CONFIDENTIALITY

THIS PLAN IS THE CONFIDENTIAL PROPERTY OF


KRUEGER INTERNATIONAL, INC. AND CONTAINS
INFORMATION THAT IS NOT TO BE USED EXCEPT IN
CONSIDERATION OF BIDS OR PROPOSALS
TENDERED HEREWITH. REPRODUCTION OR
COPYING OF THIS PLAN, IN WHOLE OR PART IS
PROHIBITED.

PURCHASER DOES NOT INTEND TO MAKE THIS


ANNEXATION A PERMANENT ACCESSION TO REAL
PROPERTY.

HARTZ MOUNTAIN INDUSTRIES INC CODE REQUIREMENTS


THIS PLAN IS BASED UPON KI'S INTERPRETATION OF
APPLICABLE SECTIONS OF THE 2018
INTERNATIONAL BUILDING CODE (IBC) AND
INFORMATION PROVIDED BY
OWNER/ARCHITECT/CONTRACTOR, WHICH
INFORMATION IS PRESUMED BY KI TO BE
ACCURATE WITHOUT INDEPENDENT
INVESTIGATION. NOTWITHSTANDING ANYTHING TO
THE CONTRARY NOW OR HEREAFTER STATED IN
ANY CONTRACT TO WHICH KI IS A PARTY, KI
DISCLAIMS ANY RESPONSIBILITY OR LIABILITY TO
INSURE THAT THIS PLAN COMPLIES WITH ANY
OTHER FEDERAL, STATE OR LOCAL STATUE,
REGULATION OR CODE SECTION APPLICABLE TO
THE PROJECT, PROJECT SITE, OR KI'S WORK,
REGARDLESS OF WHETHER KI MAY BE ADVISED OF

500 PLAZA DRIVE


THE SAME. APPROVAL OF THIS PLAN SHALL
INCLUDE AGREEMENT TO THE FOREGOING.
KI RECOMMENDS THAT THESE PLANS AND THE
RESULTING LAYOUTS BE REVIEWED WITH A LOCAL
FIRE INSPECTOR TO VERIFY COMPLIANCE WITH ALL
LOCAL BUILDING CODES. KI DISCLAIMS
RESPONSIBILITY FOR ANY SUCH REVIEW AND ANY
CLAIM OR LIABILITY THAT MAY RESULT FROM
NON-COMPLIANCE WITH LOCAL BUILDING CODES.

FIELD VERIFICATION
THIS PLAN INCORPORATES BUILDING INFORMATION
COMPILED FROM VARIOUS SOURCES ASSOCIATED
WITH THIS PROJECT AND DEEMED AS RELIABLE.
CONDITIONS DIRECTLY AFFECTING THE PRODUCT
OR IT'S INSTALLATION MUST BE FIELD VERIFIED.

SECAUCUS NJ 07094 PRODUCT NOTES


* ALL DIMENSIONS SHOWN ARE TO THE CENTERLINE
OF PANEL RUNS. ANY DIMENSIONS SHOWN FROM

KI OPPORTUNITY # 482328
DRYWALL BEGIN AT WALL STARTER. END OF RUN
CONDITIONS ARE DIMENSIONED TO END OF PANEL.

GENIUS:
* PANELS ARE STANDARD WITH 1" FURNITURE
SLOTTING. (SLOTTING NOT AVAILABLE IN GLASS
PANELS.
* PANEL THICKNESS= 3.5".
# Ind. Tag Quantity Part Number Description
* PANELS CANNOT ACCOMMODATE ELECTRICAL
New INFEEDS FROM CEILING IF INSTALLED DIRECTLY ON
1 UCON 7 UCON/102.000/4 UNIVERSAL CONNECTOR CEILING GRID.
2 SCON 18 ZG44635 UNIVERSAL CONNECTOR KIT CORNICE * 4"& 5" BASE ADJUSTABILITY: +/- 1"
3 MDF1/D1 9 ZG206740 (MDF FILLER) MDF FILLER * RECESSED BASE ADJUSTABILITY: +/- .5"
4 FMC4C2 2 ZG206741 (FMC/119.650/4/C2) FURNITURE MODULE CORNER POST * KI ASSEMBLES ALL COM AND STANDARD FABRIC
5 FMC4A1 3 ZG206742 (FMC/083.650/4/A1) FURNITURE MODULE CORNER POST WALL COVERINGS WITHIN THE GUIDELINES OF
6 FM24C2C2 2 ZG206746 (FM2/119.650/4/C2/C2) FURNITURE MODULE 2-WAY POST BIFMA INTERNATIONAL STANDARD FOR WOVEN
7 6 FHR/111.800/RAO FULL LENGTH RECESSED CONNECTOR TEXTILE CHARACTERISTICS (BIFMA TEX4. 102004)
8 27 FHR/079.900/RAO FULL LENGTH RECESSED CONNECTOR THE BOW AND SKEW TOLERANCE OF NO MORE
9 12 FHF/115.900/C2 FULL LENGTH FLUSH CONNECTOR THAN 1" ACROSS THE ROLL FOR 66" WIDTH FABRIC
10 2 FHF/115.900/A1 FULL LENGTH FLUSH CONNECTOR OR BELOW IS HELD.
11 20 FHF/102.000/C2 FULL LENGTH FLUSH CONNECTOR
12 25 FHF/102.000/A1 FULL LENGTH FLUSH CONNECTOR LIGHTLINE:
13 31 FHF/098.250/C2 FULL LENGTH FLUSH CONNECTOR * PANELS DO NOT SUPPORT HANG-ON FURNITURE
14 4 FHF/098.250/A1 FULL LENGTH FLUSH CONNECTOR (NO SLOTTING AVAILABLE).
15 37 FHF/084.000/C2 FULL LENGTH FLUSH CONNECTOR * PANEL THICKNESS = 2.25" AT CEILING TRIM, 2" AT
16 4 FHF/084.000/A1 FULL LENGTH FLUSH CONNECTOR BASE TRIM.
17 130 FHF/079.900/C2 FULL LENGTH FLUSH CONNECTOR * PANELS CANNOT ACCOMMODATE ANY
18 14 FHF/079.900/A1 FULL LENGTH FLUSH CONNECTOR ELECTRICAL.
19 BMEC2 8 BME/060.000/FH/C2 BUILDING MODULE END POST * PANEL ADJUSTABILITY:
20 BMEA1 4 BME/060.000/FH/A1 BUILDING MODULE END POST 2.5" BASE: + 0.25"
21 78.5BG3 1 ZG206736.07850 (TB/102.000/078.500/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED 3.25" BASE: + 1.00"
22 62.13BG3 2 ZG206736.06213 (TB/102.000/062.130/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED 4" BASE: + 1.75"
23 61.75BG3 2 ZG206736.06175 (TB/102.000/061.750/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
24 55.75T3 1 TF/102.000/055.750/R/4/A1/G1 THINLINE GLASS EVOKE:
25 48.5S23 1 ZG206726.04850 (GPE1/102.000/048.500/R/4/2/2G.43F/2G.41F/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT * PANELS DO NOT SUPPORT HANG-ON FURNITURE
26 48.5S21 1 ZG206855.04850 (Q11/102.000/048.500/R/4/WS/C2/C2) SOLID - SOLID PANEL (NO SLOTTING AVAILABLE).
27 47.88S13 1 ZG206871.04788 (Q11/083.650/047.880/C/4/WS/C2/C2) SOLID - SOLID PANEL * PANEL THICKNESS= 3.5".
28 47.88S11 1 ZG206870.04788 (GPE1/083.650/047.880/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT * PANELS CANNOT ACCOMMODATE ELECTRICAL
29 47.88S1 2 Q11/083.650/047.880/C/4/WS/C2/C2 SOLID - SOLID PANEL INFEEDS FROM CEILING IF INSTALLED DIRECTLY ON
30 46.38S27 1 ZG206861.04638 (GPE2/102.000/046.380/R/4/2/2G.43F/2G.41F/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ TWO ELECTRICAL HEIGHTS CEILING GRID.
31 46.38S26 1 ZG206857.04638 (GPE2/102.000/046.380/R/4/2/2G.43F/2G.43F/BOTH/WS/C2/C2) SOLID - SOLID PANEL W/ TWO ELECTRICAL HEIGHTS * 4" BASE ADJUSTABILITY: +/- 1"
32 46.38S25 1 ZG206856.04638 (Q11/102.000/046.380/R/4/WS/C2/C2) SOLID - SOLID PANEL
33 46.38S22 1 ZG206727.04638 (Q11/102.000/046.380/R/4/WS/C2/C2) SOLID - SOLID PANEL
34 46.38S17 1 ZG206723.04638 (GPE1/102.000/046.380/R/4/1/2G.43F/NONE/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT STRUCTURAL ANCHORAGE NOTES
35 46.38S16 3 Q11/102.000/046.380/R/4/WS/C2/C2 SOLID - SOLID PANEL
36 43.38S9 2 ZG206853.04338 (Q11/083.650/043.380/C/4/WS/C2/C2) SOLID - SOLID PANEL 1. ENGINEER OF RECORD (EOR) COULD BE THE
37 43.38S12 1 ZG206874.04338 (GPE1/083.650/043.380/C/4/2/2G.43F/2G.41F/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT ARCHITECT, FIRE MARSHAL (INSPECTOR), OR
38 42D3RHR 4 ZG206709.RHR (GLTS/102.000/042.000/R/4/SSP/RHR/LCR/GLAS/A1) LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR STRUCTURAL ENGINEER VIA THE CONTRACTOR. IT
39 42D3RHR 4 ZG206710.RHR (LLPGDS/041.250/096.750/G2/RHR) LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING IS NOT KI.
40 42.19S4 1 ZG206722.04219 (Q11/083.650/042.190/C/4/WS/C2/C2) SOLID - SOLID PANEL
41 42.19S3 1 ZG206868.04219 (GPE1/083.650/042.190/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
2. KI IS NOT RESPONSIBLE FOR THE CEILING
42 42.19S1 1 Q11/083.650/042.190/C/4/WS/C2/C2 SOLID - SOLID PANEL
SUPPORT GRID, PERIMETER WALLS, BULKHEADS,
43 41S9 3 ZG206853.04100 (Q11/083.650/041.000/C/4/WS/C2/C2) SOLID - SOLID PANEL
OR FLOOR STRUCTURE THAT SUPPORTS THE WALL
44 41S5 1 ZG206720.04100 (Q11/083.650/041.000/C/4/WS/C2/C2) SOLID - SOLID PANEL
SYSTEM.
45 41S2 3 ZG206717.04100 (GPE1/083.650/041.000/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
46 41S1 10 Q11/083.650/041.000/C/4/WS/C2/C2 SOLID - SOLID PANEL
3. VERIFY WITH (EOR) IF THE CEILING GRID IS
47 40.5S7 4 ZG206869.04050 (GPE1/083.650/040.500/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
ACCEPTABLE FOR USE BASED ON THE OCCUPANCY
48 40.5S5 2 ZG206720.04050 (Q11/083.650/040.500/C/4/WS/C2/C2) SOLID - SOLID PANEL
AND SEISMIC DESIGN CATEGORY. THE CEILING
49 40.5S1 6 Q11/083.650/040.500/C/4/WS/C2/C2 SOLID - SOLID PANEL
GRID CANNOT BE LOADED IN THE WEAK AXIS
50 40.25S8 5 ZG206719.04025 (GPE1/083.650/040.250/C/4/2/2G.43F/2G.41F/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
ORIENTATION UNLESS THE (EOR) PROVES
51 40.25S5 5 ZG206720.04025 (Q11/083.650/040.250/C/4/WS/C2/C2) SOLID - SOLID PANEL
OTHERWISE. DUE TO THE THIN GAUGE OF THE
52 40.25S2 6 ZG206717.04025 (GPE1/083.650/040.250/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
METAL, THE GRIDS ARE INTENDED TO BE LOADED IN
STRONG AXIS ORIENTATION ONLY. WEAK AXIS
53 40.25S1 12 Q11/083.650/040.250/C/4/WS/C2/C2 SOLID - SOLID PANEL
BENDING, TORSION, OR EVEN LARGE SHEAR
54 38.81S2 1 ZG206717.03881 (GPE1/083.650/038.810/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
FORCES MAY CAUSE THE CEILING GRID TO FAIL.
55 38.81S1 3 Q11/083.650/038.810/C/4/WS/C2/C2 SOLID - SOLID PANEL
WHILE THE GRID IS NOT THE RESPONSIBILITY OF KI,
56 38.13S6 1 ZG206852.03813 (GPE1/083.650/038.130/C/4/1/2G.43F/NONE/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
IT IS AN ISSUE THAT NEEDS TO BE ADDRESSED
57 38.13S15 1 ZG206873.03813 (Q11/083.650/038.130/C/4/WS/C2/C2) SOLID - SOLID PANEL
WITH THE (EOR) WHEN APPLICABLE.
58 38.13S11 1 ZG206870.03813 (GPE1/083.650/038.130/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
59 38.13S1 1 Q11/083.650/038.130/C/4/WS/C2/C2 SOLID - SOLID PANEL
4. METAL STUD ANCHORAGE OPTIONS AT THE
60 37S28 1 ZG206731.03700 (Q11/102.000/037.000/R/4/WS/C2/C2) SOLID - SOLID PANEL
CEILING MAY BE USED FOR IN-PLANE AND
61 37S19 1 ZG206730.03700 (Q11/102.000/037.000/R/4/WS/C2/C2) SOLID - SOLID PANEL
OUT-OF-PLANE BRACING. SEE SPECIFIC PRODUCT
62 37S18 1 ZG206729.03700 (Q11/102.000/037.000/R/4/WS/C2/C2) SOLID - SOLID PANEL
FOR WALL HEIGHT RESTRICITIONS. DO NOT USE
63 37S17 1 ZG206723.03700 (GPE1/102.000/037.000/R/4/1/2G.43F/NONE/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
CEILING GRID CLIPS IN CONJUNCTION WITH
64 37S16 1 Q11/102.000/037.000/R/4/WS/C2/C2 SOLID - SOLID PANEL
OUT-OF-PLANE METAL STUD ANCHORAGE.
65 37.81S14 1 ZG206872.03781 (Q11/083.650/037.810/C/4/WS/C2/C2) SOLID - SOLID PANEL
66 37.81S11 1 ZG206870.03781 (GPE1/083.650/037.810/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
5. ALL CONCRETE HAS BEEN ASSUMED TO BE
67 37.81S10 1 ZG206854.03781 (GPE1/083.650/037.810/C/4/1/2G.43F/NONE/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
NORMAL WEIGHT, UNCRACKED, AND HAVE A
68 37.81S1 1 Q11/083.650/037.810/C/4/WS/C2/C2 SOLID - SOLID PANEL
MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.
69 37.5S16 1 Q11/102.000/037.500/R/4/WS/C2/C2 SOLID - SOLID PANEL
70 35S24 1 ZG206724.03500 (Q11/102.000/035.000/R/4/WS/C2/C2) SOLID - SOLID PANEL
6. VERIFY WITH (EOR) IF CARPET GRIPPER SCREWS
71 35S21 1 ZG206855.03500 (Q11/102.000/035.000/R/4/WS/C2/C2) SOLID - SOLID PANEL
ARE ACCEPTABLE FOR USE BASED ON THE
72 35S20 1 ZG206728.03500 (Q11/102.000/035.000/R/4/WS/C2/C2) SOLID - SOLID PANEL
OCCUPANCY AND SEISMIC DESIGN CATEGORY.
73 35S16 1 Q11/102.000/035.000/R/4/WS/C2/C2 SOLID - SOLID PANEL
74 35.94S6 1 ZG206852.03594 (GPE1/083.650/035.940/C/4/1/2G.43F/NONE/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
7. IF SITE SPECIFIC CALCULATIONS ARE REQUIRED,
75 35.94S15 1 ZG206873.03594 (Q11/083.650/035.940/C/4/WS/C2/C2) SOLID - SOLID PANEL
ADDITIONAL INFORMATION SUCH AS THE SEISMIC
76 35.94S11 1 ZG206870.03594 (GPE1/083.650/035.940/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
COEFFICIENTS AND SPECIFIC BUILDING
77 35.94S1 1 Q11/083.650/035.940/C/4/WS/C2/C2 SOLID - SOLID PANEL
CONDITIONS WILL BE REQUIRED.
78 35.88S6 1 ZG206852.03588 (GPE1/083.650/035.880/C/4/1/2G.43F/NONE/SIDE A/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
79 35.88S15 1 ZG206873.03588 (Q11/083.650/035.880/C/4/WS/C2/C2) SOLID - SOLID PANEL
8. IF A PROFESSIONAL OR STRUCTURAL
80 35.88S11 1 ZG206870.03588 (GPE1/083.650/035.880/C/4/1/2G.43F/NONE/SIDE B/WS/C2/C2) SOLID - SOLID PANEL W/ ONE ELECTRICAL HEIGHT
ENGINEERING STAMP IS REQUIRED FOR THE SITE
81 35.88S1 1 Q11/083.650/035.880/C/4/WS/C2/C2 SOLID - SOLID PANEL
SPECIFIC LOCATION, THERE WILL BE ADDITIONAL
82 WP4C2C2 1 GWP4/102.000/C2/C2/C2 4" WALL POST
CHARGES FOR ENGINEERING.
83 WP2C2C2 5 GWP2/102.000/C2/C2/C2 2" WALL POST
84 WP2A1A1 4 GWP2/102.000/A1/A1/A1 2" WALL POST
85 10 12.0042.X SCREW #8X1/4" SL HEX WHD TAP
86 103 49.0015.A0 4" BASE COVER, ANODIZED
87
88
16
5
49.0104.P277
49.0122.A0
ASSEMBLY RECESS CEILING RAIL
CORNER COVER, 4" BASE ANODIZED
LEGEND
PANELS
89 38 49.0497.A0 EXTRUSION, CORNICE CAP, ANODIZED
90 5 49.0851.A0 CORNICE CAP 90 DEG ASM
INDICATES THE 'A SIDE'
91 8 49.1342 CHEESE BLOCK INSTALL TOOL
OF PANEL
92 12 49.1963 CEILING CHANNEL SPLICE 18GA
93 1 49.2040 DRILL GUIDE, CORNICE CAP END
94 40 50.1094 GASKET FM 3/16 X 3/4" X 30' VF5118 36S1
95 2 50.1498 3M SILANE GLASS TREATMENT
INDICATES THE SIZE
96 35 90.0505 HDW KIT 1/4" FINE LINE GRID
AND PANEL TYPE
97 396 90.3165 INSULATION FOR COVERS
98 52 CORNICECPLK.KIT CORNICE CAP LOCK COMPONENTS DOORS
99 48 CORNICESPLC.KIT CORNICE CAP SPLICE COMPONENTS
100 1 GW.INSTALL GENIUS INSTALL MANUALS/VERIFIED FIELD DIMENSIONS
DOOR NUMBER
101 4 HW.FORMSSURFACES~~PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR~~630 PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR 105
102 8 PANELTOOL.B PANEL INSTALLATION HOOK PTD
A
103 1 SLIDEWRENCH.BL GENIUS SLIDING DOOR WRENCH HARDWARE SET
104 1 SPRAYPAINT.P277 TOUCHUP SPRAYPAINT FOR POWDER PAINT
105 1 TOUCHUP.P550P TOUCHUP PEN FOR POWDER PAINT
FINISHES
Total New

STORE FRONTS
Total
C1 -POWDERCOAT W1 -WOOD
New
106 UCON 5 UCON/096.000/4 UNIVERSAL CONNECTOR
A1 -ANODIZED M1 -MARKERBOARD
107
108
UCON
SCON
10
6
UCON/102.000/4
ZG44635
UNIVERSAL CONNECTOR
UNIVERSAL CONNECTOR KIT CORNICE
F1 -FABRIC E1 -MARKERBOARD
109
110
FMC4A1
FMC4A1
8
2
ZG206742 (FMC/083.650/4/A1)
ZG206743 (FMC/119.650/4/A1)
FURNITURE MODULE CORNER POST
FURNITURE MODULE CORNER POST V1 -VINYL G1 -GLASS
111
112
FM34A1
FM3/90/135/A1
6
2
ZG206744 (FM3/083.650/4/A1)
ZG206745 (FM3/083.650/4/A1)
FURNITURE MODULE 3-WAY POST
FURNITURE MODULE 3-WAY POST J1 -INKJET
113 FM3/90/135/A1 1 ZG206748 (FM3/096.000/4/A1) FURNITURE MODULE 3-WAY POST
114 FM2FHA1A1 2 FM2/096.000/FH/A1/A1 FURNITURE MODULE 2-WAY POST RECONFIGURE
115 FM24A1A1 1 FM2/096.000/4/A1/A1 FURNITURE MODULE 2-WAY POST
'x' - PANEL SIZE TBD UPON VFD's
116 FM24A1A1 1 ZG206747 (FM2/119.650/4/A1/A1) FURNITURE MODULE 2-WAY POST
'e' - EXISTING PRODUCT
117 2 FHR/118.650/RAO FULL LENGTH RECESSED CONNECTOR
'i' - INVENTORY PRODUCT
118 1 FHR/096.000/RAO FULL LENGTH RECESSED CONNECTOR
119 1 FHR/092.250/RAO FULL LENGTH RECESSED CONNECTOR
LIGHTLINE
120 10 FHR/084.000/RAO FULL LENGTH RECESSED CONNECTOR
121 10 FHR/079.900/RAO FULL LENGTH RECESSED CONNECTOR 'T' - SHOWN IN LIGHTLINE CORNER CONDITIONS
122 2 FHF/118.650/A1 FULL LENGTH FLUSH CONNECTOR INDICATES DIRECTION OF GLASS OVERLAP
123 4 FHF/115.900/A1 FULL LENGTH FLUSH CONNECTOR
124 52 FHF/102.000/A1 FULL LENGTH FLUSH CONNECTOR ')))' - INDICATES STRUCTURAL SILICONE PANEL
125 20 FHF/098.250/A1 FULL LENGTH FLUSH CONNECTOR JOINT. ADD ADDITIONAL 1/8" TO PANEL
126 68 FHF/096.000/A1 FULL LENGTH FLUSH CONNECTOR OPENING WIDTH FOR EACH SYMBOL SHOWN.
127 13 FHF/092.250/A1 FULL LENGTH FLUSH CONNECTOR
128 65 FHF/084.000/A1 FULL LENGTH FLUSH CONNECTOR
129 10 FHF/079.900/A1 FULL LENGTH FLUSH CONNECTOR
130 BMEA1 2 BME/060.000/FH/A1 BUILDING MODULE END POST
131
132
133
92.5BG2
88.13BG1
87.63BG1
1
3
3
ZG206735.09250 (TB/096.000/092.500/R/4/A1/G1)
ZG206734.08813 (TB/083.650/088.130/C/4/A1/G1)
ZG206734.08763 (TB/083.650/087.630/C/4/A1/G1)
THINLINE GLASS, BUTT GLAZED
THINLINE GLASS, BUTT GLAZED
THINLINE GLASS, BUTT GLAZED
TYPICAL TYPICAL
134 81BG1 1 ZG206734.08100 (TB/083.650/081.000/C/4/A1/G1) THINLINE GLASS, BUTT GLAZED
135 81.13BG1 2 ZG206734.08113 (TB/083.650/081.130/C/4/A1/G1) THINLINE GLASS, BUTT GLAZED
136 80.25BG1 2 ZG206734.08025 (TB/083.650/080.250/C/4/A1/G1) THINLINE GLASS, BUTT GLAZED
137 79.5BG3 1 ZG206736.07950 (TB/102.000/079.500/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
138 77.38BG3 1 ZG206736.07738 (TB/102.000/077.380/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
139 75.75BG3 1 ZG206736.07575 (TB/102.000/075.750/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
140 74.76BG1 1 ZG206734.07476 (TB/083.650/074.760/C/4/A1/G1) THINLINE GLASS, BUTT GLAZED
141 74.76BG1 1 ZG206734.07476 (TB/083.650/074.760/C/4/A1/G1) THINLINE GLASS, BUTT GLAZED
142 74.5BG3 1 ZG206736.07450 (TB/102.000/074.500/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
143 74.13BG2 1 ZG206735.07413 (TB/096.000/074.130/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
144 72.5BG2 2 ZG206735.07250 (TB/096.000/072.500/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
145 71.75BG2 2 ZG206735.07175 (TB/096.000/071.750/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
146 67.13BG4 4 ZG206738.06713 (TB/096.000/067.130/R/4/A1/G4) THINLINE GLASS, BUTT GLAZED
147 65.75BG2 2 ZG206735.06575 (TB/096.000/065.750/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
148 63.25BG3 1 ZG206736.06325 (TB/102.000/063.250/R/4/A1/G1) THINLINE GLASS, BUTT GLAZED
149 60T1 1 TF/083.650/060.000/C/4/A1/G1 THINLINE GLASS
150 53.81T1 1 TF/083.650/053.810/C/4/A1/G1 THINLINE GLASS
151 52.5T1 1 TF/083.650/052.500/C/4/A1/G1 THINLINE GLASS
152 51.5T1 1 TF/083.650/051.500/C/4/A1/G1 THINLINE GLASS
153 51.25T2 1 TF/096.000/051.250/R/4/A1/G1 THINLINE GLASS
154 48.88T3 10 TF/102.000/048.880/R/4/A1/G1 THINLINE GLASS INSTALLATION PLAN
155 47.31T2 3 TF/096.000/047.310/R/4/A1/G1 THINLINE GLASS
156 45.5T2 1 TF/096.000/045.500/R/4/A1/G1 THINLINE GLASS
157 42D3RHR 4 ZG206709.RHR (GLTS/102.000/042.000/R/4/SSP/RHR/LCR/GLAS/A1) LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR
158
159
42D3RHR
42D3LHR
4
2
ZG206710.RHR (LLPGDS/041.250/096.750/G2/RHR)
ZG206709.LHR (GLTS/102.000/042.000/R/4/SSP/LHR/LCR/GLAS/A1)
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING
LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR TABLE OF CONTENTS
160 42D3LHR 2 ZG206710.LHR (LLPGDS/041.250/096.750/G2/LHR) LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING
161 42D2RHR 6 ZG206707.RHR (GLTS/096.000/042.000/R/4/SSP/RHR/LCR/GLAS/A1) LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR
162
163
164
42D2RHR
42D2LHR
42D2LHR
6
4
4
ZG206708.RHR (LLPGDS/041.250/090.750/G2/RHR)
ZG206707.LHR (GLTS/096.000/042.000/R/4/SSP/LHR/LCR/GLAS/A1)
ZG206708.LHR (LLPGDS/041.250/090.750/G2/LHR)
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING
LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING
SHEET 1/6:
165
166
42D1RHR
42D1RHR
4
4
ZG206705.RHR (GLTS/083.650/042.000/C/4/SSP/RHR/LCR/GLAS/A1)
ZG206706.RHR (LLPGDS/041.250/078.400/G2/RHR)
LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING
BILL OF MATERIALS
167
168
42D1LHR
42D1LHR
12
12
ZG206705.LHR (GLTS/083.650/042.000/C/4/SSP/LHR/LCR/GLAS/A1)
ZG206706.LHR (LLPGDS/041.250/078.400/G2/LHR)
LIGHTLINE STYLE THINLINE FRAMELESS GLASS SLIDING DOOR
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, SLIDING PANEL LEGEND
169 40.25T2 1 TF/096.000/040.250/R/4/A1/G1 THINLINE GLASS
170
171
38.91D6L
38.91D6L
1
1
ZG206715.LH (GLTP/096.000/038.910/R/4/DL/A1/CYL)
ZG206716.LH (LLPGDP/035.840/089.630/G3/DL)
LIGHTLINE STYLE THINLINE FRAMELESS GLASS PIVOT DOOR
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, PIVOT
PROJECT NOTES
172
173
38.91D5R
38.91D5R
2
2
ZG206713.RH (GLTP/102.000/038.910/R/4/DR/A1/CYL)
ZG206714.RH (LLPGDP/035.840/095.630/G2/DR)
LIGHTLINE STYLE THINLINE FRAMELESS GLASS PIVOT DOOR
LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, PIVOT RENDERINGS
174 38.91D5L 1 ZG206713.LH (GLTP/102.000/038.910/R/4/DL/A1/CYL) LIGHTLINE STYLE THINLINE FRAMELESS GLASS PIVOT DOOR
175 38.91D5L 1 ZG206714.LH (LLPGDP/035.840/095.630/G2/DL) LIGHTLINE STYLE FRAMELESS GLASS DOOR LEAF, PIVOT
PROJECT TITLE:
176 37.88T3 1 TF/102.000/037.880/R/4/A1/G1 THINLINE GLASS
HARTZ MOUNTAIN INDUSTRIES
177
178
3.5BME4A1
WP2A1A1
1
7
ZG206749 (3.5BME/96.00"/FH/A)
GWP2/102.000/A1/A1/A1
NON-STANDARD 3.5" END POST
2" WALL POST SHEET 2/6: INC
179 WP2A1A1 8 GWP2/096.000/A1/A1/A1 2" WALL POST
180
181
101BG3 2
20
ZG206736.10100 (TB/102.000/101.000/R/4/A1/G1)
12.0042.X
THINLINE GLASS, BUTT GLAZED
SCREW #8X1/4" SL HEX WHD TAP
PANEL KEY 500 PLAZA DRIVE

