You are on page 1of 3

APPROVED WATER METERS

15mm to 20mm with pulse output

Flow Measurement Water Meters


At a glance:
Media: cold water Single Jet WRAS
Pressure range: 0 to 16 Bar max
Media temperature: 30°C Water Meter
BSP Union Fittings WRAS approval
MID approved for billing requirements

15mm (1/2")
Safe to use on potable drinking water
Nominal diameter: 15 - 20mm
15mm - 20mm
Mounting: Any position measures flow and
Height: 68.5mm, Length: 110 -
20mm (3/4") 130mm,
quantity
Diameter: 72 Meets MID
Maximum flow rate: 2 m³/h
WRAS Approved Pulse reader with reed switch and fly Requirements
lead. 0 - 16 Bar
MID Approved
TECHNICAL
Pulse Reader Flow Dimensions
Maximum Maximum
Nominal Pressure Pressure
Max Pressure 16 Bar DN Height Length Diameter
Diameter m³/h
Rating Loss (mm) (mm) (mm)
(mm) L D
(MPa) (kPa) H

15 15 1.6-2.5 1.6 100 68.5 110 72

20 20 2.5-4.0 1.6 100 68.5 130 72

PARAMETERS

Screwed Connection

GENERAL INFORMATION

For measuring the flow and volume of water with a temperature up to 30 °C on a maximum working
pressure up to 16 bar. Suitable for installation in horizontal pipelines with the counter directed upwards
and in vertical pipelines with the counter directed sidewards. Water meters in standard version are
equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing. Pulse
outputs of 1:1 and 1:10
Features and advantages include resistant to strong external magnetic field ¨ readings reliability, fulfils the
newest metrological requirements of MID ¨ easy reading of the water meter counter ¨ hermetic counter
(with increased tightness) resistant to steaming ¨ counter mechanism with blockade against multiple
rotating ¨ rotation angle more than 360° and protection against mechanical tampering ¨ Protection limiting
the results of water freezing ¨ Double-sided rotor bearing ¨ Outlet port of water meter housing suitable for
optional installation of a return valve.

Tel: 0330 1595933 enquiries@envirotechalarms.com


APPROVED WATER METERS
25mm to 40mm with pulse output

Flow Measurement Water Meters


At a glance:
Media: cold water
Pressure range: 0 to 16 Bar max
Single Jet WRAS
Media temperature: 30°C Water Meter
WRAS approval BSP Union Fittings
MID approved for billing requirements
Safe to use on potable drinking water
Nominal diameter: 25 - 40mm
25mm - 40mm 25mm (1")
Mounting: Horizontal/Vertical measures flow and
Height: 120mm, Length: 260 -
300mm quantity
Diameter: 25 - 40mm
30mm (1 1/4")
Maximum flow rate: 7.8 - 20 m³/h
Meets MID
Pulse reader with reed switch and fly Requirements
lead. 40mm (1 1/2")
0 - 16 Bar
WRAS Approved
TECHNICAL
MID Approved
Flow Dimensions
Maximum Maximum
Nominal Pressure Pressure Pulse Reader
DN Height Length Diameter
Diameter m³/h
Rating Loss (mm) (mm) (inches)
(mm) L D
(MPa) (kPa) H
Max Pressure 16 Bar
25 25 6.3 1.6 63 120 260 1 1/4

32 32 10 1.6 63 120 260 1 1/2

40 40 16 1.6 63 120 300 2

PARAMETERS

H
D

GENERAL INFORMATION

For measuring the flow and volume of water with a temperature up to 30 °C on a maximum working
pressure up to 16 bar. Suitable for installation in the horizontal pipelines with the counter directed upwards
and in vertical pipelines with the counter directed sidewards. Water meters in standard version are
equipped with low eight-barrel counter (IP65), antimagnetic protection SN +, brass housing. Pulse
outputs of 1:1 and 1:10
Features and advantages include resistant to strong external magnetic field ¨ readings reliability, fulfils
the newest metrological requirements of MID ¨ easy reading of the water meter counter ¨ hermetic
counter (with increased tightness) resistant to steaming ¨ counter mechanism with blockade against
multiple rotating ¨ rotation angle more than 360° and protection against mechanical tampering ¨
Protection limiting the results of water freezing ¨ Double-sided rotor bearing ¨ Outlet port of water meter
housing suitable for optional installation of a return valve.
APPROVED WATER METERS
40mm to 300mm with pulse output

Flow Measurement Water Meters


At a glance:
WRAS Approved
Media: Cold water
Pressure range: 0.3 to 16 Bar max Water Meter
PN16 Flanged Media temp: 30ºC max
WRAS Approved

40mm (1 1/2")
MID approved for billing requirements
Safe to use on potable drinking water
40mm - 300mm
Nominal diameter: 40 - 300mm
Mounting position: Any
Maximum flow rate: 31 - 2000 mᶟ/h measures flow of cold
50mm (2") Minimum flow rate: 0.25 - 16 mᶟ/h
Constant flow rate 25 - 1600 mᶟ/h
water up to 30 degrees
Pulse reader with reed switch and fly
65mm (2 1/2") lead.
0.3 - 16 Bar
80mm (3")
Specification
100mm (4")
Constant Maximum Dimensions
Working
Nominal Flow Pressure Pressure Height Length Diameter
150mm (6") DN Diameter
Rating Loss
(mm) (mm) (mm) (mm)
mᶟ/h (Bar) (Bar) H H H
200mm (8")
40 40 25 0.3 - 16 0.16 177 200 150
250mm (10") 50 50 40 0.3 - 16 0.16 187 200 165
65 65 63 0.3 - 16 0.16 197 200 185
300mm (12") 80 80 100 0.3 - 16 0.16 219 225 200
WRAS Approved 100 100 160 0.3 - 16 0.16 229 250 220
125 125 250 0.3 - 16 0.16 257 250 250
MID Approved 150 150 400 0.3 - 16 0.16 357 300 285
200 200 630 0.3 - 16 0.16 382 330 340
Pulse Reader
250 250 1000 0.3 - 16 0.16 427 450 400
300 300 1600 0.3 - 16 0.16 497 500 460

General Information
For measuring the flow of cold water with a temperature up to 30 °C. This is a Woltman’s type dry
water meter with a horizontal impeller axle parallel to the pipe axis. They are long lasting and
reliable for use in industrial measurements of water usage. These water meters are constructed
to be mounted on horizontal, vertical and inclined water supplies. Pulse outputs of 1:10 and 1:100

Features and advantages include resistance to external magnetic field ¨ wide measuring range ¨
low loss of pressure ¨ easy installation ¨ very good anti-corrosive qualities ¨ 2004/22/EC directive
standard ¨ PN-EN-14154:2005 rated ¨ OMIL R49:2004/2006 design for measuring cold drinking
water.

You might also like