Used in the products Represents the Used in the products Represents the products Represents the
that are a step further products of energy that have smart which are easy-to-use “green” products that
than their counterparts continuity and control logic and where difficult tasks respect the nature
measurable energy are made easier and our future
efficiency
2
Metering & Management
ActWin Smart Metering Software................................................................................................ 8-10
GPRS Communication Units - NCP12 .............................................................................................. 11
MV Products
Metal Enclosed Switchgear - SME .................................................................................................. 34
Metal Clad Switchgears - SNC ........................................................................................................ 36
Metal Clad Switchgears - SMC ........................................................................................................ 38
Rotary Disconnectors - SRS............................................................................................................. 40
Earthing Switches - SES................................................................................................................... 41
Neutral Grounding Resistors - SRG.................................................................................................. 42
Load Banks - SRL............................................................................................................................. 43
MV Substations
Compact Substations made by Steel Sheet - SCK ........................................................................... 46
Compact Substations made by Concrete - SMK .............................................................................. 47
Compact Solar Substations - RST..................................................................................................... 48
Mobile Substations - SMS............................................................................................................... 49
Power Converters
Modular Type Solar Inverters................................................................................................................52
String Boxes...........................................................................................................................................53
3
Companies & Shareholders
Friem S.p.A.
Friem manufactured over 40 million ampere and 1000 power
rectifiers for the worldwide since it’s established in Milan at 1950.
Having technical knowledge of energy and electro mechanics
along with ability of complete design of conversion systems,
Friem provides also HV DC insulators, DC switches, anodic control
and protection products and Renewable Energy Inverters to its
customers.
Friem is a share holder of Aktif Elektronik in Turkey and also COET
S.r.L in Italy.
Coet S.r.L.
Since establishment in 1962 in Milan, Coet has been producing
AC / DC switching equipments and panels that are used safely by
its customers thanks to the Coet’s work on industrial and electric
equipment and patents obtained in this field.
Coet has been working on Industrial and railway systems and has
become one of the leading companies in the field of supplying
switching equipments for traction substation.
4
Aktif Values
Vision Statement
Energy is one of the basic requirements for worldwide economic
development but the greenhouse gases effect depends to great
extent on how the energy is produced. We, as AKTİF Group, do
endorse Global compact and sustainable development as one of
the pillars of our business approach.
We want to be recognized by our stakeholders as the very best
performer in competitive energy market in order to achieve the
greatest possible returns by innovating, designing, expositing and
placing competitive products and services for sustainable and
habitable environment by enhancing the standards of living for our
planet.
Mision Statement
In order to contribute our stakeholders’ success and to improve
our footprint in terms of technology, price, quality, environment
and delivery performances, our mission is to bring the most
competitive product and service solutions making energy simple
for our customers through with offering possible broadest
portfolio.
Aktif Values
AKTİF values are the group commitment to our customers, our
employees, our shareholders and all of the communities at which
we play role directly or indirectly.
Our Values are;
· Customer satisfaction
· Loyalty
· Profitability
· Liability
· Totality
· Equity
· Corporation
Service Continuity
The service continuity means efficiency of power and consequently,
the profitability of the business.
Our products are designed and manufactured in order to ensure
energy sustainability and provide the best service availability.
5
Metering & Management
ActWin Smart Metering Software...................................................................................................................... 8-10
GPRS Communication Units - NCP12 .................................................................................................................... 11
6
A
Metering &
Management
Energy
Industry
Building
Solar Systems
7
ActWin Smart Metering Software
Software Modules:
• Communication and data validation
• Reporting
• Billing
• Loss/Leakage Detection
• Single-Line Diagram and Map presentation
• Integration with web services
• Alarm Management, SMS and e-mail notification
• Internet interface
• User Management and Inventory Communication
• Authentication Actwin Smart has modular structure to provide different new
protocols to be found in the future. Supported protocols are listed
below.
Communication principle is compatible with “push” and “pull”
structure. Data collection schedule, result saving to the database
schedule can be defined and measurement parameters that will be
read from each the device can be defined independently.
Communication module starts automatically when server starts as
windows service. This prevents users from accidently closing the
data collection application.
Communication Protocols:
• IEC 62056-21 Mod C and constant baud rate
• DLMS/Cosem
• Modbus-RTU
• Modbus-TCP/IP
• M-Bus
• Wireless M-Bus
Communication Interfaces :
• Serial communication (RS485, RS232)
• GPRS
• M-Bus
• Ethernet
• PLC (DLC)
• RF
8
ActWin Smart Metering Software
Reporting
Reports can be prepared as below with collected data. The modular
structure provides capability to add new reports to the software
when needed. There is no need to upgrade or modify the software
when a new report is requested. All reports can be exported as MS
Excel, MS Word, HTML and PDF.
• Reporting as a table of all selected device measurements.
Also measurements to be reported can be selected.
• Graphic display of desired device measurements. Multiple
device measurements can be drawn on the same chart.
• Measurement points can be compared with algorithms like
consumption, average values etc…
• Active and reactive energy ratio reports for electricity meters.
• Consumption reporting for electricity meters according to
energy tariffs.
• Distribution network load reports (Transformer, gas stations)
• Measurement point daily, monthly, and yearly consumption
reports.
• Map display, showing the measurement points with filters
(Reactive energy, low consumption, loss/fraud situations, no
communicated points etc…).
• Transformer loss report
• Total consumption of distribution network as monthly and
yearly, import/export with comparison between time periods.
• Defined gas component reports.
• Natural gas minimum/maximum hourly, daily consumption
report.
• Measurement point inventory report
• Measurement point communication performance report
• Water meters low/extreme consumption report Loss/Leakage Detection
• Loss/Leakage reports can be prepared manually and
automatically. Automatically prepared reports can be sent to
defined person as e-mail.
• Electricity meter parameters (events, current/voltage/power/
power factor/phase angle etc…) can be monitored continuously
and alert operators if an unexpected measurement or ratio is
measured.
• Unexpected consumption differences are detected between
main distribution points and points connected to that
distribution point.
• The interventions to meter and panel covers can be detected
and operators can be alerted.
Data Validation
Measurements should not be used on invoices and reports before
data validation. For that reason some data validation methods like
below are used.
