MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

G650’s INCLUDED IN ALL NEW CM3 (and above) CONFIGURATIONS:

G650
Media Gateways that can be used
with the S87XX Media Server for
S8710 MCC1 Gateway
Multi-Connect configurations
Media Server GMCC or MCC
Complex Media Gateways can be mixed
with S87XX Multi Connect

MCC1/SCC1/G650 Media Gateways


(Port Networks)
IPSI or non-IPSI connected
SCC1 Gateway

G700 Gateway G700 and G350 Media Gateways


non-IPSI connected Requires TN799DP and
TN2302 Media Processor and/or TN2602 (80 or
G350 Gateway 320 channel - CM3 Only) Media Resource Board
in MCC1 /SCC1 /G650

S8300LSP /G700 and S8300LSP /G350


S8300LSP /G700
Media Gateways non-IPSI connected
Media Gateway
Requires TN799DP and TN2302 Media Processo
and/or TN2602 (80 or 320 channel – CM3 Only
S8300LSP /G350 Media Resource Board
Media Gateway in MCC1 / SCC1 /G650

NOTE: THE MEDIA RESOURCE BOARD 80 IS NO LONGER SOLD SINCE THE SALES OF
CM4.0 WENT LIVE.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 1


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

Media Gateway Connectivity Drawings included in this document


Direct Connect via Fiber Optic Cable:
 S87XX Standard Duplex MCC1 / SCC1 / 650 Gateway
 S87XX High Reliability MCC1 / SCC1 / 650 Gateway
 S87XX Critical Reliability MCC1 / SCC1 / 650 Gateway
DS1C Connect T1/E1:
 S87XX Standard Duplex MCC1 / SCC1 / 650 Gateway
 S87XX High Reliability MCC1 / SCC1 / 650 Gateway
 S87XX Critical Reliability MCC1 / SCC1 / 650 Gateway
Center Stage Switch (CSS) with Switch Node Carrier:
 S87XX Standard Duplex MCC1 / SCC1 / 650 Gateway
 S87XX High Reliability MCC1 / SCC1 / 650 Gateway
 S87XX Critical Reliability MCC1 / SCC1 / 650 Gateway
Reference Tables:
 Control IPSI, Ethernet Switch, Material Codes and Descriptions

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 2


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX Standard Duplex


Fiber Direct Connect

Single-Mode
S8710 Server A S8710 Server B

Ethernet Switch

IPSI
9823A EI EI 9823A
TN2312
FIBER 9823B TN570 TN570 9823B FIBER
A
RUN 300A 300A RUN
Control
Multi-Mode or Multi-Mode or
Single-Mode EPN 1 Single-Mode
MCC1 / SCC1 / G650

EPN 2 EPN 3
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650
9823A EI A EI 9823A 9823A 9823A
EI A EI
9823B TN570 Control TN570 9823B 9823B 9823B
FIBER TN570 Control TN570
300A 300A 300A 300A
RUN
Multi-Mode or
Single-Mode

This diagram depicts a S87XX Standard Duplex system using fiber connectivity between 3 Port
Networks. The maximum number of Direct Connect Port Networks is three. In the case of a link
failure, the system will remain in service because there is a remaining route from the S87XX to the
disconnected EPN, through the other EPN’s. Remember that when a Lightguide Interface Unit (LIU)
is used to connect to an EPN at a remote location, you will need fibers in both equipment rooms.
EPN Port Network links can be a mixture of Multi-Mode Short Local (200ft.), Short Remote (4900ft.),
Long Remote (25000ft.), Single-Mode Fiber (21.7mi.) or DS1C connected.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 3


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX High Reliability


Fiber Direct Connect
Single-Mode
S8710 Server A S8710 Server B

Ethernet Switch A Ethernet Switch B

Required
IPSI Port Carrier B
TN2312
B for 2nd TN2312 IPSI
Port in High Reliability

