 Zoom/iZoom (Full Screen Zoom)
1 System Overview  FCI (Frequency Compound Imaging)
1.1 Application  B steer

 Emergency  ExFOV (Extended Field of View)

 Nerve  Post Processing


TM
 Musculoskeletal  Echo Boost

 Critical Care  3 or 1 active universal probe

 Abdomen ports(optional)
 Cardiology  120GB SSD

 Obstetrics  Built-in wireless adapter

 Gynecology  Built-in battery

 Urology  4 USB 3.0 ports

 Smart parts  Touch Gestures

 Vascular  iStorage

 Others  MedSight

1.2 Transducer types 1.5 Optional features


 Curved array transducer  Continuous Wave Doppler

 Linear array transducer  DICOM

 Phased array transducer  Shared Service Package

1.3 Imaging modes  Left Ventricular Opacification


TM
 B-Mode  iNeedle ( Needle Visualization
TM
 THI and PSH (Phase Shift Harmonic Enhancement)
Imaging)  Cart

 M-Mode  Table stand/ Wall mount

 Color Doppler Imaging  ECG module

 Power Doppler Imaging/Directional 1.6 Language support


PDI  Software: English, Chinese, German,

 Pulsed Wave Doppler Spanish, French, Italian, Portuguese,


 Continuous Wave Doppler Russian, Czech, Polish, Turkish,
 Left Ventricular Opacification (LVO) Norwegian, Serbian
1.4 Standard features  User manual: English, Chinese,

 B-Mode Dutch, French, German, Hungarian,


TM
 THI and PSH Italian, Polish, Portuguese, Serbian,
 M-Mode Spanish, Turkish
 Color Doppler Imaging  Soft keyboard input: English,

 Power Doppler Imaging and Chinese, French, German, Italian,


Directional PDI Portuguese, Finnish, Danish,
 Pulsed Wave Doppler Icelandic, Norwegian, Swedish,
TM
 iBeam (Spatial Compound Polish, Czech, Hungarian, Serbian,
Imaging) Turkish, Russian
TM
 iClear (Speckle Suppression
Imaging)
2 Physical Specification
TM
 iTouch (Auto Image Optimization) 2.1 Dimension and weight
 Smart Track  Depth: 97mm

2
Mindray Confidential
Version 01.02.00 Oct. 2015
Width: 295mm 802.11n: up to 300Mbps
Height: 380mm 2.6 Built-in Battery
 Weight: Approx. 6.1Kg (three probe  Replaceable and rechargeable

socket configuration, with probe lithium battery


holders, no peripherals or batteries)  Light indicator

(battery weight: 0.9Kg)  Full battery lasts more than 22h in

2.2 Monitor standby mode


 15-inch high resolution color LED  Empty battery recharged to full in

monitor less than 4h


 Resolution: 768*1024  Continuous work time: more than 2

 Viewing angle: 85°left/right; 85° hours


up/down  Lithium-Ion Battery Pack 14.8V,

 Digital on-screen display of 5800mAh (single battery)


brightness and contrast controls 2.7 Probe port and holder
 Frame rate (Hz): 60Hz  Probe ports: max. 3 active ports

2.3 Cart (Option)  Detachable probe holder: 4

 DCU independent tilt of 50 degrees 2.8 Electrical power


up, 5 degrees down.  Voltage: 100-240V~

 Dimension and Weight(with DCU)  Frequency: 50/60 Hz

- Height: 1266-1556mm  Input current: 2.0A (115VAC)

- Width: 535mm 2.9 Operating Environment


- Depth: 620mm  Ambient temperature: 0-40 °C

- Weight: approx. 50Kg  Relative humidity: 30%-85% (no

 Wheels condensation)
- Diameter: 125mm  Atmospheric pressure:

- Castors (4): total lock and break 700hPa-1060hPa


 Towelette holster 2.10 Storage & Transportation
 Gel holder Environment
 Printer holder  Ambient temperature: -20-55 °C

 Storage bin  Relative humidity: 20%-95% (no

2.4 Table stand (Option) condensation)


 DCU independent tilt of 50 degrees  Atmospheric pressure:

up, 5 degrees down. 700hPa-1060hPa


 Dimension and Weight(with DCU)

- Height: 248mm
3 User Interface
- Width: 196mm 3.1 System boot-up
- Depth: 239mm  Boot-up from complete shut-down

