step 1 C-25 concrete and S-300 steel grade ,Le=Lx for Ly>Lx
panel Boundary condition types of slab system Lx Ly
p1 type 4 two way 5 6 p2 type 2 two way 4 6 p3 type 2 two way 5 6 p4 type 2 two way 5 6 p5 type 2 two way 4 6 p6 type 4 two way 5 6 p7 type 2 two way 4 5 p8 type 1 two way 4 4 p9 type 1 two way 4 5 p10 type 1 two way 4 5 p11 type 1 two way 4 4 p12 type 2 two way 4 5 p13 type 3 two way 5 6 p14 type 2 two way 4 6 p15 type 1 two way 5 6 p16 type 1 two way 5 6 p17 type 2 two way 4 6 p18 type 4 two way 4 5 p19 type 4 two way 4 5 p20 type 4 two way 4 5 p21 type 7 two way 4 5 00 steel grade ,Le=Lx for Ly>Lx
Span ratio Ly/Lx types of support condition Ba
1.2 End span 38 1.5 Interior 40 1.2 Interior 43 1.2 Interior 43 1.5 Interior 40 1.2 End span 38 1.25 Interior 42.5 1 Interior 45 1.25 Interior 42.5 1.25 Interior 42.5 1 Interior 45 1.25 Interior 42.5 1.2 End span 38 1.5 Interior 40 1.2 Interior 43 1.2 Interior 43 1.5 Interior 40 1.25 End span 37.5 1.25 End span 37.5 1.25 End span 37.5 1.25 End span 37.5 d=0.85(Lx/ Ba) m 0.111842105263158 0.085 the governing depth is t 0.098837209302326 0.098837209302326 0.085 0.111842105263158 0.08 0.075555555555556 0.08 0.08 0.075555555555556 0.08 0.111842105263158 0.085 0.098837209302326 0.098837209302326 0.085 0.090666666666667 0.090666666666667 0.090666666666667 0.090666666666667 the governing depth is the max one i.e 112mm
OVER ALL DEPTH D=dmax+15mm+ᶲ/2=112mm+15mm+10mm/2=132mm<D cal=150mm O.K