You are on page 1of 4

Republic of the Philippines

Department of Education
Region III
Division of Bulacan
SHS Fortunato F. Halili National Agriculture School
Guyong, Sta. Maria, Bulacan

Name: ___________________________ Score: ___________________________


Grade/Specialization: EIM ___________ Date: ___________________________
Subject Teacher: ___________________ Mothers Signature: ________________

I. On your answer sheet, encircle the letter of your answer. (NO ERASURE)
1. A wire used for wiring electric ranges, hot water heaters, stoves and hairdryers where both heat and moisture resistance
is desirable.
a. Duralene (type WP)
b. Coaxial cable
c. Asbestos covered nickel cord (Rockbestos)
d. Steel tape armored power cable with ground wire (Copper)
2. A wire commonly used for wiring motorized engines and appliances with high temperature, and for switch board
wiring.
a. Temperature wire (type HI)
b. Thermoplastic wire (type TW)
c. Asbestos covered nickel cord (Rockbestos)
d. Coaxial cable
3. This is a multi-conductor cable generally used for interior wiring installations in dry and wet locations.
a. Durex wire
b. Nonmetallic sheathed cable (type NMC)
c. Asbestos covered nickel cord (Rockbestos)
d. Steel tape armored power cable with ground wire (Copper)
4. This wire or cable is used for radio frequency antenna installation, and radar transceiver installation.
a. Control cable
b. Royal cord
c. Duralene (type WP)
d. Coaxial cable
5. This wire or cable has 2, 3 or 4 conductors, stranded, and used for portable cords in electrical equipment.
a. Control cable
b. Royal cord
c. Intercom cable
d. Coaxial cable
6. This is polyethylene-insulated line wire used for wiring installation of residential buildings.
a. Intercom cable
b. Royal cord
c. Duralene (type WP)
d. Flat cord (type SPT)
7. This is the maximum ampacity of a 5.5 mm copper with type THHN insulation if the conductor is to be used in an with
ambient air temperature of 39°C.
a. 40 A
b. 36 A
c. 35 A
d. 34 A
8. This wire cannot be used in wet locations.
a. TW
b. THW
c. THHN
d. THWN
9. This is the maximum operating temperature of a THHN wire.
a. 60°C
b. 75°C
c. 85°C
d. 90°C
10. A copper conductor is to supply an air conditioning load which has a nameplate rating of 22 A. What size of THWN
wire is safe and economical?
a. 8.0mm
b. 2.0mm
c. 3.5mm
d. 5.5mm
11. A type of flexible armored cable with a rubber insulated conductors inside the armor.
a. type AC b. type ACT c. type ACL d. type ACV
12. A type of flexible armored cable that has varnish cambric insulation.
a. type AC b. type ACT c. type ACL d. type ACV
13. A type of flexible armored cable that has rubber insulation and a lead sheath between the conductor and the armor.
a. type AC b. type ACT c. type ACL d. type ACV
14. The appropriate tool used in cutting flexible armored cable.
A. pliers b. hacksaw c. backsaw d. knife
15. The free conductor inside the outlets or switch points for making up of joints or connections of fixtures or devices.
a. 100mm b. 120mm. c. 160 mm d. 180mm
16. PPE refers to
a. Personal Protective Equipnent.
b. Parsonal Protective Equipment.
c. Personal Protective Equipment.
d. Personal Protective Eqiupment.
17. Quarter bend is a 90 degree angle bend.
a. 180
b. 90
c. 70
d. 160
18. What is the right description for S4W?
a. Four-Way
b. Switch Four-Way
c. Way-Switch Four
d. Four –Way Switch
19. Used by linemen to remove insulation of wire and cables in low and high voltage transmission lines.
a. Utility knife
b. Hack saw
c. Wire Stripper
d. Cutter
20. A tool used for removing insulation of medium sized wires ranging from gauge #10 to gauge #16.
a. Wire Stripper
b. Conduits
c. Driver Hammer d. Portable Electric Drill

21. What is the purpose of turning the drill on before attempting to drill a hole ______________________.
a. sees if the drill operates.
b. sees if the drill bit is running true.
c. makes sure the chuck key has been removed.
d. check if the power cord is good

22. The purpose of moving the drill and the bit up and down often while drilling deep holes is to __________________.
a. ream the hole slightly larger.
b. gives the drill operator better drilling leverage.
c. help keep the hole centered.
d. reduces overheating in the drill bit.

