Hull No.:.......................................................................................5280, 5281 Classification society:..............................................................................LRS Pressure gauge calibration:..................................................................kg/cm2 Thermometer calibration:...........................................................................°C Language for signs:...................................................................................UK
2 Dimensions for boiler unit
Height excl. mountings:..................................................................7,350 mm
Diameter incl. insulation:................................................................3,050 mm Total height incl. retraction of burner lance:.................................11,000 mm Weight of boiler unit excl. water:....................................................28,800 kg Weight of boiler unit incl. water:....................................................39,700 kg
Working pressure:..........................................................................7/9 kg/cm2 Max. allowable working pressure:...............................................11.5 kg/cm2 Working temperature:..........................................................169.61/179.04°C Feed water operation:...................................................................modulating Feed water temperature, operation:...................................................85-95°C Feed water temperature, layout:..............................................................60°C
4 Combustion process data
Min. calorific value of diesel oil:................................................42,200 kJ/kg
Min./max. viscosity of diesel oil:.........................................2-12 cSt at 50°C Density of diesel oil:.......................................................................820 kg/m3
Language UK Page 1/4
TECHNICAL DATA FOR BOILER UNIT 735475,-77#01.0
Min. calorific value of fuel oil:...................................................40,200 kJ/kg
Max. viscosity of fuel oil:......................................................600 cSt at 50°C Density of fuel oil:..........................................................................990 kg/m3 Fuel oil temperature before pre-heater:...................................................55°C Fuel oil viscosity at burner inlet:...........................................................15 cSt Fuel oil temperature at burner inlet:......................................................130°C Ambient air temperature:........................................................................45°C Air excess No. at 100% load:...................................................................1.15 Flue gas temperature (clean boiler):.....................................................365°C Air consumption at 100% load:....................................................28,885 kg/h Flue gas flow (approx.):...............................................................30,747 kg/h Pressure loss:...............................................................................251 mmWC Expected back pressure from stack at full load:............................15 mmWC
5 Data for atomising steam
Atomising steam pressure at burner, max.:....................................6.5 kg/cm2
Atomising steam consumption, max.:..........................................95-120 kg/h Atomising air pressure at burner, max.:.........................................6.5 kg/cm2 Atomising air consumption, max.:....................................................170 kg/h
6 Data for electric systems
Power supply:......................................................................3 x 440 V, 60 Hz
Control voltage:...................................................................1 x 220 V, 60 Hz Pilot voltage:...........................................................................................24 V Insulation class:....................................................................................B or F Degree of protection:...............................................................................IP44 Colour of local control panel:.....................................Munsell no. 7.5BG 8/4 Colour of power panel:...............................................Munsell no. 7.5BG 8/4
Model:.................................................................................................AQ-18 Test pressure:...............................................................................16.5 kg/cm2 Protection of boiler body:....................................................75 mm insulation
Language UK Page 2/4
TECHNICAL DATA FOR BOILER UNIT 735475,-77#01.0
Colour of insulation plates:..........................................galvanized steel sheet
Model:.........................................................................................KBSD 1900 Burner capacity on diesel oil, min./max.:................................179/1,750 kg/h Burner capacity on fuel oil, min./max.:...................................179/1,860 kg/h Colour of burner....................................................................makers standard
9 Data for water level operation
Too high water level alarm:.............................................................+135 mm
High water level warning:...............................................................+110 mm Normal water level:...............................................................................0 mm Start stand-by feed water pump:................................mm/barg/not AI supply Low water level warning:.................................................................-120 mm Too low water level alarm and burner off:.......................................-145 mm Too low water level alarm and burner off:.......................................-145 mm
Safety valve:................................................................................11.5 kg/cm2 High steam pressure alarm and burner off (high):........................11.2 kg/cm2 High steam pressure alarm and burner off (low):...........................9.5 kg/cm2 High steam pressure warning:......................................................10.8 kg/cm2 High steam pressure warning:........................................................9.0 kg/cm2 Steam dump open:........................................................................8.5 kg/cm2 Burner start/stop (high):.........................................................9.2/10.5 kg/cm2 Burner start/stop (low):............................................................7.2/8.2 kg/cm2 Burner operation (high):................................................................9.0 kg/cm2 Burner operation (low):.................................................................7.0 kg/cm2 Low steam pressure warning:........................................................4.5 kg/cm2
Language UK Page 3/4
TECHNICAL DATA FOR BOILER UNIT 735475,-77#01.0
11 Manuals
Language for manuals:..............................................................................UK
Set of working manuals:.............................................................................15 Set of instruction manuals:...........................................................................4 Document revision date:................................................................JAN. 2001