182
183
78
35
49.0015.A0
49.0104.P277
4" BASE COVER, ANODIZED
ASSEMBLY RECESS CEILING RAIL DETAILS SECAUCUS
NJ 07094
184 10 49.0122.A0 CORNER COVER, 4" BASE ANODIZED
185
186
1
19
49.0299.P277
49.0497.A0
END CAP RECESSED CEILING RAIL
EXTRUSION, CORNICE CAP, ANODIZED
DOOR SCHEDULE FLOOR/AREA:
187
188
1
10
49.0687.P277
49.0851.A0
ANGLED CEILING RAIL SPLICE
CORNICE CAP 90 DEG ASM LEGENDS 6TH FLOOR
189 8 49.1342 CHEESE BLOCK INSTALL TOOL
190 16 49.1747 CORNICE SLIDER REINFORCEMENT
REPRESENTATIVE:
191 21 49.1963 CEILING CHANNEL SPLICE 18GA GIGSTEAD, CHRISTINA
192
193
6
1
49.2034.A0
49.2040
3-WAY CORNICE CAP ASM ANODIZED
DRILL GUIDE, CORNICE CAP END SHEET 3/6: ORDER #:
194 80 50.1094 GASKET FM 3/16 X 3/4" X 30' VF5118
195
196
2
4
50.1498
90.0505
3M SILANE GLASS TREATMENT
HDW KIT 1/4" FINE LINE GRID
ELEVATIONS 203804, 203826
197 299 90.3165 INSULATION FOR COVERS
198 52 CORNICECPLK.KIT CORNICE CAP LOCK COMPONENTS
SALESFORCE #:
199 48 CORNICESPLC.KIT CORNICE CAP SPLICE COMPONENTS 482328
200
201
1
1
DOORTOOL.B
GW.INSTALL
DOOR INSTALLATION TOOL PTD
GENIUS INSTALL MANUALS/VERIFIED FIELD DIMENSIONS
SHEET 4/6:
DATE:
202
203
4
36
HW.IVES~~FS439~~US26D
HW.FORMSSURFACES~~PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR~~630
STOP FLOOR DOME IVES FS439 626
PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR FLOOR PLAN 08/06/2020
204 4 HW.IVES~~RL36~~US32D RL36 ROLLER LATCH
205 1 HW.SCHLAGE~~B560P X 12-288 X 10-094~~626 B560P X 12-288 X 10-094 DEADLOCK
206 8 PANELTOOL.B PANEL INSTALLATION HOOK PTD REVISIONS:
207
208
4
1
SLIDEWRENCH.BL
SPRAYPAINT.P277
GENIUS SLIDING DOOR WRENCH
TOUCHUP SPRAYPAINT FOR POWDER PAINT SHEET 5/6: N0. DATE BY DESCRIPTION

Total New 1 08/19/2020 MJS APPLY VFD'S/ INSTALL


Total STORE FRONTS ELECTRICAL PLAN 2 08/28/2020 MJS ELEVATION CHANGES

3 09/04/2020 MJS ELEC/ LOADBARS

4 09/10/2020 MJS REVISE SPECIALS


SHEET 6/6:
BILL OF MATERIALS TYPICAL TYPICAL CONNECTOR PLAN

DRAWN BY: SCALE:


