You are on page 1of 12

Which optional, licensed HPE B-Series SAN switch capability enables each switch to monitor a variety

of SAN fabric elements for potential faults and automatically alerts the network administrator of
problems before they become failures?

SAN Network Advisor

Advanced Performance Monitor

Fabric Watch

Fabric Vision

Which 12- or 24-port Fibre Channel switch from HPE is designed and recommended for use in hyper-
scale, private cloud storage, and highly virtualized environments, and supports the “pay-as-you-grow”
model?

HPE StoreFabric SN6000B switch

HPE StoreFabric 8/24 switch

HPE StoreFabric SN6500B switch

HPE StoreFabric SN3000B switch

Which HPE C-Series enterprise package license feature enables selective transfer of data traffic
between specific initiators and targets on different virtual SANs without merging them into a single
logical fabric?

Extended VSAN Fabric (EVF)

Inter-VSAN Routing (IVR)

Adaptive Networking (AN)

Enhanced Group Management (EGM)


Which statements correctly describe the HPE SN6000 Fibre Channel Switch? (Select two.)

Its single-power models are upgradable to dual power.

It starts as a 24-port switch and is expandable to 48 ports within a single switch device.

It requires the Enterprise Fabric Management Suite (EFMS) software.

It comes in a 1U form factor.

It has four (4) dedicated stacking links.

Which HPE-supported switches are designed to fit into the interconnect bays of the HPE BladeSystem
c-Class enclosure? (Select two.)

HPE Encryption SAN Switch

Brocade 16Gb SAN Switch

HPE 8/20q Fibre Channel Switch

Cisco MDS 9222i Multiservice Modular Fabric Switch

HPE 6Gb SAS Switch

You need to reset your HPE B-Series SAN switch to the HPE default settings. What must you do?

Use the configDownload command with a downloaded HPE default configuration file.

Download the latest firmware file from HPE and use the firmwareDownload command.

Use the configDefault command to reset the SAN switch configuration.

Call the HPE support center and obtain a specific set of instructions from the support personnel.

What is the out-of-the-factory default username and password for the HPE B-Series SAN switches?

username = hpe, password = hpe

username = admin, password = password

username = admin, password = <blank>

username = <blank>, password = administrator


Review the picture below.

Which SAN tool is represented by this picture?

Web Tools

Intelligent Infrastructure Analyzer software

SANXpert

SANtelligence
You installed Web Tools to manage basic zoning and traffic isolation zoning in your SAN environment.
Now, you want to perform advanced tasks such as clone operations for zoning. Which type of license
must you install on the 8Gb or 16Gb HPE B-Series SAN switches?

Power Pack + license

SAN Enterprise license

APM license

EGM license

Which statement is true about the basic (free-of-charge) management capabilities of the HPE B-Series
SAN Network Advisor?

It can manage up to 10 FOS fabrics.

It can manage up to 300 switch ports.

It provides QoS, ingress rate limits, and traffic isolation zones.

It supports B-series DC SAN Backbone Director and SN8000B 8-Slot SAN Director devices.

What automates multi-switch configuration operations across enabled Brocade SAN switches to save
time and streamline repetitive operations?

QoS zoning

APM

LSAN zoning

EGM

What is the default zoning setting of the HPE C-Series SAN switches?

local access

all access

peer access

no access
Which zoning statements are correct? (Select three.)

Devices may belong to only one zone.

If a device is not a member of a zone, it is not accessible by any device within that zone.

The number of zones and zone members are limited by the sum of switch ports in the fabric.

Devices may be members of more than one zone.

Zoning provides security.

Which Fabric OS zoning enforcement validates only the ELS frames that were used to establish a
session?

session-based software enforcement

domain-based zone enforcement

frame-based hardware enforcement

session-based hardware enforcement

You need to completely reset the zoning configuration definitions on your Brocade B-Series SAN
switches. Which other commands must be used in conjunction with the cfgClear command to save the
cleared SDRAM into flash and clear everything on the switch? (Select two.)

cfgDisable

cfgReset

cfgDelete

cfgCreate

cfgSave

cfgPurge
What happens when you merge two fabrics, where one fabric is zoned and the other fabric is unzoned
but set to “no access?”

The fabrics merge cleanly.

The fabrics end up segmenting.

The fabrics merge, but no access is given.

The zoned fabric’s configuration propagates to the unzoned fabric.

What is the purpose of traffic isolation zoning?

It allows SAN design and management to be done at the port granularity.

It allows devices on separate Fibre Channel fabrics to communicate with each other.

It provides selective device connectivity between fabrics without merging them.

It allows control of traffic flow between switches using dedicated paths.

Review the picture below.

Which SAN fabric concept do the dashed circles in this picture represent?
Virtual Fabrics

LSAN zoning

FC-FC routing

traffic isolation zoning

Review the picture below.

