You are on page 1of 32

UL LISTED & FM APPROVED

FIRE PUMPS AND SYSTEMS


FOR WHERE IT REALLY MATTERS

Scan the QR code and learn


about the SyncroFlo Inc. App
MULTI-STAGE
MULTI-OUTLET PUMPS
SyncroFlo Inc. is the first company to offer TYPICAL INSTALLATIONS:
• Offices
FM Approved multi-stage multi-outlet
• Hotels
(MSMO) pumps. Using multiple impellers to • Residential Buildings
generate more head than a single impeller, • Tunnels
MSMO pumps are used in fire protection • Mixed Use Buildings

systems in most tall buildings including TYPICAL APPLICATIONS:


offices, hospitals and hotels. • Sprinkler systems
• Hydrant systems
MSMO pumps offer many benefits: buildings need fewer pumps; • Deluge systems
pipework and valves are reduced; the need for water storage tanks • Monitor systems
on intermediate floors is eliminated; and the loading on the building • Water curtains
is reduced. The cost and space saving implications are significant:
power requirements are lower, pump rooms can be smaller and,
in line with new EU legislation, there is no need to use pressure
reducing valves to prevent over-pressurisation of sprinkler heads.

Driven by electric motors or diesel engines, SyncroFlo MSMO pumps


are available to satisfy any LPCB specification for automatic sprinkler
protection in high rise and multiple storey buildings.
END SUCTION PUMPS
The protection of life is not a matter for SyncroFlo FM/UL Unistream and Eurostream range of pumps
approved for fire protection by FM Approvals and Underwriter
compromise. This is particularly true for Laboratories and fully compliant to NFPA 20.
fire protection systems where they are
SyncroFlo End-Suction fire pumps are available for duties ranging
only as strong as their ‘weakest link’ and from 200 USgpm to 1500 USgpm and are suitable for electric or
compromise may result in avoidable loss diesel drives.
of life or property.
TYPICAL INSTALLATIONS:
That is why SyncroFlo fire pumps are designed specifically for the • Supermarkets
very particular needs of fire protection and are approved by most of • Hospitals
the major fire protection bodies around the world. By selecting an • Schools and Colleges
approved SyncroFlo fire pump as part of an approved system and • Hotels
maintained in accordance with standards such as NFPA 20,you can • Office Buildings
sleep easy knowing that you have chosen the best you can get.

