GasAlert Extreme To clear TWA, STEL, and maximum (MAX) gas exposures

Quick Reference Operations Key readings, press and hold C for 6 seconds.
CALIBRATION:
ON: Press A. Audible/visual/vibrator alarms activate. The current 1. In a clean atmosphere, press C and E simultaneously and
TWA, STEL, low, and high alarm setpoints display. A self-test hold for 5 seconds. The LCD displays CAL.
performs during the start-up sequence. 2. flashes while the detector zeroes the gas sensor.
OFF: Press A and hold for 5 seconds to deactivate the detector. 3. Enter the span setting and press C to confirm.
BACKLIGHT: In alarm (auto), in low light (auto), and on demand 4. When flashes, connect the gas cylinder and apply gas at a
(press any key in low light conditions to reactivate). flow rate of 500-1000 ml/min. The detector beeps three times at
GAS ALARMS: GasAlert Extreme is equipped with TWA, STEL, the end of the span stage. Remove the calibration gas.
low, and high alarms. Audible/visual/vibrator alarms activate, 5. Press E or D to change the next calibration due date and
readout advises gas hazard present in ppm or % vol, and alarm press C to save.
icons light advising of alarm level. 6. Press E or D to change the alarm setpoint or press C to skip
LOW BATTERY ALARM: flashes and audible/visual alarms to the next setpoint. Press C to save a changed setpoint. The
pulse. Change battery in a non-hazardous atmosphere only. detector beeps and vibrates four times at the end of calibration.
VIEW TWA, STEL, and PEAK (MAX) EXPOSURES: Press and PASS CODE PROTECT: Enter the pass code when prompted.
hold C and D. TWA, STEL, and peak (MAX) exposures display APPROVALS:

j ATEX X g IECEx
in ppm or % vol. and
TWA = accumulated exposure to toxic gases based on an 8-hour others
work day (O2: not applicable) For a full understanding of the GasAlert Extreme’s features,
STEL = short-term exposure limit to gas based on a operation, calibration, and service, read the user manual.
15-minute period (O2: not applicable)
To contact BW Technologies by Honeywell call:
PEAK (MAX) = maximum concentration encountered*.
*For oxygen, it is the highest and lowest concentration encountered. USA: 1-888-749-8878 Canada: 1-800-663-4164
Leave the detector on for the entire work shift. TWA, STEL, and Europe: +44 (0) 1295 700300 Other: 1-403-248-9226
maximum (MAX) concentration readings reset if the power is lost.