High-Voltage

Circuit Breakers
From 72.5 kV up to 1100 kV

Siemens Energy is a trademark licensed by Siemens AG.


High-Voltage Circuit Breakers | iPDF Chapter overview

Customized products with


the shortest delivery times
from our global production
network
03 Foreword
04 Modular design

05 Control
06 Monitoring
07 Interruption principles

08 Drive system

09 Development and routine testing 11 Live tank circuit breakers 15 Dead Tank Compact

10 Installation and commissioning 13 Dead tank circuit breakers 16 Disconnecting Circuit Breaker
High-Voltage Circuit Breakers | iPDF Chapter overview

Live tank circuit breakers Dead tank circuit breakers Compact switchgear Disconnecting Circuit Breaker

Circuit breakers from Siemens Energy


The availability of electric energy is vital for economic development and For more than 150 years we have been shaping and improving the
for quality of life and the demand is constantly increasing. One of the energy world. More than 200,000 circuit breakers delivered to 150
necessary conditions for a reliable electric power supply is a well-func- countries prove this.
tioning transmission system.
3AV1 FG Blue 145 kV Siemens Energy worldwide supports customers along the entire Sustainability is the core of our actions
chain of energy conversion, with an efficient range of products,
solutions and know-how for the transmission of electrical energy Siemens Energy is fully committed to supporting worldwide agreements
from one source. and sustainable development goals of nations and our customers. Our
ambition is to achieve climate-neutrality in our own operations by 2030
Circuit breakers are the central part of air-insulated (AIS) and gas-insu- and to cover 100% of our own electricity consumption from renewable
lated (GIS) switchgear. High-voltage circuit breakers are mechanical sources by 2023. Furthermore, we want to make power grids completely
switching devices which connect and break current circuits (operating free of greenhouse gas emissions with highest performance and health
currents and fault currents) and carry the nominal current in closed and safety standards. Sustainable means for us: zero SF6 gas, zero F-mix-
position. gases and zero greenhouse gases. Our Blue products with vacuum
interruption and clean air insulation combine the game changing
As a world market leader, Siemens Energy takes the responsibility to technology paving the way for climate neutral high-voltage switchgear.
provide circuit breakers which meet highest environmental, technologi-
cal and economic conditions in the various countries worldwide. read more ...
3AP4 FI 800 kV pole
High-Voltage Circuit Breakers | iPDF Chapter overview

Basic components Type designation

Modular design
Few basic components leading to a high
diversity of types

High-voltage circuit breakers from are identical and based on decades of


Siemens Energy, regardless of type or manufacturing and operating experi- 3AP1 FG up to 245 kV 3AP1 FI up to 300 kV 3AP2 FI up to 550 kV
voltage range, are designed in a well ence. Our GIS switchgear range also
proven modular platform concept. This includes the same interrupter units,
leads to a high diversity of circuit breaker operating mechanisms and control
types and to high flexibility with regard to elements. By applying this proven
various applications according to our modular design not only at our lead
customers’ requirements. factory in Germany, but also within
our global manufacturing network,
The main components, such as we are able to fulfill the highest
• operating mechanism, expectations regarding availability
• control system, and reliability at eminently competi-
• base frame, tive prices. 3AP1 DT up to 362 kV 3AP1 DTC up to 245 kV 3AP2/3 DT up to 550 kV
• kinematic chain and
• insulator designs This modular principle can also be All construction types consist of the same basic components:
• current transformers (DT / DTC) found in the type definition of our
• pre-insertion resistors (PIR) high-voltage circuit breakers. 1.  Interrupter unit 3. Pillar 5. Operating mechanism cubicle
2.  Post insulator 4.  Control cabinet 6. Closing resistor
High-Voltage Circuit Breakers | iPDF Chapter overview

Control

The control system includes the second- • Local actuator


ary technical components required for
operating the circuit breaker, which are Compact variant
mainly arranged in the control cabinet.
The control, tripping, motor and heating In addition to the basic variant, this
power supplies can be selected by the compact variant includes:
customer. Two standard control variants • Spring monitoring by motor run time
are available depending on your require- monitoring
ments. • Heating monitoring (current measuring
relay)
Basic variant • Light and socket attachment with a
common circuit breaker to facilitate
The basic variant includes all control and servicing and maintenance work
monitoring elements that are needed for • Overvoltage attenuation
operation of the circuit breaker, including • Motor circuit breaker
the following: • Heating circuit breaker
• Switching operation counter Special customer adapted solutions can
• 19 auxiliary switch contacts be offered on request.
(9 normally open, 9 normally closed, Cabinet with control and stored-energy spring drive mechanism
1 wiper contact)
High-Voltage Circuit Breakers | iPDF Chapter overview