SyncroFlo Pumps have been manufacturing fire pumps for over 135
TYPICAL APPLICATIONS:
• Sprinkler systems
years and with one of the widest range of approvals of any manufac-
• Hydrant systems
turer in the world. Experience gained from extreme environments
• Monitor systems
such as offshore oil & gas installations has led to the creation of the
• Water curtains
SPLIT CASE PUMPS
FM/UL Thrustream Split Case Fire Pumps TYPICAL INSTALLATIONS:
• Office buildings
have been manufacturing fire pumps for
• Hospitals
over 135 years with one of the widest • Airports
range of approvals of any manufacturer in • Manufacturing facilities
• Power stations
the world.
• Pharmaceutical facilities
Experience gained from extreme environments such as offshore oil • Schools/College
& gas installations has led to the creation of the SyncroFlo FM/UL
Thrustream range of fire pumps approved for fire protection by FM TYPICAL APPLICATIONS:
Approvals and Underwriter Laboratories. • Sprinkler systems
• Hydrant systems
SyncroFlo Thrustream FM/UL Approved Fire Pumps are available
• Deluge systems
for duties ranging from 200 USgpm to 5000 USgpm and are suitable
• Monitor systems
for electric or diesel drives. SyncroFlo also supplies Vertical, End-
• Water curtain
Suction and In-line pumps. SyncroFlo Thrustream FM/UL Approved
Fire Pumps are available with either inch or metric fittings.
VERTICAL TURBINES
Experience gained from extreme washdown or drill water. They can also be used for handling crude
oil or controlling spillages. For platform or jetty locations they can be
environments such as off-shore oil & gas provided with a below-deck discharge if required.
installations has led to the creation of the
SyncroFlo FM/UL Vertical Turbine range of TYPICAL INSTALLATIONS:
• Office Buildings
fire pumps approved for fire protection by
• Hospitals
FM Approvals and Underwriter Laborato- • Airports
ries and fully compliant to NFPA 20. • Manufacturing Facilities
• Power Stations
Where the fire protection water source is located below ground
• Pharmaceutical Facilities
or deck level, the best technical pumping solution is the vertical
suspended multi stage turbine pump. With this type of unit the im- TYPICAL APPLICATIONS:
pellers are fully immersed in the water maintaining prime at all times. • Sprinkler Systems
The pumps are driven by vertical electric motors or by diesel engines • Hydrant Systems
through a right angle gearbox. • Deluge Systems
SyncroFlo Vertical Turbine pumps can also be custom engineered for • Monitor Systems
the oil and gas industry and can handle fresh water or sea water for • Water Curtain
cooling purposes, fire protection duties, general water supply,
VERTICAL IN-LINE PUMPS
The SyncroFlo line of vertical In-Line fire TYPICAL INSTALLATIONS:
• Office buildings
pumps are lightweight and compact for
• Hospitals
smaller pump rooms. They eliminate the • Airports
need for coupling alignment and there • Manufacturing facilities
• Power stations
are fewer lost or misplaced parts.
• Pharmaceutical facilities
SyncroFlo Vertical In-Line Pumps are available for duties up to 1500
USgpm and are suitable for electric drives only. SyncroFlo Vertical TYPICAL APPLICATIONS:
In-Line pumps can also be offered as pre-wired packages that include • Sprinkler systems
a limited or full service controller. Every package is mounted on a • Hydrant systems
steel fabricated base with the motor wired to the controller. The auto- • Deluge systems
matic air relief valve, casing relief valve, suction gauge and discharge • Monitor systems
gauge are mounted on their respective spool pieces. Additional pip- • Water curtain
ing, valves and sensing lines are available with the In-Line packages.
The SyncroFlo In-Line package system also includes a jockey pump
and jockey pump controller.
PACKAGED FIRE PUMPS
SyncroFlo packaged fire pumping systems third party certification. Excellent design, quality construction and
knowledgeable personnel provide the reliability required for a
save time, labor and change orders on SyncroFlo Fire Protection System. SyncroFlo is ISO 9001 certified and
site. Cost-effective, completely self- our test rig is UL Listed and FM approved
contained skidded or housed units SyncroFlo can design your fire pump solution with electric or diesel
precisely fit specified areas, and require drivers. We offer inline, end suction, horizontal split case, or vertical
only system piping connections and a turbine pumps to meet site or flow requirements.

single point electrical hook-up. DETAILED SPECIFICATIONS:


Housings are built to accommodate required environments with • Built in accordance with NFPA Pamphlet 20
lighting, heating, ventilation, insulation, weather protection, alarms • Fully Prefabricated
and easy access opening. • Internally piped and wired
• Factory Installed Tamper Switches
Before shipment, each pump station must pass SyncroFlo’s unique
• Factory Tested
system testing and quality control standards. After installation, users
• Single Source Responsibility
are supported by a network of factory trained service representatives
• Automatic or Manual Operation
qualified to provide on-site system service and user training. All
SyncroFlo packages meet OSHA and Federal Regulation 29 CFR
1910.399 and NFPA Pamphlet 70 National Election Code (NEC) for
TOTAL COMMITMENT
Since 1962, our commitment to excellence has enabled
SyncroFlo to become the world’s leading manufacturer
of pumping stations. The SyncroFlo name has become
2905 Pacific Drive synonymous with quality-built, cost-effective pump-
Norcross, GA 30071 ing systems. We pioneered pre-assembled pumping
Te l : ( 7 7 0 ) 4 4 7 - 4 4 4 3 systems decades ago. Today, our installed base includes
w w w. s y n c r o f l o . c o m some of the largest pumping systems ever built.
A Kirloskar Company

