You are on page 1of 10

PROPOSED RESIDENTIAL DEVELOPMENT AT

PLOT 108 BUSIRO, MENGO DISTRICT


Architectural Drawings Set
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
E-03 HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

11,600
2. THE CONTRACTOR SHALL VERIFY ALL
DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
WITH ANY WORK.

200 3,000 150 5,550 200 1,800 200 300 200 3. THE CONTRACTOR SHALL NOTIFY AGAE
OF ANY CONFLICT OR DISCREPANCY

919 1,500 1,379 2,000 1,042 1,500 760 1,800 200 300 200
DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE
SITE.
4. CONSTRUCTION SHALL NOT PROCEED UNTIL

A
CORRECTIONS HAVE BEEN MADE AND RELATED
PLANS OR CLARIFICATIONS HAVE BEEN RE -
ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.

600
600

200
200
W-02 W-01 W-02 5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
MASONRY WALLS, RING BEAMS, RAFTERS AND

600
2,000 TRUSSES. SPECIAL ATTENTION MUST BE MADE

200
TO THE LOCATION OF EACH DIMENSION LINE.

900
THIS IS CRITICAL SINCE IT MAY VARY .

1,800
3,000

2,000
6. EXTERIOR SLABS, AND WALKWAYS WILL BE
SLOPED AT A MINIMUM OF 1% AWAY FROM

2,200
BUILDING.

900
D-04
3,000

3,000
3,624

200
KITCHEN
BEDROOM

450 300 300


±0.000 8.250 m2
8.925 m2 ±0.000
±0.000
Porcelain Tiles

1,000
600
W-04
Porcelain Tiles DINING

1,200
800
ROOM
200

8.400 m2 2,750
Porcelain Tiles WC
4.805 m2
WC D-02 ±0.000
1,100

1,500
CORRIDOR
600

W-04

Porcelain Tiles

1,100

1,100

600
W-04
D-02
2

D-03
5.940 m

D-03
±0.000

8,900
Porcelain Tiles ±0.000 2,350
D-02 Porcelain Tiles

4,200
1,426
200

450
1,200
LIVING ROOM

E-02
E-04

10,725

BEDROOM 14.700 m2 Rev. Date Description

1,839
±0.000
10.426 m2 MASTER BEDROOM
Revisions :
±0.000 Porcelain Tiles

2,100
14.285 m2 Client :
Porcelain Tiles ±0.000
Nakiganda Milly
1,500

Porcelain Tiles
3,500

W-02

3,500
+256 788 812 767

4,000
Client's Signature :

1,500
...........................

2,161
W-02
600 200

3,000 D-01
Project title :

Proposed Residential Development at


3,050

Block Number 424, Plot Number 1081

600
W-03 W-03
W-01 Busiro County, Mengo
VERANDAH

200
1,800

8.145 m2 W-02
1,200

-0.100
Master Plan :
Porcelain Tiles
600

1,500

2,000 Building Trade :


Architectural and Mechanical Drawings
Drawing title :
A

285 MH GROUND PLAN

834 600 600 1,231 1,500 400 2,000 1,076 1,500 1,074
200 3,000 150 4,150 200 3,200 200 Date of Issue :

18/08/2021

11,100 Drawn by:


LB

Checked by:
OD

E-01
Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 02
MH GROUND PLAN (1:75) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL


DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
WITH ANY WORK.

3. THE CONTRACTOR SHALL NOTIFY AGAE


OF ANY CONFLICT OR DISCREPANCY
DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE
SITE.
4. CONSTRUCTION SHALL NOT PROCEED UNTIL
CORRECTIONS HAVE BEEN MADE AND RELATED
PLANS OR CLARIFICATIONS HAVE BEEN RE -
ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.
5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
Roof Level Roof Level Roof Level Roof Level
5,460 5,460 5,460 5,460 MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE
TO THE LOCATION OF EACH DIMENSION LINE.
THIS IS CRITICAL SINCE IT MAY VARY .
Floor Level
4.575
6. EXTERIOR SLABS, AND WALKWAYS WILL BE
SLOPED AT A MINIMUM OF 1% AWAY FROM
Roof Level BUILDING.
4,440