EI IPSI EI
9823A TN570 TN2312 TN570 9823A
9823B A 9823B
FIBER 300A 300A FIBER
Control
RUN RUN
Multi-Mode or EPN 1 Multi-Mode or
Single-Mode MCC1 / SCC1 / G650 Single-Mode

EPN 2 EPN 3
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650

EI A EI EI A EI
9823A 9823A 9823A 9823A
9823B TN570 Control TN570 9823B 9823B TN570 Control TN570 9823B
300A 300A FIBER 300A 300A

RUN
Multi-Mode or
Single-Mode

This diagram depicts a S87XX High Reliability using fiber connectivity between 3 Port Networks. The
maximum number of Direct Connect Port Networks is three. In the case of a link failure, the system
will remain in service because there is a remaining route from the S87XX to the disconnected EPN,
through the other EPN’s. To support the 2nd TN2312 IPSI card, EPN 1 requires a “B” position Port
Carrier. Remember that when a Lightguide Interface Unit (LIU) is used to connect to an EPN at a
remote location, you will need fibers in both equipment rooms.
EPN Port Network links can be a mixture of Multi-Mode Short Local (200ft.), Short Remote (4900ft.),
Long Remote (25000ft.), Single-Mode Fiber (21.7mi.) or DS1C connected.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 4


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX Critical Reliability


Fiber Direct Connect
Single-Mode
S8710 Server A S8710 Server B

Ethernet Switch A Ethernet Switch B

IPSI
9823A EI EI 9823A
B
9823B TN570 TN570 9823B
300A Port 300A

EI IPSI EI
9823A A 9823A
FIBER 9823B TN570 TN570 9823B FIBER
300A Control 300A
RUN RUN
Multi-Mode or Multi-Mode or
Single-Mode EPN 1 Single-Mode
MCC1 / SCC1 / G650

EPN 2 EPN 3
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650

9823A EI B EI 9823A 9823A EI B EI 9823A


9823B TN570 Port TN570 9823B FIBER 9823B TN570 Port TN570 9823B
300A 300A 300A 300a
RUN
Multi-Mode or
Single-Mode EI A EI 9823A
9823A EI A EI 9823A 9823A
9823B TN570 Control TN570 9823B
9823B TN570 Control TN570 9823B 300A
300A 300A 300A

This diagram depicts a S87XX Critical Reliability using fiber connectivity between 3 Port Networks.
The maximum number of Direct Connect Port Networks is three. In the case of a link failures, the
system will remain in service because there is a remaining route from the S87XX to the disconnected
EPN, through the other EPN’s. Remember that when a Lightguide Interface Unit (LIU) is used to
connect to an EPN at a remote location, you will need fibers in both equipment rooms.
EPN Port Network links can be a mixture of Multi-Mode Short Local (200ft.), Short Remote (4900ft.),
Long Remote (25000ft.), Single-Mode Fiber (21.7mi.) or DS1C connected.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 5


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX Standard Duplex


DS1C Direct Connect

S8710 Server A Single-Mode S8710 Server B

Ethernet Switch

C.O. IPSI C.O.


C DS1C EI EI DS1C C
TN2312
S TN1654 TN570 TN570 TN1654 S
U A U
Control
1 to 4 1 to 4
EPN 1
MCC1 / SCC1 / G650

EPN 2 EPN 3
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650
C
EI EI C C C
S DS1C A DS1C DS1C EI A EI DS1C
U S C.O. S S
TN1654 TN570 Control TN570 TN1654 U U TN1654 TN570 Control TN570 TN1654 U
1 to 4 1 to 4 1 to 4 1 to 4

This diagram depicts a S87XX Standard Duplex system using TN1654 DS1C connectivity between 3
Port Networks. The maximum number of Direct Connect Port Networks is three. In the case of a link
failure, the system will remain in service because there is a remaining route from the S87XX to the
disconnected EPN, through the other EPN’s. The TN2312 IPSI is supported in CM3 “Remote” DS1C
connected EPN’s. EPN Port Network links can be a mixture of the DS1C connected and Fiber options.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 6