FIRE PROTECTION
COMMERCIAL, INDUSTRIAL, POWER

PROVEN EXPERIENCE COMPLETE SYSTEM SINGLE SOURCE


With over 30 years of experience manufacturing pumping RESPONSIBILITY
systems for fire protection, SyncroFlo has a proven track When you have SyncroFlo products on your project, you truly
record of protecting life and property globally. SyncroFlo have total system single source responsibility. From inspection
packaged fire protection systems provide owners, engineers to commissioning, we provide complete system design. With
and operators a complete third party labeled system. a global network of factory certified technicians, startup
This is provided at an accurate predetermined cost, while commissioning and acceptance testing is just part of the
avoiding the pitfalls of site built systems. With a SyncroFlo service we provide. If any issues arise, from a ½” drain valve to
pre-engineered packaged system, all headaches are avoided a 300 HP diesel engine after installation, SyncroFlo is the only
by total coordination between the engineer, owner and phone call you need to make to get the problem solved and
SyncroFlo (the manufacturer). your system back online.

PACKAGED FIRE PROTECTION PUMPING QUALITY CONTROL AND TESTING


SYSTEM SOLUTIONS Every day, we strive to provide our clients with the highest
From the simplest single pump system to the most complex quality pumping systems. Our systems are manufactured in
multi-pump system with environmental enclosures, an ISO 9001-2008 certified facility in Norcross, GA. All systems
SyncroFlo packaged pumping systems are the solution to undergo quality inspection at each stage of the process
your specific application. Everything is designed to your in our 155,000 sq. ft. facility. These inspections include an
project specifications. Whether you have a small pump skid engineering review before the submittal and manufacturing
being installed in a pump room or a large industrial system process, as well as individual inspections at each stage of the
with multiple pump and driver combinations complete with manufacturing and assembly process. All quality inspection
enclosure, we have the right solution for you. All systems data is recorded on a hand-held device and uploaded via
are manufactured in accordance with NPFA 20 and NEC. The a web based app. With the major equipment pumps and
product arrives on site, ready to be installed and put into drivers being tested by the respective manufacturer, SyncroFlo
operation faster and more cost efficient than traditional site hydrostatically tests all piping in accordance with NFPA 20
built systems. requirements. Systems with enclosures receive a full test of all
ancillary equipment related to the pump system enclosure. We
also offer full witnessed factory acceptance testing in an NIST
FIRE - COMMERCIAL, INDUSTRIAL, POWER certified test facility.
SyncroFlo, Inc. 2905 Pacific Drive
Norcross, GA 30071
Tel: (770) 447-4443
www.syncroflo.com
A Kirloskar Company

FIRE - COMMERICAL, INDUSTRIAL, POWER


Exhaust Fans Thermostat Controlled
Unit Heater Hose Valve Header
Testing Device
City Water Bypass
Moisture/Dust Proof Light Fixtures
Flow Meter Testing Device

Automatic Air Release Valve


Jockey Pump Controller

Environmental Enclosures

Fire Pump Controller


1 or 2 hour Fire Walls

Welded Lifting Lugs


Step Down Transformer

4 Levels of Coating Systems


(to meet an enviromental requirement)

