You are on page 1of 64

Service Manual – CI200 REV NO :

CI200 Series

Service Manual

LAST Rev. NO :

LAST Rev. Date : 2010. 03. 22

1
Service Manual – CI200 REV NO :

Table of Contents
1. Proper Operation......................................................................................................................................................................... 3
1.1 Warning ........................................................................................................................................................................... 3
1.2 Attention .......................................................................................................................................................................... 4
2. Classification ................................................................................................................................................................................ 5
2.1 Display ................................................................................................................................................................................ 5
2.2 Key Fubction ...................................................................................................................................................................... 7
3. Weighing Mode ............................................................................................................................................................................ 8
3.1 Led Type ............................................................................................................................................................................. 8
3.2 Lcd Type ........................................................................................................................................................................... 10
4. System Mode .............................................................................................................................................................................. 12
5. Set Mode ..................................................................................................................................................................................... 19
6. Test Mode ................................................................................................................................................................................... 35
7. Weight Setting (Calibration) Mode .......................................................................................................................................... 38
8. Servicing & Parts Replacement Mode ..................................................................................................................................... 44
9. Option Installing Mode ............................................................................................................................................................. 45
10. Update Mode ............................................................................................................................................................................ 46
11. Exploded Mode ........................................................................................................................................................................ 47
12. Revision .................................................................................................................................................................................... 60
13. Schemetic.................................................................................................................................................................................. 61

2
Service Manual – CI200 REV NO :

1. Proper Operation / Introduction


PRECAUTIONS

3
Service Manual – CI200 REV NO :

4
Service Manual – CI200 REV NO :

2. Classification
DISPLAY AND KEYBOARD

 CI200-A(LED)

 CI201-A(LCD)

5
Service Manual – CI200 REV NO :

 CI200-S

 CI200-SC

6
Service Manual – CI200 REV NO :

 KEY FUNCTION
Function Key
* Some functions can be defined to the needs.
(The function set at F17 in the Set Mode will be operated.)

* Some functions can be defined to the needs.


(The function set at F18 in the Set Mode will be operated.)

Number Key
* It enters 1 in the input mode.
* It sets the weight display near zero point to 0.
( A range of 2%, 5%, 10%, 20% and 100% can be selected.)
* Long press to enter the test mode.
* It enters 2 in the input mode.
* Each press after setting up the tare displays the gross weight and the net weight in turn. (The displayed weight is the
net weight when the net weight lamp is one, but the displayed weight is the gross weight when the net weight lamp is
off.)
* Long press to enter the setup mode.
* It enters 3 in the input mode.
* Use it to weigh with the tare.
* The current weight is memorized as the tare by pressing the key.
* Press the key when the load tray is empty to release the tare.
* Long press to enter the system selection mode.(CI-201A Only)
* It enters 4 in the input mode.
* Use it to check the subtotal (partial summation).
* Long press to enter the system weight setup mode.
(CI-201A Only)
* It enters 5 in the input mode.
* Use it to check the grand total (entire summation).

* It enters 6 in the input mode.


* Use it to check the weighing count.

* It enters 7 in the input mode.


* Use it for the manual print. (manual print key)
(Print format can be changed in the Set Mode.)
* It enters 8 in the input mode.
* Use it to fix the shaking weight.

* It enters 9 in the input mode.


* Use it to check the remaining capacity of battery.

* Use it to correct any wrong input while entering data.


* Use it to enter a decimal point (.) in the weight setup mode and weighing mode.

* It enters 0 in the input mode.


* Use it to register an item number. (0 ~ 19)

* Use it to save the current status and exit from the weight setup mode, Set Mode and test mode.
* Use it to check the current weight value in PCS and percent mode. (CI-201A Only)

Double Key

+ * Use it to print the subtotal.

+ * Use it to print the grand total.


* Use it for the tare key.
* If the tare is known, enter it using the numeric keys.
(If the remaining value occurs when the input value is divided into the minimum unit, the value is rounded and
+ entered.)
The key tare function cannot be used during the PCS and percent functioning.

7
Service Manual – CI200 REV NO :

3. Weighing Mode

3-1. LED TYPE


(1). Zeroing Function (used when the zero point changes)

■ Range of zero point: within a range set in F13

Zero chanced. Press Zero Key to set the zero lamp on and 0.

(2). Tare Function (used for weighing with a container)


■ Maximum tare set range: maximum weight
* Caution: the weight including the tare cannot exceed the maximum weight.

Put a container on the load tray. Press the tare key. Put an object on the load tray.
(Container weight: 10kg) (Tare is saved.) (Net weight: 20kg)

■ If you want to know the total weight

Press the 'total * net weight' key (the value of object's weight + tare is displayed.)

■ If you want to know the net weight

Press the 'total * net weight' key (the value of object's weight is displayed.)
Remove the container and object from the load tray to display the saved tare.

■ If the tare is removed

Remove the container and object from the load tray, if the saved tare is only displayed (picture on the left).
Then press the tare key (picture on the right)

8
Service Manual – CI200 REV NO :

(3). Hold Function (used for weighing moving objects)


■ Ordinary Hold Function (hold function is performed when the hold key is pressed.)

Put an object on the load tray. Press the hold key. Hold message is The hold weight is calculated for
displayed for a second. about 3~5 seconds.

The hold weight is displayed.


It returns to the normal status and the hold lamp is turned off
if you empty the load tray or press the hold key to release the held
weight value.

■ Automatic hold function (the hold function is performed by automatically calculating the maximum weight of moving objects.)

Empty the load tray. The weight on the load tray is The maximum value is displayed
displayed. with 'HOLD'.

■ It returns to the normal status and the hold lamp is turned off if you empty the load tray or press the hold key to release the held weight value.

※ Note. The hold function carries out operations according to the set value of F10.

9
Service Manual – CI200 REV NO :
2. LCD TYPE

(1). Zeroing Function (used when the zero point changes)


■ Range of zero point: within a range set in F13

Zero chanced.. Press Zero Key to set the zero


lamp on and 0.

(2). Tare Function (used for weighing with a container)


■ Maximum tare set range: maximum weight
* Caution: the weight including the tare cannot exceed the maximum weight.

Put a container on the load tray. Press the tare key. Put an object on the load tray.
(Container weight: 10kg) (Tare is saved.) (Net weight: 20kg)

■ If you want to know the total weight

Press the 'total * net weight' key (the value of object's weight + tare is displayed.)

■ If you want to know the net weight;

Press the 'total * net weight' key (the value of object's weight is displayed.)
Remove the container and object from the load tray to display the saved tare.

■ If the tare is removed

Remove the container and object from the load tray, if the saved tare is only displayed (picture on the left).
and press the tare key (picture on the right)

(3). Hold Function (used for weighing moving objects)


10
Service Manual – CI200 REV NO :
■ Ordinary Hold Function (hold function is performed when the hold key is pressed.)

Put an object on the load tray. Put an object on the load tray. The hold weight is calculated for
about 3~5 seconds

The hold weight is displayed.


It returns to the normal status and the hold lamp is turned off
if you empty the load tray or press the hold key to release the held
weight value.

■ Automatic hold function (the hold function is performed by automatically calculating the maximum weight of moving objects.)

Empty the load tray The weight on the loa d tray is The maximum value is
displayed. displayed with 'HOLD'

■ It returns to the normal status and the hold lamp is turned off if you empty the load tray or press the hold key to release the held weight value.
※ Note. The hold function carries out operations according to the set value of F10.

11
Service Manual – CI200 REV NO :
4. System Mode
4-1. How to Enter the System Mode

Step Display Screen and Key Input Load Tray Descriptions

1 Press key for about 3 seconds in the weighing mode. Empty


Screen display: “1. PCS” characters are blinking after
2
“SYSTEM” is displayed.
If key is pressed, “1. PCS” characters are blinking.
Select the mode to
3 If key is pressed, “2. PER” characters are blinking. which you want to
If key is pressed, “3. WGT” characters are blinking. move.

4 If key is pressed, the selected mode is set.

Weighing Mode (I)


Initial Screen Descriptions

Weighing Mode

Counting Mode (II)


Initial Screen Descriptions

Counting Mode

퍼센트 모드 (Ⅲ)
Initial Screen Descriptions

Percent Mode

12
Service Manual – CI200 REV NO :

4-2. PCS MODE


4-2-1. PCS MODE Sample Input Method

Step Display Screen and Key Input Load Tray Descriptions


1 Press key for about 3 seconds in the PCS Mode. Empty

2 Screen display: “1.SAMPL” characters are blinking.


Select the input
If key is pressed, “1. SAMPL” characters are blinking.
3 method as
If key is pressed, “2. WEIGH” characters are blinking. desired.

4 Press + keys.

Screen display: A/D value is displayed after “SAMPLE” -> Put samples on
5 Sample
“LoAd” is shown.(Wait until the weight is stable.) the load tray

Save sample
6 Press key Sample
weight
7 Screen display: “SUCCES” -> “NUMBER” is displayed. Sample

Enter the number of samples using ~ keys, and then press


8 key. Sample
(Ex) If 10kg (sample) and 10 pieces, then the unit weight becomes 1kg.
9 Screen display: It moves to PCS Mode after displaying “End”. Sample

Note 1. The current weight is displayed when key is pressed during operating “1. PCS MODE”.

Note 2. If the value of 1 PCS is smaller than 0.7 divisions of maximum resolution capacity when the number of samples is entered, Err-21 is displayed.

4-2-2. PCS Mode Direct Input Method

Step Display Screen and Key Input Load Tray Descriptions


1 Press key for about 3 seconds in the PCS Mode. Empty

2 Screen display: “1.SAMPL” characters are blinking.


Select the input
If key is pressed, “1. SAMPL” characters are blinking.
3 method as
If key is pressed, “2. WEIGH” characters are blinking. desired.

4 Press + keys.

Screen display: After “WEIGHT” is displayed, “0.000 KG” is Weight input


5
displayed. mode

Save sample
6 Enter the weight of PCS using ~ keys, and then press key. weight
7 Screen display: It moves to PCS Mode after displaying “End”.

Note 1. If key is pressed during operations in the PCS MODE, it shows the current weight for 3 seconds and then returns to the PCS MODE.

Note 2. If the value of Piece Weight to a function key (F17 or F18), you may confirm the unit weight of 1 PCS.

13
Service Manual – CI200 REV NO :
4-3. PERCENT MODE

4-3-1. Percent Mode Sample Input Method

Step Display Screen and Key Input Load Tray Descriptions


1 Press key for about 3 seconds in the Percent Mode. Empty

2 Screen display: “1.SAMPL” characters are blinking.


Select the input
If key is pressed, “1. SAMPL” characters are blinking.
3 method as
If key is pressed, “2. WEIGH” characters are blinking. desired.
4 Press + keys.
Screen display: A/D value is displayed after “SAMPLE” -> “LoAd” is
Put samples on
5 shown. Sample
the load tray
(Wait until the weight is stable.)
Save sample
6 Press key Sample
weight
7 Screen display: “SUCCES” -> “NUMBER” is displayed. Sample

Enter the number of samples using ~ keys, and then press


8 key. Sample
(Ex) If 10kg (sample) and 10 pieces, then the unit weight becomes 1kg.
9 Screen display: It moves to Percent Mode after displaying “End”. Sample

Note 1. The current weight is displayed when key is pressed during operating in the Percent Mode.

Note 2. If the value of 1 PCS is smaller than 0.7 divisions of maximum resolution capacity when the number of samples is entered, Err-21 is displayed.

4-3-2. Percent Mode Direct Input Method

Step Display Screen and Key Input Load Tray Descriptions


1 Press key for about 3 seconds in the PCS Mode. Empty

2 Screen display: “1.SAMPL” characters are blinking.


Select the input
If key is pressed, “1. SAMPL” characters are blinking.
3 method as
If key is pressed, “2. WEIGH” characters are blinking. desired.