Beam Level Beam Level Beam Level Beam Level


2,400 2,400 2,400 2,400

Window Level
0.900

Floor Level Floor Level Floor Level


0.000 0.000 0.000 Floor Level
-0.100

Floor Level Floor Level Floor Level Floor Level


-0.550 -0.550 -0.550 -0.550

Rev. Date Description


ELEVATION E-03 ELEVATION E-04 Revisions :

Client :
Nakiganda Milly
Roof Level Roof Level Roof Level Roof Level +256 788 812 767
5,460 5,460 5,460 5,460

Client's Signature :
Floor Level
4.575

...........................
Roof Level
4,440
Project title :

Proposed Residential Development at


Block Number 424, Plot Number 1081
Beam Level Beam Level Beam Level Beam Level
2,400 2,400 2,400 2,400 Busiro County, Mengo

Master Plan :

Window Level
0.000

Floor Level Floor Level Floor Level


0.600 0.000 Floor Level 0.000
-0.100

Floor Level Floor Level Floor Level Floor Level


-0.550 -0.550 -0.550 -0.550

ELEVATION E-01 ELEVATION E-02


Building Trade :
Architectural and Mechanical Drawings
Drawing title :
MH ELEVATIONS

Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 03
MH ELEVATIONS (1:100) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

ROOF NOTES 2. THE CONTRACTOR SHALL VERIFY ALL


DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
Roof Pitch at 200 WITH ANY WORK.

28 guage prepainted Iron sheets on 3. THE CONTRACTOR SHALL NOTIFY AGAE

75x50mm timber purlins on CEILING NOTES OF ANY CONFLICT OR DISCREPANCY


DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE

150x50mm timber rafters with Cement Sand plaster ceiling casted on SITE.

100x50mm ties and struts on Metal lathe fastened on 4. CONSTRUCTION SHALL NOT PROCEED UNTIL
CORRECTIONS HAVE BEEN MADE AND RELATED
PLANS OR CLARIFICATIONS HAVE BEEN RE -

150x50mm tie beam on 50x50mm timber joists and branderings at ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.

100x75 timber wall plate 600 c/c 5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
Roof Level Roof Level MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE
5,460 5,460 TO THE LOCATION OF EACH DIMENSION LINE.
THIS IS CRITICAL SINCE IT MAY VARY .
1,87
6 6. EXTERIOR SLABS, AND WALKWAYS WILL BE
SLOPED AT A MINIMUM OF 1% AWAY FROM
BUILDING.
1,299
Floor Level
6
5,32 4.575

3,18
6

25°

230x300
230 370

230 370

230 370

364 266 370


RING BEAM
Kitchen Corridor Verandah
Beam Level
2,400
Living Room Beam Level
2,400
Rev. Date Description
Revisions :

Client :
1,800

Nakiganda Milly
2,800

+256 788 812 767


2,400

2,400

2,100
Client's Signature :

...........................
900

FFL
600

Project title :
0.000 FFL
-0.100 Proposed Residential Development at
Floor Level
0.000 Floor Level Block Number 424, Plot Number 1081
400

-0.100
Busiro County, Mengo
Floor Level Floor Level
-0.550 -0.550
Master Plan :

Floor Notes
Foundation Notes Approved floor finish on
230mm thick masonry brick work on 150mm thick concrete slab reinforced with
Building Trade :
Architectural and Mechanical Drawings
100mm concrete blinding A142 BRC on Drawing title :

(690mm strip foundation) 1000 guage dpm sheeting on


MH SECTIONS

50mm blinding treated with antitermite


on 350mm well compacted hardcore on rammed earth Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 04
MH SECTIONS (1:50) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE

E-03 CONTRACTOR'S SOLE RESPONSIBILITY TO


FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL


DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
WITH ANY WORK.

12,300 3. THE CONTRACTOR SHALL NOTIFY AGAE


OF ANY CONFLICT OR DISCREPANCY
DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE
SITE.
4. CONSTRUCTION SHALL NOT PROCEED UNTIL
CORRECTIONS HAVE BEEN MADE AND RELATED

A
PLANS OR CLARIFICATIONS HAVE BEEN RE -
ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.
5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE
TO THE LOCATION OF EACH DIMENSION LINE.
THIS IS CRITICAL SINCE IT MAY VARY .