• Is measurement in or not in specific limits
• The ratio of measurement according to previous periods
consumptions
• The change ratio according to last measurements
• Is measurement in or not in standard deviation according to
average value of last billing periods
• Check between measurement unit and measurement
Integration
Synchronization to other systems like ERP, accounting, geographic
informative, bank etc… can be provided with Web Services.
9
ActWin Smart Metering Software
Single-line Diagram
• Electrical distribution network can be showed on single-line
diagrams like SCADA systems and the information of
instruments like electrical meters, seconder protection relays
on this network can be monitored.
• Electrical meter’s power-current/voltage values, secondary
protection relay’s on/trip situations and quality recorder’s Web Interface
power-current/voltage values can be monitored with digital
and analog instrument display. Internet interface have customers monitor their own consumptions
• Gas meters, measurement values, filter impurity situations, and energy quality parameters. Reaching to interface is done by
door/valve situations belong to type B and C stations can be entering username and password and users can only reach their
displayed. own measurement points.
• Drag and drop support.
• Infinite number of screens can be created. For security, there is no direct connection through the system
in internet. There is a safe web service level between internet
interface and database.
• Users can view historical measurement values of their own
measurement points
• Users can view common or personal messages from
management.
• Natural gas consumers can send to AMR system their forecasts
and check their forecasts reports.
• Users may have alerts like reactive penalty, maximum demand
exceeding, minimum and maximum gas consumption.
Authorization
• The roles can be defined with the pre-defined permissions on
system. Users can be defined and roles can assigned to users.
• Operators can make authentication based on measurement
points. They can define which users can reach to which
measurement points.
Alarm Management
• Event record on measurement instruments can be saved and
reported on database.
• System watches reactive energy consumptions and if there is
a measurement or over the limits, system informs
the users with e-mail and SMS.
• E-mail and SMS notification can be saved on database and
reported later.
10
GPRS Communication Units - NCP12
Technical Features:
• ARM Cortex M3 processor, Telit GSM/GPRS module
• 1 MB internal memory
• 85 – 265 Vac, 120 – 370 Vdc auxiliary supply
• 2 pcs digital output (expandable and can be used as relay
output)
• 2 pcs digital input (expandable)
• 25F Super capacitor to notify energy cut off while de-energized
for 15 minutes.
• Remote firmware update
X X X - M X - C X
0 2 Digital Input / 2 Digital Output
R 2 Digital Input / 2 Relay Output
0 Reusable Battery
L Supercap
0 Expansion Module
M Wired M-Bus (for mechanical meter)
Z Zigbee Communication Module
NCP12 0
1
Standard Memory
1 GB Memory
2 2 GB Memory
4 4 GB Memory
4 2 and 4 Wired Cascaded RS485
E 2 Wired RS485 and Ethernet
11
Medical Power Solutions
Isolated Power Distribution Panel - IGTP..............................................................................................................14
Isolated Power System..........................................................................................................................................15
Medical Isolating Transformers - IT.......................................................................................................................16
Operating Theater Control Panels - OCP...............................................................................................................17
12
B
Medical Power
Solutions
Medical Plants
13
Isolated Power Distribution Panel - IGTP
Technical Specifications:
• Power of system 3.15 / 4 / 5 / 6.3 / 8 / 10 kVA
• According to IEC 60364-7-710
• Monitoring insulation resistance, load current and IGTP
temperature of the transformer
• Dimension of panel 500 x 500 x1750 mm
• Color of panel RAL 7035 / RAL 9003
Technical Specifications
Brand name AKTİF
Type IGTHP 0710/1P-XX
Standards IEC 60364-7-710: 2002-11
Rated power of outgoing 3.15 / 4 / 5 / 6.3 / 8 / 10 kVA
Power supply unit Double single phase lines
Rated voltage line 1 230 Vac
Rated voltage line 2 230 Vac
Rated frequency 50 / 60 Hz
Rated insulation level 3 kV / 1 min
Input protection gL fuse
Secondary output voltage 230 Vac
Output protection 2 pole fuses
Monitoring isolation resistance with LCD display
Alarm output isolation fault, excessive load,
excessive temperature,
switchover failure
Functional Test advanced isolation fault and
switchover test
Leakage current to enclosure < 0,5 mA
IT system with insulation monitoring by ISOMETER® isoMED427P Response range 50 - 500 kΩ
Isolation fault detection time <1s
Switchover time < 200 ms
Operating temperature 5........+50 °C
Storage temperature 25......+60 °C
Panel sizes 500x500x1750 mm
Distribution outlet 6 - 12 pieces as standard
Cooling system With double fan
Protection class IP 31
Color RAL 7035 / RAL 9003
14
Isolated Power System
System functions:
• Indication of faulty branch circuits.
• Easily retrofitting with existing installations due to the
modular design.
• Measuring current transformers in different sizes and
designs.
• Up to 528 sub circuits can be monitored.
• Communication via two-wire connection.
• Universally applicable for all IT systems.
15
Medical Isolating Transformers - IT
IT 0710
Standard Version
General Features
Brand ASSET
Type IT 0710
Power range 3.15 / 4 / 5 / 6.3 / 8 / 10 kVA
Frequency 50 / 60 Hz
Primary Voltage 230 Vac
Secondary Voltage 230 Vac
Inrush current (Ie) < 12.In
Leakage current < 0,5 mA
No-load input current (Io) < 3%
No-load output voltage (Uo) < 236 V
Short-circuit voltage (Uk) < 3%
Operating mode continuous operation
Connections separate terminal block
Max ambient temp. 40 ° C
Isolation class 40/B
Cooling Air cooling
PTC resistor 1 resistor per transformer winding
Dimension diagram IT 0710
Protection class IP 00
Standards IEC 603647-710, IEC 61558-2-15
16
Operating Theater Control Panels - OCP
OCP 10
Technical Specifications:
• 4 line general illumination control
• Control of operation lamp
• Negatoscope control
• 4 channel music broadcast channel selection
• Digital clock and chronometer
• 10 channel medical gas alarm panel
• Temperature, humidity, room difference pressure, hepa filter
pollution indicator
• Temperature monitoring and setting, audible and luminous
warning when set value is exceeded.