Controlled switching Controlled contacts


SensgearTM EdgegearTM
with PSD with SICEA01

Circuit breaker monitoring


SensgearTM – Born connected Beneficial applications

While monitoring equipment can already • Preventive detection of suspicious &


provide a lot of information, the focus of critical assets thereby reducing the risk
SensgearTM is goes beyond common asset of unplanned outages
management, it supports active manage- • Early warning and push notification on
ment of the grid. With SensgearTM the mobile devices before it gets critical
gas-insulated switchgear or circuit • Reduced manhours on equipment with
breakers transmit their current status in less costs & time for travel and SF6
near-real time via an online application. controlling at site
This facilitates qualified decision-making • Cost savings for unplanned SF6 leakage
and optimized grid management, which repairs
which results in more flexibility and more • Less risk contingencies and penalties
economic operation and a reduction of for SF6 emissions
unplanned downtime. • Mechanical lifetime trending and
projection
Please contact your local sales or visit our • Fleet coverage in a unified manner
website for most recent information. • Artificial intelligence powered analysis
• Comprehensive visualization tools to
support further decision making
High-Voltage Circuit Breakers | iPDF Chapter overview

Vacuum interruption Self-compression Dynamic self-


Clean air insulation
principle principle compression principle

Interruption principles
Vacuum interruption principle • High performance, low arc energy, and
very low erosion during switching
Vacuum interrupters form the backbone operations, resulting in excellent
of our 3AV1 blue portfolio. Based on more interruption performance, e.g. in terms
than 40 years of experience in medium- of high numbers of current interrup-
voltage range and more than 6 million tions for rated and short-circuit
delivered vacuum interrupters, Siemens currents
Energy has introduced this proven tech- • No maintenance due to sealed for life
nology to high-voltage power networks in technology
2010. The technology is characterized by • No greenhouse gas usage or emissions
a number of distinctive features, such as
• High reliability due to the hermetically read more ...
tight vacuum interrupter
• No toxic materials or decomposition
products
• Perfect for low temperatures, no
liquefaction of switching medium

1.  Insulating envelope 3.  Movable contact


2.  Fixed contact 4. Bellow
High-Voltage Circuit Breakers | iPDF Chapter overview

Drive system
Stored-energy spring mechanism The mechanism types differ in terms of
the number, size and arrangement of the
1
The operating mechanism is a central part opening and closing springs. Both the
of high-voltage circuit breakers. The drive closing and opening springs are located
concept of the 3AP circuit breaker family inside the operating mechanism, thereby
is based on the patented stored-energy achieving a simple and sturdy device. This
spring principle and is identical on all design minimizes the number of required
types. The use of such an operating moving parts. The use of roller bearings
mechanism for voltage ranges of up to and of the maintenance-free charging
1100 kV became appropriate as a result mechanism is a prerequisite for reliable
of the development of a self-compression operation over decades. Proven design
interrupter unit that requires minimal principles such as vibration-isolated
actuating energy. The compact design latches and load-free isolation of the
of this operating mechanism makes it charging mechanism were retained.
possible to place the stored-energy spring
mechanism within the control cubicle read more ...
in a compact housing.
1. Switching rod 6. Connecting rod for closing spring
2. Trip coil CLOSE 7. Trip coil OPEN
3. Charging gear 8. Opening spring
4. Opening latch 9. Closing spring
5. Connecting rod for opening spring
High-Voltage Circuit Breakers | iPDF Chapter overview

Development and type testing Routine testing

Quality right from the start


Development and type testing All our circuit breakers are completely
type-tested in accordance with latest IEC,
The foundation of quality for Siemens ANSI and other standards before their
Energy circuit breakers begins right in market launch. In our lead factory in
the development of a new product. Berlin, we have one of the most modern
Switching performance, high voltage testing laboratories available which are
stability and performance under normal accredited according to IEC 17025, part of
mechanical loads (wind and short the European network of the indepen-
circuits) as well as seismic conditions are dent testing organization, PEHLA as well
simulated and optimized in the outline as member lab of the Short-Circuit
design phase using digital twins. The use Testing Liaison (STL).
of parts and assembly units in a large
number of breaker types such as live All required facilities are available:
tank, dead tank, as well as GIS leads to a
high volume standardization of the main • Basic research and vacuum switching
components. Steady and regular amounts laboratory
of produced units form a continuous • High-voltage testing laboratory
production process and ensure the highest • High-power testing laboratory
standards. Statistical quality control is • Mechanical testing laboratory
based on large numbers produced, and • Temperature rise testing laboratory
hence, a higher validity is achieved.
read more ...
High-Voltage Circuit Breakers | iPDF Chapter overview

