CAT MARINE ENGINES
AUXILIARY RATINGS
Engine
Model bkW/bhp
3616 DITA 4600-5420/6169-7268
3612 DITA 3460-4060/4640-5444
3608 DITA 2300-2710/3084-3634
3606 DITA 1730-2030/2320-2722
50 Hz 50 Hz 60 Hz 60 Hz
Engine
1500 rpm 1000 rpm 1800 rpm 1200 rpm
Model
bkW/bhp bkW/bhp bkW/bhp bkW/bhp
3516B DITA 1566-1717/ 1287/1726 1901/2549 1383/1855
2100-2303
3512B DITA /1020-1257/ 933/1251 1125-1424/ 1102/1478
/1368-1686 1509-1910
3508B DITA 673-856/ 649/870 760-968/ 682/915
903-1148 1019-1298
3516 DITA 1355/1817 1100/1475 1511/2026 1230/1650
3512 DITA 1020/1368 860/1153 1125/1509 955/1281
3508 DITA 673/903 446/598 760/1019 599/804
3412C DITA /431-534/ — /450-620/ —
/578-716 /603-831
3408C DITA 340/456 — 410/550 —
3406C DITA /229-260/ — /277-345/ —
/307-349 /371-462
**Approval not required under 130 bkW (174 bhp).
**Non IMO compliant.
See us at
www.Cat-engines.com
CAT GENERATOR SETS
DIESEL AND POWER MODULE RATINGS NATURAL GAS RATINGS
60 Hz 50 Hz 60 Hz 50 Hz
1800 rpm 1500 rpm 1800 rpm 1500 rpm
Standby eKW Prime eKW Cont. eKW Standby kVA Prime kVA Cont. kVA Standby eKW Continuous eKW Standby kVA Continuous kVA
230 - 2250 210 - 1825 660 - 1640 275 - 2500 250 - 2275 812 - 2000 150-1040 100-2055 - 106-2500
1200 rpm 1000 rpm
1200 rpm 1000 rpm
Standby eKW Prime eKW Cont. eKW Standby kVA Prime kVA Cont. kVA
Standby eKW Continuous eKW Standby kVA Continuous kVA
- 425 - 1450 400 - 1325 2688 - 7150 500 - 6500 488 - 5875
- 365-1600 - 1588-4825
900 rpm 750 rpm
Standby eKW Prime eKW Cont. eKW Standby kVA Prime kVA Cont. kVA 900 rpm 750 rpm
2000 - 5320 1820 - 4840 1650 - 4400 2163 - 5725 1963 - 5200 1775 - 4725 Standby eKW Continuous eKW Standby kVA Continuous kVA
- 1145-3480 - 7375
720 rpm
Standby eKW Prime eKW Cont. eKW 720 rpm
1680-4440 1524-4040 1375 - 3660 Standby eKW Continuous eKW
- 5900
DIESEL RATING DEFINITIONS:
Standby — Output available with varying load for the duration of the interruption of the
normal source power. Standby power in accordance with ISO8528. Fuel stop power in GAS RATING DEFINITIONS:
accordance with ISO 3046/1, AS2789, DIN6271, and BS5514. Standby — These ratings are applicable for supplying continuous power (at variable load)
Prime — Output available with varying load for an unlimited time. Prime power in in the event of a utility power failure. No overload is permitted on these ratings. Natural
accordance with ISO8528. 10% overload power in accordance with ISO 3046/1, AS2789, gas ratings have been established on natural gas with net calorific Low Heat Value (LHV)
DIN6271, and BS5514 available on request. of approximately 35.6 mJ/m3 (905 Btu/ft3) and 80 mn.