MJS AS NOTED

DRAWING #:
D227361_NJ_06_L01_W_04.cmdrw
9/10/2020 8:15:27 AM

SHEET: COVER
1/6

V20.0
DRAWING REVIEW
THESE PLANS ARE INTENDED TO COMPLY WITH THE
KI DOOR SCHEDULE CONTRACT. AS SUCH, THESE PLANS MUST BE
HARDWARE SETS REVIEWED BY THE
A. B. C. D. OWNER/ARCHITECT/CONTRACTOR, OR OTHER
APPROPRIATE REPRESENTATIVE. IF KI IS TO
FRAME STYLE: GENIUS FRAMELESS GLASS CONTINUOUS HANGER SLIDING HARDWARE GENIUS BUTT HINGED GENIUS LIGHTLINE FRAMELESS GLASS PIVOT HUNG GENIUS LIGHTLINE FRAMELESS GLASS PIVOT HUNG PROCEED WITH PRODUCT INSTALLATION IN
HANDLE HARDWARE: FORMSSURFACES PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR, 42"CC, 48"OAL (QTY: 1) FORMSSURFACES PAIR-DT1214-48"CC,1-3/4"WD/AL DR, 42"CC, 48"OAL (QTY: 1) FORMSSURFACES PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR, 42"CC, 48"OAL (QTY: 1) FORMSSURFACES PAIR-DT1214-42"CC,48"OAL,BTB MNT,1/2" GLASS DR, 42"CC, 48"OAL (QTY: 1) ACCORDANCE WITH THESE PLANS, MARK THE
"APPROVED AS NOTED" BOX BELOW, EXECUTE AND
HANDLE FINISH: 630 630 630 630 COMPLETE THE INFORMATION AT THE BOTTOM OF
STRIKE HEIGHT: NON-LOCKING NON-LOCKING NON-LOCKING LOCKING
NON-LOCKING THIS PAGE, AND RETURN THIS DOCUMENT TO KI. IF
THESE PLANS ARE TO BE CORRECTED, MARK THE
DOOR STOP: SOFT STOP IVES FS439 (QTY: 1) IVES FS439 (QTY: 1) IVES FS439 (QTY: 1) "REVISE AND RESUBMIT" BOX BELOW, EXECUTE
LOCK: AND COMPLETE THE INFORMATION AT THE BOTTOM
OF THIS PAGE, AND RETURN THIS DOCUMENT TO KI.
MISC: IVES RL36 ROLLER LATCH (QTY: 1) IVES RL36 ROLLER LATCH (QTY: 1) SCHLAGE B560P X 12-288 X 10-094 DEADLOCK (QTY: 1) AUTHORIZED SIGNATURE INDICATED REVIEW OF
MISC: IVES RL36 ROLLER LATCH (QTY: 1) THESE PLANS. BELOW SIGNATURE, PRINT NAME,
TITLE, COMPANY OR AFFILIATION, AND DATE.
DOOR SCHEDULE MANUFACTURE OF PRODUCT SHOWN IS NOT
DOOR # ROOM # TAG HAND HARDWARE SET DOOR FRAME DOOR LEAF DOOR LEAF FINISH SCHEDULED UNTIL DRAWING REVIEW IS COMPLETE
AND AUTHORIZED SIGNATURE IS RECEIVED.
016 089 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED IT IS THE OWNER/ARCHITECT/CONTRACTOR'S
017 088 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED RESPONSIBILITY TO NOTIFY KI IF SITE CONDITIONS
HAVE CHANGED OR ARE NOT DEPICTED ON OUR
018 027 D5 RH C. GLTP - GENIUS FRAMELESS GLASS HINGE DOOR FRAMELESS GLASS DOOR 1/2 INCH CLEAR TEMPERED DRAWING THAT WOULD IMPACT OUR FURNITURE
019 027 D5 LH C. GLTP - GENIUS FRAMELESS GLASS HINGE DOOR FRAMELESS GLASS DOOR 1/2 INCH CLEAR TEMPERED LAYOUT AFTER COMPLETED FIELD VERIFIED
DIMENSIONS HAVE BEEN OBTAINED.
020 027 D5 RH C. GLTP - GENIUS FRAMELESS GLASS HINGE DOOR FRAMELESS GLASS DOOR 1/2 INCH CLEAR TEMPERED
021 028 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED APPROVED AS NOTED

022 029 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
REVISE AND RESUBMIT
023 030 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
SIGNATURE:
024 031 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
025 032 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED PRINT:
026 033 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
KI REP INITIALS:
027 034 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
DATE:
049 087 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
050 079 D1 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
APPROVAL STAMP
051 080 D1 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
052 081 D1 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
053 082 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
054 083 D1 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
055 084 D3 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
057 086 D3 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
058 036 D2 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
059 037 D2 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
063 040 D2 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
064 041 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
065 042 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
066 043 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
067 044 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
068 046 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
069 047 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
070 048 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
073 051 D3 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
075 052 D2 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
LEAF: ZG206710.LoR LEAF: ZG206714.LoR
LEAF: ZG206708.LoR FRAME: ZG206709.LoR FRAME: ZG206713.LoR LEAF: ZG206716.LoR 084 064 D6 LH D. GLTP - GENIUS FRAMELESS GLASS HINGE DOOR FRAMELESS GLASS DOOR 1/2 INCH VELOUR SATIN ETCH 1 SIDE

LEAF: ZG206706.LoR FRAME: ZG206707.LoR FRAME: ZG206715.LoR 088 069 D2 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
G2
G2 ZG206717.MOD ZG206868.MOD
FRAME: ZG206705.LoR G2 CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT 089 071 D2 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
CORNICE - NO CEILING ATTACHMENT G3 CORNICE - NO CEILING ATTACHMENT POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY
091 073 D1 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
C2 C2 C2 C2 C2
G2
GLASS HEIGHT 96.75"

GLASS HEIGHT 95.63"

GLASS HEIGHT 89.63"


093 075 D2 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
GLASS HEIGHT 90.75"

DOOR LEAF 98.07"

DOOR LEAF 97.46"


MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"


DOOR LEAF 91.46"
DOOR LEAF 92.07"

094 076 D2 LHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
GLASS HEIGHT 78.4"
DOOR LEAF 79.72"

095 077 D2 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED
102"

102"
96"

96"
096 078 D2 RHR A.-NO LOCK GLTS - GENIUS FRAMELESS GLASS SLIDING DOOR FRAMELESS GLASS DOOR - SOFT STOP 1/2 INCH CLEAR TEMPERED

79.9"

79.9"

79.9"
CL CL CL CL

84"

84"

84"
84"

THE SLIDING DOOR VALANCES ON KI ARCHITECTURAL WALLS THAT ARE INSTALLED BY A KI CONTRACTED INSTALLER (5" VALANCE, SOFT STOP AND BUMPER STOP) WILL BE
ALIGNED TO THE PANEL CONNECTION JOINT OF THE FURTHEST PANEL THAT THE SLIDING DOOR TRACK IS MOUNTED TO, NOT TO EXCEED 10' FROM THE FURTHEST PORTION OF
THE DOOR FRAME. IF A DIFFERENT VALANCE ALIGNMENT IS DESIRED, PLEASE CONSULT YOUR KI CERTIFIED INSTALLER

AFF 42"
AFF 42"

AFF 42"

AFF 42"

AFF 42"

6" 18"
1 1
ON KI ARCHITECTURAL WALLS INSTALLED UNDER CONTRACT THROUGH KI, PIVOT HINGE DOORS ARE SET TO SWING TO THE OPEN POSITION AS A DEFAULT. IF "NEUTRAL" OR "SWING CLOSED" ARE DESIRED, PLEASE CONSULT YOUR KI CERTIFIED INSTALLER.
KI OFFERS LOCK CYLINDERS AND CORES IN BOTH STANDARD AND INTERCHANGEABLE CORE (LFIC OR SFIC), BUT DUE TO CUSTOMER SECURITY CONCERNS, THE CORES WILL BE RANDOMLY KEYED ONLY.
P P ANY NON-STANDARD KEYING REQUIREMENTS, SUCH AS KEYED-ALIKE OR MASTER KEYED, ARE THE RESPONSIBILITY OF THE CUSTOMER OR CUSTOMER'S SECURITY AGENT.

18"

18"
SIDE A&B SIDE A&B SIDE A&B SIDE A&B SIDE A&B SIDE A&B SIDE A SIDE B SIDE A SIDE B
D1 D2 D3 D5 D6 S1 S2 S3
GENIUS PROJECT NOTES
ZG206722.MOD ZG206720.MOD ZG206852.MOD ZG206869.MOD ZG206719.MOD ZG206854.MOD ZG206870.MOD CARB COMPLIANT: NO
CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT ZG206853.MOD CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT
POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY CORNICE - NO CEILING ATTACHMENT POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY
CEILING HEIGHT: 84"
C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 96"

9"

9"

9"
102"
MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"


CEILING GRID TYPE: HDW KIT 1/4" FINE LINE GRID
CORNICE
DRYWALL ATTACHED CEILING RAIL
79.9"

79.9"

79.9"

79.9"

79.9"

79.9"

79.9"

79.9"
CL CL CL CL CL CL CL CL CL CL CL CL CL CL
84"

84"

84"

84"

84"

84"

84"

84"
CORNICE DECK HEIGHT: 102"

64.5"

64.5"

64.5"
FLOOR TYPE: TILE
6" 15"8" 6"13" 6" 6" 13"6" 6" 18"
1 2 D 2 D 1 1 1 D 1 1
SEISMIC KIT: NO

HANG ON COMPONENTS: NO
P PP D PP D P P P D P P
18"

18"
18"

18"
18"

18"

18"

18"
18"

18"

18"
OVERSEAS SHIPMENT: NO

SIDE A SIDE B SIDE A SIDE B SIDE A SIDE B SIDE A SIDE B SIDE A SIDE B INTERNAL FRAME SIDE A&B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B
S4 S5 S6 S7 S8 S9 S10 S11 GENIUS TRIM TYPES
4" BASE COVER A1 CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH

CORNICE CAP A1 CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH


ZG206723.MOD ZG206729.MOD ZG206730.MOD
GENIUS RECESSED CEILING RAIL C1 SILVER ANODIZED ALUMINUM
C2 C2 C2 C2 C2 C2 C2
ZG206874.MOD ZG206871.MOD ZG206872.MOD ZG206873.MOD
CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT DOOR AND GLAZING TRIM A1 CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY POWER ROUTED DOWN OR HORIZONTALLY
C2 C2 C2 C2 C2 C2 C2 C2
WALL POST BACK COLOR A1 CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
C2 SATIN SHEET TEXTURED
9"

9"

9"

9"
MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

GENIUS FLUSH CONNECTOR A1 CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH


C2 SATIN SHEET TEXTURED

98.25"

98.25"

98.25"

98.25"
102"

102"

102"

102"
CL CL CL CL CL CL GENIUS RECESSED CONNECTOR ANODIZED GRAY (RAO)
79.9"

79.9"

79.9"

79.9"

CL CL CL CL CL CL CL CL
84"

84"

84"

84"

NON-STANDARD OBJECT FINISH D1 DURATEK SATIN SHEET


64.5"

64.5"

64.5"

64.5"

13"6" 6"13" 7" 13"6" 6" 6" 6"13" 6" 6"13" FINISH SUMMARY
1 D 2 D 2 D 2 D 1 1 D 1 1 D 2
FINISH TYPE FINISH CODE
P D PP D PP D PP D P P D P P D PP ANODIZED
18"
18"

18"
18"

18"
18"

18"
18"

18"

18"

18"
18"

18"

18"
18"
A1 CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH AL-AO

INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B SIDE A&B SIDE A SIDE B SIDE A SIDE B SIDE A SIDE B DURATEK
S12 S13 S14 S15 S16 S17 S18 S19 D1 DURATEK SATIN SHEET FS-1353

FILM PATTERN
FM1 3M DUSTED CRYSTAL 7725-314
ZG206728.MOD ZG206855.MOD ZG206727.MOD ZG206726.MOD ZG206724.MOD ZG206856.MOD ZG206857.MOD ZG206861.MOD
C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 GLASS (TEXTURE TO INSIDE IF APPLICABLE)
G1 3/8 INCH CLEAR TEMPERED GLS
G2 1/2 INCH CLEAR TEMPERED GLT
G3 1/2 INCH VELOUR SATIN ETCH 1 SIDE GMD

3"

3"
9"

9"

9"

9"

9"

9"
6" 6"
GLASS
G4 *3/8 INCH VELOUR SATINETCH 1 SIDE VSE
PT TV
98.25"

98.25"

98.25"

98.25"

98.25"

98.25"

98.25"

98.25"
3"

3"
102"

102"

102"

102"

102"

102"

102"

102"
CL CL CL CL CL CL CL CL CL CL P CL CL CL P CL
POWDERCOAT
C1 SILVER ANODIZED ALUMINUM P277
C2 SATIN SHEET TEXTURED P550

70"

70"
64.5"

64.5"

64.5"

64.5"

64.5"

64.5"

60"

60"
6" 13"6" 18"
11" 6"13" 6"13" 25"
18" 6" 6"
FILM SQUARE FOOTAGE LEGEND

50"

50"
1 2 D D 2 1 D D 2 1 D 1 1 1

GENIUS
P PP D D PP P D D PP P D P P P
TOTAL 132'0.22"
18"

18"
18"

18"
18"

18"
18"

18"
18"

18"
18"

18"

18"

18"
FM1 3M DUSTED CRYSTAL 132'0.22"

INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A&B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B INTERNAL FRAME SIDE A SIDE B GENIUS ELECTRICAL LEGEND
S20 S21 S22 S23 S24 S25 S26 S27
CONVENTIONAL ELECTRICAL LISTED TOP TO BOTTOM IS LEFT TO RIGHT IN PANEL
SYMBOL QTY LOCATION BOX SIZE FEED PREWIRED GANG CIRCUIT# DEVICE COLOR FACEPLATE COLOR TYPE CONDUIT LENGTH CONDUIT
ZG206731.MOD ZG206736.MOD BOTTOM NO N/A BY OTHERS ELECTRICAL 3/4" FLEX
18 SHELL 4X4 DOUBLE BOTTOM NO 2 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX
C2 C2 G1
ZG206735.MOD G1 G1
ZG206738.MOD 2
G1 ZG206734.MOD G1 G1 G4 G4
CORNICE - NO CEILING ATTACHMENT CORNICE - NO CEILING ATTACHMENT BOTTOM NO N/A BY OTHERS ELECTRICAL 3/4" FLEX
1 SHELL 4X4 DOUBLE BOTTOM NO 2 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX
G1 G1 G1 PT-1
3"

MFG. CLG. HGT. 83.65"

MFG. CLG. HGT. 83.65"

3.5" 3.5"

PT-1 TV-1

42 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX
1
98.25"

98.25"

93.25"

98.25"

93.25"
3"
102"

102"

102"

CL P PC
92.25"

87.25"

92.25"

87.25"

92.25"

87.25"

LD
96"

96"

96"
79.9"

74.9"

79.9"

74.9"
84"

84"

27 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS DATA INCLUDED 1" FLEX
D
70"

60"

60"
50"

1 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX
PT

1 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS DATA INCLUDED 1" FLEX
TV-1
INTERNAL FRAME SIDE A SIDE B SIDE A&B SIDE A&B SIDE A&B SIDE A&B SIDE A&B SIDE A&B SIDE A&B
S28 T1 T2 T3 BG1 BG2 BG3 BG4
1 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 1" FLEX
TV

PANEL KEY Scale1/4" = 1'


FLEXIBLE CONDUIT TO EXTEND 2' OUT OF THE BOTTOM FRAMEWORK OF THE PANEL
EMT CONDUIT TO EXTEND 1" OUT OF THE BOTTOM FRAMEWORK OF THE PANEL
ALL ADDITIONAL ELECTRICAL COMPONENTS TO BE SUPPLIED BY OTHERS
2 PIECES OF CONDUIT MAXIMUM CAN BE ROUTED THROUGH THE BASE AND UP THROUGH A POST AND CEILING RAIL
POSTS AT FLOOR MAY NEED TO BE CUT FOR CONDUIT ACCESS

LINEAL FOOTAGE LEGEND


GENIUS
TOTAL 845'3.93"
NEW 845'3.93"

OUT OF PLANE BRACE


#10-12 SCREW @ 12" O.C. MAX. SPACING INTERNAL KI USE ONLY
#12-14 SCREW @ 16" O.C. MAX. SPACING
1/4"-14 SCREW @ 18" O.C. MAX. SPACING
(FY = 57 KSI) 08/17/2020 FINISH APPROVAL
O.C. SPACING MAY BE DOUBLED WHEN USING (2) FASTENERS 09/04/2020 DRAWING APPROVAL
2" APART. DO NOT EXCEED 24" O.C. SPACING.
(NOT INCLUDED) 08/17/2020 VFDs / HOLD DIMS
METAL STUD 08/24/2020 AUDIT COMPLETE
20 GA. MIN
YIELD STRENGTH 33 KSI
3.5" DRYWALL 3.5"
INSTALLATION PLAN
5/8" THICK MAX

3.5"
1.35"

CONCRETE SLAB: CONCRETE SLAB:


F'c = 3,000 PSI
2.5"

(2) 1/4" HILTI (2) 1/4" HILTI F'c = 3,000 PSI


KWIK HUS-EZ CRACKED N.W. MINIMUM CRACKED N.W. MINIMUM
WITH 1-5/8" EMB. MINIMUM THICKNESS DEPENDANT ON ANCHOR KWIK HUS-EZ
1.75" WITH 1-5/8" EMB. MINIMUM THICKNESS DEPENDANT ON ANCHOR
OR
5.25"

1.88" MIN 1.88" MIN ANCHORED DIAGONAL


2.5"

2.88" MAX 2.88" MAX ANCHORED DIAGONAL OR

1"
IN EACH PANEL CONCRETE OVER 20 GA. MIN. STEEL DECKING: IN EACH PANEL CONCRETE OVER 20 GA. MIN. STEEL DECKING:
(1) EACH END F'c = 3,000 PSI
4"

(1) EACH END F'c = 3,000 PSI

4"
(NOT INCLUDED)
2.75"

CRACKED N.W. OR L.W. (NOT INCLUDED) CRACKED N.W. OR L.W.

2.75"
MINIMUM THICKNESS DEPENDANT ON ANCHOR MINIMUM THICKNESS DEPENDANT ON ANCHOR
3.5"

3.5"

3.5" 3.5" PROJECT TITLE:


HARTZ MOUNTAIN INDUSTRIES
1 2 3 4 5 6 7 8 9 10 11 12 INC
500 PLAZA DRIVE
OUT OF PLANE BRACE
SECAUCUS
#10-12 SCREW @ 12" O.C. MAX. SPACING NJ 07094
#12-14 SCREW @ 16" O.C. MAX. SPACING
1/4"-14 SCREW @ 18" O.C. MAX. SPACING
OUT OF PLANE BRACE (FY = 57 KSI) FLOOR/AREA:
OUT OF PLANE BRACE O.C. SPACING MAY BE DOUBLED WHEN USING (2) FASTENERS
#10-12 SCREW @ 12" O.C. MAX. SPACING 2" APART. DO NOT EXCEED 24" O.C. SPACING. 6TH FLOOR
#10-12 SCREW @ 12" O.C. MAX. SPACING #12-14 SCREW @ 16" O.C. MAX. SPACING (NOT INCLUDED)
#12-14 SCREW @ 16" O.C. MAX. SPACING 1/4"-14 SCREW @ 18" O.C. MAX. SPACING REPRESENTATIVE:
1/4"-14 SCREW @ 18" O.C. MAX. SPACING (FY = 57 KSI) METAL STUD
(FY = 57 KSI) O.C. SPACING MAY BE DOUBLED WHEN USING (2) FASTENERS 20 GA. MIN GIGSTEAD, CHRISTINA
O.C. SPACING MAY BE DOUBLED WHEN USING (2) FASTENERS 2" APART. DO NOT EXCEED 24" O.C. SPACING. YIELD STRENGTH 33 KSI
2" APART. DO NOT EXCEED 24" O.C. SPACING. (NOT INCLUDED)
(NOT INCLUDED) DRYWALL ORDER #:
METAL STUD 5/8" THICK MAX
20 GA. MIN 203804, 203826
METAL STUD YIELD STRENGTH 33 KSI
20 GA. MIN
YIELD STRENGTH 33 KSI DRYWALL
SALESFORCE #:
DRYWALL 5/8" THICK MAX 482328
5/8" THICK MAX OUT OF PLANE BRACE
SEE PROJECT DATE:
1.75" SUMMARY FOR ANCHORING 08/06/2020
3.5" REQUIREMENTS
1"

1/4" FINELINE CEILING GRID REVISIONS:


1.35"

2.5"

(SHIPPED BY KI)
3.5" 0.5" 1.75" N0. DATE BY DESCRIPTION
1.75" 3.5" 1.75"
1"

1 08/19/2020 MJS APPLY VFD'S/ INSTALL


1.35"

1"

1"
2.5"

2.5"

2 08/28/2020 MJS ELEVATION CHANGES


2.5"

2.5"

3 09/04/2020 MJS ELEC/ LOADBARS


4.62"
3.41"

4 09/10/2020 MJS REVISE SPECIALS


3.45"

1.64" 1.64"
0.5"

3.5" 3.5"

3.5" 3.5" 0.5" 0.5" 3.5" 3.5" 3.5"


DRAWN BY: SCALE:
MJS AS NOTED
13 14 15 16 17 18 19 20 21
DRAWING #:
D227361_NJ_06_L01_W_04.cmdrw
DETAILS Scale3" = 1' 9/10/2020 8:15:28 AM

SHEET: LEGENDS
2/6

V20.0

FIELD VERIFIED DIMENSIONS


DRAWING REVIEW
THESE PLANS ARE INTENDED TO COMPLY WITH THE
CONTRACT. AS SUCH, THESE PLANS MUST BE
REVIEWED BY THE
OWNER/ARCHITECT/CONTRACTOR, OR OTHER
APPROPRIATE REPRESENTATIVE. IF KI IS TO
PROCEED WITH PRODUCT INSTALLATION IN
ACCORDANCE WITH THESE PLANS, MARK THE
"APPROVED AS NOTED" BOX BELOW, EXECUTE AND
COMPLETE THE INFORMATION AT THE BOTTOM OF
THIS PAGE, AND RETURN THIS DOCUMENT TO KI. IF
THESE PLANS ARE TO BE CORRECTED, MARK THE
"REVISE AND RESUBMIT" BOX BELOW, EXECUTE
AND COMPLETE THE INFORMATION AT THE BOTTOM
OF THIS PAGE, AND RETURN THIS DOCUMENT TO KI.
AUTHORIZED SIGNATURE INDICATED REVIEW OF
THESE PLANS. BELOW SIGNATURE, PRINT NAME,
TITLE, COMPANY OR AFFILIATION, AND DATE.
MANUFACTURE OF PRODUCT SHOWN IS NOT
SCHEDULED UNTIL DRAWING REVIEW IS COMPLETE
AND AUTHORIZED SIGNATURE IS RECEIVED.
IT IS THE OWNER/ARCHITECT/CONTRACTOR'S
RESPONSIBILITY TO NOTIFY KI IF SITE CONDITIONS
HAVE CHANGED OR ARE NOT DEPICTED ON OUR
DRAWING THAT WOULD IMPACT OUR FURNITURE
LAYOUT AFTER COMPLETED FIELD VERIFIED
DIMENSIONS HAVE BEEN OBTAINED.