Electrical Motor or Diesel Flanged Customer Connections


Engine Driven Pumps

Welded Carbon Steel Jockey Pump NFPA 13 Sprinkler System


Skid Assembly

PUMP TYPES FEATURES


Flex Coupled End Suction, Veritcal Inline, • ETL Listed • Storage Tank Fill and Heating Systems
Horizontal Split Case & Vertical Turbine • In Accordance with NFPA 20 & NFPA 850 • Surge Protection and Pressure Reducing
• UL 508 Control Panels Systems
• 2, 3 & 4 Pump Designs • Environmental Enclosures
• Split Skid Configurations • 1 & 2-Hour Rated Fire Walls
PERFORMANCE • Common Suction & Discharge Headers • Systems for Classified Areas Available
• 3” - 24” Discharges • Electric Motor or Diesel Engine Driven • Coating Systems for Any Environmental
• Flow from 5,000 - 20,000 GPM Pumps Conditions
• Heads from 300 - 4500 PSI • Carbon Steel Piping • On Skid Backflow Prevention
• FBE Coated Carbon Steel Piping for Sea • On Skid Domestic and Irrigation Booster
Water Use Systems
• Common Suction & Discharge Headers • Foam Systems

FIRE - COMMERCIAL, INDUSTRIAL, POWER


3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case

QXJY.EX27101
Centrifugal Fire Pumps, Split Case
Page Bottom

Centrifugal Fire Pumps, Split Case

See General Information for Centrifugal Fire Pumps, Split Case

SYNCROFLO INC EX27101
2905 Pacific Dr
Norcross, GA 30071­1809 USA

Fire pumps, single stage, intended for installation with the shaft in a horizontal position
   
    Rated Net  Max Working 
Rated Capacity    Pressure Range  Approx Speed  Pressure 
(gpm) Size (in.) Model Dsg (psi) (rpm) (psi)

200 3 TB08D 96­149 3550 225

200 4 TD10E 98­169 2950 225

200 4 TD10E 109­187 3100 225

200 4 TD10E 140­210 3550 225

250 3 TB08D 94­147 3550 225

250 4 TD10E 97­168 2950 225

250 4 TD10E 108­186 3100 225

250 4 TD10E 139­209 3550 225

300 3 TB08D 93­145 3550 225

300 4 TD10E 96­167 2950 225

300 4 TD10E 106­185 3100 225

300 4 TD10E 138­207 3550 225

400 3 TB08D 87­139 3550 225

400 4 TB10D 105­144 3550 225

400 4 TD10E 134­205 3550 225

400 4 TD10E 92­164 2950 225

400 4 TD10E 102­182 3100 225

400 4 by 3 TB08F 88­139 3550 225

450 4 by 3 TB08F 87­135 3550 225

500 4 by 3 TB08F 85­131 3550 225

500 5 by 4 TD10F 162­260 3550 340

500 6 by 4 TB10F 90­174 3550 262

500 3 TB08D 81­133 3550 225

500 3 TB08E 54­104 3550 225

500 4 TB10D 102­139 3550 225

500 5 TB12D 112­148 3550 225

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 1/7
3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case
500 5 TC12F 43­49 1760 225

