Professional Documents
Culture Documents
5
Company: Page: 1
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 24/08/2020
E-Mail:
Specifiers comments:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.5.5
Company: Page: 2
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 24/08/2020
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.5.5
Company: Page: 3
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 24/08/2020
E-Mail:
Selected solution
Bar size Drill bit size Bar spacing - Y Bar spacing - X Distance Required drill
centre/centre centre/centre centre/surface hole
Ø [mm] D [mm] s [mm] s [mm] cs [mm] linst [mm]
Bar with highest 25.0 32.0 94.0 94.0 63.0 465
load
Required accessories
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.5.5
Company: Page: 4
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 24/08/2020
E-Mail:
Pullout bond strength fbd,po 6.25 N/mm² ETA 19/0601
Controlling bond strength fbd = max(fbd,pi/α2; min(fbd,spl; fbd,po)) 3.40 N/mm²
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.5.5
Company: Page: 5
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 24/08/2020
E-Mail:
Design Input
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.co.uk Hilti PROFIS Rebar 2.5.5
Company: Page: 6
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Date: 24/08/2020
E-Mail:
Remarks
This design exclusively considers the local load transfer from the post-installed tensile reinforcement at the intersection between new and
existing concrete. The joint surfaces for concreting must be roughened to at least such an extent that aggregates protrude. It assumes that
adequate transverse reinforcement is provided in the anchorage area if required.
The shear load carrying capacity of the cross section has to be designed separately.
The HIT Rebar Design is used in this calculation evaluates solely the strength of the connection; serviceability criteria are not considered.
Indications on displacements and creep of post-installed rebars can be found in the European Technical Approvals for anchors. The Installation
(drilling, cleaning, setting) must be according to the approval!
Fixed diameter and spacing selected. Please be aware that over-reinforcement of the section may lead to brittle failure of the fastening.
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be
followed to ensure a proper installation.
Minimum reinforcement requirements are not checked by the software.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Rebar ( c ) 2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan