FTeX advanced wireline formation

pressure testing service


Acquire pressure data accurately
and efficiently with automation
and real-time control
Applications
• Openhole logging
• Slimhole logging
• High-pressure environments
The FTeX™ advanced wireline effort to run a test. By adapting the
formation pressure testing service formation response from the first • All formation types
from Baker Hughes delivers reliable and drawdown and defining a behavior for
accurate pressure data by combining subsequent drawdowns in real time, the Benefits
downhole automation with real-time service determines optimal pressure • Automates pressure
control. It provides critical formation measurements, leading to increased measurements and analysis and
data—from pressure profiles to fluid data accuracy and time utilization. calculates mobility data
contact and mobility information—as
Combinable with other wireline • Reduces risk of human error by
early as the first logging run to help
formation evaluation and petrophysical enabling downhole automation
reduce time in the well. This offers
services, the FTeX service decreases time and real-time control
reservoir engineers and petrophysicists
dedicated to evaluation, saving valuable
the opportunity to make earlier decisions • Saves rig time by providing
rig time and cost. Additionally, the
about how to best proceed with their pressure profiles as early as the
intelligent platform’s electrical features
formation evaluation objectives. first logging run
minimize risk of system failure, and its
With conventional pressure testing precise pressure gauge acquires some • Enhances efficiency by reducing
services, inaccurate data is possible of the most accurate measurements in number of runs
due to inconsistent test outcomes the industry. • Ensures accurate measurements
derived from manual measurements.
For more information on how the
Using its intelligent platform, the FTeX
FTeX service can help you obtain
service reduces the possibility of
accurate pressure data more reliably
human error and minimizes test time by
and efficiently, contact your Baker
optimizing the operation sequence. Test
Hughes representative today or visit
parameters and controls for drawdowns
bakerhughes.com.
are set automatically, requiring minimal

Specifications
Temperature 350°F (177°C)

Pressure rating 30,000 psi (207 MPa)

Minimum borehole size 4.75 in.

Maximum borehole size 16 in.

Tool OD 3.88 in. (98.55 mm)

Copyright 2019 Baker Hughes Company. All rights reserved. 80600 bakerhughes.com