500 5 TC12F 48­72 2100 225

500 5 TC12F 53­92 2350 225

500 5 TC12F 67­113 2600 225

500 5 TC12F 118­208 3550 225

500 5 TC12G 138­193 3550 225

500 4 TD10E 66­99 2350 225

500 4 TD10E 68­124 2600 225

500 4 TD10E 86­158 2950 225

500 4 TD10E 97­176 3100 225

500 4 TD10E 129­200 3550 225

500 3 TE08D 128­195 2600 362.5

500 3 TE08D 152­229 2800 362.5

500 3 TE08D 133­257 2950 362.5

500 3 TE08D 139­268 3000 362.5

500 4 TE10D 44­90 1760 362.5

500 4 TE10D 65­122 2100 362.5

500 4 TE10D 72­137 2200 362.5

500 4 TE10D 81­150 2300 362.5

500 4 TE10D 87­162 2400 362.5

500 4 TE10D 96­176 2500 362.5

500 4 TE10D 104­193 2600 362.5

500 4 TE10D 121­229 2800 362.5

500 4 TE10D 131­247 2900 362.5

500 4 TE10D 135­255 2950 362.5

500 4 TE10D 141­264 3000 362.5

500 5 TE12E 72­131 2100 362.5

500 5 TE12E 80­143 2200 362.5

500 5 TE12E 87­158 2300 362.5

500 5 TE12E 97­171 2400 362.5

500 5 TE12E 104­187 2500 362.5

500 4 TB10E 81­108 3550 225

750 5 by 4 TD10F 154­251 3550 340

750 6 by 4 TB10F 85­160 3550 262

750 4 TB10E 69­95 3550 225

750 4 TB10D 95­129 3550 225

750 5 TB12D 106­144 3550 225

750 5 TB12E 85­113 3550 225

750 5 TC12F 54­82 2350 225

750 5 TC12F 59­104 2600 225

750 5 TC12F 74­134 2950 225

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 2/7
3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case
750 5 TC12F 111­199 3550 225

750 5 TC12G 111­142 2950 225

750 5 TC12G 130­185 3550 225

750 5 TD12F 44­54 1760 225

750 5 TD12F 49­81 2100 225

750 5 TD12F 62­103 2350 225

750 5 TD12F 95­165 2950 225

750 5 TD12F 141­208 3550 225

750 4 TE10D 82­108 2100 362.5

750 4 TE10D 62­122 2200 362.5

750 4 TE10D 69­137 2300 362.5

750 4 TE10D 77­149 2400 362.5

750 4 TE10D 85­164 2500 362.5

750 4 TE10D 94­179 2600 362.5

750 4 TE10D 112­216 2800 362.5

750 4 TE10D 121­233 2900 362.5

750 4 TE10D 124­243 2950 362.5

750 4 TE10D 131­252 3000 362.5

750 5 TE12E 90­121 2100 362.5

750 5 TE12E 70­134 2200 362.5

750 5 TE12E 78­148 2300 362.5

750 5 TE12E 88­162 2400 362.5

750 5 TE12E 97­178 2500 362.5

750 5 TE12E 105­193 2600 362.5

750 5 TE12E 124­227 2800 362.5

750 5 TE12E 136­245 2900 362.5

750 5 TE12E 141­255 2950 362.5

750 5 TE12E 146­264 3000 362.5

1000 8 by 6 TE15F 43­90 1760 225

1000 5 TB12E 80­107 3550 225

1000 5 TB12D 99­137 3550 225

1000 5 TC12G 100­131 2950 225

1000 5 TC12G 119­175 3550 225

1000 5 TD12F 60­73 2100 225

1000 5 TD12F 57­95 2350 225

1000 5 TD12F 72­121 2600 225

1000 5 TD12F 89­159 2950 225

1000 5 TD12F 134­199 3550 225

1000 6 TD15F 43­53 1760 225

1000 6 TD15F 74­128 2600 225

1000 6 TD15F 90­157 2800 225

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 3/7
3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case
1000 6 TD15F 97­171 2950 225

