Technical Article
BGA Repair:
A Better Understanding can Reduce Fears,
Guarantee Process Control and Save Money
by Mark Cannon
ERSA GmbH
06.08.2001.ca-dy BGArework_e.indd Page 1
ERSA Know-How Transfer
BGA Repair
Let us examine the key considerations Uniform heat distribution and transfer that has prematurely reached reflow. If
during the reflow process. See fig. 3. across the entire surface of the area the process is stopped at this point, the
array package and its land pattern on component will not lower itself uniformly,
Uniform heat distribution and transfer the PCB is critical. The heating pro- is not coplanar and therefore is insuf-
across the entire surface of the area cess and thermal profile must attempt ficiently soldered. In addition, a critical
array package and its land pattern on to cause the package to reach reflow consideration for the extremely small
the PCB is critical. The heating pro- and uniformly „drop“ or lower itself to and lightweight CSP/Flip Chip compo-
cess and thermal profile must attempt the lands as the balls melt and form nents (see Figure 7) is the airflow rate
to cause the package to reach reflow an intermetallic with the pads. See in the convection reflow ovens. While
and uniformly „drop“ or lower itself to Figure 4 showing an optical picture a minimum air flow rate is required to
the lands as the balls melt and form using the patented ERSAScope, X-ray transfer the heat to the component and
an intermetallic with the pads. See image and a cross-section of a profes- PCB, this rate must not allow these light
Figure 4 showing an optical picture sionally installed PBGA. Note how the components to be either blown away
using the patented ERSAScope, X-ray component has dropped, is parallel to or to move during the reflow process.
image and a cross-section of a profes- the PCB, and how all balls are uniform When the extremely small eutectic balls
sionally installed PBGA. Note how the in shape and are completely „wetted“ or are in a liquid state, any movement can
component has dropped, is parallel to soldered to the land. cause the surface tension and „support“
the PCB, and how all balls are uniform function of the balls to be disrupted
in shape and are completely „wetted“ or Non-uniform heating, on the other hand, resulting in the CSP dropping comple-
soldered to the land. would cause the package to unevenly tely onto the board during reflow.
drop or tilt towards the side or corner
Figure 4: An ERSAScope Image, X-ray image and cross-section of a professionally installed PBGA.
ERSA GmbH
Page 2 BGArework_e.indd 06.08.2001.ca-dy
ERSA Know-How Transfer
BGA Repair
ERSA GmbH
06.08.2001.ca-dy BGArework_e.indd Page 3
ERSA Know-How Transfer
BGA Repair
ERSA GmbH
Page 4 BGArework_e.indd 06.08.2001.ca-dy
ERSA Know-How Transfer
BGA Repair
Mark Cannon
President
Soldering Tools & Insection Systems,
ERSA GmbH, Wertheim, Germany
e-mail: info@ersa.de • www.ersa.com