You are on page 1of 6

Slab Properties

fc' 21 MPa
fy 276.5 MPa
As 200 mm2
h 100 mm
d 75 mm
ln 4.05 m
l1 3.55 m
Es 200000 MPa
β1 0.85
Fiber Propeties
tf 0.167 mm
Ef 232000 MPa
εfu 0.015
Loadings
DL 4.602943 kPa
Slab Selfweight 2.4 kPa
Fiber Selfweight 0.002943 kPa
Floor Finish 1.1 kPa
Ceiling 0.1 kPa
Partition 1 kPa
LL 1.9 kPa
Basic Floor 1.9 kPa
service construction
qu 8.5635316 kPa 6.502943 11.52
Mo 62.330601387 kN-m 47.33238 83.84958
0.35Mo 21.815710485 kN-m 16.56633 29.34735
Mu 10.773190363 kN-m/m 8.180906 14.49252
Compute φMni of unstrengthened section
φMni = φAsfy(d-a/2)
T=C
Asfy = 0.85fc'ab
a 3.0980392157 mm
φMni 3.6556552941 kN-m
Assuming a failure strain of 0.8εfu for composite, and a lever arm of 0.90h, estimate area of composite required

Af_reqd

Af_reqd 31.562788549 mm2


wf 188.99873383 mm
say 190 mm
Af 31.73 mm2
Obtain properties of uncracked section and cracking moment
Ec = 4700*sqrt(fc')
Ec 21538.105766 MPa
yave = h/2
yave 50 mm
Ig = bh3/12
Ig 83333333.333 mm4
fr = 0.62*sqrt(fc')
fr 2.8411969309
Mcr = [Ig/(h-yave)]*fr
Mcr 4.7353282181 kN-m
Compute of cracked unstrengthened section
n = Es/Ec
n 9.2858676696
b(kd) /2 = nAs(d-kd)
2

kd 14.936430118 mm
Icr = b(kd)3/3 + nAs(d-kd)2
Icr 7810756.7714 mm4
Compute fc , fs , εbi & δ for the loads present at the installation
Mi 14.49252 kN-m
fc = (Mi/Icr)*kd
fc 27.713897456 MPa > 0.45fc' 9.45 use this as allowable fc'
εc = fc/Ec Mallowed 4.94172
εc 0.0012867379
fs = (Mi/Icr)(d-kd)n
fs 1034.8667316 MPa > 0.8fy 221.2 use this as allowable fy
εs = fs/Es Mallowed 3.097737
εs 0.0051743337
εbi = εc*[(h-kd)/kd]
εbi 0.0073280242
Compute φMn of strengthened section , assume failure is initiated by concrete:
nEftf (English Units)
Ef 33659256 psi
tf 0.0065748031 in
nEftf 221302.98236 < 1200000
km1 0.907790424
km2 2.7112151567
km 0.907790424
0.85fc'bβ1c = Asfy + AfEf0.003[(h-c)/c]
c 13.208712933 mm
εf = 0.003*[(h-c)/c]
εf 0.019712281
εfe = kmεfu
εfe 0.0136168564 OK

ano 8.7136460356 mm
ayes 11.227405993 mm
a 8.7136460356 mm
Mn_no 15.498950453 kN-m
Mn_yes 17.533381988 kN-m
Mn 15.498950453
φMn 13.949055408 > Mu OK
Long term effects with a reduction factor of 0.85 on maximum strain
εfu = 0.85εfu
εfu 0.01275
ano 8.3561535014 mm
ayes 11.227405993 mm
a 8.3561535014
Mn_no 15.469125722
Mn_yes 17.533381988
Mn 15.469125722
φMn 13.92221315 > Mu OK
Check for ductility
εf 0.019712281
εs = (εf + εbi)[(d-c)/(h-c)]
εs 0.019251417 > 0.002765 2εy OK
Check for allowable stresses at working loads
Mn 8.180905511
nf = Ef/Ec
nf 10.771606497
b(kd)2/2 = nAs(d-kd) + nfAf(h-kd)
kd 16.55652406 mm
Icr = b(kd)3/3 + nAs(d-kd)2 + nfAf(h-kd)2
Icr 10236024.302 mm4
fc 13.232418654 MPa 0.45fc' 9.45
εc 0.0006143724
fs 433.73912246

Ie 24411822.397
Check for deflection
2
δ = 5ML /48EcIe
δ 26.584744026 NG L/800 5.0625 mm
posite required
s allowable fc'

s allowable fy