• Command for Operating room exists/not exist, flow control
• Damper open-close manual control
• Electricity heater control
17
Power Quality Solutions
Power Quality Engineering................................................................................................................................... 20
Harmonic Filter Reactors - AR ............................................................................................................................. 21
Shunt Reactors - SR.............................................................................................................................................. 22
Shunt Reactor Banks - SRS ................................................................................................................................... 23
Compensation Rack Units - P5............................................................................................................................. 24
Compensation Rack Units - R7 ............................................................................................................................ 25
Compensation Rack Units - R7s............................................................................................................................ 26
Capacitor Banks - M............................................................................................................................................. 27
Capacitor Banks with detuned harmonic filters - MS .......................................................................................... 28
Thyristor controlled capacitor banks with detuned filters ................................................................................... 29
HV Capacitor Banks - MLC ................................................................................................................................... 30
Static Electronic Switches - Thymod .................................................................................................................... 31
18
C
Power Quality
Solutions
Energy
Industry
Building
Solar Systems
19
Power Quality Engineering
Advantages:
• Analyzing electric network and determining the problems.
• Designing best solutions according measurement data.
• Reactive penalty is prevented.
• Applying individual compensation in systems with many
distributed loads with reactive power requirements is the
most economic solution.
• It allows more effective usage of the transformer.
• It reliefs the transformer.
• Current Measurements
Irms, IR, IS, IT, I0, IPOZ, INEG
20
Harmonic Filter Reactors - AR
Product Advantages:
• Manufacturing according to customer’s request
• Aluminum and copper coil options
• Easy mounting to different type of panels
• High quality and long life period
Technical Specifications:
• Rated Voltages : 230 … 1000 V AC
• Rated Frequency : 50 / 60 Hz
• Resonance Frequency : 134 / 189 / 210 / 225 Hz
• Degree of protection : IP 00 AR3 4450-F70
• Power Range : 0,83 … 150 kVAr
• Over Current : 1,35 x In
• Linearity Current : 2,1 x In
• Inductance Tolerance : Max %3
• Rated Temperature : ta 40 oC
• Standards : EN 61558-1 , EN 60076-6, VDE 0550
21
Shunt Reactors - SR
Product Advantages:
• Manufacturing according to customer’s request
• Aluminum and copper coil options
• Easy mounting to different type of panels
• High quality and long life period
Technical Specifications:
• Rated Voltages : 230 … 1000 V AC
• Rated Frequency : 50 / 60 Hz
• Degree of protection : IP 00
• Power Range : 0,1 … 50 kVAr SR - 5040
• Over Current : 1,35 x In
• Linearity Current : 2,35 x In
• Inductance Tolerance : Max %3
• Rated Temperature : ta 40 oC
• Standards : EN 61558-1 , EN 60076-6, VDE 0550
Reactors are also available with your requirements and specs.
Please contact with us.
Monunting Monunting
Power Nominal Phase Aktif Model L (mH) Irms (A) Ilin (A)
Width Depth Height
Width Depth
Mounting Weight
(kVAr) Voltage Number Type (mm) (mm) (mm)
(mm) (mm)
Hole (mm) (kg)
(V)
A C B D H d
1 400 3 SR-140 3x509,27 1,73 2,89 240 175 220 130 94 8,5x17 18,1
2 400 3 SR-240 3x254,63 3,46 5,77 240 175 220 130 114 8,5x17 25,3
5 400 3 SR-540 3x101,85 8,66 14,43 300 220 280 170 150 8,5x17 50,9
10 400 3 SR-1040 3x50,92 17,32 28,87 360 250 260 200 170 8,5x17 78,0
25 400 3 SR-2540 3x20,37 43,30 72,17 480 215 360 250 175 11x26 140,2
22
Shunt Reactor Banks - SRS
Product Advantages:
• Designed for different voltage and power levels
• It helps us in installation and maintenance period thanks to its
moduler design
• Remote monitoring and controlling with Scada system
• Power can be increased by adding panels thanks to it is
moduler design
Technical Specifications:
• Rated Voltages : 400/690 V
• Rated Frequency : 50/60 Hz
• Max Power for 1 panel : 100 kVAr
• Ambient temperature : -40°C / 55°C
• Mechanical resistance for high short circuit powers
SRS- 10040
Dimensions:
23
Compensation Rack Units - P5
Product Advantages:
• It helps us in installation and maintenance period thanks to its
modular design.
• Withstand 1,18 x Vn over voltage and 1,50 x In over current
thanks to Asset VCB series capacitors.
• No additional material is required.
Technical Specifications:
• Rated Voltage : 400/415 V*
• Nominal Frequency : 50/60 Hz
• Environment Temperature : -10… +45 °C
• Switching : by Contactor
24
Compensation Rack Units - R7
Product Advantages:
• It helps us in installation and maintenance period thanks to its
modular design.
• Withstand 1,18 x Vn over voltage and 1,50 x In over current
thanks to Asset VCB series capacitors.
• No additional material is required.
• Compensation rack has harmonic filter reactor which protects
capacitors against to harmonics.
Technical Specifications:
• Rated Voltage : 400 / 415 V*
• Nominal Frequency : 50/60 Hz
• Resonance Frequency : 189 Hz, 210 Hz, 215 Hz
• Switching : by Contactor
25
Compensation Rack Units - R7s
R7s-500044
Product Advantages:
• It helps us in installation and maintenance period thanks to its
modular design.
• It has strength 1,18 x Vn over voltage and 1,50 x In over current
thanks to VCB series capacitors.
• Protection against to harmonics.
• Fast switching.
Technical Specifications:
• Rated Voltage : 400 / 415 V*
• Nominal Frequency : 50/60 Hz
• Resonance Frequency : 189 Hz, 210 Hz, 215 Hz
• Switching : Thyristor
26
Capacitor Banks - M
Product Advantages:
• Easy montage / maintenance thanks to its modular design
• Withstand 1,18 x Vn over voltage and 1,50 x In over current
thanks to VCB series capacitors.
• 5 compensation racks can be put into panel easily thanks to
its efficient cooling system. Its power level can be raised up to
500 kVAr.
• Protection against touching.
Technical Specifications:
• Rated Voltage : 400 / 415 V*
• Nominal Frequency : 50/60 Hz M 30041
• Max. Power for 1 panel : 500 kVAr
• Up to 5 racks in one panel
• Standarts : EN 61439-1/2, EN 60831-1/2,
EN 60076-6, EN 60529, EN 60255-1,
EN 60947-4-1
27
Capacitor Banks with detuned harmonic filters - MS
Product Advantages:
• Easy installation / maintenance thanks to its modular design.