APPROVED AS NOTED

REVISE AND RESUBMIT

SIGNATURE:

PRINT:

KI REP INITIALS:

DATE:

APPROVAL STAMP

14 17 20
2/6
2/6 2/6
9 15
67.13" 67.13" 38.91" 67.13" 67.13" 47.31" 47.31" 47.31" 42" 42" 45.5" 2/6 72.5" 42" 74.13" 42" 42" 72.5" 42" 51.25" 2/6

G4 G4 G4 G4 G3 G4 G4 G4 G4 74.76" 74.76" 42" 42" 81.13" 42" 81.13" 81" 42" 80.25" 42" 80.25" 42"

BG4 BG4 D6 BG4 BG4 T2 T2 T2 D2 D2 T2 BG1 BG1 D1 BG2 D2 BG2 D2 D2 BG2 D2 T2 D1 BG1 D1 BG1 BG1 D1 BG1 D1 BG1 D1

16
10
ELEVATION A 2/6 ELEVATION B ELEVATION C ELEVATION D ELEVATION E ELEVATION F ELEVATION G ELEVATION H 2/6
ELEVATION I
18
2/6

63.25" 42" 101" 101" 42" 37.88" 48.88" 48.88" 48.88" 48.88" 48.88" 38.91" 38.91" 48.88" 48.88" 48.88" 48.88" 48.88" 38.91"
71.75" 71.75" 42" 42" 65.75" 65.75"

88.13" 42" 88.13" 42"


INTERNAL KI USE ONLY
08/17/2020 FINISH APPROVAL
4"

09/04/2020 DRAWING APPROVAL


08/17/2020 VFDs / HOLD DIMS
23"

08/24/2020 AUDIT COMPLETE


4"

INSTALLATION PLAN
30"

BG3 D3 BG3 BG3 D3 T3 T3 T3 T3 T3 T3 D5 D5 T3 T3 T3 T3 T3 D5 BG2 BG2 D2 D2 BG2 BG2 BG1 D1 BG1 D1


19
2/6
ELEVATION J ELEVATION K ELEVATION L ELEVATION M ELEVATION N

42" 74.5" 42" 77.38" 42" 79.5" 42" 75.75" 42" 62.13" 62.13" 42" 78.5" 42" 55.75"
42" 40.25" 42" 92.5"

60" 42" 87.63" 42" 87.63" 42" 87.63" 42" 88.13" 42"

PROJECT TITLE:
HARTZ MOUNTAIN INDUSTRIES
INC
500 PLAZA DRIVE

SECAUCUS
NJ 07094

FLOOR/AREA:
6TH FLOOR
T1 D1 BG1 D1 BG1 D1 BG1 D1 BG1 D1 D2 T2 D3 BG3 D3 BG3 D3 BG3 D3 BG3 D3 BG3 BG3 D3 BG3 D3 T3 D2 BG2
REPRESENTATIVE:
GIGSTEAD, CHRISTINA
ELEVATION O ELEVATION P ELEVATION Q ELEVATION R ELEVATION S ELEVATION T ELEVATION U
ORDER #:
203804, 203826
11
2/6 SALESFORCE #:
13 482328
42" 61.75" 61.75" 37" 37" 37" 37" 37" 46.38" 46.38" 46.38" 46.38"
2/6
DATE:
41" 41" 41" 08/06/2020

REVISIONS:
N0. DATE BY DESCRIPTION

1 08/19/2020 MJS APPLY VFD'S/ INSTALL

2 08/28/2020 MJS ELEVATION CHANGES

3 09/04/2020 MJS ELEC/ LOADBARS

4 09/10/2020 MJS REVISE SPECIALS

D3 BG3 BG3 S16 S17 S28 S19 S18 S1 S1 S1 S25 S22 S16 S16
12
2/6
DRAWN BY: SCALE:
ELEVATION V ELEVATION W ELEVATION X ELEVATION Y MJS AS NOTED

DRAWING #:
D227361_NJ_06_L01_W_04.cmdrw
ELEVATIONS Scale1/4" = 1' 9/10/2020 8:15:33 AM

SHEET: ELEVATIONS
3/6

V20.0

FIELD VERIFIED DIMENSIONS


DRAWING REVIEW
THESE PLANS ARE INTENDED TO COMPLY WITH THE
CONTRACT. AS SUCH, THESE PLANS MUST BE
REVIEWED BY THE
OWNER/ARCHITECT/CONTRACTOR, OR OTHER
APPROPRIATE REPRESENTATIVE. IF KI IS TO
PROCEED WITH PRODUCT INSTALLATION IN
ACCORDANCE WITH THESE PLANS, MARK THE
"APPROVED AS NOTED" BOX BELOW, EXECUTE AND
COMPLETE THE INFORMATION AT THE BOTTOM OF
THIS PAGE, AND RETURN THIS DOCUMENT TO KI. IF
THESE PLANS ARE TO BE CORRECTED, MARK THE
"REVISE AND RESUBMIT" BOX BELOW, EXECUTE
AND COMPLETE THE INFORMATION AT THE BOTTOM
OF THIS PAGE, AND RETURN THIS DOCUMENT TO KI.
AUTHORIZED SIGNATURE INDICATED REVIEW OF
THESE PLANS. BELOW SIGNATURE, PRINT NAME,
TITLE, COMPANY OR AFFILIATION, AND DATE.
MANUFACTURE OF PRODUCT SHOWN IS NOT
SCHEDULED UNTIL DRAWING REVIEW IS COMPLETE
AND AUTHORIZED SIGNATURE IS RECEIVED.
IT IS THE OWNER/ARCHITECT/CONTRACTOR'S
RESPONSIBILITY TO NOTIFY KI IF SITE CONDITIONS
HAVE CHANGED OR ARE NOT DEPICTED ON OUR
DRAWING THAT WOULD IMPACT OUR FURNITURE
LAYOUT AFTER COMPLETED FIELD VERIFIED
DIMENSIONS HAVE BEEN OBTAINED.

APPROVED AS NOTED

REVISE AND RESUBMIT

SIGNATURE:

PRINT:

KI REP INITIALS:

DATE:

APPROVAL STAMP

7'-0" CORNICE HEIGHT 8'-6" CEILING HEIGHT 8'-6" CEILING HEIGHT

MDF1/D1
2.28WP2C2C2
D
1

37S18
1

37S19
2

CONF.
D
CONF.
OFFICE OFFICE W
ROOM

15' -9-1/2"
ROOM CONF. ROOM

37S28
PT-1

084 TV-1 3/6 OFFICE


086
036 039 040
037
OFFICE

37S17
1 038 8'-0" CEILING HEIGHT

37S16
UCON
058 059
OFFICE 055 057 A-NL A-NL 063
M

A-NL A-NL A-NL


D

2.19WP2A1A1
F1

38 42D2LHR 42D2RHR 2.31WP2A1A1


/D

.1 2.27WP2A1A1 2.37WP2A1A1 2.25WP2A1A1


42D3LHR 42D3LHR 42D2RHR
1

3
SC
O
N 1
S1
1 083 63.25BG3 UCON 101BG3 101BG3 UCON
71.75BG2 71.75BG2 FM2FHA1A1 65.75BG2 65.75BG2
40.25T2
OFFICE

SCON
UCON
15' -9-7/16" 14' -9-9/16"
38 7' -1" 064
30' -7" 041
12

.1 9' -0" 20' -6-7/8" A-NL


3S

51.5T1
'-

42
8'-0" CEILING HEIGHT
9-

U
15

D
9

3R
/1

O
Q
6"

H
R
2
D 1
38
.1 7' -10-1/2"
J
M LEGAL OPEN P 3/6
3/6
3S
LEASING/ 3/6

8'
6 3/6 WORKSPACE

-6
"C
8'-6" CEILING HEIGHT
42D1RHR

9'
FINANCE OPEN

EI
7'-0" CORNICE HEIGHT

-
38
OFFICE

11
M

054 11' -0-3/8"

74
LI

2.
.1
D

-1

25
OFFICE 3S A-NL
F1 8S1

.5
035

/4
N

B
SCON

W
"
1
/D
35

G
G

P2
1

3
.8

WORKSPACE K FMC4A1

A1
SC 88.13BG1

H
042

A1
O

EI
SC

1 N
082
O

G
3/6 42D1LHR
N

SCON

H
065

T
35

38.81S1
090 027 A-NL
.8

12

42
8S

A-NL
'-

U
2/6

D
2"
1

3R
5

O
N

H
2

R
1 26' -11-7/8"

6' -9-1/8"
D
UCON
35
.8

38.91D5R 48.88T3 48.88T3 48.88T3 48.88T3 48.88T3 37.88T3


8S
6

38.81S1

FM24C2C2
2.21WP2A1A1
FMC4A1

10
018
35

BMEC2
053

BMEC2

'-
40.5S1 40.5S1 40.5S5 40.5S7 C
OFFICE
.8

OFFICE

77
1-
A-NL

2.
8

13' -6-1/4"
OFFICE

7/

.3
S1

35
8"

8B

W
SC

G
T
2 D 1 SCON

P2
42D1LHR

3
O

A1
N

T
A1 1
034

A1
081 /
42

53.81T1 SCON
35
043
.1

38.81S2
/1
9S

1 90
3

3/ 80.25BG1
066
FM 8' -1-13/16" A-NL

42
1

D
1

6' -9-1/8"

3R
G

O
3B

H
42

.1

R
81
.1

R
5'

H
10' -5-3/4"
9S
- 8-

4
1/

38.81S1
"
2"

3/6
10

2 3/6
10

OFFICE
1/
'-

D 052
7-

OFFICE
7-

'-
7/

A-NL
10

R
8"

42

H
1R D 1

10
.1

BMEA1 FMC4A1 SCON


M

9S

'-
088 INVESTMENTS
D

42

4-
F1

79
BMEA1
1

2.
1/
044

.5
35

/D

12
8"
FMC4A1
42D1LHR

43.38S9 43.38S12 43.38S9

B
1

81BG1
. 94

W
3

P2
017
S1

OFFICE
T

A1
SC

OPEN

A1
1

1 A-NL
T

34 42D1LHR FMC4A1
EXECUTIVE
O

A1
N

FM N
"
16

O
20' -11-1/2"

049
35

1
3/

I
41S1

41S1

40.5S1 40.5S5 40.5S7


.9

2-

A-NL 067
080 CONF. ROOM 3/6 WORKSPACE
4S

'-

3/6 A-NL
21

G
15

42
1
3/6

U
BG 40.5S7

D
FM34A1 2 D 1

C
2 SCON

3R
13

O
1
1.

N
3/6

H
D
027

R
8 22' -3-1/4" 41' -11-5/8"
35

045
.9

11' -1-5/8" 11' -1-5/8"


4S

"

11' -1-1/8" 11' -1-1/8" 11' -1-1/8" 8' -8-1/4"


10
6

1/

051 FMC4A1
80.25BG1

88.13BG1 88.13BG1 FMC4A1


7-

41S1

41S1

87.63BG1 87.63BG1 87.63BG1 60T1


'-

A-NL R
10

H
35

1R 42D1LHR 42D1LHR FMC4A1 42D1LHR FM34A1 42D1LHR 42D1LHR 42D1LHR SCON


M

FM34A1 FM34A1

10
OFFICE
FM

FM34A1
.9

2D
D

13' -11-1/2"
4S

'-
4
F1

3/

75
0-
40.25S1

40.25S1

40.25S1
10' -5-3/4"

2.
1

OFFICE
90

40.25S1

40.25S1

40.25S1

40.25S1
021 022
/D

023 024 025 026

1/

.7
37

25
/1
1

2"

5B
A-NL A-NL
.8

W
A-NL A-NL A-NL A-NL
35
1S

P2
/A

1 2

3
SC

087
11

A
1

1A
O

D
N

1
079
41S2

41S5

OFFICE
37

52.5T1
.8

1 1 1 1
1S

40.25S2
14

40.25S1

40.25S1
40.25S2
42D1LHR

40.25S1

40.25S2

40.25S2
2
D 1
016 089 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
8' -0-3/16"

A-NL
019 020
37

13' -7-1/4"

13' -7-1/4"
C C
12

.8

029 031 032 033 OFFICE


41S1

41S2

028
'-

1S

FMC4A1 1 SCON
8-

030
10

BMEC2
7/
16

BMEC2 1 2 2 1 2 2 2
"

42D1RHR

40.5S1 40.5S1 40.5S7 40.5S1 38.91D5L 48.88T3 48.88T3 48.88T3 48.88T3 48.88T3 38.91D5R
D D

40.25S2

40.25S5

40.25S5
FMC4C2 1 D D D

40.25S2

40.25S5

40.25S5

40.25S5
050 FMC4A1
M

UCON UCON
37

046
D

A-NL
T
.8
F1

26' -11-3/8"
T

6 13' -8-1/4"
1S
/D

8'-6" CEILING HEIGHT


SCON
35

41S9 41S9 41S9


1

D
S2

2/6
2
SC
4

L
2.

