You are on page 1of 10

GA mismatches layout

LEGENDS: GA matches layout

Equipment Equipment Equipment


Unit Equipment Tag # Orientation Description type

0300 0305-01 Vertical FURNACE


0300 0305-02 Vertical FURNACE
0300 0305-12 Vertical FURNACE
0300 0306-30 Vertical REACTOR
0300 0307-51 Horizontal EXCHANGER
0300 0307-61 Horizontal EXCHANGER
0300 0307-52A/B/C Horizontal EXCHANGER
0300 0307-62 Horizontal EXCHANGER
0300 0106-68 Vertical KO pot VESSEL
0300 0106-07 Vertical VESSEL
0300 0306-01 Vertical VESSEL
0300 0307-53A/B/C Horizontal EXCHANGER
0300 0307-53D Horizontal EXCHANGER
0300 0306-43 Horizontal VESSEL
0300 0306-44 Horizontal VESSEL
0300 0306-45 Horizontal VESSEL
0300 0306-42 Vertical VESSEL
0300 0306-52 Vertical VESSEL
0300 0106-59X Vertical VESSEL
0300 1C-21 Vertical VESSEL
0300 8106-44X Vertical VESSEL
0300 6005-02
0300 0309-01/02 & 0109-01

0800 0806-01/02 vertical Vessel


0800 0806-03 vertical Vessel
0800 0827-01 vertical Vessel
0800 0806-13 horizontal Vessel
0800 0806-09 vertical Vessel
0800 0806-06 vertical Vessel
0800 0806-07 vertical Vessel
0800 0806-04 vertical Vessel
0800 0806-12 vertical Vessel
0800 0811-02
0800 0822-02
0800 0811-01
0800 0811-03
0800 0811-04
0800 0806-11

PUMPS
0300 6308-02 Vertical PUMP
0300 0308-17 Horizontal PUMP
0300 0308-14 Horizontal PUMP
0300 0308-01 Horizontal PUMP
0300 0308-02 Horizontal PUMP
0300 0308-05/06 Horizontal PUMP
0300 0308-07 Horizontal PUMP
0300 0308-03/04 Horizontal PUMP
0300 0308-15 Horizontal PUMP
0300 0108-36X/37X Horizontal PUMP
0300 0108-88X/89X Horizontal PUMP
0300 2608-20X/21X Horizontal PUMP
Diameter
(mm)
GA Document
GA Available GA Drawing company no. Matches with
Layout (9A9) GA layout

Yes Heurtey London L2W 5000 4902.2 NO


Yes Heurtey London L2W 4400
Yes BORN INC. 2262 4400
YES Robert Jenkins & Co. Ltd PO-60328 2500 2381.25 NO
YES AF CRAIG L35-0307-10 800 1241.43 NO
YES Industrie Mechannice CJ 4095/0023 - 1218
YES AF CRAIG 33359 1000 1250.95 NO
YES Industrie Mechannice CJ 4095/0023 - 1110
YES Procon L35-2822-01 1000 1219.2
YES G.Mangiarotti Job 119/72 1300 1249
YES Staveleys 3783/1 2500 2762.25 NO
YES Industrie Mechannice - 900 1092 NO
YES Industrie Mechannice - 900 1092 NO
YES Staveleys 3781/1 2000 2228.85 NO
YES Whiteley Dwg no 7012 1100 1241.43 NO
YES Staveleys 3781/1 1700 1857.375 NO
YES Gapper Niel A/2634 1000 797 NO
YES Woodall Deckham F/03/03-2/022256 1000 797 NO
YES Payne 1877-E 610 610 YES
YES Glapwell 3377/1 4638 4636 YES
YES 600 584 NO
NO

yes Neill & Son - 4000 4000 YES


yes Newbank - 800 889 NO
yes W. wild - 3000 3000 Yes
yes Pall Houston - 914 914.4 Yes
yes Fram Europe - 900 740 No
yes Beverley - 500 406 No
yes Newbank - 900 508 No
yes Hobal - 400 330 No
yes 600 597 No
250 406 No

300 406 No
250
750

YES Sundstrand 4729-8 600 660 NO


YES Amoco M/48-2/001417 W 900 W 900 YES
YES David brown GF B34089 W 1200 W 1118 NO
YES Procon GA-B 340085 W 1200 W 1016 NO
YES Procon GA-B 340084 W 1200 W 1118 NO
YES Procon GA B110321-2 W 1000/800 W 889 NO
YES Procon - W 1100 W 1130.3 NO
YES Procon - W 1500 W 1550 NO
YES Procon - W 1500 W 1550 NO
YES Procon - W 1200 W 1143 NO
YES Ingersoll - W 1000 W 840 NO
YES Amoco W 1010 W 1010 YES
Length/Height
(mm)

Layout Matches with


Length Type (9A9) GA layout

-
-

Head to Head 4100 4083.05 NO


Head to Head - 8282 -
Head to Head 8000 7889.88 NO
Head to Head - 8227

Head to Head 6200 6100 NO


Head to Head 6200 6115 NO
Tan to Tan 9000 9144 NO
Tan to Tan 3000 3048 NO
Tan to Tan 9000 9144 NO

NO

4052 3951.8 No
3500 1422 No

2000 2100 NO
4600 4693 NO
3500 4276.73
4100 4267.2 NO
2000 1651 NO
1500 1676.4 NO
3300/3322 3450 NO
3300 3450 NO
2400 2667 NO
1500 1900 NO
2040 2040 YES
Remarks

Used Procon Released for construction drawing. Circular dia taken


Dimensions not readable.
Dimensions not available.
Layout marked as 2500 mm,while GA's is 2381.25 mm.

placed above 0307-51 but layout dia doesn’t match. Should be placed instead of 0307-51 on layout.

placed above 0307-52c but layout dia doesn’t match.


Layout marked 1000 mm.

0307-53D should be placed on layout as it is 15 mm longer than 0307-53C

Mismatch,please refer MOM for drawing.


Mismatch,please refer MOM for drawing.
Package mismatches, Misaligned package 0806-08,0808-04/05

GA not found
GA not found
Filter pot,to be decided whether to remove from layout.

0308-05/06 are same but in layout,different dimensions.

0308-03/04 are same but in layout,different dimensions.


YES VESSEL Tan to Tan
NO EXCHANGER Head to Head
PUMP
REACTOR
FURNACE
Tan to Tan Vertical
Head to Head Horizontal

You might also like