• Withstand 1,18 x Vn over voltage and 1,50 x In over current
thanks to VCB series capacitors.
• Compensation racks have harmonic filter reactor which
protects capacitors against to harmonics.
Technical Specifications:
• Rated Voltage : 400 / 415 V*
• Rated Frequency : 50/60 Hz
• Resonance Frequency : 189 Hz, 210 Hz, 215 Hz (and optional
other frequencies)
• Over Voltage : 520 V (24 hours / day)
• Standarts : EN 61439-1/2, EN 60831-1/2, EN MS 30044
60076-6, EN 60529, EN 60255-1,
EN 60947-4-1
Panel Dimensions:
28
Thyristor controlled capacitor banks with detuned filters
Product Advantages:
• Easy installation / maintenance thanks to its modular design.
• Withstand 1,18 x Vn over voltage and 1,50 x In over current
thanks to Asset VCB series capacitors.
• MST series capacitor banks uses thyristor to switch and so it
provides static switching continuosly.
Technical Specifications:
• Rated Voltage : 400 / 415 V*
• Rated Frequency : 50/60 Hz
• Over Voltage : 520 V (24 hours / day)
• Over Current : 1.5 In MST 50044
• Standarts : EN 61439-1/2, EN 60831-1/2, EN
60076-6, EN 60529, EN 60255-1,
EN 60947-4-1
Panel Dimensions:
29
MV Capacitor Banks - MLC
Open type MV capacitor banks are used for power factor correction,
voltage support, harmonic suppression and to maximize network
capacity in industrial applications and distribution systems.
Medium voltage capacitor banks are built up from medium
voltage, all-film dielectric capacitor units with separate internal
fuses for each element. The impregnation liquid is both non-PCB
and non-chlorine. Galvanized steel enclosures are available for
indoor and outdoor installations. Design and testing complies with
the requirements of the latest edition of relevant standards and
the specific technical requirements set by the customers.
Technical Features:
• Modular, compact and robust design optimized for easy
future expansion of the system, facilitating transport, storage
and installation.
• Galvanized steel or aluminum open type construction which
is available for indoor and outdoor installations.
• Design and testing complies with the requirements of the
latest edition of relevant standards and the specific technical
requirements set by the customers.
• Use of simplified design and proven components ensures high
reliability and low maintenance costs.
• Optimized to give a low environmental load by using recycled
materials.
• The banks are supplied as fully assembled units, factory tested
and ready for connection. MLC
500K/7,2
30
Static Electronic Switches - Thymod
Product Advantages:
• Ultra-rapid power factor compensation
• Zero crossing technology
• Transient free switching
• Silent capacitor switching
• No need to wait for discharge time before re-switching
• Unlimited number of switching operations
• Modular and compact standardized design
• Easy to install and replace Thymod
• Long life
• Power steps up to 100 kVAr
• Direct connection up to 480 V
Technical Specifications:
• Rated Voltages : 400 / 415 V* 2 Phase Control Connection Schema
• Max. Operation Voltage : 480 V AC
• Rated Frequency : 50 / 60 Hz
• Rated Current : Up to 160 A
• Response time : <40 ms
• Degree of protection : IP 20
• Operation Temperature : -10 oC / + 55 oC
• Type Of Semiconductor : Thyristor – Thyristor Module
• Mass : 6100 g
• Dimensions (WxDxL) : 125 x 225 x 240 mm
• Mounting : Vertical Mounting to mounting base
• Standards : EN 60429-1 , IEC 60439-1, IEC 60439-2
Product Portfolio
Model Connection Maximum step power at 400V
Type nominal busbar voltage
Thymod-25400-3P2 2 phase 25 kVAr
Thymod-50400-3P2 2 phase 50 kVAr
Thymod-100400-3P2 2 phase 100 kVAr
Thymod-25400-3P3 3 phase 25 kVAr
Thymod-50400-3P3 3 phase 50 kVAr
Thymod-100400-3P6 3 phase 100 kVAr
31
MV Products
Metal Enclosed Switchgear - SME ........................................................................................................................ 34
Metal Clad Switchgears - SNC .............................................................................................................................. 36
Metal Clad Switchgears - SMC .............................................................................................................................. 38
Rotary Disconnectors - SRS................................................................................................................................... 40
Earthing Switches - SES......................................................................................................................................... 41
Neutral Grounding Resistors - SRG........................................................................................................................ 42
Load Banks - SRL................................................................................................................................................... 43
32
D
MV Products
Energy
Industry
Building
33
Metal Enclosed Switchgear - SME
Product Advantages:
• LSC-2A loss of service continuity
• PI partition class
• AFL internal arc classification
• 3 separated and earthed accessible compartments
• Internal arc test up to 25 kA/1s
• Electrical and mechanical safety interlocks systems do not
allow to operational faults
• Optional withdrawable circuit breaker allows fast and easy
servicing
• Air insulated rotary switch option
• Reliable design and low maintenance cost
• 2 mm sheet steel
Technical Features:
SME
• Rated Voltage : 3,6... 40,5 kV
• Power Frequency Withstand Voltage : 10... 85 kV
• Lightning Impulse Withstand Voltage : 40... 185 kV
• Rated Frequency : 50 / 60 Hz
• Rated Current : 630... 1250 A
• Short Time Withstand Current : 16… 25 kA (1 s)
• Internal Arc Withstand Current : 16… 25 kA (1 s)
• Protection Class : IP3x / 2x
(Doors are closed / Between Compartment) Applications:
Metal Enclosed Switchgears are especially used in the transformer
centers, distribution systems, renewable energy production and
industrial plants where the rated current up to 1250 A and short
circuit current up to 25 kA.