4 Press + keys.

Screen display: After “WEIGHT” is displayed, “0.000 KG” is Weight input


5
displayed. mode

Save sample
6 Enter the weight of 100% using ~ keys, and then press key. weight
7 Screen display: It moves to Percent Mode after displaying “End”.

Note 1. If key is pressed during operations in the Percent MODE, it shows the current weight for 3 seconds and then returns to the PCS Mode.

Note 2. If the value of Piece Weight to a function key (F17 or F18), you may confirm the unit weight of 1 PCS.

14
Service Manual – CI200 REV NO :
4-4. General Function Descriptions
4-4-1. Item Number (Unique Number of Weighing Item: ID) Input Method

Load
Step Display Screen and Key Input
Tray
Descriptions

key “Meaning the value of the


1 Press
Screen display: “ID = XX” current item number”

2 Enter a desired ID using number keys Input ID(=10)

An item number is
3 Press key to save and exit Item registered. The weight is
displayed.

Note 1. Product ID has a range of 0 ~ 19.

4-4-2. Key Tare Input Method


Load
Step Display Screen and Key Input
Tray
Descriptions

1 Press + keys Empty


“Meaning the value of the
2 Screen display: “t = 0.000 Empty
current item number”
3 Enter a desired ID using number keys

7 Press key to save and exit

Note 1. If the remainder occurs when the input value is divided by the minimum unit, it is rounded and entered.

15
Service Manual – CI200 REV NO :

4-4-3. How to Check Subtotal, Total and Weighing Count

Key Descriptions

The current subtotal (partial summation) is displayed.

The current total (entire summation) is displayed.

The current subtotal (partial summation) is printed.


+ Subtotal is erased after it is printed.

The current total (entire summation) is printed.


+ Total is erased after it is printed.

The current weighing count is displayed.

Note 1. While printing subtotal and total, an error (Err 12) is displayed with no connection to printer, and total and weighing count are erased.
1% unit of weight can be confirmed.

16
Service Manual – CI200 REV NO :

4-5. How to Enter High Limit


Load
Step Display Screen and Key Input Descriptions
Tray

It means the current high


1 Press key.
limit.
Screen display: “H 0.000”
Enter a desired value
2 Change the high limit
using ~ keys.
The weight is displayed
3 Item
Press key to save and exit. after the high limit is saved.

Note 1. If the remainder occurs when the input value is divided into the minimum unit, the value is rounded and entered.

4-6. How to Enter Low Limit


Load
Step Display Screen and Key Input Descriptions
Tray

It means the current low


1 Press key.
limit.
Screen display: “L 0.000”
Enter a desired value
2 Change the low limit.
using ~ keys.
The weight is displayed
3 Item
Press key to save and exit. after the low limit is saved.

Note 1. If the remainder occurs when the input value is divided into the minimum unit, the value is rounded and entered.
Note 2. If the key code value of F17 and 18 was changed from the initial value, the key code should be set again.

* F1 key's basic value is set to the high limit.


* F2 key's basic value is set to the low limit.
* If the weight is greater than the high limit, the "HI" lamp appears on the screen.
If the weight is smaller than the low limit, the "LO" lamp appears on the screen.
If the weight is smaller than the low limit, the "LO" lamp appears on the screen.

17
Service Manual – CI200 REV NO :

4-7. Charge and Use Time


■ Charge the battery sufficiently when you use the product after storing it for a long time.
■ During the use of device, sign is shown (LCD) or ‘LOW BAT’ sign (LED) on the upper right corner, and then the power is turned off after a specific
time.
When the power supply of battery reaches 5.6V, the battery alert lamp is turned on. When it reaches 5.2V, the power is automatically turned off.
■ When the battery alert lamp is turned on, charge the battery.

4-8. How to Use and Charge the Chargeable Battery


■ When an adapter is connected, a red light in the power supply lamp and another red light in the charge lamp are turned on.
When the charging is completed, a green light in the charge lamp is turned on.
■ The charging takes about 12 hours.
■ The complete charge mark is turned on if an adaptor is connected with no battery.

4-9. Use Time of the Battery

조건 사용시간
CI-200A
- About 30 hours
CI-200S
C-I201A(LCD) About 26 hours

Backlight OFF About 180 hours


CI-200SC
Backlight ON About 33 hours
※ Note. The time stated above is subject to change depending on the period of battery use and
the number of batteries.
To use the battery for a longer time, adjust the automatic power switch function in F03 and the brightness of display in F25.

18
Service Manual – CI200 REV NO :
5. Set Mode

5-1. How to Enter the Set Mode

Turn on the power while pressing key at the indicator front to start the Set Mode.

Or, Hold key for about 3 seconds to move from other mode to the convesion mode.

After finishing the setup in the Set Mode, press key for a long time

5-2. Descriptions on key operations in the Set Mode

: Use them to change the setup value.

: Save changes in the setup value and move to the higher menu

: Cancel the set value and move to the higher menu

19
Service Manual – CI200 REV NO :
5-3. Set Menu Descriptions (F00 ~ F99)

General Function
F01 - Date Change
F02 - Time Change
F03 (00) Auto Power Off
F04 (10) A/D Converting Speed
F05 (10) Digital Filter
F06 (00) Vibration Filter
F07 (02) Motion Detection Condition
F08 (02) Automatic Zero Tracking Compensation
F09 (00) Weight Backup
F10 (00) Set Hold Type
F13 (10) Set Zero Range
F14 (01) ZERO, TARE Keys Availability
F16 (00) Set the Front Key Input to be Allowed
F17 (00) Set "F1" Key
F18 (00) Set "F2" Key
F21 (10) Set Initial Zero Range
F23 (09) Set Excessive Weight Check
F24 (00) Set Backlight Operational Condition (LCD)
F25 (03) Set LED Brightness or Backlight Brightness

* Note. Number in () is the default at the factory shipment.

20
Service Manual – CI200 REV NO :

RS-232 Serial Communication Function


F26 (00) Device ID
F27 (00) Parity Bit
F28 (04) Baud Rate
F29 (00) COM1 Usage
F30 (00) COM1 Ouput Format
F31 (00) COM1 - Output Mode
F32 (04) COM2 Baud Rate
F33 (01) COM2 Usage
F34 (00) COM2 Ouput Format
F35 (00) COM2 - Output Mode
Print Function
F40 (02) Set Printer in Use
F41 (00) Set Print Format
F42 (00) Automatic Print
F43 (01) Print Line Feed
F44 - User Print Message Input
F45 (01) Print Output
F47 (01) Data Initialization after Summation Print
F48 (01) Print Item Number

Checker Function
F50 (00) Measurement Mode
F51 (00) Checker Buzzer On/Off

Set Mode Initialization


F90 Password Change
F99 - Set the Set value of Set Mode to the Factory Default

* Note. Number in () is the default at the factory shipment.

21
Service Manual – CI200 REV NO :

5-4. General Function

F01
Function Date Change
Numeric key 표시부 Meaning
: assigning data Display January 10, 2002

F02
Function Time Change
Numeric key Display Meaning
: assigning data 11.30.10 11 o’clock 30 minutes and 10 seconds AM

F03
Function Auto Power OFF
Display Meaning
Setting range F03. 00 Not used.
(00 ~ 30) F03. 10 Automatic power off after 10 minutes in the waiting mode.
F03. 30 Automatic power off after 30 minutes in the waiting mode.
Note 1. The power is automatically off if the defined time continues at the zero point after the automatic power off is set.

F04
Function Setting A/D Converting Speed
Display Meaning
Setting range F04. 10 10 rounds/second
(00 ~ 99) F04. 20 20 rounds/second
F04. 80 80 rounds/second

F05
Function Setting digital filter
Display Meaning
Setting range F05. 10 Display of average for No. 10
(00 ~ 50) F05. 30 Display of average for No. 30
F05. 50 Display of average for No. 50

22
Service Manual – CI200 REV NO :

F06
Function Setting vibration filter
Display Meaning
F06. 00 Vibration filter OFF
Setting range
F06. 10 Compensation for the vibration value of 5 divisions (0.5d * 10)
(00 ~ 99)
Compensation for the vibration value of 49.5 divisions (0.5d *
F06. 99
99)
Note 1. Apply this function to a place with heavy vibrations.
(The display response speed becomes slower when the vibration filter is applied.)
Note 2. This function should be adjusted appropriately to the site while the speed of weight variations in F04 is being lowered
little by little.

F07

Function Setting Motion Detection Condition


Display Meaning
Setting range F07. 1 The 'Stable' lamp is lit if the weight changes within 0.5 division.
(1 ~ 99) F07. 2 The 'Stable' lamp is lit if the weight changes within 1 division.
F07. 10 The 'Stable' lamp is lit if the weight changes within 5 division.

F08

Function Setting Automatic Zero Tracking Compensation


Display Meaning
F08. 0 Automatic zero function is not used.
Setting range
F08. 1 If it changes slowly to 0.5 divisions or less, it is compensated.
(0 ~ 9)
F08. 2 If it changes slowly to 1.0 divisions or less, it is compensated.
F06. 9 If it changes slowly to 4.5 divisions or less, it is compensated.
Note 1. This function compensates zero automatically if the weight at the zero point does not exceed the division in a certain range within
a specific time.
Ex) If F08 is set to "4" when the maximum displayed division is 120.0kg and the value of a division is set to 0.05kg;

the display automatically shows


2.0digit "0".
(0.1Kg)

0.75 Sec
If a greater change than 100g occurs within
0.75 seconds,, the changed value is
displayed.

23
Service Manual – CI200 REV NO :

F09
Function Weight Backup Function
Display Meaning
Setting range
F09. 0 Weight backup is not used.
(0, 1)
F09. 1 Weight backup is used.
Note 1. As the backup state memorizes the initial status at zero for the weighing machine even during the blackout or when the power is turned off, the weight value is
displayed if there is any weighing object in the weighing machine when the power is turned on.
If the weighing tray is empty, press the "ZERO" key to memorize the zero again.

F10
Function Set Hold Type
Display Meaning
Ordinary hold: calculating the average of weights for shaking
F10. 0
objects
Setting range F10. 1 Peak hold: calculating the maximum value for shaking objects
(0 ~ 3) Sampling hold: calculating the sampling value for shaking
F10. 2
objects
Automatic hold: automatically calculating the average weight
F10. 3
of shaking objects
Note 1. If any load more than 'Over' is applied or at the zero, the hold is automatically released.
Note 2. Use automatic hold function, when you weight an animal or moving.

F13
Function Set Zero Range
Display Meaning
Setting range F13. 2 The 'Zero' Key is operated within 2% of the maximum weight.
(0~99) F13. 10 The 'Zero' Key is operated within 10% of the maximum weight.
F13. 99 The 'Zero' Key is operated within 99% of the maximum weight.
Note. Be aware that the load cell can be damaged if you set the value to F13=10% or more.

F14

Function ZERO and TARE Keys Availability


Display Meaning
Setting range
F14. 0 Always operated.
(0, 1)
F14. 1 Operated when the weight is 'Stable'.