1000 5 TE12E 132­181 2600 362.5

1000 5 TE12E 159­213 2800 362.5

1000 5 TE12E 123­232 2900 362.5

1000 5 TE12E 128­240 2950 362.5

1000 5 TE12E 134­250 3000 362.5

1000 6 TE15D 54­87 1760 225

1000 6 TE15E 44­79 1760 225

1000 6 TE15E 85­145 1760 362.5

1000 6 TE15E 101­171 1900 362.5

1000 6 TE15E 126­208 2100 362.5

1000 6 TE15E 139­228 2200 362.5

1000 6 TE15E 152­251 2300 362.5

1000 6 TE15E 160­251 2350 362.5

1000 5 TB12F 105­145 3550 225

1000 8x6 TB15E 116­154 3550 225

1000 6 by 5 TA12D 59­105 3550 213

1250 8 by 6 TE15F 40­86 1760 225

1250 5 TB12F 99­137 3550 225

1250 5 TD12F 82­148 2950 225

1250 5 TD12F 125­191 3550 225

1250 6 TD15F 62­100 2350 225

1250 6 TD15F 70­123 2600 225

1250 6 TD15F 84­150 2800 225

1250 6 TD15F 93­164 2950 225

1250 6 TD15F 137­191 3550 225

1250 8 TD20E 96­174 2800 305

1250 8 TD20E 108­196 2950 305

1250 6 TE15D 50­81 1760 225

1250 6 TE15E 59­74 1760 225

1250 6 TF15E 81­142 1760 362.5

1250 6 TF15E 97­166 1900 362.5

1250 6 TF15E 122­203 2100 362.5

1250 6 TF15E 134­225 2200 362.5

1250 6 TF15E 148­246 2300 362.5

1250 6 TF15E 155­246 2350 362.5

1250 8x6 TB15E 112­150 3550 225

1250 8x6 TB15F 95­143 3550 225

1250 8x6 TF15G 60­128 1760 363

1500 8 by 6 TF15H 80­162 1760 363

1500 8 by 6 TE15G 68­108 1760 225

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 4/7
3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case
1500 8x6 TB15E 108­142 3550 225

1500 8x6 TB15F 91­136 3550 225

1500 6 TD15F 57­94 2370 225

1500 6 TD15F 64­116 2600 225

1500 6 TD15F 78­144 2800 225

1500 6 TD15F 88­157 2950 225

1500 6 TD15F 133­187 3550 225

1500 8 TD20D 47­60 1760 305

1500 8 TD20D 110­179 2800 305

1500 8 TD20E 41­55 1760 305

1500 8 TD20E 45­87 2100 305

1500 8 TD20E 72­112 2350 305

1500 8 TD20E 91­169 2800 305

1500 8 TD20E 105­190 2950 305

1500 8 TD20E 154­202 3550 305

1500 6 TE15D 67­76 1760 225

1500 6 TF15E 108­136 1760 362.5

1500 6 TF15E 115­162 1900 362.5

1500 6 TF15E 116­199 2100 362.5

1500 6 TF15E 128­220 2200 362.5

1500 6 TF15E 143­241 2300 362.5

1500 6 TF15E 151­243 2350 362.5

1500 10x8 TF20F 81­140 1760 235

1500 10x8 TF20G 71­138 1780 235

1500 8 by 6 TF15G 85­120 1760 363

2000 10 by 8 TF20J 107­149 1760 235

2000 8 by 6 TF15H 105­150 1760 363

2000 8 by 6 TE15G 65­103 1760 225

2000 10x8 TE20D 114­160 2350 260

2000 10x8 TE20D 89­125 2100 260

2000 10x8 TE20D 62­81 1760 260

2000 10x8 TE20A 50­94 1760 260

2000 8 TD20D 58­82 2100 305

2000 8 TD20D 56­108 2370 305

2000 8 TD20D 73­138 2605 305

2000 8 TD20D 104­174 2800 305

2000 8 TD20D 97­197 2960 305

2000 8 TD20E 63­101 2390 305

2000 8 TD20E 69­130 2600 305

2000 8 TD20E 84­159 2800 305

2000 8 TD20E 95­179 2950 305

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 5/7
3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case
2000 8 TD20E 147­196 3550 305