SLOPE 25O 6. EXTERIOR SLABS, AND WALKWAYS WILL BE

3,200
SLOPED AT A MINIMUM OF 1% AWAY FROM
BUILDING.

6,7

88
88

6,7

09
1,9
SLOPE 25O

2,700

2,700
9,600

SLOPE 25O 4,1


72
11,400

11,400

E-02
E-04

Rev. Date Description


Revisions :

Client :
Nakiganda Milly
+256 788 812 767
88

52
6,7

SLOPE 25O
6,4
Client's Signature :

6,4
52

4,200
...........................

Project title :

Proposed Residential Development at


SLOPE 25O Block Number 424, Plot Number 1081
Busiro County, Mengo

4,0
48
4,0

48
Master Plan :
1,800

1,300
SLOPE 25O

Roofing Sheets Building Trade :


Architectural and Mechanical Drawings
Total Surface = 145.022 m² Drawing title :
ROOF PLAN
A

3,175 5,725 3,400 Date of Issue :

12,380
18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

E-01 Scale :
As Shown
Paper size :

A3
Job Number : Drawing Number :
ARD 05
ROOF PLAN (1:75) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL

E-B3
DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
WITH ANY WORK.

3. THE CONTRACTOR SHALL NOTIFY AGAE


OF ANY CONFLICT OR DISCREPANCY
DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE

600 10,700 600 SITE.


4. CONSTRUCTION SHALL NOT PROCEED UNTIL
CORRECTIONS HAVE BEEN MADE AND RELATED
PLANS OR CLARIFICATIONS HAVE BEEN RE -
ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.

600 200 1,532 150 1,218 200 4,000 200 3,000 200 600 5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE

B
TO THE LOCATION OF EACH DIMENSION LINE.
200

THIS IS CRITICAL SINCE IT MAY VARY .


274

6. EXTERIOR SLABS, AND WALKWAYS WILL BE


SLOPED AT A MINIMUM OF 1% AWAY FROM
BUILDING.
1,200

1,450
D-B3
W-B3
600

BEDROOM
1,226
150

4,100
BEDROOM
4,300

4,300
1,500
W-B2
E-B4

E-B2
LIVING ROOM

D-B2

D-B2
1,500
2,650

Rev. Date Description


W-B2

D-B1
Revisions :

Client :
Nakiganda Milly

1,150
+256 788 812 767

W-B1 Client's Signature :


600

...........................
600 200

600 200
600 200
600

600
Project title :

W-B2 W-B2 Proposed Residential Development at


Block Number 424, Plot Number 1081
Busiro County, Mengo

B Master Plan :

600 200 2,900 200 4,000 200 3,000 200 600


600 900 1,500 900 1,200 600 2,000 2,691 909 600
600 10,700 600
Building Trade :
Architectural and Mechanical Drawings
Drawing title :

E-B1
BOYS QAURTERS

Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 06
BOYS QAURTERS (1:50) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL


DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
WITH ANY WORK.

3. THE CONTRACTOR SHALL NOTIFY AGAE


OF ANY CONFLICT OR DISCREPANCY
DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE
SITE.
Roof Level Roof Level Roof Level 4. CONSTRUCTION SHALL NOT PROCEED UNTIL
4,300 4,300 4,300
CORRECTIONS HAVE BEEN MADE AND RELATED
PLANS OR CLARIFICATIONS HAVE BEEN RE -
ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.
5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE
TO THE LOCATION OF EACH DIMENSION LINE.
THIS IS CRITICAL SINCE IT MAY VARY .
Beam Level Beam Level Beam Level
2,400 2,400 2,400 6. EXTERIOR SLABS, AND WALKWAYS WILL BE
SLOPED AT A MINIMUM OF 1% AWAY FROM
BUILDING.

Window Level Window Level Window Level


0.000 0.000 0.000

Floor Level Floor Level Floor Level


0.600 0.600 0.600

Floor Level Floor Level Floor Level


-0.550 -0.550 -0.550

ELEVATION E-B3 ELEVATION E-B4 Rev. Date Description


Revisions :

Client :
Nakiganda Milly
+256 788 812 767

Client's Signature :

Roof Level Roof Level Roof Level


4,300 4,300 4,300 ...........................