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX High Reliability


DS1C Direct Connect

Single-Mode
S8710 Server A S8710 Server B

Ethernet Switch A Ethernet Switch B

Required
Port Carrier B
IPSI for 2nd TN2312 IPSI
TN2312 in High Reliability
B
Port

C IPSI C
C.O. S DS1C EI EI DS1C S C.O.
TN2312
U TN1654 TN570 TN570 TN1654 U
A
1 to 4
Control 1 to 4

EPN 1
MCC1 / SCC1 / G650

EPN 2 EPN 3
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650

C C
C DS1C EI A EI C.O. DS1C EI A EI DS1C C
DS1C S S
S
TN1654 TN570 Control TN570 U U TN1654 TN570 Control TN570 TN1654 S
U TN1654 U
1 to 4 1 to 4
1 to 4
1 to 4

This diagram depicts a S87XX High Reliability system using TN1654 DS1C connectivity between 3
Port Networks. The maximum number of Direct Connect Port Networks is three. In the case of a link
failure, the system will remain in service because there is a remaining route from the S87XX to the
disconnected EPN, through the other EPN’s. To support the 2nd TN2312 IPSI card, EPN 1 requires a
“B” position Port Carrier. The TN2312 IPSI is supported in CM3 “Remote” DS1C connected EPN’s.
EPN Port Network links can be a mixture of the DS1C connected and Fiber options.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 7


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX Critical Reliability


DS1C Direct Connect

Single-Mode
S8710 Server A S8710 Server B

Ethernet Switch A Ethernet Switch B

IPSI
C EI TN2312 EI
S DS1C DS1C C
TN570 B TN570 S
U TN1654 TN1654
Port U
1 to 4
1 to 4

C IPSI C C.O.
S DS1C EI EI DS1C S
C.O. TN2312
U TN1654 TN570 TN570 TN1654 U
A
1 to 4
Control 1 to 4

EPN 1
MCC1 / SCC1 / G650

C B C C B C
S DS1C EI EI DS1C C.O. DS1C EI EI DS1C
S S S
U TN1654 TN570 Port TN1654 TN1654 TN570 Port TN1654
TN570 U U TN570 U
1 to 4
1 to 4
1 to 4 1 to 4

C A C C A C
DS1C EI EI DS1C DS1C EI EI DS1C S
S Cntrl S C.O. S Cntrl U
U TN1654 TN570 TN570 TN1654 U U TN1654 TN570 TN570 TN1654
1 to 4 1 to 4 1 to 4 1 to 4

EPN 2 EPN 3
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650

This diagram depicts a S87XX Critical Reliability system using TN1654 DS1C connectivity between 3
Port Networks. The maximum number of Direct Connect Port Networks is three. In the case of a link
failure, the system will remain in service because there is a remaining route from the S87XX to the
disconnected EPN’s, through the other EPN’s. The TN2312 IPSI is supported in CM3 “Remote” DS1C
connected EPN’s. EPN Port Network links can be a mixture of DS1C connected and Fiber options.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 8


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

Center Stage Switch (CSS) S87XX Standard Duplex


Single-Mode
S8710 Server A S8710 Server B

EPN 1 D E F I NI T Y 0 3 4
SD

C port
Ethernet Switch A
B port

A Control A
EPN 2
EPN 1 Control
SHORT IPSI IPSI IPSI
EI TN2312 Short EI TN2312 EI TN2312
D port
Local Local
9823A TN570 A TN570 A TN570 A
Control 9823A Control Control E SNC

EP N 3 EPN 2 EPN 1
MCC1 / SCC1 / G650 MCC1 / SCC1 / G650 MCC1 ONLY
CENTER STAGE
Metallic MCC1 ONLY
Center Stage Switch
60184013
Fiber SHORT SHORT Fiber Cable SNC E
Local Local 200ft
200ft 9823A 9823A