- Weight: approx. 2.5 Kg in less than 25 sec


2.5 Built-in Wireless adapter  Shut-down in less than 15 sec

 Encryption: WEP, WPA-PSK,  Restore from standby mode: about 3


WPA2-PSK sec
 Max transfer speed: 300Mbps 3.2 Comments
 Protocols: 802.11b: 11,5.5,2,1 Mbps;  Supports text input and arrow

802.11g: 54,48,36,24,18,12,9,6 Mbps;  Support freehand marking on touch

3
Mindray Confidential
Version 01.02.00 Oct. 2015
screen  Depth
Covers various applications  Max. frame rate
 User customizable  Acoustic output power

3.3 Body mark  TGC

 144 bodymarks for versatile  Dynamic range

application  Gain

3.4 Numbers of exam mode presets: 29  Focus number

system exam modes (unlimited  Focus position

number for user-defined ones)  FOV

3.5 Screen information*  Line density

 Common info:  Persistence

- Mindray logo  Horizontal Scale

- Hospital name,  L/R flip and U/D flip

- Acoustic power  Rotation

- Mechanical index  TSI

- Tissue thermal index  Gray Map

- ID, Last name, First Name, Middle  Tint map

initial, Gender, Age  Middle line

- Probe model 4.3 THI and PSHTM


- Operator  Available on all types of transducer
TM
- Focus position  Patented PSH technology, obtains
- Imaging parameters purer harmonic, better contrast
resolution, higher SNR, exceptional
*Not all items are listed in this part, detail high frequency harmonic
TM
info please refer to user manual  iClear available
 Image quality

4.4 M-mode
4 Imaging Parameters  Display formats

4.1 Overview  Acoustic output power

 Echo-enriched Beamforming  Dynamic range

 Up to 55296 channels  Gain

 Up to 8-beamforming  M sweep speeds

4.2 B-mode  M soften

 Display formats  Tint maps


TM
 iClear  Gray Map
TM
 iBeam  Edge enhance
TM
 iTouch 4.5 Color Doppler Imaging
 FCI  Steer
TM
 Echo Boost  Image quality

 Image quality  Max. frame rate

 B steer: available on linear  Acoustic output power

transducers  Gain

 ExFOV: available on convex, linear,  ROI size/position

and volume transducers  Scale

4
Mindray Confidential
Version 01.02.00 Oct. 2015
Baseline  CW PRF
Wall filter  Gain
 PRF  Dynamic range

 Packet size  Sweep speed

 Flow state  Wall filter

 Smooth  Invert

 B/C align  Auto invert

 Priority  Angle correction

 Color map  Quick angle

 Invert  Gray map

 Persistence  Tint map

 Line density  Time/frequency resolution

 Smart track  Auto calc

4.6 Power Doppler Imaging  Auto calc cycle

 Support directional power doppler  Trace area

 Image quality  Trace sensitivity

 Acoustic output power  Trace Smooth

 Dynamic range  Duplex/Triplex

 Gain 4.8 LVO(option)


 ROI size/position  Only available on P4-2s

 Scale  Dedicated left ventricle contrast

 Wall filter imaging tool


 PRF 4.9 iTouchTM
 Packet size  Auto image optimization

 Flow state  B-mode: gain, TGC

 Smooth  Color: gain

 B/C align  Power: gain

 Priority  PW: baseline, scale, PRF, WF

 Power map  For L12-4s under vascular, EM Vas

 Directional power map and carotid exam mode: iTouch also


 Persistence optimizes Color ROI and PW
 Line density sampling line
4.7 PW/CW-Mode (CW mode is an option) 4.10 Smart Track
 Display formats:  Continuously track the flow and

V2:3,V3:2,V3:1,FULL(V: vertical) detect the best color box position


 Image quality and angle in real time scanning
 Sample volume size  Only for L12-4s under vascular, EM

 SV position Vas and carotid exam mode


 PW Scale 4.11 Zoom
 CW Scale  Zoom: Pan zoom (read zoom)

 Baseline  iZoom: Expand the image to full

 PW Steer screen
 Volume 4.12 Quick Save
 PW PRF  Create a new exam mode by quickly

