Professional Documents
Culture Documents
Features/Benefits
A 13
AMP-TRAP 2000®
Dimensions
A 14
AMP-TRAP 2000®
A
Melting Time – Current Data, 600V Fuses
Current in Amperes
Time in Seconds
Features/Benefits
➤ Time delay for control transformer inrush loads without
nuisance opening
➤ Highly current limiting for low peak let-thru current
➤ Rejection-style design prevents replacement errors
(when used with recommended fuse blocks)
➤ High-visibility orange label ensures instant recognition,
and simplifies replacement
➤ Metal-embossed date and catalog number
for traceability and lasting identification
➤ Fiberglass body provides dimensional stability in harsh
industrial settings
➤ High-grade silica filler ensures fast arc quenching and
high current limitation
A 16
AMP-TRAP 2000®
A 17
AMP-TRAP 2000®
Peak Let-Thru Current Data–ATQR1/4 to 30, 600 Volts AC Melting Time-Current Data ATQR 3/16 to 1-8/10, 600 Volts
Maximum Instantaneous Peak Let-Thru Amperes
Time in Seconds
Current in Amperes
Available Current in RMS Symmetrical Amperes
Current in Amperes
A 18
AMP-TRAP®
AG CLASS G
Features / Benefits
AMPERE A B C
Standard Fuse Ampere Ratings, RATING In. mm In. mm In. mm
Catalog Numbers
1/2-15A 1.31 33.3 .406 10.3 .28 7.1
AMPERE CATALOG AMPERE CATALOG
RATING NUMBER RATING NUMBER 20A 1.41 35.8 .406 10.3 .28 7.1
4 AG4 40 AG40
5 AG5 45 AG45
6 AG6 50 AG50
8 AG8 60 AG60
10 AG10
B 31
AMP-TRAP®
Current in Amperes
Time in Seconds
AG15 to 60
Melting Time – Current Data, 480V Fuses
Current in Amperes
Time in Seconds
Maximum Instantaneous Peak Let-Thru Amperes
B 32
AMP-TRAP®
ATMR CLASS CC
Features / Benefits
➤ Rejection style design prevents replacement errors
when used with recommended fuse blocks
➤ Versatile design for individual component and
branch circuit protection
B 33
AMP-TRAP®
Refer to the Class CC Fuse Block section of this catalog for other details.
ATMR1/10 to 30
Melting Time – Current Data, 600V Fuses
Current in Amperes
Time in Seconds
Current in Amperes
B 34
AMP-TRAP®
Melting Time – Current Data 1/10 - 3-1/2 Amperes, 500 Volts AC Melting Time – Current Data 4 - 30 Amperes, 500 Volts AC
Time in Seconds
Time in Seconds
C2
AMP-TRAP®
C
HIGHLIGHTS: APPLICATIONS: Ratings Approvals
➤ Ferraz Electronics Inc.
➤ Fast Acting ➤ Supplemental protection ➤ AC: 1/4 to 3A
of 600V (up to 3A) and 600VAC, 10kA I.R.; Certified
500V (3-2/10-15A) 3-2/10 to 15A
AC circuits 500VAC, 10kA I.R.
➤ Small motors,
transformers, and Melting Time – Current Data 1/4 - 3 Amperes, 600 Volts AC
control circuits 3-2/10 - 15 Amperes, 500 Volts AC
Current in Amperes
C3
AMP-TRAP®
Current in Amperes
C4
TRI-ONIC®
Melting Time – Current Data 1/10 - 3-1/2 Amperes, 250 Volts AC Melting Time – Current Data 4 - 30 Amperes, 250 Volts AC
Time in Seconds
Time in Seconds
20 OTM20
25 OTM25
30 OTM30
Current in Amperes
C8
GGU 1-1/2" X 13/32" MIDGET FUSES
C9
GFN 1-1/2" X 13/32" MIDGET FUSES
Current in Amperes
C 10
SBS 1-3/8" X 13/32" FERRULE FUSES
Cross Reference: SBS will replace Bussmann BBS, Littelfuse BLS fuses
Time in Seconds
C 12