10' -6-1/2"
1W

1
OFFICE
P2

3/6 8'-6" CEILING HEIGHT


C2

35
C2

40.25S1

40.25S8

40.25S8

40.25S1

40.25S8

40.25S8

40.25S8
S2

8
0

2 078 2/6

SCON
SCON

SCON

SCON
SCON
1 1

SCON
SCON
D 1 1 1
D D D D D
35
S2
12

1
'-
1-

068
7/
16

096 A-NL
35
"

S1

A-NL
FM 35W

2.21WP2A1A1
6

42D3RHR
3.

3/ P4

LEGAL PRINT
90

42D2RHR 2.39WP2A1A1
/1 2C
35

62.13BG3 62.13BG3

UCON
CONSTR.
/A
C

IDF ROOM
1

51.25T2
ROOM UCON
UP

42D3RHR
2

UP
8' -1-7/8" 069
STOR. 091
14' -0-15/16"
A-NL

F 004 S
72.5BG2

3/6 025
3/6
CONF. ROOM

10' -3-1/8"
9' -10-1/2"

OFFICE LEGAL FILE 047

78.5BG3
LEGAL FILE ROOM TAX PRINT

2.13WP2A1A1
077 ROOM
42D2RHR

095
A-NL LEASING/ ROOM
MDF1/D1
46.38S26
006 T
46.38S17 1 PT TV 46.38S27 1 46.38S16 FINANCE 003 3/6
007
RAMP UP

2.25WP2C2C2 UCON
SITE RECEPTION STORAGE IT STORAGE

RAMP UP

RAMP UP
1
PANTRY
FM2FHA1A1
42D2LHR

UCON
5

42D3RHR
094
A-NL DEV. 002
ROOM 070

026 001 A-NL

FILES 005

8' -4-5/8"
OFFICE
29' -8-5/8"
9' -11-5/8"

E
024
3/6
CONSTRUCTION OPEN

55.75T3
076

2.37WP2A1A1
74.13BG2

MDF1/D1
15' -8-1/4" WORKSPACE
46.38S25
UCON OFFICE
D 1 2 D 46.38S16 46.38S16 074 LEGAL LIBRARY
1 46.38S22 048
HALLWAY
FM24A1A1
42D2LHR

2.25WP2C2C2
093
A-NL
Y ENG. 008
3/6 FILES 7'-0" CORNICE HEIGHT
9' -10-9/16"

OFFICE
023
72.5BG2

075 OFFICE
2.31WP2A1A1

4 JAN. 049
2/6

B01 STAIR #2

7'-0" CORNICE HEIGHT UP UP


8'-0" CEILING HEIGHT D
3/6
MECH. TAX FILE
16' -6-1/2" ROOM
10' -0-1/4" 6' -6-1/4" SHAFT B02
T
74.76BG1
T
T
74.76BG1
009 STOR.
T

42D1LHR FM24A1A1 FMC4A1


FMC4A1 BMEA1
091 BMEA1 050
41S1

41S1

BMEA1 A-NL
BMEA1

1 OFFICE STAIR #3 MEN


X
10' -6-1/2"

B05
41S1
41S2

073 3/6

42D3RHR
UCON
073
PRINT A-NL

CONF. ROOM BMEC2


AREA
41S1

41S1

BMEC2
BMEC2
FMC4C2
BMEC2
FMC4A1 FM24C2C2 D 2 1
022 ELEV. ELEV. OFFICE
T

T T

61.75BG3
T

072 47.88S1 47.88S1 47.88S13 47.88S11

STAIR #1 051

14' -0-3/8"
8' -3-1/4" 8' -3-1/4" MECH. V
16' -6-1/2"
3/6 CONF.
B04
ROOM
DINING AREA 052

61.75BG3

2.37WP2A1A1
012

ELEC.
ELEC. B03
UP UP
B08
WOMEN 075
A-NL

B06 WELLNESS 42D2RHR 2.4WP2A1A1

ROOM CONSTR. STORAGE UCON


11' -5-3/8"
92.5BG2

011 010 U
ARCH.
8'-0" CEILING HEIGHT
3/6 OFFICE
SAMPLE
AREA 053

021

OFFICE
ARCH.
054
RAMP UP

RAMP UP
FILES
RAMP UP

020 MECH. ACCT.


PRINT ROOM MAIL ROOM I.T.
B07 AUDITOR'S
ACCOUNTING COMMAND COMPUTER
FILE ROOM ROOM
CENTER ROOM
018 016 015
017 014 013
TAX OPEN OFFICE
HYDRATION WORKSPACE
055
INSTALLATION PLAN
STATION MARY S.
8'-0" CEILING HEIGHT 056
019
UCON

45.5T2

7' -4-1/2"

C
CONF.
3/6
ROOM
42D2RHR

088
A-NL
UCON

069
U
C
O
N

ARCH.
42
D
2L
H

089
B
R

A-NL

3/6
OPEN
47
.3

WORKSPACE
1T

15
2

'-
6-
3/
16
"

070
47
.3
1T
2

PROJECT TITLE:
47
.3

OFFICE HARTZ MOUNTAIN INDUSTRIES


1T
3.

2
5B
M
E4

INC
A1

071
T

N
O
H

C
U

6
G

S1

500 PLAZA DRIVE


EI

.5
37
H
G
IN

SECAUCUS
1
L

S2
EI

.5
48

"
8'-0" CEILING HEIGHT NJ 07094
"C

4
1 1/
D 7-
'-
-6

2
P2 1
2C

11 A
5W 1/D
C
8'

FLOOR/AREA:
F
D

I.T. OPEN
3
M

3/6
S2
2.

.5
48

26' -0-1/16"
WORKSPACE 6TH FLOOR
67.13BG4 67.13BG4 38.91D6L 67.13BG4 67.13BG4

2.35WP2A1A1 2.3WP2A1A1 057 REPRESENTATIVE:


084
D
GIGSTEAD, CHRISTINA
ACCOUNTING/ OFFICE SERVICES ORDER #:
OPEN WORKSPACE 203804, 203826
063
SALESFORCE #:
PAYROLL/ HR 482328
064 DATE:
PROP. MANAGEMENT
OPEN WORKSPACE 08/06/2020
068 REVISIONS:
N0. DATE BY DESCRIPTION

1 08/19/2020 MJS APPLY VFD'S/ INSTALL

2 08/28/2020 MJS ELEVATION CHANGES


CONF. ROOM 3 09/04/2020 MJS ELEC/ LOADBARS
OFFICE 4 09/10/2020 MJS REVISE SPECIALS
CONF CONF. ROOM
OFFICE OFFICE 062 061
ROOM OFFICE OFFICE
067 066 065 060 059 058

DRAWN BY: SCALE:


MJS AS NOTED

DRAWING #:
FLOOR PLAN Scale1/8" = 1' D227361_NJ_06_L01_W_04.cmdrw
9/10/2020 8:15:34 AM

SHEET: FLOOR PLAN


4/6

V20.0

FIELD VERIFIED DIMENSIONS


DRAWING REVIEW
THESE PLANS ARE INTENDED TO COMPLY WITH THE
CONTRACT. AS SUCH, THESE PLANS MUST BE
REVIEWED BY THE
GENIUS ELECTRICAL LEGEND OWNER/ARCHITECT/CONTRACTOR, OR OTHER
APPROPRIATE REPRESENTATIVE. IF KI IS TO
CONVENTIONAL ELECTRICAL LISTED TOP TO BOTTOM IS LEFT TO RIGHT IN PANEL PROCEED WITH PRODUCT INSTALLATION IN
ACCORDANCE WITH THESE PLANS, MARK THE
SYMBOL QTY LOCATION BOX SIZE FEED PREWIRED GANG CIRCUIT# DEVICE COLOR FACEPLATE COLOR TYPE CONDUIT LENGTH CONDUIT "APPROVED AS NOTED" BOX BELOW, EXECUTE AND
BOTTOM NO N/A BY OTHERS ELECTRICAL 3/4" FLEX COMPLETE THE INFORMATION AT THE BOTTOM OF
18 SHELL 4X4 DOUBLE 2 BY OTHERS INCLUDED THIS PAGE, AND RETURN THIS DOCUMENT TO KI. IF
2 BOTTOM NO N/A BY OTHERS ELECTRICAL 3/4" FLEX
THESE PLANS ARE TO BE CORRECTED, MARK THE
"REVISE AND RESUBMIT" BOX BELOW, EXECUTE
BOTTOM NO N/A BY OTHERS ELECTRICAL 3/4" FLEX AND COMPLETE THE INFORMATION AT THE BOTTOM
1 SHELL 4X4 DOUBLE BOTTOM NO 2 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX OF THIS PAGE, AND RETURN THIS DOCUMENT TO KI.
PT-1
AUTHORIZED SIGNATURE INDICATED REVIEW OF
THESE PLANS. BELOW SIGNATURE, PRINT NAME,
TITLE, COMPANY OR AFFILIATION, AND DATE.
42 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX
1 MANUFACTURE OF PRODUCT SHOWN IS NOT
SCHEDULED UNTIL DRAWING REVIEW IS COMPLETE
AND AUTHORIZED SIGNATURE IS RECEIVED.
27 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS DATA INCLUDED 1" FLEX IT IS THE OWNER/ARCHITECT/CONTRACTOR'S
D RESPONSIBILITY TO NOTIFY KI IF SITE CONDITIONS
HAVE CHANGED OR ARE NOT DEPICTED ON OUR
DRAWING THAT WOULD IMPACT OUR FURNITURE
1 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 3/4" FLEX LAYOUT AFTER COMPLETED FIELD VERIFIED
PT
DIMENSIONS HAVE BEEN OBTAINED.

APPROVED AS NOTED
1 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS DATA INCLUDED 1" FLEX
TV-1
REVISE AND RESUBMIT

SIGNATURE:
1 SHELL 4X4 SINGLE VERT BOTTOM NO 1 N/A BY OTHERS BY OTHERS ELECTRICAL INCLUDED 1" FLEX
TV
PRINT:
FLEXIBLE CONDUIT TO EXTEND 2' OUT OF THE BOTTOM FRAMEWORK OF THE PANEL
EMT CONDUIT TO EXTEND 1" OUT OF THE BOTTOM FRAMEWORK OF THE PANEL KI REP INITIALS:
ALL ADDITIONAL ELECTRICAL COMPONENTS TO BE SUPPLIED BY OTHERS
2 PIECES OF CONDUIT MAXIMUM CAN BE ROUTED THROUGH THE BASE AND UP THROUGH A POST AND CEILING RAIL DATE:
POSTS AT FLOOR MAY NEED TO BE CUT FOR CONDUIT ACCESS
APPROVAL STAMP

7'-0" CORNICE HEIGHT 8'-6" CEILING HEIGHT 8'-6" CEILING HEIGHT

D
1

CONF.
D
CONF.
OFFICE OFFICE
ROOM PT-1 CONF. ROOM ROOM
084 TV-1 OFFICE
086
036 039 040
037
OFFICE
1 038 8'-0" CEILING HEIGHT

OFFICE

1
083 OFFICE
041
2
D 1
LEGAL OPEN
LEASING/ WORKSPACE
8'-6" CEILING HEIGHT
FINANCE OPEN 7'-0" CORNICE HEIGHT OFFICE
OFFICE 035
1 WORKSPACE 042
082
090
2
D 1

OFFICE OFFICE OFFICE

T
2 D 1

T
081
1
034
1
043
1

2
D OFFICE OFFICE
D 1
088 INVESTMENTS 044
OFFICE
T

1
OPEN
T

EXECUTIVE
1

2
080
2 D 1
CONF. ROOM WORKSPACE
D 1
027
045

OFFICE
OFFICE
1 2
1 087 D
079 OFFICE
1 1 1 1
2
D 1 089 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE
1 028 029 031 032 033 OFFICE
1 2 2 1
030 2 2 2
1 D D D D D
046
T