24
Service Manual – CI200 REV NO :

F16
Function Set the front key input to be allowed.
Display Meaning
Setting range
F16. 0 The front keys are unlocked.
(0 ~ 1)
F16. 1 The front keys are locked.
Note 1. If it is set to 1, some function keys among the front keys cannot be used.
(Print, Hold, Tare, Step, Subtotal, Grand total, Weighing count, Item number, Setup, etc)

F17
Function Set the use of function key 1
Setting range Display Meaning
(0~15) F17. XX Set function key 1 to the key in the code table.
Note 1. Set the desired functions using <Table 1. Function Key Code>.
(LCD product = "11" and LED product = "0" as the default at the product shipment)

F18
Function Set the use of function key 2
Setting range Display Meaning
(0~15) F18. XX Set function key 2 to the key in the code table.
Note 1. Set the desired functions using <Table 1. Function Key Code>.
(LCD product = "12" and LED product = "0" as the default at the product shipment)

Table 1> Function Key Code Table


Function Name Key Code Function Name Key Code
Empty 00 Hold 08
Zero Point 01 Battery 09
Gross Weight * Net Weight 02 Item Number 10
Tare 03 High Limit (LCD, SC 11
Only)
Subtotal 04 Low Limit(LCD, SC 12
Only)
Grand Total 05 Tare Lease 13
Piece Weight Value
Weighing Count 06 15
(LCD Only)
Print 07

25
Service Manual – CI200 REV NO :

F21
Function Set the initial zero range
Display Meaning
Setting range F21. 02 Set the initial zero up to 2% of the maximum weight
(02~20) F21. 10 Set the initial zero up to 10% of the maximum weight
F21. 20 Set the initial zero up to 20% of the maximum weight
Note 1. Please consult with an engineer because setting 10 or larger value might affect the load cell greatly.
F23
Function Setting the range of check for the excessive weight (weighing unit)
Display Meaning
Setting range
F23 09 Excessive weight from the maximum weight + 9 divisions
(00~99)
F23. 99 Excessive weight from the maximum weight + 99 divisions

F24(CI-200 LCD)
Function Backlight Operation
Display Meaning
F24 0 Backlight off
F24 1 Backlight on when any key is operated.
Setting range
F24 2 Backlight on when the weight changes.
(0~5)
F24 3 Backlight on when it is 'Stable' after the weight changes.
F24 4 Backlight on when a key operates or the weight changes.
F24 5 Backlight on all the time
Note. Although it is set to 5, press the power key shortly to turn off the backlight.

F25
Function Set Backlight and LED Brightness
Display Meaning
F25 1 Set 10% of brightness
F25 2 Set 30% of brightness
Setting range F25 3 Set 50% of brightness
(1~7) F25 4 Set 60% of brightness
F25 5 Set 70% of brightness
F25 6 Set 90% of brightness
F25 7 Set 100% of brightness
Note 1. Any value out of the setting range, the brightness will be set to '3'.

5-5. RS-232 (Serial Communication) Function


F26
Function Set Device ID
Display Meaning
Setting range
F26. 00 Device ID 00
(00 ~ 99)
F26. 99 Device ID 99
Note 1. This function enables to use the unique indicator ID in the command mode.

26
Service Manual – CI200 REV NO :
F27
Function Set Parity Bit – RS232C & PRT
Display Meaning
Setting range F27. 0 Data bit 8, stop bit 1, parity bit: none
(0 ~ 2) F27. 1 Data bit 7, stop bit 1, parity bit: even number
F27. 2 Data bit 7, stop bit 1, parity bit: odd number
Note 1. F26 and F27 apply commonly to 2 serial communications (RS23C and PRT).

Serial Communication COM1 Function

F28
Function Set COM1 Baud Rate
Display Meaning
F28. 0 600 bps
F28. 1 1200 bps
F28. 2 2400 bps
Setting range F28. 3 4800 bps
(0 ~ 8) F28. 4 9600 bps
F28. 5 19200 bps
F28. 6 38400 bps
F28. 7 57600 bps
F28. 8 115200 bps

F29
Function Set COM1 - Usage
Display Meaning
Setting range
F29 0 Connect to a printer
(0 ~ 1)
F29 1 Connect to a computer or auxiliary display
* If F29: 0 and F33 : 0, "ERR-Set" is displayed with no print.

F30
Function Set COM1 - Output Format
Display Meaning
Setting range F30 0 22 bytes for CA
(0 ~ 2) F30 1 10 bytes for CA
F30 2 18 bytes for AND

F31
Function Set COM1 - Output Mode
Display Meaning
F31 0 No data out
F31 1 Transmission for both the stable and instable time (stream mode)
Setting range F31 2 One time transmission after the weight is stabilized.
(0 ~ 4) Transmission only if data is requested.
F31 3 * Data request signal: device ID (F26) _ 1 byte communication
(Data on request: 1= 0x01, 10 = 0x0A)
F31 4 Response to the data request - Command Mode
Set the value of F31 to '1' or more if the print mode is used.

27
Service Manual – CI200 REV NO :

Note 1. Command Mode Table


Data Request Signal of CI-200 CI-200
Descriptions on Request Signal
Output Signal
0 1 2 3 4 5 6 7 8 9 10 11

D dd K Z CR LF Zero Point Key Received Data Return

D dd K T CR LF Zero Point Key Received Data Return

D dd K G CR LF Gross Weight Key Received Data Return

D dd K N CR LF Net Weight Key Received Data Return

D dd H D CR LF Hold Key Received Data Return

D dd K B CR LF Print Key Received Data Return

D dd K C CR LF Total Print Key Received Data Return

D dd K W CR LF Weight Data Request Signal Received Data Return

D dd I D 0 0 0 0 0 CR LF Device Number Received Data Return

D dd H Y 0 0 0 0 0 CR LF Key Tare Value Received Data Return

D dd H I 0 0 0 0 0 CR LF High Limit(LCD Only) Received Data Return

D dd H L 0 0 0 0 0 CR LF Low Limit (LCD Only) Received Data Return

Note 1. (D : 0x44, dd:00~99, K:0x4B , Z:0x5A , CR : 0×0D, LF: 0×0A)


dd = Device Number (2byte), CR = 0×0D, LF: 0×0A
Ex) If a device number is 10, dd becomes 0x31 and 0x30.

Ex) If you want to operate the zero point key when a device number is 11, the indicator operates zeroing if the hex code of
“ 44 31 31 4B 5A 0D 0A” is sent.

Note 1. Command Mode Table


Command (ASCII Code) Description Status
HI High Limit Read / Write
LO Low Limit Read / Write
KT Key Tare Value Read / Write
CO Code Read / Write
WT Current Weight Read
ZE Operation with ZERO Key Read
TR Operation with TARE Key Read
GN Operation with Gross/Net Key Read
ID Device Number (ID) Change Read
HD Operation with HOLD Key Read
PR Operation with PRINT Key Read
TP Operation with Total Print Key Read
PW POWER OFF Read

28
Service Manual – CI200 REV NO :
Read
1 2 3 4 5
Device ID Command CR LF
Note 1. Device ID is hex value and Command is ASCII value.
[Ex] If Device ID is 13, a user wants to know the current weight value -> 0x0d
0x57 0x54 0x0d 0x0a
Write
1 2 3 4 5 6 7 8 9 10
Device ID Command DATA (Not include decimal point) CR LF

Format for Device ID Change


1 2 3 4 5 6
Device ID Command DATA CR LF

Note 2. When you change code and device number, the data value is HEX 1byte.

Serial Communication COM2 Function

F32
Function Set COM2 Baud Rate
Display Meaning
F32 0 600 bps
F32 1 1200 bps
F32 2 2400 bps
Setting range F32 3 4800 bps
(0 ~ 8) F32 4 9600 bps
F32 5 19200 bps
F32 6 38400 bps
F32 7 57600 bps
F32 8 115200 bps

F33
Function Set COM2 - Usage
Display Meaning
Setting range
(0 ~ 1) F33 0 Connect to a printer
F33 1 Connect to a computer or auxiliary display
* If F29: 0 and F33 : 0, "ERR-Set" is displayed with no print.
* COM1 and COM2 cannot be used together as the printer function.

F34
Function Set COM2 - Output Format
Display Meaning
Setting range F34 0 22 bytes for CA
(0 ~ 2) F34 1 10 bytes for CA
F34 2 18 bytes for AND

F35
Function COM2 출력방식 설정 (COM2 - Output mode)
Display Meaning
Setting range F35 0 No data out
(0 ~ 2) F35 1 Transmission for both the stable and instable time (stream mode)
F35 2 무게가 안정된 후 1 회 송신
Set the value of F35 to '1' or more if the print mode is used.

29
Service Manual – CI200 REV NO :

5-6. Print Function

F40
Function Set a printer to use
Display Meaning
Setting range F40 0 Not used.
(0 ~ 2) F40 1 DLP (Label Printer)
F40 2 DEP (Roll Printer)

F41
Function Set print format
Display Meaning
Setting range F41 0 Set print format 0
(0 ~ 2) F41 1 Set print format 1
F41 2 Set print format 2

F42
Function Set automatic print
Display Meaning
Setting range
F42 0 Manual print
(0, 1)
F42 1 Automatic print
Note 1. If the automatic print is set, print can be done with no press of print key when the weight is stable.

F43
Function Set Line Feed
Display Meaning
Setting range
F43 1 1 Line feed
(0 ~ 9)
F43 9 9 Line feed

30
Service Manual – CI200 REV NO :
【 Print Format 0 】 【Print Format 1 】
Date, Time, Weighing No. (Item No.), Net Weight Date, Time, Weighing No. (Item No.), Net Weight
2002. 1. 1 12:30 2002. 1. 1 12:30
0001 ID_01: 50.0 kg 0001 ID_01: 50.0 kg
0002 ID_01: 100.0 kg 2002. 1. 1 12:40
0003 ID_01: 200.5 kg 0002 ID_01: 50.0 kg
2002. 1. 1 12:50
0003 ID_01: 50.0 kg

【 Print Format 2 】
Date, Time, Weighing No. (Item No.), Net Weight
2002. 1. 112:30
No.0001 ID_01
Gross : 1000.0 kg
Tare : 0.0
kg
Net : 1000.0 kg

2002. 1. 112:40
No.0002
ID_01
Note 1. If the power is turned off and then on, the number and total are initialized to 0001.
Gross : 2000.0 kg
Note 2. The output of item number (ID_XX) depends on the setting in “F48”.
Tare
Note 3. The: possible number
500.0
forkg
print is a range of 1~9999.
Net : 1500.0 kg

【 Total Print Format 】


Total Format
------------------------------------
-----
ID_01 TOTAL
------------------------------------
-----
2004.06.24 14:32:54
COUNT 22
WEIGHT 4500.05kg
------------------------------------
-----
GRAND TOTAL
------------------------------------
-----
2004.06.24 14:32:58
COUNT 123
WEIGHT 12500.10kg

Note 1. When a label printer (DLP-50) is used, the subtotal and grand total functions are not
supported and Err-12 is displayed.
Note 2. After summation, data are maintained or initialized depending on the set value in F47.

31
Service Manual – CI200 REV NO :
 CAS DLP Protocol

Variable Descriptions
V00 Gross Weight (8 bytes)
V01 Tare (8 bytes)
V02 Net Weight (8 bytes)
V03 Barcode (Net Weight) (8 bytes)
V04 Count in the Count Mode (8 bytes)
V05 Percent in the Percent Mode (8 bytes)

The weight, count and percent cannot be printed at the same time.
Values that can be accurately printed are those for [weight, count and percent].

 User’s Output Message Protocol


Command (ASCII code) Descriptions Status
UM User output message Write
The maximum length is 40 bytes. 0xFF should be put in the last byte.
20 bytes are printed in a line and the message starts from the upper left corner.

F44
Function Enter the user output message
Display Meaning
Designate a character “A” equivalent to ASCII code 65 in the 12th
12 - 065
data
Set Range
(32 ~ 255) To print out the added contents, designate ASCII code 32 to 0th
00 - 032
data.
The end has to be meant by designating ASCII code 255 next to
18 - 255
the last data.