• Energy Distribution Centers
• Hydroelectric and Wind Energy Applications
• Diesel and Natural Gas Power Plants
• Transformer Substations
• Cement Factories
• Auto Industry
• Petroleum and Chemical Industry
• Iron and Steel Industry
• Rolling Mills
• Pipe lines
• Shipyards
• Emergency Situation and Stand-by Power Facilities
• Mining
• Railway Substations
Dimensions
Model Description KDD Type Current Dimensions (mm) (W x D x H)
(Max) (Max) 12 kV 24 kV 36 kV
LBS 630 A 375 500 750
/0 Air Insulated Metal Enclosed 25 kA/1s SF6 GB 900 2000 900 1000 2000 1000 1400 2250
Switchgear, Front Access
SME Measure 1250 A 750 1000 1150
Air Insulated Metal Enclosed LBS 630 A 375 500 750
/1 Switchgear withdrawable Circuit 25 A/1s SF6 GB 900 2000 900 1000 2000 1000 1400 2250
Breaker, Front Access Measure 1250 A 750 1000 1150
34
Metal Enclosed Switchgear - SME
Technical Specifications
Description SME-1 3,6 SME-1 7,2 SME-1 12 SME-1 17,5 SME-1 24 SME-1 36 SME-1 40,5
Rated Voltage kV 3,6 7,2 12 17,5 24 36 40,5
Rated Insulation Voltage kV 3,6 7,2 12 17,5 24 36 40,5
Rated Power frequency withstand voltage kV 10 20 28 38 50 70 85
Rated Lightining impulse withstand voltage kV 40 60 75 95 125 170 185
Switchgears insulation Air
Circuit breaker insulation SF6 Gas
Loss of service continuity LSC-2A
Partition class PI
Internal Arc classification AFL
Rated frequency Hz 50/60
Rated short time withstand current kA 16/25
Short time withstand duration 5 1
Internal Arc withstand current kA 16/25
Internal Arc withstand duration 5 1
Rated main busbar current A 630 - 1250
Rated feeder current A 200 - 1250
Protection Class (When doors are closed) IP3X
Protection Class (Between compartments) IP2X
Color RAL 9003
Standards complied IEC 62271 - 200
35
Metal Clad Switchgears - SNC
Product Advantages:
• LSC 2B Loss of Service continuity
• PM Partition Class
• AFLR internal arc classification
• 4 or 5 separated and earthed accessible compartments
• Internal arc test up to 40 kA
• Electrical and mechanical safety interlocks
• Quick and easy service with withdrawable Vacuum / SF6 CB
• Quick and easy service with withdrawable voltage transformer
(Optional)
• 3 mm sheet steel
Technical Features:
SNC
• Rated Voltage : 3,6... 24 kV
• Power Frequency Withstand Voltage : 10... 50 kV
• Lighting Impulse Withstand Voltage : 40... 125 kV
• Rated Frequency : 50 / 60 Hz
• Rated Current : 630... 2500 A
• Short Circuit Withstand Current : 16... 40 kA (3 s)
• Internal Arc Current : 16... 40 kA (1 s)
• Protection Class : IP4x / 2x
Applications:
• Energy Transmission and Distribution Centers
• Hydroelectric Power Plants
• Diesel and Natural Gas Power Plants
• Transformer Substations
• Cement Factories
• Automotive Industry
• Chemical Industry
• Iron and Steel Industry
• Rolling Mills
• Pipelines
• Electro Chemical Facilities
• Shipyards
• Emergency Situation and Stand-by Power Plants
• Mining Industry
• Railway Substations
• Oil and Gas Industry
Dimensions
Model Insulation LSC Description SCC Type Current Dimensions (mm) (W x D x H)
(Max) (Max) 12 kV 24 kV 36 kV
25 kA 1250 A 650 800 --- --- ---
Withdrawable / 3s 2500 A 1000
1750 2565
1000
1 Air 2B CB Vacuum 31,5 kA VCB 1250 A 650 1400 2450
insulated / 3s 1250 A 800
Front Access 40 kA 2500 A 1000 --- --- --- --- --- ---
/ 3s 3150 A (*) 1000 2000
SNC Both 25 kA 1250 A 650 800
withdrawable / 3s 1750 2565 --- --- ---
2500 A 1000 1000
2 Air 2B VT & CB 31,5 kA VCB 1250 A 650 1750 2450
Vacuum / 3s 1250 A 800
insulated 40 kA 2500 A 1000 --- --- --- --- --- ---
Rear Access / 3s 3150 A (*) 1000 2000
(*) Please ask for detailed information.
36
Metal Clad Switchgears - SNC
SNC Series Metal Clad Switchgear
Technical Characteristics
Description SNC 3,6 SNC 7,2 SNC 12 SNC 17,5 SNC 24
Rated voltage kV 3,6 7,2 12 17,5 24
Rated insulation voltage kV 3,6 7,2 12 17,5 24
Rated power frequency withstand voltage kV 10 20 28 38 50
Rated lightning impulse withstand voltage kV 40 60 75 95 125
Switchgear insulation Air
Circuit breaker insulation Vacuum / SF6 Gas
Loss of service continuity 2B
Partition class PM
Internal arc classification AFLR
Rated frequency Hz 50/60
Rated short time withstand current kA 16/25/31,5/40
Short time withstand duration s 3
Internal arc withstand current kA 16/25/31,5/40
Internal arc withstand duration s 3
Rated main busbar current A 630 - 2500
Rated Feeder Current A 200 - 2500
Protection Class ( When doors are closed) IP4X
Protection Class ( between compartments) IP2X
Colour RAL 9003
Standards Complied IEC 62271—200
37
Metal Clad Switchgears - SMC
Product Advantages:
• LSC 2B Loss of Service continuity
• PM Partition Class
• AFLR internal arc classification
• 4/5 separated and earthed accessible compartments
• Internal arc test up to 31,5 kA/3s
• Electrical and mechanical safety interlocks systems do not
allow to operational faults SMC
• High level safety and energy continuity
• Quick and easy service with withdrawable Vacuum / SF6 CB
• Reliable design and low maintenance cost
• 3 mm sheet steel
Technical Features:
• Rated Voltage: 3,6... 40,5 kV
• Power Frequency Withstand Voltage: 10... 85 kV
• Lighting Impulse Withstand Voltage: 40... 185 kV
• Rated Frequency: 50 / 60 Hz
• Rated Current: 630... 4000 A
• Short Circuit Withstand Current: 16... 31,5 kA (3 s)
• Internal Arc Current: 16... 31,5 kA (1 s)
• Protection Class: IP4x / 2x (Doors are closed / Application Areas
Between Compartment) • Energy Transmission and Distribution Centers
• Hydroelectric Power Plants
• Diesel and Natural Gas Power Plants
• Transformer Substations
• Cement Factories
• Auto Industry
• Petroleum and Chemical Industry
• Iron and Steel Industry
• Rolling Mills
• Pipelines
• Electro Chemical Facilities
• Shipyards