5
Mindray Confidential
Version 01.02.00 Oct. 2015
saving current image parameter Invert
settings  Power:
4.13 iNeedle (option) Smooth
 Needle visualization enhancement Dynamic range
 Available on all linear transducers Color Map
 Needle steer: -50, -40, -30, -20, 20, 30, Priority
40, 50 degrees (also supports slight Invert
adjustment in 2° increments)  PW:
Baseline
5 Cine Review and Post Processing Volume
5.1 Cine review Angle
 Available in all modes Speed
 Frame by frame manual cineloop Dyn Ra.
review or auto playback with Gray Map
variable speed Tint Map
 Maximum cine memory up to 32346 Invert
frames or 427s (M/PW) WF
 Retrospective and prospective Quick Angle
storage are available and length is Auto Calculate
pre-settable (Prospective: Max. time T/F Res
480s; Retrospective: Max. time: Auto Calc Cycle
120s ) Auto Calc Parameter
5.2 Post processing Trace Sensitivity
 B-mode: Trace Smooth
Dyn Ra. Trace Area
Gray Map  CW
Tint Map Baseline
iClear Volume
L/R Flip Speed
U/D Flip Dyn Ra.
Rotation Gray Map
H Scale Tint
Echo Boost Tint Map
 M-mode: Invert
Speed WF
Dyn Ra. T/F Res
Gray Map Angle
Tint Map Quick Angle
Edge Enhance
 Color:
6 Measurement/Analysis and
Baseline
Smooth
Report*
Color Map 6.1 Basic measurements
Priority - Depth

6
Mindray Confidential
Version 01.02.00 Oct. 2015
- Distance - Left/Right Kidney: Length, Width,
- Angle Height, Volume, Cortical Thickness
- Area: Ellipse, Trace - Bladder: Length, Width, Height,
- Volume :3-Distance Volume, micturition volume
- Length Ratio - Ureter Diameter
- Area Ratio - Pleural: Length, Width, Height,
- Time Volume
- Slope - Left/Right UQ: Length, Width,
- Heart Rate Height, Volume
- Velocity - Left/Right Iliac Aneurysm: Length,
- D Trace Width, Height
- PS/ED - Pelvis: Length, Width, Height,
 Automatic Doppler Spectrum Volume
Analysis - Pericardial Sac: Length, Width,
- Heart cycle pre-settable (1, 2, 3, 4, Height, Volume
5) - Prox Aorta Aneurysm: Length,
- Automatic real-time and Width, Height
retrospective tracing - Mid suprarenal Aorta Aneurysm:
- User configurable display of items Length, Width, Height
- Support PI, RI, TAMAX, TAMEAN, - Mid Infrarenal Aorta Aneurysm:
Volume Flow calculations Length, Width, Height
- Appropriate factory setting - Distal Aorta Aneurysm: Length,
according to applications Width, Height
6.2 Clinical option measurement package - Aorta Bif Aneurysm: Length, Width,
 Abdominal Height
- Liver  Gynecology
- Common Hepatic Duct - Cervix: Length, Width, Width
- Iliac Diameter - Uterus: Length, Width, Height,
- Gall Bladder: Length, Height, Wall Volume, Uterus Sum,
Thickness Endometrium Thickness
- Common Bile Duct - UT-L/CX-L
- Prox Abdominal Aorta Diameter - Ovary: Length, Width, Height,
- Mid Suprarenal Abdominal Aorta Volume
Diameter - Follicle: Length, Width, Height,
- Mid Infrarenal Abdominal Aorta Average Diameter, Volume
Diameter  Obstetrics
- Distal Abdominal Aorta Diameter - Early OB: CRL, BPD, FL, HUM, HC,
- Mid Suprarenal ABD Aorta AC, Amniotic Fluid
- Mid Infrarenal ABD Aorta - 2nd- 3rd Trimester: BPD, HC, OFD,
- Abdominal Aorta Bifurcate FL, AC, AF, HUM, FTA, THD, Cervix
Diameter L(Trace available), Ut A, Ovarian A,
- Inferior Vena Cava Ovarian V, FHR
- Distal Abdominal Aorta - Gestational Age
- Spleen: Length, Height, Width - Estimated Fetal Weight

7
Mindray Confidential
Version 01.02.00 Oct. 2015
- Fetal Biophysical Profile Stenosis D, Stenosis A, ICA/CCA
- Gestational Age and Fetal Weight - Lower Extremity Vein: C.Iliac V,
OB tables Ex.Iliac V, Pop V, TP Trunk V,
- Weight Percentile Peroneal V, P.Tib V, A.Tib V
 Cardiology - Femoral Vein: CFV, SFV, DFV
- LV Function (2D and M): Teichholz - TCD (Transcranial Doppler): ACA,
- Mitral Valve: MV VTI, MR VTI, MV MCA, PCA, AComA, PComA,
E/A Vertebral A, Basilar A
- Aorta Valve: AV VTI, AR DecT  Small Parts:

