Specification of Stack
Summary
Parameters %O2 % CO2 CO NO NO2 NOx as NO2 SO2 %CE
Average of (ppm) 14.2 6.9 72.8 528.0 7.1 535.1 0.0
Concentrations (mg/Nm³) - - 83.3 647.9 13.3 1006.6 0.0 99.90
Oxygen correction result (mg/Nm³) - - 98.2 763.6 15.6 1186.5 0.0
*) %CE : Combustion Efficiency
Component
Volume of gas sampled through dry gas meter (Vm) 0.865 m³
Dry gas meter (DGM) calibration factor (Y) 0.9965
DGM temperature in Celsius (tm) 35.0 °C
DGM temperature in Kelvin (Tm) 308.0 K
Temperature Standard (Tstd) 298.0 K
DGM orifice pressure differential (dH) 49.25 mmH2O
Barometric pressure actual (Pbar) 758 mmHg
Barometric pressure standard (Pstd) 760 mmHg
Gas Ideal a Constant (R) 0.06236 mmHg.m³/g-mol.K
Weight Molecular of Water M 18 g/mol
Component
Volume of dry gas sampled convert to STD Condition Vm(std) 0.8410 Nm³
Volume of condensed water vapor convert to STD Condition Vwc(std) 0.08 Nm³
Volume of condensed water vapor in silica gel convert to STD Condition Vwsg(std) 0.00679 Nm³
Mole Fraction of water vapor condensed Bws 0.090 (v/v)
Water Content %H2O 9.0 %(v/v)
METRIC UNITS
PT SUCOFINDO
Determination of Linier Velocity, Molecullar Mass of Dry Gas and Total Particulate
Client PT. HM SAMPOERNA PLANT SUKOREJO Technician SJD/WY/MMA
Unit GENSET 01 (213378-26) Start Time 14:00
Date of sampling MAY 29,2021 14.00 wib End Time 15:00
Metode SNI 7117.14-2009 (Linier Velocity) Lab No 0
SNI 7117.15-2009 (Molecullar Mass of Dry Gas)
SNI 7117.17-2009(Total Particulate)
STACK DATA EQUIPMENT ESTIMATES FILTERS
% H2O est (%)O₂
% Moisture est: 5 METER BOX: Est. Tm: 35.0 °C Main Filter (g) Recovery (g)
CORRECTION
Barometric: 758.0 mm Hg Y: 0.9965 Est. Ts: 394.0 °C W1 0.3372 1.4034 REFERENCE
Static Press: 42.8 mm H2O DH@: 47.30 mm H2O Est. dP: 76.5 mm H2O Wo 0.3262 1.401
Stack Press: 761.1 mm Hg PITOT: Est. Dn: 4.80 mm W1-Wo 0.011 0.0024 13
%CO2: 6.93 % Cp: 0.84 LEAK CHECKS K FACTOR
%O2: 14.21 % NOZZLE: DGM initial ______ ______ ______ liters
0.61
%N2/CO: 78.86 % Dn: 4.80 mm DGM final ______ ______ ______ liters
Md: 29.68 g/g-mole Diameter Stack 0.5 m Leak Rate ______ ______ ______ lpm Particulate Mass (mg)
Ms: 29.09 g/g-mole Traverse Point 8 Vacuum ______ ______ ______ in. Hg 13.4
Sample Time Pitot Gas Temperatures (°C) Orifice Press. Pump Gas Temps
Sample
DP (H2O) DH (H2O)
RESULTS
Signature : Signature :
METRIC UNITS
REPORT OF ANALYSIS
Test Result
Threshold Limit
Parameter Unit Measurement Corrected Methods
Value
Concentration Concentration
mg/Nm³ 16.0 18.9 150 SNI 7117.17:2009
Total Particulate
SO₂ (Sulfur Dioxide) mg/Nm³ <0.26 <0.26 800 PO/ENV-EMS/02
Nitrogen Oxide (NOx) as NO₂ mg/Nm³ 1007 1186 1000 PO/ENV-EMS/03
CO (carbon Monoxide) mg/Nm³ 83.3 98.2 600 SNI 19-7117.10-2005
CO₂ (Carbon Dioxide) % 6.93 - - SNI 19-7117.10-2005
O₂ (Oxygen) % 14.21 - - SNI 19-7117.10-2005
Isokinetic % 94.7 90 - 110 Calculated
Linear Velocity m/s 47.4 - SNI 7117.14:2009
Flow Rate (ACT) m³/s 9.3 - SNI 7117.14:2009
Flow Rate (STD) m³/s 3.5 - SNI 7117.14:2009
Note : The result of parameter concentration were corrected 13% oxygen rate on condition normally air (25°C and 1 atm) and dry basis