Easy installation and


commissioning
Our circuit breakers for voltage ratings Lifelong service for the
from 72.5 kV to 300 kV can be transported circuit breaker
fully pre-assembled and routine-tested.
All higher ratings are dismantled into We provide installation, commissioning
compact, clear and space saving subas- and maintenance on request. And once
semblies for transportation purposes. installed, Siemens Energy circuit breakers
Transportation costs are minimized by will operate safely and reliably for years.
packing several circuit breakers together But in the unlikely event of a fault, you
in one shipment. The subassemblies can can rely on our worldwide customer
quickly be installed into a complete circuit support.
breaker at the substation. A single super-
visor can install one circuit breaker within We offer service attendance throughout
one and a half days. the entire operating life of the circuit
Due to the fact that the circuit breaker is breaker. Inspection, maintenance, repair
already routine-tested in the factory, and a round-the-clock fault service give
commissioning can be reduced to a you the necessary backup.
minimum and there is no need for special
tools or equipment.
read more ...
High-Voltage Circuit Breakers | iPDF Chapter overview

Gallery Portfolio Technical data

3AV1FG Blue live tank


circuit breaker
Vacuum technology is the game changer for F-gas-free high-
voltage power grids

The outstanding technical performance interruptions, 10,000 rated current interrup-


and low lifecycle costs of vacuum circuit tions, optional 2-cycle current interruption,
breakers make this solution the preferred full performance down to –60°C ambient
technology and led to a phase out of SF6 temperature, and maintenance-free inter-
in power networks up to 52 kV. The same rupter unit during its lifetime.
proven technology paved the way for
climate-neutral high-voltage applications Zero greenhouse gases:
of Siemens Energy since 2010.
• Greenhouse- and F-gas free insulation
The member of our Blue product family is • No CO2 emissions
designed according to our well proven
modular platform concept and meets the read more ...
same high quality standards as our SF6
portfolio. Moreover, it has a number of World’s first substation with SF₆-free switchgear technology from Siemens Energy in a
features superior to SF6 circuit breakers. 110 kV high-voltage grid (Noerdlingen, Germany 2018)
These include 30 full short-circuit current
High-Voltage Circuit Breakers | iPDF Chapter overview

Gallery Portfolio Technical data

3AP live tank circuit breaker

For applications from 72.5 kV up to 1100 kV

In contrast to dead tank circuit breakers, per pole and can also be delivered with
the interrupter unit in live tank breakers is closing resistors on request (3AP5).
not grounded during operation; it is ex-
posed to high-voltage potential and there- Moreover, our high-voltage live tank circuit
fore these circuit breakers are called live breakers are available for three-pole opera-
tanks. tion with a common base (FG), for single
The 3AP circuit breaker family is available pole operation also with a common base
for rated voltages from 72.5 kV up to (FE) or for one pole operation with separate
1100 kV. 3AP1 circuit breakers up to 300 kV bases (FI). In accordance with our modular
are equipped with one interrupter unit per design, all 3AP live tank beakers are
pole and 3AP2 circuit breakers up to 550 kV equipped with our stored-energy spring
include two interrupter units. For applica- drive mechanism and our self-compression
tions from 362 kV to 550 kV, the circuit interrupter units.
breakers can be equipped with optional
closing resistors (3AP3). For higher voltage read more ... 3AP1 FG 245 kV
levels, the 3AP4 includes 4 interrupter units
High-Voltage Circuit Breakers | iPDF Chapter overview

Gallery Portfolio Technical data

3AV1DT Blue dead tank


circuit breaker
Vacuum technology is the game changer for F-gas-free high-
voltage power grids

The outstanding technical performance gas or any other F-gas emissions and to
and low lifecycle costs of vacuum circuit achieve their goals on climate protection.
breakers make this solution the preferred The Blue dead tank breakers offer rated
technology and led to a phase out of SF6 in voltages up to 145 kV, a rated short-circuit
power networks up to 52 kV. The same breaking current of up to 63 kA and a rated
proven technology paved the way for current of up to 3,150 A, whilst providing
climate-neutral high-voltage applications easiest possible operating and recycling
of Siemens Energy since 2010. processes.
The brandnew member of our Blue portfo-
lio is the world’s first climate-neutral 123 kV read more ...
dead tank breaker, fully type tested accord-
ing to IEEE and ANSI standards and will be
installed at a pilot customer in California.
We are proud to be joining our customers
in taking the next steps toward sustainable 3AV1DT 145 kV
power transmission with no greenhouse
High-Voltage Circuit Breakers | iPDF Chapter overview