Project title :

Proposed Residential Development at


Block Number 424, Plot Number 1081
Busiro County, Mengo
Beam Level Beam Level Beam Level
2,400 2,400 2,400

Master Plan :

Window Level Window Level Window Level


0.000 0.000 0.000

Floor Level Floor Level Floor Level


0.600 0.600 0.600
Building Trade :

Floor Level Floor Level Floor Level Architectural and Mechanical Drawings
-0.550 -0.550 -0.550
Drawing title :
BQ ELEVATIONS

ELEVATION E-B1 ELEVATION E-B2 Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 07
BQ ELEVATIONS (1:75) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL


DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
ROOF NOTES WITH ANY WORK.

Roof Pitch at 70 3. THE CONTRACTOR SHALL NOTIFY AGAE


OF ANY CONFLICT OR DISCREPANCY
28 guage prepainted Iron sheets on DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE

75x50mm timber purlins on


SITE.
4. CONSTRUCTION SHALL NOT PROCEED UNTIL
150x50mm timber rafters with CORRECTIONS HAVE BEEN MADE AND RELATED
PLANS OR CLARIFICATIONS HAVE BEEN RE -

100x50mm ties and struts on ISSUED. CONSTRUCTION CAN ONLY BEGIN


AFTER THE ISSUE(S) HAS BEEN RESOLVED.

150x50mm tie beam on 5. DRAWING DIMENSIONS ARE EITHER FROM


THE FACE OF OR FROM THE CENTER OF,

100x75 timber wall plate MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE
TO THE LOCATION OF EACH DIMENSION LINE.
THIS IS CRITICAL SINCE IT MAY VARY .

6. EXTERIOR SLABS, AND WALKWAYS WILL BE


Roof Level SLOPED AT A MINIMUM OF 1% AWAY FROM
Roof Level 4,300 BUILDING.
4,300

4,836

1,670
502

502
LIVING ROOM Beam Level

230

230

230
Beam Level 2,400
2,400

1,800
Rev. Date Description
Revisions :
2,400

2,400
Client :
Nakiganda Milly
Window Level +256 788 812 767
Window Level 0.000
0.000 Client's Signature :

600
Floor Level ...........................
Floor Level 0.600
0.600
Project title :
500

550
Floor Level Proposed Residential Development at
Floor Level -0.550
-0.550 Block Number 424, Plot Number 1081
Busiro County, Mengo

Master Plan :

Foundation Notes Floor Notes


230mm thick masonry brick work on Approved floor finish on
100mm concrete blinding 150mm thick concrete slab reinforced with
(690mm strip foundation) A142 BRC on Building Trade :
Architectural and Mechanical Drawings
1000 guage dpm sheeting on Drawing title :

50mm blinding treated with antitermite BQ SECTION

on 350mm well compacted hardcore on rammed earth


Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 08
BQ SECTION (1:50) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL


Door Schedule BQ Door Schedule DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING
Element ID D-01 D-02 D-03 D-04 Element ID D-B1 D-B2 D-B3 WITH ANY WORK.
1,500
40 320 40 1,060 40 900 800 900 1,200 900 800 3. THE CONTRACTOR SHALL NOTIFY AGAE
OF ANY CONFLICT OR DISCREPANCY

300

300

300

300

300

300

300
DISCOVERED BETWEEN THE DRAWINGS AND
ACTUAL CONDITIONS ENCOUNTERED ON THE
SITE.
4. CONSTRUCTION SHALL NOT PROCEED UNTIL
Elevations Elevations

