You are on page 1of 2
Tank Configurations - Type 3 A TANK WITHIN A TANK TECHNIQUES SAME AS TYPE 1 —— HOWEVER, WHEN THE SECOND HATCH IS OPENED, TESTER MUST IMMEDIATELY | SAMPLE THE INNER ATMOSPHERE Tank Configurations - Type 4 BAFFLED TANK - ONE ACCESS HATCH TECHNIQUES SAME AS TYPE 1 HOWEVER, TANK IS NOT DESIGNED TO BE WELL VENTILATED. ‘THE TESTER MUST ENTER EACH INDIVIDUAL SEGMENT (BAY) OF ‘THIS TANK AND TEST THE NEXT SEGMENT 110 Tank Configurations - Type 1 DETERMINE RESPONSE TIME by SAMPLE LINE MUST REACH TO BOTTOM OF TANK ALL LEVELS OF THE TANK MUST BE SAMPLED INSTRUMENT MUST BE OBSERVED FOR RESPONSE TIME EVEN AFTER ‘SAMPLE LINE HAS BEEN REMOVED FROM TANK Tank Configurations - Type 2 IRREGULAR SHAPED TANK TECHNIQUES SAME AS TYPE 1 BUT TESTER MUST ENTER SPACE IN ORDER TO REACH TANK LOW POINTS 109

You might also like