~ : set number, : coordinate increase, : end entry

(If a coordinate increase is done when the input range exceed a range of 32 ~ 255, it will be cleared with “255”)

Note 1. This function adds something to write down on the print format.
(Ex: company name, Phone number)

Note 2. Coordinates that can be designated have a range from 0 to 71, of which 0th data designates whether or not to print the added
contents (032: printed, others: not printed). Accordingly, the actually printed contents will include contents from 1st data to the part
right before the coordinate where data 255 is assigned.

Note 3. If you want to add the company name “CAS” to the existing print format, you might assign as follows;
P00-032 (ASCII code 32: data starts),
P01-067 (ASCII code 67: character C)
P02-065 (ASCII code 65: character A)
P03-083 (ASCII code 83: character S)
P04-255 (ASCII code 255: data ends)

32
Service Manual – CI200 REV NO :
F45
Function Set print output
Display Meaning
Setting range
(0, 1) F45 0 Print on both the stable and instable time
F45 1 Print when the weight is stable.

F47
Function Initialize data after the summation is printed.
Display Meaning
Setting range
F45 0 Maintain the status
(0, 1)
F45 1 Initialize data after the summation is printed.

F48
Function Setting print item number
Display Meaning
설정범위
F45 0 Not printing item number on print output
(0, 1)
F45 1 Printing item number on print output

5-7. Checker Function

F50
Function Select the weighing mode (LCD, SC Only)
Display Meaning
Setting range F50 0 Not used.
(0 ~ 2) F50 1 Use as the checker mode
F50 2 Use as the limit mode

[ CHECKER MODE ]
Weight
(Low Limit) (High Limit) OUT
Comm PUT
0 kg 50 kg 100 kg
Signal
1
LOW
0
1
HIGH
0
1
OK
0
Note 1. All the outputs are generated regardless of the stable status.

[LIMIT MODE ]
Weight
(Low Limit) (High Limit) OUT
Comm PUT
0 kg 50 kg 100 kg
Signal
1
LOW
0
1
HIGH
0
1
OK
0

Note 1. OK signal is displayed only for the stable status.

33
Service Manual – CI200 REV NO :

F51
Function Set Buzzer On/Off on the Checker Function (LCD, SC Only)
Display Meaning
Setting range
F51 0 General functions are operated as the buzzer.
(0, 1)
F51 1 Buzzer ON when the checker function is OK.

5-8. Other Functions


F90
Function Password Change
Display Meaning
Setting range
F98. 0 Password not changed.
(0, 1)
F98. 1 Password Changed
____
Enter the current password using numeric keys.
Good
Password ____
Enter a new password.
Change PASS
____
Enter the new password again.
Change

F99
Function Set default
Display Meaning
Setting range
0 No initialization functions for indicator.
(0, 1)
1 Carry out the initialization functions for indicator.
Note 1. To set values to the same as the factory default for the indicator, press the setup key after setting F99 to 1.

34
Service Manual – CI200 REV NO :
6. Test Mode
6-1. How to Enter the Test Mode

Test mode starts when the power is turned on while pressing key in the front of the indicator.
Press the number for the test menu as you wish.

To enter the weighing mode during test, press key for a long time.

6-2. Test Menu (TEST 1 - TEST10)

Test 1: Key test


Test 2: Display test
Test 3: Load cell test and A/D conversion test
Test 4: RS-232 serial communication test (COM1, COM2)
Test 5: Printer test
Test 8: EEPROM test
Test 9: Battery test
Test 10: Clock (RTC) test

TEST 1

Function: Key test


Used key Display Descriptions
When you press any key to test, the
: : Higher Menu 1 1 number and code for the key are displayed
Other keys: Test on the screen.

<Key List>
Key Number Code Key Number Code Key Number Code

1 1 6 6 0 12

2 0 7 9 70 99

3 2 8 8 28 28

4 5 9 10 29 29

5 4 11 13

35
Service Manual – CI200 REV NO :
TEST 2

Function: Display Screen Test

Used key Display Descriptions

: Higher
Menu An LCD lamp is on.
Other keys
:Test
An LED lamp is on.

TEST 3

Function: Load cell test and A/D conversion test


Used key Display Descriptions
The internal value for the current
:Higher XXXXXX weight value is displayed.
Menu X.XX The output value of the current
load cell is displayed in mv/V.

Note 1. If key is pressed, the internal value of the current weight and the output of load
cell (mv/V) are displayed repeatedly.
Note 2. Check this number to see if it moves well, while loading or unloading a weight to the
load tray. If the number is fixed or “0” is displayed, check the connection of load cell
once again.

TEST 4

Function: Serial Communication Test


Used key Display Descriptions

: Higher Menu Tx -- Rx Status to wait for transmission or


Other keys: ------ reception
Test 05 --13 Transmission: 5, Reception: 13

Note 1. Run this test while the communication program in the computer (ex: Hyper Terminal)
is executing after connecting a serial port in the computer to the serial port on the back.
Note 2. Send ‘1’ from the computer keyboard, check whether or not ‘1’ is received properly
on the indicator’s screen, and then check whether or not ‘1’ is received properly on the
computer after pressing ‘1’ from the indicator’s keyboard.

TEST 5

Function: Printer Test


Used key Display Descriptions

: Higher Menu No abnormality in the printer.


Other keys: Print Check the connection of the printer
Test connector..

Note 1. Designate a printer used in the Set Mode (F30) in advance.


Note 2. If the printer connection and the designation are done correctly, the following details
will be shown in the printer.

36
Service Manual – CI200 REV NO :

CAS Corporation
Come And Succeed
TEL 1577-5578
TEST OK

TEST 8(Except LCD)

Function: EEPROM Test


Used key Display Descriptions

: Higher Menu ROM OK Displaying the status of EEPROM operation

TEST 9

Function: Battery test


Used key Display Descriptions

Displaying the current voltage of battery


: Higher Menu b 6.15 (6.15V)

TEST 10

Function: RTC Test


Used key Display Descriptions

XX : Displaying the progress of seconds


: Higher Menu SEC XX (SEC)

Note 1. If key is pressed, the current second changes to '0'.

37
Service Manual – CI200 REV NO :

7. Weight Setup (Calibration) Mode


What is the weight setup?
It refers to the calibration to set the displayed value to the actual weight in displaying weights.

How to Access to the Weight Setup Mode


Turn on the power supply to access to the weight setup mode while pressing Cal S/W after
removing the sealing. Press the setup key long in the weight setup mode to return to the
weighing mode.

7-1. Weight Setup Menu (CAL1 – CAL9)


CAL 1: Maximum capacity
CAL 2: Minimum division and decimal position setting
CAL 3: Weight calibration
3-1. Setting the range of multiple calibration
3-2. Zero calibration
3-3. Setting weight
3-4. Span calibration
CAL 7: Gravity adjustment
CAL 8: Zero adjustment
CAL 9: Factor calibration
CAL 10: Setting dual range

CAL 1 (CAL 1 automatically starts.)

Function: Setting Maximum Value


Range of set value: 1 ~ 99,999
Used key Display Descriptions
:Save and next
Menu navigation C= 10000 Max. value = 10000kg
~
: Set value change
:End
C= 10 Max. value = 10kg

Note 1. It means the maximum weight value to be weighed by the scale.

CAL 2

Function: Minimum division and decimal position setting


Range of set value: 0.001 ~ 9999
Used key Display Descriptions
:Save and next d= 0.001 Minimum division 0.001 kg
Menu navigation
~ d= 0.01 Minimum division 0.01 kg
: Set value change d= 0.1 Minimum division 0.1 kg
d= 1 Minimum division 1 kg
: Set decimal point
and end d= 10 Minimum division 10 kg

38
Service Manual – CI200 REV NO :

Note 1. To end CAL2, press key when a decimal point is set.


Note 2. The minimum division means the value of a division.
Note 3. Set the external resolution within 1/30,000 as the value by dividing the maximum weight by the minimum division.
If the external resolution is 1/30,000 or more, Err 21 is shown.
Note 4. The position of a decimal point is decided by the position of a decimal point for the minimum division set in CAL2.
Note 5. If the minimum division is set to any value out of 1, 2 and 5 unit, "ERR DIV" is shown.

CAL 3
CAL 3-1
Function: Setting Multi Calibration Step
Range of set value: 1 ~ 5
Used key Display Descriptions
Setting multi calibration for step 1
:Save and next STEP- 1 (CAL3-3 and CAL 3-4 are carried out once)
Menu navigate
Setting multi calibration for step 3
STEP- 3 (CAL3-3 and CAL 3-4 are carried out three
~ times.)
: Set value change
Setting multi calibration for step 5
: STEP- 5 (CAL3-3 and CAL 3-4 are carried out five
End times.)

* If the actual curve of load cell is a straight line, set the range of weight setup to 1.

* A function to use, when the output of load cell is corrected by setting multiple points in some sections because the actual curve of load
cell is not a straight line.

39
Service Manual – CI200 REV NO :

CAL 3-2
Function: Zero Calibration
Used key Display Descriptions

:Zeroing
UnLoAd Empty the load tray and press the setup key.
The current weight value is displayed.
1234 Confirm 'Stable' and press the setup key.
:End
--- Zeroing in progress...

Note 1. If zeroing finished with no error, it moves to Setting Weight (CAL 3-3) although no key is pressed.
Note 2. When zero point is too low, an error message "ERR27" is displayed.
Note 3. When zero point is too high, an error message "ERR26" is displayed.

CAL 3-3
Function: Setting Weight
Range of set value: 1 ~ 99,999
Used key Display Descriptions
It means the weight setting mode.
:Save and next LOAD 1 (Number = multi calibration number)
Menu navigation
~ : Set value W=100.00 100.00 (unit: Kg or Ton)
change
:End W= 0.10 0.10 (unit: Kg or Ton)

Note 1. Set the weight within a range of 10% ~ 100%.


Although 100% of the maximum weight is given as the initial value, enter the desired weight again if the
weight is different from the initial value.
(If the weight exceeds the maximum weight, "ERR 23" is displayed.)
If the weight is 10% or less, "Err 20" is displayed and if the calibration is set to 10% or less, the accuracy
is lowered.

CAL 3-4
Function: Weight Calibration)
Used key Display Descriptions
Load the weight set in CAL 4-3 and press the
:Span adjustment
LoAd setup key.
The current weight value is displayed.
12345 Confirm 'Stable' and press the setup key.
:End --- Span adjustment in progress...

Note 1. CAL 3-3 and CAL 3-4 are repeated as many as STEP is set in CAL 3-1.
At this time, the weight value should be set to a value greater than the previous one.
Note 2. Move to CAL-1 if the span adjustment is over with no error.
Note 3. When zero point is low, an error message "ERR24" is displayed.
Note 4. When zero point is high, an error message "ERR25" is displayed.
Note 5. After finishing calibration, press the setup key for 2 seconds or more to convert to the weighing mode.

40
Service Manual – CI200 REV NO :

CAL 7
Function: Gravity Adjustment
Used key Display Descriptions
It means you accessed to the menu for the
:Save and next G-CAL gravity adjustment.
Menu navigation
Gr-CAL
~ : Set value Set the gravity for the production place.
9.XXXX
change
Gr-SET Set the gravity for the place to use the
:End product.
9.XXXX

Note 1. If the gravity of the indicator production place is different from that of the place to use, the gravity adjustment can be done using
this function.

CAL 8
Function: Zero adjustment - calibration when any zeroing error occurs.
Used key Display Descriptions

2-CAL Empty the load tray and press the setup key.
:Zeroing
The current weight value is displayed.
1234 Confirm 'Stable' and press the setup key.
:End --- Zero adjustment in progress...

