You are on page 1of 6

Network Parameter 4/9/2021

Data Name : CC-Link


CC-Link Setting
[CC-Link Setting]

Connection Block Not Set

1
Network Parameter 4/9/2021
Data Name : CC-Link
CC-Link Setting
[CC-Link Setting]
Setting Contents
Special Function Block No. -
Type -
Master Station Data Link Type Start Parameter by BFM
Mode -
Total Module Connected -
Remote input(RX) -
Remote output(RY) -
Remote register(RWr) -
Remote register(RWw) -
Ver.2 Remote input(RX) -
Ver.2 Remote output(RY) -
Ver.2 Remote register(RWr) -
Ver.2 Remote register(RWw) -
Special relay(SB) -
Special register(SW) -
Retry Count -
Automatic Reconnection Station Count -
Standby Master Station No. -
PLC Down Select -
Scan Mode Setting -
Delay Time Setting -
Remote Device Station Initial Setting -
Interrupt Settings -

2
Program setting 4/9/2021
Data Name : Program setting

Execution type Program file name


[Title]
Execution Program MAIN

3
Ladder 4/9/2021
Data Name : MAIN

X000 K60 T1
0 T1 A/S 8
B/D 72
X001
Y000

T1
MOV T1 D0 A/S 8
B/D 72
D0
A/S 28
B/D 8
X001 K40 T2
13 T2 A/S 21
B/D 74
X002
Y001

T2
MOV T2 D1 A/S 21
B/D 74
D1
A/S 28
B/D 21
S0 S1 D0
26 ADD D0 D1 D3 A/S 28
B/D 8
D1
A/S 28
B/D 21
D3
A/S 41 58
B/D 28
X002 S0
35 SET S0 A/S 36 38 54
B/D 26 52 67
S0
38 STL S0 A/S 36 38 54
B/D 26 52 67
S1
39 RST S1 A/S 49 51 57
B/D 27 39 69
D3
SUB D3 K10 D3 A/S 41 58
B/D 28
D3
A/S 41 58
B/D 28

Y002

S1
SET S1 A/S 49 51 57
B/D 27 39 69
S1
51 STL S1 A/S 49 51 57
B/D 27 39 69
S0
52 RST S0 A/S 36 38 54
B/D 26 52 67
S0
SET S0 A/S 36 38 54
B/D 26 52 67

56 RET

4
Ladder 4/9/2021
Data Name : MAIN

S1 D3
57 CMP K10 D3 M0 A/S 41 58
B/D 28
M0
A/S 66
B/D 58
M0 S0
RST S0 A/S 36 38 54
B/D 26 52 67
S1
RST S1 A/S 49 51 57
B/D 27 39 69
T1
RST T1 A/S 8
B/D 72
T2
RST T2 A/S 21
B/D 74

76 END

5
Project Contents List 4/9/2021
Data Name : Project Contents List
Workspace Name :
Project Name : tanggiam
Title :

Data Name Last Change Title


Parameter 4/7/2021 10:51:30 PM
PLC Parameter 4/7/2021 10:51:30 PM
Network Parameter 4/7/2021 10:51:30 PM
CC-Link 4/7/2021 10:51:30 PM
Special Module(Intelligent Function Module) 4/7/2021 10:51:30 PM
Global Device Comment 4/7/2021 10:51:30 PM
Program Setting
Execution Program
MAIN 4/7/2021 10:51:30 PM
MAIN 4/8/2021 12:08:43 AM
POU
Program 4/7/2021 10:51:30 PM
MAIN 4/8/2021 12:08:43 AM
Local Device Comment
Device Memory 4/7/2021 10:51:31 PM
MAIN 4/7/2021 10:51:31 PM

You might also like