Professional Documents
Culture Documents
LOGIQ P9
Make it easy. Make it your own.
Product description
The LOGIQ™ P9 is a highly capable ultrasound system that
provides excellent image quality and productivity through
easy to use tools across a wide range of applications in a
portable, ergonomic, budget-friendly system design.1
General Specification System Overview
Dimensions and Weight: Applications
Height Articulating monitor arm Abdominal
(option) 1320 mm ~ 1570 mm
(52.0 in ~ 61.8 in) Obstetrical
Advanced 3D
Display Modes
Cable hook rear
Live and stored display format: full size and split screen – both
Card reader mounting kit with “thumbnails” for still and Cine
Elastography Review image format: 4x4 and “thumbnails” for still and Cine
Elastography Quantification3
Simultaneous capability
System Overview (cont.)
Display Modes (cont.) Display Annotation (cont.)
B or CrossXBeam/PW Displayed acoustic output • TIS: Thermal Index
Soft Tissue
B or CrossXBeam/CFM or PDI • TIC: Thermal Index
B/M Cranial (Bone)
• TIB: Thermal Index Bone
B/CrossXBeam • MI: Mechanical Index
Real-time Triplex Mode (B or CrossXBeam + CFM or PDI/PW or % of maximum power output
CW (option)
Probe name
Selectable Alternating Modes
Map names
B or CrossXBeam/PW
Probe orientation
B or CrossXBeam + CFM (PDI)/PW(CW (option))
Depth scale marker
B/CW (option)
Lateral scale marker
Multi-image (split/quad screen)
Focal zone markers
Live and/or frozen
Image depth
B or CrossXBeam + B or CrossXBeam/CFM or PDI
Zoom depth
Independent Cine playback
B-Mode
Timeline display
Gain
Independent dual B or CrossXBeam/PW display
Dynamic range
CW
Imaging frequency
Display formats • Top/bottom selectable
format Frame averaging
• Side/side selectable format Acoustic frame rate
Virtual convex Gray map
Timeline only SRI-HD
M-Mode
Display Annotation
Gain
Patient Name: first, last and middle
Dynamic range
Patient ID
Time scale
2nd patient ID
Doppler mode
Age, sex and birth date
Gain
Hospital name
Angle
Date format: • MM/DD/YY
3 types selectable • DD/MM/YY Sample volume depth and width
• YY/MM/DD
Wall filter
Time format: • 24 hours
Velocity and/or frequency scale
2 types selectable • 12 hours
Spectrum inversion
Gestational age from • LMP
• GA Time scale
• EDD
• BBT PRF
Doppler frequency
System Overview (cont.)
Display Annotation (cont.) Complete User Manual Available On-Board Through Help (F1)
Color Flow Mode User manual and service manual are included on CD with
each system. A printed manual is available upon request.
Line density
Frame averaging
CINE Memory/Image Memory
Packet size
776 MB of Cine memory
Color scale: 3 types • Power
Selectable cine sequence for Cine review
• Directional PDI
• Symmetrical velocity Prospective Cine mark
imaging
Measurements/calculations and annotations on Cine playback
Color velocity range and baseline
Scrolling timeline memory
Color threshold marker
Dual image Cine display
Color gain
Quad image Cine display
PDI
Cine gauge and Cine image number display
Inversion
Cine review loop
Doppler frequency
Cine review speed
TGC curve
Cine gage, image number/frame number Image Storage
Body pattern: multiple human and animal types On-board database of patient information from past exams
Application name Storage formats: • DICOM – compressed/
Measurement results uncompressed, single/
multiframe, with/without
Operator message raw data
• Export JPEG, JPEG2000,
Biopsy guide line and zone
WMV, MPEG 4 and AVI
Heart rate formats
Storage devices: • USB memory Stick: 64 MB
to 4 GB (for exporting
General System Parameters individual images/clips)
• CD-R storage: 700 MB
• DVD storage: -R (4.7 GB)
System Setup
• Hard drive image storage:
Pre-programmable categories ~345 GB
User programmable preset capability Compare old images with current exam
Accumulation
TVI (Option)
Coded Contrast Imaging (Option) Myocardial doppler imaging with color overlay on tissue image
2 contrast timers Tissue color overlay can be removed to show just the 2D
image, still retaining the tissue velocity information
Timed updates: 0.05 – 10 seconds
Curved anatomical M-Mode: free (curved) drawing of M-Mode
Accumulation mode, six levels generated from the cursor independent from the axial plane
Maximum Enhance Mode Q-Analysis: multiple time motion trace display from selected
Flash points in the myocardium
Number of angles for CrossXBeam Max Read Zoom to 8x: baseline shift
Gain PW Mode
Fetal graphical trending SYS PECA (Systolic Proximal External Carotid Artery)
8C-RS 9L-RS
E8CS-RS L8-18i-RS
Imagination at work
Product may not be available in all countries and regions. Full product technical
specification is available upon request. Contact a GE Healthcare Representative for
more information. Please visit www.gehealthcare.com/promotional-locations
Data subject to change.
© 2016 General Electric Company.
GE, the GE Monogram, imagination at work, LOGIQ, B-Flow, InSite and CrossXBeam
are trademarks of General Electric Company.
DICOM is the registered trademark of the National Electrical Manufacturers Association
for its standards publications relating to digital communications of medical information.
GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General Electric
company, doing business as GE Healthcare.
Reproduction in any form is forbidden without prior written permission from GE.
Nothing in this material should be used to diagnose or treat any disease or condition.
Readers must consult a healthcare professional.
May 2016
DOCXXXXXXX