You are on page 1of 2

PATENT PENDING

4th Generation
UniDirectional Captive Displacement Prover
Flow Management Devices’ 4th Generation
Unidirectional Captive Displacement Prover raises the bar for Small Volume Provers

4th Generation Prover Upgrades Include:


• Decreased overall weight and redesigned piston and poppet assembly allows for minimal flow disturbance
• Increased run-up time provides better accuracy for proving manufactured pulse meters
• All stainless steel drive system
• 4th Gen PIM with upgraded features

Decreased Weight Improved Serviceability & Safety Advantages of FMD Provers:

Observation windows added as a safety feature • Uncertainty:


to allow visual access to the drive end. - Typically exceeds 0.005%
• Repeatability:
- ISO Cal Lab exceeds 0.02%
• Conforms to API 4.2 and API 4.6
• Easily handles heavy crude
• All wetted parts stainless/PTFE
Longer seal life, fewer parts and less • Galvanized frame per
weight allows for ease of servicing. ASTM A123/123M-02
The newly designed drive end reduces
mass by close to 40%. • Smooth belt drive with clutch
• Metric detector bar option
Less Flow Disturbance
• Shock mounted isolation pads for
independent drive and support
Seal changes are simplified by readily • 3 point installation for secure
accessible piston and poppet. mounting on uneven surfaces
*Davit arm option available
• 2” connections allow for rapid
draining (FMD025 to 245)
• 2” vents for pressure and temp
verification (FMD025 to 245)
• Prover validation /self-test function
The redesign of the piston and poppet • Four year warranty
assembly increases measurement volume
while providing smoother operation.

+1.602.233.9885 - E: sales@flowmd.com - www.flowmd.com


FMD 4th
F L O Generation
W M A N A G E MProver - Model Information
ENT DEVICES, LLC
5225 South 37th St, Suite 4, Phoenix AZ 85040 • Phone (602) 233-9885 • Fax (602) 233-9887 • Website: www.FlowMD.com

4TH GENERATION PROVER CONFIGURATION


NOT ALL CONFIGURATIONS SHOWN ON THIS TABLE ARE AVAILABLE – CONSULT FACTORY

A B C D D D (E E) F G H I J K L M N O O O O
Prover Type [A]
H = Horizontal Special Options [O...] Consult factory
V = Vertical Leave blank if none

Structural Components [B]


Seal Material [N]
4 = 304, & galvanized frame
E = Ekonal
6 = 316 & galvanized frame
C = Carbon
8 = 316 & stainless frame
(Note: Can contain other materials.)

Tube Finish [M]


Wetted Components [C] W = Wrap (Standard)
4 = 304 N = Natural Finish
6 = 316 P = Painted (To customer specification. If none
supplied, it will be painted per FMD paint specification)
**Consult factory prior to selecting ‘P’ option
Max Flow Rate [DDD]
001 = 100gpm (142BPH) [23m3/hr] Motor Voltage [L]
003 = 300gpm (428BPH) [68m3/hr] A = 24 VDC (001-060)
007 = 700gpm (1,000BPH) [150m3/hr] B = 110-120 VAC 1ph (001-090)
015 = 1,500gpm (2,100BPH) [330m3/hr] C = 220/230/240 VAC 1 phase (001-090)
025= 2,500gpm (3,570BPH) [560m3/hr] D = 190/208-230/240 VAC 3 Phase (*)
035 = 3,500gpm (5,000BPH) [790m3/hr] F = 380/400/415 VAC 3 Phase (*)
A35 = 3,500gpm (5,000BPH) [790m3/hr] I = 440/460/480 VAC 3 Phase (*)
045= 4,500gpm (6,500BPH) [1,022m3/hr] M = Hydraulic
060 = 6,000gpm (8,500BPH) [1,350m3/hr] *Please note Delta or Wye configuration on 3 phase
090 = 9,000gpm (12,850BPH) [2,000m3/hr]
130 = 13,000gpm (18,500BPH) [2,900m3/hr]
Frequency [K]
200 = 20,000gpm (28,500BPH) [4,500m3/hr]
A = DC
245 = 24,500gpm (35,000BPH) [5,565m3/hr]
B = 50 Hz
C = 60 Hz
Flange Configuration [(EE)]
(RR) = Right in - Right out
(RL) = Right in - Left out Pressure Class [F] Flange Type [G] Pressure Rating [H] Covers Type [I] Area Classification [J]
(RT) = Right in - Top out 1 = ANSI A = Raised Face PER ASME B16.5(B16.5M) TABLE 2-1.1 S = Standard (Quick Access) E = US/CSA Class 1 Div 1 40°C
-20 TO 100°F (-29 TO 38°C)
(4A) = 4 Flange 2 = PED B = Ring Joint P = Purge ( ≤ -20°F Product) G = US/CSA Class 1 Div 2 40°C
A = 150# = 285PSI (19.6BAR)
(LL) = Left in - Left out J = ATEX Ex d mb [ia] IIB T3 Gb -20° to 40°C
B = 300# = 740PSI (51.1BAR)
(LR) = Left in - Right out K = IECEx Ex d mb [ia] IIB T3 Gb -20° to 40°C
C = 600# = 1480PSI (102.1BAR)
(LT) = Left in - Top out D = 900# = 2220PSI (153.2BAR)
(TT) = Top in – Top out E = 1500# = 3705PSI (255.3BAR)
(TR) = Top in – Right out

NON_CONTROLED DOCUMENT

*Please contact FMD to verify prover sizing. Meter type, process fluid and operating conditions must be considered to properly size a prover.
**Please note: Standard prover volume is in gallons, litres are optional ***Displaced litre value is not a direct conversion from gallon values. Prover
requires non-standard switchbar for litres. Columns highlighted in gray denotes 3rd Generation design.

Contact Us Today to Discuss your Proving Application

5225 South 37th Street, Suite 4 - Phoenix, AZ 85040 -1.602.233.9885 - sales@flowmd.com - www.flowmd.com
FMD-UCDP 4th Generation Data Sheet 1.24.1 08-19 Copyright 2019 - All rights reserved

You might also like