MAQUET Datascope CS100 IABP

Specifications

• Automatically evaluates and selects optimal


trigger source and lead
• Sets inflation at the dicrotic notch and deflates
IAB at the start of systole
• Responds to changes in signal quality by
selecting new trigger source and re-timing to
adapt to patient rhythm changes

Note: The technical data given in this


publication is for general information and
are subject to change without notice.
Actual configuration on the unit may vary.
Contact our sales representatives for a
complete list of details.

Soma Technology Inc. • 166 Highland Park Drive • Bloomfield, CT 06002 • USA
Phone: 1.800.GET.SOMA • www.SomaTechnology.com • Email: soma@somatechnology.com
MAQUET Datascope CS100 IABP - Page 1 of 2 -

Color Display: 8.3”(21 cm)W x 6.2”(15.8cm)H; up 45°, down 55°, right 70°, left 70° viewing angle; Rotates 330°;
Tilts180°; Detachable; Laptop-like closure for storage and protection

Preferences Menu: User may select display sweep speed (25 or 50 mm/sec), brightness (low, med., high); balloon wave
form (on/off); ECG inflation markers (on/off); flashing alarms (on/off)

Operation Modes: Auto, Semi Auto, Manual

ECG Trigger: Threshold dynamically adjusted by system for high sensitivity and selectivity of the R-wave detection;
Minimum = 120μV ± 20μV at normal gain; 40μV at max. gain

Pressure Trigger: Default trigger threshold is automatically adjusted to 38% of the difference between peak systolic
and end diastolic (avg. over multiple cycles); In variable mode: User adjustable between 7 and 30
mmHg ± 3 mmHg

Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms

Pacer V/A-V Trigger: V Pacer: fixed at rate up to 185 bpm (no demand pacing) A-V Pacer: fixed at rate up to 125 bpm (no
demand pacing) with A-V intervals between 80-224 ms

Internal Trigger: Variable mode: 40-120 bpm; Normal mode: 80 ± 1 bpm

Tall T-Wave Rejection: Rejects all T-Waves where Q-T interval is <300 ms
(ECG and Pacer A mode) and the amplitude is <70% of QRS input amplitude

Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV (ECG


(ECG and Pacer A mode) and durations between 0.1 ms to 2.0 ms with: 1) No tail; 2) 100 ms time constant tail < 1 mV; 3)
25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV

ECG Leads: In Auto Operation Mode: I, II, III, External In Semi-Auto Mode: I, II, III, AVR, AVL, AVF, V, External (12 lead
compatibility)

ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)

Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)

Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to Monitor)

Defibrillator Protection: Discharge levels 􀀩360 J (trace returns to screen in 5 sec. max)

ESIS: Automatic suppression with internal ECG amplifier

AP Source Selection: Transducer/external (menu based)

AP Input Sensitivity: 5.0μV/V/mmHg

Excitation: +5 VDC ± 5% @ 130 mA (max)

Frequency Response: DC to 12 Hz (display)

External Mon. Inputs: ECG: 1 V/mV (nominal); AP: 1 V/100 mmHg (nominal)

ECG/BP Output: Phone Jack: ECG 1V / mV, BP 1V/100 mmHg

Soma Technology Inc.


166 Highland Park Drive
Bloomfield, CT 06002 • USA
1.800.438.7662
www.SomaTechnology.com

Note: The technical data given in this publication is for general information and is subject to change without notice. Actual configuration on the
unit may vary. Contact our sales representatives for a complete list of details.
MAQUET Datascope CS100 IABP - Page 2 of 2 -

Mains Voltage: 100-120 VAC ± 10% or 220-240 VAC ± 10%

Mains Frequency: 50/60 Hz ± 3 Hz

Internal Battery: 24 VDC (nominal), 17.2 Amp-hour, 3 hrs.(approx. @ 90 bpm)

Battery Type: Maintenance free; Sealed lead-acid

System Compressor: Dual head diaphragm pump with brushless DC motor

IAB Helium (He+): Medical-grade; 0.5 L (2900 psi) or 0.69 L (2200 psi)
He+ Endurance 1.8 mo. (.5 L); 2 mo. (0.69 L): continuous operation -(nominal): 24 hrs./day

Condensate Removal: Fully automatic condensate removal and disposal

WIN-IABP (optional): Software for remote clinical assistance and training

Service Diagnostics: Built-in software for system analysis and troubleshooting

Modem Data Rate: Up to 9,600 baud

Size on Cart: 45.2”H x 17.6”W x 23.4”D


(114.8 cm x 44.7 cm x 59.4 cm) max

Size off Cart: 28.2”H x 11.3”W x 21.5”D


(71.6 cm x 28.7 cm x 54.6 cm) max

Console Weight: 76.8 lbs. (34.8 Kg) nominal

Monitor: 9.5 lbs. (4.3 Kg) nominal

Hospital Cart Weight: 64.0 lbs. (29.1 Kg) nominal

Internal Battery: 34 lbs. (15.4 Kg) nominal

UTS Version: Rugged base which attaches to docking station (DS)

Dimensions: 30.0”H x 22.5”W x 13.2”D (76.2 cm x 57.2 cm x 33.5 cm)

Console Weight: 133.2 lbs. (60.4 Kg)

Lightweight DS*: 17.8” (45.1 cm) x 20.0” (50.8 cm)


*(Suggested Option)

Op. Temp.: 10°C - 40°C

Op. Humidity: 5 - 95% (R.H.) non-condensing

Op. Altitude: 0 - 12,000 feet (3,657 m); automatic altitude correction for

Soma Technology Inc.


166 Highland Park Drive
Bloomfield, CT 06002 • USA
1.800.438.7662
www.SomaTechnology.com

Note: The technical data given in this publication is for general information and is subject to change without notice. Actual configuration on the
unit may vary. Contact our sales representatives for a complete list of details.