2000 10x8 TF20D 94­150 1760 235

2000 10x8 TF20E 80­142 1760 235

2000 10x8 TF20F 77­133 1760 235

2000 10x8 TF20G 65­127 1780 235

2000 10x10 TD25A 41­72 1760 232

2500 10 by 8 TF20J 100­141 1760 235

2500 10x10 TD25A 46­68 1760 232

2500 12x10 TE25D 82­146 2100 250

2500 10x8 TE20D 108­153 2350 260

2500 10x8 TE20D 83­117 2100 260

2500 10x8 TE20A 75­89 1760 260

2500 8 TD20D 95­164 2800 305

2500 8 TD20D 102­188 2960 305

2500 10x8 TF20D 87­146 1760 235

2500 10x8 TF20E 75­134 1760 235

2500 10x8 TF20F 76­123 1760 235

2500 10x8 TF20G 104­160 2100 300

2500 12 TE25A 73­114 1760 232

3000 12x10 TE25D 80­142 2100 250

3000 10x8 TE20D 100­144 2350 260

3000 12 TE25A 69­111 1760 232

3000 10x8 TF20D 82­138 1760 235

3500 12x10 TE25D 77­137 2100 250

Fire pumps, multistage
 
    Rated Net  Max Working 
Rated Capacity    Pressure Range  Approx Speed  Pressure 
(gpm) Size (in.) Model Dsg No. of Stages (psi) (rpm) (psi)

500 5 TY12D 2 145­191 1760 450

500 5 TY12D 2 173­223 1900 450

500 5 TY12D 2 214­276 2100 450

500 5 TY12D 2 260­334 2300 450

500 5 TY12D 2 273­350 2350 450

500 5 TX12D 2 256­330 2950 450

500 6 TX15E 2 277­370 2950 478

500 6 TY15E 2 300­375 2350 478

500 6 TY15E 2 288­360 2300 478

500 6 TY15E 2 240­298 2100 478

500 6 TY15E 2 195­242 1900 478

500 6 TY15E 2 171­210 1760 478

500 6 TX15F 2 283­378 2950 478

750 5 TY12D 2 163­200 1900 450

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 6/7
3/22/2017 QXJY.EX27101 ­ Centrifugal Fire Pumps, Split Case

750 5 TY12D 2 190­250 2100 450

750 5 TY12D 2 240­312 2300 450

750 5 TY12D 2 250­328 2350 450

750 5 TX12D 2 230­300 2950 450

750 6 TX15E 2 268­360 2950 478

750 6 TY15E 2 296­370 2350 478

750 6 TY15E 2 284­353 2300 478

750 6 TY15E 2 235­294 2100 478

750 6 TY15E 2 190­237 1900 478

750 6 TY15E 2 166­205 1760 478

750 6 TX15F 2 276­370 2950 478

1000 6 TX15E 2 254­346 2950 478

1000 6 TY15E 2 291­361 2350 478

1000 6 TY15E 2 278­345 2300 478

1000 6 TY15E 2 227­285 2100 478

1000 6 TY15E 2 181­230 1900 478

1000 6 TY15E 2 155­196 1760 478

1000 6 TX15F 2 268­361 2950 478

1250 6 TX15E 2 275­329 2950 478

1250 6 TY15E 2 278­347 2350 478

1250 6 TY15E 2 265­331 2300 478

1250 6 TY15E 2 214­274 2100 478

1250 6 TY15E 2 170­215 1900 478

1250 6 TX15F 2 246­348 2950 478

A suffix "H" is added to the model designations given above for installations with high inlet pressure but in no case shall the maximum allowable
discharge values given above be exceeded.

Last Updated on 2016­04­21

Questions? Print this page Terms of Use Page Top

© 2017 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow­Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non­
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in
the following format: "© 2017 UL LLC".

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXJY.EX27101&ccnshorttitle=Centrifugal+Fire+Pumps,+Split+C… 7/7
5/30/2017 QXCZ.EX27102 ­ Centrifugal Fire Pumps, In­line

QXCZ.EX27102
Centrifugal Fire Pumps, In­line
Page Bottom

Centrifugal Fire Pumps, In­line

See General Information for Centrifugal Fire Pumps, In­line

SYNCROFLO INC EX27102
2905 Pacific Dr
Norcross, GA 30071­1809 USA

    Rated Net   Max
Rated     Pressure Approx Working
Capacity Size Model Range Speed Pressure
GPM In. Dsg psi RPM psi