2,400

2,400

2,400

2,400

2,400

2,400

2,400
CORRECTIONS HAVE BEEN MADE AND RELATED

2,100

2,100

2,100

2,100

2,100

2,100

2,100
PLANS OR CLARIFICATIONS HAVE BEEN RE -
ISSUED. CONSTRUCTION CAN ONLY BEGIN
AFTER THE ISSUE(S) HAS BEEN RESOLVED.
5. DRAWING DIMENSIONS ARE EITHER FROM
THE FACE OF OR FROM THE CENTER OF,
MASONRY WALLS, RING BEAMS, RAFTERS AND
TRUSSES. SPECIAL ATTENTION MUST BE MADE
Quantity 1 3 2 1 Quantity 1 2 1 TO THE LOCATION OF EACH DIMENSION LINE.
THIS IS CRITICAL SINCE IT MAY VARY .
W x H Size 1,500×2,400 900×2,400 800×2,400 900×2,400 W x H Size 1,200×2,400 900×2,400 800×2,400
6. EXTERIOR SLABS, AND WALKWAYS WILL BE
SLOPED AT A MINIMUM OF 1% AWAY FROM
BUILDING.
Description Metallic frame single Description Metallic frame single
Timber panneled door Timber panneled door Metallic frame single Timber panneled door Timber panneled door
leaf side hinged door leaf side hinged door
leaf side hinged door
with sidelights with sidelights
Glazing Leaf: 6mm clear glass Leaf: timber Leaf: timber Leaf: 6mm clear glass Glazing Leaf: 6mm clear glass Leaf: timber Leaf: timber

Transom: Louvered Transom: 6mm glass Transom: 6mm glass Transom: Louvered Transom: Louvered Transom: 6mm glass Transom: 6mm glass

Location Location
Main Entrance Internal doors WCs Kitchen Main Entrance Internal doors WC

Iron mongery Iron mongery

Rev. Date Description


Revisions :

Window Schedule BQ Window Schedule Client :


Element ID W-01 W-02 W-03 W-04 Element ID W-B1 W-B2 W-B3 Nakiganda Milly
+256 788 812 767
2,000 600 2,000
100 301

50 225 50 1,125 50 50 225 50 1,125 50


Client's Signature :
600 600

460 86 254

460 86 254
100 749

Elevations Elevations ...........................


1,800

1,500

1,800

1,800

1,500
800

800
500

Project title :

Proposed Residential Development at


50

Block Number 424, Plot Number 1081


Quantity 2 5 2 3 Quantity 1 4 1 Busiro County, Mengo
Size 2,000×1,800 1,500×1,500 600×1,800 600×800 Size 2,000×1,800 1,500×1,500 600×800
Sill height 600 900 600 1,600 Sill height 600 900 1,600
Master Plan :
Head height 2,400 2,400 2,400 2,400 Head height 2,400 2,400 2,400

Description Metallic frame sliding Metallic frame window Metallic frame Top Metallic frame Top Description Metallic frame sliding Metallic frame window Metallic frame Top
window variable pane Hung Hung window variable pane Hung

Glazing Panes: 6mm clear Panes: 6mm clear Panes: 6mm clear Panes: 6mm frosted Glazing Panes: 6mm clear Panes: 6mm clear Panes: 6mm frosted
glass glass glass glass glass glass glass
Transom: Steel louvres SideVent: Steel Transom: Steel louvres Transom: Steel louvres Transom: Steel louvres SideVent: Steel Transom: Steel louvres
louvres louvres
Location Living Room Bedroom 01, Bedroom Location Building Trade :

Dining Room 02, Master Bedroom, Bedroom 01, Washrooms Living Room Bedrooms Washroom Architectural and Mechanical Drawings
Kitchen Drawing title :
OPENINGS SCHEDULES
Iron mongery Iron mongery

Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 09
OPENINGS SCHEDULES (1:100) MN21-37
Notes :
1. ALL WORK TO BE DONE IN ACCORDANCE
WITH ALL APPLICABLE CODES AND AGENCIES
HAVING JURISDICTION . IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO
FOLLOW ALL APPLICABLE SAFETY CODES AND
REGULATIONS DURING ALL PHASES OF
CONSTRUCTION.

2. THE CONTRACTOR SHALL VERIFY ALL


DIMENSIONS, ELEVATIONS OF DRAWINGS AND
EXISTING CONDITIONS BEFORE PROCEEDING

18,484 WITH ANY WORK.