You are configuring an HPE 3PAR Smart SAN. Your configuration consists of:

a single 48-port switch

40 initiators

4 target ports

4 groups of 10 initiators associated with each target port

How many zones do you need to create for target-based zoning?

48

40

16
Which statements correctly describe the HPE 3PAR Smart SAN? (Select two.)

It requires a Smart SAN agent to be installed on the SAN hosts.

It requires HPE H-Series SAN switches with the Enterprise Fabric Management Suite software.

Its management and orchestration is enabled via out-of-band metadata collection.

It requires a Smart SAN license to be installed on the 3PAR StoreServ array.

It is embedded in the 3PAR OS.

Match each Fibre Channel routing term with its correct definition. (Drag each item in the right column
to the corresponding item in the left column. Let the cursor hover over an item to see its full text.)
virtual fabric
a chain of switches -
from a source switch-
...
path
a collection of port-
s from a set of conn-
...
route
a dynamically assign-
ed path that a devic-
...
hop
a point-to-point lin-
k (an interswitch li-
nk)

Which term refers to transmitting multiplexed traffic from several devices across a single ISL for the
reasons of optimizing the switch utilization?

thin provisioning

oversubscription

storage convergence

auto-provisioning

undersubscription
Which HPE B-Series SAN switch command enables or disables trunking on all ports in the switch?

switchport trunk enable | disable

portCfgTrunkport

trunkEnable | trunkDisable

switchCfgTrunk

What must you do to successfully configure ICLs in a fabric that consists of HPE SN8000B 8-Slot SAN
Backbone Director switches?

You must install the ICL optical cables before installing the enterprise ICL licenses.

You must be running Fabric OS 5.0.1 or later.

You must have two unused ports in each Director switch.

You must install an enterprise ICL license on each Director switch.

If trunking is not enabled on a C-Series port channel, how many VSANs can use this port channel?

none

one

two

four

What is true of adaptive trunking and stacking with the HPE H-Series switches?

Stacking supports up to 8 switches per stack.

Stacking on the HPE SN6000 switch requires two unused 2Gb/4Gb/8Gb switch ports.

Adaptive trunking balances frames across multiple paths between two or more switches.

Adaptive trunking does not require a license.


Which statements correctly describe the creation and management of logical switches? (Select two.)

The default logical switch is assigned Fabric ID of 255.

When the virtual fabrics feature is enabled, a default logical switch is created, containing all switch
ports.

When the virtual fabrics feature is enabled, ISLs are no longer supported.

The default logical switch can only be deleted if you disable the virtual fabrics feature.

Which statements correctly describe the creation and operation of VSANs on HPE C-Series SAN
switches? (Select two.)

When a port is removed from a VSAN, it is moved to the default VSAN0.

Each HPE C-Series SAN switch supports 128 VSANs.

By default, all switch ports belong to the default VSAN0.

Traffic disruptions are isolated and have no impact on other VSANs.

Each VSAN has its own fabric services, which cannot communicate by default with devices in other
VSANs.

Which statements correctly describe a routed fabric and routed fabric services? (Select two.)

A router in a Meta SAN provides any-to-any connectivity between fabrics.

Each fabric maintains a unique fabric services configuration.

Routing connects devices in multiple fabrics without extending fabric services from one routed fabric to
another.

A disruption of fabric services in one routed fabric typically affects the entire Meta SAN.
What do HPE B-Series Virtual Fabrics use to share devices across logical fabrics? (Select two.)

inter-fabric routing (IFR)

fabric shortest path first (FSPF)

inter-VSAN routing (IVR)

intelligent resilient forwarding (IRF)

inter-fabric links (IFLs)

Which optional, licensed HPE C-Series SAN switch feature enables you to configure devices in one
VSAN to access devices in another VSAN?

FSPF

IFR

IRF

IVR

What would enable you to implement transparent routing to a remote fabric containing C-Series
devices?

DC Director switch

1606 Extension SAN switch

H-Series switch

MPX200 multi-function router

You are troubleshooting connectivity issues within an HPE B-Series SAN fabric. What in the
portErrShow output indicates that the problem is likely caused by a bad or damaged cable or a faulty
device in the path?

increasing number of class 3 frames being discarded (disc 3)

increasing number of encoding errors outside of frames (enc_out)

non-zero value for loss of synchronization (loss sync)

non-zero value for loss of signal (loss sig)


Where do you obtain the Boot PROM recovery password for the HPE B-Series SAN switches?

from the toe-tag shipped with every switch

from the output of the switchCfg command

from the output of the recover password menu option

from the switch support provider

You are troubleshooting an HPE 3PAR Smart SAN installation. What does the portcfgshow <port
number> command, issued from the HPE B-Series SAN switch, enable you to determine?

whether the target driven peer zoning is enabled

whether the peer zones are recognized by the fabric

whether the SAN switch is running a supported version of the FOS

what the FDMI database contents are

You might also like