Continuous — Output available without varying load for an unlimited time. Continuous Continuous — Output available without varying load for an unlimited time. Continous
power in accordance with ISO 8528, ISO 3046/1, AS2789, DIN6271, and BS5514. power in accordance with ISO 8528, ISO 3046/1, AS2789, DIN6271, and BS5514. Natural
Ratings are based on SAE J1995 standard conditions. These ratings also apply at gas ratings have been established on natural gas with net calorific Low Heat Value (LHV)
ISO 3046/1, DIN6271, and BS5514 standard conditions. of approximately 35.6 mJ/m3 (905 Btu/ft3) and 80 mn.
CM SERIES RATINGS
Gen Set Continuous
Model 60 Hz 50 Hz
900 rpm 1000 rpm
6CM20 TA 980 eKW 1368 kVA
8CM20 TA 1300 eKW 1825 kVA
9CM20 TA 1470 eKW 2050 kVA
See us at
www.Cat-engines.com
OLYMPIAN® GENERATOR SETS
NATURAL GAS RATINGS DIESEL RATINGS
60 Hz 3 Phase Output 50 Hz 3 Phase Output 60 Hz 3 Phase Output 50 Hz 3 Phase Output
3600 rpm 3000 rpm 3600 rpm 3000 rpm
Standby eKW Prime eKW Standby kVA Prime kVA Standby eKW Prime eKW Standby kVA Prime kVA
20-25 - 30 - 24.7 - 14-40 -
1800 rpm 1500 rpm 1800 rpm 1500 rpm
Standby eKW Prime eKW Standby kVA Prime kVA Standby eKW Prime eKW Standby kVA Prime kVA
12-100 11-85 15-22 12.5-19 8-200 7.3-180 12.5-275 11.4-250
60 Hz Single Phase Output 50 Hz Single Phase Output 60 Hz Single Phase Output 50 Hz Single Phase Output
3600 rpm 3000 rpm 3600 rpm
Standby eKW Prime eKW Standby kVA Prime kVA 1500 rpm
Standby eKW Prime eKW
17.5-25 - 24 - Standby kVA Prime kVA
24 -
10-105 9.1-96
1800 rpm 1500 rpm 1800 rpm
Standby eKW Prime eKW Standby kVA Prime kVA Standby eKW Prime eKW
10-100 9-85 11.8-17.5 10-14.8 8-105 7.3-96
60 Hz 3 Phase Output 60 Hz 3 Phase Output
Outside North America Outside North America
3600 rpm 3600 rpm
Standby eKW Prime eKW Standby eKW Prime eKW
24 - 24.9 -
1800 rpm 1800 rpm
Standby eKW Prime eKW Standby eKW Prime eKW
15-25 13.5-21.2 8-200 7.3-180
60 Hz Single Phase Output 60 Hz Single Phase Output
Outside North America Outside North America
3600 rpm 1800 rpm
Standby eKW Prime eKW Standby eKW Prime eKW
25 - 8-113 7.3-100
1800 rpm RATING DEFINITIONS:
Standby eKW Prime eKW Standby — Applicable for supplying continuous electrical power (at variable load) in the
15-23 13-20 event of a utility power failure. No overload is permitted on these ratings. The generators
on models D20L2, D20L2S, D20P1-D200P4 and D20P1S0D100P2S are peak rated (as
defined in ISO 8528-3)
LP GAS RATINGS Prime — These ratings are applicable for supplying continuous electrical power (at
variable load) in lieu of commercially purchased power. There is no limitation to the
60 Hz 3 Phase Output 50 Hz 3 Phase Output annual hours of operation and this model can supply 10 percent overload power for 1
3600 rpm 3000 rpm hour in 12 hours.
Standby eKW Prime eKW Standby kVA Prime kVA
20-25 - 30 - RATING DEFINITIONS:
Outside North America
1800 rpm 1500 rpm
Standby — (for GEL 3000/3600 rpm models and GEP models with suffix “E”):
Standby eKW Prime eKW Standby kVA Prime kVA These ratings are applicable for supplying continuous power (at variable load) in the
12-80 11-68 16.5-25 14-22 event of a utility power failure. No overload is permitted on these ratings. The alternators
on these models are peak continuous rated (as defined in ISO8528-3) at 25° C (77° F).