Note 1. Use this function when zeroing is not passed for any shock to the load cell.
The range of zero adjustment is 0 ~ 2mV/V.
Note 2. Move to CAL-1 if the zero adjustment is over with no error.
Note 3. When zero point is too low, an error message "Err27" is displayed.
Note 4. When zero point is too high, an error message "Err 26" is displayed.

CAL 9
Function: Factor Calibration
Used key Display Descriptions
This function cannot be used because of multi
:Save and next NOT USE calibration.
Menu navigation
~ : Set value FACtor It means you entered the factor correction mode.
change
:End 12345 The current factor is displayed.

Note 1. As this is a menu to set the weight setup with no weight, general users have no need to use it.
Note 2. This can be used only when the range of multi calibration in CAL 4-1 is set to 1.
"NOT USE" is displayed when the range of CAL 4-1 is set to 2 or larger.
Note 3. Enter a password to enter the factor correction mode.

41
Service Manual – CI200 REV NO :

CAL 10

CAL 10-1
Function: Setting Dual Range
Range of set value: 0 ~ 1
Used key Display Descriptions
:Save and next
Menu navigation DUAL- 0 Dual range function is not used.
~ : Set value
change
DUAL- 1 Dual range function is used.
:End
Note 1. If the resolution capability is 1/10,000 or higher, "OVER" message is displayed and return to the CAL menu mode.

CAL 10-2
Function: Setting the applied section for the Dual Range
Range of set value: 0 ~ 99999
Used key Display Descriptions
:Save and next M 1000 Set the dual range under 1000kg
Menu navigation
~ : Set value M 5000 Set the dual range under 5000kg
change
:End M 10000 Set the dual range under 10000kg

Note 1. If the input value is greater than the maximum value, "ERR SET" message is displayed and
returned to the CAL menu mode.

42
Service Manual – CI200 REV NO :

7-2. How to Seal the Indicator (Sealing)

After the calibration mode is carried out, proceed to the following step.
1. Tighten the CAL switch bolt.
2. Connect the sealing wire as shown in the picture.
3. Press the sealing wax as shown in the picture.

Sealing Point

43
Service Manual – CI200 REV NO :

8. Servicing & Parts Replacement


8-1. Error Message from the Weight Setup Mode

Error Cause Solution


Lower the resolution.

The resolution was set in excess As the resolution = maximum tolerance / value of one division, adjust the
Err 20 of the tolerance 1/10,000. resolution to 1/10,000 or less by correcting either the maximum allowable
weight in CAL 1 or the value of one division in CAL3 in the weight setup
mode.
Lower the resolution.
The resolution was set in As the resolution = maximum tolerance / value of one division,
Err 21 excess of the tolerance adjust the resolution to 1/30,000 or less by correcting either the
1/30,000. maximum allowable weight in CAL 1 or the value of one division in
CAL3 in the weight setup mode.
The weight for the span
adjustment was set to less Set the weight to 10% or more of the maximum capacity (set in CAL
Err 22 than 10% of the maximum 1) from CAL 4 in the weight setup mode.
capacity.
The weight for the span
adjustment was set to more Set the weight within the maximum capacity (set in CAL 1) from
Err 23 than 100% of the maximum CAL 4 in the weight setup mode.
capacity.
Set the weight again by lowering the resolution as the setting of the
current resolution is not possible because of either abnormality or
Err 24 Too low span. lower output in the load cell.
Two low weight for PCS and percent sample.
There is either any abnormality or too high output in the load cell.
Execute steps from the zeroing step in CAL 4 in the weight set up
Err 25 Too high span. again.
Two high weight for PCS and percent sample.

Check whether or not the load tray is empty.


Err 26 Too high zero point.
Retry the weight setup after check at the test mode 3.

Set the weight setting again after confirming what force is given to
Err 27 Too low zero point. the load tray of the scale in the test mode 3.

Err 28 Weight is shaking. Check the connection of the load cell connector.

44
Service Manual – CI200 REV NO :

9. Options Installing
SERIAL INTERFACE

45
Service Manual – CI200 REV NO :

10. Update

46
Service Manual – CI200 REV NO :

11. Exploded Views & Parts List

47
Service Manual – CI200 REV NO :

48
Service Manual – CI200 REV NO :

49
Service Manual – CI200 REV NO :

50
Service Manual – CI200 REV NO :

※ CI200 SERIES INDICATOR (ABS TYPE)

※ BODY ASS'Y

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

1 2000-A00-0316 0 FRONT COVER CI200 206*139*40.05 ABS 1

2 2000-A00-0317 0 REAR COVER CI200 206*139*64.5 ABS 1

3 2000-A00-0318 0 BATTERY COVER CI200 158.5*70.8*17.8 ABS 1

DISPLAY COVER
4 2050-A00-6335 0 CI200 182.6*59.1*1T PC 1
TOOL(LCD)

DISPLAY COVER
4 2050-A00-6337 0 CI200 182.6*59.1*1T PC 1
TOOL(LED)

5 2050-A00-6336 0 NAME TAG CI200 179.6*5.6*1T PC 1

6 2050-A00-6343 0 RS-232 STICKER CI200 35.2*14*0.8T PC 1

DB-2(영공) 3 등급,
7 1810-DB2-0033 5 SPEC PLATE - 1
ENGLISH

8 1563-A00-0308 0 RIVET Ø3.2*8 - 2

9 1265-A00-0030 0 BOLT-SEALING M6*23(NT-200, 201A) - 1

10 1265-A00-0031 A BOLT-SEALING M3*26(NT-200,201A) - 1

BOLT-BATTERY M4*0.7*8.5(SUS303)TP-
11 1261-A00-0004 0 SUS 1
COVER 1,2

12 1561-MSU-0300 0 E-RING Ø3*Ø7*0.6-SUS SUS 1

51
Service Manual – CI200 REV NO :
SCREW-
13 1510-A00-0306 0 M3*6 - 4
TAPPING(PH)-1

14 1510-A00-0412 0 SCREW M4*12L - 2

Metallic hexagona
15 7720-GND-0020 0 TE-501(CI) - 1
ground terminal

※ BODY ASS'Y _ Delate Electronic Part Wireless Option choosen

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

16 2620-A00-0034 0 ANTENNA CAP CI200 17.5*15.7*18.8 RUBBER 1

※ BODY ASS'Y _ Delate Battery Option Choosen.

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

17 7520-P00-0633 0 BATTERY-PB 6V3.3AH(DBII BASIC) - 1

CUSHION
18 2631-A00-0023 0 40*26*2T(MWII,DBB,ER) - 1
-BATTERY COVER

※ RUBBER KEY

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

KEY COVER _
19 2000-A00-0320 0 CI200 180.3*43.6*13.7 ABS 1
RUBBER

20 2620-A00-0035 0 RUBBER KEY CI200 176.5*39.8*14.7 RUBBER 1

RUBBER KEY
21 2010-A00-0036 0 CI200 177.5*40.8*0.2T PC 1
SHEET

※ C/T BOX ASS'Y

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

22 9100-AB1-0001 0 C/T BOX CI200 (380*300*169) - 1

52
Service Manual – CI200 REV NO :
STYROFOAM
23 9204-AS0-0021 0 CI200 (380*300*50) - 1
BOX (UP)

STYROFOAM
24 9204-AS0-0022 0 CI200 (380*300*125) - 1
BOX (LOW)

25 9303-A00-0004 A POLY BAG 350*450*0.05T(HEAD) - 1

MANUAL
26 9301-A00-0003 0 POLY BAG - 1
(170*250*0.05T)

27 9400-A00-0046 0 SILICAGEL 10g - 2

28 9900-A00-0001 0 SEALING LEAD - - 1

29 9900-A00-0002 0 SEALING WIRE 300M/ROLL - 0.002

※ CRADLE OPTION

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

30 2000-A00-0321 0 CRADLE CI200 229.1*81.5*130 ABS 1

31 2600-A00-0099 0 CRADLE FOOT CI200 Ø14.6*Ø5*1.3T NBR 4

32 2009-A00-0006 0 STOP BOLT Ø38*17(NT-200,201A) - 2

33 9302-A00-0005 B POLY BAG 270*350*0.05T - 1

※ BATTERY OPTION

No. IMAGE CODE REV. PART NAME SPEC MATERIAL Q'TY

BATTERY
34 2013-A00-0009 0 HDPE 111.7*47.5*16.7 HDPE 1
HOLDER

BATTERY SPRING
35 1590-A00-0032 0 Ø9*0.6*3(MW-II) - 1
A

BATTERY SPRING
36 1590-A00-0033 0 Ø9*0.6*6*3(MW-II) - 1
B

53
Service Manual – CI200 REV NO :
BATTERY SPRING
37 1590-A00-0034 0 Ø9*0.6*3*6(MW-II) - 1
C

BATTERY SPRING
38 1590-A00-0035 A Ø9*0.6*8(MW-II) - 1
D

39 9505-A00-0041 0 벨크로 데이프 CI200 15*160*1.5T - 2

54
Service Manual – CI200 REV NO :

CI-200[LED] Main PCB ASS'Y


No Part Code Parts Name DESCRIPTION PART TYPE Unit Q'ty Remark

1 61A0A000001A SDI Module SDI Module DIP(1.27Pitch) EA 1 SDI Module

2 6100PCI02000 PCB-Main MAIN PCB 2Layers EA 1 PCB MAIN

3 6236IS062780 IC(LED DRIVER) TD62783AF EA 1 U4

4 6236IS00573A IC(LATCH) 74HC573D EA 2 U2,U3

5 6236IS020030 IC(TR ARRARY) ULN2003AD EA 1 U1

6 6232IS032320 IC(INTERFACE) SP3232ECY(3.3V) TSSOP16 EA 1 U5

IC(DC DC
7 6242I003406A MC34063AD SOIC-8 EA 1 U8
CONVERTER)

8 6220IS0C5020 IC(REGULATOR) XC6204C502MR SOT-25 EA 2 U9,U11

9 6220IS0C3320 IC(REGULATOR) XC6204C332MR SOT-25 EA 1 U7

10 6241IS003930 IC(OP AMP) LM393D(SOP) SOIC-8 EA 1 U10

11 6220IS078090 IC(REGULATOR) LM7809 D-PAK EA 1 U6

12 6281I0022220 TRANSISTOR-CHIP 2N2222 SOT-23 EA 5 Q1,Q2,Q3,Q4,Q5

13 6294ICP01840 DIODE-CHIP KDS184 SOT-23 EA 2 D10

14 6291IS058190 DIODE-CHIP 1N5819 SMD EA 4 D11,D12,D13,D15,

15 6291IP054060 DIODE 1N5406 DIP EA 1 D14

16 6712CHP02700 CONDENSER-CHIP CL21F 270KBNC 2012 EA 4 C5,C12,C14,C16

17 6712CHP04710 CONDENSER-CHIP CL21F 471KBNC 2012 EA 1 C27

18 6712CHP01020 CONDENSER-CHIP CL21F 102KBNC 2012 EA 4 C7,C8,C9,C10

C1,C2,C3,C6,C13,

19 6712CHP01040 CONDENSER-CHIP CL21F 104KBNC 2012 EA 13 C15,C17,C25,C26,

C28,C29,C30,C31

C4,C11,C18,C19,
20 6712CHP01050 CONDENSER-CHIP CL21F 105KBNC 2012 EA 7
C22,C23,C24

21 6710CAP0103B CONDENSER-CERAMIC 0.01uF/3KV EA 3 CV1,2,3

CE1,CE2,CE5,CE6,
22 6706C1601000 CONDENSER-ELEC-CAP 100uF/16V ø6.3 SMD EA 5
CE7

23 6706C2504700 CONDENSER-ELEC-CAP 470uF/25V ø10 SMD EA 2 CE3,CE4

24 6512CJ000033 RESISTOR 2W CFR 0.33Ω (±5%) DIP EA 1 R35

25 6527ID00000B RESISTOR-CHIP 0Ω RESISTOR SMD EA 10 R1,2,4,7,10,13,

55
Service Manual – CI200 REV NO :
1/10W (2012) 15,16,17,18

RESISTOR-CHIP R3,5,6,8,9,11,
26 6527ID004700 RR1220P-470D(47Ω) 2012 EA 9
1/10W 12,14,41

RESISTOR-CHIP RR1220P-
26 6527ID030000 2012 EA 1 R55
1/10W 301D(300Ω)