- PAEDP - Thyroid: Length, Height, Width,


- RVSP Volume
- CO(LVOT) - Isthmus Height
- Left Atrium Diam/Aorta Diam - Testis: Length, Height, Width,
- Left Atrium Area Volume
- Right Atrium Area - Left/Right Testicular: Length, Width,
- Mitral Valve E-wave Velocity Height, Volume
- Mitral Valve A-wave Velocity - Left/Right Epididymis: Length,
- Mitral Valve Acceleration Time Width, Height
- Mitral Valve Deceleration Time - Breast Mass: Length, Height, Width,
- Mitral Valve Isovolumic Relaxation Nip. Distance, Skin Distance
Time - Left/Right Thyroid Cyst: Length,
- TAPSE Width, Height, Volume
 Urology - Left/Right Epididymis: Aorta, Vein
- Prostate: Length, Width, Height, - Left/Right Testicular: Aorta, Vein
Volume 6.3 Report
- PPSA, PSAD  Specific report template by

- Scrotal Wall application


- Left/Right Ureter Diameter  Editable value in report

- Renal: Length, Width, Height,  Images selectable

Volume  Able to Export as PDF/RTF file

- Bladder: Length, Width, Height, * Not all measurements are listed in this
Volume, micturition volume part; For more detailed information
- Left/Right Kidney: Length, Width, please refer to the Operators’ Manual
Height, Volume, Cortical Thickness
- Left/Right Testis: Length, Width,
Height, Volume
7 Exam Storage and Management
- Left/Right Testicular: Length, Width, 7.1 Exam storage
Height, Volume  120GB SSD. More than 74GB internal

- Left/Right Epididymis: Length, hard drive for patient data storage


Width, Height  Capable to store up to approximate

- Left/Right Epididymis: Aorta, Vein 354313 single frames


- Left/Right Testicular: Aorta, Vein  Direct digital storage of single frame

 Vascular and cine 2D, color and Doppler.


- Carotid: CCA, ECA, ICA, Bulb, Vert A 7.2 Exam management

8
Mindray Confidential
Version 01.02.00 Oct. 2015
 iStationTM workstation dedicated for computer
patient exam management 8.4 MedSight
 Patient exam query/retrieve  DICOM Basic is mandatory

 Support review of current and past  Needs to be installed on mobile

exam terminal
 New exam, Activate exam, End exam  Support IOS 5.0 or above mobile

are available terminal


 Support measurements and  Transfer PC format images or clips

calculations on archived exam and from system to mobile terminal


images through WiFi
 Export images as
(BMP/JPG/TIFF/DCM/AVI format )
9 Transducers
 Support backup/send to USB devices 9.1 Curved array
(hide patient information); support  C5-2s

back up to DVD-RW media (ASUS - Application: Abdomen,


DVD). Gynecology, Obstetrics, Urology,
Emergency
8 Connectivity - Bandwidth:
8.1 Ethernet Network Connection 2.1-5.1MHz (-6dB)
 Cable connection 1.5-5.6MHz (-20dB)
 Wireless connection: built-in - Number of Elements:128
wireless adaptor - Biopsy Guide: NGB-015, multi
8.2 DICOM 3.0 angle, reusable
 DICOM basic (option)  C11-3s

-Verify (SCU, SCP) - Application: Abdomen, Pediatrics,


-Print Transcranial, Vascular, Small parts,
-Store Musculoskeletal
-Storage Commitment - Bandwidth:
-Media Exchange 4-10MHz (-6dB)
 DICOM Worklist (option, HL7 3-11.2MHz (-20dB)
supported) - Number of Elements: 128
 DICOM Query/Retrieve (option) - Biopsy Guide: NGB-018, multi
 DICOM Modality Performed angle, reusable
Procedure Step - MPPS (option)  V11-3Ws

 DICOM OB/GYN structure report - Application: Obstetrics,


(option) Gynecology, Urology
 DICOM Cardiac structure report - Bandwidth:
(option) 4-10MHz (-6dB)
 DICOM Vascular structure report 3-11.2MHz (-20dB)
(option) - Number of Elements: 160
 DICOM Breast Report (option) - Biopsy Guide: NGB-004, single
8.3 iStorage(included in UltraAssist) angle, reusable
 Direct network storage tool between 9.2 Linear
ultrasound system and personal  L12-4s