TN572
SNI SNI SNI SNI SNI SNI DS1C CLOCK
SNI
TN573 TN573 TN573 TN573 TN573 TN573 TN1654 IS
TN573
PROVIDED
WITH
SHORT LONG 300A SNC
SNC E Remote Remote Single
H600-348 WITH DS1C
CARRIER
9823A 9823B Mode

FIBER C C C C
FIBER FIBER CABLE S S S S
U U U U

LIU LIU
LIU
NOTE:
S8700 Standard Duplex FIBER RUN FIBER RUN SINGLE
6 EPN's Required 4900' 25,000' MODE CENTRAL
FIBER OFFICE
3 IPSI's for n+1 22 MILES
TN2312BP Reliability LIU LIU
LIU

*Co-Located EPN's 63300 FIBER


FIBER FIBER CABLE
are the best option
C C C C
S S S S
SHORT LONG 300A U U U U
Remote Remote Single
9823A 9823B Mode
E E E
EI EI EI H600-348 WITH DS1C
P P P
TN570 TN570 TN570 E
N N N EI
DS1C P
3 4 5 TN570
TN1654 N
6

This diagram depicts a Standard Duplex S87XX with 6 Port Networks using a Center Stage Switch for
EPN connectivity. S87XX Standard Duplex designs request N+1 IPSI connectivity, High and Critical
require N times 2 or N x 2. A single TN2312 IPSI can support up to 5 Port Networks. The
maximum number Port Networks per Switch Node Carrier is 16. This Switch Node Carrier (SNC)
shows a mixture of Fiber and DS1C options.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 9


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX High Reliability


Center Stage Switch (CSS)
Single Mode
S8710 Server A S8710 Server B EPN1
S D

DE FI NITY 034

C port
Ethernet Switch A Ethernet Switch B B port

A Control
EPN 2 EPN 1
IPSI IPSI
TN2312 TN2312 D port
B B
Port Port E SNC
SHORT IPSI IPSI
Local EI TN2312 EI TN2312
9823A TN570 A TN570 A
Control Control
Center Stage
Switch Node Carrier MCC1 Only
MCC1 / SCC1 / G650 Metallic SNC carrier E
60184013
Fiber Cable MCC1 ONLY
200ft
SNC Carrier E
TN572
CLOCK
SNI SNI SNI SNI SNI DS1C
SNI IS
TN573 TN573 TN573 TN573 TN573 TN1654
TN573 PROVIDED
WITH
SNC
SHORT SHORT LONG 300A CARRIER
H600-348 WITH DS1C
Local Remote Remote Single
9823A 9823A 9823B Mode

FIBER C C C C
FIBER FIBER CABLE S S S S
U U U U

LIU LIU
LIU

NOTE: FIBER RUN FIBER RUN


SINGLE
4900' 25,000' CENTRAL
High Reliability MODE OFFICE
6 EPN' Required FIBER
LIU LIU 22 MILES
4 IPSI's
63300 LIU
FIBER FIBER
FIBER C C C C
CABLE S S S S
U U U U
SHORT LONG
Remote Remote
9823B 300A
9823A
Single
Mode H600-348 WITH DS1C
E
EI E EI E EI
E DS1C P
TN570 P TN570 P EI TN570
P TN1654 N
N N TN570 N 6
3 4 5

This diagram depicts a High Reliability S87XX with 6 EPN Port Networks using a Center Stage Switch
for connectivity. The maximum number of Port Networks per Switch Node Carrier is 16. A single
TN2312 IPSI can support up to 5 Port Networks. This Switch Node Carrier (SNC) shows a mixture of
Fiber and DS1C options.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 10


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

S87XX Critical Reliability


Center Stage Switch (CSS)
S8710 A Single-Mode S8710 B EPN 1
S D

DE F I NITY 034

C Port
NOTE:
B Port
Critical Ethernet A Ethernet B
Reliability A Control
6 EPN's Require
IPSI IPSI IPSI IPSI
4 IPSI's TN2312 TN2312 TN2312 TN2312 D SNC
A B A B
Control Port Control Port E SNC
EPN 2 EPN 1 Center Stage
MCC1/ SCC1/G650 MCC1 ONLY MCC1

