You are on page 1of 1

1.

ALL TAGS MUST BE ACCORDING TO PDVSA STANDARD


2. ALL RELIEF VALVES MUST GO TO A FLARE HEADER
3. FOR THE REST OF THE 60 PSIG TRAINS, REPLACE THE FIRST FOUR DIGITS AS SHOW:
TRAIN No. TRAIN No. TRAIN No.
2 3 4
6302 6303 6304
1902 1903 1904
1402 1403 1404

Electric Heater EH-2113101/201/301/401


Code of Construction ASME section VIII Div. I - 2004 Edition
Description 165 kW Circulation Heater
480 V, 3 Phase - 50 Hz
Design Pressure 550 PSIG
Design Temperature +20 F / 300 F
Operating Flow Rate 4 mmscfd
Corrosion Allowance 0.0625"
Materials of Construction Carbon Steel
Size 10" NPS X 94" OAL

Heat Exchanger E-2113101/201/301/401


Code of Construction ASME section VIII Div. I and TEMA -C
Description Shell and Tube - 08-060 Type E
Design Pressure Shell 550 PSIG / Tube 655 PSIG
Design Temperature Shell / Tube +20 F / 300 F
Operating Flow Rate 4 mmscfd
Corrosion Allowance 0.0625"
Materials of Construction Carbon Steel
Size 8" NPS X 60" OAL

Coalescer - FL-2113101/FL-2113102
Code of Construction ASME section VIII Div. I - 2004 Edition 2006 Addenda
Description Coalescing
Design Pressure 550 PSIG
Design Temperature 300 F
Operating Flow Rates 4 mmscfd @ 325 PSIG & 146 Deg. F
Corrosion Allowance 0.0625"
Materials of Construction Carbon Steel
Size 12" NPS x 82 Seam to Seam
Filters 2710E2 (qty 1)
Removal Efficiency 100% Solids & Liquids - 5 micron or Greater

Document Tag
Customer: Jantesa Corporation
Project Name: Gas Anaco Project - Santa Rosa Venezuela
P.O. No.: 7662-03-M-995-PO-800-E
Service: Fuel Gas Conditioning System
Tag no.: X-2113153/253/353/453

NOTES
1 Electrical Area Classification NEC class I Divisiom II - Group D
2 Structural Design and Fabrication IAW AWS D.1.1
3 Piping Design and Fabrication IAQ ASME B31.3
4 Reference Document # S0127-21235-DMD7302 Rev.B
No insulation is Considered for the system other than the Insultation Supplied
5
with the Electric Heater

You might also like