Programming Guide Entering the Manual Programming Mode

1. Press the SERVICE INFO button on the keypad.


2. Press the MOVE DOWN button several times until you see the
screen with the Menu Selection “To program mode Press 0”.
0 1 2 3 3. Press 0 (zero) button. The Main Menu screen appears.
. 4 5 6 4. If the password has been enabled, you will have to enter the correct
S 7 8 9 password.
Exiting the Manual Programming Mode
1. From the main menu screen, press the SERVICE INFO button on the
keypad to enter Run Mode. “SELECT CYCLE” appears.
CFD1329R
CFD1329R
Error Codes
20 Pound Through 125 Pound Models
(65 Liter Through 600 Liter Models) Display Description Cause/Action
 No Drain End Drain Failure; full stop + tumble

 Tilt Fault Safety switch activated; full stop + tumble

Safety switch activated during transition from


 Imbalance
distribution into spin sequence; skip + continue

 Tilt High Sp Out of balance: high spin; Full stop + safety time

 Door Switch Door switch failure; Full stop + safety time

 Door Coil Door lock switch failure; Full stop + safety time
CFD2995P  Door Start Door lock failure in beginning of cycle; Don’t start
180 Pound Through 275 Pound Models  Door Unload Door lock opening failure at end of cycle; Don’t start
(800 Liter Through 1200 Liter Models)
 No Fill Fill failure; Full stop + request for Continue

 Overfill Overfill failure; Full stop + tumble


Keypad Definitions  No Heating Heating failure; Full stop + tumble
Entering the Manual Programming Mode
Exiting the Manual Programming Mode  Heat Time Heating time failure; Full stop + request for continue
Error Codes  Too Hot Too hot; Full stop + tumble
Programmable Options  Overflow Water level too high; Full stop + tumble
Keypad Definitions  Level Sens. Defective level sensor; Continue + Don’t start
2 3 4 5 Defective temperature sensor; Continue + Don’t
6  Temp Sensor
start

Undefined frequency inverter error code; Full stop +


 Mitsub. Code
tumble

1 0 1 2 3
 Invert. Com. Communication fault inverter; Full stop + safety time
. 4 5 6 7
S 7 8 9  THT time ThT Time out; Full stop + safety time

 OV3/OP time OV3 time out / E.OP; Full stop + safety time

CFD1329R
 Load Parr Initialization fault frequency inverter; Don’t start
8
12 11 10 9 Verification fault frequency inverter parameters;
CFD1329R  Verify Parr
Don’t start
2 3 4 5
 Wrong Softw Wrong software version; Don’t start

Unbalance detection system activated; Reduction of


 Imbalance
spinning sequence revolutions. For info only
9
Drain failure at the spray sequence; Full stop +
 No Drain Spr
tumble
12
No Recycle (Front The tank with recycle water is empty; warning at
 Soap Dispenser
end
11 Machine only)

1 10 The soap supplies are running out of soap; For info


 Out of Soap only
8
6
CFD2995P
7 Service Due Warning; For info only; Open door =
 Service Due reset
CFD2995P
1 Info 7 Numeric keypad  Connection No Network Connection; For info only
2 Move up 8 Service info Wrong Voltage Range Selection; Make correct
3 Selection No 9 Start
 Voltage Par
selection
4 Selection Yes 10 Cancel the selection
Incorrect selection of machine type; Make correct
5 Stop 11 Confirm the selection (Enter)  Model Type
selection
6 Delayed start function 12 Move down
 Speed Sensor The drum rotation sensor is not working; Full stop +
tumble

August 2018 © Published by permission of the copyright owner - DO NOT COPY or TRANSMIT D1754R4
Error Codes Programmable Options
Display Description Cause/Action Menu Item Option Display Default Range
 Unload Speed Drum Speed too high during unloading process; Full External Wait
Off
No / Soap / Heating /
stop Control Wait Time

Incorrect signal for liquid detergent dispensing; Full Door Position


 Soap Time Out
stop + tumble Dirty Tune
5 0-9

 No Reheat Heating failure; Full stop + tumble Door Position


5 0-9
Hyg. Tune
 No Refill Refill failure; Full stop + request for continue
Prewash Soap
Yes No/Yes
No successful wash cycle termination; Info that the Info
 Power Interruption
wash cycle has to be repeated
Wash Liquid Soap
Yes No/Yes
Real Time Clock, no battery or battery power low; Info
 RTC Reset Bat
For info only
Main Water
High Low/Medium/High
Communication fault weighing system; Full stop Pressure
 Weigh No Comm
tumble
Step Info No No/Yes
 Weigh Low Weight machine is too low; Don’t start
2. Configuration
Machine Type FX65 List
 Weigh High Weigh machine is too high; Don’t start Menu

Weight is not balanced over 4 load cells; Reset Defaults No No/Yes


 Weigh Balance
Don’t start
Brightness Display 12 1-20
Weigh on individual load cell exceeds max;
 Weigh Overload
Full stop tumble Supply Voltage
(Inverter Type) n/a List
 Mits Err
Specific Mitsubishi Inverter Alarm; Full stop + safety
 time Load Param… No No/Yes

