siemens.com/energy/hvdcplus
An unparalleled challenge:
keeping your grid performing predictably
in times of unpredictable generation
2
Flexibility and power quality Maintaining the highest standards
In today’s power grids, flexibility and power An HVDC solution that improves your exist-
quality are in high demand. HVDC can ing grid infrastructure needs to address the
provide optimum solutions for your specific following aspects:
transmission tasks. This requires: • Maximum availability
• Efficient use of HVDC technology with any • Stabilization of the AC network
project-specific adapted voltage rating.
• Future-oriented, flexible solutions
• An HVDC point-to-point transmission as a response to varying power market
system, which can optionally expand requirements
into a multi-terminal system with
• Ability to provide grid access of renewable
three or more converter stations.
energy sources
• Power exchange between interconnected
systems and between asynchronous grids
• Economic, adaptable, and compact
solutions
• Maintenance-friendly, safe, and reliable
design with comprehensive lifetime
services
3
HVDC PLUS:
the best technology for
sustainable success
4
Operational
advantages
• A very high level of system
reliability, and redundancy
for all key components
of the converter control.
• Standard control and
protection system; hardware
and software in hot standby
The compact footprint can be further Prize-winning health and and proven in practice
reduced e.g. using gas-insulated 320 kV safety compliance
• Minimized maintenance and
DC compact switchgear. Compared with We have a clearly defined goal for all our
service requirements
air insulation, the gas-insulated solution HVDC transmission projects: apply the
reduces space requirements for the • Compact station design with
highest possible safety standard in order
little high-voltage equipment
DC switchyard by up to 90 percent. to reduce the number of incidents to zero. and typically no harmonic
Our HVDC systems are designed using a filters
Stabilization of AC network risk-based engineering approach to assure
• Black-start capability to
HVDC PLUS is completely appropriate for a risk-free and safe design, a “safety-first” improve speed of recovery
steady state and dynamic AC voltage con- construction process, and the safe operation of interconnected grids
trol, independently on each station. Its of the systems. All projects are executed
typical advantages are apparent when with the highest health and safety aware-
weak AC networks are b eing connected: ness on the part of our management,
• Low dependency on short-circuit employees, and partners. Our team on the
power, voltage, and frequency New Zealand Pole 3 project was recently
of the AC networks. awarded for outstanding safety achieve-
ments.
• Reactive power can be generated or
consumed independent of active power
transmission.
• Unbalance control for compensation
of large single phase loads
• During AC transmission network resto-
ration (for example, after a blackout),
HVDC PLUS can provide system recovery
ancillary service (SRAS).
5
HVDC PLUS:
the solution for flexible DC power transmission systems
several 100 km
Long-distance Back-to-back
AC AC AC AC
6
1 Converter transformers
3
1 2 2 Cooling
3 AC switchyard
4
4 Control and protection
7
5
5 DC compact switchgear
6 DC yard
6
7 Converter hall
7
Half-bridge converter topology
for optimized power transmission
Uac
Udc
Udc
0
Uac
“on” “off”
8
Full-bridge technology
for utmost reliability
Uac
Udc
Udc Uac
0
–Udc
9
Optimized support from
an experienced partner
10
Technical clarifications
Financing support and consulting Overall project management
Site facilities
Training
and civil works
Transport Procurement
Factory testing
11
Project references
12
Flexible operation of HVDC link
during changing AC system configurations
Three individual active power control modes
of operation are available:
• Power set-point control regulates the HVDC according
to the utilities’ dispatched active power set points. This
control mode is typically required during asynchronous
network operation, where all parallel AC lines are out
of service or unavailable.
• External power control regulates the HVDC’s ordered Converter station at Baixas in France
13
Project references
SylWin 1
Czech
Republic
France
Philippsburg
14
Customer: Trans Bay Cable, LLC Operational highlights:
HVDC PLUS enhances the performance of the transmission
Location: Pittsburg (California) –
grid, improves reliability, and reduces maintenance costs.
San Francisco (California), USA
HVDC PLUS is the preferred solution in space-constrained
Type of plant: HVDC PLUS in half-bridge topology urban environments like San Francisco. After successful
connected via an 86 km submarine commissioning in November 2010, the Trans Bay Cable
cable Project met the California Independent System Operator’s
(ISO) planning and reliability standards. The system was
Power rating: 400 MW, symmetrical monopole upgraded to black-start capability in 2016.
Voltage levels: ± 200 kV DC,
230 kV/115 kV AC, 60 Hz
15
Published by
Siemens AG 2016
Energy Management Division
Freyeslebenstrasse 1
91058 Erlangen, Germany
For more information, please contact
our Customer Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
E-mail: support.energy@siemens.com
Article No. EMTS-B10016-00-7600
Printed in Germany
Dispo 30003
TH 263-160390 BR 1216
Subject to changes and errors.
The information given in this document only contains
general descriptions and/or performance features
which may not always specifically reflect those
described, or which may undergo modification in
the course of further development of the products.
The requested performance features are binding
only when they are expressly agreed upon in the
concluded contract.