B
3. THE CONTRACTOR SHALL NOTIFY AGAE
OF ANY CONFLICT OR DISCREPANCY
9,900 DISCOVERED BETWEEN THE DRAWINGS AND

D-B3
BOYS
W-B3

BEDROOM ACTUAL CONDITIONS ENCOUNTERED ON THE


SITE.
BEDROOM
WATER 4. CONSTRUCTION SHALL NOT PROCEED UNTIL

QUARTER

W-B2
SPACE FOR FUTURE
LIVING ROOM
CORRECTIONS HAVE BEEN MADE AND RELATED

D-B2

D-B2
BOYS TANK

6,000
PLANS OR CLARIFICATIONS HAVE BEEN RE -
4,600

W-B2

D-B1
Average 2% Slope QUARTERS ISSUED. CONSTRUCTION CAN ONLY BEGIN
for surface drain to W-B1 AFTER THE ISSUE(S) HAS BEEN RESOLVED.
soak pit
5. DRAWING DIMENSIONS ARE EITHER FROM
W-B2 W-B2
THE FACE OF OR FROM THE CENTER OF,
12,300 MASONRY WALLS, RING BEAMS, RAFTERS AND
B TRUSSES. SPECIAL ATTENTION MUST BE MADE

A
GT MH
TO THE LOCATION OF EACH DIMENSION LINE.
W-02 W-01 W-02 2,064 THIS IS CRITICAL SINCE IT MAY VARY .

6. EXTERIOR SLABS, AND WALKWAYS WILL BE


SLOPED AT A MINIMUM OF 1% AWAY FROM
BUILDING.
BUILT-UP AREA

D-04
KITCHEN
BEDROOM ±0.000 8.250 m2
8.925 m2
±0.000
±0.000
Porcelain Tiles
GT

W-04
Porcelain Tiles DINING
ROOM
8.400 m2
AREA IN SQUARE
Porcelain Tiles WC
4.805 m2
NAME METERS
WC D-02 ±0.000

MAIN
MH CORRIDOR
9,600

W-04

Porcelain Tiles

W-04
D-02

5.940 m2
D-03

D-03 MH
±0.000
Porcelain Tiles
D-02
±0.000
Porcelain Tiles Site 573.00
GT LIVING ROOM

BUILDING
14.700 m2
BEDROOM
10.426 m2
±0.000
±0.000
Porcelain Tiles MASTER BEDROOM
Main Building 134
14.285 m2
Porcelain Tiles ±0.000
Porcelain Tiles
W-02

31,679
W-02

ACCESS ROAD
D-01

2,350 W-03 W-03


W-01
TOTAL 134
VERANDAH
8.145 m2 W-02
MH
74

-0.100
Porcelain Tiles
Outdoor Space (Hard and Soft Landscapes) 389 .0
2,6

MH

Plot Coverage 91 %
6,238

Built-up ratio 0.91


38,5

Rev. Date Description


A

Avera
for su ge 2% Slo Revisions :
rface pe
soak drain to
MH pit
Client :
18

PAVED Nakiganda Milly


TIC AREA PLUMBING AND DRAINAGE LEGEND
SEP TO +256 788 812 767
K
TAN TE
SI N SYMBOL NAME SYMBOL NAME
TIO
NDI Client's Signature :
CO
Kitchen Sink
MH
Waste water drainage pipes (Ø40) and foul ...........................
water drainge pipes (Ø110mm)
Corner handwash Basins
PARKING Project title :
SPACE
Proposed Residential Development at
4,501

Floor drain Handwash Basin


GATE

Block Number 424, Plot Number 1081


9,47

SOAK AWAY
0

PIT TO SITE
CONDITION Busiro County, Mengo
GT Gully trap Western type toilet

Avera
for su ge 2% Slo
rface pe Master Plan :
soak drain to MH
pit
Manhole Shower location with tiled floor and walls - no shower tray
SOA
DRA NEL
CHA

K AW E
INAG
N

7
7,87
40
AY

200
4,0

9
Building Trade :

7,83
Architectural and Mechanical Drawings
Drawing title :
SITE MAP

Date of Issue :

18/08/2021

Drawn by:
LB

Checked by:
OD

Approved by:

Scale : Paper size :


As Shown A3
Job Number : Drawing Number :
ARD 10
SITE MAP (1:200) MN21-37

You might also like