9
Mindray Confidential
Version 01.02.00 Oct. 2015
- Application: Vascular, Small parts,  L16-4Hs
Nerve, MSK - Application: MSK, Nerve,
- Bandwidth: Intraoperative, Vascular
4.2-11.8MHz (-6dB) - Bandwidth:
3-13MHz (-20dB) 6-12.5MHz (-6dB)
- Number of Elements: 192 3.5-16MHz (-20dB)
- Biopsy Guide: NGB-007, multi - Biopsy Guide: not available
angle, reusable 9.3 Phased array
 L14-6Ns  P4-2s

- Application: Vascular, Small parts, - Application: Cardiology, TCI,


Nerve, MSK, Superficial Abdomen, LVO
- Bandwidth: - Bandwidth:
5.1-12.5MHz (-6dB) 1.7-4.1MHz (-6dB)
3.5-16MHz (-20dB) 1.3-4.7MHz (-20dB)
- Number of Elements: 192 - Number of Elements: 64
- Biopsy Guide: NGB-007, multi - Biopsy Guide: NGB-011, multi
angle, reusable angle, reusable
 L14-6s  P7-3Ts

- Application: Vascular, Small parts, - Application: Transesophageal Echo


Nerve, MSK - Bandwidth:
- Bandwidth: 3.1-7.2MHz (-6dB)
5.1-12.5MHz (-6dB) 1.9-8.2MHz (-20dB)
3.5-16MHz (-20dB) - Number of Elements: 64
- Number of Elements: 128 - Biopsy Guide: not available
- Biopsy Guide: NGB-016, multi
angle, reusable
10 Peripheral Devices and
 L7-3s

- Application: Vascular, Small parts,


Accessories (Option)
Nerve, MSK 10.1 Black/white digital video printer
- Bandwidth:  SONY UP-D897, MITSUBISHI

3.4-6.9MHz (-6dB) P95DW-N


2.7-8.3MHz (-20dB) 10.2 Color digital printer
- Number of Elements: 128  SONY UP-D25MD

- Biopsy Guide: NGB-007, multi 10.3 Graph/text printer


angle, reusable  HP Deskjet 1050 J410 series, HP

 7LT4s Officejet 7000 wide format, HP


- Application: Intraoperative, MSK, Officejet Pro 8100
Vascular 10.4 Wireless printer
- Bandwidth:  HP Officejet Pro 8100

5-10MHz (-6dB) 10.5 Footswitch


3.5-13.5MHz (-20dB)  USB port: 971-SWNOM (2-pedal)

- Number of Elements: 128  USB port: 971-SWNOM (3-pedal)

- Biopsy Guide: NGB-010, multi  Wireless: WFREC-1(Receiver) +

angle, reusable WFSW-2/WFSW-3 (Footswitch)

10
Mindray Confidential
Version 01.02.00 Oct. 2015
10.6 Barcode reader  EN 62304 and IEC 62304
 Laser barcode scanner  EN 62366 and IEC 62366
 Model: SYMBOL LS2208, DS6067  EN ISO 17664 and ISO 17664

10.7 ECG module 12.3 CE declaration


 ECG lead port: 6 pin, IEC&AHA, for TE7 system is fully in conformance
with the Council Directive 93/42/EEC
3-lead wires Concerning Medical Devices. The
number adjacent to the CE marking
11 System Inputs and Outputs (0123) is the code of the EU-notified
 HDMI: 1 Port body that certified meeting the
requirements of Annex II excluding (4).
 ECG connector: 1 port of the Directive.
 USB: 4 USB 3.0 ports NOTICE:
 Ethernet: 1 port Not all features or specifications described
in this document may be available in all
12 Safety and Conformance
probes and/or modes.
12.1 Quality standards Mindray reserves the right to make
 ISO 9001 changes in specifications and features
 ISO 13485 shown herein, or discontinue the product
12.2 Design standards at any time without notice or obligation.
 EN 60601-1 and IEC 60601-1 Contact Mindray Representative for the
 EN 60601-1-2 and IEC 60601-1-2 most current information
 EN 60601-1-6 and IEC 60601-1-6

 EN 60601-2-37 and IEC60601-2-37

11
Mindray Confidential
Version 01.02.00 Oct. 2015