SNC E SNC D
SNI SNI
SNI SNI SNI SNI to EI SNI DS1C SNI SNI SNI SNI to EI SNI DS1C
TN573 TN573 TN573 TN573 SNI TN570 TN573 TN1654 TN573 TN573 TN573 TN573 SNI TN570 TN573 TN1654
TN573 TN573
H600-348 TN572 H600-348 TN5722
SHORT SHORT LONG 300A WITH DS1C CLOCKS SHORT SHORT LONG 300A WITH DS1C CLOCKS
Local Remote Remote Single ARE Local Remote Remote Single ARE
9823A 9823A 9823B Mode PROVIDED 9823A 9823A 9823B Mode PROVIDED
WITH THE WITH THE
SNC SNC
C C C C C C C C
CARRIERS. CARRIERS.
S S S S S S S S
FIBER U U U U FIBER U U U U
CABLE CABLE
FIBER FIBER FIBER
FIBER
FIBER FIBER
200' 200'
LIU LIU LIU LIU LIU
LIU

SINGLE SHORT SINGLE


SHORT
FIBER RUN FIBER RUN MODE CENTRAL Local FIBER RUN MODE
Local FIBER RUN CENTRAL
4900' 25,000' FIBER OFFICE 9823A 25,000' FIBER
9823A 4900' OFFICE
22 MILES 22 MILES
E
E EI
EI P
P TN570
N
TN570 N LIU LIU LIU LIU LIU LIU
2
2
C C C C C C C C
FIBER S S S S FIBER S S S S
CABLE U U U U CABLE U U U U
FIBER FIBER FIBER FIBER

H600-348 WITH DS1C H600-348 WITH DS1C


SHORT LONG 300A SHORT LONG 300A
Remote Remote Single E
E Remote Remote Single DS1C EI
9823A 9823B Mode DS1C EI P
P 9823A 9823B Mode TN1654 TN570
TN1654 TN570 N
N 6
6
E E E E E E
EI EI EI EI EI
P P P EI P
TN570 TN570 TN570 P P
N N N TN570 TN570 TN570
N N N
3 4 5 3 4 5

This diagram depicts a Critical Reliability 6 EPN Port Network S87XX using a Center Stage Switch for
connectivity. The maximum number of Port Networks per Switch Node Carrier is 16. A single
TN2312 IPSI can support up to 5 Port Networks. Each Switch Node Carrier (SNC) shows a mixture
of duplicate Fiber and DS1C options.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 11


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

Note: New Configurations now include TN2312BP IPSI’s in every G650 Port Network Carrier.
However, the Control IPSI rule from the table below still applies for S87XX Multi-Connect designs.
The IPSI is a combination of the former TN2182 Tone Clock and TN775 Maintenance Cards. S87XX
Multi-Connect can mix the G650 and MCC1/SCC1 Port Networks.

CONTROL IPSI TABLE

Number of Standard-Duplex High and Critical


Port Networks N+1 Nx1
1 - 5 2 1
6 - 10 3 2
11 - 15 4 3
16 - 20 5 4
21 - 25 6 5
26 - 30 7 6
31 - 35 8 7
36 – 40 9 8
41 – 45 10 9
46 - 50 11 10
51 - 55 12 11
56 - 60 13 12
61 - 64 14 13