8'-6" CEILING HEIGHT D


2

1
OFFICE 8'-6" CEILING HEIGHT
2
D
078 1 1 1 1 1
D D D D D

LEGAL PRINT
CONSTR. IDF ROOM ROOM
UP

UP
STOR. 091 004
025
CONF. ROOM
OFFICE LEGAL FILE 047
077 ROOM LEGAL FILE ROOM TAX PRINT
LEASING/ ROOM
003 006
1 PT TV 1 FINANCE
007
RAMP UP

SITE RECEPTION STORAGE IT STORAGE

RAMP UP

RAMP UP
1
PANTRY
DEV. 002
ROOM
026 001
FILES 005
OFFICE
024
076 CONSTRUCTION OPEN
WORKSPACE
OFFICE
D 1 2 D
074 LEGAL LIBRARY
1 048
HALLWAY
ENG. 008
FILES 7'-0" CORNICE HEIGHT
OFFICE
023
075 OFFICE
JAN. 049
B01 STAIR #2

7'-0" CORNICE HEIGHT UP UP


8'-0" CEILING HEIGHT
MECH. TAX FILE
ROOM
SHAFT B02
T
T
T
009 STOR.
T

050

1 OFFICE STAIR #3 MEN


073 B05

PRINT
CONF. ROOM AREA
D 2 1
022 ELEV. ELEV. OFFICE
T

T T
T

072
MECH. STAIR #1 051
CONF.
B04
ROOM
DINING AREA 052
012

ELEC.
ELEC. B03
UP UP
B08
WOMEN
B06 WELLNESS
ROOM CONSTR. STORAGE
011 010
ARCH.
8'-0" CEILING HEIGHT OFFICE
SAMPLE
AREA 053

021

OFFICE
ARCH.
054
RAMP UP

RAMP UP
FILES
RAMP UP

020 MECH. ACCT.


PRINT ROOM MAIL ROOM I.T.
B07 AUDITOR'S
ACCOUNTING COMMAND COMPUTER
FILE ROOM ROOM
CENTER ROOM
018 016 015
017 014 013
TAX OPEN OFFICE
HYDRATION WORKSPACE
055
INSTALLATION PLAN
STATION MARY S. 056
019

CONF.
ROOM
069

ARCH.
OPEN
WORKSPACE
070
PROJECT TITLE:
OFFICE HARTZ MOUNTAIN INDUSTRIES
071 INC
500 PLAZA DRIVE

SECAUCUS
1 8'-0" CEILING HEIGHT NJ 07094
D

I.T. OPEN FLOOR/AREA:


WORKSPACE 6TH FLOOR

057 REPRESENTATIVE:
GIGSTEAD, CHRISTINA
ACCOUNTING/ OFFICE SERVICES ORDER #:
OPEN WORKSPACE 203804, 203826
063
SALESFORCE #:
PAYROLL/ HR 482328
064 DATE:
PROP. MANAGEMENT
OPEN WORKSPACE 08/06/2020
068 REVISIONS:
N0. DATE BY DESCRIPTION

1 08/19/2020 MJS APPLY VFD'S/ INSTALL

2 08/28/2020 MJS ELEVATION CHANGES


CONF. ROOM 3 09/04/2020 MJS ELEC/ LOADBARS
OFFICE 4 09/10/2020 MJS REVISE SPECIALS
CONF CONF. ROOM
OFFICE OFFICE 062 061
ROOM OFFICE OFFICE
067 066 065 060 059 058

DRAWN BY: SCALE:


MJS AS NOTED

DRAWING #:
ELECTRICAL PLAN Scale1/8" = 1' D227361_NJ_06_L01_W_04.cmdrw
9/10/2020 8:15:38 AM

SHEET: ELECTRICAL PLAN


5/6

V20.0

FIELD VERIFIED DIMENSIONS


CONNECTOR TYPES

CONNECTOR LEGEND
TAG PART NUMBER DESCRIPTION FINISH
A FHF/079.900/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
B FHF/079.900/C2 FULL LENGTH FLUSH CONNECTOR SATIN SHEET TEXTURED
C FHF/084.000/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
D FHF/084.000/C2 FULL LENGTH FLUSH CONNECTOR SATIN SHEET TEXTURED
E FHF/092.250/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
F FHF/096.000/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
G FHF/098.250/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
H FHF/098.250/C2 FULL LENGTH FLUSH CONNECTOR SATIN SHEET TEXTURED
J FHF/102.000/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
K FHF/102.000/C2 FULL LENGTH FLUSH CONNECTOR SATIN SHEET TEXTURED
L FHF/115.900/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
M FHF/115.900/C2 FULL LENGTH FLUSH CONNECTOR SATIN SHEET TEXTURED
N FHF/118.650/A1 FULL LENGTH FLUSH CONNECTOR CLEAR ANODIZED ALUMINUM 8-MINUTE ETCH
O FHR/079.900/RAO FULL LENGTH RECESSED CONNECTOR ANODIZED GRAY
P FHR/084.000/RAO FULL LENGTH RECESSED CONNECTOR ANODIZED GRAY
Q FHR/092.250/RAO FULL LENGTH RECESSED CONNECTOR ANODIZED GRAY
R FHR/096.000/RAO FULL LENGTH RECESSED CONNECTOR ANODIZED GRAY
S FHR/111.800/RAO FULL LENGTH RECESSED CONNECTOR ANODIZED GRAY
T FHR/118.650/RAO FULL LENGTH RECESSED CONNECTOR ANODIZED GRAY

7'-0" CORNICE HEIGHT 8'-6" CEILING HEIGHT 8'-6" CEILING HEIGHT

K
H

H
CONF. CONF.
OFFICE

H
OFFICE ROOM
ROOM OFFICE CONF. ROOM
084 086
036 039 040
037

H
OFFICE
038 8'-0" CEILING HEIGHT

H
D OFFICE
D F E F FF F E F

K
J J J J G J J F F F
083 F E F FF F E F OFFICE

C
J J J J G J J F F F
B

J
B
041

J
B
B LEGAL OPEN

J
LEASING/

J
C

C
B
8'-6" CEILING HEIGHT
WORKSPACE
B
FINANCE OPEN 7'-0" CORNICE HEIGHT OFFICE
D

OFFICE 035
D

D
WORKSPACE C C C
042

O
A
C

C
082 D

J
P C C
B

J
J
B

090

J
B
B

J
B

B
J J G G G G G J

J
B

J J G G G G G J
B

A B B B D
OFFICE OFFICE OFFICE

O
A

MM

MM
O B B B D

T
C C C
D

T
034
D

081
C

CC C C
043

J
J
J
J
B
B

J
J
C
OFFICE
B

C OFFICE
B

C
O B B D
D

088 INVESTMENTS

O
A
044
D

N C A A B B D
P
O

O
OFFICE
T

O
S

A
L

C
OPEN
T
O

A T C O
EXECUTIVE
B

J
B

J
O B B B D
CONF. ROOM WORKSPACE

J
080

AC

OP

J
O B B B D
B

027
B

045

J
C

J
C C AC C A C C AC C AC C AC C C
B

O
A

O
A
B

P C OP C O P C OP C OP C OP C C
OFFICE
D

OFFICE
D

C
C
C

C 087
C

079
B

OFFICE

J
B

B
C

B
B

J
089 OFFICE OFFICE OFFICE OFFICE OFFICE
B

OFFICE
B
B

028 029 031 032 033 OFFICE


C

O B B B D J J G G G G J J
030

B
C

P
B

A B B B D J J G G G G J J
B

O B B S
046
K

M
O
A

S
T

8'-6" CEILING HEIGHT


K

A B B M
D

B
OFFICE
H

8'-6" CEILING HEIGHT


H

078
H
H

D
H
H

J J G J
LEGAL PRINT
K

F F F

J
J J G J
CONSTR.
Q
K
E

R F F
IDF ROOM ROOM

UP

UP
STOR. 091 004
025

J
CONF. ROOM
OFFICE LEGAL FILE 047
F

077 ROOM LEGAL FILE ROOM TAX PRINT


LEASING/ ROOM
003 006
K H H H K FINANCE

J
FF

FF

007
RAMP UP

K H H H K
RECEPTION STORAGE IT STORAGE

J
SITE

RAMP UP

RAMP UP
PANTRY
DEV. 002
ROOM
026 001
FILES 005
F

J
OFFICE
024
076 CONSTRUCTION OPEN
WORKSPACE
OFFICE

J
K H H H K 074 LEGAL LIBRARY
FF

FF

K H H H K 048
HALLWAY
ENG. 008
FILES 7'-0" CORNICE HEIGHT
F

OFFICE
023
075 OFFICE
JAN. 049
B01 STAIR #2
F

7'-0" CORNICE HEIGHT UP UP


8'-0" CEILING HEIGHT
MECH. TAX FILE
ROOM
SHAFT B02
N
T
C LL
T
T
A
009 STOR.
O
S

A
L
T

T C LL O

050

OFFICE STAIR #3 MEN


B

073 B05

J
B

PRINT
CONF. ROOM AREA

J
O B MM B S
022 ELEV. ELEV. OFFICE
M
O
A

S
T

T T
T

072 A B MM B M

MECH. STAIR #1 051


CONF.
B04
ROOM

G
DINING AREA 052
012

ELEC.

J
ELEC. B03
UP UP
B08
WOMEN
B06 WELLNESS F F F

ROOM CONSTR. STORAGE F F F

011 010
ARCH.
8'-0" CEILING HEIGHT OFFICE
SAMPLE
AREA 053

021

OFFICE
ARCH.
054
RAMP UP

RAMP UP
FILES
RAMP UP

020 MECH. ACCT.


PRINT ROOM MAIL ROOM I.T.
B07 AUDITOR'S
ACCOUNTING COMMAND COMPUTER
FILE ROOM ROOM
CENTER ROOM
018 016 015
017 014 013
TAX OPEN OFFICE
HYDRATION WORKSPACE
055
STATION MARY S. 056
019
F

CONF.
INSTALLATION PLAN
F

ROOM
069
F

F
F
F

ARCH.
OPEN
F
F

WORKSPACE
E
E

070
E
E

OFFICE
F
K

071
F

K
H
H

PROJECT TITLE:
8'-0" CEILING HEIGHT
H

HARTZ MOUNTAIN INDUSTRIES


H

I.T. OPEN INC


K

WORKSPACE
K

500 PLAZA DRIVE


F E F F E F

F E F F E F 057 SECAUCUS
NJ 07094

ACCOUNTING/ OFFICE SERVICES FLOOR/AREA:


OPEN WORKSPACE 6TH FLOOR
063
REPRESENTATIVE:
PAYROLL/ HR GIGSTEAD, CHRISTINA
064 ORDER #:
PROP. MANAGEMENT
OPEN WORKSPACE 203804, 203826
068 SALESFORCE #:
482328
DATE:
08/06/2020
CONF. ROOM
OFFICE REVISIONS:
CONF CONF. ROOM
OFFICE OFFICE 062 061 N0. DATE BY DESCRIPTION
ROOM OFFICE OFFICE
066 1 08/19/2020 MJS APPLY VFD'S/ INSTALL
067 065 060 059 058
2 08/28/2020 MJS ELEVATION CHANGES

3 09/04/2020 MJS ELEC/ LOADBARS

4 09/10/2020 MJS REVISE SPECIALS

DRAWN BY: SCALE:


MJS AS NOTED

DRAWING #:
D227361_NJ_06_L01_W_04.cmdrw
CONNECTOR PLAN Scale1/8" = 1' 9/10/2020 8:15:40 AM

SHEET: CONNECTOR PLAN


6/6

V20.0

You might also like