The OIT (Operator Interface Terminal) is where all pump controls are input. Here you can start/stop the pump,
change pressure, check pump data, and view errors and warning messages.
• Active Alarms
• Start Pump
• Stop Pump
• Pressure Select
(Electronic pressure
control units only)
• Alarms
• Login Page
• Stroke Parameters
• Meters Main
• Counters Main
• Documentation
Service Manuals
The functions of the control buttons are described in the following sections.
H2O Jet • www.waterjetparts.com • PH. 360-866-7161 • Pump Training Manual • Section 7 1 (4)
PUMP TRAINING MANUAL
OPERATOR INTERFACE TERMINAL
Counters Main
The “COUNTERS” page list:
STROKE COUNT - The stroke count of the front and rear intensifiers can be logged when the “electronic shifting”
package is supplied.
OIL LEVEL LOW OCCUR – logs the number of times that the oil level has dropped below acceptable levels.
OIL OVER TEMP OCCUR – logs the number times that the oil temperature exceeds acceptable levels.
INLET WATER PSI LOW – logs the number of times the inlet water pressure falls below 30 psi [2.07 bar]
E-STOP COND OCCUR – logs the number of times the emergency stop button is activated.
OVERSTOKE OCCUR – logs the number of times the intensifier has shifted more times than allowed in a given interval.
BOOSTER OVER TEMP OCCUR – logs the number of times the booster pump temperature exceeds acceptable levels.
Meters Main
Maintains a record of the time the H2O Jet Pump unit, the hydraulic pump, booster pump, front and rear intensifiers
have run.
H2O Jet • www.waterjetparts.com • PH. 360-866-7161 • Pump Training Manual • Section 7 2 (4)
PUMP TRAINING MANUAL
OPERATOR INTERFACE TERMINAL
Alarms
The “ALARMS” page lists all the faults that are currently active. Pressing the “ALARM HISTORY” button will display
the time, date and description of every alarm since the history was last cleared.
Previous
This button sends you back to the main page.
Supervisor Menu
The supervisor Menu is accessible through the “Setup Page” on the main screen. Once logged in as a supervisor,
this allows the supervisor to reset the meters and counters. This is very useful in tracking “mean time” between
major repairs. The Supervisor Menu is password protected, the factory set user id is h2o and password is 321.
H2O Jet • www.waterjetparts.com • PH. 360-866-7161 • Pump Training Manual • Section 7 3 (4)
PUMP TRAINING MANUAL
OPERATOR INTERFACE TERMINAL
Sets the stroke parameters for the intensifier and provides information of failures/leakages within the system. Out of
stroke tolerance is how long the machine has to accomplish the expected number of strokes. Minimum Stroke Fault
Parameter is the number of strokes the machine must make within the “Bandwidth” amount of time. If the machine
does not meet these numbers it will shut down in an alarm condition and display the reason. Leaving the machine
running “deadhead” past the time limit will cause the Intensifier to shut down.
H2O Jet • www.waterjetparts.com • PH. 360-866-7161 • Pump Training Manual • Section 7 4 (4)