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 12


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

MATERIAL CODE TABLES


Material Code DESCRIPTION
195250 TN2312BP (IP Server Interface) IPSI RHS
108469446 TN570DP EI (Expansion Interface)
107737934 TN573B SNI (Switch Node Interface)
108773912 TN771DP Facility Test Board (1 for each location recommended)
9823A Multi-Mode Fiber Transceiver
Short Range: 9823A - type transmit light up to 4,900 ft. (.93mi or 1.5 km)
109048
9823B Multi-Mode Fiber Transceiver
Long Range: 9823B-type (between 4,000 and 25,00 feet) (up to 4.73mi or 7.6km)
109042
300A Single-Mode Fiber Transceiver
300A transmit light up to 115,000 ft. (22mi or 35km)
109060
407439975 Multi-Mode Fiber 62.5 micron cable with ST /ST type connectors
Multi-Mode
Fiber ST CONN CABLE – 20 FT - SAP MATERIAL # 407439975
20 ft Default ST CONN CABLE – 30 FT - SAP MATERIAL # 407441435
*ADJUST ST CONN CABLE – 40 FT - SAP MATERIAL # 407441450
ASD
ST CONN CABLE – 50 FT - SAP MATERIAL # 407441468
Loc1>
ST CONN CABLE – 70 FT - SAP MATERIAL # 407441476
Target Adv>
ST CONN CABLE – 100 FT - SAP MATERIAL # 407441484
PN Separation

Careful !
Transceivers
Customer Provided when over 100-ft
Need ST type
connectors
Single-Mode Single-Mode Fiber 8.3 micron cable with ST / ST type connectors
Fiber
ST CONN CABLE – 20 FT - SAP MATERIAL # 407598325
ST CONN CABLE – 50 FT - SAP MATERIAL # 407598358

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 13


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

MATERIAL CODE TABLES


Material Code DESCRIPTION
188066 MCC1 AC Port Carrier Provides 20 universel slots.
VOL01 = Voltage 120 VAC w/ 20 Hz Ring Gen.
MCC1 AC
VOL03 = Voltage -48V DC w/ 20 Hz Ring Gen.
Port Carrier
MCC AC VOL06 = Voltage 208/240 VAC (4 wire) w/ 20 Hz Ring Gen.
VOL08 = Voltage -48V DC w/ 25 Hz Ring Gen.
VOL10 = Voltage -48 V DC wired 50 Hz Ring Gen.
179537 GMCC VOL38 = Voltage 200-240 VAC (4 wire) w/ 20 Hz Ring Gen.
VOL39 = International 20 Hz Ring Gen.
GMCC1 Port
VOL40 = International 25 Hz Ring Gen.
carrier
VOL41 = International 50 Hz Ring Gen.
700259724 G650 Media Gateway –come with single power supply 655A
700246671 G650 AC/DC Power Supply 655A (2nd G650 power supply for redundancy)
174297 SCC1 Port Carrier - Provides 18 universel slots.
VOL01 = Voltage 110VAC w/20 Hz Ring Gen. (Default)
SCC1
VOL03 = Voltage -48V DC w/20 Hz Ring Gen. with J58890CG DC Distribution Unit
Port Carrier
VOL04 = Voltage Int'l 200-240 VAC w/ 20 Hz Ring Gen.
VOL07 = Voltage Int'l 200-240 VAC w/ 25 Hz Ring Gen.
VOL09 = Voltage Int'l 200-240 VAC wired for 50 Hz Ring Gen.
VOL10 = Voltage -48V DC wired for 50 Hz Ring Gen.
VOL11 = Voltage -48V DC w/ 20 Hz Ring Gen. without DC Distribution Unit
179538 Switch Node Carrier
RLB10 = Standard Reliability (Default)
G/MCC
RLB11 = High Reliability
SNC RLB12 = Critical Reliability
Switch Node
SWC01 = Provides first Switch Node Clock (TN572) (Default)
Carrier
VOL01 = Voltage 120VAC w/ 20 Hz Ring Gen.
VOL03 = Voltage -48V DC w/ 20 Hz Ring Gen. (Provides new 649A Power Unit)
MCC AC VOL06 = Voltage 208/240 VAC (4 wire) w/ 20 Hz Ring Gen.
VOL06 = Voltage 208/240 VAC [4-wire] w/ 20 Hz Ring Gen. (Default)
VOL08 = Voltage -48V DC w/ 25 Hz Ring Gen.
VOL10 = Voltage -48V DC w/ 50 Hz Ring Gen.
VOL21 = Voltage -48V DC w/ 20 Hz Ring Gen. (Older 644A/645B Power Supply)
VOL22 = Voltage -48V DC w/ 25 Hz Ring Gen. (Older 644A/645B Power Supply)
VOL23 = Voltage -48V DC w/ 50 Hz Ring Gen. (Older 644A/645B Power Supply)
GMCC VOL38 = Voltage 200-240 VAC (4 wire) w/ 20 Hz Ring Gen.
VOL38 = Voltage 200-240 VAC (4 wire) w/ Domestic USA 20 Hz Ring Gen.
VOL39 = International 20 Hz Ring Gen.
VOL40 = International 25 Hz Ring Gen.
VOL41 = International 50 Hz Ring Gen.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 14