 Total No. of Inlets 2 2/3


Memory Err Memory Error; Full stop + safety time
 Drain Val. 1 No No/Yes
Inverted
TRACEYBILITY Internal memory error data for traceability;
 Write For info only Drain Valve 2 No No/Yes
TRACEYBILITY
 Full
Internal traceability memory is full; For info only Water Recycle
0 0/1/2/3
Inlets
 USB Errors
Errors in communication with USB flash disk; Supply Sign. A Box Box/Liquid
 For info only
Liquid Soap
 Supply No No/Yes
Softw. Err Software Error; Full stop + safety time

Min. Level Start 0 – Minimum progr.
0 units
Supply Level
Programmable Options Temperature Celsius C/F
Menu Item Option Display Default Range Full Heating 1% 1-100%

1. Programming Wet Cleaning No No/Yes


Language English List
Menu
Ultrabal. Settings 10 10/15
Service Interval 3000 1-9999
Non-barrier model No No/Yes
Buzzer Time 5 Sec 0-99
Erase All Wash No No/Yes
Allow Advance Yes No/Yes Prog?

Automatic Load Standard


No No/Yes No No/Yes
Cooldown Programs?

Wait for Language English List


Yes No/Yes
Temperature
Load Program
No No/Yes
Manual Override Yes No/Yes 1-20?

Temperature Load Program > No No/Yes


No No/Yes 20?
Balance

Motor On Time 12 Sec 1-99 Sec Communication 255 1-255


Addr.
Motor Off Time 3 Sec 1-99 Sec
3. Advanced Strict Temp.
No No/Yes
Smart Motion No No/Yes Menu Control

Hot Water Heater a. Hygienic Temp. Calib.


60°C 50-80°C 0 -5/0/5
Temp. Cycle Menu Offset

Temp. Overshoot Hygienic Water


0% 0-30% No No/Yes
Prot. Level

Max Heating Time 60 Min 10-90 Min b. Program


Mode Lock Password…. None 0000-99999
Max Water Fill Menu
10 Min 5-99 Min
Time
Edit Password… N/A N/A
Overfill Detection 5 units 3-25 units
c. Program Password….
None 0000-99999
Lock Menu

D1754R4 © Published by permission of the copyright owner - DO NOT COPY or TRANSMIT August 2018
Programmable Options Default Wash Programs
Menu Item Option Display Default Range Wash Program 1: Hot Wash Intensive 194°F [90°C]
Programs 1, 3-99 Unlocked Unlocked/Locked Wash Program 2: Warm Wash Intensive 140°F [60°C]
Program 2 Locked Unlocked/Locked
Wash Program 3: Colored Wash Intensive 104°F [40°C]
Edit Password…. N/A N/A
Wash Program 4: Bright Wash Intensive 86°F [30°C]
d. Traceability Enable
No No/Yes
Menu Traceability Wash Program 5: Woolens 59°F [15°C]
Traceability report Data DAQ Data DAQ/Data PC Wash Program 6: Hot Wash 194°F [90°C]
PC Comm. Wash Program 7: Warm Wash 140°F [60°C]
15 sec 0-999 sec
Timeout

PC Data Time Wash Program 8: Colored Wash 104°F [40°C]


Limit 60 sec 0-999 sec
Wash Program 9: Bright Wash 86°F [30°C]
Disable
No No/Yes
Traceability Errors Wash Program 10: Eco Hot Wash 194°F [90°C]
e. Weighing Weighing System No No/Auto/Manual Wash Program 11: Eco Warm Wash 140°F [60°C]
Menu

Main units Kg Kg/%


Wash Program 12: Eco Color Wash 104°F [40°C]

Help units % %/kg/vypnuto Wash Program 13: Eco Bright Wash 86°F [30°C]
Load Cell
N/A N/A
Wash Program 14: Extraction - Low Speed
Calibration…
Wash Program 15: Extraction - High Speed
Expected Free
Weight XXXX 0-9999
Wash Program 16: Sport 140°F [60°C]
Water Level Units Units/Litres
Wash Program 17: Mops 140°F [60°C]
Correct Linen
No No/Yes Wash Program 18: Horse Cloths 104°F [40°C]
Absorpt.

Automatic Level
No No/Yes Wash Program 19: Jeans 140°F [60°C]
Adjust.
Wash Program 20: Starching
Automatic Soap No No/Yes
Adjust.
NOTE: Refer to full Programming Manual for detailed
Scale Stabilization 3 3-15 information about individual wash programs.
Calibration 100 80-120
coefficient

f. Tilting Tilting system


Off Off/1/2
System Menu

Stabilization Time 25 10-300 sec

g. Data Export/
Import Menu Data Export No No/Yes

Programs Import No No/Yes

Conf. Import No No/Yes

h. Special
Menu SoapLink Comm No No/Yes

NOTE: Refer to full Programming Manual for additional programming


features.