23. What will likely happen if a large capacity portable drill bit jams during the drilling operation?
a. The bit will break.
b. The drill will rotate in the opposite direction to the bit causing injury to the user’s wrist.
c. The drill will likely stall out and overheat.
d. The hole will become badly distorted.

24. What kind of pressure should be applied to a drill during the drilling operation?
a. Light, even c. Moderate, even
b. Medium, even d. Heavy, even

25. What type of drill speed is needed for wood drilling operation?
a. Low c. Medium
b. Low-medium d. High

26. What type of drill speed is needed for most metal drilling operations?
a. Low c. Medium-high
b. Medium-low d. High

27. What is the purpose of a pilot hole when drilling?


a. to make the final hole drilling operation easier.
b. To guide the final drilling operation and achieve a more accurately place hole.
c. to reduce the feed pressure needed to drill a hole.
d. to allow the final hole to be drilled at a faster revolution per minute (rpm) and to finish smoothly.
28. What should the operator do to prevent seizing when drilling?
a. Reduce the rpm's of the portable electric drill
b. Lubricate the drill bit.
c. Use a high speed drill bit.
d. Reduce the feed pressure when the bit is about to finish drilling.
29. What personal protective equipment should be worn when operating the portable disc grinder?
a. Safety glasses
b. Safety glasses and hearing protection
c. Safety glasses, hearing protection and gloves
d. Safety glasses, hearing protection, gloves and respirator.
30. When operating the portable disc grinder, the grinding disk should be positioned so that the sparks and grit are thrown
_____.
a. away from the operator.
b. away from the operator and others in the work area.
c. up to avoid hitting others.
d. down to avoid hitting others.
31. Which of the following element of electric circuit serves as current consuming device? a) Control (switch) c) Path (wire
conductor) b) Source (battery) d) Load (lamp)
32. There are four possible conditions in electric circuit, which is considered the most dangerous because it might cause fire?
a) Short Circuit c) Grounded Circuit b) Closed Circuit d) Open Circuit

33. Suppose you want to check the continuity of the flat cord, what particular part of test light and continuity tester indicates the
condition of the cord?
a) Neon Lamp c) LED’S b) Toggle Switch d) Battery

34. A Water heater is one of the basic electric gadgets in this module, which is not an application of this gadget?
a) Cooling c) Cooking b) Heating d) Sterilizing

35. You encountered difficulties in driving screws in tight location which is the appropriate driving tools for the job? a)
Standard/ Flat Screw Driver
c) Allen Wrench
b) Stubby Screw Driver
d) Philip Screw Driver

II. A. Match the electrical symbols in Column A with the corresponding descriptions in column B. Write the letter of
your answer in the space provided before each number.

Column A Column B
_______1. S3w a. Service entrance (Three wires)

_______2. b. Three-way Switch

_______3. c. Fuse Cutout


_______4. d. Incandescent lamp

_______5. e. Convenience Outlet


f. Power Panel board
g. Crossed Wires Connected
B. Direction: Match the tools in column A with their classifications in column B. Write only the letter of the correct
answer in your answer sheet.
Tools Classification
_______ 1. screw driver A. drilling equipment
_______ 2. claw hammer B. cutting tool
_______ 3. Pliers C. measuring tool
_______ 4. wire gauge D. driving tool
_______ 5. power drill E. measuring and testing

III. A. Direction: On a separate sheet of paper, write T if the statement is correct and F if it is false.

_____ 1. All tools can be used as hammer.


_____ 2. Chisel is an example of boring tool.
_____ 3. Light tools and equipment should be placed at the lowest part of the
cabinet shelf.
_____ 4. Tooth cutting tools should be sharpened as often as necessary.
_____ 5. Tools and equipment must be stored according to their kind.

You might also like