RESISTOR-CHIP RR1220P-331D
27 6527ID003300 2012 EA 1 R27
1/10W (330Ω)

RESISTOR-CHIP
28 6527ID300100 RR1220P-102D(1KΩ) 2012 EA 2 R29,R49
1/10W

RESISTOR-CHIP
29 6527ID300200 RR1220P-202D(2KΩ) 2012 EA 3 R40,47,54
1/10W

RESISTOR-CHIP RR1220P-
30 6527ID300470 2012 EA 1 R28
1/10W 472D(4.7KΩ)

RESISTOR-CHIP RR1220P- R19,R21,R26,R30,


31 6527ID301000 2012 EA 7
1/10W 103D(10KΩ) R39,R51,R34

RESISTOR-CHIP RR1220P- R37,38,44,45,50,


32 6527ID302000 2012 EA 6
1/10W 203D(20KΩ) 52

RESISTOR-CHIP RR1220P-
33 6527ID303300 2012 EA 1 R46
1/10W 333D(33KΩ)

RESISTOR-CHIP RR1220P-
34 6527ID304700 2012 EA 2 R32,33
1/10W 333D(47KΩ)

RESISTOR-CHIP RR1220P-
34 6527ID310000 2012 EA 3 R36,R48,R53
1/10W 104D(100KΩ)

RESISTOR-CHIP RR1220P-
35 6527ID349900 2012 EA 1 R43
1/10W 4993D(499KΩ)

RESISTOR-CHIP RR1220P-
36 6527ID368000 2012 EA 1 R42
1/10W 684D(680KΩ)

L1,2,3,4,5,6,7,

37 6670T0001020 INDUCTOR-CHIP MMZ Y102C 2012 EA 15 8,9,10,11,12,14,

17,18

38 6670T0102200 INDUCTANCE 220uH(NT SERIES) DIP EA 1 L13

39 6800F0002200 EMI FILTER EFST221YTB(220pF) DIP-3 EA 8 F1,2,3,4,5,6,7,8

40 6800F0035650 EMI BEAD FILTER BFS-3565AOB DIP EA 1 BD1

41 6804F0010040 LINE FILTER T1004(HM3A) DIP EA 1 L15

42 7230D00C0270 LED SND1020 UOR DIP-18 EA 3 LED1,2,3

ø5-(R,G) BL-BVT
43 7232DRG00040 LED LAMP DIP EA 1 LED4
204(ANODE)

44 7232DR00005A LED LAMP ø5-LED DIP EA 9 D1,2,3,4,5,6,7,8,9

56
Service Manual – CI200 REV NO :
45 7813C000040A PIN HEADER A2-40PA-2.54DS EA 1 CON5,SW18

LWL0640-03
46 7802CLL00030 CONNECTOR(WAFER) EA 1 CN2(ADAPTOR)
(LSW250-03)

5273-03 (LPH03-
47 7804CCN73030 CONNECTOR(WAFER) EA 1 CN3(BAT)
03)

48 7805CCN67030 CONNECTOR(WAFER) 03-5267 EA 2 CON4,CON6

49 7801CLW0007A CONNECTOR(WAFER) LW0640-07 (GOLD) EA 1 LC1(LOADCELL)

50 7807CFP00100 FPC-CONNECTOR FCZ254-10R EA 1 CON3

51 7600STA19020 TACK S/W 11902(DJTA-1102) EA 1 SW15

52 7600SLD00020 SLIDE S/W INCA-2(DJMM-12V) EA 1 SW16

1.6A/250V ø5
53 7620S0516000 FUSE EA 1 FUSE
UL,S,VDE,BSI(유)

54 7630S0002050 FUSE HOLDER GF-205B(EXP-300L) EA 1 FUSE

55 7520P0002000 BATTERY-LIMN CR1220-PIN TYPE EA 1 BT1

14A4012P(EFM-
56 7002Z0001200 PIEZO BUZZER BZ-14-CS EA 1 BUZ1
250A)

57 7562P1202CE0 Adaptor 12V/1.25A EA 1

57
Service Manual – CI200 REV NO :

CI201[LCD] Main PCB ASS'Y


No Part Code Parts Name DESCRIPTION PART TYPE Unit Q'ty Remark

1 61A0A000001A PCB-SDI MODULE 61A0-A00-0001-0 DIP(1.27Pitch) EA 1 SDI Module

2 6100PCI02010 PCB-Main PCB MAIN(CI201) 2Layers EA 1 PCB MAIN

3 6224I0016210 IC(LCD Driver) HT1621 TSSOP48 EA 1 U1

4 6232IS032320 IC(INTERFACE) SP3232ECY(3.3V) TSSOP16 EA 1 U2

IC(DC DC
5 6242I003406A MC34063AD SOIC-8 EA 1 U3
CONVERTER)

6 6220IS0C5020 IC(REGULATOR) XC6204C502MR SOT-25 EA 2 U4,U5

7 6220IS0C3320 IC(REGULATOR) XC6204C332MR SOT-25 EA 1 U6

8 6241IS003930 IC(LINEAR) LM393D(SOP) SOIC-8 EA 1 U7

9 6220IS078090 IC(REGULATOR) LM7809 D-PAK EA 1 U8

10 6281I0022220 TRANSISTOR-CHIP 2N2222 SOT-23 EA 5 Q1,2,3,4,6

11 6281I0016660 TRANSISTOR-CHIP KTA1666 SOT-89 EA 1 Q5

12 6294ICP01840 DIODE-CHIP KDS184 SOT-23 EA 2 D1,2

13 6291IS058190 DIODE-CHIP 1N5819 SMD EA 4 D4,5,6,7

14 6291IPO54060 DIODE 1N5406 DIP EA 1 D3

15 6712CHP02700 CONDENSER-CHIP CL21F 270KBNC 2012 EA 4 C7,10,12,14

16 6712CHP04710 CONDENSER-CHIP CL21F 471KBNC 2012 EA 1 C23

17 6712CHP01020 CONDENSER-CHIP CL21F 102KBNC 2012 EA 4 C1,2,3,4

C5,8,11,13,15,20,

18 6712CHP01040 CONDENSER-CHIP CL21F 104KBNC 2012 EA 15 21,22,24,25,26,

CB1,CB2,CB3,CB4

19 6712CHP01050 CONDENSER-CHIP CL21F 105KBNC 2012 EA 6 C6,9,16,17,18,19

CONDENSER-ELEC-
20 6706C1601000 100uF/16V ø6.3 SMD EA 6 CE3,4,5,6,7,8
CAP

CONDENSER-ELEC-
21 6706C2504700 470uF/25V ø10 SMD EA 2 CE1,2
CAP

CONDENSER-
22 6710CAP0103B 0.01uF/3KV EA 3 CV1,2,3
CERAMIC

23 6512CJ000033 RESISTOR 2W CFR 0.33Ω (±5%) EA 1 R14

RESISTOR-CHIP
24 6527ID004700 RR1220P-470D(47Ω) 2012 EA 1 R16
1/10W

58
Service Manual – CI200 REV NO :
RESISTOR-CHIP
25 6527ID010000 RR1220P-101D(100Ω) 2012 EA 4 R7,8,9,10
1/10W

RESISTOR-CHIP
26 6527ID030000 RR1220P-301D(300Ω) 2012 EA 1 R35
1/10W

RESISTOR-CHIP
27 6527ID300100 RR1220P-102D(1KΩ) 2012 EA 1 R26
1/10W

RESISTOR-CHIP
28 6527ID300200 RR1220P-202D(2KΩ) 2012 EA 3 R15,30,31
1/10W

RESISTOR-CHIP RR1220P-
29 6527ID300220 2012 EA 1 R11
1/10W 222D(2.2KΩ)

RESISTOR-CHIP RR1220P-
30 6527ID300470 2012 EA 1 R12
1/10W 472D(4.7KΩ)

RESISTOR-CHIP RR1220P-
31 6527ID300820 2012 EA 1 R2
1/10W 822D(8.2KΩ)

RESISTOR-CHIP R1,3,4,13,17,22,
32 6527ID301000 RR1220P-103D(10KΩ) 2012 EA 10
1/10W 27,42,44,34

RESISTOR-CHIP
33 6527ID303300 RR1220P-333D(33KΩ) 2012 EA 5 R5,6,20,21,25
1/10W

RESISTOR-CHIP
34 6527ID304700 RR1220P-333D(47KΩ) 2012 EA 2 R32,33
1/10W

RESISTOR-CHIP RR1220P- R23,24,28,29,43,


35 6527ID310000 2012 EA 6
1/10W 104D(100KΩ) 45

RESISTOR-CHIP RR1220P-
36 6527ID349930 2012 EA 1 R19
1/10W 4993D(499KΩ)

RESISTOR-CHIP RR1220P-
37 6527ID368000 2012 EA 1 R18
1/10W 684D(680KΩ)

L1~12,14,16 BD1,
38 6670T0001020 INDUCTOR-CHIP MMZ Y102C 2012 EA 16
BD2

39 6670T0102200 INDUCTANCE 220uH(NT SERIES) DIP EA 1 L13

40 6800F0002200 EMI FILTER EFST221YTB(220pF) DIP-3 EA 8 F1~8

41 6800F0035650 EMI BEAD FILTER BFS-3565AOB DIP EA 1 BD5

6804F00-
42 LINE FILTER T1004(HM3A) DIP EA 1 L15
1004-0

ED,DBII-LCD
43 7224D0000030 BACK LIGHT EA 1 BL
(one module) ㄷ

2402TF-P,B1

44 7212D000010A LCD (DB- EA 1 LCD

II,DBB,NT)YEEBO

59
Service Manual – CI200 REV NO :
ø5-(R,G)
45 7232DRG00040 LED LAMP EA 1 LED
BL-BVT 204(ANODE)

46 7813C000040A PIN HEADER A2-40PA-2.54DS EA 1 JP2,SW1,OP1

47 7804CCN73030 CONNECTOR(WAFER) 5273-03 (LPH03-03) EA 1 CN2(BAT)

LWL0640-03
48 7802CLL00030 CONNECTOR(WAFER) EA 1 CN1(ADAPTOR)
(LSW250-03)

49 7805CCN67030 CONNECTOR(WAFER) 03-5267 EA 2 CN4,6

50 7801CLW0007A CONNECTOR(WAFER) LW0640-07 (GOLD) EA 1 CN3(LOADCELL)

51 7600STA19020 TACK S/W 11902(DJTA-1102) EA 1 CAL_KEY1

52 7807CFP00100 FPC-CONNECTOR FCZ254-10R EA 1 CN5

1.6A/250V ø5
53 7620S0516000 FUSE EA 1 FUSE
UL,S,VDE,BSI(유)

