45 MM

LENGTH-350MM

80MM

LENGTH-500MM

Values (mm) of PL, PW,A1,A2,A3, T is

PL=177

PW=152

T=38

A1,A2,A3-for SDH amplitude check using 0◦ probe also, then SDH position check also.

In T/4 SDH, POSTION 1=9.5, POSITION 2=19.0

In T/2 SDH, POSTION 1=19.0, POSITION 2=19.0

In 3T/4 SDH, POSTION 1=28.5, POSITION 2=19.0

This values are conformed by manual measurement (Value in mm)