• Emergency Situation and Stand-by Power Plants
• Mines
• Railway Substations
Dimensions
Model Insulation LSC Description SCC Type Current Dimensions (mm) (W x D x H)
(Max) (Max) 12 kV 24 kV 36 kV
Witdrawable 1600 A 800 1750 2100 1000 2000 2100 1200 3000 2300
CB on VCB 2500 A 1000 2000 1100
SMC 1 Air 2B truck Vacuum 31.5 kA 4000 A --- --- --- --- --- --- 3550 2550
insulated /3s SF6 1600 A 2000 2100 1400
CB 2500 A
1100 1100 2350 2250 3000 2300
Rear Access 2350 2250
3150 A
38
Metal Clad Switchgears - SMC
39
Rotary Disconnectors - SRS
Technical Features:
• Rated Voltage : 3,6... 36 kV
• Power Frequency Withstand Voltage : 10... 70 kV SRS
• Lighting Impulse withstand Voltage : 40... 170 kV
• Rated Frequency : 50 / 60 Hz
• Rated Current : 630... 1250 A
• Short Circuit withstand Current : 16… 25 kA (1 s)
• Intenal Arc Current : 16… 25 kA (1 s)
• Mechanical Endırance : 1.000 Operation Cycle
Technical Specifications
Product Code Product Type Ur (kV) Ir (A) Ik (kA) tk (s) Ud (kV) Up (kV) Ip (kA)
115.42.651.ND01-1 SRS-12/630-1601 12 630 16 40
115.42.651.NF01-1 SRS-12/630-2501 12 630 25 12 87 5 63
115.42.651.RD01-1 SRS-12/1250-1601 12 1250 16 40
115.42.651.RF01-1 SRS-12/1250-2501 12 1250 25 63
115.44.651.ND01-1 SRS-24/630-1601 24 630 16 40
115.44.651.NF01-1 SRS-24/630-2501 24 630 25 63
15 0 125
115.44.651.RD01-1 SRS-24/1250-1601 24 1250 16 40
115.44.651.RF01-1 SRS-24/1250-2501 24 1250 25 63
115.45.651.ND01-1 SRS-36/630-1601 36 630 16 40
115.45.651.NF01-1 SRS-36/630-2501 36 630 25 17 0 170 63
115.45.651.RD01-1 SRS-36/1250-1601 36 1250 16 40
115.45.651.RF01-1 SRS-36/1250-2501 36 1250 25 63
40
Earthing Switches - SES
SES series earthing switches are used for earthing the medium
voltage systems in safety.
SES series earthing switches can operate with all type of
disconnector mechanisim. Due to the air insulated type,
disconnector contact position can be observed easly.
SES series earthing switches are manufactured according to class
E2-B to have 5 times making capacity.
SES series earthing switches are manufactured according to IEC
62271-102 stamdard.
Technical Features:
• Rated Voltage : 3,6... 36 kV
• Power Frequency Withstand Voltage : 10... 70 kV
• Lighting Impulse Withstand Voltage : 40... 170 kV
• Rated Frequency : 50 / 60 Hz SES
• Short Circuit Withstand Current : 16… 40 kA
• Rated Short Circuit Withstand Time : 1s and 3s
• Mechanical Endurance : E2-B
Technical Specifications
Product Code Product Type Ur (kV) Ik (kA) tk (s) Ud (kV) Up (kV) Ip (kA)
115.42.758.0D01-1 SES-12/0000-1601 12 16 40
115.42.758.0E01-1 SES-12/0000-2001 12 20 50
115.42.758.0F01-1 SES-12/0000-2501 12 25 3 28 75 63
115.42.758.0H01-1 SES-12/0000-3101 12 31,5 80
115.44.758.0J01-1 SES-12/0000-4001 12 40 100
115.44.758.0D01-1 SES-24/0000-1601 24 16 40
115.44.758.0E01-1 SES-24/0000-2001 24 20 50
115.44.758.0F01-1 SES-24/0000-2501 24 25 3 50 125 63
115.45.758.0H01-1 SES-24/0000-3101 24 31,5 80
115.45.758.0J01-1 SES-24/0000-4001 24 40 100
115.45.758.0D01-1 SES-36/0000-1601 36 16 40
115.45.758.0E01-1 SES-36/0000-2001 36 20 50
3 70 170
115.45.758.0F01 -1 SES-36/0000-2501 36 25 63
115.45.758.0H01-1 SES-36/0000-3101 36 31,5 80
41
Neutral Grounding Resistors - SRG
Short circuits between phase and ground cause high fault currents
that results irreversible damages in the systems and Networks.
Neutral grounding resistors avert these damages by limiting the
fault current.
Neutral grounding resistors are used in industry by connecting to
the star points of the generators or transformers.
Grounding through a resistor has several advantages with respect
to other methods (such as insulated grounding, direct grounding
or grounding through a reactance). These advantages are easier
detection of fault location, limitation of fault current and no
transient over current.
SRG series neutral grounding resistors are used in substations,
hydroelectrical power plants, wind power plants.
SRG
Product Advantages:
• Quick and easier detection of fault location
• Limitaion the fault currents
• Protection agaginst transient voltage
• Large product range from low voltga level to high voltage level
• Design quality
• Design and production in complience with standards
Technical Features:
• Rated Voltage
• Fault Current
• Fault Duration
SRG
42
Load Banks - SRL
Product Advantages:
• Generators and UPS’ can be tested in safe
• Diesel motors are protected against to open circuit operation
• Provides proper load step by PLC
• Design quality
• Design and production in complience with standards
SRL
Essential information needed to design a Load Bank is:
• Rated voltage,
• Phases,
• Power,
• Number and type of steps, if any
• Type of ventilation (natural or forced)
43
MV Substations
Compact Substations made by Steel Sheet - SCK ................................................................................................. 46
Compact Substations made by Concrete - SMK .................................................................................................... 47
Compact Solar Substations - RST........................................................................................................................... 48
Mobile Substations - SMS..................................................................................................................................... 49
44
E
MV Substations
Energy
Industry
Building
45
Compact Substations made by Steel Sheet - SCK
Product Advantages:
• Internal arc classification in compliance with IAC A and B
• IP23D protection class
• Galvanized steel sheet construction, hot-dip galvanized steel
frame, electrostatic powder coat and NPU base profiles
• Optional HVAC, fire detecting and extinguisher system
• Suitable design for each type LV and MV panels.