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

MATERIAL CODE TABLES


Material Code DESCRIPTION

179538 Switch Node Carrier ( position D )


VOL 48 for GMCC 200-240 VAC
G/MCC
VOL 03 for -48V DC
SNC VOL 06 for MCC AC 208/240 VAC
Switch Node VOL 39 International 20Hz Ring
Carrier VOL 40 International 25Hz Ring
VOL 41 International 50Hz Ring
179549 TN1654 DS1C - Supports from one to four T1 or E1 facilities. Select intra-cabinet
"Y" cable with "CBL", DS1 cable to extend from intra-cabinet "Y" cable to CSU with
(PEC 63565)
"CNN", and ship loose with "WSL": 847245750 (PEC 63566) = 14 inch Cable - In
DS1C Carrier (Used when DS1C will be placed in SNC next to SNI or in an EPN next to the
TN1654 EI Pack) (Default). Also includes: CNN33 = 50-ft DS1 Cable, Y Cable to CSU
(Default).
847245768 (PEC 63567) = 5 ½-ft Cable - Between Carrier (Used when DS1C is in
same cabinet but not same carrier as SNI)

179552 (PEC 63576) = 20-ft Cable - Between Cabinets (Used when DS1C is in
different cabinet than SNI)

631DA1 – 106432560 MCC Carrier Left Side


Power
631DB1 – 106432602 MCC Carrier Right Side
Supplies
649A – 107575565 GMCC Right Side
MCC
644A1 - 107575573 MCC DC Power Right Side

645B1 – 107575581 MCC DC Power Right Side


GMCC
655A – G650 Right or Left Side.
G650
Carrier Left Side Redundant Power must be added in ASD

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 15


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

When five G650s in a rack are connected together with TDM cables, the G650 in the bottom position
in the rack has a carrier address of A, and the G650 in the top position in the rack has a carrier
address of E. When the five G650s in a rack are not connected together with TDM cables, each G650
has a carrier address of A.
Multiple G650s can be rack mounted with some connected by TDM cables, and others not connected
by TDM cables. For example, a customer can request that the G650 in the bottom of the rack not be
connected to another G650. The carrier address of the G650 in the bottom of the rack is A. The
customer can request that the next two G650s in the rack be connected together by a TDM cable.
The carrier address of the lower of these two G650s is A, and the address of the upper G650 is B.
And the customer can request that two additional G650s be placed in the rack and be connected by
a TDM cable. The carrier address of the lower of these two G650s is A and the address of the upper
G650 is B. In this example, the rack has one G650 with an A carrier address, and two G650 stacks
with both an A and B carrier address.
The carrier address of an individual rack mounted, table mounted, or floor mounted G650 is A.
SOURCE: Hardware Guide for Avaya Communication Manager 555-245-207 pg. 129

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 16


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

Number Description
1&2 S87XX Servers
3 Ethernet switch
4&5 UPS units: one for each server
6 G650 Media Gateway: Carrier position “A”
7 G650 Media Gateway: Carrier position “B”
8 G650 Media Gateway: Carrier position “C”
9 G650 Media Gateway: Carrier position “D”
10 G650 Media Gateway: Carrier position “E”