60 Hz Single Phase Output 50 Hz Single Phase Output
Prime — (for GEL 1500/1800 rpm models and all other GEP models): These ratings are
3600 rpm 3000 rpm
applicable for supplying continuous electrical power (at variable load) in lieu of
Standby eKW Prime eKW Standby kVA Prime kVA commercially purchased power. There is no limitation to the annual hours of operation
17.5-25 - 24 - and GEP models can supply 10% overload power for 1 hour in 12 hours.
RATING DEFINITIONS:
Standby — These ratings are applicable for supplying continuous power (at variable load)
in the event of a utility power failure. No overload is permitted on these ratings. Natural
gas ratings have been established on natural gas with net calorific value of
approximately 36.8 mJ/m3 (988 Btu/ft3).
Prime — These ratings are applicable for supplying continuous electrical power (at
variable load) in lieu of commercially purchased power. There is no limitation to the
annual hours of operation and this model can supply 10 percent overload power for 1 See us at
hour in 12 hours.
www.Cat-engines.com
CAT INDUSTRIAL DIESEL ENGINES
INTERMITTENT RATINGS
Model bkW bhp Max rpm
3003 15/18 20/24 3600
3011C 15/20 20/27 3000
RATING DEFINITIONS:
3013C 24 32 2800
Rating conditions:
3014C 32 43 2800 All ratings are based on SAE J1349 standard ambient conditions of 100 kPa (29.6 in
3024C 38 51 3000 Hg), 30% relative humidity and 25°C (77°F). Ratings also apply at AS1501, BS5514,
DIN6271 and ISO3046/1 standard conditions.
3024CT 48 60 3000
C Rating (Intermittent):
3044C/CT 43/60 58/80 2600 • For service where power and/or speed are cyclic. Horsepower and speed
3054C 50/60 67/81 2200 capability of the engine can be utilized for one uninterrupted hour followed by
one hour of operation at or below the A rating.
3054CT 69/92 92/115 2400
• Time at full load not to exceed 50% of the duty cycle.
3054C/E 83/91 111/142 2300 • Typical application examples include agriculture tractors, off-highway truck, fire
3056C/E 92/131 114/175 2500 pumps, blast hole drills, rock crushers, kill pumps, oil field hoisting, and
workover rigs.
Electronically controlled/governed.
1
* ATAAC — Air-to-Air Aftercooled
Also approved to CANMET/SCA (Cert. No. 1099).
3
See us at
www.Cat-engines.com
CAT INDUSTRIAL DIESEL ENGINES CONT.
CAT DIESEL ENGINES FOR FIRE PUMP PACKAGES
1460 rpm 1750 rpm 1900 rpm 2100 rpm 2200 rpm 2300 rpm
Model No. of Cyl bkW bhp bkW bhp bkW bhp bkW bhp bkW bhp bkW bhp
3406 T I6 183 247 218 292 233 312 246 330 - - 261 350
3406 T I6 242 325 276 370 280 375 280 375 - - - -
3406 TA I6 224 300 313 420 317 425 321 430 - - 339 455
3406 TA I6 - - 343 460 343 460 360 483 - - - -
3508 TA V8 709 950 794 1065 - - - - - - - -
3512 TA V12 1067 1430 1193 1600 - - - - - - - -
3516 TA V16 1417 1900 1480 1985 - - - - - - - -
1750 rpm 2100 rpm 2300 rpm 2400 rpm 2800 rpm 3000 rpm
Model No. of Cyl bkW bhp bkW bhp bkW bhp bkW bhp bkW bhp bkW bhp
3126 TA I6 145 195 175 235 186 250 190 255 201 270 149 200
See us at
www.Cat-engines.com
CAT OIL AND GAS ENGINES
RATING DEFINITIONS:
The horsepower and speed capability of the engine which can be used to power high pressure
well servicing equipment.
See us at
www.Cat-engines.com © 2003 Caterpillar