR TEST REPORT

Figure MIRANDA
Tested By: UNI.MIRANDA COLQUE JUAN C Checked By: ING.RONALD SARDINAS C