SOURCE: Hardware Guide for Avaya Communication Manager 555-245-207 pg. 130

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 17


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

TN Circuit Packs Not Supported


by the G650 Enhanced Rack (as of 1-8-2007)

TN CP Num Description
TN1648 SYSTEM ACCESS - MAINTENANCE [Global]
TN1650 MEMORY 32MB [Global]
TN1655 PACKET INTERFACE [Global]
TN1657 DISK DRIVE [Global]
TN2135 ANALOG LINE (16) [Italy]
TN2146 DID TRUNK [Belgium]
TN2182 TONE - CLOCK [Global]
TN2184 DIOD TRUNK [Germany]
TN2200 EXCHANGE LINE [China]
TN2207 DS1 INTERFACE (24/32 CHANNEL) [Global]
TN2211 Optical Drive [Global]
TN2237 VIDEO PROCESSOR [Global]
TN2301 SURVIVABLE REMOTE [Global]
TN2314 DEFINITY One / IP600 Processor (RYON II)
TN2400 NET/PKT BACKPLANE CONNECTION [Global]
TN2401 NETWORK CONTROL / PACKET INTERFACE [Global]
TN2402 PROCESSOR [Global]
TN2404 PROCESSOR [Global]
TN420 TONE DETECTOR [Global except US]
TN437 4 WIRE E&M TIE TRUNK [Australia]
TN448 ANALOG LINE
TN555 DS1 PACKET ADJUNCT
TN570
EXPANSION INTERFACE [Global] (All circuit packs prior to
TN570B V7)
TN572 SWITCH NODE CLOCK [Global]
TN573 SWITCH NODE INTERFACE [Global]
TN573 SWITCH NODE INTERFACE [Global]
TN574 DS1 CONVERTER [Global]
TN577 PACKET GATEWAY [Global}
TN742 ANALOG LINE
TN748 TONE DETECTOR [Global]
TN756 TONE DETECTOR / GENERATOR [Global]
TN758 POOLED MODEM [Global]
TN762 HYBRID LINE (8) [Global]
TN765 PROCESSOR INTERFACE [Global]
TN767 DS1 INTERFACE [Global]
TN768 TONE - CLOCK [Global]
TN772 DUPLICATION INTERFACE [Global]
TN775 MAINTENANCE [Global]
TN776 EXPANSION INTERFACE [Global]
TN777 NETWORK CONTROL [Global]
TN778 PACKET CONTROL [Global]
TN780 TONE - CLOCK [Global]
TN782 MF TONE GENERATOR [United Stated]
TN786 PROCESSOR [Global]
TN787 MULTIMEDIA INTERFACE [Global]
TN788 VOICE CONDITIONER [Global]

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 18


Todd Young @2008 Avaya Inc. All Rights Reserved.
15-February-2008
MCC1, SCC1 and G650 Connection

Avaya S87XX Multi Connect MCC1, SCC1 and G650 Gateway

TN Circuit Packs Not Supported


by the G650 Enhanced Rack (as of 1-8-2007) Cont.

TN790 PROCESSOR [Global]


TN792 DUPLICATION INTERFACE [Global]
TN794 NETWORK CONTROL / PACKET INTERFACE [Global]
TN795 DEFINITY One / IP600 Processor (RYON)
TN796 PROCESSOR
TN798 PROCESSOR [Global]

Avaya and the Avaya Logo are trademarks of Avaya Inc. and may be registered in certain jurisdictions. All other trademarks
identified by ® and ™ are registered trademarks or trademarks, respectively, of Avaya Inc. All other trademarks are the
property of their respective owners.

Owner: Avaya Inc. – Proprietary – Use Pursuant to Company Instructions 19


Todd Young @2008 Avaya Inc. All Rights Reserved.

You might also like