Professional Documents
Culture Documents
of Radon in air
2
that is activated only when the life depends on the operating
resonant filter detects an alpha mode and the ambient radiance
event, to optimize the energy level (5 days in natural radiation
consumption. without forced ventilation, > 12 ion
trajectory
hours with forced ventilation
The acquisition system has and 10 times radioactive higher
a double twisted 12-bit AD conditions).
A high voltage gradient in the
converter and a sampling rate at cell walls, which are to 3kV
3MS/s. Measurements can be carried respect to a silicon detector
Data are buffered by DMA, and out by diffusion or by forced mounted at the centre of
processed to identify pileup, suction from the soil using a the chamber, produces the
transport of the ionized fraction
cosmic rays and other spurious dedicated small tube. Depending
of 218Po atoms. Most of ions
events (beta/gamma/radio on the front door positions, the have to decay on the sensor.
noise). air intake from the outside to Ion mobility depends on air
the detection chamber can be pressure P and temperature
Data is readily integrated to performed in different ways recombination probability
depends on air humidity U and
calculate the energy, since
temperature T. alpha particle
the integration increases
the instrument’s resolution 222 positive ion
by significantly reducing the
218 Rn atom
uncertainty due to the peak
sampling.
Technical sheet
RADON SAMPLING:
Diffusion chamber
How to order
MEASUREMENT METHOD You can order your Ramona directly on line
Alpha Particles Spectrometry at www.ramona.eu or by e-mail at
info@ramona.eu
DETECTOR/SENSOR TYPE
Large active area Si PIN photodiode Payment
You can pay online via paypal with most
SENSITIVITY of credit cards or you can pay by banck
5.2 ∙ 10-4 CPM / (Bq/m3) transfer.
Ask further details at
OPERATION FLOW info@ramona.eu
Free flow, induction flow, pipe inlet, closed
Shipping
chamber We can ship Ramona worldwide. Ask for a
specific quotation at
SAMPLING FLOW RATE info@ramona.eu
0.5 l / min
www.ramona.eu
MEASUREMENT CYCLE TIME nfo@ramona.eu
since 20 minutes
Patent WO2010004366 A1 “Method and
CALIBRATION apparatus for the detection of the remote
Factory calibrated origin fraction of radon present in a
Environmental Sensors measuring site”
Relative Humidity
Temperature Patent US 8712700 B2 “Method and
Barometric Pressure apparatus for the detection of the remote
origin fraction of radon present in a
DATA STORAGE measuring site”
Non-volatile memory, Italian Design Model Nr. 0000103543 “Device
Micro SD Class 4 MicroSDHC for radon detection”
POWER SUPPLY
Mains power supply: 5 V, 5 Watt
Battery: 3 Cell (7.8 Ah)
INTERFACE Ramona is a product of
Ethernet, Wi-Fi
CONTROLS
Single switch, measurement/
Promete srl
stand-by Display
Piazzale Tecchio 45 · 80125 Napoli
DIMENSIONS tel +39 081 056850/51
164 x 161 x 173 mm promete@promete.it
WEIGHT
1,660 g ca. (with battery)
Realized under the project
NEST that has received
HOUSING funding from the Regione
ABS plastic Campania POR CAMPANIA
FESR 2014-2020 ASSE III,
OBIETTIVO SPECIFICO
3.4. AZIONE 3.4.2. Avviso
Additional information pubblico per la concessione
di contributi finalizzati al
finanziamento di programmi
PACKAGE CONTENTS di internazionalizzazione delle
Radon detector Micro e PMI campane.
Ramona Manual