Technical Features:
• Altitude : 1000 m
• Ambient temperature : -5 ... +50 °C SCK-1
• Pollution degree : Class 3
• Maximum Solar Radiation : 1000 W/m2
• Earthquake Resistance : 0,5 g horizontal and vertical
• Inner wall thickness : 1 mm Galvanized steel sheet
• Outer wall thickness : 2 mm Galvanized steel sheet
• Frame thickness : 3 mm Hot-dip Galvanized
steel sheet
• Wall Thickness : 40 mm
• Insulation material : EPS (Expanded Polystyren Foam)
• Insulation density : 1,8 kg/mᶟ
• Incombustibility degree :E
• R Value :7
Product Advantages:
• Internal arc classification in compliance with IAC A and B
• Protection class from IP23D up to IP54
• Suitable insulation material to ambient conditions
• NPU or NPI base profiles made by hot-dip galvanized against
corrosion
• Doors can be opened 120° outside and designed against to 20
J mechanical shock
• Rubber floor covering at level of 50kV and has A1
incombustibility degree
• HVAC, fire detecting and extinguisher system
• Special design and production to application
Technical Features:
• Altitude : 1000 m
SCK-2 • Ambient Temperature : -25 ... +50 °C
• Earthquake Resistance : 0,5 g horizontal and 0,4 g vertical
• Ur : max 40,5kV
• Fr : 50/60 Hz
• IAC : A and B
• IP : up to IP54
• Hazerdous Area : Zone2
46
Compact Substations made by Concrete - SMK
Product Advantages:
• Modular design
• Operation in safety
• Easy transport and start up
• Long service life
• High strength due to C35 concrete SMK
• Internal arc classification in compliance with IAC A and B
• Safety and tested earthing circuits
• Different product solutions to special projects
• Suitable design for each type LV and MV panels.
Technical Features:
• Altitude : 1000 m
• Ambient temperature : -5 ... +50 °C
• Pollution degree : Class 3
• Maximum solar radiation : 1000 W/m2
• Earthquake Resistance : 0,5 g horizontal and vertical
• IAC : A and B
• IP : IP23D
• Cl : 10
• Compressive strength class : C35
SPK series prefabricated concrete kiosks are transformer and
distribution substations manufactured up to 2500 kVA transformer
power.
SPK series prefabricated concrete kiosks are manufactured in
compliance with type tests received from international accredited
laboratories, IEC 62271-202 standards and TEDAŞ MYD standards.
Product Advantages:
• Easy assembly and disassembly on site
• High strength due to C35 concrete
• Internal arc classification in compliance with IAC A and B
• Safety and tested earthing circuits
• Suitable depth dimensions for installment metal clad
switchgear
• Different product solutions to special projects
• Manufacturing in compliance with internal arc test received
from accredited laboratories
• Suitable design for each type LV and MV panels.
Technical Features:
47
Compact Solar Substations - RST
The RST Line Compact Station represents a unique plug & play
solution already assembled and tested in the factory. It is ready to
be transported and installed on-site, connected through the string
boxes to the PV panels, then connected to the grid.
General Characteristics:
RECon RST-30H
• Power steps for H; 374, 561, 748, 935 and 1122 kWp.
• Power steps for H1; 416, 624, 832, 1040, 1248, 1664, 2080
and 2496 kWp.
• According to grid rated voltage. RECon RST
RECon RST-2.30H
• Power steps for H; 374, 748, 1122, 1496, 1870 and 2244 kWp.
• Power steps for H1; 416, 832, 1248, 1664, 2080 and 2496 kWp.
• According to grid rated voltage.
Product Advantages:
• More Than Sixty Years Experience in Manufacturing.
• High Maximum (99,3%) and Euro (98,7%) Efficiency Values.
• High Efficiency Thanks to The Climate Control System (< 30⁰C).
• Supplier to End User Unique Plug & Play Solution.
• Reduced The Costs of Engineering,
Transportation and On-Site Installation.
• Compact Design for Easy Maintenance and Service.
RST 30H1
48
Mobile Substations - SMS
Product Advantages:
• Mobile design
• Operation in safety
• Easy and quick transport and installment
• Special design solutions for different applications
• Diffferent applications on trailer, platform, wagon, vessel
• Quick solution for emergency power or additional power
requests
Technical Features:
• SMS 1 : 3.6 – 40.5 kV / 0.23 - 0.69 kV, 50/60 Hz, 0.5 - 4 MVA
• SMS 2 : 3.6 – 40.5 kV / 1 - 24 kV, 50/60 Hz, 1 – 31.5 MVA
• SMS 3 : 52 - 245 kV / 3.6 - 10.5 kV, 50/60 Hz, 1 - 45 MVA
SMS series
49
Power Converters
Modular Type Solar Inverters....................................................................................................................................... 52
String Boxes.................................................................................................................................................................. 53
50
F
Power Converters
Energy
Industry
Building
Medical Plants
Traction
51
Modular Type Solar Inverters
Product Advantages:
• More Than Sixty Years Experience in Manufacturing,
• High Maximum and Euro Efficiency Values,
• Parallel Modules or Independent Modules Configurations,
• Easy Maintenance Thanks to Withdrawable Power Section,
• Event Recording, Load Profile and Oscyllograph,
• Touchscreen Panel for Easy Access to Parameters,
• USB, Second Serial RS485, RS232 and Ethernet Ports.
General Characteristics
RECon 30L
• Power steps for 30L; 100, 200, 300, 400, 500 and 600 kW.
• Power steps for 30L1; 125, 250, 375, 500, 625 and 750 kW.
• Rated output voltage; 200 VAC for 30L, 250 VAC for 30L1.
RECon 2.30H-1 1227
RECon 30H
• Power steps for 30H; 150, 300, 450, 600, 750 and 900 kW.
• Power steps for 30H1; 167, 334, 501, 668, 835 and 1002 kW.
• Rated output voltage; 300 VAC for 30H, 330 VAC for 30H1.
RECon 2.30
• Power steps for 2.30H; 300, 600 and 900 kW.
• Power steps for 2.30H1; 334, 668 and 1002 kW.
• Rated output voltage; 300 VAC for 2.30H, 330 VAC for 2.30H1.
