You are on page 1of 3

1.

Any of the following answers: bidet,


2. Any of the following answers: 6" CHB,
3. Any of the following answers: blue,
4. Any of the following answers: 30-40,
5. Any of the following answers: water pressure regulator,
6. Any of the following answers: building sewer,
7. Any of the following answers: air chamber,
8. Any of the following answers: 2" dia,
9. Any of the following answers: aerobic treatment system,
10. Any of the following answers: lavatory faucet,
11. Any of the following answers: the pressure inside the pipe equates to the pressure
outside the pipe causing the water to stop at that point where it appears,
12. Any of the following answers: 2" dia,
13. Any of the following answers: 2" dia,
14. Any of the following answers: 1/4 of 1 ft,
15. Any of the following answers: X11.2,
16. Any of the following answers: siphon-jet,
17. Any of the following answers: gate valve,
18. Any of the following answers: 2" dia,
19. Any of the following answers: back vent pipe,
20. Any of the following answers: fusion welding,
21. Any of the following answers: siphon jet,
22. Any of the following answers: flow limiting feature,
23. Any of the following answers: soil pipe,
24. Any of the following answers: 2%,
25. Any of the following answers: potability (water),
26. Any of the following answers: yes ,
27. Any of the following answers: 3 m,
28. Any of the following answers: to use up the di erence in pressure from the
service to supply fixture,
29. Any of the following answers: X11.3,
30. Any of the following answers: check valve,
31. Any of the following answers: 2",
32. Any of the following answers: white,
33. Any of the following answers: aerator,
34. Any of the following answers: dental,
35. Any of the following answers: pipe chase,
36. Any of the following answers: drywall,
37. Any of the following answers: waste pipe,
38. Any of the following answers: A,
39. Any of the following answers: near the curb,
40. Any of the following answers: it should be underneath the driveway,
41. Any of the following answers: 4" closet bend,
42. Any of the following answers: pipe chase,
43. Any of the following answers: teflon,
44. Any of the following answers: pipe chase,
45. Any of the following answers: 1 per 25,
46. Any of the following answers: ceramic,
47. Any of the following answers: uPVC,
48. Any of the following answers: combined drain,
49. Any of the following answers: 38 mm,
50. Any of the following answers: C,
51. Any of the following answers: individual house pipes in connection with meter,
52. Any of the following answers: elbow,
53. Any of the following answers: B,
54. Any of the following answers: back vent,
55. Any of the following answers: 4",
56. Any of the following answers: gas pipe,
57. Any of the following answers: catch basin,
58. Any of the following answers: 1.80 m,
59. Any of the following answers: reinforced concrete,
60. Any of the following answers: G.I. pipe,
61. Any of the following answers: septic vault,
62. Any of the following answers: flushometer,
63. Any of the following answers: X11.6,
64. Any of the following answers: 3/4 S traps,
65. Any of the following answers: shock arrester,
66. Any of the following answers: 1 per 35,
67. Any of the following answers: chloride,
68. Any of the following answers: store waste in the tank and dispose in sanitary fill,
69. Any of the following answers: coupling,
70. Any of the following answers: 2",
71. Any of the following answers: the bigger the pipe diameter, the lesser the
pressure;
the smaller the pipe diameter, the greater the pressure is,
72. Any of the following answers: booster pump,
73. Any of the following answers: lead,
74. Any of the following answers: black,
75. Any of the following answers: schedule,
76. Any of the following answers: 60 psi,
77. Any of the following answers: 3" dia,
78. Any of the following answers: Sec. 4,
79. Any of the following answers: Sec. 5,
80. Any of the following answers: need approval of administrative authority,
81. Any of the following answers: Sept. 30, 1999,
82. Any of the following answers: the replacement of an electric water heater,
83. Any of the following answers: revised water usage/ classification water quality
criteria,
84. Any of the following answers: Revised E uent Regulation of 1990,
85. Any of the following answers: Phil. National Std. for Drinking Water 2007,
86. Any of the following answers: 1.7 m x 1.8 m,
87. Any of the following answers: 2.25 & 1500,
88. Any of the following answers: 450 mm,
89. Any of the following answers: 800 mm,
90. Any of the following answers: 480 mm,
91. Any of the following answers: 400 mm,
92. Any of the following answers: Php 7.00,
93. Any of the following answers: Php 2.00,
94. Any of the following answers: Php 4.00,
95. Any of the following answers: 20,
96. Any of the following answers: 1500 mm x 1500 mm,
97. Any of the following answers: 500 mm,
98. Any of the following answers: 460 mm,
99. Any of the following answers: BP 344,
100. Any of the following answers: 75,

You might also like