S7-300 Module data

Digital output module SM 322;DO 8 x AC 120/230 V/2 A; (6ES7322-1FF01-0AA0)

Digital output module SM 322;DO 8 x AC 120/230 V/2 A; (6ES7322-1FF01-0AA0)

Order number: "Standard module"


6ES7322-1FF01-0AA0

Order number: "SIPLUS S7-300 module"


6AG1322-1FF01-2AA0

Properties
Properties of SM 322; DO 8 x AC 120/230 V/2 A:
• 8 outputs, fused and electrically isolated in groups of 4

• Output current 2 A

• Rated load voltage 120/230 VAC

• Suitable for AC solenoid valves, contactors, motor starters, FHP motors and signal lamps.

• Group error display (SF)

This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the
completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to third parties.
3/17/2021
S7-300 Module data
Digital output module SM 322;DO 8 x AC 120/230 V/2 A; (6ES7322-1FF01-0AA0)

Wiring and block diagram of SM 322; DO 8 x AC 120/230 V/2 A

① Channel number
② Status display - green
Error LED - red
③ Backplane bus interface
④ Optotriac

SM 322; DO 8 x AC 120/230 V/2 A - Technical specifications

Technical specifications

Dimensions and weight

Dimensions W x H x D (mm) 40 x 125 x 117

Weight ca. 275 g

Module-specific data

Supports isochronous mode no

Number of outputs 8

This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the
completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to third parties.
3/17/2021
S7-300 Module data
Digital output module SM 322;DO 8 x AC 120/230 V/2 A; (6ES7322-1FF01-0AA0)

Technical specifications

Cable length max. 600 m


• unshielded max. 1000 m
• shielded

Voltages, currents, electrical potentials

Rated load voltage L1 120/230 VAC


• Maximum frequency range 47 Hz to 63 Hz

Total current of outputs


(per group)

• horizontal mounting position max. 4 A


to 40 °C max. 2 A
to 60 °C

• vertical mounting position max. 2 A


to 40 °C

Electrical isolation yes


• between channels and the backplane bus yes
• between channels 4
in groups of

Maximum potential difference

• between Minternal and outputs 230 VAC

• between outputs of different groups 500 VAC

Isolation test voltage 1500 VAC

Current consumption max. 100 mA


• from the backplane bus max. 2 mA
• from load voltage L1 (no-load)

Power loss of the module typ. 8.6 W

Status, interrupts, diagnostics

Status display green LED per channel

Interrupts none

Diagnostic functions yes


• Group error display red LED (SF) 2)

Actuator selection data

Output voltage
min. L1 (-1.5 V)
• "1" signal
min. L1 (-8.5 V)
― At maximum current
― At minimum current

This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the
completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to third parties.
3/17/2021
S7-300 Module data
Digital output module SM 322;DO 8 x AC 120/230 V/2 A; (6ES7322-1FF01-0AA0)

Technical specifications

Output current
AC 2 A1)
• "1" signal
10 mA to 2 A
Rated value
10 mA to 1 A
permissible range at 0 °C to 40 °C
max. 20 A (max. 1 AC cycle)
permissible range at 40 °C to 60 °C
Maximum inrush current (per group)

• "0" signal (residual current) max. 2 mA

Output delay (resistive load)

• "0" to "1" transition max. 1 AC cycle

• "1" to "0" transition max. 1 AC cycle

Minimum load current 10 mA

Zero transition max. 60 V

Size of the motor starter max. size 5 to NEMA

Lamp load max. 50 W

Wiring two outputs in parallel

• for redundant load control supported (only outputs of the same group)

• for performance increase not supported

Control of a digital input supported

Switching frequency max. 10 Hz


• with resistive load max. 0.5 Hz
• with inductive load to IEC 947-5-1, AC 15 max. 1 Hz
• with lamp load

Short-circuit protection of the output Fuse, 8 A/250 V; per group

• Fuse-tripping current min. 40 A

• Response time max. 300 ms

Replacement fuses 8 A fuse/fast-blow


• Wickman 194-1800-0
• Schurter SP001.1013
• Littlefuse 217.008

Fuse holder 653 07


• Wickman

Wiring of the actuators using a 20-pin front connector

1) The load current must not be half-wave


2) Possible errors:
- no load voltage

This document constitutes a free excerpt compiled by the user himself/herself from the documentation provided by Siemens for this product. Siemens disclaims all liability for the
completeness of this document. It shall only be used for the user's own internal purposes. It shall not be passed on to third parties.
3/17/2021
S7-300 Module data
Digital output module SM 322;DO 8 x AC 120/230 V/2 A; (6ES7322-1FF01-0AA0)

- defective fuse