The Central Inverters are the first born and represent the flagship
of RECon Line. The line has been developed following FRIEM’s
traditional concepts of reliability, efficiency and modularity,
devoted to high flexibility and easy maintenance.
Our RECon Central Inverters have modular and compact design;
they can be used as single unit or combined in parallel to reach
the requested power. From one single module up to six modules,
starting from 100kWp up to 1470kWp, with 100% independent
operation of each module.
Thanks to the modularity, each Inverter can manage more than one
independent subfield with different irradiation and exposition,
with multiple MPPTs (up to 6 MPPTs for MW A.C.).
Fully automated Regulation performing, Control and Protection,
highest conversion efficiency, Standard Modbus-RTU
communication protocols and a touch screen operator panel, are
definitively value added features. With 20 years life design, and
industrial design suitable for hard environments, FRIEM’s Inverters
ensure easy maintenance and quick replacement of the main
components, granting the possibility of easy onsite maintenance
and simplified spare parts management.
The complete Removable Inverter Board can be replaced in only 1
hour, ensuring full reliability and continuity of production. All the
different models of the RECon Line have been tested and certified
according to IEC Standards and CE Directive, UL and CEC.
52
String Boxes
General Characteristics:
●● Number of Current Inputs : 8 – 12 – 16 – 18 – 36
●● DC Maximum Voltage : 1000 Vcc
●● DC Maximum Output Current : 128 – 384 Acc
●● Short Circuit Maximum Current : 192 – 512 Acc
●● DC Fuses (positive pole) : 12 – 15 Acc / 1 kVcc
●● DC Fuses (negative pole) : 12 – 15 Acc / 1 kVcc (Optional)
●● Withdrawable Fuse Holder : Var
●● AUX Power Supply : 230 Vac +/- +10
Models:
●● STR-n : String Box with n Current Input (Base Model)
●● STR-n .F : String Box with n Current Input + Fuses On Both Poles STR String Box
●● STR-n.D : String Box with n Current Input + Diodes
●● STR-n.C : String Box with n Current Input + Fast-On Connectors
●● STR-n .BI : String Box with n Current Input + Shunt Release
●● STR-n.BV : String Box with n Current Input + U/V Release
●● STR-n.A : String Box with n Current Input + Self Powered
●● STR-n.S : String Box with n Current Input Without Measurement
n= Number of inputs string box 8, 12, 16, 18 veya 36.
Not: All the options can be combined when ordered.
53
Traction Power Distribution
Traction Rectifiers. . .................................................................................................................................... 56
DC Circuit Breaker Cubicles........................................................................................................................ 57
Disconnecting Cubicles.............................................................................................................................. 58
Track-side and Depot Disconnecting Cubicles............................................................................................. 58
Negative Voltage Limiting Devices. . ............................................................................................................ 59
54
G
Traction Power
Distribution
Energy
Industry
Building
Traction
Solar Systems
55
Traction Rectifiers
Air cooled Diode Rectifiers are designed for Train Lines, Metro
Lines and Tram Lines. The range is completed with a complete
line of inverters and bidirectional converters, using thyristor, IGBT
or GTO, to comply with the recent requests of braking energy
recovery. Traction converters are fully comply with IEC or ANSI/
IEEE standards and the most severe standards for heavy traction
service. Low losses, low operating temperatures, reduced
maintenance and noise are granted by the specific design of the
power section.
Product Advantages:
• High Efficiency thanks to the reduced losses
• Short circuit high withstand capacity thanks to the
Robust Structure
• Production continuity and long operation life achieved with the
low operating temperature
• Reliability and reduced maintenance
Operating Characteristics:
T-RECT
• Connection : Bridge - Double Bridge (Series or Parallel)
• Type : Diode, Thyristor, IGBT
• Cooling : Natural Air, Forced Air, Water-to-Air
• DC Output Voltage : Up to 3300V
• DC Output Current : Up to 5000A
• Pulses : 6, 12
• Standards : IEC 60146 - ANSI/IEE
Power Section
• Exclusive aluminium extruded Busbars
• High efficiency and High Dynamic Stress Withstand
• Non-Magnetic Material Rectifier Cubicle
• Metal enclosed fixed or withdrawable Power Section
• Interphase Reactor for 12 Pulses Double Bridge in Parallel
Control Section
• High Accuracy Current Metering Systems by CTs or Shunts
• High Accurancy DC Voltage Metering System by voltage
transducer
• Automatic control combined with PLC and electronic boards
• Serial Communication for interface with DCS (Modbus, Profibus
DP, Ethernet, FMS or Datahighway Plus protocols)
• Alarm and trip messages history
• Temperature monitoring system
• DC Reverse Current monitoring system
• Earth Fault monitoring system
• Transformer control
56
DC Circuit Breaker Cubicles
57
Disconnecting Cubicles
Technical Features:
• Rated Voltage : 750 - 1500 - 3000 Vdc
• Rated Insulation Voltage : 4.8 kV
• Rated Impulse Withstand Voltage : 48 kV
• Rated Current : 1250 - 1800 - 3400 A
• Rated short-circuit Current (0,25s) : 50 kA
58
Negative Voltage Limiting Devices
For the security reason, the negative panels has an earthing position
visible from outdoor and lockable for negative maintanence at the
Substations or at lines of the Traction applications.
Negative Panels are consisting of earthing disconnector,
transducers and the measuring instruments.
Negative panel are integrated with over current relays and some
applications with over voltage relays where the Negative panels
includes OVPD.
Technical Properties:
• Rated Voltage : 750 - 1500 - 3000 Vdc
• Making Capacity : 35 - 50 - 100 kA
• Rated Insulation voltage : 4.8 kV
• Rated Impulse Voltage : 40 kV
• Insulation Class : IP30
LBR-n
OVPD
59
White…
Color of the beginning…
White, color of the purity, honesty and clarity…
Bayraktar Blv. Şehit sk. No: 5 Aktif Plaza Akşemsettin Mh. Çatalca sk. No:113
34775 Ümraniye İstanbul - Türkiye 06930 Sincan Ankara - Türkiye
Tel : +90 (216) 314 93 20 Tel : +90 (312) 269 46 02
Fax : +90 (216) 314 93 60 Fax : +90 (312) 269 45 01
www.aktif.net - amdt@aktif.net www.aktif.net - aet@aktif.net