CONTRACT No.

MADE BY: JCS CHCKD:


DATE: 3/1/2005 DATE:

DUMMY LEG & TRUNNION LOADING CALCULATION (S.I. UNITS)

PIPE SUPPORT No. 1

LINE NUMBER. 8"-P-1460-3CS1P2


G.A. No. 10188 d
STRESS Sk. No. 100-SK-001
NODE. No. 230 F1
L a
Elevation - detail no. 1
R
Elevation - detail no. 2

L
Fc
1
T nom.

t nom. L L

F1
F1
a
Fa a
Fa Elevation - detail no. 3

GEOMETRIC INPUT DATA:- Detail no. 1,2 or 3 = 3

Pipe Dia. mm = 219.1 Pipe radius (R) mm = 109.55

Pipe nom. thk (Tnom) mm = 15.06 Pipe tolerance % or = 12.5


Pipe tolerance (mm) = 0

Pipe corr. allw. (mm) = 3.2 Pipe min. thk (T) mm= 9.9775

Trunnion Dia (d) mm = 168.3 Trunnion radius (r) mm = 84.15

Pad nom. thk (tnom) mm = 0 Pad tolerance % or = 12.5


Pad tolerance (mm) = 0

Pad min. thk. (tp) mm = 0.000 Moment arm (L) mm = 450

Effective wall thickness for calculation (t) mm = T + tp = 9.978

Attachment 8 Page 1 of 2 564841335.xls


CONTRACT No. 0
MADE BY: JCS CHCKD:

DATE: 3/1/2005 DATE:

DUMMY LEG & TRUNNION LOADING CALCULATION (S.I. UNITS)

PIPE SUPPORT No. 1


LOADING INPUT DATA:
Design press. (P) bar = 113.8

Direct axial load (Fa) n = 13,000

Force producing longitudinal moment (Fl) n = 5,000

Force producing circumferential moment (Fc) n = 2,000


Max. vertical hydro-test load n = 14,000
CALCULATION: (USING KELLOGS METHOD)

fl = Fl · L / P · r² = 101.13 (longitudinal lineal load n/mm)

fc = Fc · L / P · r² = 40.45 (circumferential lineal load n/mm)

fa = Fa / 2 · P · r = 24.58 (direct lineal load n/mm)

f1 = 1.5( fc + fa ) = 97.55 f2 = 1.5 · fa + fl = 138.00

Circumferential bending stress (Sbc) = 1.17 · f1 · R= 37.91


t 1.5

Longitudinal bending stress (Sbl) = 1.17 · f2 · R= 53.62


t 1.5

Hoop primary stress (Sph) n/mm² = P · R / 10T = 124.95

Longt. primary stress (Spl) n/mm² = P · R / 20T = 62.47

Combined circ. stress (Sc) n/mm² = Sbc + Sph = 162.85

Combined long. stress (Sl) n/mm² = Sbl + Spl = 116.10

Allow. stress (Sh) n/mm² = 137.9 1.5 · Sh = 206.85 = Sha


Allow. stress (Scold) n/mm² 137.9
Sc and Sl to be less than 1.5 · Sh
Operating / design condition :-
This calculation shows the trunnion to be SATISFACTORY

Hydro-test condition :-
This calculation shows the trunnion to be SATISFACTORY

Attachment 8 Page 2 of 2 564841335.xls