You are on page 1of 1

No.

Dokumen :
PT. PLN (Persero) PEMBANGKITAN SUMATERA BAGIAN SELATAN
SEKTOR DALKIT BANDAR LAMPUNG PERFORMANCE TEST DAN VALVE STEM FREE TEST UNIT 1 Revisi :
PUSAT LISTRIK TANGGAMUS Tanggal :
PLTP ULU BELU Hari/ Tanggal : Sabtu, 11 September 2021 Halaman :

KOMISIONING Valve Stem Free Test


Beban 75% (41,25 MW) Beban 100% (55 MW)
Beban 75 % Beban 100 % (45 MW)
NO PARAMETER Satuan KETERANGAN
41, 25 MW 55 MW PUKUL
10:00 - 11.00 WIB
Sabtu, 28 Juli 2012 Minggu, 05 Agustus 2012 11.30 12.00 12.30 13.00

1 Generator Aktif Power (Beban Power) MW 41,10 54,90 41,50 41,50 53,60 53,60
2 Generator Aktif Power (Beban Power) KW 41.100 54.900 41.500 41.500 53.600 53.600
3 Pemakaian Sendiri Sentral (PS per Unit) MW 2,050 2,050 2,015 2,046 2,064 2,049
4 Persentase Pemakaian Sendiri (PS per Unit) % 4,99 3,73 4,86 4,93 3,85 3,82
5 Main Steam Pressure (Turbine Inlet Pressure) bar-g 6,68 6,54 6,36 6,25 6,23 6,27
6 Main Steam Temp (Turbine Inlet Temperature) °C 168,3 168,5 167,1 166,9 166,6 166,6
7 Main Steam Entalphy Vapor *) KJ/Kg 2.760,76 2.759,86 2.758,66 2.757,91 2.757,77 2.758,05 Steam Property P only (Vapor)
8 Main Steam Entrophy Vapor*) KJ/Kg-K 6,7229 6,7300 6,7395 6,7454 6,7465 6,7443 Steam Property P only (Vapor)
9 Condenser Temperature (Turbine Outlet Temperature) °C 38,70 41,20 43,80 43,60 44,70 45,00
10 Condenser Pressure (Condenser Vacuum Pressure) bar-a 0,069 0,078 0,087 0,084 0,091 0,092
11 CT Inlet Water Temperature (Condensate Water Temperature) °C 37,80 40,00 43,50 43,30 44,30 44,60
12 Condensate Water Entalphy Liquid *) KJ/Kg 157,72 166,91 181,54 180,71 184,88 186,14 Steam Property T only (Liquid)
13 Condensate Water Entalphy Vapor *) KJ/Kg 2.570,95 2.575,42 2.580,05 2.579,70 2.581,65 2.582,19 Steam Property T only (Vapor)
14 Condensate Water Entrophy Liquid*) KJ/Kg-K 0,541 0,570 0,617 0,614 0,627 0,631 Steam Property T only (Liquid)
CATATAN :
15 Condensate Water Entrophy Vapor*) KJ/Kg-K 8,3004 8,2585 8,1935 8,1971 8,1788 8,1734 Steam Property T only (Vapor)
Grafik MCV A & B
16 Main Steam Flow Kg/h 278.000 358.000 288.300 287.500 355.500 356.100 Hasil Steam Flow X 1000
terlampir
17 Main Steam Flow Kg/s 77,22 99,44 80,08 79,86 98,75 98,92
18 Cooling Tower Inlet Water Temperature (CW Inlet Temperature) °C 37,80 40,00 43,50 43,30 44,30 44,60
19 Main Cooling Water Temperature (CW Outlet Temperature) °C 26,4 25,7 30,60 30,30 28,80 29,10
20 CW Outlet Entalphy *) KJ/Kg 110,07 107,14 127,63 126,37 120,10 121,36 Steam Property T only (Liquid)
21 Make Up Flow Cooling Tower t/h 0 0 0 0 0 0
22 Steam Rate Kg/h/kW 6,76 6,52 6,95 6,93 6,63 6,64
23 Turbine Heat Rate KJ/kWh 1283,90 1202,72 1240,79 1234,60 1168,09 1168,35
24 ΔT Cooling Water Condenser °C 11,4 14,3 12,9 13 15,5 15,5
25 Condenser Cooling Water Flow m3/h 12.414 12.415 10.567 10.815 10.530 10.462
26 Condenser Heat Load KJ/h 591.551.928 742.094.210 569.793.774 587.687.100 682.238.700 677.832.980
27 Efisiensi Condenser % 81,75 79,95 76,68 79,31 74,58 74,00
28 Entalphy Isentropik KJ/Kg 2080,33 2096,58 2119,77 2120,41 2127,02 2128,17
29 Daya Turbin Isentropik MW 52,54 65,96 51,16 50,91 62,29 62,31 1 KW = 3600 KJ/h
30 Efisiensi Silinder Turbin (isentropik) % 78,22 83,23 81,11 81,51 86,05 86,03
*) Perhitungan Entalphy & Entrophy menggunakan aplikasi android steam property
CATATAN : Untuk Performance Test Beban 75% & 100% Cooling Tower Fan di Operasika semua Ulubelu, 11 September 2021

keterangan :

SETIAWAN ADI SAPUTRA