54 7630S0002050 FUSE HOLDER GF-205B(EXP-300L) EA 1 FUSE

55 7520P0002000 BATTERY-LIMN CR1220-PIN TYPE EA 1 BT1

56 7002Z0001200 PIEZO BUZZER 14A4012P(EFM-250A) BZ-14-CS EA 1 BZ1

12.Revision
NO CAUSE DATE APPROVAL

60
Service Manual – CI200 REV NO :

13.Schemetic
1. CI20OA(LED)
1-1 main

AVCC5V
LC1 KEY 0 SW1 SW2 SW3 SW4
1 1 2 EX+ L4 102
2 1 2 EX- EX+ NUM1 NUM2 NUM3 NUM4 CON1 CON2
3 1 2 SEN+
AVCC5V 1 2 AVCC5V RTC_POWER 33 34 RTC_POWER
4 1 2 SEN- L8 102 CE8 PA0 PA1
3 4 WK_UP 35 36 BAT_CHK
5 1 2 LC_SIG+ EX- 100u/16V KEY 1 SW5 SW6 SW7 SW8 PB3 PB0
SIG+ 5 6 SIG+ JTDO 37 38 POWER_CHK
6 1 2 LC_SIG- PB4 PB1
SIG- 7 8 SIG- JNTRST 39 40 BUZZER
7 1 2 NUM5 NUM6 NUM7 NUM8
L3 PB5 PA2
AD_REF+ 9 10 AD_REF- LOW_BAT 41 42 TXD2
T.B L1 SW11 SW12 PC12 PA3
KEY 2 11 12 POWER_CON 43 44 RXD2
SIP-7P-U L2 R17 SW9 SW10 F1 CLR
L6 0 13 14 45 46
VDD3.3V 15 16 VDD3.3V VDD3.3V 47 48 VDD3.3V
L5 EX+ SEN+ NUM9 NUM0
L7 D0 PB8 PA11 PC8 PC7
17 18 LC_PW_CECOM_CON 49 50 K_SCAN3
L16 R18 D1 PB9 PA12 PC9 PC6
19 20 DISPLAY _PW_CE
DIGIT_CON 51 52 K_SCAN2
STP3 STP 0 KEY 3 SW13 SW14 D2 PB10 PA13 PC10 PC5
D3 PB11 21 22 JTMS CAL 53 54 K_SCAN1
EX- SEN- PA14 PC11 PC4
23 24 JTCK EXT1 55 56 K_SCAN0
F2 SET
STP4 STP D4 PB12 PA15 PC13 PC3
25 26 JTDI TAMPER 57 58 KEY 3
F1 R19 K_SCAN0 1 2 L9 D5 PB13 PA8 PC2
27 28 BOOT0 485_CON 59 60 KEY 2
221 1K_1% K_SCAN1 1 2 L10 D6 PB14 PB6 PA9 PC1
29 30 I2C_SCL TXD1 61 62 KEY 1
STP5 STP SEN+ 1 3 AD_REF+ K_SCAN2 1 2 L11 D7 PB15 PB7 PA10 PC0
K_SCAN3 31 32 I2C_SDA RXD1 63 64 KEY 0
1 2 L12 D[7:0]
2

C4 C5 C6 Moduel CON1 Moduel CON2


STP6 STP 1U 27P 0.1U R20 CON3
10K_1% 1 K_SCAN3 SW15
2 K_SCAN2 C7 C8 C9 C10
STP7 STP 3 K_SCAN1 1nF 1nF 1nF 1nF CAL
4 K_SCAN0
5 KEY 3 CAL
STP8 STP F2 R21 6 KEY 2
221 1K_1% 7 KEY 1 DISPLAY _VCC VDD3.3V
SEN- 1 3 AD_REF- 8 KEY 0
9
2

C11 C12 C13 10 ON_OFF R27


1U 27P 0.1U R26
KEY 330

1
10K_1% STP STP32
MEMBRANE
D9 JP2
DISPLAY _VCC VDD3.3V LOW_BAT
D10
JUMPER1

2
2
F3 F4 BUZ1 BUZ2 KDS184
221 221 1 1
LC_SIG+1 SIG+ LC_SIG-1 SIG- RTC_Power LOW_BAT BOOT0
3 3 2 2 3 2N2222
R29 1k Q1
2

C14 C15 C16 C17 SPEAKER SPEAKER R28 R30


27P 0.1U 27P 0.1U 2N2222 BUZZER 4.7k 10K
1

Q2

BT1
3.3V

ADC PART BUZZER PART RTC POWER SDI MODULE


STP12 STP STP15 STP STP23 STP STP29 STP
TXD2 485_CON K_SCAN3 KEY 1

STP13 STP STP16 STP STP24 STP STP30 STP


RXD2 EXT1 K_SCAN2 KEY 0

STP17 STP STP25 STP STP31 STP


JTMS K_SCAN1 ON_OFF

STP18 STP STP26 STP


JTCK K_SCAN0

STP19 STP STP27 STP


JTDI KEY 3

STP28 STP VDD3.3V

2
KEY 2
STP STP9 Y1 U12 VDD3.3V
32.768KHz 1 8
1 2 X1 VDD 7
STP STP14 3 X2 ACS 6
RTC_Power VBAK SCL I2C_SCL
4 5 I2C_SDA C32 C33
VSS SDA 0.1U 0.1U
VDD3.3V
221 F5 CON4-1 FM3130
U5 1 3 1
RX1_IN 1
TX1_OUT 1 3 2
2 2

C19 16 1 C18 3 2 VDD3.3V


VCC C1+ 221 F6 3
2 3 RX2_IN 1 3
105 V+ C1- 105 TX2_OUT 1221 CON5A CON5B U13
F7 3 L17 102 con-3p
2 2

221 F8 CON6-1 VDD3.3V 1 13 1 8


1 2 1 14 13 2 A0 VDD 7
1 +5V 2 14 A1 WP
TXD1 11 14 TX1_OUT 2 3 15 3 6
T1in T1out 2TX1_OUT 3 15 A2 SCL
RXD1 12 13 RX1_IN 3 4 16 4 5
R1out R1in 3 RX1_IN 4 16 VSS SDA
TXD2 5 17
TXD2 10 7 TX2_OUT L18 102 con-3p 6 5 18 17
RXD2 T2in T2out RX2_IN RXD2 6 18
9 8 485_CON 7 19 AT24C16
R2out R2in 8 7 20 19
EXT1 8 20
6 4 STP STP10 JTMS 9 21
C22 V- C2+ C23 10 9 22 21
JTCK 10 22
15 5 JTDI 11
105 GND C2- 105 STP STP11 12 11
12
STP45 STP header12x10 header12x10
ST3232CTR

VDD3.3V
STP35 STP36 STP37 STP38 STP39 STP44 STP40 STP41 STP42 STP43
STP STP STP STP STP STP STP STP STP STP

C24 SERIAL PART Title


105 CI-200 LED
Size Document Number Rev
CustomREV 0.8 0.6

Date: Friday , September 25, 2009 Sheet 2 of 3

1-2. Dispaly
LED1 LED2 LED3
7-SEGMENT 7-SEGMENT 7-SEGMENT
U1 ULN2003AD A 16 11 A A 16 11 A A 16 11 A
COM0 LED_COM B A A B B A A B B A A B
1
I1
16
O1 15
15
B D1 D2 B
10 15
B D1 D2 B
10 15
B D1 D2 B
10
COM1 2 CM1 C 3 A 8 C C 3 A 8 C C 3 A 8 C
COM2 I2 O2 14 CM2 D C C D D C C D D C C D
3
I3 O3 13
2
D F G B D
6 2
D F G B D
6 2
D F G B D
6
COM3 4 CM3 E 1 5 E E 1 5 E E 1 5 E
COM4 5 I4 O4 12 CM4 F 18 E E C E 12 F F 18 E E C E 12 F F 18 E E C E 12 F
COM5 6 I5 O5 11 CM5 G 17 F F 7 G G 17 F F 7 G G 17 F F 7 G
COM6 7 I6 O6 10 CM6 H 4 G D H G 9 H H 4 G D H G 9 H H 4 G D H G 9 H
I7 O7 H H H H H H
COM

COM

COM

COM

COM

COM

8 9
GND COM
14

13

14

13

14

13
CM6

CM5

CM4

CM3

CM2

CM1

D[7:0]
A R1 330 LED_COM
STABLE_LED D1
B R2 330
U2 74HC573 U3 74HC573 U4 TD62783AF TARE_LED D2
D0 2 19 COM0 D0 2 19 1 18 R3 100 A C R4 330
D1 3 D0 Q0 18 COM1 D1 3 D0 Q0 18 2 I1 Q1 17 R5 100 B G/N_LED D3
D2 4 D1 Q1 17 COM2 D2 4 D1 Q1 17 3 I2 Q2 16 R6 100 C D R7 330
D3 5 D2 Q2 16 COM3 D3 5 D2 Q2 16 4 I3 Q3 15 R8 100 D ZERO_LED D4
D4 6 D3 Q3 15 COM4 D4 6 D3 Q3 15 5 I4 Q4 14 R9 100 E E R10 330
D5 7 D4 Q4 14 COM5 D5 7 D4 Q4 14 6 I5 Q5 13 R11 100 F HOLD_LED D5
D6 8 D5 Q5 13 COM6 D6 8 D5 Q5 13 7 I6 Q6 12 R12 100 G F R13 330
D7 9 D6 Q6 12 D7 9 D6 Q6 12 8 I7 Q7 11 R14 100 H COMM_LED D6
1 D7 Q7 11 1 D7 Q7 11 9 I8 Q8 10 G R15 330
*OE LE 20 COM_CON *OE LE 20 DIGIT_CON V+ GND
10 VDD3.3V 10 VDD3.3V DISPLAY _VCC KG_LED D7
GND VCC C1 GND VCC C2 H R16 330
0.1U 0.1U G_LED D8
DISPLAY _VCC

C3
0.1U

61
Service Manual – CI200 REV NO :

1-3. Power
STP20 +9V VIN
STP STP22
STP
DC_IN VDD3.3V
U6 LM7809 U7
D11
XC6204C332MR
1 3 1

GND
IN OUT VIN 5

VSS
3 VOUT
SS14 C25 CE

2
CE1 0.1u + CE5 C26

2
CE2 100u/16V 100u/16 0.1u
100u/16V

R35 U8 MC34063A
0.22 1W
STP1
8 1 L13 220uH VDD3.3V
DC SWC
D12 D13
7 2
STP BD1 PK SWE R36
CN2 L15 D14 1N5406 102
SS14 SS14 D16 100k
2 1 6 3
1 VCC TCAP D15
3 KDS184
3 4 C27 SS14 1 2
2 POWER_CON R37 Power_chk
5 4 47p +5V
Adaptor LINE FILTER COMP GND CE3 2N2222

3
470u/35 Q3
R38 ON_OFF
STP46

3
20K SW17
22K

CE4 SW18 ON/OFF


470u/35 C28 R39 SW Charge

4
STP 0.1u R40 10K
2k

R42
R41 68k
47
STP2

STP Bat_chk
+5V
VIN U9
BATT
XC6204C502MR
CN3 R43 1
VIN

RECHARGERBLE BATTERY
FZ1 FUSE 49.9k 5

VSS
3 VOUT
3 1 2 STP47 CE
2 4 3 R44

점선 부분은 실크로 묶어 주세요


+ CE6 C29

2
1 2N2222 100u/16 0.1u
Pb BAT LC_PW_CE Q4
STP R45
20K
22K

AVCC5V +5V

L14 102
+9V +9V +9V
STP21
STP
DISPLAY_VCC
R46 R47 VIN U11
U10A 202 XC6204C502MR
8

333 1
3 VIN 5
+

VSS
1 3 VOUT
BATT CE
R49 2
- R50
+ CE7 C30

2
102 R48 104 2N2222 100u/16 0.1u
4

R33 DISPLAY_PW_CE
LM393 LED4 Q5
47K FG R52
R51 LED BI-COLOUR 20K
CV2 22K
103 +9V
R34
+9V
1

10K
R53
R32 CV3 R55
R54
104 U10B 47K 300
202
8

CV1
5
+
7
6
-
4

LM393

+9V

C31
0.1U

Title
<Title>

CHARGE INDICATION PART


Size Document Number Rev
A3 <Doc> <Rev Code>

Date: Friday , September 25, 2009 Sheet 3 of 3

Restrict the part shown in dotted line by silk.

