You are on page 1of 2

ST-1 1

STARTING - STARTER
ST084-04

REPLACEMENT
1. REPLACE BRUSHES
HINT:
Only the 2 brushes of the positive (+) side (York side) are ex-
Cut
changeable, negative (-) side brush must be changed in the
York Side body with the brush holder.
Terminal York Side (a) Cut the brush lead wire at the terminal side.
Served Part Terminal (b) Shave welded mark of the brush lead wire with sandpaper
Served Part Z07247
etc., and correct the terminal to the specified.

NOTICE:
Width Thickness Part to be shaved is so narrow that you should take care not
to harm the field coil.
Specified width: 5.0 mm (0.197 in.)
Specified thickness: 1.6 mm (0.063 in.)

Z07248

(c) Press the plate of the supply brush on the welded side of
the terminal lead wire.
Brush
Weld Side

Z07249

(d) Solder the pressed part, and shave to the specified mea-
sures with the sandpaper etc.
Specified width: 7.0 mm (0.276 in.)
3.3 mm Specified thickness: 3.3 mm (0.130 in.)
 Heat the soldered part well, and fiow the solder in-
side the plate, take care not to flow it into flow it into
the inside lead wire.
7 mm  Take care not to flow the solder into field.
Z07250

2. REPLACE CENTER BEARING


(a) Using SST and press, press out the center bearing.
SST
SST 09221-25026 (09221-00090)

Z03208

2002 ECHO (RM884U)

Author: Date: 839


ST-12
STARTING - STARTER

(b) Using SST and a press in a new center bearing to the


position shown in the illustration.
SST 09221-25026 (09221-00090)
SST

ST0670

2002 ECHO (RM884U)

Author: Date: 840