Gallery Portfolio Technical data

3AP dead tank circuit


breaker
For applications from 72.5 kV up to 550 kV

In contrast to live tank circuit breakers, • High short-circuit breaking currents


dead tanks have a metal-enclosed inter- possible (up to 90 kA with one inter-
rupter unit, and the housing is always rupter unit)
grounded. Therefore, they are called dead • Low center of gravity of the bases
tank circuit breakers. For certain substation (higher seismic withstand capability)
designs, dead tank circuit breakers might • Gas mixture or heating system for
be required instead of the standard live lowest temperature applications
tank breakers. The dead tank breaker offers • Gas-insulated components ensure
particular advantages if the protection highest availability with minimum
design requires the use of several current maintenance effort
transformers per pole assembly. • 362 kV and 550 kV available with
pre-insertion resistor (PIR) solution
Most important characteristics of a
dead tank breaker: read more ...
• Toroidal-core current transformers on 3AP1 DT 145 kV
bushings (compact construction)
High-Voltage Circuit Breakers | iPDF Chapter overview

Gallery Portfolio Technical data

3AP1 DTC Dead Tank


Compact
For 145 kV and 245 kV applications

The hybrid concept on which the 3AP1 breaker, fitted with one or two current
Dead Tank Compact (DTC) is based transformers, one or more disconnectors,
combines SF6-encapsulated components earthing switches and bushings as appli-
and air-insulated devices. The application cable for connection to the bus bar system.
of gas-insulated components increases
availability of the switchgear. According to And of course, based on our modular
CIGRE analyses, gas-insulated components design, the core components are adopted
are four times more reliable than air insu- from our high-voltage circuit breakers,
lated components. Furthermore, safety can disconnectors and GIS product family. Due
be enhanced by separating gas compart- to the compact design and the flexible use
ments, e.g. between the circuit breaker of predefined modules, different layouts
and disconnector. can be realized with a minimum of engi-
The DTC circuit breaker is a compact neering effort.
arrangement of several functions needed
in a substation. The elements of this read more ... 3AP1DTC 145 kV
compact switchgear is a dead tank circuit
High-Voltage Circuit Breakers | iPDF Chapter overview

Gallery Portfolio Technical data

3AP DCB Disconnecting


Circuit Breaker
For 145 kV and 420 kV applications

In switchgear, isolating distances in air The proper function of the kinematic chain
combined with circuit breakers are used to has been most thoroughly verified. The
protect the circuit state in the grid. closest attention was paid to developing a
Siemens Energy has developed a device in mechanical interlock which guarantees
which the isolating distance has been that the circuit breaker remains in the open
integrated in the SF6 gas compartment in position when used as a disconnector.
order to reduce external environmental
influences. The DCB (Disconnecting Circuit When this mechanical interlock is acti-
Breaker) is used as a circuit breaker and vated, it is impossible to close the breaker.
additionally as a disconnector – two func- The current status of the DCB can also be
tions combined in one device. monitored electrically and is shown by
The DCB was developed on the basis of a clearly visible position indicators.
higher-rated standard 3AP circuit breaker to
provide the higher dielectric properties read more ...
required. Due to the SF6-insulated discon- 3AP1DCB 145 kV
nector function there is no visible opening
distance anymore.
Published by

Siemens Energy Global GmbH & Co. KG


Transmission
Freyeslebenstraße 1
91058 Erlangen
Germany

For the U.S. published by


Siemens Energy, Inc
Transmission
4601 Six Forks Road
Raleigh, NC 27609
USA

For more information, please visit our website:



siemens-energy.com/circuit-breakers
or contact us: circuit-breakers@siemens-energy.com

© Siemens Energy, 2021

Siemens Energy is a trademark licensed by Siemens AG.

Subject to changes and errors. The information given in this


document only contains general descriptions and/or performance
features which may not always specifically reflect those described,
or which may undergo modification in the course of further
development of the products. The requested performance features
are binding only when they are expressly agreed upon in the
concluded contract. All product designations may be trademarks or
product names of Siemens Energy Global GmbH & Co. KG or other
companies whose use by third parties for their own purposes could
violate the rights of the owners.