62
Service Manual – CI200 REV NO :
2. CI201A(LCD)
2-1. Main & Display

AVCC5V
CN3 KEY 0 NUM1 NUM2 NUM3 NUM4
1 1 2 EX+ L11 102
2 1 2 EX- EX+ CAL CAL CAL CAL CON1 CON2
3 1 2 SEN+
SEN- AVCC5V 1 2 AVCC5V RTC_Power PA.0 33 34 PA.1 RTC_Power
4 1 2 + CE9
LC_SIG+ KEY 1 GND 3 4 GND Wk_Up PB.3 35 36 PB.0 BAT_CHK
5 1 2 L12 102 100u/16 NUM5 NUM6 NUM7 NUM8
LC_SIG- EX- SIG+ 5 6 SIG+ JTDO PB.4 37 38 PB.1 PB.0
6 1 2
SIG- 7 8 SIG- JNTRST 39 40 BUZZER
7 CAL CAL CAL CAL
L5 PB.5 PA.2
AD_REF+ 9 10 AD_REF- PB.5 PC.12 41 42 PA.3 TXD2
Loadcell L6
KEY 2 GND 11 12 GND CAL_SW 43 44 RXD2
L7 NUM9 NUM0 F_KEY 1 CLEAR1
GND 13 14 GND GND 45 46 GND
STP3 L8 R41 0
EX+ SEN+ VDD3.3V 15 16 VDD3.3V VDD3.3V 47 48 VDD3.3V
L9 CAL CAL CAL CAL
L10 PB.8 PA.11 PC.8 PC.7
PW_CHK PB.9 17 18 PA.12 PA.11 BL_CON PC.9 49 50 PC.6 K_SCAN3
STP BD6 102 R40 0
EX- SEN- KEY 3 PW_CON PB.10 19 20 PA.13 EXT1 485_CS PC.10 51 52 PC.5 K_SCAN2
STP4 F_KEY 2 SET1
LC_PW_CE PB.11 21 22 PA.14 JTMS PC.10 PC.11 53 54 PC.4 K_SCAN1
BL_PW_CE 23 24 JTCK DC_EN2 55 56 K_SCAN0
CAL CAL
STP PB.12 PA.15 PC.13 PC.3
K_SCAN0 PB.12 PB.13 25 26 JTDI TAMPER PA.8 57 58 PC.2 KEY 3
STP5 F1 R1 1 2 L1
K_SCAN1 LCD_CS PB.14 27 28 PB.6 BOOT0 PA8 PA.9 59 60 PC.1 KEY 2
221 10K_1% 1 2 L2
SEN+ 1 AD_REF+ K_SCAN2 LCD_WR PB.15 29 30 PB.7 I2C_SCL TXD1 PA.10 61 62 PC.0 KEY 1
3 1 2 L3
K_SCAN3 LCD_DATA 31 32 I2C_SDA RXD1 63 64 KEY 0
STP 1 2 L4
2

STP8 C6 C7 C8 Moduel CON1 Moduel CON2


1U 27P 0.1U R2 CN5
8.2K_1% 1 K_SCAN3
STP 2 K_SCAN2
STP6 3 K_SCAN1 C1 C2 C3 C4 CAL_KEY 1
4 K_SCAN0 1nF 1nF 1nF 1nF
KEY 3 CAL_SW
5
STP 6 KEY 2 CAL
STP7 F2 R3 7 KEY 1 VDD3.3V
221 10K_1% 8 KEY 0
SEN- 1 3 AD_REF- 9 STP43
STP 10 ON_OFF
2

C9
1U
C10
27P
C11
0.1U R4 STP KEY

1
10K_1% MEMBRANE

+5V_D VDD3.3V JP2


D1
BZ1 BZ2

2
KDS184 JUMPER1

2
F3 F4 3
221 221 Q1A
LC_SIG+1 SIG+ LC_SIG-1 SIG- RTC_Power BOOT0
3 3 2N2222 R12
BUZZER 4.7k
2

1
C12 C13 C14 C15 R13
27P 0.1U 27P 0.1U 10K
BT1
3.3V

ADC PART BUZZER PART RTC POWER SDI MODULE


STP13 STP18 STP25 VDD3.3V VDD3.3V VDD3.3V
TXD2 JTMS K_SCAN3
U9 VDD3.3V
STP STP STP CB2 1 8 CB3
2

STP16 STP20 STP27 2 X1 VDD 7 U2


RXD2 JTCK K_SCAN2 104 3 Y1 3 X2 ACS 6 104
VBAK SCL I2C_SCL
32.768KHz 4 5 C16 16 1 C18
RTC_Power VSS SDA I2C_SDA VCC C1+
STP STP STP 2 3
1

STP14 STP17 STP24 FM3130 +5V_D VDD3.3V 105 V+ C1- 105


485_CS JTDI K_SCAN1 VDD3.3V
OP1A
STP STP STP U10 1 TXD1 11 14 TX1_OUT
STP15 STP30 STP26 1 8 2 1 RXD1 12 T1in T1out 13 RX1_IN
EXT1 KEY 1 K_SCAN0 2 A0 VDD 7 3 2 R1out R1in
A1 WP TX1_OUT 3 TXD2 TX2_OUT
3 6 4 10 7
A2 SCL RX1_IN 4 RXD2 T2in T2out RX2_IN
STP STP STP 4 5 5 9 8
VSS SDA TXD2 5 R2out R2in
STP31
KEY 0
STP28
KEY 3 EEPROM PART AT24C16
RXD2
485_CS EXT1
6
7
8
6
7 C17
6
V- C2+
4
C19
EXT1 EXT2 8
STP STP 9 15 5
JTMS EXT3 9 GND C2-
STP32 STP29 10 105 105
ON_OFF KEY 2 JTCK EXT4 10
+5V_D 11
JTDI 11
LCD1A 12
Q5 KTA1666 STP STP U1 12 STP9 MAX3232c
3 2 1 48 1 STP34 header12x10
S7 SEG7 SEG8 S8 C0 D1
2 47 2 L14 102
S6 SEG6 SEG9 S9 C1 D2
3 46 3 STP46 STP
H6 H7 H8 H9 H10 H11 S5 SEG5 SEG10 S10 C2 D3
4 45 4 STP STP12 F5 221
1

S4 SEG4 SEG11 S11 C3 D4


R45 5 44 5 STP35 F6 221
S3 SEG3 SEG12 S12 S0 D5
100k 6 43 6 STP F7 221
S2 SEG2 SEG13 S13 S1 D6 OP1B cn4A
7 42 7 STP F8 221
1

S1 SEG1 SEG14 S14 S2 D7


8 41 8 STP 13 VDD3.3V 1 3 2
LCD_CS S0 SEG0 SEG15 S15 S3 D8 13 TX1_OUT 2
9 40 9 STP36 14 1 3 1

2 2
LCD_WR CS SEG16 S16 S4 D9 14 RX1_IN 1
R44 R7 10 39 10 15 3
LCD_DATA RD SEG17 S17 S5 D10 15 TX2_OUT 3
10k 101 11 38 11 16 1 3
WR SEG18 S18 S6 D11 16 RX2_IN
12 37 12 STP 17 CB1 1 3 con-3p

2 2
DATA SEG19 S19 S7 D12 17
13 36 13 STP37 18 cn6A
VSS SEG20 S20 S8 D13 18
R8 +5V_D 14 35 14 19 104 2
OSCO SEG21 S21 S9 D14 19 2
Q6A 101 R11 2.2k 15 34 15 20 STP10 1
OSCI SEG22 S22 S10 D15 20 1
R42 2N2222 8 7 16 33 16 STP 21 3
BK4 VLCD SEG23 S23 S11 D16 21 3
BL_CON 10k CE8 6 5 17 32 17 STP38 22
VDD SEG24 S12 D17 22
R9 4 3 18 31 18 STP con-3p
IRQ SEG25 S13 D18
101 2 1 19 30 19 STP11 L16 102
BZ SEG26 S14 D19
R43 100uF/16V 20 29 20 STP
LED_BL BZ SEG27 S15 D20
100K C5 21 28 21 STP39 header12x10
C0 COM0 SEG28 S16 D21
R10 DBB_BL41 104 22 27 22 STP
C1 COM1 SEG29 S17 D22
101
C2
C3
23
24 COM2
COM3
SEG30
SEG31
26
25
S18
S19
23
24
25
D23
D24
STP
STP40 STP41 STP42 STP33
SERIAL PART
S20 D25
HT1621b 26
S21 D26
27
S22 D27 Title
28 STP STP STP STP
S23 D28
OPTION BOARD CI-200 MAIN BOARD

DISPLAY
Size Document Number Rev

CONNECTION HOLE Custom

Date:
REV 1.0
Thursday , September 24, 2009 Sheet 1 of 1
0.6

63
Service Manual – CI200 REV NO :

2-2. Power
STP19

+P9V
U8 LM7809 STP
D6
1 3

GND
IN OUT
Charge SS14
+9V +5V_A
U5

2
CE3 XC6204C502MR
100u/16V 1
VIN 5

VSS
3 VOUT
STP1 CE
R14 U3 MC34063A + CE5 C25

2
0.33 2W C24 CE4 100u/16V 0.1u
STP 8 1 L13 220uH 0.1u 100u/16V
C22 DC SWC
D5 D7
0.1uF
7 2
BD5 PK SWE
CN1 L15 D3 1N5406 102
2 1 6 3 SS14 SS14
1 VCC TCAP D4
3 3 4 C23 SS14
2 5 4 470p LC_PW_CE
Adaptor LINE FILTER COMP GND CE2 Q3A
470u/35V
+5V_D R20 2N2222
33K
R21
STP47 CE1 C21 33k

3
470u/35 0.1u R17
R15 10K
STP 2k SW1
SW Charge STP21

4
STP
R16 STP2
47
VDD3.3V +9V +5V_D
STP R18 U4 XC6204C502MR
680k
1
VIN 5

VSS
R5 3 VOUT
BATT CE
Bat_chk 33k

2
CN2 FZ1 + CE7 C20
R19 Q2A 100u/16 0.1u
3 1 2 499k
2 4 3 2N2222
1
BAT FUSE
R6
33K

STP48
STP22

STP
STP

AVCC5V +5V_A

BD1 102 +9V VDD3.3V


U6
XC6204C332MR
1
+P9V +P9V +P9V BD2 102 VIN 5

VSS
Charge LED-Green P14 VOUT
3
CE
+ CE6 C26

2
R25 R30 100u/16 0.1u
U7A 202
8

333
3
+
BATT 1
R26 2 +5V_D
-
102 R33
R29 104
4

LM393 LED1 47K FG


CV2
R27 LED BI-COLOUR R24
Charge LED-Red P13
103 R34 D2 100k
+P9V +P9V
1

10K KDS184
1 2
R32 CV3 R35
R28 전원사양(+5V , Bat) PW_CHK
R31 47K 300

3
104 U7B +P9V PW_CON
202 CV1
8

Q4A
5 ON_OFF
+ 2N2222
7 CB4 R22
6 10K ON/OFF
-
104
R23 CAL
4

LM393 100k

Title
<Title>

CHARGE INDICATION PART RECHARGERBLE BATTERY


Size Document Number Rev
A3 <Doc> <Rev Code>

Date: Thursday , September 24, 2009 Sheet 1 of 1

64

You might also like