150 2 by 2 KFL05D 52­115 3500 206

200 3 by 3 KFL08D 56­121 3500 198

250 3 by 3 KFL08C 41­83 3500 206

250 3 by 3 KFL08D 54­120 3500 198

250 3 by 3 KFL08X 69­130 3500 211

300 3 by 3 KFL08D 50­118 3500 198

400 5 by 4 KFL10X 96­132 3500 222

450 5 by 4 KFL10X 93­130 3500 222

500 5 by 4 KFL10X 89­128 3500 222

750 6 by 6 KFL15E 70­146 3550 232

1000 8 by 8 KFL20E 67­115 3550 239

1250 8 by 8 KFL20H 86­122 1775 217

1250 8 by 8 KFL20F 68­79 1775 213

1500 8 by 8 KFL20H 81­116 1775 217

1500 8 by 8 KFL20F 64­75 1775 213

Last Updated on 2016­04­06

Questions? Print this page Terms of Use Page Top

© 2017 UL LLC

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow­Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­Up
Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non­
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory
with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in
the following format: "© 2017 UL LLC".

http://database.ul.com/cgi­bin/XYV/template/LISEXT/1FRAME/showpage.html?name=QXCZ.EX27102&ccnshorttitle=Centrifugal+Fire+Pumps,+In­line&… 1/1


6\QFUR)OR,QF
3DFLILF'ULYH1RUFURVV*HRUJLD86$ 
5DWHG1HW 5DWHG1HW
5DWHG 5DWHG +HDGDW +HDGDW 5DWHG 6XFWLRQ 'LVFKDUJH
/LVWLQJ &HUWLILFDWLRQ
3URGXFW  &DSDFLW\ &DSDFLW\ 5DWHG 5DWHG 6SHHG ,QOHW 2XWOHW 6WDJH V
&RXQWU\ 7\SH
JDOPLQ  GPñPLQ &DSDFLW\ &DSDFLW\ UPLQ GLDLQ GLDLQ
SVL N3D
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7&)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7($ 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7&)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7;' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&* 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
7&) 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7&)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7&)          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7&)          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&* 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&) 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7&)          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7($ 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&* 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&) 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7;' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7<' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7((          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7(( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&* 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;(          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7;)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
7%' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
7&* 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7((          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7;)          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7<(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7)( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7))          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7''          )0$SSURYHG
RI
$PHULFD
8QLWHG
7') 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7''          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7))          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'(          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'$          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7''          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7''          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)'          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)'          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'( 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
7'' 6WDWHV
‚          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'$          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7($          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)(          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7))          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)'          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7($          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7'$          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7($          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7($          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7('          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7$'          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7%)          )0$SSURYHG
RI
$PHULFD

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI


8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7')          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7()          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7()          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)+          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)+          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7(*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7(*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)-          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)-          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)*          )0$SSURYHG
RI
$PHULFD
8QLWHG
6WDWHV
7)*          )0$SSURYHG
RI
$PHULFD

‚7KHVHGHVLJQDWLRQVKDYH )0 IROORZLQJWKHGHVLJQDWLRQQXPEHU

7LDQMLQ3X\RX0HFKDQLFDO (OHFWULFDO(TXLSPHQW&RUSRUDWLRQ
1R%HMLQJ6W-LQQDQ(FRQRPLF'HYHORSPHQW$UHD 6KXDQJJDQJ 7LDQMLQ
5DWHG 5DWHG
5DWHG 5DWHG 1HW+HDG 1HW+HDG 5DWHG 6XFWLRQ 'LVFKDUJH
/LVWLQJ &HUWLILFDWLRQ
3URGXFW  &DSDFLW\ &DSDFLW\ DW5DWHG DW5DWHG 6SHHG ,QOHW 2XWOHW 6WDJH V
&RXQWU\ 7\SH
JDOPLQ  GPñPLQ &DSDFLW\ &DSDFLW\ UPLQ GLDLQ GLDLQ
SVL N3D
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG
+63  &KLQD         )0$SSURYHG

‹)0$SSURYDOV$OOULJKWVUHVHUYHG RI

You might also like